Page 1: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

Michael Wollny Director, Business Development Off-Grid Solutions

SMA Solar Technology AG, Germany

BSW-Solar special exhibition

"Rural Electrification" at Intersolar 2011

Large Scale Off-Grid PV-Power Supply with Renewables

Page 2: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

2

Disclaimer

This presentation may contain future predictions. Future predictions are statements that do not describe facts from the past. They also contain assessments on our assumptions and expectations. These assessments are based on planning, estimates, and forecasts, which are currently available to the SMA Solar Technology AG (SMA or company) board of directors. Future predictions are therefore only applicable on the day on which they are made. It lies in the nature of future predictions that they contain risks and elements of uncertainty. Various known and unknown risks, uncertainties, and other factors may cause the actual results, financial situation, development, or performance of the company to significantly deviate from the assessments provided in this presentation. These factors include those that SMA has described in published reports, which are available on the website www.SMA.de. The company assumes no liability for updating or adjusting such future predictions in accordance with future events or developments.

This presentation serves informational purposes only and does not constitute an offer or request to buy, keep, or sell company shares.

Page 3: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

Outline

» SMA Solar Technology, Company introduction

» Market Potential Off-Grid

» Economical aspects

» Suitable technological solutions

» Best practices

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 4: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

SMA is market and technology leader for PV inverters

SMA offers inverters for all applications in photovoltaics

On-grid From <1 kW

To >1 MW

Thin film

Crystalline modules

Concentrator modules

Back-up

Off-grid

All PV applications All performance ranges All module types

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 5: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

8

Continuous internationalization in order to take over key positions in all future solar markets

More than 900 sales and service personnel all over the globe

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 6: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

7

SMA will benefit from the worldwide growth of the solar market due to the good market positioning

In 2010, SMA achieved nearly 45 % in sales abroad.

> Founded in 1981

> Turnover of 1.9 billion Euros in 2010

> 7.8 gigawatt produced in 2010

> More than 5,000 employees all over

the globe, approx. 330 trainees

> 17 foreign subsidiaries on four continents

> Best efficiency worldwide (98.7 %)

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 7: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

7

Source: SMA/Navigant Consult

Estimated Off-Grid Market Size in 2011

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 8: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

8

Estimated Off-Grid Market Size in 2011

Source: SMA/Navigant Consult

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 9: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

9

Sustitution of Diesel Generation Power with Renewables

Source: SMA

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 10: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

10

Estimated costs by using diesel generator » The electricity cost ranges between 0.30 Euros (dark brown) to 2.4 Euro (light yellow)

» The computations have been performed in three main steps.

- Calculation of transport costs for diesel; - Calculation of production cost for electricity - Calculation of the final costs of electricity consist of the production costs and the costs of labour, maintenance and amortization.

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 11: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

The electricity production cost calculated for a 15 kWp off-grid PV System in Africa

» The electricity production cost ranges from 0.2 up to 0.55 EUR/kWh

» Large geographical differences can be observed: some of the most favorable regions with low costs have very low population density (e.g. Sahara with 0-15 persons/km2) while at other are relatively densely populated (e.g. Tanzania, South Africa with 30-100 persons/km2 ))

11

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 12: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

Analysis of sensitivity: Benefits of PV Hybrid Systems

» With state-of-the-art PV-system costs as well as diesel fuel prices, a 30 kW PV hybrid system is approx. 20 % cheaper (regarding TCO)

» Above diesel fuel costs of approx. 0,8 €/l, the PV hybrid system will stay more cost effective

» With another decrease of PV system costs to half of today‘s price level, the costs of a PV hybrid system will only be 50 % of the costs for a full diesel power supply.

12

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 13: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

13

System technology – depending on size, the right concept has to be chosen

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 14: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

14

Suitable technological solutions for rural electrification

1. Grid extension for urban areas (AC bus line)

2. Genset dominated supply (Petrol, Gasoline, LPG)(AC bus line)

3. Solar Home Systems (DC-Bus line)

4. Hybrid or Mini Grid power supply systems based on Renewables (AC bus line)

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 15: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

15

Modular hybrid design

» Grid quality electricity » Easy expandability » Backup solution » Integration of different RES » Standard components

Inverter

AC bus line ~ =

~ =

~ =

Master Inverter

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 16: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

16

SMA Multicluster Technology

» Easy set-up for hybrid systems and mini-grids

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 17: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

17

Multicluster Box 6 Number of Sunny Island: 6 Load connection: 55 kW Multicluster Box 12 Number of Sunny Island: 12 Load connection: 110 kW Multicluster Box 36 Number of Sunny Island: 36 Load connection: 300 kW

SMA Multicluster Technology

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 18: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

