lancelot 27' - empirecommunities.r.worldssl.net · lancelot 27' opt. door where grade...

2
STYLE C – 1667 SQ.FT. STYLE B – 1658 SQ.FT. STYLE A – 1657 SQ.FT. LANCELOT 27'

Upload: lekhuong

Post on 16-Sep-2018

227 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LANCELOT 27' - empirecommunities.r.worldssl.net · lancelot 27' opt. door where grade permits (additional steps as req'd) built -in bench additional steps as req'd by grade (location

STYLE C – 1667 SQ.FT.STYLE B – 1658 SQ.FT.

STYLE A – 1657 SQ.FT.

LANCELOT 27'

Page 2: LANCELOT 27' - empirecommunities.r.worldssl.net · lancelot 27' opt. door where grade permits (additional steps as req'd) built -in bench additional steps as req'd by grade (location

LANCELOT 27'

OPT. DOOR WHEREGRADE PERMITS

(ADDITIONAL STEPSAS REQ'D)

BUILT -IN BENCH

ADDITIONAL STEPS ASREQ'D BY GRADE

(LOCATION MAY VARY)

FOYER

10'-5" x 20'-5"GARAGE

PORCH

P.R.

MIRRORED SLIDERS

6' PATIO DOOR

UP

DN

DW

FLUSH BREAKFAST BAR

F

S

RAILING

OP

T. G

AS

FIR

EP

LAC

E

10'-9" x 9'-0"KITCHEN

BREAKFAST8'-11" x 9'-0"

19'-8" x 11'-5"GREAT ROOM

(STE

P IF

RE

Q'D

)

(STE

P IF

RE

Q'D

)

DN

10'-5" x 10'-5"BEDROOM 2

W D

13'-5" x 15'-0"

MASTERBEDROOM

OP

EN

TO

BE

LOW

SOAKERTUB

SHOWER

MASTERENSUITE

W.I.C.

T

LAUNDRY

MAIN BATH

LIN

ENR

AIL

ING

9'-0" x 10'-4"BEDROOM 3

UNFINISHEDBASEMENT

UNEXCAVATED

OPT.COLD CELLARUNEXCAVATED

LOWHEADROOM(IF REQ'D)

UP

OPT. 3-PCROUGH-IN

BATH

MECHANICALAREA

STYLE A – 1657 SQ.FT.STYLE B – 1658 SQ.FT.STYLE C – 1667 SQ.FT.

BASEMENT PLAN

STYLE A

GROUND FLOOR PLANSTYLE A

SECOND FLOOR PLANSTYLE A

All illustrations are artist's concept. Specifications, terms, prices and conditions are subject to change without notice. Actual usable floor space may vary from the stated floor area. These floorplans and room dimensions apply to style 'A' of this model type and may vary according to style. Please see New Home Sales Consultant for details. Location of furnace, hot water tank and support posts and beams are determined by the HVAC designer and architect respectively. Number of exterior steps may vary depending on the lot and the grading of individual home sites. E. & O.E. December 2017. 27-04

MUDROOM

All renderings and illustrations are artist’s concept. Specifications, terms, prices and conditions are subject to change without notice. Actual usable floor space may vary from the stated floor area. These floorplans and room dimensions apply to style ‘A’ of this model type and may vary according to style. Please see Sales Representative for details. Location of furnace, hot water tank and support posts and beams are determined by the HVAC designer and architect respectively. Number of exterior steps may vary depending on the lot and the grading of individual home sites. E. & O.E. January 2018. 27-04