ledblock g3 high power led retrofit module part … · 1000 w hid. occupied (high light level)...

17
The LEDBLOCK is a patented extruded aluminum design that replaces HID, HPS, or MH lamps. The installation bracket of the LEDBLOCK G3 comes partially assembled for a quick and easy installation. The innovative mounting brackets allow for a virtually unlimited amount mounting styles. The LEDBLOCK G3 can be mounted in either vertical or horizontal configuration. Outshine the competition with 165lm/w efficacy and 5/10 year warranty! PART NUMBER BUILDER 750 740* * Custom Order 65L 100L 150L 200L 300L 400L** 10VDIM 0-10VDIMMABLE HV* 348-480VAC LEDDRIVER (dimmable option is not available) INTEGRATED OCCUPANCY SENSOR (ON/OFF Control) RPT LEDBLOCK ORDERING EXAMPLE RPT-LEDBLOCK-65L-750-G3 Simplified instructions. Reference full installation guide for more details. Only qualified personnel should perform installation. CERTIFICATIONS PERFORMANCE LISTINGS Information is subject to change without notice. Suitable for damp locations 3 4 LEDBLOCK G3 OCC-HC419S HIGH POWER LED RETROFIT MODULE PROJECT NAME PARTNUMBER MANUFACTURER MODEL NUMBER LUMINOUS FLUX CRI/CCT OPTIONS Turn off power to the fixture. Remove bulb and existing ballast or cut the wires to the ballast and bypass it. Remove reflector to allow for better air flow. 1 Assemble desired mounting hardware to LED module head. Attach mounting brackets to fixture housing with screws. Wire the output of the LED driver to the LEDBLOCK and connect the input of the LED Driver to the AC power source. REMOVE THE PLASTIC COVER FROM THE LED MODULE. Re-assemble remaining parts of the fixture and turn on power. 2 3 4 INPUT VOLTAGE EFFICACY OPERATING TEMP MAX. CASE TEMP POWER FACTOR/THD CRI BEAM ANGLE RATED LIFE WARRANTY 120-277V AC 165 LPW -30˚C to 45˚C 50˚C >0.9 Power Factor, THD<15% 70+ 120˚ L70 LED Lifetime > 100,000 hrs 5 years on driver, 10 years on LEDBLOCK QUICK SPECS DIMENSIONS ** Dimmable option is not available Kits are stocked with a non-dimmable driver INTEGRATED OCCUPANCY SENSOR (bi-level dimming) 10VDIM-OCC-HC419V INTEGRATED OCCUPANCY SENSOR WITH WIRELESS GROUPING 10VDIM-OCC-HC428V/RF INSTALLATION GUIDE G3 GEN DIMENSIONS(INCHES) A B C D E RPT-LEDBLOCK-65L-G3 4.72 4.72 5.21 9.06 5.20 RPT-LEDBLOCK-100L-G3 4.72 4.72 5.21 9.06 5.20 RPT-LEDBLOCK-150L-G3 5.11 6.10 5.61 10.93 5.08 RPT-LEDBLOCK-200L-G3 5.11 6.10 5.61 10.93 5.08 RPT-LEDBLOCK-300L-G3 5.90 7.88 6.39 11.81 5.08 RPT-LEDBLOCK-400L-G3 10.00 10.63 10.47 16.93 5.06 A B C D E

Upload: others

Post on 28-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

The LEDBLOCK is a patented extruded aluminum designthat replaces HID, HPS, or MH lamps. The installationbracket of the LEDBLOCK G3 comes partially assembledfor a quick and easy installation. The innovativemounting brackets allow for a virtually unlimited amountmounting styles. The LEDBLOCK G3 can be mounted ineither vertical or horizontal configuration. Outshine thecompetition with 165lm/w efficacy and 5/10 yearwarranty!

PART NUMBER BUILDER

750740*

* Custom Order

65L100L150L200L300L400L**

10VDIM0-10VDIMMABLE

HV*348-480VAC LEDDRIVER(dimmable option is not available)

INTEGRATED OCCUPANCY SENSOR (ON/OFF Control)

RPT LEDBLOCK

ORDERING EXAMPLERPT-LEDBLOCK-65L-750-G3

Simplified instructions. Reference full installation guide for more details. Only qualified personnel should perform installation.

