lasers for life sciences - coherent, inc. · 2021. 1. 12. · life science is important to improve...

138
Superior Reliability & Performance Lasers for Life Sciences 2015 Laser Overview

Upload: others

Post on 08-Mar-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Superior Reliability & Performance

Lasers for Life Sciences2015 Laser Overview

Page 2: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Applications:• Flow Cytometry • Confocal Microscopy• Genomics• Proteomics• Medical Diagnostics• Environmental Monitoring

Lasers for Life Sciences Overview of Laser Applications

Flow Cytometry MPE Imaging Medical Diagnostics

www.Coherent.com • [email protected] Reliability & Performance •

Page 3: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

1

Lasers for Life Sciences Overview of Laser Applications

Confocal Microscopy Medical Instrumentation DNA Sequencing

Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

As one of the fastest growing segments for laser-based solutions, Life Sciences covers a broad range of applications from scientific research leading to medical advances, to clinical functions where lasers are used in diagnostics.

Life science is important to improve our collective health and well-being, and providing the technology that is vital to the advancement of medicine is a major focus of Coherent’s life sciences strategy.* Our lasers enable advances in life sci-ence research and clinical and medical applications such as flow cytometry and cell sorting, microscopy, DNA sequenc-ing and retina scanning. Lasers are predominantly used in these applications to excite fluorophores attached to a sam-ple, allowing researchers and clinicians to perform a variety of important tests at both the cellular and molecular level.

Lasers for these applications are as varied as the instrument devices themselves, and span the spectrum from continuous- wave diode or optically pumped semiconductor lasers (OPSL) to ultrafast titanium:sapphire systems. It is our mission to enable new laser based applications taking advantage of a leadership in innovation.

* Wedonotincludemedicaltherapeuticproceduresin“LifeSciences”andhavenotincludedourportfolio oflasersfortherapeuticssuchashighpowerOPSL,semiconductororCO2lasersinthisbrochure.

Page 4: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

With nearly 50 years of experience in life sciences, Coherent understands that getting the best results requires a laser that perfectly matches your instrument in terms of wavelength, output power, beam quality, output noise, and budget. That’s why we offer the industry’s widest choice of laser technologies and performance options.

So, whether your challenge is in cutting edge research or developing a cost-sensitive clinical instrument, you can be sure you’ll find the perfect laser for your needs in the following pages.

2

Ultimate Choice.Perfect Match.

Sapphire

OBIS LG

Coherent offers a variety of laser platforms to allow you the freedom to choose.

You have the choice, in the coming pages, to select your product by wavelength, power, features or application.

Coherent makes it easy for you to optimize the laser to the work being accomplished… the perfect match for value and performance.

www.Coherent.com • [email protected] Reliability & Performance •

Page 5: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

3

Ultimate Choice. Perfect Match.

BioRay

OBIS LX, OBIS LS

Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 6: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Flow Cytometry:• OBIS LX, OBIS LS and Sapphire lasers for visible wavelengths (375 nm to 785 nm) • OBIS LG for 355 nm in the UV • BioRay for stable, cost-effective compact systems • Genesis CX for 355 nm in the UV, high power

Medical Diagnostics:• OBIS LX, OBIS LS and Sapphire lasers for visible wavelengths (375 nm to 785 nm) • OBIS LG for 355 nm in the UV • BioRay for stable, cost-effective compact systems

Confocal Microscopy:• OBIS LX for high speed modulation • OBIS Fiber Pigtailed for Single-mode Polarization Maintaining fiber delivery • OBIS LS and Sapphire for 458 nm to 594 nm

Medical Instrumentation:• OBIS LX, OBIS LS and Sapphire lasers for visible wavelengths (375 nm to 785 nm) • OBIS LG for 355 nm in the UV • BioRay for stable, cost-effective compact systems

DNA Sequencing:• OBIS LX for 660 nm • OBIS LS, OBIS LG or Sapphire for 532 nm

Multiphoton Excitation (MPE): for MPE applications, please refer to our Chameleon Ti:Sapphire Lasers beginning on page 116 of this Guide.

4

Ultimate Choice. Perfect Match.Choose Your Laser by Application

www.Coherent.com • [email protected] Reliability & Performance •

Page 7: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

5

Continuous-Wave (CW):

Modulation: Analog to 500 KHz

Modulation: Analog to 100 KHz and/or Digital to 50 KHz

High Speed Modulation: Analog to 500 KHz and/or Digital to 150 MHz

Fiber Delivery (Fiber Pigtailed): Single-Mode Polarization-Maintaining Fiber

Single Frequency (Longitudinal Mode)

OPSL (Optically Pumped Semiconductor Laser)

Adjustable Beam Divergence (User Adjustable Lens)

Compact Laser with common beam, common footprint, common interace, common accessories

6-Laser Remote, either power Remote and Scientific Remote

Beam Combining with OBIS Galaxy

Laser Box for 5-Laser integration with thermal management (cooling), Analog/Digital I/O and laser safety features

BioRay, OBIS LS, OBIS LX, Sapphire, OBIS LG, Genesis CX

BioRay

OBIS LS

OBIS LX

OBIS LX, OBIS LS, Sapphire

Sapphire SF

OBIS LS, Sapphire, OBIS LG, Genesis CX

BioRay

OBIS LX and OBIS LS

OBIS LX and OBIS LS

OBIS LX with UFC Connector. Optional OBIS LS and Sapphire with UFC conversion

OBIS LX and LS (frequently purchased with OBIS Galaxy)

Ultimate Choice. Perfect Match.Choose Your Laser by Features

Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 8: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

6

Ultimate Choice. Perfect Match.Choose Your Laser by Wavelength

355 nm OBIS LG at 20 mW

375 nm OBIS LX at 16 and 20 mW

405 nm OBIS LX at 50, 100 and 200 mW. OBIS LX Fiber Pigtailed at 50 and 100 mW. BioRay at 50 mW.

422 nm OBIS LX at 100 mW

445 nm OBIS LX at 75 mW. OBIS LX Fiber Pigtailed at 45 mW.

450 nm BioRay at 50 mW

458 nm OBIS LX at 75 mW. OBIS LX Fiber Pigtailed at 45 mW. Sapphire at 20, 50 and 75 mW. Sapphire FP at 40 mW.

473 nm OBIS LX at 75 mW. OBIS LX Fiber Pigtailed at 50 mW.

488 nm OBIS LX at 50 and 150 mW. OBIS LX Fiber Pigtailed at 30 and 100 mW. OBIS LS at 20, 60, 80, 100 and 150 mW. OBIS LS Fiber Pigtailed at 20, 60, 80 and 120 mW. BioRay at 20 mW. Sapphire at 10, 20, 25, 30, 40, 50, 75, 100, 150, 200 and 300 mW. Sapphire Fiber Pigtailed at 40, 80, 120 and 200 mW. Sapphire Single Frequency at 20, 50 and 100 mW.

505 nm OBIS LX at 50 mW. OBIS LX Fiber Pigtailed at 40 mW.

514 nm OBIS LX at 40 mW. OBIS LX Fiber Pigtailed at 30 mW. OBIS LS at 20 mW. OBIS LS Fiber Pigtailed at 15 mW. Sapphire at 20, 50, 75, 100 and 150 mW. Sapphire Fiber Pigtailed at 40, 80 and 120 mW.

520 nm OBIS LX at 40 mW. BioRay at 50 mW.

514 nm

458 nm

445 nm

488 nm

473 nm

505 nm

405 nm

422 nm

375 nm

355 nm

520 nm

450 nm

www.Coherent.com • [email protected] Reliability & Performance •

Page 9: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

532 nm OBIS LG at 1W. OBIS LS at 20, 50, 80, 100 and 150 mW. OBIS LS Fiber Pigtailed at 40, 60, 80 and 120 mW. Sapphire at 20, 50, 75, 100, 150, 200 and 300 mW. Sapphire Fiber Pigtailed at 40, 80, 120 mW. Sapphire Single Frequency at 20, 50, 100 and 150 mW.

552 nm OBIS LS at 20, 60, 80, 100 and 150 mW. OBIS LS Fiber Pigtailed at 15, 40, 60, 80 and 120 mW. Sapphire at 50, 75, 100, 150 and 200 mW. Sapphire Fiber Pigtailed at 40, 80 and 120 mW.

561 nm OBIS LS at 20, 50, 80, 100 and 150 mW. OBIS LS Fiber Pigtailed at 40, 60, 80 and 120 mW. Sapphire at 20, 50, 75, 100, 150, 200 and 300 mW. Sapphire Fiber Pigtailed at 40, 80, 120, and 200 mW.

568 nm Sapphire at 50, 75, 100, 150 and 200 mW.

588 nm Sapphire at 20, 50, 75 and 100 mW. Sapphire Fiber Pigtailed at 40 mW.

594 nm OBIS LS at 20 and 60 mW. OBIS LS Fiber Pigtailed at 40 mW. Sapphire at 20, 50 and 75 mW. Sapphire Fiber Pigtailed at 40 mW.

637 nm OBIS LX at 140 mW. OBIS LX Fiber Pigtailed at 100 mW.

640 nm OBIS LX at 40 and 100 mW. OBIS LX Fiber Pigtailed at 75 mW. BioRay at 40 mW.

647 nm OBIS LX at 120 mW. OBIS LX Fiber Pigtailed at 100 mW.

660 nm OBIS LX at 100 mW. OBIS LX Fiber Pigtailed at 75 mW.

685 nm OBIS LX at 40 mW

730 nm OBIS LX at 30 mW

785 nm OBIS LX at 50 mW

7

Ultimate Choice. Perfect Match.Choose Your Laser by Wavelength

785 nm

730 nm

660 nm

685 nm

647 nm

588 nm

561 nm

568 nm

552 nm

532 nm

640 nm

594 nm

637 nm

Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 10: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS LG: 20 mW

OBIS LS: 20 mW to 100 mW

OBIS LX: 16 mW to 200 mW

OBIS FP: 15 mW to 100 mW

BioRay: 20 mW to 50 mW

Sapphire LP: 10 mW to 300 mW

Sapphire SF: 20 mW to 150 mW

Sapphire FP: 40 mW to 200 mW

8

Ultimate Choice. Perfect Match.Choose Your Laser by Output Power

www.Coherent.com • [email protected] Reliability & Performance •

Page 11: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Ultimate Choice.Perfect Match.

9

Coherent offers a variety of laser platforms to allow you the freedom to choose. The following pages provide the details of the OBIS LG, OBIS LX, OBIS LS, BioRay, Sapphire and Accessories.

Coherent has made it easy for you to optimize the laser to the work being accomplished… the perfect match for value and performance.

Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 12: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Overview of Laser Applications 1

Ultimate Choice. Perfect Match. 2-9

Continuous Wave Lasers 12-119

OBIS Lasers OBIS 12-20

OBIS FP 21-27

OBIS Galaxy 28-31

OBIS LG 355 32-33

OBIS Laser Box 34-35

OBIS Accessories 36-41

OBIS Scientific Remote 42-43

BioRay Lasers BioRay 44-49

BioRay FR 50-53

Structured Light Flat Top Projector 54-57

CUBE Lasers CUBE 58-65

CUBE FP 66-73

Radius Lasers 74-75

ULN 76-77

Compass Lasers Compass 115M 78-79

Table of Contents

10 www.Coherent.com • [email protected] Reliability & Performance •

Page 13: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Continuous Wave Lasers

Sapphire Lasers Sapphire LP 80-83

Sapphire FP 84-87

Sapphire SF 88-89

Sapphire Driver Unit 90-91

Genesis Lasers Genesis CX STM-Series 92-99 Genesis CX 355 STM Compact (OEM) 100-103 Genesis MX STM-Series (OEM) 104-107 Genesis MX STM-Series 19-111 Genesis MX 607/639 STM (OEM) 112-113 Genesis MX 607/639 STM 114-117

Femtosecond Lasers 118-131

Chameleon Lasers Chameleon Discovery 118-121

Chameleon Ultra Family 122-123

Chameleon Vision 124-125

Chameleon Vision-S 126-127

Chameleon PreComp 128-129

Chameleon MPX 130-131

Laser Measurement and Control Accessories 132

Doing Business with Coherent 133

How to Contact Us 134

Visit the Coherent Website 135

Table of Contents

11Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 14: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBISLasers for Plug-and-Play Simplicity

Features

• Compact and identical foot print, dimensions, beam exit, interface, power supply and protocol

• Integrated control electronics

• OEM and end user versions

• Superior beam quality

• Analog and digital modulation

• USB with complete I/O and controls

• Superior reliability

• Compatible with MetaMorph and μManager Software

Mechanical Specifications

38 mm(1.5 in.)

StatusIndicator

SafetyShutter

Laser Exit ApertureM6 X 0.75 Thread

2.54 mm Deep

OEM Label

Fan

USB

SDR

Power

40 mm(1.57 in.)

19 mm(0.75 in.)

15.5 mm(0.61 in.)

70 mm(2.76 in.)

3 mm(0.12 in.)

64 mm(2.52 in.) 5 mm

(0.2 in.)

30 mm(1.18 in.)

4X Ø3.18 mm(0.13 in.) Thru

Top View

Front View

Rear View

Rear View with OEM Label Removed

12 www.Coherent.com • [email protected] Reliability & Performance •

Page 15: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications OBIS 375LX 405LX 413LX*Wavelength1(nm) 375 405 413OutputPower2(mW) 16 50 50,100,140 200 100SpatialMode TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.3 _<1.2 _<1.3 _<1.2BeamAsymmetry _<1:1.2 _<1:1.2 _<1:1.2BeamDiameterat1/e2(mm) 0.7±0.1 0.8±0.1 0.8±0.1BeamDivergence(mrad,full-angle) <1 <1 <1PointingStability(μrad) <30 <30 <30(over2hoursafterwarm-upand±3°C)PointingStabilityOverTemp.(μrad/°C) <5 <5 <5RMSNoise(%)(20Hzto20MHz) _<0.05 _<0.05 _<0.05Peak-to-PeakNoise(%)(20Hzto20kHz) <0.5 <0.5 <0.5Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5PolarizationRatio Minimum100:1,Vertical±5°LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 75 150 150 RiseTime(10%to90%)(nsec) <5 <2 <2 FallTime(90%to10%)(nsec) <5 <2 <2 ModulationDepth(extinctionratio) Infiniteat0Hz, Infiniteat0Hz, Infiniteat0Hz, >250:1at75MHz >250:1at150MHz >250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 500 500 500 RiseTime(10%to90%)(nsec) <700 <700 <700 FallTime(90%to10%)(nsec) <700 <700 <700 ModulationDepth(extinctionratio) >1,000,000:1 >1,000,000:1 >1,000,000:1StaticAlignmentTolerances BeamPositionfrom <1 <1 <1 Reference5(mm) BeamAngle5(mrad) <5 <5 <5 BeamWaistPositionatExitWindow(mm) n/a n/a n/aLaserSafetyClassification 3b 3b 3bESDProtection6 Level4 Level4 Level4PowerConsumption(W) Typical5, Typical5, Typical5, Max.13 Max.13 Max.13LaserHeadBaseplateTemp.(Max.,°C) 50 50 50HeatDissipationofLaserHead7(W) Typical5, Typical5, Typical5, Max.13 Max.13 Max.13AmbientTemperature8

OperatingCondition9(°C) 10to50 10to50 10to50 Non-operatingCondition(°C) -20to60 -20to60 -20to60ShockTolerance(g)(6ms) 30 30 30

OBIS Lasers for Plug-and-Play Simplicity

13Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

1 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power. ForLSversionsallresiduallaseremissionat808nmpumplightorfundamental<0.1mW.3 ForLXversionstheM2measuredwithModeMasterwith90/10cliplevels.4 ForLSversionstypicalpower-ondelay1minute.ForLXversionstypicalpower-ondelay0.1minutes.5 Seemechanicaldrawingforexitbeamlocation.6 Electro-StaticDischargeStandardIEC1000-4-2,1995.7 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.8 Non-Condensing.SeeUserManualformoredetail.9 ForLSversionslaserheadbaseplatetemperatureneedstobemaintainedat<_40°C.* Preliminaryversion.

Page 16: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS Lasers for Plug-and-Play Simplicity

14 www.Coherent.com • [email protected] Reliability & Performance •

System Specifications OBIS 422LX 445LXWavelength1(nm) 422 445OutputPower2(mW) 100 75SpatialMode TEM00 TEM00M2(BeamQuality)3 _<1.2 _<1.2BeamAsymmetry _<1:1.2 _<1:1.2BeamDiameterat1/e2(mm) 0.9±0.1 0.6±0.1BeamDivergence(mrad,full-angle) <1.1 <1.1PointingStability(μrad) <30 <30(over2hoursafterwarm-upand±3°C)PointingStabilityOverTemp.(μrad/°C) <5 <5RMSNoise(%)(20Hzto20MHz) __<0.05 _<0.05Peak-to-PeakNoise(%)(20Hzto20kHz) <0.5 <0.5Long-termPowerStability(%)(8hrs.,±3°C) <2 <2Warm-upTime4(minutes)(fromcoldstart) <5 <5PolarizationRatio Minimum100:1,Vertical±5°LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 150 150 RiseTime(10%to90%)(nsec) <2 <2 FallTime(90%to10%)(nsec) <2 <2 ModulationDepth(extinctionratio) Infiniteat0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 500 500 RiseTime(10%to90%)(nsec) <700 <700 FallTime(90%to10%)(nsec) <700 <700 ModulationDepth(extinctionratio) >1,000,000:1 >1,000,000:1StaticAlignmentTolerances BeamPositionfrom <1 <1 Reference5(mm) BeamAngle5(mrad) <5 <5 BeamWaistPositionatExitWindow(mm) n/a n/aLaserSafetyClassification 3b 3bESDProtection6 Level4 Level4PowerConsumption(W) Typical5, Typical5, Max.13 Max.13LaserHeadBaseplateTemp.(Max.,°C) 50 50HeatDissipationofLaserHead7(W) Typical5, Typical5, Max.13 Max.13AmbientTemperature8

OperatingCondition9(°C) 10to50 10to50 Non-operatingCondition(°C) -20to60 -20to60ShockTolerance(g)(6ms) 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power. ForLSversionsallresiduallaseremissionat808nmpumplightorfundamental<0.1mW.3 ForLXversionstheM2measuredwithModeMasterwith90/10cliplevels.4 ForLSversionstypicalpower-ondelay1minute.ForLXversionstypicalpower-ondelay0.1minutes.5 Seemechanicaldrawingforexitbeamlocation.6 Electro-StaticDischargeStandardIEC1000-4-2,1995.7 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.8 Non-Condensing.SeeUserManualformoredetail.9 ForLSversionslaserheadbaseplatetemperatureneedstobemaintainedat<_40°C.

Page 17: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS Lasers for Plug-and-Play Simplicity

15Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

System Specifications OBIS 458LX 473LX 488LX 488LSWavelength1(nm) 458 473 488 488OutputPower2(mW) 75 75 50 150 20,60,80,100,150SpatialMode TEM00 TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.2 _<1.2 _<1.2 _<1.1BeamAsymmetry _<1:1.2 _<1:1.2 __<1:1.2 _<1:1.1BeamDiameterat1/e2(mm) 0.8±0.1 0.8±0.1 0.8±0.1 0.7±0.1 0.7±0.05BeamDivergence(mrad,full-angle) <1.1 <1.1 <1.2 <1.2PointingStability(μrad) <30 <30 <30 <30(over2hoursafterwarm-upand±3°C)PointingStabilityOverTemp.(μrad/°C) <5 <5 <5 <5RMSNoise(%)(20Hzto20MHz) _<0.05 _<0.05 _<0.05 _<0.25Peak-to-PeakNoise(%)(20Hzto20kHz) <0.5 <0.5 <0.5 <1Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2 <2Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5 <5PolarizationRatio Minimum100:1,Vertical±5°LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 150 150 150 0.05 RiseTime(10%to90%)(nsec) <2 <2 <2 <18,000 FallTime(90%to10%)(nsec) <2 <2 <2.5 <2000 ModulationDepth(extinctionratio) Infiniteat0Hz,>250:1at150MHz Infiniteat 0Hzto50kHzAnalogModulation MaximumBandwidth(kHz) 500 500 500 100 RiseTime(10%to90%)(nsec) <700 <700 <700 <3000 FallTime(90%to10%)(nsec) <700 <700 <700 <3000 ModulationDepth(extinctionratio) >1,000,000:1 >1,000,000:1 >1,000,000:1 >50:1StaticAlignmentTolerances BeamPositionfromReference5(mm) <1 <1 <1 <0.5 BeamAngle5(mrad) <5 <5 <5 <2.5 BeamWaistPositionatExitWindow(mm) n/a n/a n/a ±200LaserSafetyClassification 3b 3b 3b 3bESDProtection6 Level4 Level4 Level4 Level4PowerConsumption(W) Typical5, Typical5, Typical5, Typical8, Max.13 Max.13 Max.13 Max.12LaserHeadBaseplateTemp.(Max.,°C) 50 50 50 40HeatDissipationofLaserHead7(W) Typical5, Typical5, Typical5, Typical8, Max.13 Max.13 Max.13 Max.12AmbientTemperature8 OperatingCondition9(°C) 10to50 10to50 10to50 15to40 Non-OperatingCondition(°C) -20to60 -20to60 -20to60 -20to60ShockTolerance(g)(6ms) 30 30 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power. ForLSversionsallresiduallaseremissionat808nmpumplightorfundamental<0.1mW.3 ForLXversionstheM2measuredwithModeMasterwith90/10cliplevels.4 ForLSversionstypicalpower-ondelay1minute.ForLXversionstypicalpower-ondelay0.1minutes.5 Seemechanicaldrawingforexitbeamlocation.6 Electro-StaticDischargeStandardIEC1000-4-2,1995.7 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.8 Non-Condensing.SeeUserManualformoredetail.9 ForLSversionslaserheadbaseplatetemperatureneedstobemaintainedat<_40°C.

Page 18: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications OBIS 505LX 514LS 514LX 520LXWavelength1(nm) 505 514 514 520OutputPower2(mW) 50 20 40 40SpatialMode TEM00 TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.2 _<1.1 _<1.2 _<1.2BeamAsymmetry _<1:1.2 _<1:1.1 _<1:1.2 _<1:1.2BeamDiameterat1/e2(mm) 0.7±0.1 0.7±0.05 0.6±0.1 0.6±0.1BeamDivergence(mrad,full-angle) <1.2 <1.2 <1.1 <1.1PointingStability(μrad) <30 <30 <30 <30(over2hoursafterwarm-upand±3°C) PointingStabilityOverTemp.(μrad/°C) <5 <5 <5 <5RMSNoise(%)(20Hzto20MHz) _<0.05 _<0.25 _<0.05 _<0.05Peak-to-PeakNoise(%)(20Hzto20kHz) <0.5 <1 <1 <1Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2 <2Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5 <5PolarizationRatio Minimum100:1,Vertical±5°LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 150 0.05 100 100 RiseTime(10%to90%)(nsec) <2 <18,000 <3.5 <3.5 FallTime(90%to10%)(nsec) <2.5 <2000 <2 <2 ModulationDepth(extinctionratio) Infiniteat Infinite Infiniteat Infiniteat 0Hz,>250:1 at0Hz 0Hz,>250:1 0Hz,>250:1 at150MHz to50kHz at100MHz at100MHzAnalogModulation MaximumBandwidth(kHz) 500 100 500 500 RiseTime(10%to90%)(nsec) <700 <3000 <700 <700 FallTime(90%to10%)(nsec) <700 <3000 <700 <700 ModulationDepth(extinctionratio) >1,000,000:1 >50:1 >1,000,000:1 >1,000,000:1StaticAlignmentTolerances BeamPositionfromReference5(mm) <1 <0.5 <1 <1 BeamAngle5(mrad) <5 <2.5 <5 <5 BeamWaistPositionatExitWindow(mm) n/a ±200 n/a n/aLaserSafetyClassification 3b 3b 3b 3bESDProtection6 Level4 Level4 Level4 Level4PowerConsumption(W) Typical5, Typical8, Typical5, Typical5, Max.13 Max.12 Max.13 Max.13LaserHeadBaseplateTemp.(Max.,°C) 50 40 50 50HeatDissipationofLaserHead7(W) Typical5, Typical8, Typical5, Typical5, Max.13 Max.12 Max.13 Max.13AmbientTemperature8 OperatingCondition9(°C) 10to50 15to40 10to50 10to50 Non-OperatingCondition(°C) -20to60 -20to60 -20to60 -20to60ShockTolerance(g)(6ms) 30 30 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power. ForLSversionsallresiduallaseremissionat808nmpumplightorfundamental<0.1mW.3 ForLXversionstheM2measuredwithModeMasterwith90/10cliplevels.4 ForLSversionstypicalpower-ondelay1minute.ForLXversionstypicalpower-ondelay0.1minutes.5 Seemechanicaldrawingforexitbeamlocation.6 Electro-StaticDischargeStandardIEC1000-4-2,1995.7 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.8 Non-Condensing.SeeUserManualformoredetail.9 ForLSversionslaserheadbaseplatetemperatureneedstobemaintainedat<_40°C.

OBIS Lasers for Plug-and-Play Simplicity

16 www.Coherent.com • [email protected] Reliability & Performance •

Page 19: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications OBIS 532LS 552LS 561LS 594LSWavelength1(nm) 532 552 561 594OutputPower2(mW) 20,50,80,100,150 20,60,80,100,150 20,50,80,100,150 20,60SpatialMode TEM00 TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.1 _<1.1 _<1.1 _<1.1BeamAsymmetry _<1:1.1 _<1:1.1 _<1:1.1 _<1:1.1BeamDiameterat1/e2(mm) 0.7±0.05 0.7±0.05 0.7±0.05 0.7±0.05BeamDivergence(mrad,full-angle) <1.2 <1.2 <1.2 <1.3PointingStability(μrad) <30 <30 <30 <30(over2hoursafterwarm-upand±3°C)PointingStabilityOverTemp.(μrad/°C) <5 <5 <5 <5RMSNoise(%)(20Hzto20MHz) _<0.25 _<0.25 _<0.25 _<0.25Peak-to-PeakNoise(%)(20Hzto20kHz) <1 <1 <1 <1Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2 <2Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5 <5PolarizationRatio Minimum100:1,Vertical±5°LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 0.05 0.05 0.05 0.05 RiseTime(10%to90%)(nsec) <18,000 <18,000 <18,000 <18,000 FallTime(90%to10%)(nsec) <2000 <2000 <2000 <2000 ModulationDepth(extinctionratio) Infiniteat0Hzto50kHzAnalogModulation MaximumBandwidth(kHz) 100 100 100 100 RiseTime(10%to90%)(nsec) <3000 <3000 <3000 <3000 FallTime(90%to10%)(nsec) <3000 <3000 <3000 <3000 ModulationDepth(extinctionratio) >50:1 >50:1 >50:1 >50:1StaticAlignmentTolerances BeamPositionfromReference5(mm) <0.5 <0.5 <0.5 <0.5 BeamAngle5(mrad) <2.5 <2.5 <2.5 <2.5 BeamWaistPositionatExitWindow(mm)±200 ±200 ±200 ±200LaserSafetyClassification 3b 3b 3b 3bESDProtection6 Level4 Level4 Level4 Level4PowerConsumption(W) Typical8, Typical8, Typical8, Typical8, Max.12 Max.12 Max.12 Max.12LaserHeadBaseplateTemp.(Max.,°C) 40 40 40 40HeatDissipationofLaserHead7(W) Typical8, Typical8, Typical8, Typical8, Max.12 Max.12 Max.12 Max.12AmbientTemperature8 OperatingCondition9(°C) 15to40 15to40 15to40 15to40 Non-OperatingCondition(°C) -20to60 -20to60 -20to60 -20to60ShockTolerance(g)(6ms) 30 30 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power. ForLSversionsallresiduallaseremissionat808nmpumplightorfundamental<0.1mW.3 ForLXversionstheM2measuredwithModeMasterwith90/10cliplevels.4 ForLSversionstypicalpower-ondelay1minute.ForLXversionstypicalpower-ondelay0.1minutes.5 Seemechanicaldrawingforexitbeamlocation.6 Electro-StaticDischargeStandardIEC1000-4-2,1995.7 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.8 Non-Condensing.SeeUserManualformoredetail.9 ForLSversionslaserheadbaseplatetemperatureneedstobemaintainedat<_40°C.

OBIS Lasers for Plug-and-Play Simplicity

17Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 20: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications OBIS 637LX 640LX 647LX 660LXWavelength1(nm) 637 640 647 660OutputPower2(mW) 140 40,100 120 100SpatialMode TEM00 TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.2 _<1.2 _<1.2 _<1.2BeamAsymmetry _<1:1.2 _<1:1.2 _<1:1.2 _<1:1.2BeamDiameterat1/e2(mm) 0.7±0.1 0.8±0.1 0.8±0.1 0.9±0.1BeamDivergence(mrad,full-angle) <1.3 <1.3 <1.3 <1.3PointingStability(μrad) <30 <30 <30 <30(over2hoursafterwarm-upand±3°C) PointingStabilityOverTemp.(μrad/°C) <5 <5 <5 <5RMSNoise(%)(20Hzto20MHz) _<0.05 _<0.05 _<0.05 _<0.05Peak-to-PeakNoise(%)(20Hzto20kHz) <0.5 <0.5 <0.5 <0.5Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2 <2Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5 <5PolarizationRatio Minimum100:1,Vertical±5°LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 150 150 150 150 RiseTime(10%to90%)(nsec) <2 <2 <2 <2 FallTime(90%to10%)(nsec) <2 <2 <2 <2 ModulationDepth(extinctionratio) Infiniteat0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 300 500 500 500 RiseTime(10%to90%)(nsec) <1200 <700 <700 <700 FallTime(90%to10%)(nsec) <800 <700 <700 <700 ModulationDepth(extinctionratio) >1,000,000:1 >1,000,000:1 >1,000,000:1 >1,000,000:1StaticAlignmentTolerances BeamPositionfromReference5(mm) <1 <1 <1 <1 BeamAngle5(mrad) <5 <5 <5 <5 BeamWaistPositionatExitWindow(mm) n/a n/a n/a n/aLaserSafetyClassification 3b 3b 3b 3bESDProtection6 Level4 Level4 Level4 Level4PowerConsumption(W) Typical5, Typical5, Typical5, Typical5, Max.13 Max.13 Max.13 Max.13LaserHeadBaseplateTemp.(Max.,°C) 50 50 50 50HeatDissipationofLaserHead7(W) Typical5, Typical5, Typical5, Typical5, Max.13 Max.13 Max.13 Max.13AmbientTemperature8 OperatingCondition9(°C) 10to50 10to50 10to50 10to50 Non-OperatingCondition(°C) -20to60 -20to60 -20to60 -20to60ShockTolerance(g)(6ms) 30 30 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power. ForLSversionsallresiduallaseremissionat808nmpumplightorfundamental<0.1mW.3 ForLXversionstheM2measuredwithModeMasterwith90/10cliplevels.4 ForLSversionstypicalpower-ondelay1minute.ForLXversionstypicalpower-ondelay0.1minutes.5 Seemechanicaldrawingforexitbeamlocation.6 Electro-StaticDischargeStandardIEC1000-4-2,1995.7 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.8 Non-Condensing.SeeUserManualformoredetail.9 ForLSversionslaserheadbaseplatetemperatureneedstobemaintainedat<_40°C.

