led 1000w omni-cob tm...high performance led omni-cob lamp, 200w omni-cobtm led 1000w mh / hps...
TRANSCRIPT
Page: 1 of 2
Incandescent HPS/HID CFL HyLite
2000W 1000W 650W 200W
90% 80% 70% Energy Savings (%)*
* Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%!
Replacewith
200WHL-OC-200W-E39
100-277V, AC
5" (125mm)
5” (1
25m
m)
High Performance LED Omni-Cob Lamp, 200W
OMNI-COB TM
LED 1000WMH / HPSEquivalent
The HyLite High Performance LED Omni-Cob Lamp is an Energy-Efficient Replacement for use in a Wide Variety of New or Retrofit Applications. It features Excellent Optics for increased Visibility and Security, with a 360° Beam to evenly illuminate the area.
It is an Excellent Alternative to Standard CFL, MV, MH, or HPS and is ideal for High Bay, Area, Street and Security Lighting Applications. With a Lamp Life of up to 60K hours, the HyLite LED Omni-Cob Lamps significantly reduce Relamping costs, thus decreasing Maintenance and Disposal costs.
• HighestLumenEfficacyinits’class:140LpWwithHighCRI:>80
• FullyEncapsulated:Shatter-proof,High-Shock&High-VibrationResistant
•BrilliantLightforgreaterVisibilityandSafety.
• EasyInstallation:NoBallastnecessary.DirectRetrofitintoexistingSocket
•InstantStartandRestart:NoWarm-upTimerequired
• Heat&ImpactResistant,UVProtected,Non-yellowing,OpticalGradeLens
• GoodHeatDissipationwithProprietary-designedHeatSink
• CoolOperation:DoesnotaddtoHeatLoadwhileproducingBrilliantLight
• SafeandReliable:IncludesaFree20kAin-lineSurgeProtectionDevice for added Protection
•NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)
• IngressProtection:IP65.CompleteprotectionagainstContact,Dust Infiltration, and Splashed Water
•Eco-Friendly:ContainNoHazardousMaterials;RoHSCompliant: NoLead,Mercury,ToxicMetalsorArsenicGases.NoDisposal requirements.FacilitatesLEED® points.
•IdealforusewithRenewableEnergyResources–Solar&WindPower
•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable
HyLiteHighPerformanceLEDOmni-CobLamps-Upto60,000hour*Rated Design Life. Outstanding Quality of Light with Energy Savings of 90%overIncandescent,80%overHPS/MHLampsand70%overCFL.
FREE!20 kA
In-line Surge Protection Device Included.
Additional Protection for your HyLite
Omni-Cob Lampat no Cost!
NOLEAD, MERCURY, HEAVY METALS
OR TOXIC GASES
98%RECYCLABLE
*Depending upon the ambient temperature of the installation location
8.3”
(212
mm
)
Ø 5.9” (149mm)
14.1”
(359
mm
)
1.6”
(40m
m) 5
.8” (
147m
m)
200WHL-OC-200W-E39
36V, DC
E39/
E40
Minimum Lamp Compartment Size 9.25” x 9.25” x 17.5” (235 x 235 x 440mm)
WARNING!
HyLite 200W LED Omni-Cob Lamp is Not Suitable for Enclosed Fixtures andfor Horizontal Installation
Caution: The Lamp has been provided with a Safety Cable. It is imperative to Secure Safety Cable to the Fixture, when installed in Vertical Installation.
Reliable andLong-Lasting
Warranty
5years
Vibration andShock Resistant
Solid State
Radiation-FreeNo Humming
IRUV
No IR/UV
No Noise
140 LpWLM-79 Tested
High Efficacy
LM-80 TestedISTMT Tested
Reliability
Reduction ofup to 90%
Energy Costs
Up to 60,000 Hours
Low Voltage
Longer Life&
360°Illumination
Zero Interference
No EMi / RFi
Page: 2 of 2
Model Delivered Maximum InputLine Base Dimensions&Weight(each) No. Watts Lumens Install Height Current Type Diameter Height Weight
HL-OC-200W-E39* 200 28000 <45ft.(15m) 722mA~2.0A E39/EX-39/E40 5.9”(149mm) 14.1”(359mm) 4lb.(1.8kg)
OMNI-COB TM
LED
Photometrics
Intensity: (Unit, cd) C0/180, 278.6°
Average Beam Angle (50%): 279.3°
C90/270, 277.9°
030
60
90
120
150-/+180
-150
-120
-90
-60
-30
0
300
600
900
1500
1200
As part of the company’s continuous product improvement program, HyLite reserves the right to change materials or modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.