CERTIFICATIONS

PERFORMANCE LISTINGS

Information is subject to change without notice.

Suitable fordamp locations

3 4

LEDBLOCK G3

OCC-HC419S

HIGH POWER LED RETROFIT MODULE

PROJECT NAME

PARTNUMBER

MANUFACTURER MODEL NUMBER LUMINOUS FLUX CRI/CCT OPTIONS

Turn off power to the fixture. Remove bulb and existing ballast or cut the wires to the ballast and bypass it. Remove reflector to allow for better air flow.

1

Assemble desired mounting hardware to LED module head. Attach mounting brackets to fixture housing with screws.

Wire the output of the LED driver to the LEDBLOCK and connect the input of the LED Driver to the AC power source.

REMOVE THE PLASTIC COVER FROM THE LED MODULE. Re-assemble remaining parts of the fixture and turn on power.

2 3 4

INPUT VOLTAGE

EFFICACY

OPERATING TEMP

MAX. CASE TEMP

POWER FACTOR/THD

CRI

BEAM ANGLE

RATED LIFE

WARRANTY

120-277VAC

165 LPW

-30˚C to 45˚C

50˚C

>0.9 Power Factor, THD<15%

70+

120˚

L70 LED Lifetime > 100,000 hrs

5 years on driver, 10 years on LEDBLOCK

QUICK SPECS DIMENSIONS

** Dimmable option is not availableKits are stocked with a non-dimmable driver

INTEGRATED OCCUPANCY SENSOR (bi-level dimming)

10VDIM-OCC-HC419V

INTEGRATED OCCUPANCY SENSOR WITH WIRELESS GROUPING

10VDIM-OCC-HC428V/RF

INSTALLATION GUIDE

G3GEN

DIMENSIONS(INCHES) A B C D E

RPT-LEDBLOCK-65L-G3 4.72 4.72 5.21 9.06 5.20

RPT-LEDBLOCK-100L-G3 4.72 4.72 5.21 9.06 5.20

RPT-LEDBLOCK-150L-G3 5.11 6.10 5.61 10.93 5.08

RPT-LEDBLOCK-200L-G3 5.11 6.10 5.61 10.93 5.08

RPT-LEDBLOCK-300L-G3 5.90 7.88 6.39 11.81 5.08

RPT-LEDBLOCK-400L-G3 10.00 10.63 10.47 16.93 5.06

A

B

C

D

E

Page 2: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL FACTORY INSTALLED OCC SENSOR

ORDERING GUIDE

This fixture can be paired with our integral occupancy sensor for maximum energy savings. Unlike traditional passive infrared sensors (PIR) or Ultrasonic occupancy sensors, this high-frequency sensor can be hidden behind the lens eliminating the need for an external sensor and providing a clean look.

(DIMMED)

P Kits are DLC Premium xx 40 (4000K), 50 (5000K)

01.17

CASEQTY

ENERGY STAR DLC PART #

LUMEN OUTPUT (LM) WATTAGE (W)

VOLTAGE RANGE (VAC) WARRANTY (YRS)

TRADITIONAL EQUIVALENT

6 P RPT-LEDBLOCK-65L-7xx-G3 5100 30 @ 120 V30 @ 277 V

120-277 5 Years (Driver)10 Years (LEDBLOCK)

150 W HID

6 P RPT-LEDBLOCK-100L-7xx-G3 8850 52 @ 120 V52 @ 277 V

120-277 5 Years (Driver)10 Years (LEDBLOCK)

250 W HID

6 P RPT-LEDBLOCK-150L-7xx-G3 15700 99 @ 120 V97 @ 277 V

120-277 5 Years (Driver)10 Years (LEDBLOCK)

360 W HID

6 P RPT-LEDBLOCK-200L-7xx-G3 20000 124 @ 120 V124 @ 277 V

120-277 5 Years (Driver)10 Years (LEDBLOCK)