OBIS Lasers for Plug-and-Play Simplicity

18 www.Coherent.com • [email protected] Reliability & Performance •

Page 21: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications OBIS 685LX 730LX 785LXWavelength1(nm) 685 730 785OutputPower2(mW) 40 30 50SpatialMode TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.2 _<1.2 _<1.2BeamAsymmetry _<1:1.2 _<1:1.2 _<1:1.2BeamDiameterat1/e2(mm) 0.8±0.1 0.8±0.1 0.7±0.1BeamDivergence(mrad,full-angle) <1.3 <1.3 <1.7PointingStability(μrad) <30 <30 <30(over2hoursafterwarm-upand±3°C) PointingStabilityOverTemp.(μrad/°C) <5 <5 <5RMSNoise(%)(20Hzto20MHz) _<0.05 _<0.05 _<0.05Peak-to-PeakNoise(%)(20Hzto20kHz) <0.5 <0.5 <0.5Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5PolarizationRatio Minimum100:1, Minimum100:1, Minimum25:1, Vertical±5° Vertical±5° Vertical±15°LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 150 150 100 RiseTime(10%to90%)(nsec) <2 <2 <4 FallTime(90%to10%)(nsec) <2 <2 <4 ModulationDepth(extinctionratio) Infiniteat0Hz, Infiniteat0Hz, Infiniteat0Hz, >250:1at150MHz >250:1at150MHz >250:1at100MHzAnalogModulation MaximumBandwidth(kHz) 500 500 450 RiseTime(10%to90%)(nsec) <700 <700 <800 FallTime(90%to10%)(nsec) <700 <700 <800 ModulationDepth(extinctionratio) >1,000,000:1 >1,000,000:1 >700,000:1StaticAlignmentTolerances BeamPositionfromReference5(mm) <1 <1 <1 BeamAngle5(mrad) <5 <5 <5 BeamWaistPositionatExitWindow(mm) n/a n/a n/aLaserSafetyClassification 3b 3b 3bESDProtection6 Level4 Level4 Level4PowerConsumption(W) Typical5, Typical5, Typical5, Max.13 Max.13 Max.13LaserHeadBaseplateTemp.(Max.,°C) 50 50 50HeatDissipationofLaserHead7(W) Typical5, Typical5, Typical5, Max.13 Max.13 Max.13AmbientTemperature8 OperatingCondition9(°C) 10to50 10to50 10to50 Non-OperatingCondition(°C) -20to60 -20to60 -20to60ShockTolerance(g)(6ms) 30 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power. ForLSversionsallresiduallaseremissionat808nmpumplightorfundamental<0.1mW.3 ForLXversionstheM2measuredwithModeMasterwith90/10cliplevels.4 ForLSversionstypicalpower-ondelay1minute.ForLXversionstypicalpower-ondelay0.1minutes.5 Seemechanicaldrawingforexitbeamlocation.6 Electro-StaticDischargeStandardIEC1000-4-2,1995.7 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.8 Non-Condensing.SeeUserManualformoredetail.9 ForLSversionslaserheadbaseplatetemperatureneedstobemaintainedat<_40°C.

OBIS Lasers for Plug-and-Play Simplicity

19Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 22: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

20 www.Coherent.com • [email protected] Reliability & Performance •

OBIS Lasers for Plug-and-Play Simplicity

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all OBIS lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Utility and Environmental Requirements

OperatingVoltage1(VDC) 12±2Dimensions(LxWxH) Laser 70x40x38mm(2.75x1.57x1.5in.) OBISRemote(optional) 105x68x36mm(4.13x2.68x1.42in.) DCPowerSupply(optional) 105x42x33mm(4.13x1.65x1.3in.) Cable,LasertoOBISRemote(optional) 1m(3.28ft.)(3meterand0.3metersoldseparately)Weights Laser 0.16kg(0.35lbs.) OBISRemote(optional) 0.24kg(0.53lbs.) DCPowerSupply(optional) 0.36kg(0.79lbs.) Cable,LasertoOBISRemote(optional) 0.1kg(0.22lbs.)for1meter1 Ifusersupplied,theDCpowersupplyhastomeetthefollowingrequirements:power>20W;ripple<5%peak-to-peak;lineregulation<0.5%.

Page 23: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS FPFiber Pigtailed Lasers in a Plug-and-Play Platform

Features

• Compact and identical foot print, dimensions, SM/PM fiber with FC/APC, interface, power supply and protocol

• Integrated control electronics

• OEM and end user versions

• Superior beam quality from single mode polarization maintaining fiber

• Analog and digital modulation

• USB with complete I/O and controls

38.1 mm(1.5 in.)

40 mm(1.57 in.)

3 mm(0.12 in.)

64 mm(2.52 in.)

30 mm(1.18 in.)

5 mm(0.2 in.)

4X Ø3.2 mm Thru(0.13 in.)

1m (minimum)(39.4 in.)

5.1 mm(0.2 in.)

FC Connector Key

Polarization±2° Max.

Laser Exit Aperture

Polish DirectionAxis ±4° Max.

View of Fiber from Connector End

Angle Polished 8 ±0.5°

.20 mm ±0.10 mm

8.0°3 mm PVC Coated MonocoilSteel Tubing

FC Connector KeyType R - Narrow Key(2.0 mm +0.02/-0.03 mm Key Width)

8.0°

OEM Label

Mechanical SpecificationsOBIS FP LX

Side View

Top View

Front View

• Superior reliability

• FC/APC connector

• Compatible with MetaMorph and μManager Software

21Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 24: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS FP Fiber Pigtailed Lasers in a Plug-and-Play Platform

22 www.Coherent.com • [email protected] Reliability & Performance •

System Specifications OBIS FP 405LX 413LX* 445LXWavelength1(nm) 405 413 445OutputPower2(mW) 50,100 50 45OutputfromFiber FC/APC; FC/APC; FC/APC; 8°angled8 8°angled8 8°angled8

FiberCableType 3mmMono-Coil 3mmMono-Coil 3mmMono-CoilFiberCableLength(m)(minimum) 1 1 1FiberNumericalAperture(NA)(1/e2) 0.055 0.055 0.055FiberCoreDiameter(μm)(typical) 3.5 3.5 3.5SpatialMode TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.1 _<1.1 _<1.1BeamAsymmetry _<1:1.1 _<1:1.1 _<1:1.1RMSNoise(%)(20Hzto20MHz) _<0.2 _<0.2 _<0.2Peak-to-PeakNoise(%)(20Hzto20kHz) _<2 _<2 _<2Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2Long-termOutputPowerAverage(%/hrs.) _<5/1000 _<5/1000 _<5/1000Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5PolarizationRatio Minimum100:1 Minimum100:1 Minimum100:1LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 150 150 150 RiseTime(10%to90%)(nsec) <2 <2 <2 FallTime(90%to10%)(nsec) <2 <2 <2 ModulationDepth(extinctionratio) Infiniteat0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 500 500 500 RiseTime(10%to90%)(nsec) <700 <700 <700 FallTime(10%to90%)(nsec) <700 <700 <700 ModulationDepth(extinctionratio) >1,000,000:1 >1,000,000:1 >1,000,000:1LaserSafetyClassification 3b 3b 3bESDProtection5 Level4 Level4 Level4PowerConsumption(W) Typical5, Typical5, Typical5, Max.13 Max.13 Max.13LaserHeadBaseplateTemperature(Max.,°C) 40 40 40HeatDissipationofLaserHead6(W) Typical5, Typical5, Typical5, Max.13 Max.13 Max.13AmbientTemperature7 OperatingCondition(°C) 10to40 10to40 10to40 Non-OperatingCondition(°C) -20to+60 -20to+60 -20to+60ShockTolerance(g)(6ms) 30 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power.3 M2measuredwithModeMasterwith90/10cliplevels.4 Typicalpower-ondelay0.1minutes.5 Electro-StaticDischargeStandardIEC1000-4-2,1995.6 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.7 Non-Condensing.SeeUserManualformoredetail.8 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.* Preliminaryversion.

Page 25: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS FP Fiber Pigtailed Lasers in a Plug-and-Play Platform

23Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

System Specifications OBIS FP 473LX 488LX 488LSWavelength1(nm) 473 488 488OutputPower2(mW) 50 30,100 15 40,60,80,120OutputfromFiber FC/APC; FC/APC; FC/APC; FC/APC; 8°angled8 8°angled8 8°angled 8°angled8

FiberCableType 3mm 3mm 5mm Mono-Coil Mono-Coil ProtectiveTubingFiberCableLength(m)(minimum) 1 1 1FiberNumericalAperture(NA)(1/e2) 0.055 0.055 0.1 0.06FiberCoreDiameter(μm)(typical) 3.5 3.5 4SpatialMode TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.1 _<1.1 _<1.1BeamAsymmetry _<1:1.1 _<1:1.1 _<1:1.1RMSNoise(%)(20Hzto20MHz) _<0.2 _<0.2 _<0.25Peak-to-PeakNoise(%)(20Hzto20kHz) _<2 _<2 _<1Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2Long-termOutputPowerAverage(%/hrs.) _<4/1000 _<4/1000 -Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5PolarizationRatio Minimum100:1 Minimum100:1 Minimum100:1LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 150 150 0.05 RiseTime(10%to90%)(nsec) <2 <2 <18,000 FallTime(90%to10%)(nsec) <2 <2.5 <2000 ModulationDepth(extinctionratio) Infiniteat0Hz, Infiniteat0Hz, Infiniteat >250:1at150MHz >250:1at150MHz 0Hzto50kHzAnalogModulation MaximumBandwidth(kHz) 500 500 100 RiseTime(10%to90%)(nsec) <700 <700 <3000 FallTime(10%to90%)(nsec) <700 <700 <3000 ModulationDepth(extinctionratio) >1,000,000:1 >1,000,000:1 >50:1LaserSafetyClassification 3b 3b 3bESDProtection5 Level4 Level4 Level4PowerConsumption(W) Typical5, Typical5, Typical8, Max.13 Max.13 Max.12LaserHeadBaseplateTemperature(Max.,°C) 40 40 40HeatDissipationofLaserHead6(W) Typical5, Typical5, Typical8, Max.13 Max.13 Max.12AmbientTemperature7 OperatingCondition(°C) 10to40 10to40 15to40 Non-OperatingCondition(°C) -20to+60 -20to+60 -20to+60ShockTolerance(g)(6ms) 30 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power.3 M2measuredwithModeMasterwith90/10cliplevels.4 Typicalpower-ondelay0.1minutes.5 Electro-StaticDischargeStandardIEC1000-4-2,1995.6 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.7 Non-Condensing.SeeUserManualformoredetail.8 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.

Page 26: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS FP Fiber Pigtailed Lasers in a Plug-and-Play Platform

24 www.Coherent.com • [email protected] Reliability & Performance •

System Specifications OBIS FP 505LX 514LS 514LX 520LXWavelength1(nm) 505 514 514 520OutputPower2(mW) 50 15 30 25OutputfromFiber FC/APC; FC/APC; FC/APC; FC/APC; 8°angled8 8°angled 8°angled8 8°angled8

FiberCableType 3mm 5mm 3mm 3mm Mono-Coil ProtectiveTubing Mono-Coil Mono-CoilFiberCableLength(m)(minimum) 1 1 1 1FiberNumericalAperture(NA)(1/e2) 0.055 0.1 0.055 0.055FiberCoreDiameter(μm)(typical) 3.5 4 4.5 4.5SpatialMode TEM00 TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.1 _<1.1 _<1.1 _<1.1BeamAsymmetry _<1:1.1 _<1:1.1 _<1:1.1 _<1:1.1RMSNoise(%)(20Hzto20MHz) _<0.2 <0.2 _<0.25 _<0.25Peak-to-PeakNoise(%)(20Hzto20kHz) _<2 _<1 _<2 _<2Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2 <2Long-termOutputPowerAverage(%/hrs.) _<4/1000 - _<3/1000 _<3/1000Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5 <5PolarizationRatio Minimum100:1 Minimum100:1 Minimum100:1 Minimum100:1LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 150 0.05 100 100 RiseTime(10%to90%)(nsec) <2 <18,000 <3.5 <3.5 FallTime(90%to10%)(nsec) <2 <2000 <2 <2 ModulationDepth(extinctionratio) Infiniteat0Hz, Infiniteat Infiniteat0Hz, Infiniteat0Hz, >250:1at150MHz 0Hzto50kHz >250:1at100MHz >250:1at100MHzAnalogModulation MaximumBandwidth(kHz) 500 100 500 500 RiseTime(10%to90%)(nsec) <700 <3000 <700 <700 FallTime(10%to90%)(nsec) <700 <3000 <700 <700 ModulationDepth(extinctionratio) >1,000,000:1 >50:1 >1,000,000:1 >1,000,000:1LaserSafetyClassification 3b 3b 3b 3bESDProtection5 Level4 Level4 Level4 Level4PowerConsumption(W) Typical5, Typical8, Typical5, Typical5, Max.13 Max.12 Max.13 Max.13LaserHeadBaseplateTemperature(Max.,°C) 40 40 40 40HeatDissipationofLaserHead6(W) Typical5, Typical8, Typical5, Typical5, Max.13 Max.12 Max.13 Max.13AmbientTemperature7 OperatingCondition(°C) 10to40 15to40 10to40 10to40 Non-OperatingCondition(°C) -20to+60 -20to+60 -20to+60 -20to+60ShockTolerance(g)(6ms) 30 30 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power.3 M2measuredwithModeMasterwith90/10cliplevels.4 Typicalpower-ondelay0.1minutes.5 Electro-StaticDischargeStandardIEC1000-4-2,1995.6 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.7 Non-Condensing.SeeUserManualformoredetail.8 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.

Page 27: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications OBIS FP 532LS 552LS 561LS 594LSWavelength1(nm) 532 552 561 594OutputPower2(mW) 20 40,60,80,120 15 40,60,80,120 40,60,80,120 40OutputfromFiber FC/APC; FC/APC; FC/APC; FC/APC; FC/APC; FC/APC; 8°angled 8°angled8 8°angled 8°angled8 8°angled8 8°angled8

FiberCableType 5mm 5mm 5mm 5mm ProtectiveTubing ProtectiveTubing ProtectiveTubing ProtectiveTubingFiberCableLength(m)(minimum) 1 1 1 1FiberNumericalAperture(NA)(1/e2) 0.1 0.06 0.1 0.06 0.06 0.06FiberCoreDiameter(μm)(typical) 4 4 4 4SpatialMode TEM00 TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.1 _<1.1 _<1.1 _<1.1BeamAsymmetry _<1:1.1 __<1:1.1 _<1:1.1 _<1:1.1RMSNoise(%)(20Hzto20MHz) <0.25 __<0.25 <0.25 <0.25Peak-to-PeakNoise(%)(20Hzto20kHz) _<1 _<1 _<1 _<1Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2 <2Long-termOutputPowerAverage(%/hrs.) - - - -Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5 <5PolarizationRatio Minimum100:1 Minimum100:1 Minimum100:1 Minimum100:1LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 0.05 0.05 0.05 0.05 RiseTime(10%to90%)(nsec) <18,000 <18,000 <18,000 <18,000 FallTime(90%to10%)(nsec) <2000 <2000 <2000 <2000 ModulationDepth(extinctionratio) Infiniteat0Hzto50kHzAnalogModulation MaximumBandwidth(kHz) 100 100 100 100 RiseTime(10%to90%)(nsec) <3000 <3000 <3000 <3000 FallTime(10%to90%)(nsec) <3000 <3000 <3000 <3000 ModulationDepth(extinctionratio) >50:1 >50:1 >50:1 >50:1LaserSafetyClassification 3b 3b 3b 3bESDProtection5 Level4 Level4 Level4 Level4PowerConsumption(W) Typical8, Typical8, Typical8, Typical8, Max.12 Max.12 Max.12 Max.12LaserHeadBaseplateTemperature(Max.,°C) 40 40 40 40HeatDissipationofLaserHead6(W) Typical8, Typical8, Typical8, Typical8, Max.12 Max.12 Max.12 Max.12AmbientTemperature7 OperatingCondition(°C) 15to40 15to40 15to40 15to40 Non-OperatingCondition(°C) -20to+60 -20to+60 -20to+60 -20to+60ShockTolerance(g)(6ms) 30 30 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power.3 M2measuredwithModeMasterwith90/10cliplevels.4 Typicalpower-ondelay0.1minutes.5 Electro-StaticDischargeStandardIEC1000-4-2,1995.6 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.7 Non-Condensing.SeeUserManualformoredetail.8 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.

OBIS FP Fiber Pigtailed Lasers in a Plug-and-Play Platform

25Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 28: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications OBIS FP 637LX 640LX 647LX 660LXWavelength1(nm) 637 640 647 660OutputPower2(mW) 100 75 100 75OutputfromFiber FC/APC; FC/APC; FC/APC; FC/APC; 8°angled 8°angled 8°angled 8°angledFiberCableType 3mm 3mm 3mm 3mm Mono-Coil Mono-Coil Mono-Coil Mono-CoilFiberCableLength(m)(minimum) 1 1 1 1FiberNumericalAperture(NA)(1/e2) 0.09 0.09 0.09 0.09FiberCoreDiameter(μm)(typical) 4.5 4.5 4.5 4.5SpatialMode TEM00 TEM00 TEM00 TEM00M2(BeamQuality)3 _<1.1 _<1.1 _<1.1 _<1.1BeamAsymmetry _<1:1.1 _<1:1.1 _<1:1.1 _<1:1.1RMSNoise(%)(20Hzto20MHz) _<0.2 _<0.2 _<0.2 _<0.2Peak-to-PeakNoise(%)(20Hzto20kHz) _<2 _<2 _<2 _<2Long-termPowerStability(%)(8hrs.,±3°C) <2 <2 <2 <2Long-termOutputPowerAverage(%/hrs.) __<3/1000 _<3/1000 _<3/1000 _<3/1000Warm-upTime4(minutes)(fromcoldstart) <5 <5 <5 <5PolarizationRatio Minimum100:1 Minimum100:1 Minimum100:1 Minimum100:1LaserDriveModes CW,AnalogModulation,DigitalModulationandComputerControlDigitalModulation MaximumBandwidth(MHz) 150 150 150 150 RiseTime(10%to90%)(nsec) <2 <2 <2 <2 FallTime(90%to10%)(nsec) <2 <2 <2 <2 ModulationDepth(extinctionratio) Infiniteat0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 300 500 500 500 RiseTime(10%to90%)(nsec) <1200 <700 <700 <700 FallTime(10%to90%)(nsec) <800 <700 <700 <700 ModulationDepth(extinctionratio) >1,000,000:1 >1,000,000:1 >1,000,000:1 >1,000,000:1LaserSafetyClassification 3b 3b 3b 3bESDProtection5 Level4 Level4 Level4 Level4PowerConsumption(W) Typical5, Typical5, Typical5, Typical5, Max.13 Max.13 Max.13 Max.13LaserHeadBaseplateTemperature(Max.,°C) 40 40 40 40HeatDissipationofLaserHead6(W) Typical5, Typical5, Typical5, Typical5, Max.13 Max.13 Max.13 Max.13AmbientTemperature7

OperatingCondition(°C) 10to40 10to40 10to40 10to40 Non-OperatingCondition(°C) -20to+60 -20to+60 -20to+60 -20to+60ShockTolerance(g)(6ms) 30 30 30 301 Laser-to-laserwavelengthtolerance±2nmforallOBISLSversions.ForOBISLXwavelengthtoleranceof±5nmexceptfor413LX witha410nmto420nmrange,520LXwitha520nmto530nmrange,640LXwith635nmto644nmrange,660LXwith 652nmto665nmrangeand685LXwith675nmto695nmrange.2 OutputpowerisvariableinCWModefrom1mW(1%forLXModels)to110%ofratedpower.Specificationsarevalidfor100%power.3 M2measuredwithModeMasterwith90/10cliplevels.4 Typicalpower-ondelay0.1minutes.5 Electro-StaticDischargeStandardIEC1000-4-2,1995.6 Typically85%ofheatloadthroughthebaseplate.SeeUsersManualformoredetail.7 Non-Condensing.SeeUserManualformoredetail.

OBIS FP Fiber Pigtailed Lasers in a Plug-and-Play Platform

26 www.Coherent.com • [email protected] Reliability & Performance •

Page 29: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS FP Fiber Pigtailed Lasers in a Plug-and-Play Platform

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all OBIS FP lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Utility and Environmental Requirements

OperatingVoltage1(VDC) 12±2Dimensions(LxWxH) Laser 70x40x38mm(2.75x1.57x1.5in.) OBISRemote(optional) 105x68x36mm(4.13x2.68x1.42in.) DCPowerSupply(optional) 105x42x33mm(4.13x1.65x1.3in.) Cable,LasertoOBISRemote(optional) 1m(3.28ft.)(3meterand0.3metersoldseparately) FiberMinimumBendRadius 51mm(2.0in.)Weights Laser 0.23kg(0.5lbs.) OBISRemote(optional) 0.23kg(0.5lbs.) DCPowerSupply(optional) 0.36kg(0.79lbs.) Cable,LasertoOBISRemote(optional) 0.1kg(0.22lbs.)for1meter FiberTensileLoad(max.) 1kg(2.2lbs.)1 Ifusersupplied,theDCpowersupplyhastomeetthefollowingrequirements:power>20W;ripple<5%peak-to-peak;lineregulation<0.5%.

Mechanical SpecificationsOBIS FP LS

OEM Label

40 mm(1.57 in.)

4 mm(0.16 in.)

3 mm(0.12 in.)

64 mm (2.52 in.)

30 mm(1.18 in.)

4X Ø3.2 mm Thru(0.13 in.)

1.0m (minimum) (39.4 in.) 70 mm (2.76 in.)

5 mm(0.2 in.)

37.9 mm(1.49 in.)

5.1 mm(0.2 in.)

FC Connector Key

Laser Exit ApertureView of Fiber from Connector End

8° ±0.5°FC Connector KeyNarrow Key

Protective Tubing 5 mm (0.2 in.)Minimum Bend Radius 51 mm (2 in.)

Side View Rear View

Top View

FrontView

27Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 30: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS GalaxyFiber Input, Fiber Output, 8 Channel Beam Combiner

Features

• Compact and low profile

• Rugged design

• 8 inputs and 1 output fiber

• Choices of input wavelengths: 405 nm, 445 nm or 458 nm, 488 nm, 514 nm, 532 nm, 552 nm or 561 nm, 590 nm and 640 nm

• Single-mode polarization-maintaining

• High transmission beam combining at >_60% throughput per channel

• Plug-and-play FC inputs

• 2 meter steel jacketed output fiber

Mechanical Specifications

405 nm

OUTPUT

445/458 nm

488 nm

640 nm

590 nm

552/561 nm

532 nm

514 nm

225 mm (8.9 in.)

222.7 mm (8.8 in.)

50 mm(2.0 in.)

169.6 mm(6.7 in.)25.4 mm

(1.0 in.)

228.6 mm (9.0 in.)

29.1 mm (1.1 in.)

Interior View1

FC/APC

Top View

Side View

1 AllnineinternalconnectionsareFC/UFC.

28 www.Coherent.com • [email protected] Reliability & Performance •

Page 31: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS Galaxy Fiber Input, Fiber Output, 8 Channel Beam Combiner

System Specifications1 8InputFiberConnections2 405nm,445nmor458nm,488nm,514nm,532nm, 552nmor561nm,590nm,640nmPowerThroughputPerChannel3(%) >60MaximumPowerPerChannel(mW) 100MaximumTotalOutputPower(mW) <500RMSNoise(%)(20Hzto2MHz) <0.5Peak-to-PeakNoise(%)(20Hzto20kHz) <2PowerThroughputVariation(%)–SameFiberConnector,Connect/Disconnect ±5PowerThroughputVariation(%)–ExchangeFiberConnectors ±15FiberConnectorType4 FCform-factor,ultra-flatcontactFC/UFCwithextended-lifeinterfacePolarizationMaintainingFiber,PER Guarantee>50:1outputwitha100:1inputLong-TermPowerThroughput(%)(8hours,±3°C) >95Long-TermPowerThroughput(average)(%) <_2/1000hours

ConnectorType5(distalend) FC/APC,8°angled,withextended-lifeinterfaceFiberCableType 3mmmono-coilFiberCableLength(m)(minimum) 2FiberNumericalAperture(NA)(1/e2) 0.055FiberCoreDiameter(μm)(typical) 3.8SpatialMode TEM00M2(BeamQuality)6 <_1.1FiberMinimumBendRadius 51mm(2.0in.)FiberTensileLoad(maximum) 1kg(2.2lbs.)ConnectorType4(toOBISGalaxy) FCform-factor,ultra-flatcontactFC/UFCwithextended-lifeinterface

Dimensions 229x170x29mm(9.0x6.7x1.1in.)Weight 1.4kg(3lbs.)ShockTolerance7(g)(11ms) 30Vibration7(g-RMS)(20to2kHz) 7.7AmbientTemperature8

OperatingTemperature 10°Cto50°CStorageTemperature -20°Cto60°CLaserSafetyClassification9 NotApplicable

OutputFiber(FC/UFCtoFC/APC) Part#1254255

BeamCombiner,8InputFC/UFC,SingleOutputFC/APC,405,445,488,514,532,552,590,640 Part#1253553BeamCombiner,8InputFC/UFC,SingleOutputFC/APC,405,458,488,514,532,552,590,640 Part#1253554BeamCombiner,8InputFC/UFC,SingleOutputFC/APC,405,445,488,514,532,561,590,640 Part#1253555BeamCombiner,8InputFC/UFC,SingleOutputFC/APC,405,458,488,514,532,561,590,640 Part#12535561 Systemspecificationsmeasuredat25°C.2 Allinputchannelsrequirea±1nmcenterwavelengthtolerance.3 Powerthroughputperchanneldoesnotincludetheconnectorrepeatabilitytolerance.4 Proprietaryinterface.Purchaseoutputfiberforapplicationsthatrequirefusionsplicing.5 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.6 M2measuredwithModeMasterwith90/10ClipLevels.7 Non-Operationalwithabefore/afterchangeof<10%.8 Non-Condensing.Nothermeticallysealed.9 OBISGalaxyisnotalaserandthereforetheLaserSafetyClassificationisdeterminedbytheend-userandapplication. RefertoCDRH21CFR1040subchapterJorIEC60825-1.10TheOutputFibermaybeusedinreverseasaninputchanneltoair-launchalaserintotheFC/APCconnector.

Utility and Environmental Requirements

Output Fiber10

Accessories

Part Numbers

29Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 32: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS Galaxy Fiber Input, Fiber Output, 8 Channel Beam Combiner

Lasers for OBIS GalaxyAlllaserssameasstandardproductexceptFCconnectorchangedtoUFCtype.

OBIS FP LX Lasers for OBIS Galaxy Part NumberOBIS405nmLX50mWLaser:FiberPigtail:UFC,Galaxy 1236438OBIS405nmLX100mWLaser:FiberPigtail:UFC,Galaxy 1236439OBIS445nmLX45mWLaser:FiberPigtail:UFC,Galaxy 1236441OBIS458nmLX45mWLaser:FiberPigtail:UFC,Galaxy 1236442OBIS488nmLX30mWLaser:FiberPigtail:UFC,Galaxy 1236443OBIS488nmLX100mWLaser:FiberPigtail:UFC,Galaxy 1236444OBIS514nmLX30mWLaser:FiberPigtail:UFC,Galaxy 1253198OBIS640nmLX75mWLaser:FiberPigtail:UFC,Galaxy 1236445OBIS FP LS Lasers for OBIS Galaxy Part NumberOBIS532nmLS80mWLaser:FiberPigtail:UFC,Galaxy 1276599OBIS552nmLS80mWLaser:FiberPigtail:UFC,Galaxy 1275619OBIS561nmLS80mWLaser:FiberPigtail:UFC,Galaxy 1275608Sapphire FP Lasers for OBIS Galaxy Part NumberSapphire514-FPUFCOEMLaserSystem,120mW,Galaxy 1276125Sapphire532-FPUFCOEMLaserSystem,120mW,Galaxy 1276167Sapphire552-FPUFCOEMLaserSystem,120mW,Galaxy 1276186Sapphire561-FPUFCOEMLaserSystem,120mW,Galaxy 1276187Sapphire588-FPUFCOEMLaserSystem,40mW,Galaxy 1276188

30 www.Coherent.com • [email protected] Reliability & Performance •

OBIS FP LX Laser OBIS FP LS Laser Sapphire FP Laser

VISIBLE AND INVISIBLE LASER RADIATION.AVOID EYE OR SKIN EXPOSURE TO

DIRECT OR SCATTERED RADIATION.CLASS II Ib LASER PRODUCT.

350 nm to 1100 nm<500 mW

VISIBLE AND INVISIBLE LASER RADIATION.AVOID EYE OR SKIN EXPOSURE TO

DIRECT OR SCATTERED RADIATION.CLASS IV LASER PRODUCT.

400 nm to 700 nm<10W

Page 33: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS Galaxy Fiber Input, Fiber Output, 8 Channel Beam Combiner

FC Connector Key

Polarization±2° Max.

Laser Aperture

Polish DirectionNot Applicable to

FC/UFC Connector

View of Fiber from Connector End

3 mm PVC Coated Monocoil

Tubing

FC Connector KeyType R - Narrow Key

(2.0 mm +0.02/-0.03 mm Key Width)

2m (minimum)(78.7 in.)

FC Connector Key

Polarization±2° Max.

Laser Aperture

Polish DirectionAxis ±4° Maximum

View of Fiber from Connector End

3 mm PVC Coated MonocoilTubing

FC Connector KeyType R - Narrow Key(2.0 mm +0.02/-0.03 mm Key Width)

8.0°

Side View

Mechanical Specificationsfor the Output Fiber (one included)

FC/APC Distal End - Output

FC/UFC Launch End - Input

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all OBIS Galaxy Beam Combiners. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

31Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 34: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS LG 355-20Compact True CW 355 Laser

Mechanical Specifications

55.8 mm(2.2 in.)

25.9 mm(1.02 in.)

36.3 mm(1.43 in.)

70.0 mm(2.76 in.)

55.0 mm(2.17 in.)

115.0 mm(4.53 in.)

125.0 mm(4.92 in.)

EmissionIndicator

Output Beam

Shutter Control

Mounting Holesfor 3 mm or No. 4 Screws(4X)

USB Control Fan

StatusIndicators

Heat Sink Surface

Laser Head

Top View

Side ViewRear View

Bottom View Front View

Features

• Superior mode quality

• Variable power setting

• New reduced size

• OPSL reliability

• Integrated control electronics

• USB and serial for complete I/O and controls

• Coherent connection digital interfacing protocol

• Multiple mounting options

32 www.Coherent.com • [email protected] Reliability & Performance •

Page 35: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications OBIS LG355-20(OEM)Wavelength(nm) 355±2FWHMLinewidth(GHz) <50PulseFormat CWSpectralPurity(%) >99OutputPower(mW) >20SpatialMode TEM00BeamQuality(M2) <1.2BeamCircularity2 1.0±0.15BeamWaistDiameter(mm)(FW,1/e2) 1.0±0.2BeamDivergence(mrad)(FW,1/e2) <1.2BeamWaistLocation3(mm) ±325BeamPointingStability(μrad/°C) <10PolarizationRatio Linear,>100:1PolarizationDirection Vertical,±5°Noise(%,RMS)(10Hzto1MHz) <0.25PowerStability(%)(pk-pk) ±<1Warm-UpTime(minutes) <10CDRHCompliant4 No

OperatingVoltage(VDC) 24±10%PowerConsumption(W) <130

AmbientTemperature Operating 10to40°C(50to104°F) Non-Operating -10to60°C(-14to160°F)RelativeHumidity5(%) 5to95CEMarking EN61010/EN60825/EN61326 EN55011/EN5058Dimensions(LxWxH) LaserHead6 125.0x70.0x36.2mm(4.9x2.76x1.43in.) PowerSupply7

Cables(laserheadtopowersupply7) 2m(6.5ft.)1 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.2 Circularitydefinedasverticaldiameterdividedbyhorizontaldiameter.3 Negativevaluecorrespondstoalocationinsidethelaserhead.4 Readytobeintegratedincompliantsystem.5 Non-condensing.6 Backconnectornotincludedinlaserheadlengthdimension.7 Powersupplynotincluded.

