lecture 5

25

Upload: gimusi

Post on 28-Dec-2015

14 views

Category:

Documents


0 download

DESCRIPTION

Geosynthetics in Civil Engineering

TRANSCRIPT

Page 1: Lecture 5
Page 2: Lecture 5

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Prof. J. N. Mandal

Department of Civil Engineering, IIT Bombay, Powai , Mumbai 400076, India. Tel.022-25767328email: [email protected]

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 3: Lecture 5

Module - 1LECTURE - 5

INTRODUCTION TO REINFORCED EARTH

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 4: Lecture 5

RECAP of previous lecture…..

Standard Analysis of Reinforced Earth

Internal local stability

Critical slip surface for inextensible reinforcement

Critical slip surface for extensible reinforcement

Calculation of maximum tensile forces in thereinforcement layers

Design an inextensible steel reinforced soil retainingwall (partly covered)

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 5: Lecture 5

Calculation of eccentricity at base (e):

r

oR

WMM

2Le

MR = Wr x L/2 = 1077.3 x (6.3/ 2) = 3393.495 kN-m/m

Mo = Fa x H/3 + Fq x H/2 = (256.5 x 9/3 + 30 x 9/2) kN-m/m= 904.5 kN-m/m

1.056L0.839599

3.10775.904495.3393

23.6e (OK)

Factor of safety against overturning, FSoverturning = MR/ Mo = 3393.495/ 904.5 = 3.75 > 2 (OK)

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 6: Lecture 5

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 7: Lecture 5

e2LWW

e2LV qr

v

kPa300kPa 246.7884.023.6

631077.3v

Calculation of bearing pressure at base

Effective length = (L - 2e)

Total vertical pressure over the foundation soil = σv

(OK)

Given allowable bearing capacity of foundation soil = 300 kPa

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 8: Lecture 5

Step 3: Check internal stability

The complete calculations along the entire height at eachreinforcement level are presented in a tabular form at theend.

The hand calculations for internal stability are performed at adepth, z = 4.875 m.

307.0)2/3245(tan)2/45(tanK 2rar

2

As z < 6 m (z = 4.875 m), from interpolation,

398.06

)z6(5.02.1KK arr

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 9: Lecture 5

Variation of stress ratio with depthProf. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 10: Lecture 5

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

65.0

z6x

Page 11: Lecture 5

Now, at this level vertical pressure (σv)= γr x z + q = 19 x 4.875 + 10 = 102.625 kPa

Horizontal pressure (σh)= Kr x σv = 0.398 x 102.625 = 40.795 kPa

Consider tributary area (At) over twice the panel width todetermine the horizontal spacing among reinforcementsand check the pull-out criteria.

At = 2 x panel width x Sv = 2 x 1.5 x 0.75 = 2.25 m2

The maximum horizontal force on this tributary area (Tmax)= σh x At = 40.795 x 2.25 = 91.789 kN

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 12: Lecture 5

Considering factor of safety against pull-out failure (FSpull-out)≥ 1.5,

Pull-out resistance (PR) ≥ 1.5 x T = 1.5 x 91.789 = 137.683 kN

If the minimum number of reinforcements required in thetributary area to achieve the pullout resistance = N

'L*Fb2PN

ve

R

b = width of reinforcement strip = 50 mmLe = embedded length of reinforcement = L – Laσv' = vertical pressure ignoring the surcharge pressureF* = 1.2 + log Cu at the top of the structure = 2 (maximum)

= tanϕr (at z ≥ 6 m)Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 13: Lecture 5

Variation of friction factor (F*) with depth

6)z6)(tan2(tan*F r

r

883.06

)875.46)(32tan2(32tan*F

As z < 6 m, From interpolation

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 14: Lecture 5

As z > H/2 = 4.5 m,

La = length of reinforcement in active zone= 0.6(H - Z) [From interpolation]= 0.6 x (9 - 4.875)= 2.475 m

Le = L – La = 6.3 – 2.475 = 3.825 m

σv' = vertical pressure at this level ignoring the surchargepressure = (102.625 – 10) = 92.625 kPa

403.4625.92825.3883.005.02

683.137'L*Fb2

PN

ve

R

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 15: Lecture 5

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 16: Lecture 5

Hence, Nactual = 5 (it should be an integer)In the tributary area 5 numbers of strips should be providedin a row.