CAUTION!Comes with External Driver. DO NOT Install without the Driver.
Warning: Read and Understand ALL Installation Instructions before installing or relamping with HyLite LED Omni-Cob Lamp. DO NOT Install without the Driver. Failure to follow instructions can result in a damaged product and will VOID Warranty.
*Depending upon the ambient temperature of the installation location
Ideal for high-quality illumination in:
• AreaLighting • HighBayLighting • WarehouseLighting
• Manufacturing • Gymnasiums • ColdStorage
• Arena • HighCeiling • UtilityandPowerGeneration
Minimum Lamp Compartment Size 9.25” x 9.25” x 17.5” (235 x 235 x 440mm)
WARNING!
HyLite 200W LED Omni-Cob Lamp is Not Suitable for Enclosed Fixtures andfor Horizontal Installation
Caution: The Lamp has been provided with a Safety Cable. It is imperative to Secure Safety Cable to the Fixture, when installed in Vertical Installation.
Installation: HyLite LED Lampsaredesignedtoworkoff100Vto277V,AC.Ballast(ifequipped)mustbebypassedor removed from the fixture before installing the lamp. Eliminating the Ballast saves additional costs related to Maintenance, Energy Consumption and Performance. By-passingBallastwillalsoensurethatthereisnoEMi/RFinterference. The installer MUST ensure and verify that NO Part of the installed LED Lamp should touch the Fixture Housing or Components.
Failure to follow these Instructions will result in a Damaged Product and will VOID Warranty. It could also result in an ElectricShock,orFire.
Warning - Risk of Fire or Electric Shock
• Disable all Power to the Lamp before Inspection, Installation, or Removal. Failure to do so will createaHazardousandFatalWorkingEnvironment.
• SuitableforuseinDry,DampandWetLocations.LampmustbeinstalledinaccordancewithNational,State,and/orLocalElectricalCodes. DoNotOpen–NoUserServiceablePartsInside.
• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation. ThiswillensureLumenMaintenanceandextenditsWorkingLife.WhenproductsareusedinOutdoorFixtures,ensurethespaceisWaterproofandWellVentilated.
• NotforuseonaDimmerorRemoteControls.ThisLamp must be controlled only by either a Switch or an Electronic Photosensor. Do not use a Mechanical Sensor.
• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.
• Caution:WhenInstallingLampsinCorrosiveEnvironments,HyLitesuggeststhataHigh-Temperature,Moisture-Resistant,SiliconeGreaseorSealantbeusedto protecttheMetal-threadedbaseoftheLEDLamptopreventWaterand/orMoistureIncursionthatcanleadtoPrematureDegradationoftheLampBaseand eventual Lamp Failure. This is especially recommended for LED Lamp installations near Saltwater bodies.
• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.
©2012-2019HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:https://hyliteledlighting.com/ 031219
• MinimumLampCompartmentDimensionsforEnclosedFixtures:9.25”x9.25”x17.5”(235mmx235mmx440mm)
• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-40°C(-40°F)toaMaximumof+55°C(131°F)
• Efficacy:140LpW • CRI:>80 • BeamAngle:360º • Max.THD(%):<15% • UniversalInputVoltage
• PowerFactor:>0.9 • Protection:IP65 •RatedLife:50~60,000Hrs. • Warranty:5Years 100~277V,AC50/60Hz.
• 347V,480VAvailable with with External Step-Down Transformer only. Please see HL-DT-215VA-480-277VSpec.Sheetat:https://hyliteledlighting.com/resources/specification-sheets/
• CCT:5000°K~5500°Kforgreatervisibility.Productswith2400°K-6500°K(CCT)areavailableas“SpecialOrders” only and with Longer Lead Times