OBIS LG 355-20 Compact True CW 355 Laser

Electrical Specifications

Environmental Conditions

33Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all OBIS LG 355-20. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Page 36: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

76.2 mm(3.0 in.)

50 mm(2.0 in.)

Ø7.0 (3) Thru (8X)

279.4 mm (11.0 in.)

275 mm (10.8 in.)5 Bays forOBIS Lasers

184.2 mm(7.3 in.)

Air Intakewith Cleanable

Air Filters4-40 Tapped Holes (2X)3.6 mm (0.14 in.) Deep Both Sides

85.7 mm(3.4 in.)

14.2 mm(0.6 in.)

62.3 mm(2.5 in.)

Laser Interlock

PowerUSB CommunicationsMini-B

Ø11.4 mm (0,5 in.)Fiber/Free SpaceBeam Exit Holes (5X)

Air Exhaust, 3X<509 L/min. (18 CFM) Total

RemovableMountingBrackets (2X)

Key Switch Analog/DigitalModulation Inputand Status LEDfor Each Laser

Holes for MountingOBIS Galaxy Unit 4X #4 CountersinkClearance Hole fromOpposite Side Included Hole CoverPlugs Not Shown

System Status LEDPower Button

RS-232Communications

241.3 mm(9.5 in.)

86.2 mm(3.4 in.)

0 m

m(0

in.)

0 m

m(0

in.)

0 mm (0 in.)

84.6 mm (3.3 in.)96.6 mm (3.8 in.)

123.1 mm (4.8 in.)135.8 mm (5.3 in.)

28.0

mm

(1.1

in.)

204.

2 m

m(8

.0 in

.)20

8.6

mm

(8.2

in.)

27.2

mm

(1.1

in.)

71.6

mm

(2.8

in.)

116.

1 m

m(4

.6 in

.)16

0.5

mm

(6.3

in.)

205.

0 m

m(8

.1 in

.)

87.8 mm(3.5 in.)

to RubberFeet

OBIS Laser BoxLaser Mount and I/O for 5 OBIS Lasers

Features

• Integrated 5 bay mount for OBIS lasers

• Heat sinks and cooling fans

• Modulation inputs for analog and digital for five lasers

• USB and RS-232 interface for additional control from host computer

• Coherent Connection software for PC

• Status indicators for each laser

• External power supply

• Laser safety features such as key switch, interlock

Mechanical SpecificationsTop View

Front View

Rear View

Side View(Mounting Bracket Shown Removed)

With Top Cover Removed

34 www.Coherent.com • [email protected] Reliability & Performance •

Page 37: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS Laser Box Laser Mount and I/O for 5 OBIS Lasers

189 mm(7.4 in.)

IEC-320-C14Input Receptacle

89.4 mm(3.5 in.)

Cord Length:1219.2 mm

(48 in.)

47.1 mm(1.9 in.)

System Specifications OBISLaserBox LaserBox–5bay1 Part#1228877 PowerSupply2 IncludedHostComputerRemoteControlviaUSB3 USB2.0,MiniBHostComputerRemoteControlviaRS-2323 RS-232,115.2K,8N1,DB-9FAnalogInputs,5each SMBConnector,0Vto5V,50OhminputimpedanceDigitalInputs4, 5each SMBConnector,0Vto3V,50OhminputimpedanceInterlock Yes,includedwithshortingwireLaserStatusIndicators Yes,IndividualLEDforeachLaserWarm-upTime(minutes)(fromcoldstart) <2CoherentConnectionSoftwareforPC IncludedonUSBdrivewithusermanualSafety Keyswitchandinterlock

PowerConsumption(W)(typical)withnolasers 5PowerConsumption(W)(maximum) 140InternalCoolingFan Yes,3eachPowerInputtoLaserBox,6Pin(VDC) 10to14at10AmaximumMolexP/N43025-0600 formatingconnectorPowerCord(USA) 2.4m(8ft.)OperatingCondition5(°C) 10to40Non-OperatingCondition5(°C) -10to60ShockTolerance(g)(6ms) 20OperatingVoltage(VAC) 90to264,47to63HzDimensions(LxWxH) 241x184x88mm(9.5x7.3x3.5in.)Weight 3.9kg(8.5lbs.)1 Laserssoldseparately.2 Powersupplyincluded.Orderitemnumber1211389forspareorreplacement.3 Hostcomputernotprovided.RS-232andUSBcablenotprovided.4 DigitalModulationcanbedrivenupto5Volts.5 Non-condensing.

Utility and Environmental Requirements

Example of Laser Box with Cover Removed

OBIS 6-Laser Remote Power SupplyPart#1211389included

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all OBIS Laser Boxes. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

35Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 38: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS AccessoriesOBIS Remotes, Heat Sink, Power Supply and Accessories

Features

• OBIS Remote offers: - laser safety features (CDRH) such as key switch and interlock - laser status indicators - full input and output connections for control, analog modulation and digital modulation - compact power supply for single laser - brackets for mounting and stacking included

• OBIS 6-Laser Remote offers: - laser safety features (CDRH) such as key switch and interlock - six power cables to provide power to the OBIS lasers - single power supply with 6 laser capacity - individual on/off switches - brackets for mounting and stacking included

• Optional heat sink, power supply and cables

OBIS Remote for Single LaserPart#1173961

104.9 mm(4.1 in.)

67.5 mm(2.7 in.)

9.2 mm(0.4 in.)2 Places

13.7 mm(0.5 in.)2 Places12 mm

(0.5 in.)2 Places

43.5 mm(1.7 in.)2 Places

32 mm(1.3 in.)

35.9 mm(1.4 in.)

4X #4-40 Threads2 Places, Near and Far Side

Top View

Side View

Rear View

Front View

36 www.Coherent.com • [email protected] Reliability & Performance •

Page 39: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

12 mm(0.47 in.)

50 m

m (1

.97

in.)

50 mm (1.97 in.) 165.2 mm (6.5 in.)

4x M3 6 mm (0.24 in.)

0 m

m(0

.0 in

.)3.

5 m

m(0

.14

in.)

8.5

mm

(0.3

3 in

.)23

.5 m

m(0

.93

in.)

87.5

mm

(3.4

4 in

.)

30 m

m(1

.18

in.)

25.4

mm

(1.0

in.)

25 m

m(0

.98

in.)

20.5

mm

(0.8

in.)

100.8 mm (3.97 in.)

3x OBISAlignment Pins

Connector 2 PosVendor: MolexVendor Part: 51021-0200

Fan

0.0 OBISDatum Point

Threads for Accessory Mounting

2x M4 8

2 x 8-32 8.33 mm (0.33 in.)

OBIS AccessoriesOBIS Remotes, Heat Sink, Power Supply and Accessories

OBIS Heat SinkPart#1193289

Fanincluded

Top View

Side ViewFront View Rear View

OBIS Single Laser Power SupplyPart#1184491

IncludedwithOBISSingleLaserRemote

PowerCordsoldseparately

104.4 mm(4.1 in.)

Cord Length:1219.2 mm

(48.0 in.)

Connector 2-Pin Male MolexP/N SDA43025-0200 2X Contact Pin Molex

P/N 43030-0009

IEC-320-C14Input Receptacle

Pin 112 VDC

Pin 2Ground

42 mm(1.7 in.)

31 mm(1.2 in.)

Front View

Top View

37Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 40: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS 6-Laser Remote Power SupplyPart#1211389

IncludedwithOBIS6-LaserRemote

189 mm(7.4 in.)

IEC-320-C14Input Receptacle

89.4 mm(3.5 in.)

Cord Length:1219.2 mm

(48 in.)

47.1 mm(1.9 in.)

OBIS AccessoriesOBIS Remotes, Heat Sink, Power Supply and Accessories

OBIS 6-Laser RemotePart#1203909 104.9 mm

(4.1 in.)

67.5 mm(2.7 in.)

9.2 mm(0.4 in.)2 Places

13.7 mm(0.5 in.)2 Places12 mm

(0.5 in.)2 Places

43.5 mm(1.7 in.)2 Places

32 mm(1.3 in.)

35.9 mm(1.4 in.)

4X #4-40 Threads2 Places, Near and Far Side

Top View

Side View

Rear View

Front View

38 www.Coherent.com • [email protected] Reliability & Performance •

Page 41: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS AccessoriesOBIS Remotes, Heat Sink, Power Supply and Accessories

126 mm(5.0 in.)

6.9 mm(0.3 in.)

6.4 mm(0.3 in.)

63.5 mm(2.5 in.) 50 mm

(2.0 in.)

139.9 mm(5.5 in.)

108.1 mm(4.3 in.)

37.8 mm(1.5 in.)

4X 8.1 mm(0.3 in.)

4X 7.1 mm(0.3 in.)

4X Slotted Holes

108.6 mm(4.3 in.)

75.7 mm(3.0 in.)

OBIS Remote Mounting Brackets and Stacking Brackets*IncludedwithOBISRemote

Front View

*AllowsOBISRemotetobemounted totabletopand/orstackedtogether.

Top View

Side ViewFront View

Side View

Top View

39Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 42: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Exampleshownmountedonlaser-canbemountedseparatelytoserveasalaseremissionwarninglight.

OBIS Laser Emission Indicator with Interlock ConnectorPart#1190901

PlugsintoOBISRemoteorOBIS6-LaserRemoteinterlockconnector.

5metercableandinterlockconnectorincluded.

Spare Parts KitPart#1190348

Coherent offers OBIS spare parts kit consisting of accessories for the OBIS that includes:OBISRemoteKey(2X)OBISRemoteInterlockMemoryStickforSoftwareControlandUserManualOBISLaserSafetyPamphletandQuickStartGuideOBISWavelengthLabelsOBISI/OCableOBISPowerCable(OEM)

OBIS AccessoriesOBIS Remotes, Heat Sink, Power Supply and Accessories

40 www.Coherent.com • [email protected] Reliability & Performance •

Page 43: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS AccessoriesOBIS Remotes, Heat Sink, Power Supply and Accessories

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all OBIS accessories. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Description Included Included with Included with Included with with OBIS Single OBIS Six Spare Parts Laser System Laser Remote Laser Remote Kit (Part#1173961) (Part#1203909) (Part#1190348)

LaserwithMountingBoltsandWashers xOBISSingleLaserRemote x xKeys(2),Interlock(Shorted),WavelengthLabel x x x xMemoryStickforSoftwareControlandUserManual x x x xMountingBracketsandHardwareforOBISRemote x x xUSBCable,1.8meter,TypeAtoTypeMiniB x xPowerSupply,110V/220VAC,12VDC,IEC-320 x x x Part#1184491 Part#1184491 Part#1211389Cable,SDR,Laser-to-Remote(1meter) x OrderSeparately, NotApplicable Part#1179451Cable,SDR,Laser-to-Remote(3meter) OrderSeparately,Part#1179858 NotApplicableCable,SDR,Laser-to-Remote(0.3meter) OrderSeparately,Part#1197523 NotApplicableCable,8-Pin,I/OforRemotewithleads(1meter) NotApplicable xCable,2-Pin,PowerConnectorwithleads(1meter) NotApplicable xHeatSink,includesCoolingFanandHardware OrderSeparately,Part#1193289LaserEmissionIndicatorwithInterlockConnector OrderSeparately,Part#1190901

Overview

41Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 44: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS Scientific RemoteOBIS Remote for Full Control of 6 OBIS Lasers with Touchscreen

Features

• Complete remote control of up to six OBIS lasers

• Touchscreen interface with audio

• Modulation inputs for analog and digital for six lasers

• USB, RS-232 and Ethernet for additional control from host computer

• OBIS connection software for PC

• Single SDR connection to each laser

• Internal power supply for power to remote and six lasers

• Laser safety features such as key switch and interlock

Mechanical Specifications

294 mm(11.6 in.)

Handle Width

183 mm(7.2 in.)

118 mm(4.6 in.)

259 mm(10.2 in.)

Handle LocationLOCKABLE IN 9 POSITIONS

30°Typical

Rear View

Front View

42 www.Coherent.com • [email protected] Reliability & Performance •

Page 45: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OBIS Scientific Remote OBIS Remote for Full Control of 6 OBIS Lasers with Touchscreen

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all OBIS Scientific Remotes. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

System Specifications TouchscreenDisplaySize 108mm(4.3in.)diagonalTouchscreenDisplayResolution,Type 480x272pixel,QVGA,TFT,24-bitcolorTouchscreenDisplayMode1 ResistiveTouchscreenAudio YesInternalPowerSupply YesOBISLasersthatcanbeconnected 1to6laserswithpowertooptional1to6heatsinkcoolingfansHostComputerRemoteControlviaUSB2 USB2.0,MiniBHostComputerRemoteControlviaRS-2322 RS-232115.2K,8N1HostComputerRemoteviaEthernet2 Ethernet10/100(Mb)RJ45CarryHandleandStand 3-PositionInterlock Yes,includedwithshortingwireLaserStatusIndicators Yes,IndividualLEDforeachlaserAnalogModulationInput SMB,50Ohm,0to5VDigitalModulationInput3 SMB,50Ohm,0to3VWarm-upTime(minutes)(fromcoldstart) <2OBISConnectionSoftware2 IncludedonUSBdrivewithusermanual

PowerConsumption(W)(typical) 5PowerConsumption(W)(maximum) 110InternalCoolingFan YesPowerInput-Universal IEC-320PowerCord(USA) 2.4m(8ft.)OperatingCondition4(°C) 0to40Non-OperatingCondition4(°C) -10to+70ShockTolerance(6ms) 20gOperatingVoltage 90to264VAC,47to63HzDimensions(LxWxH) 180x293.5x104.4mm(7.09x11.55x4.11in.)Weight 1.75kg(3.86lbs.)Weight,Laser-to-RemoteCable(optional) 0.1kgfor1meter(0.25kgfor3meter)PartNumberforOBISScientificRemote 1234465PartNumberforOBISScientificRemotewith 1234466SixLaser-to-RemoteSDRCablesIncluded(1meach)1 Resistivetouchscreenwillworkwithgloves.Thisisapressuresensitivetouchscreen-notcapacitive.2 Hostcomputernotprovided.RS-232andUSBcablenotprovided.SoftwareoperatesonWindows7.3 Digitalmodulationcanbedrivenupto5V.4 Non-condensing.

Utility and Environmental Requirements

Screen Shot

43Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 46: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

BioRayElliptical Dot Laser

Features

• 405 nm to 640 nm

• Power up to 50 mW

• External focusability

• Pointing <10 μrad/°C

• Analog modulation

• Microprocessor controlled

• Advanced service monitor

• RS-232 controllable with GUI interface

• Auto scaling input power 5 to 24 VDC

• ESD, Over Temp, Reverse Polarity

Mechanical Specifications

Hirose Plug

Indicator LightBeam Exit

4X 35.9 mm(1.41 in.)

2X 30.0 mm(1.18 in.)

2X 3.0 mm(0.12 in.)

2X 5.0 mm(0.2 in.)

4X Ø3.2 mm(0.13 in.)

Ø6.7 mm TYP.(0.27 in.)

14.4 mm(0.57 in.)15.5 mm

(0.61 in.)

40.0 mm(1.57 in.)

19.1 mm(0.75 in.)

16.9 mm(0.66 in.)

95.1 mm (3.74 in.) 1035 mm ±25.4(40.75 in. ±1.0)

50.8 mm (2.0 in.)

70.0 mm (2.76 in.)

2X 64.0 mm (2.52 in.)

8.5 mm(0.33 in.) 2.3 mm (0.09 in.)

Ø18.6 mm(0.73 in.)

34.3 mm(1.35 in.)

31.6 mm(1.24 in.)

31.4 mm(1.24 in.)

36.3 mm (1.43 in.)Clamping Area

Ø19.1 mm (0.75 in.)Clamping Area

Standard Configuration

Front View Rear View

Top View

Side View

Bottom View

44 www.Coherent.com • [email protected] Reliability & Performance •

Page 47: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications BioRay 405 450 488Wavelength1(nm) 405 450 488WavelengthTolerance(±nm) ±3 ±5 ±2WavelengthDrift(nm/°C) 0.06 0.06 0.03OutputPower(mW-Max.2) 50 50 20SpatialMode TEM00M2(BeamQuality)(Averagex,y3) <1.5BeamSize4(x,y) 2.3x1.2 2.4x0.8 2.5x1.2BeamDivergence4(mrad)(x,y) 0.5x0.5 0.4x0.8 0.4x0.6PointingStabilityOverTemp.(μrad/°C) <10RMSNoise(%)(20Hzto20MHz) <0.5Peak-to-PeakNoise(%)(20Hzto20MHz) <1Long-termPowerStability(%)(8hrs.,±3°C) <2Warm-upTime(minutes)(fromColdStart) <15LaserDriveModes AnalogAnalogModulation MaximumBandwidth(KHz) 500(ConstantPower) RiseTime(10%to90%)(nsec) <500 FallTime(90%to10%)(nsec) <500 ModulationDepth(%) 100 LinearRange(VDC) 0.5to5/0to4.5StaticBeamAlignment5(degrees) ±5OperatingVoltage(VDC) 5to24OperatingCurrent(mA)-(Max.at25°C) 100 160 85Connector6 HiroseHR-10P-12SSlowStartDelay7(sec.) 5InputImpedance(kOhm) 1.5BeamAngle(mrad) <3ESDProtection Level4HeatDissipationofLaserHead(W)(Max.) 5AmbientTemperature OperatingCondition(°C) 15to40 Non-operatingCondition(°C) -20to60ShockTolerance(g)(6ms) 301 CenterWavelengthat25°C.2 Deliveredpower.3 X=FastAxis,Y=SlowAxis.4 Typicalvalue.5 Slowaxisalignedtothebaseplate.6 FlyingleadforOEMconfiguration.7 Ifenabled.

45Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

BioRayElliptical Dot Laser

Page 48: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications BioRay 520 640Wavelength1(nm) 520 640WavelengthTolerance(±nm) ±5 ±3WavelengthDrift(nm/°C) 0.06 0.20OutputPower(mW-Max.2) 50 40SpatialMode TEM00M2(BeamQuality)(Averagex,y3) <1.5BeamSize4(x,y) 2.6x1.1 2.6x1.4BeamDivergence4(mrad)(x,y) 0.4x0.7 0.4x0.7PointingStabilityOverTemp.(μrad/°C) <10RMSNoise(%)(20Hzto20MHz) <0.5Peak-to-PeakNoise(%)(20Hzto20MHz) <1Long-termPowerStability(%)(8hrs.,±3°C) <2Warm-upTime(minutes)(fromColdStart) <15LaserDriveModes AnalogAnalogModulation MaximumBandwidth(KHz) 500(ConstantPower) RiseTime(10%to90%)(nsec) <500 FallTime(90%to10%)(nsec) <500 ModulationDepth(%) 100 LinearRange(VDC) 0.5to5/0to4.5StaticBeamAlignment5(degrees) ±5OperatingVoltage(VDC) 5to24OperatingCurrent(mA)-(Max.at25°C) 200 160Connector6 HiroseHR-10P-12SSlowStartDelay7(sec.) 5InputImpedance(kOhm) 1.5BeamAngle(mrad) <3ESDProtection Level4HeatDissipationofLaserHead(W)(Max.) 5AmbientTemperature OperatingCondition(°C) 15to40 Non-operatingCondition(°C) -20to60ShockTolerance(g)(6ms) 30

www.Coherent.com • [email protected] Reliability & Performance • 46

BioRayElliptical Dot Laser

1 CenterWavelengthat25°C.2 Deliveredpower.3 X=FastAxis,Y=SlowAxis.4 Typicalvalue.5 Slowaxisalignedtothebaseplate.6 FlyingleadforOEMconfiguration.7 Ifenabled.

Page 49: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Mechanical Specifications Weight(g) <70Length(mm) 95Diameter(mm) 19.05Material BlackannodizedAL6061T1

Commands DescriptionCDRH Enables/DisablesCDRHDelayBAUD SetBaudRateHAND Enables/DisablesSCPIHandshakingHOUR ReportsSystemLasingHoursMOD ReportsLaserModelPNUM ReportsPartNumberSNUM ReportsSerialNumberUSER StoresUserDefinedIdentificationPOW:LEV ReportsDiodeLaserPowerDIOD ReportsDiodeTemperatureINT ReportsInternalTemperatureHIGH ReportsDiodeHighTemperateSetMPOL SetsModulationPolarityAMPL SetsLaserOutputPowerSTAT ReportsSystemStatusCUR:LEV ReportsDiodeCurrent

Color Description Pin (optional Hirose connector)Red Vin 9Black VinGnd 1Green Fault 10White RS-232Recv 4White/Black RS-232Gnd 5Orange RS-232Trans 6Blue Vmod 2Red/Black VmodGnd 31 SeeUsersmanualforfullHostcommandset.

RS-232 Commands1

Pinout

32.5 mm (1.28 in.)Ø14 mm(0.55 in.)

Ø9.5 mm(0.37 in.)

47Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

BioRayElliptical Dot Laser

Page 50: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Fault Conditions Built-inmicrocontrollerprobesmostcriticalparametersofthecircuitwithADCssuchas: •Temperature •Photodiodeoutputvoltage •Laserdiodevoltage •Laserdiodecurrent •Valueofinvertedandnon-invertedmodulatingsignalincaseofStingRay-AMproductoptionsBasedontheresultsoftheparametermeasurementmicrocontrollercandetectfollowingfaultconditions •Overtemperature •Circuitmalfunction •Absenceoftheinputmodulatingsignal •CriticaldropoflaserdiodeoutputpowerduetoagingFaultoutputisanopencollectorofthetransistorthatallowswirejunctionORfunctionalitywithfaultsignalsfromotherdevices.Theoutputcantoleratevoltageupto30Vandcandrainthecurrentupto100mA.Thecircuitisprotectedfromovercurrentbyrecoverablefuse.TheloadshouldbeconnectedbetweenthevoltagesourceandtheopencollectoroutputasshownFigure1.

Figure 1

Fault Output Circuit

Modulation1 Timing

48 www.Coherent.com • [email protected] Reliability & Performance •

BioRayElliptical Dot Laser

FAULT

GND

Coherent BioRay Laser Power Supply <_30V

ILOAD <_100 mA

1 Lasersmusthaveloadappliedtothemodulationforproperoperation.

Vmod (V)

Nom

inal

Pow

er

00.10.20.30.40.50.60.70.80.91.0

0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

DirectModulationIndirectModulation

Laser Power vs. Analog Modulation

Modulation Fmax Direct (VDC) Inverse (VDC)

Analog 500KHz

0to0.5 4.5to5

OFF

0.5to5 0to4.5

LinearRegion

Page 51: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all BioRay lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

49Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

BioRayElliptical Dot Laser

External FocusAdjustment LockingSet Screw (No. 2-56)

External FocusAdjustment

External FocusAdjustment LockingSet Screw (No. 2-56)

2X 3.2 mm (0.13 in.) x 4.4 mm (0.18 in.)for No. 4-40 SHCS

External FocusAdjustment

2X No. 4-40 38.1 mm(1.5 in.)

25.4 mm(1.0 in.)

Beam Exit

Beam Exit

13.8 mm(0.5 in.)

13.8 mm(0.5 in.)

16.8 mm(0.7 in.)

16.8 mm(0.7 in.)

7.9 mm (0.3 in.)

31.8 mm(1.3 in.)

Ø18.64 mm(0.73 in.)

Ø18.64 mm(0.73 in.)

52.9 mm(2.1 in.)

52.9 mm(2.1 in.)

27.2 mm(1.1 in.)

68.2 mm(2.7 in.)

66.5 mm (2.6 in.) 0.5 m(1.6 ft.)

12.2 mm(0.5 in.)

0.5 m(1.6 ft.)

21.6 mm (0.9 in.)Clamping Area

Ø19.05 mm (0.75 in.)Clamping Area

36.3 mm (1.4 in.)

ClampingArea

Cable Length150 mm (5.9 in.)

Indicator Light

Indicator Light

Ø19.05 mm (0.75 in.)Clamping Area

21.6 mm (0.9 in.)Clamping Area

Ø19.05 mm (0.75 in.)Clamping Area

Cable Length150 mm (5.9 in.) Side View

Front ViewRear View

TopView

Mechanical Specifications

OEM Configuration

Page 52: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

BioRay FRMultimode Fiber-Ready Laser

Features

• 405 nm to 640 nm

• Power up to 35 mW Ex-fiber

• Analog modulation

• Microprocessor controlled

• Advanced service monitor

• RS-232 controllable with GUI interface

• Auto scaling input power 5 to 24 VDC

• ESD, Over Temp, Reverse Polarity

Mechanical Specifications

50 www.Coherent.com • [email protected] Reliability & Performance •

Hirose Plug

Indicator Light

2X 30.0 mm(1.18 in.)

2X 3.0 mm(0.12 in.)

2X 5.0 mm(0.2 in.)

4X Ø3.2 mm(0.13 in.)

3.1725 mm (0.1249 in.)3.1648 mm (0.1246 in.)Ø

9.812 mm (0.3863 in.)9.779 mm (0.3850 in.) Post Polish Length

Ø6.7 mm(0.27 in.)

22.3 mm(0.88 in.)

15.5 mm(0.61 in.)

40.0 mm(1.57 in.)

19.1 mm(0.75 in.)

25.0 mm(0.98 in.)

1035 mm ±25.4(40.75 in. ±1.0)

103.0 mm (4.06 in.)

50.8 mm (2.0 in.)

70.0 mm (2.76 in.)

2X 64.0 mm (2.52 in.)

8.5 mm(0.33 in.)

4X 35.9 mm(1.41 in.)

2.3 mm (0.09 in.)

Ø18.9 mm(0.75 in.)

34.3 mm(1.35 in.)

39.5 mm(1.56 in.)

31.4 mm(1.24 in.)

36.3 mm (1.43 in.)Clamping Area

Ø19.1 mm(0.75 in.)

Front View Rear View

Top View

Bottom View

Page 53: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications BioRay FR FR-405 FR-450 FR-488 FR-520 FR-640Wavelength1(nm) 405 450 488 520 640WavelengthTolerance(±nm) ±3 ±5 ±2 ±5 ±3WavelengthDrift(nm/°C) 0.06 0.06 0.03 0.06 0.20SpatialMode TEM00FiberConnector SMA905RMSNoise(%)(20Hzto20MHz) <0.5Peak-to-PeakNoise(%)(20Hzto20MHz) <1Long-termPowerStability(%)(8hrs.,±3°C) <2Warm-upTime(minutes)(fromColdStart) <15LaserDriveModes AnalogAnalogModulation MaximumBandwidth(KHz) 500(ConstantPower) RiseTime(10%to90%)(nsec) <500 FallTime(90%to10%)(nsec) <500 ModulationDepth(%) 100 LinearRange(VDC) 0.5to5/0to4.5OperatingVoltage(VDC) 5to24OperatingCurrent(mA)-(Max.at25°C) 100 160 85 200 160LaserConnector2 HiroseHR-10P-12SSlowStartDelay3(sec.) 5InputImpedance(kOhm) 1.5ESDProtection Level4HeatDissipationofLaserHead(W)(Max.) 5AmbientTemperature OperatingCondition(°C) 15to40 Non-operatingCondition(°C) -20to60ShockTolerance(g)(6ms) 301 CenterWavelengthat25°C.2 FlyingleadforOEMconfiguration.3 Ifenabled.

BioRay FR FR-405 FR-450 FR-488 FR-520 FR-640Wavelength(nm) 405 450 488 520 640OutputPower(mW) 50 50 20 50 40TypicalOutputPower2(ex-fiber,mW) 35 35 15 35 30CouplingEfficiencies(%) 72to75 72to75 75to78 77to80 80to83NumericalAperture3(NA)(1/e2) 0.22MinimumCoreDiameter(μm) 501 Thesecouplingefficienciesarenotguaranteedandshouldonlybeusedasguidelines.2 Deliveredpower.3 Typicalvalue.

51Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

BioRay FRMultimode Fiber-Ready Laser

Typicalcouplingefficienciesthatcanbeobtainedwithastepindexcorefiber,0.22NA,SMA/SMA,1meter(Coherentpartnumber1278782):

Coupling Efficiencies1

CE (%) = Pfiber x 100

Plaser

Page 54: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Mechanical Specifications Weight(g) <80FootPrint(LxWxH) 95x40x26mm(3.7x1.6x1.0in.)Material BlackannodizedAL6061T1

Commands DescriptionCDRH Enables/DisablesCDRHDelayBAUD SetBaudRateHAND Enables/DisablesSCPIHandshakingHOUR ReportsSystemLasingHoursMOD ReportsLaserModelPNUM ReportsPartNumberSNUM ReportsSerialNumberUSER StoresUserDefinedIdentificationPOW:LEV ReportsDiodeLaserPowerDIOD ReportsDiodeTemperatureINT ReportsInternalTemperatureHIGH ReportsDiodeHighTemperateSetSTAT ReportsSystemStatus

Color Description PinRed Vin 9Black VinGnd 1Green Fault 10White RS-232Recv 4White/Black RS-232Gnd 5Orange RS-232Trans 6Blue Vmod 2Red/Black VmodGnd 3

RS-232 Commands1

Pinout

BioRay FR SMA 905 Connector

52 www.Coherent.com • [email protected] Reliability & Performance •

BioRay FRMultimode Fiber-Ready Laser

1 Lasersmusthaveloadappliedtothemodulationforproperoperation.

32.5 mm (1.28 in.)Ø14 mm(0.55 in.)

Ø9.5 mm(0.37 in.)

Hirose Plug

Indicator Light

2X 30.0 mm(1.18 in.)

2X 3.0 mm(0.12 in.)

2X 5.0 mm(0.2 in.)

4X Ø3.2 mm(0.13 in.)

3.1725 mm (0.1249 in.)3.1648 mm (0.1246 in.)Ø

9.812 mm (0.3863 in.)9.779 mm (0.3850 in.) Post Polish Length

Ø6.7 mm(0.27 in.)

22.3 mm(0.88 in.)

15.5 mm(0.61 in.)

40.0 mm(1.57 in.)

19.1 mm(0.75 in.)

25.0 mm(0.98 in.)

1035 mm ±25.4(40.75 in. ±1.0)

103.0 mm (4.06 in.)

50.8 mm (2.0 in.)

70.0 mm (2.76 in.)

2X 64.0 mm (2.52 in.)

8.5 mm(0.33 in.)

4X 35.9 mm(1.41 in.)

2.3 mm (0.09 in.)

Ø18.9 mm(0.75 in.)

34.3 mm(1.35 in.)

39.5 mm(1.56 in.)

31.4 mm(1.24 in.)

36.3 mm (1.43 in.)Clamping Area

Ø19.1 mm(0.75 in.)

Page 55: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Fault Conditions Built-inmicrocontrollerprobesmostcriticalparametersofthecircuitwithADCssuchas: •Temperature •Photodiodeoutputvoltage •Laserdiodevoltage •Laserdiodecurrent •Valueofinvertedandnon-invertedmodulatingsignalincaseofStingRay-AMproductoptionsBasedontheresultsoftheparametermeasurementmicrocontrollercandetectfollowingfaultconditions •Overtemperature •Circuitmalfunction •Absenceoftheinputmodulatingsignal •Criticaldropoflaserdiodeoutputpowerduetoaging

FaultoutputisanopencollectorofthetransistorthatallowswirejunctionORfunctionalitywithfaultsignalsfromotherdevices.Theoutputcantoleratevoltageupto30Vandcandrainthecurrentupto100mA.Thecircuitisprotectedfromovercurrentbyrecoverablefuse.