Approximate horizontal spacing (Sh) can be = (2 x panel width)/ N = (2 x 1.5)/ 5 = 0.6 m

Now, the corrected pull-out resistance PR(actual)

= 2 x b x F* x Le x σv' x Nactual

= 2 x 0.05 x 0.883 x 3.825 x 92.625 x 5

= 156.367 kN

Therefore, factor of safety against pull-out failure, FSpull-out = PR(actual)/ T = 156.367/ 91.789 = 1.704

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 17: Lecture 5

Step 4: Calculation of stress in metallic strip duringdesign life

Initial thickness of the metallic strip reinforcement made ofsteel including the zinc coating of 0.086 mm = 5 mm

According to FHWA (1990), the thickness losses per yearare as follows:

• zinc loss = 0.015 mm/ year (first 2 years)= 0.004 mm/ year (thereafter)

• steel loss = 0.012 mm/ year/ side (thereafter)

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 18: Lecture 5

Time for complete zinc loss= 2 years + [{0.086 – 2 x 0.015}/ 0.004] = 16 years

Steel loss will be for (75 – 16) = 59 years during design life.

Total thickness loss during design life (tloss)= 2 x 0.012 x 59 = 1.416 mm

Remained thickness (tremained)= 5 – 1.416 = 3.584 mm = 0.003584 m

Remained cross-section after design life of 75 years (Ac)

= 0.003584 x 0.05 = 0.0001792 m2

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 19: Lecture 5

fy = 413.7 MPA (60 grade steel)

fallowable = 0.55 (fy) = 227.5 MPA

The tensile stress (fs) in each strip,

MPA5.227MPA44.1020001792.05

789.91AN

Tfc

s

(OK)

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 20: Lecture 5

INTERNAL STABILITY strip thickness (m)

0.005 DETAILED CALCULATIONS

Panel width (m)

1.5Tributary area

At (m2)2.25 tloss (m) 0.00142

AC

(m2)0.0001792

Spacing (Sv) (m)

0.75Strip width (b)

(m)0.05 tremained (m) 0.00358

FS pullout

≥1.5

Depth (z) (m)

Vertical pressure

(kPa)Kar Kr

Horizontal

Pressure (kPa)

F* La (m) Le (m)

Max. hor. force/ trib. area (Tmax)

(kN)

PR (kN)

N strips per trib. area

Nactual

Approx hor.

spacing (Sh) (m)

PR(actual) (kN)

Tensile stress, fs (MPA)

FS pullout

0.375 17.125 0.307 0.513 8.781 1.914 2.7 3.6 19.756 29.64 6.04 7 0.43 34.367 15.75 1.7401.125 31.375 0.307 0.494 15.49 1.742 2.7 3.6 34.840 52.26 3.89 4 0.75 53.624 48.61 1.5391.875 45.625 0.307 0.474 21.64 1.570 2.7 3.6 48.693 73.04 3.63 4 0.75 80.555 67.93 1.6542.625 59.875 0.307 0.455 27.25 1.398 2.7 3.6 61.314 91.97 3.66 4 0.75 100.43 85.54 1.6383.375 74.125 0.307 0.436 32.31 1.226 2.7 3.6 72.704 109.06 3.85 4 0.75 113.25 101.43 1.5584.125 88.375 0.307 0.417 36.83 1.055 2.7 3.6 82.862 124.29 4.18 5 0.6 148.78 92.48 1.7954.875 102.625 0.307 0.398 40.8 0.883 2.475 3.825 91.789 137.68 4.40 5 0.6 156.37 102.44 1.7045.625 116.875 0.307 0.378 44.22 0.711 2.025 4.275 99.484 149.23 4.6 5 0.6 162.38 111.03 1.6326.375 131.125 0.307 0.369 48.35 0.625 1.575 4.725 108.781 163.17 4.56 5 0.6 178.81 121.41 1.6447.125 145.375 0.307 0.369 53.60 0.625 1.125 5.175 120.603 180.90 4.13 5 0.6 218.88 134.60 1.8157.875 159.625 0.307 0.369 58.86 0.625 0.675 5.625 132.425 198.64 3.78 4 0.75 210.37 184.74 1.5898.625 173.875 0.307 0.369 64.11 0.625 0.225 6.075 144.246 216.37 3.48 4 0.75 248.83 201.24 1.725

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 21: Lecture 5

Cantilever Retaining Wall

Braced Excavation Soil Nailing

Gravity Retaining Wall

Sheet Pile Wall

Conventional systems

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 22: Lecture 5

High Cost Long term susceptibility to corrosion. Sustainability depends on the correct choice of Backfill

material ( i.e. gradation, chemical properties etc.) Cannot be used with many indigenous materials. Back fill material cost is about 30 to 40%of the total cost of the reinforced soil wall.

Mechanically stabilized reinforced earth using metal strips

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 23: Lecture 5

It is preferable to use non corrosive materials likepolymer geosynthetics as a reinforcement.

Polymer does not corrode,

Economical, and

Used with many other indigenous materials

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 24: Lecture 5

Please let us hear from you

Any question?

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay

Page 25: Lecture 5

Prof. J. N. Mandal

Department of civil engineering, IIT Bombay, Powai , Mumbai 400076, India. Tel.022-25767328email: [email protected]

Prof. J. N. Mandal, Department of Civil Engineering, IIT Bombay