18

SMA Multicluster Technology

» Approved technology for rural electrification and mini grids » AC-coupled hybrid systems » Outstanding flexibility and use of different renewable energy sources » High security of energy supplies and availability » Special knowledge for proper installation not needed

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 19: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

19

» Modular system configuration up to 300 kW » Use of standard components (Mulicluster Box, SI5048, SB, SMC, BATFUSE) » Comfortable transport to remote areas » Quick installation and commissioning

SMA Multicluster Technology

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 20: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

20

Hierarchy and communication links in the cluster group

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 21: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

21

Off-Grid Power Supply Isle of Eigg, Scotland

» Scottish Inner Hebrides

» 16 km distance to the coast

» Harboring around 100 residents

» The community consists of 45 households, 26 business and 6 community buildings

» Up to 2008: diesel supply during the day (reason was, noise protection)

... and in the evening candle light!

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 22: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

22

System control 100 kWp

(12 x SI5048)

Hydro power 110 kW

Wind Energy 24 kW (4 x WB6000)

Photovoltaic 10 kWp (3 x

SB3000)

Interconnection of different Renewable Energy

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 23: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

23

Micro-Grid: Distributed Renewable Energy Supply System

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 24: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

24

System Control over 3 parameter only

1. Frequency Shift Power Control

2. Voltage vs. Reactive Power

3. Battery State of Charge

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 25: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

» Frequency depending power control (FSPC, Frequency Shift Power Control), if battery is full and more renewable energy is available.

f= 50 Hz

Low energy consumption

Charged battery High penetration from renwables

f= (50+∆f) Hz

25

Variable No 1: System Frequency

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 26: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

» Similar to the grid interconnection without additional communication wiring » Output power control from PV and Wind with grid frequency » Increasing of system frequency results in declining of feeding from the inverters

Pac (%)

Fac (Hz)+ 1 + 2 + 3-1-2-3 f0

50

100

Fac-Start delta (1Hz)

Fac-Limit delta (2Hz)

+ 4

Fac-delta+ (4,5Hz)

-4

Fac-delta- (4,5Hz)

26

Frequency Shift Power Control

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 27: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

» Parallel operation of voltage sources desired droop control

27

UBWR UGEN

Variable No 2: Voltage vs. Reactive Power

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 28: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

» Sunny Island monitor and controls the system automatically

» Integrated Parameter: State of charge (SOC)

1. SOC 60 %: Generator is started

2. SOC 90 %: Generator is stopped

28

Diesel Generator is only needed if renewables are not available !

Variable No 3: State of Charge

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 29: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

29

» Electrification of 4 villages in the Region of Gardez, Afghanistan

» System with 100 kWp Photovoltaic and 250 kW - Diesel Generator

» 14 km medium voltage grid between the villages

» Prepaid-card system installed to cover the maintenance cost

Systems deliver energy in network quality !

Source: G

oogle Maps

Source: S

ES

A

A

Village Electrification – Afghanistan

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 30: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

30

» Electrification of over 250 schools in Malaysia

» Total power > 2 MW (PV-Systems from 15 to 60 kW)

» Substitution of 100 % Diesel Generator power

» Financed from the government over avoided diesel fuel costs

PV-Hybrid Systems are profitable

by now !

Source: G

oogle Maps

Source: S

MA

/Solarw

orld/AP

EX

Electrification of Schools – Borneo

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 31: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

31

South Pacific (Tahiti) Reao

» 18 x Sunny Island 5048 battery inverters: 90 kW

» Battery bank: 1842 kWh

» Photovoltaic: 140 kWp

» Diesel Generator: 120 kVA

» 1 x Multicluster Box 36.3

24 h power from batteries

» Power supply for 40 houses and business

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 32: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

Installed Multicluster Systems up to 300 kW

32

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 33: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

33

Conclusion and Outlook

Large-scale modular hybrid system

» with standard components are reliable and economical

» loads & generation coupled by a medium or low voltage grid

» Controlled by grid frequency and SOC

» high reliability achieved by using a modular concept

» easy service performed by local electricians

» PV hybrid systems are the only sensible way for remote habitations to guarantee a 24/7 power supply!

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion

Page 34: Large Scale Off-Grid PV-Power Supply with Renewables · The electricity production cost calculated for a 15 kWp off-grid PV System in Africa » The electricity production cost ranges

34

[email protected]

Dipl.- Ing. Michael Wollny SMA Solar Technology AG

www.SMA.de

Thank you very much for your attention !

More information you get from:

http://www.ruralelec.org/

Outline| Company Introduction| Potential Market| Economical aspects | Suitable technological solutions| Best practices | Conclusion