TheloadshouldbeconnectedbetweenthevoltagesourceandtheopencollectoroutputasshownFigure1.

Figure 1

Fault Output Circuit

Modulation1 Timing

BioRay FRMultimode Fiber-Ready Laser

FAULT

GND

Coherent BioRay Laser Power Supply <_30V

ILOAD <_100 mA

1 Lasersmusthaveloadappliedtothemodulationforproperoperation.

Vmod (V)

Nom

inal

Pow

er

00.10.20.30.40.50.60.70.80.91.0

0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

DirectModulation

Laser Power vs. Analog Modulation

Modulation Fmax Direct (VDC)

Analog 500KHz

0to0.5

OFF

0.5to5

LinearRegion

53Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all BioRay lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Page 56: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

0.7600.75019.3019.05

SEE NOTE (A,B,C)

0.7500.7481Ø 9.0519.00

CLAMPING SURFACE

FC/APC FIBER CONNECTOR

SINGLE MODE FIBERLENGTH: 2M

PURE BEAM / FIBER OPTION

COLDRAY LASER OPTION1.7151.60543.5640.77

SEE NOTE (A,B,C)

0.7500.74819.0519.00

CLAMPING SURFACE

COLDRAY LASER

NOTE: (A) ADD 1.220 +0.010/-0.010 [31.0 +0.25/-0.25] FOR DIVERGING FLAT-TOP (1D AND 2D) (B) ADD 3.480 +0.020/-0.020 [88.4 +0.50/-0.50] FOR FLOW CYTOMETRY FLAT-TOP (C) ADD 0.890 +0.005/-0.005 [22.6 +0.12/-0.12] FOR FOCUSED FLAT-TOP

FREE SPACE OPTION

0.3040.2947.737.48

0.7500.74819.0519.00

SEE NOTE (A,B,C)

M14 x 0.5 THREADX 0.375 [9.50] DEEP.

in [mm]

Ø

Ø

0.7600.75019.3019.05

SEE NOTE (A,B,C)

0.7500.7481Ø 9.0519.00

CLAMPING SURFACE

FC/APC FIBER CONNECTOR

SINGLE MODE FIBERLENGTH: 2M

PURE BEAM / FIBER OPTION

COLDRAY LASER OPTION1.7151.60543.5640.77

SEE NOTE (A,B,C)

0.7500.74819.0519.00

CLAMPING SURFACE

COLDRAY LASER

NOTE: (A) ADD 1.220 +0.010/-0.010 [31.0 +0.25/-0.25] FOR DIVERGING FLAT-TOP (1D AND 2D) (B) ADD 3.480 +0.020/-0.020 [88.4 +0.50/-0.50] FOR FLOW CYTOMETRY FLAT-TOP (C) ADD 0.890 +0.005/-0.005 [22.6 +0.12/-0.12] FOR FOCUSED FLAT-TOP

FREE SPACE OPTION

0.3040.2947.737.48

0.7500.74819.0519.00

SEE NOTE (A,B,C)

M14 x 0.5 THREADX 0.375 [9.50] DEEP.

in [mm]

Ø

Ø

0.7600.75019.3019.05

SEE NOTE (A,B,C)

0.7500.7481Ø 9.0519.00

CLAMPING SURFACE

FC/APC FIBER CONNECTOR

SINGLE MODE FIBERLENGTH: 2M

PURE BEAM / FIBER OPTION

COLDRAY LASER OPTION1.7151.60543.5640.77

SEE NOTE (A,B,C)

0.7500.74819.0519.00

CLAMPING SURFACE

COLDRAY LASER

NOTE: (A) ADD 1.220 +0.010/-0.010 [31.0 +0.25/-0.25] FOR DIVERGING FLAT-TOP (1D AND 2D) (B) ADD 3.480 +0.020/-0.020 [88.4 +0.50/-0.50] FOR FLOW CYTOMETRY FLAT-TOP (C) ADD 0.890 +0.005/-0.005 [22.6 +0.12/-0.12] FOR FOCUSED FLAT-TOP

FREE SPACE OPTION

0.3040.2947.737.48

0.7500.74819.0519.00

SEE NOTE (A,B,C)

M14 x 0.5 THREADX 0.375 [9.50] DEEP.

in [mm]

Ø

Ø

Structured Light Flat Top ProjectorGaussian to Flat-Top Using Refractive Beam Shaping Optics

Features

• Very efficient all glass optics

• Achromatic (from UV to near IR)

• Very smooth low ripple uniformity profile with no high frequency noise

• Uniformity coefficient of variation of better than 1% achievable

• High aspect ratios available off the shelf

• High uniformity edge steepness

Mechanical Specifications

PureBeam/Fiber Option

ColdRay Laser Option

Free Space Option

Side View

Side View

Side ViewFront View

54 www.Coherent.com • [email protected] Reliability & Performance •

Page 57: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Structured Light Flat Top Projector Gaussian to Flat-Top Using Refractive Beam Shaping Optics

Complexflattoppatternscanbeachievedusingourbeamsplittingoption.

Theanglebetweeneachbeamisoperatingwavelengthdependentandcanbefoundviathegratingformula:dsinq=nl(d=periodinum,qangleindegrees,n=diffractionorder,0,+/-1,+/-2,....)

2Beams3(μm) 3.33,7.77,26.3,338.63Beams(μm) 3.33,7.77,26.3,338.65Beams(μm) 25,1699Beams(μm) 338.2,53211Beams(μm) 25.715Beams(μm) 16.419Beams(μm) 5033Beams(μm) 110,426.199Beams(μm) 260

Flat Top Options Theflattopisadivergingopticalelementthatprovidesauniformintensityprofileinthefarfield.Itcanbeimagedorofferedsimplyasadivergingopticalelement.

Beingcylinderbased,itcanbereadilyofferedactingononlyoneaxisorcrossedpairscreatingthedesiredaspectratioforyourapplication.

Thedimensionoftheflattopatthefocalplaneofanimaginglens,f,isdirectlyproportionaltoitseffectivefocallengthandcanbecalculatedby:

FTS(flattopsize)=2*tan(DIVERGENCE)*ƒ

TheflattopcanbefurtherenhancedbyaddingCoherent’sseriesofbinaryphasebeamsplitterstocreateacom-plexarrayofflattops.Thebeamsplittersarehighlystablebinarymastersetcheddirectlyinfusedsilicaofferingverylowstraylight.Theyhaveexcellentbeamtobeamuniformityandhaveefficienciesintheorderof80%.

Divergences1(±10%) 0.2,0.3,0.6,1,2,3,5,8,10,15,20,30FocalLength2 14,17.5,20,25,30,35,40,45,50,60,75,80,90,100

2

1 Availabledivergencesforoneandtwodimensionaldivergingflattops.2 Availablefocallengthsfortheimagedflattopsotion(l>400nm).Workingdistancewillbeafewmmshorter.3 Zeroorderminimized.

Gratings for Beam Splitting Option

Flat Top Generators

Flat Top 2D

Flat Top Matrix 2D

Flat Top 1D

Flat Top Matrix 1D

55Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Horizontalwidth(μm @ 1/e2)60

Verticalwidth(μm @ 1/e2)13

Horizontalwidth(μm @ 1/e2)Total4800Individual600

Verticalwidth(μm @ 1/e2)Total5500Individual200

Horizontalwidth(μm @ 1/e2)Total200

Verticalwidth(μm @ 1/e2)Total250Individual10

Horizontalwidth(μm @ 1/e2)200

Verticalwidth(μm @ 1/e2)600

Page 58: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Structured Light Flat Top Projector Gaussian to Flat-Top Using Refractive Beam Shaping Optics

Flat Top Options Coherenthasbeenverysuccessfulinpromotingitsflattopforflowcytometryapplications.Ourstandardflowcytometryoptionisavailablewiththefollowingspecifications:

WorkingDistance(mm) 45FlatTopDimension(umat1/e2) 60GaussianDimension(umat1/e2) 10ContainedPower(%) >60CVUniformity(%) <1fibercoupled,<1.5freespace

Dimensions1(mm) 0.5to4Wavelength2(nm) 400to1200GaussianFit(%) 97Mode TEM00Divergence Collimated/Quasicollimated

HighEfficiency1DimensionalFlatTopUniformity Containedpowertypical>85%HighUniformity1DimensionalFlatTopUniformity CVuniformitytypical<5%,downto<1%possible2DimensionalFlatTop CVuniformity<±20%,containedpower>85%TransmissionDivergingFlatTop Containedpower>95%TransmissionFocusedFlatTop Containedpower>90%1 Specifiedtowithin5%,largerinputbeamavailable.2 Otherwavelengthsavailable.

Input Beam Characteristics

X-AXIS Y-AXIS

Output Flat Top Characteristics

56 www.Coherent.com • [email protected] Reliability & Performance •

Page 59: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Structured Light Flat Top Projector Gaussian to Flat-Top Using Refractive Beam Shaping Optics

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Structured Light Flat Top Projectors. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Ordering Information

Toorder,usethefollowingcode:BSO-MODEL-Wavelength-POWER-Type-FT Size-WD(Note:SizeindegreesforDFT;sizeinμmforFFT;sizeinmmforWD).E.g.,BSO-FS-660-60-DFT-1x3(FreeSpacefor660nm60mWDivergingwithaFTsizeof1x3degrees).E.g.,BSO-CR-660-60-FFT-300x900-100(ColdRayfor660nm60mWFocusingwithaFTsizeof300x900μmat100mm).

InputType ColdRayLaserOption CoherentTECdirectsemiconductorfreespacelaser Ordercode:CR-Wavelength-PowerE.g.,CR-640-80) FreeSpaceOption M14threadedholder.Requiresinputbeamdimension(IBD): 0.5mmupto4mmGaussianat1/e2

Ordercode:FS-IBD(E.g.,FS-4) FiberOption FC/PCinputend,2mshielded,NA:0.12,FC/APCexitend. Requiresoperatingwavelengthbetween405-830nm Ordercode:FIB-Wavelength(E.g.,FIB-640)

FlatTopType OneDimensionalDivergingFlatTop Ordercode:1DDFT-Divergence(E.g.,1DDFT-0.3°) TwoDimensionalDivergingFlatTop Ordercode:2DDFT-Divergence1xDivergence2 (E.g.,2DDFT-0.3°x2°) ImagedFlatTop Ordercode:FFT-Divergence1xDivergence2-FocalLength (E.g.,FFT-0.3°x02°-F50)

BeamSplitterType Ordercode:Numberofbeams-Period(E.g.,19B-50μm)

57Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 60: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBEDiode Laser System

Features

• Compact and modular OEM design

• Superior beam quality

• Minimal laser output RMS noise

• Complete CDRH safety features for scientific and laboratory use

• TEC temperature-stabilized and conductively cooled through baseplate

• Analog and digital modulation

• USB and RS-232

Mechanical Specifications

30 mm(1.18 in.)20 mm

(0.79 in.)

5 mm(0.20 in.)

6 mm(0.25 in.)

90 mm(3.54 in.)

Ø4.2 mm(0.17 in.)

4 PLACES

Ø3 mm(0.118 in.)

Dowel Hole

Laser Aperture USB

DE-15

Digital ModulationSMB

3 x 7 mm(0.118 x 0.28 in.)Dowel Slot

5 mm(0.20 in.)

19 mm(0.75 in.)

15.5 mm(0.61 in.)

40 mm(1.58 in.)

40 mm(1.58 in.)

100 mm(3.94 in.)

5.1 mm(0.20 in.)

Top ViewLaser Head

Front View Rear View

58 www.Coherent.com • [email protected] Reliability & Performance •

Page 61: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE 375-16C 405-50C 405-100CPartNumber 1112774 1174298 1142279Wavelength1(nm) 375 405 405OutputPower2(mW) 16 50 100BeamDiameterat1/e2(mm)(typical) 1.1 1.4 1.4BeamDivergence(mrad)(typical) 0.5 0.4 0.4M2(ModeMasterbeamquality)3 <_1.3 <_1.3 <_1.2BeamAsymmetry3 <1:1.2LaserDriveModes Digital,AnalogandPCControlDigitalModulation MaximumBandwidth(MHz) 150 RiseTime(10%to90%)(nsec) <2 FallTime(10%to90%)(nsec) <2 ModulationDepth(extinctionratio) >1,000,000:1at0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 70 350 350 RiseorFallTime(10%to90%)(μsec) <5 <1 <1 ModulationDepth(extinctionratio) >10,000:1LaserEnableControlInput MaximumBandwidth(kHz) 130 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) ∞,completeOn/OffRMSNoise 20Hzto10MHz <_0.15% <_0.1% <_0.1% 10MHzto500MHz <1.0%Long-TermPowerStability(8hours) <±2%Warm-UpTime(minutes) <5SpatialMode(farfield) TEMooPointingStability(μrad/°C) <6PolarizationRatio4 Min.100:1,Vert.±5°StaticAlignmentTolerances5

BeamPosition(mm) <1 BeamAngle(mrad) <5CDRHLaserClassification ClassIIIbESDProtection6 Level4

CUBE Diode Laser System

System Specifications

1 Laser-to-lasertolerance.Alllasers±5nmexceptCUBE640-40with635to642nmrange,CUBE640-100with635to644nmrange, CUBE647-100with646to651nmrange,CUBE660with652to665nmrange,andCUBE785±10nm.2 OutputpowerisvariableviaRS-232,USBoranaloginterfacefrom1%to100%.Specificationsarevalidfor100%power. Recommendedpowerrangeis70%to100%power.3 M2andBeamAsymmetrymeasuredwithModeMasterwith90/10cliplevels.4 Polarizationmeasurementismax./min.powerwithpolarizerat32in.fromlaserwithLM-2powerheadat37in.fromlaser.5 Staticalignmenttolerancesarerelativetotherightbottomedge(inbeamdirection).6 Electro-StaticDischargeStandardIEC1000-4-2,1995.

59Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 62: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE 445-40C 488-50C 635-30EPartNumber 1069418 1174040 1069410Wavelength1(nm) 445 488 635OutputPower2(mW) 40 50 30BeamDiameterat1/e2(mm)(typical) 1.1 1.3 1x3.8BeamDivergence(mrad)(typical) 0.6 0.6 0.8x0.3M2(ModeMasterbeamquality)3 <_1.2 <_1.2 <_1.2BeamAsymmetry3 <1:1.2 <1:1.2 1:3.8LaserDriveModes Digital,AnalogandPCControlDigitalModulation MaximumBandwidth(MHz) 125 125 150 RiseTime(10%to90%)(nsec) <2 FallTime(10%to90%)(nsec) <3 <3 <2 ModulationDepth(extinctionratio) >1,000,000:1at0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 350 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) >10,000:1LaserEnableControlInput MaximumBandwidth(kHz) 130 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) ∞,completeOn/OffRMSNoise 20Hzto10MHz <_0.1% 10MHzto500MHz <1.0%Long-TermPowerStability(8hours) <±2%Warm-UpTime(minutes) <5SpatialMode(farfield) TEMooPointingStability(μrad/°C) <6PolarizationRatio4 Min.100:1,Vert.±5°StaticAlignmentTolerances5

BeamPosition(mm) <1 BeamAngle(mrad) <5CDRHLaserClassification ClassIIIbESDProtection6 Level4

CUBE Diode Laser System

System Specifications

1 Laser-to-lasertolerance.Alllasers±5nmexceptCUBE640-40with635to642nmrange,CUBE640-100with635to644nmrange, CUBE647-100with646to651nmrange,CUBE660with652to665nmrange,andCUBE785±10nm.2 OutputpowerisvariableviaRS-232,USBoranaloginterfacefrom1%to100%.Specificationsarevalidfor100%power. Recommendedpowerrangeis70%to100%power.3 M2andBeamAsymmetrymeasuredwithModeMasterwith90/10cliplevels.4 Polarizationmeasurementismax./min.powerwithpolarizerat32in.fromlaserwithLM-2powerheadat37in.fromlaser.5 Staticalignmenttolerancesarerelativetotherightbottomedge(inbeamdirection).6 Electro-StaticDischargeStandardIEC1000-4-2,1995.

60 www.Coherent.com • [email protected] Reliability & Performance •

Page 63: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE 640-40C 640-100C 647-100CPartNumber 1069417 1150205 1190357Wavelength1(nm) 640 640 647OutputPower2(mW) 40 100 100BeamDiameterat1/e2(mm)(typical) 1BeamDivergence(mrad)(typical) 1M2(ModeMasterbeamquality)3 <_1.2BeamAsymmetry3 <1:1.2LaserDriveModes Digital,AnalogandPCControlDigitalModulation MaximumBandwidth(MHz) 150 RiseTime(10%to90%)(nsec) <2 FallTime(10%to90%)(nsec) <2 ModulationDepth(extinctionratio) >1,000,000:1at0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 350 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) >10,000:1LaserEnableControlInput MaximumBandwidth(kHz) 130 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) ∞,completeOn/OffRMSNoise 20Hzto10MHz <_0.1% 10MHzto500MHz <1.0%Long-TermPowerStability(8hours) <±2%Warm-UpTime(minutes) <5SpatialMode(farfield) TEMooPointingStability(μrad/°C) <6PolarizationRatio4 Min.100:1,Vert.±5°StaticAlignmentTolerances5

BeamPosition(mm) <1 BeamAngle(mrad) <5CDRHLaserClassification ClassIIIbESDProtection6 Level4

CUBE Diode Laser System

System Specifications

1 Laser-to-lasertolerance.Alllasers±5nmexceptCUBE640-40with635to642nmrange,CUBE640-100with635to644nmrange, CUBE647-100with646to651nmrange,CUBE660with652to665nmrange,andCUBE785±10nm.2 OutputpowerisvariableviaRS-232,USBoranaloginterfacefrom1%to100%.Specificationsarevalidfor100%power. Recommendedpowerrangeis70%to100%power.3 M2andBeamAsymmetrymeasuredwithModeMasterwith90/10cliplevels.4 Polarizationmeasurementismax./min.powerwithpolarizerat32in.fromlaserwithLM-2powerheadat37in.fromlaser.5 Staticalignmenttolerancesarerelativetotherightbottomedge(inbeamdirection).6 Electro-StaticDischargeStandardIEC1000-4-2,1995.

61Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 64: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE 660-60C 660-100C 685-40CPartNumber 1094060 1130061 1184303Wavelength1(nm) 660 660 685OutputPower2(mW) 60 100 40BeamDiameterat1/e2(mm)(typical) 1.4 1 1BeamDivergence(mrad)(typical) 0.6 1 1M2(ModeMasterbeamquality)3 <_1.2BeamAsymmetry3 <1:1.2LaserDriveModes Digital,AnalogandPCControlDigitalModulation MaximumBandwidth(MHz) 150 RiseTime(10%to90%)(nsec) <2 FallTime(10%to90%)(nsec) <2 ModulationDepth(extinctionratio) >1,000,000:1at0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 350 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) >10,000:1LaserEnableControlInput MaximumBandwidth(kHz) 130 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) ∞,completeOn/OffRMSNoise 20Hzto10MHz <_0.1% 10MHzto500MHz <1.0%Long-TermPowerStability(8hours) <±2%Warm-UpTime(minutes) <5SpatialMode(farfield) TEMooPointingStability(μrad/°C) <6PolarizationRatio4 Min.100:1,Vert.±5°StaticAlignmentTolerances5

BeamPosition(mm) <1 BeamAngle(mrad) <5CDRHLaserClassification ClassIIIbESDProtection6 Level4

CUBE Diode Laser System

System Specifications

1 Laser-to-lasertolerance.Alllasers±5nmexceptCUBE640-40with635to642nmrange,CUBE640-100with635to644nmrange, CUBE647-100with646to651nmrange,CUBE660with652to665nmrange,andCUBE785±10nm.2 OutputpowerisvariableviaRS-232,USBoranaloginterfacefrom1%to100%.Specificationsarevalidfor100%power. Recommendedpowerrangeis70%to100%power.3 M2andBeamAsymmetrymeasuredwithModeMasterwith90/10cliplevels.4 Polarizationmeasurementismax./min.powerwithpolarizerat32in.fromlaserwithLM-2powerheadat37in.fromlaser.5 Staticalignmenttolerancesarerelativetotherightbottomedge(inbeamdirection).6 Electro-StaticDischargeStandardIEC1000-4-2,1995.

62 www.Coherent.com • [email protected] Reliability & Performance •

Page 65: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE 730-30C 785-40CPartNumber 1178855 1069416Wavelength1(nm) 730 785OutputPower2(mW) 30 40BeamDiameterat1/e2(mm)(typical) 1.2 1.2BeamDivergence(mrad)(typical) 0.9 1M2(ModeMasterbeamquality)3 <_1.2BeamAsymmetry3 <1:1.2LaserDriveModes Digital,AnalogandPCControlDigitalModulation MaximumBandwidth(MHz) 150 RiseTime(10%to90%)(nsec) <2 FallTime(10%to90%)(nsec) <2 ModulationDepth(extinctionratio) >1,000,000:1at0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 350 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) >10,000:1LaserEnableControlInput MaximumBandwidth(kHz) 130 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) ∞,completeOn/OffRMSNoise 20Hzto10MHz <_0.1% 10MHzto500MHz <1.0%Long-TermPowerStability(8hours) <±2%Warm-UpTime(minutes) <5SpatialMode(farfield) TEMooPointingStability(μrad/°C) <6PolarizationRatio4 Min.100:1,Vert.±5°StaticAlignmentTolerances5

BeamPosition(mm) <1 BeamAngle(mrad) <5CDRHLaserClassification ClassIIIbESDProtection6 Level41 Laser-to-lasertolerance.Alllasers±5nmexceptCUBE640-40with635to642nmrange,CUBE640-100with635to644nmrange, CUBE647-100with646to651nmrange,CUBE660with652to665nmrange,andCUBE785±10nm.2 OutputpowerisvariableviaRS-232,USBoranaloginterfacefrom1%to100%.Specificationsarevalidfor100%power. Recommendedpowerrangeis70%to100%power.3 M2andBeamAsymmetrymeasuredwithModeMasterwith90/10cliplevels.4 Polarizationmeasurementismax./min.powerwithpolarizerat32in.fromlaserwithLM-2powerheadat37in.fromlaser.5 Staticalignmenttolerancesarerelativetotherightbottomedge(inbeamdirection).6 Electro-StaticDischargeStandardIEC1000-4-2,1995.

CUBE Diode Laser System

System Specifications

63Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 66: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE Diode Laser System

Utility and Environmental Requirements

LaserHeadOperatingVoltage +4.8to6.5VDCLaserHeadOperatingCurrent <2.5ampsBaseplateTemperatureRange1 +10°to50°C(50°to122°F)MaximumHeatDissipationofHead(baseplateat50°C) 13WStorageTemperature -20°to60°C(-4°to140°F)PowerSupply2(included) OperatingVoltage3 100to240VAC,50to60Hz PowerConsumption <15W Dimensions (L x W x H) WeightLaserHead 100x40x40mm(3.9x1.6x1.6in.) 0.3kg(0.7lbs.)ControlBox 138x62x26mm(5.4x2.4x1.1in.) 0.12kg(0.3lbs.)PowerSupply 87x47x32mm(3.4x1.9x1.3in.) 0.22kg(0.5lbs.)HeadCable 254to406mm(10to18in.) 0.08kg(0.2lbs.)USBCable 1.8m(6ft.) 0.1kg(0.2lbs.)HeatSink(optional) 127x66x44mm(5x2.6x1.74in.) 0.4kg(0.9lbs.)1 Non-condensingwithlaserdiodeTECatsetpointof22°C.2 On-offpowerswitchandLEDincludedincordtolaserhead.3 SystemincludesUSA-typepowercord,IEC320inputconnection.

64 www.Coherent.com • [email protected] Reliability & Performance •

Page 67: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE Diode Laser System

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all CUBE lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

CUBE Accessories 1073840 CUBEHeatSinkAccessory CUBEheatsinkwithfan,127x66x44mm1079150 CUBE2ndEmissionLamp CDRHlampforlaseremission.ConnectstoCUBEI/Ocable.1072166 *CUBEInterfaceCable CUBEtocontrolbox,I/O,RS-232andpower1072454 *CUBEPowerSupply,6VDC,2.5amps IEC320input,110V/220V,switchandLED1108906 *CUBEUSBCable,6ft.(1.8m) USBstandardtominiforCUBE1039966 *ControlBox,CDRH,Keyswitch,Interlock ControlboxforCUBElasers.Includedbox,key,interlockRCAandcable.1080090 Cable,Extension,DB-9M/F,6ft.(1.8m) ExtensioncabletoextendcontrolboxorRS-232.M-F,DB-9.1040408 *Plug,RCA InterlockRCAplugforcontrolbox,non-shorted1079890 *CUBEManualandSoftware CUBEusermanualandsoftwareCDforWindows2000**andWindowsXP**1108063 *PowerCord,USA,6ft.(1.8m) Powercord,USAplugstyletoIEC3201116779 CUBEHeatSinkRightAngle CUBErightanglemount,102x47x44mm,samebeampositionwithhorizontalpolarization

Center of Laser Beam & Center

of Heat Sink

8-32 Accessory Mounting Holes on

0.5 and 1 in. Centers4 PLACES

M4 CUBEMounting Holes

4 PLACES

CUBEAlignment Pins

3 PLACES

75 mm

50 mm 2 in.

1 in. 3 in.

64 mm (2.50 in.)

66 mm (2.60 in.)

127 mm (5.0 in.)

44.2 mm (1.74 in.)

47 mm (1.85 in.)

Analog Control Input

BNC

86.5 mm (3.41 in.) Interlock RCA

Connection32 mm

(1.26 in.)

26 mm(1.� in.)

138 mm(5.4 in.)62 mm

(2.4 in.)

�28� mm Cor�(11.� in.)

�1.8 m Cor�(6 �t.)

47 mm (1.85 in.)

Analog Control Input

BNC

86.5 mm (3.41 in.) Interlock RCA

Connection32 mm

(1.26 in.)

26 mm(1.� in.)

138 mm(5.4 in.)62 mm

(2.4 in.)

�28� mm Cor�(11.� in.)

�1.8 m Cor�(6 �t.)

*IncludedfreewitheveryCUBEsystem. **Windows2000andWindowsXPareregisteredtrademarksofMicrosoftCorporation.

CUBE Heat Sink

CUBE Control Box

CUBE Power Supply

Heat Sink Top View

65Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 68: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

USB

1 m (minimum)(39 in.)

40 mm(1.58 in.)

40 mm(1.58 in.)

5.1 mm(0.2 in.)

100 mm(3.94 in.)

50 mm(2.0 in.)

1 m (minimum)(39 in.)

90 mm(3.54 in.)

5 mm(0.2 in.)

30 mm(1.18 in.)

6 mm(0.24 in.)

12 mm(0.47 in.)

Stainless Steel Jacket

3 x 7 mm(0.118 x 0.28 in.)

Dowel SlotØ4.2 mm(0.17 in.)3 Places

(0.25 in.)

5 mm(0.2 in.)

DE-15

Digital ModulationSMB

FC Connector Key

Polish DirectionAxis ±4° Max.

Vertical Polarization±2° Max.

View of Fiber from Connector End

Angle Polished 8 ±0.5°

.20 mm ±0.10 mm

8.0°3 mm PVC Furcation Tubing

FC Connector KeyType R - Narrow Key(2.0 mm +0.02/-0.03 mm Key Width)

8.0°

CUBE FPDiode Laser System

Features

• Permanent fiber attachment – constant power without adjustments

• Compact and modular OEM design

• Complete CDRH safety features for scientific and laboratory use

• TEC temperature-stabilized and conductively cooled through baseplate

• Analog and digital modulation

• USB and RS-232

Mechanical Specifications

Rear View

Top View(FC/APC)

Top View(Collimated Beam)

Front View

66 www.Coherent.com • [email protected] Reliability & Performance •

Page 69: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE FP 405-50FP 405-50FPPartNumber 1139602 1139601OutputfromFiber FC/APC(8°angled)6 CollimatedBeamFiberCableType 3mmPVC StainlessSteelFiberCableLength(m)(minimum) 1 1Wavelength1(nm) 405 405OutputPower2(mW) 50 50BeamDiameter(1/e2)(mm)(typical) - 1BeamDivergence(mrad)(typical) - 1FiberNumericalAperture(NA)(1/e2) 0.05 -Mode-fieldDiameter(μm)(typical) 3.5M2(ModeMasterbeamquality) <_1.1BeamAsymmetry <_1:1.1LaserDriveModes Digital,AnalogandPCControlDigitalModulation MaximumBandwidth(MHz) 150 150 RiseTime(10%to90%)(nsec) <2 <2 FallTime(10%to90%)(nsec) <2 <2 ModulationDepth(extinctionratio) >1,000,000:1at0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 350 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) >10,000:1LaserEnableControlInput MaximumBandwidth(kHz) 130 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) ∞,completeOn/OffRMSNoise 20Hzto10MHz <0.2% 10MHzto500MHz <1.0%PowerStability(8hours,±3°C) <_±2%Long-TermOutputPowerAverage <_5%/1000hrs.Warm-UpTime(minutes) <5SpatialMode(farfield) TEMooPointingStability(μrad/°C) - <6PolarizationRatio3 Minimum100:1Tolerances4

BeamPosition(mm) - <_0.5 BeamAngle(mrad) - <_15CDRHLaserClassification ClassIIIbESDProtection5 Level41 Laser-to-lasertolerance.CUBE640-30hascenterwavelengthrangeof635nmto642nm,CUBE640-75with635nmto644nmrange, CUBE660with652nmto665nmrange,CUBE405,445and488with±5nmrange.2 OutputpowerisvariableviaRS-232,USBoranaloginterfacefrom1%to100%.Specificationsarevalidfor100%to110%power. Recommendedpowerrangeis70%to100%power.Factorysetting100%to110%ofpowerspecification.3 Polarizationmeasurementismax./min.powerwithpolarizerat32cmfromlaserwithLM-2powerheadat37cmfromlaser.4 Staticalignmenttolerancesarerelativetocenterofoutputbeamaperture.5 Electro-StaticDischargeStandardIEC1000-4-2,1995.6 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.

CUBE FPDiode Laser System

System Specifications

67Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 70: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE FP Diode Laser System

System Specifications CUBE FP 445-25FP 445-25FPPartNumber 1169225 1169224OutputfromFiber FC/APC(8°angled)6 CollimatedBeamFiberCableType 3mmPVC StainlessSteelFiberCableLength(m)(minimum) 1 1Wavelength1(nm) 445 445OutputPower2(mW) 25 25BeamDiameter(1/e2)(mm)(typical) - 1BeamDivergence(mrad)(typical) - 1FiberNumericalAperture(NA)(1/e2) 0.05 -Mode-fieldDiameter(μm)(typical) 3.5M2(ModeMasterbeamquality) <_1.1BeamAsymmetry <_1:1.1LaserDriveModes Digital,AnalogandPCControlDigitalModulation MaximumBandwidth(MHz) 125 RiseTime(10%to90%)(nsec) <2 FallTime(10%to90%)(nsec) <3 ModulationDepth(extinctionratio) >1,000,000:1at0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 350 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) >10,000:1LaserEnableControlInput MaximumBandwidth(kHz) 130 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) ∞,completeOn/OffRMSNoise 20Hzto10MHz <0.2% 10MHzto500MHz <1.0%PowerStability(8hours,±3°C) <_±2%Long-TermOutputPowerAverage <_5%/1000hrs.Warm-UpTime(minutes) <5SpatialMode(farfield) TEMooPointingStability(μrad/°C) - <6PolarizationRatio3 Minimum100:1Tolerances4

BeamPosition(mm) - <_0.5 BeamAngle(mrad) - <_15CDRHLaserClassification ClassIIIbESDProtection5 Level41 Laser-to-lasertolerance.CUBE640-30hascenterwavelengthrangeof635nmto642nm,CUBE640-75with635nmto644nmrange, CUBE660with652nmto665nmrange,CUBE405,445and488with±5nmrange.2 OutputpowerisvariableviaRS-232,USBoranaloginterfacefrom1%to100%.Specificationsarevalidfor100%to110%power. Recommendedpowerrangeis70%to100%power.Factorysetting100%to110%ofpowerspecification.3 Polarizationmeasurementismax./min.powerwithpolarizerat32cmfromlaserwithLM-2powerheadat37cmfromlaser.4 Staticalignmenttolerancesarerelativetocenterofoutputbeamaperture.5 Electro-StaticDischargeStandardIEC1000-4-2,1995.6 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.

68 www.Coherent.com • [email protected] Reliability & Performance •

Page 71: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE FPDiode Laser System

System Specifications CUBE FP 488-30FP 488-30FPPartNumber 1169223 1169222OutputfromFiber FC/APC(8°angled)6 CollimatedBeamFiberCableType 3mmPVC StainlessSteelFiberCableLength(m)(minimum) 1 1Wavelength1(nm) 488 488OutputPower2(mW) 30 30BeamDiameter(1/e2)(mm)(typical) - 1BeamDivergence(mrad)(typical) - 1FiberNumericalAperture(NA)(1/e2) 0.05 -Mode-fieldDiameter(μm)(typical) 3.5M2(ModeMasterbeamquality) <_1.1BeamAsymmetry <_1:1.1LaserDriveModes Digital,AnalogandPCControlDigitalModulation MaximumBandwidth(MHz) 125 RiseTime(10%to90%)(nsec) <2 FallTime(10%to90%)(nsec) <3 ModulationDepth(extinctionratio) >1,000,000:1at0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 350 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) >10,000:1LaserEnableControlInput MaximumBandwidth(kHz) 130 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) ∞,completeOn/OffRMSNoise 20Hzto10MHz <0.2% 10MHzto500MHz <1.0%PowerStability(8hours,±3°C) <_±2%Long-TermOutputPowerAverage <_5%/1000hrs.Warm-UpTime(minutes) <5SpatialMode(farfield) TEMooPointingStability(μrad/°C) - <6PolarizationRatio3 Minimum100:1Tolerances4

BeamPosition(mm) - <_0.5 BeamAngle(mrad) - <_15CDRHLaserClassification ClassIIIbESDProtection5 Level41 Laser-to-lasertolerance.CUBE640-30hascenterwavelengthrangeof635nmto642nm,CUBE640-75with635nmto644nmrange, CUBE660with652nmto665nmrange,CUBE405,445and488with±5nmrange.2 OutputpowerisvariableviaRS-232,USBoranaloginterfacefrom1%to100%.Specificationsarevalidfor100%to110%power. Recommendedpowerrangeis70%to100%power.Factorysetting100%to110%ofpowerspecification.3 Polarizationmeasurementismax./min.powerwithpolarizerat32cmfromlaserwithLM-2powerheadat37cmfromlaser.4 Staticalignmenttolerancesarerelativetocenterofoutputbeamaperture.5 Electro-StaticDischargeStandardIEC1000-4-2,1995.6 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.

69Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 72: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE FP Diode Laser System

System Specifications CUBE FP 640-30FP 640-30FP 640-75FP 640-75FPPartNumber 1139604 1139603 1169221 1169220OutputfromFiber FC/APC(8°angled) CollimatedBeam FC/APC(8°angled) CollimatedBeamFiberCableType 3mmPVC StainlessSteel 3mmPVC StainlessSteelFiberCableLength(m)(minimum) 1 1 1 1Wavelength1(nm) 640 640 640 640OutputPower2(mW) 30 30 75 75BeamDiameter(1/e2)(mm)(typical) - 1 - 1BeamDivergence(mrad)(typical) - 1 - 1FiberNumericalAperture(NA)(1/e2) 0.09 - 0.09 -Mode-fieldDiameter(μm)(typical) 4.5 - 4.5 -M2(ModeMasterbeamquality) <_1.1BeamAsymmetry <_1:1.1LaserDriveModes Digital,AnalogandPCControlDigitalModulation MaximumBandwidth(MHz) 150 RiseTime(10%to90%)(nsec) <2 FallTime(10%to90%)(nsec) <2 ModulationDepth(extinctionratio) >1,000,000:1at0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 350 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) >10,000:1LaserEnableControlInput MaximumBandwidth(kHz) 130 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) ∞,completeOn/OffRMSNoise 20Hzto10MHz <0.2% 10MHzto500MHz <1.0%PowerStability(8hours,±3°C) <_±2%Long-TermOutputPowerAverage <_3%/1000hrs.Warm-UpTime(minutes) <5SpatialMode(farfield) TEMooPointingStability(μrad/°C) - <6 - <6PolarizationRatio3 Minimum80:1Tolerances4

BeamPosition(mm) - <_0.5 - <_0.5 BeamAngle(mrad) - <_15 - <_15CDRHLaserClassification ClassIIIbESDProtection5 Level41 Laser-to-lasertolerance.CUBE640-30hascenterwavelengthrangeof635nmto642nm,CUBE640-75with635nmto644nmrange, CUBE660with652nmto665nmrange,CUBE405,445and488with±5nmrange.2 OutputpowerisvariableviaRS-232,USBoranaloginterfacefrom1%to100%.Specificationsarevalidfor100%to110%power. Recommendedpowerrangeis70%to100%power.Factorysetting100%to110%ofpowerspecification.3 Polarizationmeasurementismax./min.powerwithpolarizerat32cmfromlaserwithLM-2powerheadat37cmfromlaser.4 Staticalignmenttolerancesarerelativetocenterofoutputbeamaperture.5 Electro-StaticDischargeStandardIEC1000-4-2,1995.6 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.

70 www.Coherent.com • [email protected] Reliability & Performance •

Page 73: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE FPDiode Laser System

System Specifications CUBE FP 660-75FP 660-75FPPartNumber 1151423 1151422OutputfromFiber FC/APC(8°angled) CollimatedBeamFiberCableType 3mmPVC StainlessSteelFiberCableLength(m)(minimum) 1 1Wavelength1(nm) 660 660OutputPower2(mW) 75 75BeamDiameter(1/e2)(mm)(typical) - 1BeamDivergence(mrad)(typical) - 1FiberNumericalAperture(NA)(1/e2) 0.09 -Mode-fieldDiameter(μm)(typical) 4.5M2(ModeMasterbeamquality) <_1.1BeamAsymmetry <_1:1.1LaserDriveModes Digital,AnalogandPCControlDigitalModulation MaximumBandwidth(MHz) 150 RiseTime(10%to90%)(nsec) <2 FallTime(10%to90%)(nsec) <2 ModulationDepth(extinctionratio) >1,000,000:1at0Hz,>250:1at150MHzAnalogModulation MaximumBandwidth(kHz) 350 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) >10,000:1LaserEnableControlInput MaximumBandwidth(kHz) 130 RiseorFallTime(10%to90%)(μsec) <1 ModulationDepth(extinctionratio) ∞,completeOn/OffRMSNoise 20Hzto10MHz <0.2% 10MHzto500MHz <1.0%PowerStability(8hours,±3°C) <_±2%Long-TermOutputPowerAverage <_3%/1000hrs.Warm-UpTime(minutes) <5SpatialMode(farfield) TEMooPointingStability(μrad/°C) - <6PolarizationRatio3 Minimum80:1Tolerances4

BeamPosition(mm) - <_0.5 BeamAngle(mrad) - <_15CDRHLaserClassification ClassIIIbESDProtection5 Level41 Laser-to-lasertolerance.CUBE640-30hascenterwavelengthrangeof635nmto642nm,CUBE640-75with635nmto644nmrange, CUBE660with652nmto665nmrange,CUBE405,445and488with±5nmrange.2 OutputpowerisvariableviaRS-232,USBoranaloginterfacefrom1%to100%.Specificationsarevalidfor100%to110%power. Recommendedpowerrangeis70%to100%power.Factorysetting100%to110%ofpowerspecification.3 Polarizationmeasurementismax./min.powerwithpolarizerat32cmfromlaserwithLM-2powerheadat37cmfromlaser.4 Staticalignmenttolerancesarerelativetocenterofoutputbeamaperture.5 Electro-StaticDischargeStandardIEC1000-4-2,1995.6 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.

71Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 74: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE FPDiode Laser System

Utility and Environmental Requirements

LaserHeadOperatingVoltage +4.8to6.5VDCLaserHeadOperatingCurrent <2.5ampsBaseplateTemperatureRange1 +10°to50°C(50°to122°F)MaximumHeatDissipationofHead(baseplateat50°C) 13WStorageTemperature -20°to60°C(-4°to140°F)PowerSupply2(included) OperatingVoltage3,PowerConsumption 100to240VAC(50to60Hz),<15W Dimensions (L x W x H) WeightLaserHead 100x40x40mm(3.9x1.6x1.6in.) 0.4kg(0.9lbs.)LaserHeadwithMinimumFiberBendRadius 203mm(8.0in.)FiberTensileLoad(max.) 1kg(2.2lbs.)FiberMinimumBendRadius 51mm(2.0in.)ControlBox 138x62x26mm(5.4x2.4x1.1in.) 0.12kg(0.3lbs.)PowerSupply 87x47x32mm(3.4x1.9x1.3in.) 0.22kg(0.5lbs.)HeadCable 254to406mm(10to18in.) 0.08kg(0.2lbs.)USBCable 1.8m(6ft.) 0.1kg(0.2lbs.)HeatSink(optional-soldseparately) 127x66x44mm(5x2.6x1.74in.) 0.4kg(0.9lbs.)1 Non-condensingwithlaserdiodeTECatsetpointof22°C.2 On-offpowerswitchandLEDincludedincordtolaserhead.3 SystemincludesUSA-typepowercord,IEC320inputconnection.

72 www.Coherent.com • [email protected] Reliability & Performance •

Page 75: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

CUBE FPDiode Laser System

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all CUBE lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

CUBE Accessories 1073840 CUBEHeatSinkAccessory CUBEheatsinkwithfan,127x66x44mm,metric/English1079150 CUBE2ndEmissionLamp CDRHlampforlaseremission.ConnectstoCUBEI/Ocable.1072166 *CUBEInterfaceCable CUBEtocontrolbox,I/O,RS-232andpower1072454 *CUBEPowerSupply,6VDC,2.5amps IEC320input,110V/220V,switchandLED1108906 *CUBEUSBCable,6ft.(1.8m) USBstandardtominiforCUBE1039966 *ControlBox,CDRH,Keyswitch,Interlock ControlboxforCUBElasers.Includedbox,key,interlockRCAandcable.1080090 Cable,Extension,DB-9M/F,6ft.(1.8m) ExtensioncabletoextendcontrolboxorRS-232.M-F,DB-91040408 *Plug,RCA InterlockRCAplugforcontrolbox,non-shorted1150553 *CUBEFPManual CUBEusermanualandsoftwareCDforWindows2000**andWindowsXP**1108063 *PowerCord,USA,6ft.(1.8m) Powercord,USAplugstyletoIEC320*IncludedfreewitheveryCUBEsystem. **Windows2000andWindowsXPareregisteredtrademarksofMicrosoftCorporation.

66 mm (2.60 in.)

127 mm (5.0 in.)

44.2 mm (1.74 in.)

8-32 Accessory Mounting Holes on

0.5 and 1 in. Centers4 PLACES

M4 CUBEMounting Holes

3 PLACES

CUBEAlignment Pins

3 PLACES

75 mm

50 mm 2 in.

1 in. 3 in.

47 mm (1.85 in.)

Analog Control Input

BNC

86.5 mm (3.41 in.) Interlock RCA

Connection32 mm

(1.26 in.)

26 mm(1.0 in.)

138 mm(5.4 in.)62 mm

(2.4 in.)

~280 mm Cord(11.0 in.)

~1.8 m Cord(6 ft.)

47 mm (1.85 in.)

Analog Control Input

BNC

86.5 mm (3.41 in.) Interlock RCA

Connection32 mm

(1.26 in.)

26 mm(1.0 in.)

138 mm(5.4 in.)62 mm

(2.4 in.)

~280 mm Cord(11.0 in.)

~1.8 m Cord(6 ft.)

CUBE Heat Sink

Heat Sink Top View

CUBE Control Box

CUBE Power Supply

73Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 76: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

44.5 mm (1.75 in.)

218 mm (8.6 in.)

76 mm (3.0 in.)

64 mm (2.5 in.)

Including bend radius

146 mm (5.8 in.)

~1 m cord

43 mm(1.7 in.)

Interlock RCA Connection

26 mm(1.0 in.)

138 mm(5.4 in.)62 mm

(2.4 in.)

~280 mm cord(11.0 in.)

RadiusDiode Laser System

Features

• HeNe cylindrical-style package

• All-in-one design: optics, electronics and TEC

• Adjustable beam option

• ESD protection

• Internal cooling fan

• CDRH Class IIIb safety compliance option

• Constant power CW

Mechanical Specifications Laser Head

Power Supply Control Box

74 www.Coherent.com • [email protected] Reliability & Performance •

Page 77: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Radius Diode Laser System

System Specifications Radius 635-25 635-25EWavelength(nm) 635+7/-2 635+7/-2Power(mW) 25 25Max.ModulationFrequency(Hz) 100 100RMSNoise(10Hzto10MHz) <0.5% <0.5%PowerStability(8Hours) <2% <2%AdjustableBeamFocus(Divergence) No YesStaticAlignmentTolerances1 <15mrad(angle) <5mrad(angle)Polarization(Horizontal) >100:1 >100:1CDRHClass ClassIIIb ClassIIIbSpotSize(mm)(typical) 1 1.5x4.6Divergence(mrad)(typical) 1.3 0.5x0.2PartNumberforSystemwithControlBoxincluded 1051385 –PartNumberforSystemwithoutControlBox2 1008053 1149819

LaserDrive CW,ConstantPowerPointingStability <6μrad/°CBeamSpatialMode(FarField) TEMooESDProtection4 Level4Dimensions(DiameterxLength) 44.5x218mm(1.75x8.6in.)OptionalControlBox(LxWxH) 138x62x26mm(5.4x2.4x1in.)AmbientTemperatureRangeforOperation5 10°Cto40°C(50°Fto104°F)StorageTemperature -20°Cto60°C(-4°Fto140°F)MaximumHeatLoadfromLaserHead 10W,typical3W

PowerSupplyincludedwithSystem YesWeight 570g(1.25lbs.)Dimensions(LxWxH) 146x76x43mm(5.8x3.0x1.7in.)OutputtoLaserHead +5VDC,-5VDC,+12VDCCordLengthtoLaserHead 120cm(48in.)ACInputVoltage6 100to240VAC,47to63HzACInputPower <15W

1039966 ControlBox,CDRH,Keyswitch,InterlockControlBoxforRadiuslasers.Includedbox,key,interlockRCAandcable.1080090 Cable,Extension,DB-9M/F,6ft.(1.8m) Extensioncabletoextendcontrolbox.Male-Female,DB-9.1040408 Plug,RCA InterlockRCAplugforControlBox,non-shorted1059300 PowerSupply,LDM,110/220VAC RadiusorULN,Desktop,43Watt,TripleOutput

Laser Head Specifications

Power Supply Specifications

1 Staticalignmenttolerancesarerelativetothelaser’soutsidediameter.2 SystemsthatdonotincludethecontrolboxdonotcomplywiththeFederalRegulations(21CFRSubchapterJ)asadministeredbytheCenterforDevices andRadiologicalHealth.Purchaseracknowledgesthathis/herproductsmustcomplywiththeseregulationsbeforetheycanbesoldtoacustomer.3 ModulationthroughsidepanelI/Oport.ViaTTLsignalwith400KOhminputimpedance(VH>4V,VL<3V);TTLneedstobeappliedforminimumof 10msecforRadius635and100msecfor375/405/440.4 Electro-StaticDischargeStandardIEC1000-4-2,1995.5 Non-condensing.6 ShippedwithUSApowercord,IEC320inputconnection.

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Radius lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

75Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 78: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

ULNDiode Laser Modules

Features

• Ultra-low noise (ULN)

• RMS noise <0.06% for bandwidths of 10 Hz to 10 MHz

• Circular beam

• No mode-hop noise

• No warm-up period

• Wavelength 635 nm with 5 mW CW power

• Long lifetime

Mechanical Specifications

LabLaser

135 mm(5.31 in.)

460 mm(18.11 in.)

19.05 mm ±0.08(0.75 in. ±0.003)

Front Diameter22.1 mm typical(0.87 in. typical) NOTE: Line generator modules (0220-936-00 and 31-0268-000)

do not included shutter.

4.8 mm(0.19 in.)

5.3 mm(0.21 in)

15.4 mm(0.61 in.)

76 www.Coherent.com • [email protected] Reliability & Performance •

Page 79: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

ULN Diode Laser Modules

System Specifications LabLaser™ 635 nm 5 mW C ULNWavelength(nm) 635+7/-2Power(mW) 5CDRHClass ClassIIIb,Non-ConformingSpotSize(mm) 1Divergence(mrad) 1LaserDrive ULN,Ultra-LowNoisePowerSupply IncludedConnector 5-pinDINPartNumber 31-0144-000

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all ULN diode laser modules. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

77Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 80: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

2 mm(0.08 in.)

10 mm(0.39 in.)

40 mm(1.58 in.)

4 m

m(0

.16

in.)

19 m

m(0

.75

in.)

33.1

mm

(1.3

in.)

47 m

m(1

.85

in.)

40 m

m(1

.58

in.)

40 mm(1.58 in.)

Ø55

mm

(2.1

65 in

.)

Ø3.5 mm(0.138 in.)

100 mm (4.0 in.)

Beam Axis

60 mm (2.36 in.)

Compass 115MCW Green Lasers

Features

• Best performance-to-price ratio

• Excellent laser beam parameters

• Reliable by design

• Highest unit-to-unit consistency

• Unsurpassed lifetime

• Lowest cost of ownership

Mechanical Specifications

Laser Head – Side View Standalone Controller

Laser Head – Rear View

On-Top Controller

Laser Head – Top View

78 www.Coherent.com • [email protected] Reliability & Performance •

Page 81: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Compass 115MCW Green Lasers

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Compass lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Specifications Wavelength(nm) 532OutputPower(mW) Compass115M-5 5 Compass115M-10 10 Compass115M-15 15 Compass115M-20 20SpatialMode TEM00M2 <1.2CircularityofBeam >90%,<1.1:1BeamDiameter@1/e2(mm) 0.32±15%BeamDivergence(mrad) <3PointingStability(μrad/°C) <6Noise(10Hzto1MHz)(rms) <0.5%Long-TermPowerStability(over8hours) <5%Warm-UpTime(min.) <5PolarizationRatio 100:1,verticalStaticAlignmentTolerances BeamPosition1(mm) ±1 BeamAngle(mrad) ±2.5

OperatingVoltage2(VDC) 5to6PowerConsumption(W) <25MaximumPowerConsumption(W) LaserHead <15 Controller <10MaximumLaserHeadBaseplateTemperature 45°C(113°F)forConductiveCoolingStorageTemperature -20°Cto60°C(-4°Fto140°F)Dimensions(LxWxH) LaserHead 100x55x33.5mm(4.0x2.2x1.3in.) On-TopController 138x40x40mm(5.4x1.6x1.6in.) Stand-AloneController(optional) 140x92.5x14.5mm(5.5x3.6x0.6in.) PowerSupply(optional) 174x107x43mm(6.9x4.2x1.7in.) Cable—LaserHeadtoController 1m(3.3ft.)Weights LaserHead 0.15kg(0.33lbs.) On-TopController 0.1kg(0.22lbs.) Stand-AloneController(optional) 0.2kg(0.44lbs.) PowerSupply(optional) 0.7kg(1.54lbs.) Cable—LaserHeadtoController 0.25kg(0.55lbs.)

EnvironmentalSpecifications

Specificationsarevalidfornominalpower.1 Staticalignmenttolerancesarerelativetotheleftedgeofthelaserheadboardinbeamdirection.2 Thepowersupplymustmeetthefollowingrequirements. DCVoltage 5to6V Power 50W Ripple <5%peak-to-peak3 Pricingformeasurementtoolscanbeobtainedthroughyourlocalsalesrepresentative.

79Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 82: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Sapphire LPCW Visible Lasers from Deep Blue to Orange

15 mm(0.6 in.)

17.9 mm(0.7 in.)

17.5 mm(0.69 in.)

6.1 mm(0.24 in.)

20.4 mm(0.8 in.)

11 mm(0.43 in.)

16.7 mm(0.66 in.)

0 m

m (0

.0 in

.)

5.1

mm

(0.2

in.)

21.1

mm

(0.8

in.)

35.3

mm

(1.4

in.)

62.6

mm

(2.5

in.)

102.

9 m

m (4

.0 in

.)

112.

4 m

m (4

.4 in

.)

117.

8 m

m (4

.6 in

.)

8.3 mm(0.327 in.)

66 mm(2.6 in.)

76.2 mm(3.0 in.)

8.8 mm (0.345 in.)

6.35 mm(0.25 in.)

app.

35 mm(1.38 in.)

max.

6.1 mm(0.24 in.)

6 spacers with tapped threadM4, UNC #8 or 5/32 BSWare attached

USB-InterfaceMini USB-Type B5 pol

Serial InterfaceDSub-9 (female)

Analog Interface26 pin-headertype AMP latchTyco 281275-1

Laser Head DSub-25 (female)

Fuse TE5 5A 127V Littlefuse 3961500000

DC Power ConnectorMolex Micro Fit 3.0 10 positions

5 mm (0.2 in.)

10 mm (0.4 in.)

110 mm(4.3 in.)

115.6 mm (4.5 in.)

120 mm (4.7 in.)

125 mm (4.9 in.)

7.5 mm(0.3 in.)

19 mm(0.75 in.)

34 mm(1.3 in.)

BeamExit

6 mm(0.24 in.)

70 mm(2.75 in.)

55 mm(2.2 in.)

45 mm(1.8 in.)

Position of Dowel Pins(Beam Registering)

LED(Emission Indicator)

Connection to Controller(25pin SUB-D male)

DC Supply for Fan(AMP-MODU-2pin-male)

Interfacing Part (Heatsink) should haveflatness <0.05 mm (0.002 in.)

Beam Waist at Exit Window[3 mm (0.12 in.) inside from here][±200 mm (7.9 in.)]

4 Holes Ø4.0 mm (0.16 in.)for Screws M3, UNC/UNF No.5&6,1/8-40 BSW/BSF or BA No.4&5

Mechanical Specifications

Laser Head

Side View Side ViewRear View

Top View Top View

FrontView

Controller

Features

• Wavelength versatility - 458 nm to 594 nm

• Broad spectrum of output power - 10 mW up to 300 mW

• Outstanding power stability and low noise

• Superior beam quality

• Flexible interface concept - Analog, RS-232 & USB

• PermAlign technology - Permanent optimal alignment - Unsurpassed robust and stable

• Proven reliability - More than 35,000 installations

• OEM and end-user versions

80 www.Coherent.com • [email protected] Reliability & Performance •

Page 83: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications

Utility and Environmental Requirements

Measurement Tools

Sapphire 458 LP 488 LPWavelength1(nm) 458±2 488±2OutputPower2(mW) 20,50,75 10,20,25,30,40,50 75,100,150,200,300SpatialMode TEM00,M2<1.1BeamAsymmetry 0.9to1.1BeamDiameterat1/e2 0.70±0.05mmBeamDivergence(mrad) <1.2PointingStability(over2hoursafterwarm-upand±3°C)(μrad) <30Noise(%) 20Hzto2MHz,rms <0.25 20Hzto20kHz,peak-to-peak <1Long-TermPowerStability(%)(2hours,±3°C) <2Warm-UpTime(minutes) <5PolarizationRatio >100:1,verticalStaticAlignmentTolerances3

BeamPosition(mm) ±0.25 BeamAngle(mrad) ±2.5 BeamWaistPositionatExitWindow ±2004

OperatingVoltage5(VDC) +10.8to15PowerConsumption(W) <60Max.LaserHeadBaseplateTemp.6 +50°C(122°F) +55°C(131°F),+50°C(122°F)7

Max.HeatDissipationofHead(W) 25(baseplateat50°C) 25(baseplateat55°C/50°C)7

AmbientTemperature OperatingConditions 10to40°C(50to104°F)non-condensing Non-OperatingCondition -30to60°C(-22to140°F)ShockTolerance(6ms) 7glaterally,15gverticallyDimensions(LxWxH) LaserHead 125x70x34mm(4.9x2.8x1.3in.) Controller 117.8x76.2x30mm(4.6x3.0x1.2in.) HeatSink(optional) 200x80x50mm(7.9x3.2x2in.) DCPowerSupply(optional) 171x104x55mm(6.7x4.1x2.2in.) Cable—LaserHeadtoController 2m(6.56ft.),optional5m(16.4ft.)Weights LaserHead 0.35kg(0.77lbs.) Controller 0.25kg(0.55lbs.) HeatSink(optional) 0.75kg(1.65lbs.) DCPowerSupply(optional) 0.95kg(incl.linecable)(2.1lbs.) PackagedSystem(head+controller+cable+manual) 1.7kg(3.7lbs.) Cable—LaserHeadtoController 0.3kg(0.66lbs.)

PartNumberMeter FieldMax™II-TO 1098579Sensor PS10Q 10984001 Laser-to-lasertolerance.WithresidualIRemissionlessthan0.1mW.2 Outputpowerisadjustableviaanalogordigitalinterfacefrom10%to110%.Specificationsarevalidfor100%power.Recommendedpower rangeis70to110%power.3 Staticalignmenttolerancesarerelativetotherightbottomedge(inbeamdirection).4 200mmis~30%ofRaleighRangeat514/532/561/568nm;200mmis~25%ofRaleighRangeat458/488nm.5 Ifuser-supplied,theDCpowersupplyhastomeetthefollowingrequirements:Power>60W;ripple<5%peak-to-peak;lineregulation<0.5%.6 Withfactory-providedorotheradequateheatsink.7 Sapphire488-10/20/25/30hasamaximumbaseplatetemperatureof+55°C(+131°F).Sapphire488-40/50/75/100/150/200and300mW modelsarelimitedtoamaximumbaseplatetemperatureof+50°C(+122°F).

Sapphire LPCW Visible Lasers from Deep Blue to Orange

81Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 84: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications

Utility and Environmental Requirements

Measurement Tools

Sapphire 514 LP 532 LP 552 LPWavelength1(nm) 514±2 532±2 552±2OutputPower2(mW) 20,50,75, 20,50,75,100, 50,75,100 100,150 150,200,300 150,200SpatialMode TEM00,M2<1.1BeamAsymmetry 0.9to1.1BeamDiameterat1/e2 0.70±0.05mmBeamDivergence(mrad) <1.3PointingStability(over2hoursafterwarm-upand±3°C)(μrad) <30Noise(%) 20Hzto2MHz,rms <0.25 20Hzto20kHz,peak-to-peak <1Long-TermPowerStability(%)(2hours,±3°C) <2Warm-UpTime(minutes) <5PolarizationRatio >100:1,verticalStaticAlignmentTolerances3

BeamPosition(mm) ±0.25 BeamAngle(mrad) ±2.5 BeamWaistPositionatExitWindow ±2004

OperatingVoltage5(VDC) +10.8to15PowerConsumption(W) <60Max.LaserHeadBaseplateTemp.6 +50°C(122°F)Max.HeatDissipationofHead(W) 25(baseplateat50°C)AmbientTemperature OperatingConditions 10to40°C(50to104°F)non-condensing Non-OperatingCondition -30to60°C(-22to140°F)ShockTolerance(6ms) 7glaterally,15gverticallyDimensions(LxWxH) LaserHead 125x70x34mm(4.9x2.8x1.3in.) Controller 117.8x76.2x30mm(4.6x3.0x1.2in.) HeatSink(optional) 200x80x50mm(7.9x3.2x2in.) DCPowerSupply(optional) 171x104x55mm(6.7x4.1x2.2in.) Cable—LaserHeadtoController 2m(6.56ft.),optional5m(16.4ft.)Weights LaserHead 0.35kg(0.77lbs.) Controller 0.25kg(0.55lbs.) HeatSink(optional) 0.75kg(1.65lbs.) DCPowerSupply(optional) 0.95kg(incl.linecable)(2.1lbs.) PackagedSystem(head+controller+cable+manual) 1.7kg(3.7lbs.) Cable—LaserHeadtoController 0.3kg(0.66lbs.)

PartNumberMeter FieldMax™II-TO 1098579Sensor PS10Q 10984001 Laser-to-lasertolerance.WithresidualIRemissionlessthan0.1mW.2 Outputpowerisadjustableviaanalogordigitalinterfacefrom10%to110%.Specificationsarevalidfor100%power.Recommendedpower rangeis70to110%power.3 Staticalignmenttolerancesarerelativetotherightbottomedge(inbeamdirection).4 200mmis~30%ofRaleighRangeat514/532/561/568nm;200mmis~25%ofRaleighRangeat458/488nm.5 Ifuser-supplied,theDCpowersupplyhastomeetthefollowingrequirements:Power>60W;ripple<5%peak-to-peak;lineregulation<0.5%.6 Withfactory-providedorotheradequateheatsink.

Sapphire LPCW Visible Lasers from Deep Blue to Orange

82 www.Coherent.com • [email protected] Reliability & Performance •

Page 85: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications

Utility and Environmental Requirements

Measurement Tools

Sapphire 561 LP 568 LP 588 LP 594 LPWavelength1(nm) 561±2 568±2 588±2 594±2OutputPower2(mW) 20,50,75,100, 50,75,100, 20,50,75,100 20,50,75 150,200,300 150,200SpatialMode TEM00,M2<1.1BeamAsymmetry 0.9to1.1BeamDiameterat1/e2 0.70±0.05mmBeamDivergence(mrad) <1.3PointingStability(over2hoursafterwarm-upand±3°C)(μrad) <30Noise(%) 20Hzto2MHz,rms <0.25 20Hzto20kHz,peak-to-peak <1Long-TermPowerStability(%)(2hours,±3°C) <2Warm-UpTime(minutes) <5PolarizationRatio >100:1,verticalStaticAlignmentTolerances3

BeamPosition(mm) ±0.25 BeamAngle(mrad) ±2.5 BeamWaistPositionatExitWindow ±2004

OperatingVoltage5(VDC) +10.8to15PowerConsumption(W) <60Max.LaserHeadBaseplateTemp.6 +50°C(122°F)Max.HeatDissipationofHead(W) 25(baseplateat50°C)AmbientTemperature OperatingConditions 10to40°C(50to104°F)non-condensing Non-OperatingCondition -30to60°C(-22to140°F)ShockTolerance(6ms) 7glaterally,15gverticallyDimensions(LxWxH) LaserHead 125x70x34mm(4.9x2.8x1.3in.) Controller 117.8x76.2x30mm(4.6x3.0x1.2in.) HeatSink(optional) 200x80x50mm(7.9x3.2x2in.) DCPowerSupply(optional) 171x104x55mm(6.7x4.1x2.2in.) Cable—LaserHeadtoController 2m(6.56ft.),optional5m(16.4ft.)Weights LaserHead 0.35kg(0.77lbs.) Controller 0.25kg(0.55lbs.) HeatSink(optional) 0.75kg(1.65lbs.) DCPowerSupply(optional) 0.95kg(incl.linecable)(2.1lbs.) PackagedSystem(head+controller+cable+manual) 1.7kg(3.7lbs.) Cable—LaserHeadtoController 0.3kg(0.66lbs.) PartNumberMeter FieldMax™II-TO 1098579Sensor PS10Q 10984001 Laser-to-lasertolerance.WithresidualIRemissionlessthan0.1mW.2 Outputpowerisadjustableviaanalogordigitalinterfacefrom10%to110%.Specificationsarevalidfor100%power.Recommendedpower rangeis70to110%power.3 Staticalignmenttolerancesarerelativetotherightbottomedge(inbeamdirection).4 200mmis~30%ofRaleighRangeat514/532/561/568nm;200mmis~25%ofRaleighRangeat458/488nm.5 Ifuser-supplied,theDCpowersupplyhastomeetthefollowingrequirements:Power>60W;ripple<5%peak-to-peak;lineregulation<0.5%.6 Withfactory-providedorotheradequateheatsink.

Sapphire LPCW Visible Lasers from Deep Blue to Orange

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Sapphire lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

83Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 86: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Sapphire FPFiber Pigtailed Lasers from Deep Blue to Orange

Features

• Wavelength versatility -458 nm to 594 nm

• Powers: up to 200 mW

• Outstanding power stability

• Low noise

• Broad ambient temperature range: operational and non-operational

• PermAlign and fiber-pigtail technology - Permanent optimal alignment - Unsurpassed robust and stable

• Flexible interface concept - Analog, RS-232 & USB

• Unsurpassed reliability and lifetime

6.1 mm(0.24 in.)

20.4 mm(0.8 in.)

11 mm(0.43 in.)

16.7 mm(0.66 in.)

0 m

m (0

.0 in

.)

5.1

mm

(0.2

in.)

21.1

mm

(0.8

in.)

35.3

mm

(1.4

in.)

62.6

mm

(2.5

in.)

102.

9 m

m (4

.0 in

.)

112.

4 m

m (4

.4 in

.)

117.

8 m

m (4

.6 in

.)

8.3 mm(0.327 in.)

66 mm(2.6 in.)

76.2 mm(3.0 in.)

8.8 mm (0.345 in.)

6.35 mm(0.25 in.)

app.

35 mm(1.38 in.)

max.

6.1 mm(0.24 in.)

6 spacers with tapped threadM4, UNC #8 or 5/32 BSWare attached

USB-InterfaceMini USB-Type B5 pol

Serial InterfaceDSub-9 (female)

Analog Interface26 pin-headertype AMP latchTyco 281275-1

Laser Head DSub-25 (female)

Fuse TE5 5A 127V Littlefuse 3961500000

DC Power ConnectorMolex Micro Fit 3.0 10 positions

6 mm (0.24 in.)

7.5 mm (0.3 in.)

125 mm (4.92 in.)

115 mm (4.53 in.)

40.5 mm (1.59 in.)

5 mm(0.2 in.)

17.9 mm (0.7 in.)

34 m

m

(1.3

4 in

.)

19 mm (0.75 in.)

70 m

m (2

.76

in.)

55 m

m (2

.17

in.)

Ø6.2 mm (0.24 in.)

Mechanical Specifications

Laser Head

Side View

Top View

Side View

Top View

Front View

Controller

84 www.Coherent.com • [email protected] Reliability & Performance •

Page 87: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications Sapphire 458FP 488FPWavelength1(nm) 458±2 488±2OutputPoweratFiberExit2(mW) 40 40,80,120,200FiberType SM-PM3

FiberLength(m) 1FiberOutput FC/APC;8°angled4

SpatialMode TEM00,M2<1.1BeamAsymmetry <1:1.1Noise(%) RMS(20Hzto2MHz) <0.25 Peak-to-PeakNoise(20Hzto20kHz) <1Long-TermPowerStability(%)(2hours,±3°C) <2Warm-UpTime(min.) <5PolarizationRatio >100:1,linear,vertical

LaserSafetyClassification 3bOperatingVoltage5(VDC) +10.8to15PowerConsumption(W) <60Max.LaserHeadBaseplateTemperature6 50°C/122°FMax.HeatDissipationofLaserHead(W) 25(baseplateat50°C/122°F)AmbientTemperature OperatingCondition 10to40°C/50to104°F Non-OperatingCondition -20to60°C/-4to140°FHumidity OperatingCondition 0to95%,non-condensing Non-OperatingCondition 0to100%,non-condensingShockTolerance(11ms) 15glaterally,15gverticallyDimensions(LxWxH) LaserHead7 125x70x34mm/4.9x2.8x1.3in. Controller 118x76x30mm/4.6x3.0x1.2in. HeatSink(optional) 200x80x50mm/7.9x3.2x2.0in. DCPowerSupply(optional) 171x104x55mm/6.7x4.1x2.2in. CableLaserHeadtoController 2m/6.56ft.andoptionsWeights LaserHead7 0.35kg/0.77lbs. Controller 0.25kg/0.55lbs. HeatSink(optional) 0.75kg/1.65lbs. DCPowerSupply(optional) 0.95kg/2.1lbs.incl.linecable CableLaserHeadtoController 0.3kg/0.66lbs.1 Laser-to-lasertolerance.2 Outputpowerisadjustableviaanalogordigitalinterfacefrom10%to110%.Specificationsarevalidfor100%power.3 Single-mode,polarizationmaintainingfiber,bendingradiusmin.50mm.4 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.5 Ifuser-supplied,theDCpowersupplyhastomeetthefollowingrequirements:power>60W;ripple<5%peak-to-peak;lineregulation<0.5%.6 Withfactory-providedorotheradequateheatsink.7 Dimensionsrespectivelyweightwithoutfiber-pigtailpart.

Utility and Environmental Requirements

Sapphire FP Fiber Pigtailed Lasers from Deep Blue to Orange

85Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 88: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications Sapphire 514FP 532FP 552FPWavelength1(nm) 514±2 532±2 552±2OutputPoweratFiberExit2(mW) 40,80,120 40,80,120 40,80,120FiberType SM-PM3

FiberLength(m) 1FiberOutput FC/APC;8°angled4

SpatialMode TEM00,M2<1.1BeamAsymmetry <1:1.1Noise(%) RMS(20Hzto2MHz) <0.25 Peak-to-PeakNoise(20Hzto20kHz) <1Long-TermPowerStability(%)(2hours,±3°C) <2Warm-UpTime(min.) <5PolarizationRatio >100:1,linear,vertical

LaserSafetyClassification 3bOperatingVoltage5(VDC) +10.8to15PowerConsumption(W) <60Max.LaserHeadBaseplateTemperature6 50°C/122°FMax.HeatDissipationofLaserHead(W) 25(baseplateat50°C/122°F)AmbientTemperature OperatingCondition 10to40°C/50to104°F Non-OperatingCondition -20to60°C/-4to140°FHumidity OperatingCondition 0to95%,non-condensing Non-OperatingCondition 0to100%,non-condensingShockTolerance(11ms) 15glaterally,15gverticallyDimensions(LxWxH) LaserHead7 125x70x34mm/4.9x2.8x1.3in. Controller 118x76x30mm/4.6x3.0x1.2in. HeatSink(optional) 200x80x50mm/7.9x3.2x2.0in. DCPowerSupply(optional) 171x104x55mm/6.7x4.1x2.2in. CableLaserHeadtoController 2m/6.56ft.andoptionsWeights LaserHead7 0.35kg/0.77lbs. Controller 0.25kg/0.55lbs. HeatSink(optional) 0.75kg/1.65lbs. DCPowerSupply(optional) 0.95kg/2.1lbs.incl.linecable CableLaserHeadtoController 0.3kg/0.66lbs.1 Laser-to-lasertolerance.2 Outputpowerisadjustableviaanalogordigitalinterfacefrom10%to110%.Specificationsarevalidfor100%power.3 Single-mode,polarizationmaintainingfiber,bendingradiusmin.50mm.4 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.5 Ifuser-supplied,theDCpowersupplyhastomeetthefollowingrequirements:power>60W;ripple<5%peak-to-peak;lineregulation<0.5%.6 Withfactory-providedorotheradequateheatsink.7 Dimensionsrespectivelyweightwithoutfiber-pigtailpart.

Utility and Environmental Requirements

Sapphire FP Fiber Pigtailed Lasers from Deep Blue to Orange

86 www.Coherent.com • [email protected] Reliability & Performance •

Page 89: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications Sapphire 561FP 588FP 594FPWavelength1(nm) 561±2 588±2 594±2OutputPoweratFiberExit2(mW) 40,80,120,200 40 40FiberType SM-PM3

FiberLength(m) 1FiberOutput FC/APC;8°angled4

SpatialMode TEM00,M2<1.1BeamAsymmetry <1:1.1Noise(%) RMS(20Hzto2MHz) <0.25 Peak-to-PeakNoise(20Hzto20kHz) <1Long-TermPowerStability(%)(2hours,±3°C) <2Warm-UpTime(min.) <5PolarizationRatio >100:1,linear,vertical

LaserSafetyClassification 3bOperatingVoltage5(VDC) +10.8to15PowerConsumption(W) <60Max.LaserHeadBaseplateTemperature6 50°C/122°FMax.HeatDissipationofLaserHead(W) 25(baseplateat50°C/122°F)AmbientTemperature OperatingCondition 10to40°C/50to104°F Non-OperatingCondition -20to60°C/-4to140°FHumidity OperatingCondition 0to95%,non-condensing Non-OperatingCondition 0to100%,non-condensingShockTolerance(11ms) 15glaterally,15gverticallyDimensions(LxWxH) LaserHead7 125x70x34mm/4.9x2.8x1.3in. Controller 118x76x30mm/4.6x3.0x1.2in. HeatSink(optional) 200x80x50mm/7.9x3.2x2.0in. DCPowerSupply(optional) 171x104x55mm/6.7x4.1x2.2in. CableLaserHeadtoController 2m/6.56ft.andoptionsWeights LaserHead7 0.35kg/0.77lbs. Controller 0.25kg/0.55lbs. HeatSink(optional) 0.75kg/1.65lbs. DCPowerSupply(optional) 0.95kg/2.1lbs.incl.linecable CableLaserHeadtoController 0.3kg/0.66lbs.1 Laser-to-lasertolerance.2 Outputpowerisadjustableviaanalogordigitalinterfacefrom10%to110%.Specificationsarevalidfor100%power.3 Single-mode,polarizationmaintainingfiber,bendingradiusmin.50mm.4 FiberFC/APCconnectoroutputnotcompatibleforpatchcord-to-patchcordconnection.5 Ifuser-supplied,theDCpowersupplyhastomeetthefollowingrequirements:power>60W;ripple<5%peak-to-peak;lineregulation<0.5%.6 Withfactory-providedorotheradequateheatsink.7 Dimensionsrespectivelyweightwithoutfiber-pigtailpart.

Utility and Environmental Requirements

Sapphire FP Fiber Pigtailed Lasers from Deep Blue to Orange

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Sapphire FP lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

87Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 90: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Sapphire SFCW Blue and Green Single-Frequency Lasers

Features

• Ultra-narrow linewidth

• High single-frequency power - Up to 100 mW at 488 nm - Up to 150 mW at 532 nm

• Outstanding power stability

• Ultra-low noise, esp. no discharge background or green noise (cf. ion, diode, DPSS lasers)

• Superior beam quality

• Flexible interface concept - Analog, RS-232 & USB

• PermAlign technology - Permanent optimal alignment - Unsurpassed robust and stable

• OEM and end-user versions

• Proven Sapphire reliability

Mechanical Specifications

Laser Head Controller

88 www.Coherent.com • [email protected] Reliability & Performance •

15 mm(0.6 in.)

17.9 mm(0.7 in.)

17.5 mm(0.69 in.)

43.2 mm(1.7 in.)

97.8 mm(3.85 in.)

14.2 mm(0.56 in.)

5.9 mm(0.23 in.)

117.8 mm(4.64 in.)

5 mm (0.2 in.)

10 mm (0.4 in.)

110 mm(4.3 in.)

115.6 mm (4.5 in.)

120 mm (4.7 in.)

125 mm (4.9 in.)

7.5 mm(0.3 in.)

19 mm(0.75 in.)

34 mm(1.3 in.)

BeamExit

6 mm(0.24 in.)

70 mm(2.75 in.)

55 mm(2.2 in.)

66 mm(2.6 in.)

76.2 mm(3.0 in.)

45 mm(1.8 in.)

Position of Dowel Pins(Beam Registering)

LED(Emission Indicator)

Connection to Controller(25pin SUB-D male)

DC Supply for Fan(AMP-MODU-2pin-male)

Interfacing Part (Heatsink) should haveflatness <0.05 mm (0.002 in.)

4X M4 3.5 mm (0.14 in.)

Beam Waist at Exit Window[3 mm (0.12 in.) inside from here][±200 mm (7.9 in.)]

4 Holes Ø4.0 mm (0.16 in.)for Screws M3, UNC/UNF No.5&6,1/8-40 BSW/BSF or BA No.4&5

Front View

Rear View Side View

Top View

Top View

Side View

Page 91: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

System Specifications Sapphire 488SF 532SFWavelength(nm) 488 532WavelengthAccuracy(nm) 0.1Single-longitudinalMode,Linewidth(MHz) <1.5OutputPower1(mW) 20,50,100 20,50,100,150SpatialMode TEM00,M2<1.1,singlelongitudinalmodeBeamAsymmetry 0.9to1.1BeamDiameterat1/e2(mm) 0.70±0.05BeamDivergence(mrad) <1.3PointingStability(over2hoursafterwarm-upand±3°C)(μrad) <30Noise(%) 20Hzto2MHz,rms <0.25 20Hzto20kHz,peak-to-peak <1Long-termPowerStability(%)(2hours,±3°C) <2Warm-upTime(minutes) <5PolarizationRatio >100:1,verticalStaticAlignmentTolerances2

BeamPosition(mm) ±0.25 BeamAngle(mrad) ±2.5 BeamWaistPositionwithrespecttoExitWindow ±2003

Interfacing Analog,RS-232,USBOperatingVoltage4(VDC) +10.8to15PowerConsumption(W) <60Max.LaserHeadBaseplateTemp.5 +50°C(122°F)Max.HeatDissipationofHead(W) 25(baseplateat50°C)AmbientTemperature OperatingConditions10to40°C(50to104°F)non-condensing Non-OperatingCondition-30to60°C(-22to140°F)ShockTolerance(6ms) 7glaterally,15gverticallyDimensions(LxWxH) LaserHead 125x70x34mm(4.9x2.8x1.3in.) Controller 117.8x76.2x43.2mm(4.6x3.0x1.7in.) HeatSink(optional) 200x80x50mm(7.9x3.2x2in.) DCPowerSupply(optional) 172x105x55mm(6.8x4.1x2.2in.) Cable—LaserHeadtoController 2m(6.56ft.),optional5m(16.4ft.)Weights LaserHead 0.35kg(0.77lbs.) Controller 0.25kg(0.55lbs.) HeatSink(optional) 0.75kg(1.65lbs.) DCPowerSupply(optional) 0.95kg(incl.linecable)(2.1lbs.) PackagedSystem(head+controller+cable+manual) 1.7kg(3.7lbs.) Cable—LaserHeadtoController 0.3kg(0.66lbs.)

Meter FieldMax™II-TO 1098579Sensor PS10Q 10984001 Outputpowerisadjustableviaanalogordigitalinterfacefrom10%to110%.Specificationsarevalidfor100%power. Recommendedpowerrangeis70to110%power.2 Staticalignmenttolerancesarerelativetotherightbottomedge(inbeamdirection).3 200mmis~25%ofRaleighRangeat488nmand~30%ofRaleighRangeat532nm.4 Ifuser-supplied,theDCpowersupplyhastomeetthefollowingrequirements:Power>60W;ripple<5%peak-to-peak;lineregulation<0.5%.5 Withfactory-providedorotheradequateheatsink.

Utility and Environmental Requirements

Measurement Tools

Sapphire SF CW Blue and Green Single-Frequency Lasers

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Sapphire SF lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

89Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 92: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Sapphire Driver UnitOperate, Control and Monitor Sapphire Laser Heads

Features

• One-box wall plug controller and power supply

• Enables stand-alone applications (CDRH Compliant)

• Standby/Laser ON key switch

• Remote interlock

• Remote control option via Analog, RS-232, or USB interface

• Laser power adjustment and graphic display (optional)

• Front panel control with laser power adjustment and status display (optional)

• Status LEDs

196 mm(7.72 in.)

90 mm(3.54 in.)

164 mm(6.46 in.)

9.5 mm(0.37 in.)

KeySwitch

Mechanical Specifications

Front View(Display Version)

(Non-Display Version)

Side ViewRear View

(Display Version)

(Non-Display Version)

Top View

90 www.Coherent.com • [email protected] Reliability & Performance •

Page 93: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Sapphire Driver UnitOperate, Control and Monitor Sapphire Laser Heads

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Sapphire lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Utility and Environmental Requirements

Theoptionallaseremissionindicatorislocatedattheendofa5m(16.4ft.)cablewhichconnectstotherearpanelofthedriverunit.Thisindicatorshallbemountedatthefrontoftheoptionalheatsinknearthebeamaperture(requiredforCDRHcompliantoperationonly).

PowerConsumption(VA) <140OperatingVoltage 88to264VAC,50/60HzAmbientTemperature OperatingConditions 10to40°C(50to104°F),non-condensing Non-OperatingCondition -30to60°C(-22to140°F)Dimensions1(LxWxH) 196X164X99.5mm(7.72x6.46x3.92in.)CableLength(HeadtoController) 2m(6.56ft.),optional5m(16.4ft.)Weight 1.85kg(4.08lbs.)

Meter FieldMax™II-TO(PartNumber:1098579)Sensor PS10Q(PartNumber:1098400)1 Pleaseconsideradditionalspaceforthefrontpanelswitchesandthecableconnectionsontherearpanel.

Airflow

A

84 mm(3.31 in.)50 mm

(1.97 in.)

Dowel pin(3 pcs)

69 m

m (2

.72

in.)

4.50

mm

(1.7

7 in

.)7

mm

(.28

in.)

19 mm(.75 in.)

80 m

m(3

.149

in.)

22.5

0 m

m(.8

9 in

.)

147 mm (5.79 in.)158 mm (6.22 in.)

135 mm (5.31 in.)

6.4

mm

(.25

in.)

16.4

mm

(.65

in.)

131

mm

(5.1

6 in

.)

0 m

m (0

in.)

8 mm (.31 in.)20 mm (.78 in.)

6 mm (.24 in.)0 mm (0 in.)

0 mm (0 in.)

70.40 mm(2.77 in.)

72 mm(2.83 in.)

170 mm (6.69 in.)180 mm (7.09 in.)

192.50 mm (7.58 in.)196.50 mm (7.74 in.)

LaserEmissionIndicator

Airflow

102.

50 m

m(4

.035

in.)

121.

9 m

m (4

.79

in.)

Beam

91Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Measurement Tools

Page 94: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

High-Power Optically Pumped Semiconductor Lasers (OPSL)

Genesis CX STM-Series

Mechanical Specifications

19.38 mm(0.76 in.)

80 mm(3.15 in.)

144.93 mm(5.71 in.)

156.06 mm(6.14 in.)

5.56 mm(0.22 in.)

280.

57 m

m(1

1.05

in.)

182.

88 m

m(7

.2 in

.)

108.

9 m

m(4

.29

in.)

34.9

3 m

m(1

.38

in.)

20.6

5 m

m(0

.81

in.)

133.

38 m

m(5

.25

in.)

0.0

mm

(0.0

in.)

47.28 mm(1.86 in.)

165.38 mm (6.51 in.)10.0 mm(0.39 in.)

4.78 mm Dia. ThruC’Bore 7.92 mm Dia.X 4.83 mm Deep(0.188 Dia. ThruC’Bore 0.312 in. Dia.X 0.19 in. Deep)(6X)

137.26 mm(5.4 in.)

280.67 mm(11.05 in.)

280.67 mm(11.05 in.)

127 mm(5.0 in.)

Power On IndicatorManual Shutter

11.94 mm(0.47 in.)

Slot 6.38 +0.03/-0.00 mm Wide X 9.7 mm Deep(0.251 +0.001/-0.00 in. Wide X 0.38 in. Deep

6.38 +0.03/-0.00 mm Dia. X 9.7 mm Deep(0.251 +0.001/-0.00 in. Dia. X 0.38 in. Deep

52.85 mm(2.08 in.)

44.75 mm(1.76 in.)

84.51 mm(3.33 in.)

156.06 mm(6.14 in.)

OutputBeam

Heatsink Surface

FanAux.Control

DC PowerGround Lug

Min. Bend Radius

159.8 mm(6.29 in.)

19.8 mm(0.78 in.)

361.1 mm(14.22 in.)

228.9 mm(9.01 in.)

127 mm(5.0 in.)

Min. Bend Radius

Laser Head – Side View

Laser Head – Top View Laser Head – Bottom View

Laser Head – Rear View

Laser Head – Front View

Features

• Extremely low noise performance

• Superior mode quality

• OPSL reliability

• Choice of air or water-cooled solutions

• Available in OEM or end user versions

• Optimum wavelengths and power for superior results - Up to 250 mW true CW (continuous wave) at 355 nm - 1W at 460 nm - Up to 2W at 480 nm - Up to 4W at 488 nm - Up to 4W at 514 nm - Up to 18W at 532 nm - Up to 3W at 577 nm

92 www.Coherent.com • [email protected] Reliability & Performance •

Page 95: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Optical Specifications2 Genesis CX 355-40/601 CX 355-80/100/150/200/2501

Wavelength(nm) 355±2FWHMLinewidth(GHz) <50PulseFormat CWSpectralPurity(%) >99OutputPower3(mW) 40,60 80,100,150,200,250SpatialMode TEM00BeamQuality(M2) <1.2BeamCircularity4 1.0±0.1BeamWaistDiameter(mm)(FW,1/e2) Horizontal 0.975±0.2 Vertical 0.915±0.2BeamDivergence(mrad)(FW,1/e2) <1.2BeamWaistLocation5(mm) ±325BeamPointingStability6(μrad/°C) <6HorizontalBeamPositionTolerance(mm) ±<1.0VerticalBeamPositionTolerance(mm) ±<1.0BeamPointingTolerance(mrad) <5PolarizationRatio Linear,>100:1PolarizationDirection Vertical,±5°Noise7(%,rms)(10Hzto1MHz) <1 <0.5PowerStability(%)(pk-pk) ±<1Warm-UpTime(minutes) <10CDRHCompliant Yes

OperatingVoltage(VAC) 100to240Frequency(Hz) 50to60PowerConsumption(W) 50010

AmbientTemperature(°C) Operating 10to40 Non-Operating -10to60RelativeHumidity8(%) 5to95CEMarking IEC61010-1/EN61010-1Dimensions(LxWxH) LaserHead9 281x156x85mm(11.06x6.14x3.35in.) Cables(laserheadtocontroller) 2m(6.5ft.)

Electrical Specifications

Environmental Conditions

1 AvailableinOEMorenduserversions.2 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.3 Thisproductisofferedinseveraloutputpowerversions:40mW,60mW,80mW,100mW,150mW,200mWand250mW.4 Circularitydefinedasverticaldiameterdividedbyhorizontaldiameter.5 Negativevaluecorrespondstoalocationinsidehead.6 Afterwarm-upover2hours.7 Validforultrapower>75mW.8 Non-condensing.9 Backconnectornotincludedinlaserheadlengthdimension.10PowerconsumptionfortheCX355-250is600W.

Genesis CX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

93Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 96: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Optical Specifications2 Genesis CX 460-10001 CX 480-1000/20001 CX 488-2000/40001

Wavelength(nm) 460±3 480±3 488±3FWHMLinewidth(GHz) <30PulseFormat CWSpectralPurity(%) >99OutputPower3(mW) 1000 1000,2000 2000,4000SpatialMode TEM00BeamQuality <1.1BeamCircularity4 1.0±0.1BeamWaistDiameter2(mm)(FW,1/e2) 2.25±10%BeamDivergence2(mrad)(FW,1/e2) <0.5BeamWaistLocation2,5(m) ±0.5BeamPointingStability6(μrad/°C) <2HorizontalBeamPositionTolerance7(mm) ±<1.0VerticalBeamPositionTolerance7(mm) ±<1.0BeamPointingTolerance7(mrad) <5PolarizationRatio Linear,>100:1PolarizationDirection Horizontal,±5°Noise(%,rms)(10Hzto10MHz) <0.1PowerStability8(%)(pk-pk) ±<1Warm-UpTime(minutes) <10CDRHCompliant Yes

OperatingVoltage(VAC) 100to240Frequency(Hz) 50to60PowerConsumption(W) 500

AmbientTemperature(°C) Operating 10to40 Non-Operating -10to60RelativeHumidity9(%) 5to95CEMarking IEC61010-1/EN61010-1Dimensions(LxWxH) LaserHead10 281x156x85mm(11.06x6.14x3.35in.) Cables(laserheadtocontroller) 2m(6.5ft.)

Electrical Specifications

Environmental Conditions

1 AvailableinOEMorenduserversions.2 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.3 Thisproductisofferedinseveraloutputpowerversionsfrom1Wto7W.Theoutputpowercanbeadjustedfrom250mWtomaximumpower.4 Circularitydefinedasverticaldiameterdividedbyhorizontaldiameter.5 Negativevaluecorrespondstoalocationinsidehead.6 After2-hourwarm-up.7 Measuredattheoutputwindow.8 Measuredover8hrs.9 Non-condensing.10Backconnectornotincludedinlaserheadlengthdimension.

PreliminaryPreliminaryPreliminary

Genesis CX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

94 www.Coherent.com • [email protected] Reliability & Performance •

Page 97: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Optical Specifications2 Genesis CX 514-2000/ CX 532-2000/4000/ CX 532-10000 40001 5000/6000/ 7000/80001

Wavelength(nm) 514±3 532±3 532±3FWHMLinewidth(GHz) <30PulseFormat CWSpectralPurity(%) >99OutputPower3(mW) 2000,4000 2000,4000,5000, 10,000 6000,7000,8000SpatialMode TEM00BeamQuality <1.1BeamCircularity4 1.0±0.1BeamWaistDiameter2(mm)(FW,1/e2) 2.25±10%BeamDivergence2(mrad)(FW,1/e2) <0.5BeamWaistLocation2,5(m) ±0.5BeamPointingStability6(μrad/°C) <2HorizontalBeamPositionTolerance7(mm) ±<1.0VerticalBeamPositionTolerance7(mm) ±<1.0BeamPointingTolerance7(mrad) <5PolarizationRatio Linear,>100:1PolarizationDirection Horizontal,±5°Noise(%,rms)(10Hzto10MHz) <0.1PowerStability8(%)(pk-pk) ±<1Warm-UpTime(minutes) <10CDRHCompliant Yes

OperatingVoltage(VAC) 100to240Frequency(Hz) 50to60PowerConsumption(W) 50011

AmbientTemperature(°C) Operating 10to40 Non-Operating -10to60RelativeHumidity9(%) 5to95CEMarking IEC61010-1/EN61010-1Dimensions(LxWxH) LaserHead10 281x156x85mm(11.06x6.14x3.35in.) Cables(laserheadtocontroller) 2m(6.5ft.)

Electrical Specifications

Environmental Conditions

1 AvailableinOEMorenduserversions.2 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.3 Thisproductisofferedinseveraloutputpowerversionsfrom1Wto7W.Theoutputpowercanbeadjustedfrom250mWtomaximumpower.4 Circularitydefinedasverticaldiameterdividedbyhorizontaldiameter.5 Negativevaluecorrespondstoalocationinsidehead.6 After2-hourwarm-up.7 Measuredattheoutputwindow.8 Measuredover8hrs.9 Non-condensing.10Backconnectornotincludedinlaserheadlengthdimension.11 PowerconsumptionfortheCX532-7000andCX532-8000is600W.PowerconsumptionfortheCX532-10000is700W.

Genesis CX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

95Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 98: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Optical Specifications2 Genesis CX 577-1000/2000/30001

Wavelength(nm) 577±3FWHMLinewidth(GHz) <30PulseFormat CWSpectralPurity(%) >99OutputPower3(mW) 1000,2000,3000SpatialMode TEM00BeamQuality <1.1BeamCircularity4 1.0±0.1BeamWaistDiameter2(mm)(FW,1/e2) 2.25±10%BeamDivergence2(mrad)(FW,1/e2) <0.5BeamWaistLocation2,5(m) ±0.5BeamPointingStability6(μrad/°C) <2HorizontalBeamPositionTolerance7(mm) ±<1.0VerticalBeamPositionTolerance7(mm) ±<1.0BeamPointingTolerance7(mrad) <5PolarizationRatio Linear,>100:1PolarizationDirection Horizontal,±5°Noise(%,rms)(10Hzto10MHz) <0.1PowerStability8(%)(pk-pk) ±<1Warm-UpTime(minutes) <10CDRHCompliant Yes

OperatingVoltage(VAC) 100to240Frequency(Hz) 50to60PowerConsumption(W) 500

AmbientTemperature(°C) Operating 10to40 Non-Operating -10to60RelativeHumidity9(%) 5to95CEMarking IEC61010-1/EN61010-1Dimensions(LxWxH) LaserHead10 281x156x85mm(11.06x6.14x3.35in.) Cables(laserheadtocontroller) 2m(6.5ft.)

Electrical Specifications

Environmental Conditions

1 AvailableinOEMorenduserversions.2 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.3 Thisproductisofferedinseveraloutputpowerversionsfrom1Wto7W.Theoutputpowercanbeadjustedfrom250mWtomaximumpower.4 Circularitydefinedasverticaldiameterdividedbyhorizontaldiameter.5 Negativevaluecorrespondstoalocationinsidehead.6 After2-hourwarm-up.7 Measuredattheoutputwindow.8 Measuredover8hrs.9 Non-condensing.10Backconnectornotincludedinlaserheadlengthdimension.

Preliminary

Genesis CX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

96 www.Coherent.com • [email protected] Reliability & Performance •

Page 99: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

52.85 mm(2.08 in.)

27.0 mm(1.06 in.)41.28 mm(1.63 in.)

147.32 mm(5.8 in.)

10.0 mm(0.39 in.)

26.97 mm(1.06 in.)

6.375 mm (0.251 in.) Dia.x 7.92 mm (0.31 in.) DeepAlignment Pin Hole

6.375 mm (0.251 in.) Widex 7.92 mm (0.31 in.) DeepAlignment Pin Slot

4.78 mm (0.188 in.) Dia.Mounting Screw Holes6 Places

Cooling Surface

2.03 mm(0.08 in.)

221.77 mm(8.73 in.)

280.57 mm(11.05 in.)

189.23 mm(7.45 in.)

139.73 mm(5.5 in.)

115.25 mm(4.54 in.)

9.53 mm (0.38 in.)

5.56 mm(0.22 in.)

52.85 mm(2.08 in.)

156.06 mm(6.14 in.)

44.75 mm(1.76 in.)

87.12 mm(3.43 in.)

ShutterPowerIndicatorLamp

Output Beam

Ground

DC Power In

Control

Genesis CX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

Mechanical Specifications

Genesis CX 532-10000

Bottom View

Front View

Side View

Top View

Rear View

97Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 100: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

208.28 mm(8.2 in.)

96.52 mm(3.8 in.)

299.72 mm(11.8 in.)

Genesis CX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

Mechanical Specifications

Genesis CX-Series High Current OEM Power Supply

Front View Rear View

Top View

Side View

Bottom View

208.28 mm(8.2 in.)

96.52 mm(3.8 in.)

299.72 mm(11.8 in.)

98 www.Coherent.com • [email protected] Reliability & Performance •

Page 101: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Genesis CX-Series lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Genesis CX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

Genesis CX-Series Benchtop Power Supply

Mechanical Specifications

159.8 mm(6.29 in.)

19.8 mm(0.78 in.)

361.1 mm(14.22 in.)

228.9 mm(9.01 in.)

Side ViewFront View

Genesis CX 532-12000/15000/18000 Benchtop Power Supply

191 mm(7.5 in.)

170 mm(6.7 in.)

478 mm(18.83 in.)

58 mm(2.3 in.)

409 mm(16.1 in.)

236 mm(9.3 in.)

150 mm(5.9 in.)

Top View

Front View Side View Rear View

99Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 102: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

High-Power Optically Pumped Semiconductor Lasers (OPSL)

Genesis CX 355 STM Compact (OEM)

Features

• Extremely low noise performance

• Superior mode quality

• OPSL reliability

• Includes air-cooled heatsink

• Available in an OEM configuration only

• New reduced size OEM 355 nm up to 100 mW

Mechanical Specifications

287.32 mm(11.31 in.)

138.33 mm(5.446 in.)

OUTPUT BEAM

95.38 mm(3.755 in.)

20.96 mm(0.825 in.)110.74 mm

(4.36 in.)

234.19 mm(9.22 in.)

50.75 mm(2.0 in.)

7.95 mm(0.31 in.)

31.75 mm(1.25 in.)

9.53 mm(0.375 in.)

30.15 mm(1.19 in.)

204.

77 m

m(8

.06

in.)

188.

57 m

m(7

.42

in.)

68.5

8 m

m(2

.70

in.)

52.3

7 m

m(2

.06

in.)

127.

0 m

m(5

.0 in

.)

21.1

6 m

m(0

.833

in.)

204.

77 m

m(8

.06

in.)

188.

57 m

m(7

.42

in.)

269.

85 m

m(1

0.62

in.)

260.

78 m

m(1

0.27

in.)

68.5

8 m

m(2

.70

in.)

52.3

7 m

m(2

.06

in.)

24V IN

RS232D SERIAL PORT

INTERLOCKUSB 1

0

42.16 mm(1.66 in.)

111.76 mm(4.40 in.)

111.76 mm(4.40 in.)

111.0 mm(4.37 in.)

16.0 mm(0.63 in.)

111.0 mm(4.37 in.)

77.65 mm(3.06 in.)

18.34 mm(0.72 in.)

0

MOUNTING HOLES AREBOTH NEAR AND FARSIDE

0

0

GND

DIODE OUTUSB 2

0

.600 .630

015.24 mm(0.60 in.)

0

MOUNTING HOLES (BOTTOM)

6-32 6-32M3 M3

6-326-32

6-32

6-32

M3 M3

M3

M3

6-32

Side View

Top View

Rear View Front View

100 www.Coherent.com • [email protected] Reliability & Performance •

Page 103: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Genesis CX 355-40/60 CX 355-80/100Wavelength(nm) 355±2FWHMLinewidth(GHz) <50PulseFormat CWSpectralPurity(%) >99OutputPower2(mW) 40,60 80,100SpatialMode TEM00BeamQuality(M2) <1.2BeamCircularity3 1.0±0.1BeamWaistDiameter(mm)(FW,1/e2) Horizontal 0.975±0.2 Vertical 0.915±0.2BeamDivergence(mrad)(FW,1/e2) <1.2BeamWaistLocation4(mm) ±325BeamPointingStability5(μrad/°C) <6HorizontalBeamPositionTolerance(mm) ±<1.0VerticalBeamPositionTolerance(mm) ±<1.0BeamPointingTolerance(mrad) <5PolarizationRatio Linear,>100:1PolarizationDirection Horizontal,±5°Noise6(%,rms)(10Hzto1MHz) <1 <0.5PowerStability(%)(pk-pk) ±<1Warm-UpTime(minutes) <10CDRHCompliant Yes

OperatingVoltage(VAC) 100to240Frequency(Hz) 50to60PowerConsumption(W) 500

AmbientTemperature(°C) Operating 10to40 Non-Operating -10to60RelativeHumidity7(%) 5to95CEMarking IEC61010-1/EN61010-1Dimensions(LxWxH) LaserHead8 250.1x138.0x50.8mm(9.84x5.4x2.0in.) Cables(laserheadtocontroller) 2m(6.5ft.)1 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.2 Thisproductisofferedinseveraloutputpowerversions:40mW,60mW,80mW,100mW,150mW,200mWand250mW.3 Circularitydefinedasverticaldiameterdividedbyhorizontaldiameter.4 Negativevaluecorrespondstoalocationinsidehead.5 Afterwarm-upover2hours.6 Validforultrapower>75mW.7 Non-condensing.8 Backconnectornotincludedinlaserheadlengthdimension.

Genesis CX 355 STM Compact (OEM)High-Power Optically Pumped Semiconductor Lasers (OPSL)

Optical Specifications1

Electrical Specifications

Environmental Conditions

101Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 104: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Genesis CX 355 STM Compact (OEM)High-Power Optically Pumped Semiconductor Lasers (OPSL)

287.32 mm(11.31 in.)

138.33 mm(5.446 in.)

OUTPUT BEAM

95.38 mm(3.755 in.)

20.96 mm(0.825 in.)110.74 mm

(4.36 in.)

234.19 mm(9.22 in.)

50.75 mm(2.0 in.)

7.95 mm(0.31 in.)

31.75 mm(1.25 in.)

9.53 mm(0.375 in.)

30.15 mm(1.19 in.)

204.

77 m

m(8

.06

in.)

188.

57 m

m(7

.42

in.)

68.5

8 m

m(2

.70

in.)

52.3

7 m

m(2

.06

in.)

127.

0 m

m(5

.0 in

.)

21.1

6 m

m(0

.833

in.)

204.

77 m

m(8

.06

in.)

188.

57 m

m(7

.42

in.)

269.

85 m

m(1

0.62

in.)

260.

78 m

m(1

0.27

in.)

68.5

8 m

m(2

.70

in.)

52.3

7 m

m(2

.06

in.)

24V IN

RS232D SERIAL PORT

INTERLOCKUSB 1

0

42.16 mm(1.66 in.)

111.76 mm(4.40 in.)

111.76 mm(4.40 in.)

111.0 mm(4.37 in.)

16.0 mm(0.63 in.)

111.0 mm(4.37 in.)

77.65 mm(3.06 in.)

18.34 mm(0.72 in.)

0

MOUNTING HOLES AREBOTH NEAR AND FARSIDE

0

0

GND

DIODE OUTUSB 2

0

.600 .630

015.24 mm(0.60 in.)

0

MOUNTING HOLES (BOTTOM)

6-32 6-32M3 M3

6-326-32

6-32

6-32

M3 M3

M3

M3

6-32

Mechanical Specifications

Genesis CX-Series Controller

Front View

Rear View

Side View

Top View

102 www.Coherent.com • [email protected] Reliability & Performance •

Page 105: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Genesis CX-Series lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Genesis CX 355 STM Compact (OEM)High-Power Optically Pumped Semiconductor Lasers (OPSL)

Mechanical Specifications

Genesis CX-Series Optional AC/DC Power Supply

2-M4

4-M4Mounting Hole

Name plateCN1

Output voltageadjustable potentiometer

LED

Terminal cover

CN2CN3

Name plateM4

M4

Output terminal(+ )

Output terminal(- )

AC(N)AC(L)

AIR FLOW

xam607150

.510

242

(14)

(15.5)

8.6

(23.

5)

25max

(87)

(30)28.5 64±0.5

(6)

107

(50)

12

1220

±0.5

54 74±0.5

(75)

12

FG( )

Mounting Hole(Bottom sides)

HV.AD

J

Top View

Rear View

Side View

Front View

Bottom View

103Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 106: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Genesis MX STM-Series (OEM)High-Power Optically Pumped Semiconductor Lasers (OPSL)

Mechanical Specifications

Slot3.2 +0.025/-0.0 mm (0.126 + 0.001/-0.0 in.) WideX 2.03 mm (0.08 in.) Long X 5.08 mm (0.20 in.) Deep

Mounting HolesM3 X 12.2 mm(0.48 in.) Deep(4X)

3.2 +0.025/-0.0 mm (0.126 + 0.001/-0.0 in.) DIAX 5.08 mm (0.20 in.) Deep

5.46 mm(0.22 in.)

120.65 mm(4.75 in.)

111.1 mm(4.37 in.)

34.55 mm (1.36 in.)

4.78 mm (0.19 in.)

61 mm(2.4 in.) 34 mm

(1.34 in.)

17 mm(0.67 in.)

22 mm(0.87 in.)

44 mm(1.73 in.)

26 mm(1.02 in.)

29.78 mm(1.17 in.)

28.15 mm(1.11 in.)

18.8 mm(0.74 in.)

18.8 mm(0.74 in.) 24.89 mm

(0.98 in.)

6.1 mm(0.24 in.) 5.08 mm

(0.2 in.)

45.21 mm(1.78 in.)

6.35 mm(0.25 in.)

6.35 mm(0.25 in.)

6.35 mm(0.25 in.)

5.08 mm(0.2 in.)

16.26 mm(0.64 in.)Spacer Detail

Clamping Bar Detail

3.175 mm(0.125 in.)

1.52 mm (0.06 in.)12.95 mm (0.51 in.)

4.06 mm (0.16 in.)

86.87 mm (3.42 in.)89.92 mm (3.54 in.)112.78 mm (4.44 in.)

112.78 mm (4.44 in.)120.65 mm (4.75 in.)

11.43 mm (0.45 in.)

53.59 mm(2.11 in.)

12.7 mm (0.5 in.)

15.24 mm (0.6 in.)

8-32 UNC-2B X 0.50 Deep(4X)

0.125 Dia. Dowel Pin (2X)

0.188 Dia. Thru (2X)

This surface must be flat within 0.001 in.and have 32 µm finish or better withinTEC mounting areas.

Base Plate Requirements

Front View

Top View

Rear View

Laser Head

Side View

Features

• OEM laser head designed for easy integration

• OPSL reliability

• Compact, efficient design

• Optimum wavelengths and power for superior results - 500mW at 460 nm - 500mW at 480 nm - 500mW and 1W at 488 nm - 500mW and 1W at 514 nm - 500mW and 1W at 532 nm - 500mW at 561 nm

- 500mW and 1W at 577 nm - 500mW at 590 nm

104 www.Coherent.com • [email protected] Reliability & Performance •

Page 107: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Optical Specifications1

Utility and Environmental Requirements

Genesis MX STM-Series (OEM)High-Power Optically Pumped Semiconductor Lasers (OPSL)

Genesis MX 460-500 MX 480-500 MX 488-500/ MX 514-500/ 1000 1000Wavelength(nm) 460±3 480±3 488±3 514±3OutputPower(mW) 500 500 500,1000 500,1000SpatialMode TEM00FWHMLinewidth(GHz) <30PulseFormat CWBeamCircularity 1.0±0.1BeamPositionTolerance(mm) Horizontal ±<1.0 Vertical ±<1.0BeamWaistDiameter2(mm)(FW,1/e2) 1.0±0.1BeamDivergence2(mrad)(FW,1/e2) 0.7±0.1BeamWaistLocation2,8,9(m) ±0.25M2

Horizontal <1.1 Vertical <1.1PointingStability4(μrad/°C) <5Noise 10Hzto10MHz2(%,rms) <0.1 10Hzto5kHz(%,peak-to-peak) <17

PolarizationRatio Horizontal,>100:1CDRHCompliance NoWarm-UpTime(minutes) <10DirectModulation5 Available

OperatingDiodeCurrent(A) <10 <10 <10,<12 <10MaximumDiodeCurrent(A) <12 <12 <12,<15 <12DiodeVoltage(V) 1.5to2.2CoolingRequirements6 ActivecoolingrequiredCaseTemperature(°C) 25±2Humidity Non-condensingDimensions(LxWxH) LaserHead 121x44x65mm(4.76x1.73x2.56in.)Weight LaserHead(g) 730±101 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.2 Typicalvalue.3 Measuredfromtheoutputface,negativevaluecorrespondstoalocationinsidethehead;positiveoutside.4 Measuredattheoutputwindow:tolerancerelativetothenominalcenteroftheoutputwindowandperpendiculartothemountingplane.5 Theoreticallimitis>1MHz;actualperformancewillbelimitedbythediode-driver(notincluded).6 Contactintegrationsupportforoptionsonair-coolingTECorwaterplate.7 Over8hours.8 Measuredattheoutputofthelaserhead.9 Negativevaluecorrespondstoalocationwithinthehead.

Preliminary Preliminary Preliminary Preliminary

105Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 108: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Genesis MX 532-500/ MX 561-500 MX 577-500/ MX 590-500 1000 1000Wavelength(nm) 532±3 561±3 577±3 590±3OutputPower(mW) 500,1000 500 500,1000 500SpatialMode TEM00FWHMLinewidth(GHz) <30PulseFormat CWBeamCircularity 1.0±0.1BeamPositionTolerance(mm) Horizontal ±<1.0 Vertical ±<1.0BeamWaistDiameter2(mm)(FW,1/e2) 1.0±0.1BeamDivergence2(mrad)(FW,1/e2) 0.7±0.1BeamWaistLocation2,8,9(m) ±0.25M2

Horizontal <1.1 Vertical <1.1PointingStability4(μrad/°C) <5Noise 10Hzto10MHz2(%,rms) <0.1 10Hzto5kHz(%,peak-to-peak) <17

PolarizationRatio Horizontal,>100:1CDRHCompliance NoWarm-UpTime(minutes) <10DirectModulation5 Available

OperatingDiodeCurrent(A) <10MaximumDiodeCurrent(A) <12DiodeVoltage(V) 1.5to2.2CoolingRequirements6 ActivecoolingrequiredCaseTemperature(°C) 25±2Humidity Non-condensingDimensions(LxWxH) LaserHead 121x44x65mm(4.76x1.73x2.56in.)Weight LaserHead(g) 730±101 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.2 Typicalvalue.3 Measuredfromtheoutputface,negativevaluecorrespondstoalocationinsidethehead;positiveoutside.4 Measuredattheoutputwindow:tolerancerelativetothenominalcenteroftheoutputwindowandperpendiculartothemountingplane.5 Theoreticallimitis>1MHz;actualperformancewillbelimitedbythediode-driver(notincluded).6 Contactintegrationsupportforoptionsonair-coolingTECorwaterplate.7 Over8hours.8 Measuredattheoutputofthelaserhead.9 Negativevaluecorrespondstoalocationwithinthehead.

Genesis MX STM-Series (OEM)High-Power Optically Pumped Semiconductor Lasers (OPSL)

Optical Specifications1

Utility and Environmental Requirements

Preliminary Preliminary Preliminary

106 www.Coherent.com • [email protected] Reliability & Performance •

Page 109: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Genesis MX STM-Series (OEM)High-Power Optically Pumped Semiconductor Lasers (OPSL)

Mechanical Specifications

Genesis MX-Series Low Current OEM Controller

16.0 mm (0.63 in.) 16.0 mm (0.63 in.)

15.24 mm (0.6 in.)

127 mm (5.0 in.)

22.43 mm (0.88 in.)

18.34 mm (0.72 in.)

77.65 mm (3.06 in.)

42.15 mm (1.66 in.)

111.76 mm (4.4 in.)

111.0 mm (4.37 in.)

15.24 mm (0.60 in.)

M3 6-32

6-32

6-32

6-32M3

M3

M3

M3

6-32 6-32

6-32

M3M3

M3

0 mm (0.0 in.)

RS-232DSerial Port

USB

Interlock

24V In

127 mm (5.0 in.)

257.

15 m

m(1

0.12

in.)

0 m

m(0

.0 in

.)0

mm

(0.0

in.)

52.3

7 m

m(2

.06

in.)

68.5

8 m

m(2

.70

in.)

243.

31 m

m(9

.58

in.)

204.

77 m

m(8

.06

in.)

188.

57 m

m(7

.42

in.)

52.3

7 m

m(2

.06

in.)

68.5

8 m

m(2

.70

in.)

204.

77 m

m(8

.06

in.)

188.

57 m

m(7

.42

in.)

111 mm (4.37 in.)

111.76 mm (4.40 in.)

Mounting Holes10X On BottomAs Indicated

Mounting Holes (both sides)

GND

Diode Out

Laser Control

TEC Ext. Fan

Front View

Rear View

Top View

Side View

Bottom View

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Genesis MX-Series lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

107Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 110: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Genesis MX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

Mechanical Specifications

78.74 mm(3.1 in.)

61.6 mm(2.43 in.)

200.86 mm(7.91 in.)

219.91 mm(8.66 in.)

21.29 mm(0.84 in.)

13.53 mm(0.53 in.)

10.41 mm(0.41 in.)

10.0 mm(0.39 in.)

0.0

mm

(0.0

in.)

36.9

6 m

m(1

.45

in.)

53.9

6 m

m(2

.12

in.)

165.

96 m

m(6

.53

in.)

182.

96 m

m(7

.20

in.)

Mounting HolesM5 - 0.8 X 0.38 in. Deep(4X)

Mounting Holes10-32 X 0.38 in. Deep(4X)

Alignment Slot0.251/0.252 in. WideX 0.25 in. LongX 0.38 in. Deep

Alignment Hole0.251/0.252 in. Dia.X 0.38 in. Deep

61.6 mm(2.43 in.)

55.0 mm(2.17 in.)

45.0 mm(1.77 in.)

M5

M5

M5

M5

10-32

10-32

10-32

10-32

68.2 mm(2.69 in.)

47.64 mm(1.88 in.)

89.22 mm(3.51 in.)

Front View

Top View

Side View

Rear View

MX-Series STM Water-cooled version

Features

• End user, turn key solution

• OPSL reliability

• Compact, efficient design

• Choice of air or water-cooled solutions

• Optimum wavelengths and power for superior results - 500mW at 460 nm - 500mW at 480 nm - 500mW and 1W at 488 nm - 500mW and 1W at 514 nm

- 500mW and 1W at 532 nm - 500mW at 561 nm - 500mW and 1W at 577 nm - 500mW at 590 nm

108 www.Coherent.com • [email protected] Reliability & Performance •

Page 111: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Optical Specifications1

Genesis MX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

Genesis MX 460-500 MX 480-500 MX 488-500/ MX 514-500/ 1000 1000Wavelength(nm) 460±3 480±3 488±3 514±3FWHMLinewidth(GHz) <30PulseFormat CWSpectralPurity(%) >99OutputPower(mW) 500 500 500,1000 500,1000SpatialMode TEM00BeamQuality(M2) <1.1BeamCircularity2 1.0±0.1BeamWaistDiameter1(mm)(FW,1/e2) 1.0±0.1BeamDivergence1(mrad)(FW,1/e2) 0.7±0.1BeamWaistLocation1,3(m) ±0.25BeamPointingStability4,5(μrad/°C) <5HorizontalBeamPositionTolerance5(mm) ±<1.0VerticalBeamPositionTolerance5(mm) ±<1.0BeamPointingTolerance5(mrad) <5PolarizationRatio Linear,>100:1PolarizationDirection Vertical,±5°Noise(%,rms)(10Hzto10MHz) <0.1PowerStability6(%)(pk-pk) ±<1Warm-UpTime(minutes) <10CDRHCompliant Yes

OperatingVoltage(VAC) 100to240Frequency(Hz) 50to60PowerConsumption(W) 500

AmbientTemperature(°C) Operating 10to40 Non-Operating -10to60RelativeHumidity7(%) 5to95CEMarking IEC61010-1/EN61010-1Dimensions(LxWxH) LaserHead8 281x156x85mm(11.06x6.14x3.35in.) Cables(laserheadtocontroller) 2m(6.5ft.)1 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.2 Circularitydefinedasverticaldiameterdividedbyhorizontaldiameter.3 Negativevaluecorrespondstoalocationinsidehead.4 After2-hourwarm-up.5 Measuredattheoutputwindow.6 Measuredover8hrs.7 Non-condensing.8 Backconnectornotincludedinlaserheadlengthdimension.

Preliminary Preliminary Preliminary Preliminary

Electrical Specifications

Environmental Conditions

109Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 112: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Genesis MX 532-500/ MX 561-500 MX 577-500/ MX 590-500 1000 1000Wavelength(nm) 532±3 561±3 577±3 590±3FWHMLinewidth(GHz) <30PulseFormat CWSpectralPurity(%) >99OutputPower2(W) 500,1000 500 500,1000 500SpatialMode TEM00BeamQuality <1.1BeamCircularity4 1.0±0.1BeamWaistDiameter1(mm)(FW,1/e2) 1.0±0.1BeamDivergence1(mrad)(FW,1/e2) 0.7±0.1BeamWaistLocation1,3(m) ±0.25BeamPointingStability2,5(μrad/°C) <5HorizontalBeamPositionTolerance5(mm) ±<1.0VerticalBeamPositionTolerance5(mm) ±<1.0BeamPointingTolerance5(mrad) <5PolarizationRatio Linear,>100:1PolarizationDirection Horizontal,±5°Noise(%,rms)(10Hzto10MHz) <0.1PowerStability6(%)(pk-pk) ±<1Warm-UpTime(minutes) <10CDRHCompliant Yes

OperatingVoltage(VAC) 100to240Frequency(Hz) 50to60PowerConsumption(W) 500

AmbientTemperature(°C) Operating 10to40 Non-Operating -10to60RelativeHumidity7(%) 5to95CEMarking IEC61010-1/EN61010-1Dimensions(LxWxH) LaserHead8 281x156x85mm(11.06x6.14x3.35in.) Cables(laserheadtocontroller) 2m(6.5ft.)1 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.2 Circularitydefinedasverticaldiameterdividedbyhorizontaldiameter.3 Negativevaluecorrespondstoalocationinsidehead.4 After2-hourwarm-up.5 Measuredattheoutputwindow.6 Measuredover8hrs.7 Non-condensing.8 Backconnectornotincludedinlaserheadlengthdimension.

Genesis MX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

Optical Specifications1Preliminary Preliminary Preliminary

Electrical Specifications

Environmental Conditions

110 www.Coherent.com • [email protected] Reliability & Performance •

Page 113: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Genesis MX STM-SeriesHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

78.74 mm(3.1 in.)

200.86 mm(7.91 in.)

219.91 mm(8.66 in.)

67.26 mm(2.65 in.)

61.6 mm(2.43 in.)

13.53 mm(0.53 in.)

10.41 mm(0.41 in.)

10.0 mm(0.39 in.)

0.0

mm

(0.0

in.)

36.9

6 m

m(1

.45

in.)

53.9

6 m

m(2

.12

in.)

165.

96 m

m(6

.53

in.)

182.

96 m

m(7

.20

in.)

Mounting HolesM5 - 0.8 X 0.38 in. Deep(4X)

Mounting Holes10-32 X 0.38 in. Deep(4X)

Alignment Slot0.251/0.252 in. WideX 0.25 in. LongX 0.38 in. Deep

Alignment Hole0.251/0.252 in. Dia.X 0.38 in. Deep

61.6 mm(2.43 in.)

55.0 mm(2.17 in.)

45.0 mm(1.77 in.)

M5

M5

M5

M5

10-32

10-32

10-32

10-32

68.2 mm(2.69 in.)

47.64 mm(1.88 in.)

89.22 mm(3.51 in.)

Genesis MX-Series Benchtop Power Supply

159.8 mm(6.29 in.)

19.8 mm(0.78 in.)

361.1 mm(14.22 in.)

228.9 mm(9.01 in.)

Side ViewFront View

Mechanical Specifications

Front View

Top View

Side View

Rear View

MX-Series STM Air-cooled version

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Genesis MX-Series lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

111Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 114: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

High-Power Optically Pumped Semiconductor Lasers (OPSL)

Genesis MX 607/639STM (OEM)

Features

• OPSL reliability

• Compact, efficient design

• Modulation rate to >50 kHz

• Ability to deliver high output powers at unique wavelengths - 500 mW at 607 nm - 1W at 639 nm

• Low heat load for ease of integration

5.46 mm(0.22 in.)

18.8 mm(0.74 in.)

18.8 mm(0.74 in.) 24.89 mm

(0.98 in.)

6.1 mm(0.24 in.) 5.08 mm

(0.2 in.)

45.21 mm(1.78 in.)

6.35 mm(0.25 in.)

6.35 mm(0.25 in.)

6.35 mm(0.25 in.)

5.08 mm(0.2 in.)

16.26 mm(0.64 in.)Spacer Detail

Clamping Bar Detail

3.175 mm(0.125 in.)

1.52 mm (0.06 in.)12.95 mm (0.51 in.)

4.06 mm (0.16 in.)

86.87 mm (3.42 in.)89.92 mm (3.54 in.)112.78 mm (4.44 in.)

112.78 mm (4.44 in.)120.65 mm (4.75 in.)

11.43 mm (0.45 in.)

53.59 mm(2.11 in.)

212.55 mm(8.37 in.)

255.68 mm(10.07 in.)

70.17 mm(2.76 in.)

13.49 mm(0.531 in.)

48.43 mm(1.91 in.)

50.27 mm(1.98 in.)

19.05 mm(0.75 in.)

9.53 mm(0.375 in.)

9.53 mm (0.375 in.)

19.05 mm(0.75 in.)

48.43 mm(1.91 in.)

13.51 mm (0.532 in.)

DC Power InLaser Output Beam

12.7 mm (0.5 in.)

15.24 mm (0.6 in.)

8-32 UNC-2B X 0.50 Deep(4X)

0.125 Dia. Dowel Pin (2X)

0.188 Dia. Thru (2X)

This surface must be flat within 0.001 in.and have 32 µm finish or better withinTEC mounting areas.

Mechanical Specifications

Base Plate Requirements

Front View

Side View

Rear View

Top View

Bottom View

112 www.Coherent.com • [email protected] Reliability & Performance •

Page 115: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Genesis MX 607-500 MX 639-1000Wavelength(nm) 607±1 639.5±1OutputPower(mW) 500 1000SpatialMode TEM00Bandwidth(nm) <0.5CollimatedVersion BeamWaistDiameter2(1/e2,mm) 1.0 BeamDivergence2(1/e2,mrad) 1.5 BeamWaistLocation2(m) 0.25M2

Horizontal <1.2 Vertical <1.2PointingStability3(μrad/°C) <10Noise 10Hzto10MHz2(%,rms) <5 10Hzto100kHz(%,peak-to-peak) <1PolarizationRatio Vertical,>100:1DirectModulation4 Available

OperatingDiodeCurrent(A) <27MaximumDiodeCurrent(A) <32DiodeVoltage(V) 1.5to2.2CoolingRequirements5 ActivecoolingrequiredCaseTemperature(°C) 25±2Humidity Non-condensingDimensions(LxWxH) LaserHead6 296x49x71mm(11.64x1.91x2.76in.)Weight LaserHead(g) 900±10

Genesis MX 607/639 STM (OEM)High-Power Optically Pumped Semiconductor Lasers (OPSL)

Optical Specifications1

Utility and Environmental Requirements

1 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.2 Typicalvalue.3 Measuredattheoutputwindow:tolerancerelativetothenominalcenteroftheoutputwindowandperpendiculartothemountingplane.4 Theoreticallimitis>1MHz;actualperformancewillbelimitedbythediode-driver(notincluded).5 Aircoolingavailablewithappropriateheatsinkandfans.6 Includescollimator.

Preliminary Preliminary

113Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 116: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

High-Power Optically Pumped Semiconductor Lasers (OPSL)

119.08 mm(4.69 in.)

62.54 mm(2.46 in.)

360.02 mm(14.17 in.)

379.07 mm(14.92 in.)

13.53 mm(0.53 in.) 10.41 mm

(0.41 in.)

10.0 mm(0.39 in.)

173.

51 m

m(6

.83

in.)

0.0

mm

(0.0

in.)

190.

51 m

m(7

.5 in

.)

302.

51 m

m(1

1.91

in.)

319.

51 m

m(1

2.58

in.)

Mounting HolesM5 - 0.8 X 0.38 in. Deep(4X)

Mounting Holes10-32 X 0.38 in. Deep(4X)

Alignment Slot0.251/0.252 in. WideX 0.25 in. LongX 0.38 in. Deep

Alignment Hole0.251/0.252 in. Dia.X 0.38 in. Deep

61.6 mm(2.43 in.)

65.0 mm(2.56 in.)62.54 mm

(2.46 in.)

21.29 mm(0.84 in.)

45.0 mm(1.77 in.)

131.85 mm(5.19 in.)

180.58 mm(7.11 in.)

M5

M5

M5

M5

10-32

10-32

10-32

10-32

68.2 mm(2.69 in.)

47.64 mm(1.88 in.)

95.25 mm(3.75 in.)

Genesis MX 607/639 STM

Features

• End user, turn key solution

• OPSL reliability

• Compact, efficient design

• Optimum wavelengths and power for superior results - 500mW at 607 nm - 1W at 639 nm

• Choice of air or water-cooled solutions

Mechanical Specifications

Front View

Side View

Rear View

MX-Series STM Water-cooled version

114 www.Coherent.com • [email protected] Reliability & Performance •

Page 117: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Genesis MX 607-500 MX 639-1000Wavelength(nm) 607±3 639±3Bandwidth(nm) <0.5PulseFormat CWSpectralPurity(%) >99OutputPower(W) 500 1000SpatialMode TEM00BeamQuality(M2) <1.2BeamCircularity2,3,5 1.1±0.1BeamWaistDiameter1,2(mm)(FW,1/e2) 1.0±0.2BeamDivergence1,2(mrad)(FW,1/e2) <1.5BeamWaistLocation2,4(m) 0.25±0.5BeamPointingStability6(μrad/°C) <10HorizontalBeamPositionTolerance6(mm) ±<1.0VerticalBeamPositionTolerance6(mm) ±<1.0BeamPointingTolerance6(mrad) <10PolarizationRatio Linear,>100:1PolarizationDirection Horizontal,±5°Noise RMS(%)(10Hzto10MHz)10 <5 RMS(%)(10Hzto100kHz)10 <1PowerStability7(%)(pk-pk) ±<1Warm-UpTime(minutes) <10CDRHCompliant Yes

OperatingVoltage(VAC) 100to240Frequency(Hz) 50to60PowerConsumption(W) 500

AmbientTemperature(°C) Operating 10to40 Non-Operating -10to60RelativeHumidity8(%) 5to95CEMarking IEC61010-1/EN61010-1Dimensions(LxWxH) LaserHead9 360x120x96mm(14.17x4.69x3.75in.) Cables(laserheadtocontroller) 2m(6.5ft.)

Genesis MX 607/639 STMHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

Optical Specifications1

1 Opticalparametersmeasuredattheoutputplaneofthelaserhead.Unlessnotedallparametersvalidforthelifetimeoftheunit.2 Typicalvalue.3 Circularitydefinedasverticaldiameterdividedbyhorizontaldiameter.4 Negativevaluecorrespondstoalocationinsidehead.5 After2-hourwarm-up.6 Measuredattheoutputwindow.7 Measuredover8hrs.8 Non-condensing.9 Backconnectornotincludedinlaserheadlengthdimension.10Atratedpower.

Preliminary Preliminary

Electrical Specifications

Environmental Conditions

115Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 118: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

119.08 mm(4.69 in.)

62.54 mm(2.46 in.)67.34 mm

(2.65 in.)

360.02 mm(14.17 in.)

379.07 mm(14.92 in.)

13.53 mm(0.53 in.) 10.41 mm

(0.41 in.)

10.0 mm(0.39 in.)

173.

51 m

m(6

.83

in.)

0.0

mm

(0.0

in.)

190.

51 m

m(7

.5 in

.)

302.

51 m

m(1

1.91

in.)

319.

51 m

m(1

2.58

in.)

Mounting HolesM5 - 0.8 X 0.38 in. Deep(4X)

Mounting Holes10-32 X 0.38 in. Deep(4X)

Alignment Slot0.251/0.252 in. WideX 0.25 in. LongX 0.38 in. Deep

Alignment Hole0.251/0.252 in. Dia.X 0.38 in. Deep

61.6 mm(2.43 in.)

65.0 mm(2.56 in.)62.54 mm

(2.46 in.)

67.34 mm(2.65 in.)

45.0 mm(1.77 in.)

195.96 mm(7.72 in.)

147.61 mm(5.81 in.)

M5

M5

M5

M5

10-32

10-32

10-32

10-32

68.2 mm(2.69 in.)

47.64 mm(1.88 in.)

95.25 mm(3.75 in.)

Front View

Side View

Top View

Rear View

Genesis MX 607/639 STMHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

Mechanical Specifications

MX-Series STM Air-cooled version

116 www.Coherent.com • [email protected] Reliability & Performance •

Page 119: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Genesis CX-Series lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Genesis MX 607/639 STMHigh-Power Optically Pumped Semiconductor Lasers (OPSL)

Genesis CX-Series Benchtop Power Supply

Mechanical Specifications

159.8 mm(6.29 in.)

19.8 mm(0.78 in.)

361.1 mm(14.22 in.)

228.9 mm(9.01 in.)

Side ViewFront View

117Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 120: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Chameleon DiscoveryDual Output, Broadly Tunable Laser for Multiphoton Imaging

Features

• Automated hands free operation

• High average and high peak power for excellent fluorescent yield and efficiency

• GDD dispersion compensated output for optimized peak power at the sample plane

• Secondary output standard with high average power for multiwavelength imaging and optogenetics photoactivation

• Synchronized output pulse trains for CARS/SRS and wavelength mixing

• Industrial design for high uptime and reliability

Mechanical Specifications

118 www.Coherent.com • [email protected] Reliability & Performance •

120.8 mm(4.76 in.)

286.7 mm(11.29 in.)

445.2 mm(17.53 in.)

820.8 mm (32.31 in.)

259.9 mm (10.23 in.)

329.3 mm (12.96 in.)

Top View

Side View

Front View

Page 121: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Chameleon DiscoveryDual Output, Broadly Tunable Laser for Multiphoton Imaging

Chameleon Discovery Optical Output ATuningRange(nm) 680to1300AverageOutputPower(mW) 700nm 1300 800nm 1400 900nm 1300 1000nm 1100 1200nm 800 1300nm 600PulseDuration1,2(fs) 100RepetitionRate(MHz) 80±0.5BeamMode1 M2<1.2BeamDiameter1(mm) 1.2±0.2Ellipticity1 0.9to1.1Astigmatism1(%) <10Polarization1 Horizontal,>500:1Noise1,3(%) <0.5PowerStability4(%) ±1TuningSpeed5(nm/s) >50PointingAccuracy(μrad)6 <350DispersionCompensationRange(fs2) 680nm 0to45,000 800nm 0to25,000 1050nm 0to10,000 1300nm 0to8000Optical Output BWavelength(nm) 1040AverageOutputPower(mW) >1500PulseDuration2(fs) 160RepetitionRate7(MHz) 80±0.5BeamMode M2<1.2BeamDiameter(mm) 1.2±0.2Ellipticity 0.8to1.2Astigmatism(%) <10Polarization Horizontal,>500:1Noise3(%) <0.25PowerStability4(%) ±1

System Specifications

119Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

1 At900nm.2 Assumessech2pulseshape.3 RMS,10Hzto10MHz.4 Powerdriftina2hourperiodafter1hourwarm-upand±1°Cambienttemperaturechange.5 Averagedoverentiretuningrange.6 MaximumdeviationoverentireGDDdispersionadjustmentandwavelengthrange.7 PhaselockedtoOutputA.

Page 122: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

120 www.Coherent.com • [email protected] Reliability & Performance •

Chameleon DiscoveryDual Output, Broadly Tunable Laser for Multiphoton Imaging

Chameleon Discovery

OperatingVoltage(VAC) 90to250(autoranging)MaximumOperatingCurrent(A) PowerSupply <8at90VAC Chiller <14at90VAC MRU <2at90VACSystemPowerConsumption(W) 2300LineFrequency(Hz) 47to63Communications/ControlInterfaces1 RS-232,USB,Ethernet(option)

OperatingTemperatureRange 15to35°C(59to95°F)StorageTemperatureRange 0to40°C(32to104°F)Humidity Non-condensingAltitude(m) <2000

Dimensions PowerSupply 19”unit,3U Chiller 19”unit,3U MRU 19”unit,2U1 PCrequired.

Utility Requirements

Environmental Requirements

Mechanical Specifications

Page 123: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Chameleon DiscoveryDual Output, Broadly Tunable Laser for Multiphoton Imaging

121Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Chameleon systems. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Chameleon Discovery Laser Power (typical)

Chameleon Discovery Pulse Duration (typical)

Puls

e D

urat

ion

(fs)

0

20

40

60

80

100

120

140

650

Wavelength (nm)750 850 950 1050 1150 1250 1350

Lase

r Pow

er (m

W)

0

500

1000

1500

2000

2500

650

Wavelength (nm)750 850 950 1050 1150 1250 1350

Page 124: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Chameleon

Chameleon

369.0 mm (14.53 in.)

133.7 mm (5.26 in.)

530.0 mm (20.87 in.)

530.0 mm (20.87 in.)

326.2 mm(12.84 in.)369.0 mm(14.53 in.)

30.0 mm (1.18 in.)

50.5 mm (1.99 in.)

610.4 mm (24.03 in.)41.0 mm (1.61 in.)

189.

2 m

m(7

.45

in.)

104.6 mm(4.12 in.)

165.

6 m

m(6

.52

in.)

189.

2 m

m(7

.45

in.)

189.

2 m

m(7

.45

in.)

120.

9 m

m(4

.76

in.)

326.

2 m

m (1

2.84

in.)

369.

0 m

m (1

4.53

in.)

output

output

output

Min. Bend Radius152.0 mm (6.00 in.)

Chameleon Ultra FamilyWidely Tunable, Hands-Free, Modelocked Ti:Sapphire Lasers

Features

• Hands-free operation

• Sealed maintenance-free design

• Ultrawide tuning range (up to 400 nm)

• High output power (up to >3.5W)

• High peak power (>300 kW)

• Pulse width optimized for minimal broadening in MPE microscope systems

• Ready for Chameleon OPO wavelength extension up to 1600 nm

• Ready for Chameleon PreComp module for negative dispersion

• Simple menu-driven GUI or RS-232 operator interface

• PowerTrack™ active alignment for long-term stability

• On-board spectrometer with simple USB interface shows wavelength

Laser Head – Top View

Laser Head – Front View

Laser Head – Side View

Laser Head – Rear View Power Supply – Side View

113.0 mm (4.45 in.)505.0 mm (19.88 in.)436.0 mm (17.17 in.)

269.0

mm

(10.5

9 in

.)

Laser Head – Bottom View

Power Supply – Front View

Mechanical Specifications

122 www.Coherent.com • [email protected] Reliability & Performance •

Page 125: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Chameleon Ultra FamilyWidely Tunable, Hands-Free, Modelocked Ti:Sapphire Lasers

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Chameleon systems. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Chameleon Ultra IITypical Tuning Curve

Wavelength (nm)

Typical Tuning Curve

Pow

er (W

)

0650 1100

4.5

0.51.01.52.02.53.03.54.0

700 750 800 850 900 950 1000 1050

Chameleon Ultra Chameleon Ultra I Chameleon Ultra IIAveragePower1(W) >2.5 >2.9 >3.5TuningRange(nm) 690to1020 690to1040 680to1080PeakPower1(kW) >200 >250 >300PowerSpecifications >650mWat680nm >500mWat690nm >600mWat690nm >1.6Wat700nm >1.4Wat710nm >1.5Wat710nm >2.5Wat800nm >2.9Wat800nm >3.5Wat800nm >1.4Wat920nm >1.45Wat920nm >1.6Wat920nm >450mWat1020nm >450mWat1020nm >550mWat1020nm >300mWat1040nm >200mWat1080nmTuningSpeed2(nm/s) >35 >40 >40PulseWidth1,3(fs) 140Noise1,4(%) <0.15OutputPowerStability5(%) <±0.5SpatialMode1 TEM00(M2<1.1)BeamDiameter1,6(mm) 1.2±0.2BeamEllipticity1,7 0.9to1.1Astigmatism1(%) <10RepetitionRate(MHz) 80Polarization Horizontal,>500:1Pointing(μrad/nm) <0.5

OperatingVoltage 90to250VAC(autoranging)MaximumOperatingCurrent <15Aat90VAC(powersupply) <7Aat90VAC(chiller) <2Aat90VAC(MRUX1)SystemPowerConsumption 2300Wmax.,1300WtypicalLineFrequency 47to63HzOperatingTemperatureRange 15to35°C(59to95°F)WeightofLaserHead 42kg(93lbs.)WeightofPowerSupply 41kg(90lbs.)UmbilicalLength 4m(13ft.)Chiller: Dimensions(LxWxH) 27x20x38cm(11x8x15in.) Weight 11kg(25lbs.)MRUAirRecirculator: Dimensions(LxWxH) 46x43x8.5cm(18x17x3in.) Weight 9kg(20lbs.)

System Specifications

Utility and Environmental Requirements

1 Specifiedatpeakoftuningrange.2 Averagespeedmeasuredoverentiretuningrange.3 Basedonsech2deconvolutionof0.65timesautocorrelationwidth.4 MeasuredRMSina10Hzto20MHzbandwidth.

5 Powerdriftinanytwo-hourperiodwithlessthan±1°Ctemperature changeafteraone-hourwarm-up.6 1/e2atexitport.7 Ratioofmajortominor1/e2beamdiameteratexitport.

123Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 126: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

120.65 mm(4.75 in.)

133.9 mm(5.27 in.)

Min. Bend RadiusR 152 mm

(6.0 in.)133.9 mm(5.27 in.)

369 mm(14.53 in.)

Output

530 mm(20.87 in.)

436 mm(17.17 in.)

505 mm(19.88 in.)

113 mm(4.45 in.)

269 mm(10.59 in.)

215.46 mm(8.48 in.)

326.2 mm(12.84 in.)

779.5 mm(30.69 in.)

189.2 mm(7.45 in.)

172.5 mm(6.79 in.)

Output

Laser Head – Front View

Laser Head – Rear View

Power Supply – Front View

Power Supply – Side View

Chameleon VisionWidely Tunable, Single Box Precompensation, Hands-Free, Modelocked Ti:S Laser

Features

• Hands-free operation

• Sealed maintenance-free design

• Ultrawide tuning range (400 nm)

• Automated dispersion precompensation in a single box

• Fully-controllable dispersion precompensation down to 0 at all wavelengths

• High output power (up to >3W)

• Ultra wide dispersion compensation range from 0 to >47,000 fs2

• Tuning above 920 nm provided by MRU air recirculator (included)

• Simple menu-driven GUI or RS-232 operator interface for laser and precompensation features

• PowerTrack™ active alignment for long-term stability

• On-board spectrometer with simple USB interface shows wavelength

Mechanical Specifications

Laser Head – Side View

Laser Head – Top View

Laser Head – Bottom View

124 www.Coherent.com • [email protected] Reliability & Performance •

Page 127: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Chameleon VisionWidely Tunable, Single Box Precompensation, Hands-Free, Modelocked Ti:S Laser

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Chameleon systems. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Vision I Vision IITuningRange(nm) 690to1040 680to1080AveragePoweratPeak(W) 2.5 3.0PowerSpecifications - 500mWat680nm 640mWat690nm - 1.07Wat710nm 1.5Wat710nm 2.5Wat800nm 3.0Wat800nm 920mWat920nm 1.35Wat920nm 260mWat1040nm 400mWat1040nm - 180mWat1080nmDispersionCompensationRange - 0to47,000fs2at680nm 0to43,000fs2at690nm - 0to22,000fs2at800nm 0to22,000fs2at800nm 0to10,000fs2at1020nm 0to10,000fs2at1020nm - 0to9,000fs2at1080nmTuningSpeed2(nm/s) >35 >40PulseWidth1,3(fs) 140Noise1,4(%) <0.15OutputPowerStability1,5 <±0.5SpatialMode1 TEM00(M2<1.1)BeamDiamater1,6(mm) 1.2±0.2BeamEllipticity1,7 0.9to1.1Astigmatism1(%) <10RepetitionRate(MHz) 80Polarization Horizontal>500:1Pointing(μrad/nm) <80/100total

OperatingVoltage(VAC) 90to250(autoranging)MaximumOperatingCurrent(A) <15at90VAC(powersupply) <7at90VAC(chiller) <2at90VAC(MRUx1)SystemPowerConsumption(W) 2300max.,1300typicalLineFrequency(Hz) 47to63OperatingTemperatureRange 15to35°C(59to95°F)WeightofLaserHead 52kg(115lbs.)WeightofPowerSupply 41kg(90lbs.)UmbilicalLength 3m(10ft.)Chiller: Dimensions(LxWxH) 27x20x38cm(11x8x15in.) Weight 11kg(25lbs.)MRUAirRecirculator: Dimensions(LxWxH) 46x43x8.5cm(18x17x3in.) Weight 9kg(20lbs.)

System Specifications

Utility and Environmental Requirements

1 Specifiedatpeakoftuningrange.2 Averagespeedmeasuredoverentiretuningrange.3 Basedonsech2deconvolutionof0.65timesautocorrelationwidth.4 MeasuredRMSina10Hzto20MHzbandwidth.

5 Powerdriftinanytwo-hourperiodwithlessthan±1°Ctemperature changeafteraone-hourwarm-up.6 1/e2atexitport.7 Ratioofmajortominor1/e2beamdiameteratexitport.

Chameleon Vision IITypical Tuning Curve

Maximum Negative Dispersion

0

10,000

20,000

30,000

40,000

50,000

650 700 750 800 850 900 950 1000 1050 1100

Wavelength (nm)

GD

D (f

s²)

Maximum Negative Dispersion CapabilityTheshadedregionrepresentstherangeofdispersionvaluesobtainablefromtheVision

Typical Tuning Curve

0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

650 700 750 800 850 900 950 1000 1050 1100

Wavelength (nm)

Pow

er (W

)

125Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 128: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

189.2 mm(7.45 in.)

172.5 mm(6.79 in.)

799.8 mm(31.49 in.)

134.7 mm(5.3 in.)

369 mm(14.53 in.)

326.2 mm(12.84 in.)

685.4 mm(26.99 in.)

59.8 mm(2.35 in.)

134.7 mm(5.3 in.)

269.5 mm(10.61 in.)

431.8 mm(17.0 in.)

497.6 mm(19.59 in.)

120.7 mm(4.75 in.)

Output

Output

Laser Head – Front View

Laser Head – Rear View

Power Supply – Front View

Chameleon Vision-SWidely-Tunable, High Peak Power, Single Box Precompensation, Hands-Free, Modelocked Ti:S Laser

Features

• Hands-free operation

• Sealed maintenance-free design

• Ultrawide tuning range (360 nm)

• Automated dispersion precompensation in a single box

• Fully-controllable dispersion precompensation down to 0 at all wavelengths

• High output power (up to 2.5W)

• Highest peak and average power

• Ultra wide dispersion compensation range from 0 to >43,000 fs2

• Tuning above 920 nm provided by MRU air recirculator (included)

• Simple menu-driven GUI or RS-232 operator interface for laser and precompensation features

• PowerTrack™ active alignment for long-term stability

• On-board spectrometer with simple USB interface shows wavelength

Mechanical Specifications

Laser Head – Side View

Laser Head – Top View

Laser Head – Bottom View Power Supply – Side View

126 www.Coherent.com • [email protected] Reliability & Performance •

Page 129: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Chameleon systems. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Chameleon Vision-SWidely-Tunable, High Peak Power, Single Box Precompensation, Hands-Free, Modelocked Ti:S Laser

TuningRange(nm) 690to1050AveragePoweratPeak(W) 2.5PeakPoweratPeak(kW) >440PeakPowerSpecifications 80kWat690nm 440kWat800nm 240kWat920nm 50kWat1050nmDispersionCompensationRange 0to43,000fs2at690nm 0to22,000fs2at800nm 0to9,500fs2at1050nmTuningSpeed2(nm/s) >25PulseWidth1,3(fs) 75Noise1,4(%) <0.15OutputPowerStability1,5 <±0.5SpatialMode1 TEM00(M2<1.1)BeamDiameter1,6(mm) 1.2±0.2BeamEllipticity1,7 0.9to1.1Astigmatism1(%) <10RepetitionRate(MHz) 80Polarization Horizontal>500:1Pointing(μrad/nm) <80/100total

OperatingVoltage(VAC) 90to250(autoranging)MaximumOperatingCurrent(A) <15at90VAC(powersupply) <7at90VAC(chiller) <2at90VAC(MRUx1)SystemPowerConsumption(W) 2300max.,1300typicalLineFrequency(Hz) 47to63OperatingTemperatureRange 15to28°C(59to82.5°F)StorageTemperatureRange 5to40°C(41to104°F)WeightofLaserHead 52kg(115lbs.)WeightofPowerSupply 33kg(73lbs.)UmbilicalLength 3m(10ft.)Chiller: Dimensions(LxWxH) 27x20x38cm(11x8x15in.) Weight 11kg(25lbs.)MRUAirRecirculator: Dimensions(LxWxH) 46x43x8.5cm(18x17x3in.) Weight 9kg(20lbs.)

System Specifications

Utility and Environmental Requirements

1 Specifiedatpeakoftuningrange.2 Averagespeedmeasuredoverentiretuningrange.3 Basedonsech2deconvolutionof0.65timesautocorrelationwidth.4 MeasuredRMSina10Hzto20MHzbandwidth.

5 Powerdriftinanytwo-hourperiodwithlessthan±1°Ctemperature changeafteraone-hourwarm-up.6 1/e2atexitport.7 Ratioofmajortominor1/e2beamdiameteratexitport.

Chameleon Vision-STypical Peak Power

Wavelength (nm)

Peak

Pow

er (k

W)

0

500

100

200

300

400

650 700 750 800 850 900 950 1000 1050 1100

Chameleon Vision-SDispersion Compensation Range

Wavelength (nm)

Neg

ativ

e D

ispe

rsio

n (fs

²)

0

50,000

10,000

20,000

30,000

40,000

700 750 800 850 900 950 1000 1050

127Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 130: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Chameleon PreCompAutomated Dispersion Control for Chameleon Ti:Sapphire Lasers

Features

• Automated dispersion tracking designed for MPE

• Continuous precompensation from 0 to -23,000 fs2 dispersion

• Single control link integration

• Matches ultra-wide tuning range of Chameleon lasers

• Ease of use with Chameleon lasers

• High transmission optical design

Mechanical Specifications464 mm (18.27 in.)

Beam Output

Beam Input

41 mm (1.61 in.)

166

to 2

10 m

m

(6.5

to 8

.3 in

.)

320

mm

(12

.6 in

.)10

6 to

150

mm

(4

.2 to

5.9

in.)

128 www.Coherent.com • [email protected] Reliability & Performance •

Page 131: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Chameleon PreCompAutomated Dispersion Control for Chameleon Ti:Sapphire Lasers

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Chameleon systems. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

System Specifications

Utility and Environmental Requirements

Interface Link for Automation

Maximum Negative Dispersion Capability

TuningRange(nm) 680to1080Transmission(%) >90acrossentiretuningrangeNegativeDispersionRange2 0to-23,000fs2

InputBeamParameter AcceptsallChameleonlasers

OperatingVoltage(VAC) 90to250(autoranging)SystemPowerConsumption(W) Typical 10 Maximum 20LineFrequency(Hz) 47to63OperatingTemperatureRange 15to35°C(59to95°F)Weight 11kg(22lbs.)Dimensions(LxWxH) OpticalHead 464x313x180mm(18.27x12.32x7.09in.) RemoteControlUnit 124x155x82mm(4.88x6.1x3.23in.)

Maximum Negative Dispersion

-30000

-25000

-20000

-15000

-10000

-5000

0

600 650 700 750 800 850 900 950 1000 1050 1100

Wavelength (nm)

GD

D (f

s²)

1 WhenoperatedwithChameleonTi:Sapphirelaser.2 At700nm.Maximumnegativedispersionisdependentonwavelength.Seediagrambelowfortypicalvalues.

ChameleonPreComp

Control UnitMicroscope

ChameleonTi:Sapphire Laser

Control Unit

129Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 132: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Chameleon MPXMultiphoton Microscopy Wavelength Extension

Mechanical Specifications

130 www.Coherent.com • [email protected] Reliability & Performance •

Features • Performance optimized for non-linear imaging applications

• 130 fs short pulses for high peak power

• GDD dispersion compensated output

• Automated, gap-free tuning from 680 nm to 1340 nm with Chameleon pump laser

• Independent wavelength tuning of both laser and OPO for simultaneous 2-color excitation and multimodal imaging

• Synchronized output pulse trains for CARS/SRS and wavelength mixing

Chameleon

158.7 mm(6.25 in.)

120.7 mm(4.75 in.)

120.7 mm(4.75 in.)

520 mm(20.47 in.)

520 mm(20.47 in.)

134 mm(5.28 in.)

369 mm(14.5 in.)

135 mm(5.3 in.)

Signal Out

Pump OutPump In

186.5 mm(7.34 in.)

Out In

60 mm to 150 mm(2.26 in. to 5.91 in.)

Chameleon MPX - Top View

Chameleon MPX - Side View

Chameleon - Side View

Chameleon and Chameleon MPX Table Layout

Page 133: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Chameleon MPXMultiphoton Microscopy Wavelength Extension

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.

Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.

Coherent offers a limited warranty for all Chameleon systems. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.

Pumped by Pumped by Chameleon Ultra II Chameleon Vision IITuningRange1(nm) 1010to1340 1010to1340PumpWavelengthRange(nm) 760to910 760to910OutputPower2(mW)(signal) >750 >7003

PumpOutputPowerAvailable4(%) whenpumpingOPO ~15 inbypassmode 95PulseWidth5(fs)(typical) 130OutputGDDPrecompensation6(fs2) -6000M2(typical) <1.1BeamDiameter(mm) 2BeamDivergence(mrad)(typical) 0.7Polarization HorizontalRepetitionRate(MHz) 80MHz,lockedtopumplaserDimensions(LxWxH) 520x369x158mm(20.5x14.5x6.2in.)

System Specifications

Chameleon MPXDual Tuning Range

1 TuningrangedependsonPumpWavelength.2 AtmaximumofpumpandOPOsignaltuningcurve.3 VisionDispersionsettingsoptimized.4 Typical.PleaserefertoChameleondatasheetforrespectivepowerspecifications.5 Typicalvalueatsampleplaneaftermicroscopedispersion.6 Typicalvalueat1100nm.

Chameleon MPXTypical Output Power

131Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

MPX

Sig

nal W

avel

engt

h (n

m)

1000

1050

1100

1150

1200

1250

1300

1350

750

Pump Wavelength from Chameleon (nm)770 790 810 830 850 870 890 910

Out

put P

ower

(mW

)

0

200

400

600

800

1000

1200

1000

Output Wavelength (nm)1050 1100 1150 1200 1250 1300 1350

Ultra II PumpVision II Pump

Page 134: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Lasers for Life Sciences Laser Measurement and Control Accessories

The FieldMaxII-TO laser power meter and PS10Q thermopile sensor provides power measurement from 100 µW to 1W with 10 µW resolution and spectral compensation from the UV to the IR. The meter features user selectable spectral correction, onboard statistical analysis, USB interface, analog output, and rechargeable batteries. The PS10Q is a thermally stabilized, amplified thermopile power sensor with a broad spectral response, high sensitivity, and a large active area. For the CUBE FP we are recommending the PS10 model and the optional FC fiber adapter.

Laser Meter Sensor AccessoryOBIS FieldMaxII-TO PS10QOBISFP FieldMaxII-TO PS10 FCFiberAdapterOBISLG355 FieldMaxII-TO PS10StructuredLightFlatTopProjector PleaseCallFactory PleaseCallFactoryCUBE FieldMaxII-TO PS10QCUBEFP(CollimatedBeam) FieldMaxII-TO PS10QCUBEFP(FC/PC) FieldMaxII-TO PS10 FCFiberAdapterRadius FieldMaxII-TO PS10QULN FieldMaxII-TO PS10QCompass115M FieldMaxII-TO PS10Q,OP-2VISCompass215M FieldMaxII-TO PS10Q,OP-2VISSapphireLP FieldMaxII-TO PS10QSapphireFP FieldMaxII-TO PS10QSapphireSF FieldMaxII-TO PS10QSapphireDriverUnit FieldMaxII-TO PS10QGenesisCXSeries FieldMaxII-TO PS10QGenesisMXSeriesSTM(OEM) FieldMaxII-TO PM10GenesisMXSeriesMTM(OEM) FieldMaxII-TO PM10ChameleonUltra FieldMaxII-TO PM10ChameleonVision FieldMaxII-TO PM10ChameleonVision-S FieldMaxII-TO PM10ChameleonPreComp N/A N/AChameleonMPX FieldMaxII-TO PM10

Product Name Part NumberFieldMaxII-TO 1098579OP-2VIS 1098313PM10 1097901PS10Q 1098400PS10 1098350FCFiberAdapter 0012-3863

Meter, Sensor and Accessory Compatibility

132 www.Coherent.com • [email protected] Reliability & Performance •

Page 135: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

OrderingWe accept orders online at www.Coherent.com (CUBE only), by phone, fax, e-mail or mail. When confirming an order that has been placed, please indicate “confirming” on the order.

PricingPrices indicated are current at the time of publication, but we reserve the right to change these without notice. Prices are FOB origin, and do not include freight, duty or any applicable taxes.

Please consult our local Sales Office or Distributor for Export prices.

Terms of PaymentAcceptable terms of payment for domestic orders include cash with order, major credit card, COD or Net 30 with prior approval of credit.

Export terms are strictly letter of credit, cash in advance or major credit card.

ShippingShipment means are at the discretion of Coherent, but we will attempt to meet your special requests. We do not take responsibility for any delays or damage caused by the shipper.

ReturnsReturns are accepted only after a return authorization number has been obtained from Coherent, and credit will be allowed for goods returned under authorization in good condition.

Order CancellationCancellation of orders will incur a termination charge of not less than 10% of the order value, and Coherent reserves the right to charge for all costs incurred in support of any cancelled order.

WarrantyGoods are warranted to be free from defects and to work in the manner specified for a period of 12 months from date of shipment. Extended warranty is available on some products.

SpecificationsSpecifications are current at the time of publication, but Coherent reserves the right to change these without prior notice.

Technical InformationThe technical information provided in this catalog is intended to be helpful in the application of Coherent products, but we do not accept responsibilty for its use.

Terms and Conditions of SaleTerms and Conditions of Sale are specific to each country in which Coherent operates. They are supplied with all quotations and invoices and can be sent by fax or mail on request. Nothing in the foregoing statements modifies the Terms and Conditions in effect for each country of operation.

Doing Business with Coherent

133Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 136: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

All Coherent product names are trademarks of Coherent, Inc.*All products indicated by an asterisk are registered trademarks of their respective companies.

Contact Us by Phone

Coherent, Inc.(800) 527-3786 or (408) 764-4983

Benelux: +31 (30) 280 6060

China: +86 (10) 8215 3600

France: +33 (0)1 8038 1000

Germany/Austria/Switzerland: +49 (6071) 968 333

Italy: +39 (02) 31 03 951

Japan: +81 (3) 5635 8680

Korea: +82 (2) 460 7900

Taiwan: +886 (3) 505 2900

United Kingdom/Ireland: +44 (0) 1353 658833

Contact Us by Email

Laser Products: [email protected]

Laser Measurement: [email protected]

Service: [email protected]

How to Contact Us

134

Page 137: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Use the Product and Application Finders below to quickly get more helpful details.

Extensive Laser Finder

Application Reports

Enhanced Application Finder

Technical Illustrations, Videos

Brochures, Tech Notes, Data Sheets

for more information about how Coherent can enable your Life Science laser application.

www.Coherent.com/LasersLifeSciences

Visit the Coherent Website

135Toll Free: (800) 527-3786 • Tel: (408) 764-4983 • Superior Reliability & Performance

Page 138: Lasers for Life Sciences - Coherent, Inc. · 2021. 1. 12. · Life science is important to improve our collective health and well-being, and providing the technology that is vital

Printed in the U.S.A. MC-006-10-0M0215Rev.NCopyright © 2015 Coherent, Inc.

VISIBLE AND INVISIBLE LASER RADIATION.AVOID EYE OR SKIN EXPOSURE TO

DIRECT OR SCATTERED RADIATION.CLASS II Ib LASER PRODUCT.

350 nm to 1100 nm<500 mW

VISIBLE AND INVISIBLE LASER RADIATION.AVOID EYE OR SKIN EXPOSURE TO

DIRECT OR SCATTERED RADIATION.CLASS IV LASER PRODUCT.

400 nm to 700 nm<10W

Coherent, Inc. 5100 Patrick Henry DriveSanta Clara, CA 95054United StatesToll Free: 1-800-527-3786Tel: (408) 764-4983Fax: (408) 764-4646www.Coherent.com

ChinaCoherent Inc., BeijingRoom 215 Yin Gu BuildingNo. 9 Beisihuan Xi RoadHaidian DistrictBeijing, 100080, ChinaTel: +86-10-8215-3600Fax: +86-10-6280-0129www.Coherent.com.cn

FranceCoherent FranceParc Technopolis3, Avenue du CanadaBâtiment Zeta91978 Courtaboeuf cedexFranceTel: +33-1-80-38-10-00Fax: +33-1-80-38-10-01www.Coherent.fr

Germany/Austria/SwitzerlandCoherent GmbHDieselstraße 5bD-64807 DieburgGermanyTel: +49-6071-968-333Fax: +49-6071-968-499www.Coherent.de

ItalyCoherent ItaliaVia Borgese, 14Milano, 20154ItalyTel: +39-02-31-03-951Fax: +39-02-31-03-95-55www.Coherent.it

JapanCoherent Japan, Inc. Toyo MK Building7-2-14 ToyoKoto-ku, Tokyo 135-0016JapanTel: +81 3-5635-8680Fax: +81 3-5635-8701www.Coherent.co.jp

KoreaNo. 101, Eagle Town278-20, 3 dongSeongsu 2 gaSeongdong-gu, Seoul133-832, South KoreaTel: +82 2 460 7900www.Coherent.com

NetherlandsCoherent B.V.Smart Business Park Kanaalweg 18A3526 KL UtrechtNetherlandsTel: +31-30-280-6060Fax: +31-30-280-6077www.Coherent.nl

TaiwanCoherent Taiwan2F-5, No. 38. Taiyuan St.Zubei City, Hsinchu County 30265TaiwanTel: +886-3-505-2900www.Coherent.com

United Kingdom/IrelandCoherent UK Ltd.St Thomas’ PlaceCambridgeshire Business ParkElyCB7 4EXEnglandTel: +44-1353-658-833Fax: +44-1353-659-110www.Coherent.com