400 W HID

6 P RPT-LEDBLOCK-300L-7xx-G3 24000 150 @ 120 V150 @ 277 V

120-277 5 Years (Driver)10 Years (LEDBLOCK)

400 W HID

3 P RPT-LEDBLOCK-400L-7xx-G3 43000 277 @ 120 V270 @ 277 V

120-277 5 Years (Driver)10 Years (LEDBLOCK)

1000 W HID

OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHT LEVEL)

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

Page 3: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

UNIQUE FEATURES

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

Made of high strength 6063 Aluminum which allows for a lighter and thinner heat sinkADVANCED CIRCUIT DESIGN with

short circuit / over current /over voltage/over temperature protection with auto fault recovery

Nichia LEDs - up to 165 LM/W (system)

40% larger heat sink allows for much higher heat dissipation than other competitors!

UL listed Metal Clad PCB (MCPCB)

Weighs 30% less for a more durable retrofit!

INCLUDED INSTALLATION BRACKET

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

Page 4: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

TYPICAL APPLICATIONS

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

WALL PACK

FLOOD LIGHT

SHOE BOX

Page 5: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

TYPICAL APPLICATIONS

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

CANOPY

CIRCULAR HIGH BAY

Page 6: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC419S CONTROL MODULE) - WIRING

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

LED DriverL N

L

N

To LEDBLOCK

+ -

• 1 Sensor controlling 1 LED driver.

• ON/OFF Control

Page 7: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC419S CONTROL MODULE) – APPLICATION SCENARIO

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

Occupancy detected No Occupancy No Occupancy

Lig

ht L

evel

(%)

100%

Hold-Time

State 1 State 2 State 3

Fixture is OFF

Page 8: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC419S CONTROL MODULE) – CONFIGURATION

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

Hold-Time Daylight threshold

Detection Area

1 2 3 4 Hold-Time

I • • • • 5 secs

II o • • • 30 secs

III • o • • 1 min

IV • • o • 5 min

V • • • o 10 min

VI • • o o 20 min

VII o o o o 30 min

1 2 3 4 Light Levels

I • • • • Disabled

II o • • • 50 Lux

III • o • • 10 Lux

IV o o o o 2 Lux

1 2 3 4 Detection Area

I • • • • 100%

II o • • • 75%

III • o • • 50%

IV • • o • 30%

V o o o o 10%

Factory Default Settings:Detection range: 100%Hold-time: 5 secsDaylight sensor: Disabled

Page 9: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC419V CONTROL MODULE) – WIRING

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

LED DriverL N1-10V

L

N

To LEDBLOCK

+ -

• 1 Sensor controlling 1 LED driver.

• Control is achieved via 0-10V dimming.

• The OCC module has a built-in relay (or switch) that can disconnect power to the LED driver when no occupancy is detected.

Page 10: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC419V CONTROL MODULE) – APPLICATION SCENARIO

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

Occupancy detected No Occupancy No Occupancy No Occupancy

Lig

ht L

evel

(%)

100%

Stand-by dimming level

Hold-Time Stand-by dimming time

dimmed Fixture is OFF

State 1 State 2 State 3 State 4

Page 11: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC419V CONTROL MODULE) – CONFIGURATION

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

1 2 3 Hold-Time

I • • • 5 secs

II • • o 30 secs

III • o • 1 min

IV • o o 5 min

V o • • 10 min

VI o • o 20 min

VII o o o 30 min

1 2 Light Levels

I • • Disabled

II • o 50 Lux

III o • 10 Lux

IV o o 2 Lux

1 2 Stand-by dimming level

I • • 10%

II • o 20%

III o • 30%

IV o o 50%

Hold-Time Daylight threshold Stand-by period Stand-by dimming level

See next page to understand behavior when stand-by period is set to ‘forever’

Note:If enabled, when there is enough daylight, the fixture will remain OFF. The daylight threshold is disabled if the stand-by period is set to ‘forever’

Detection Area

1 2 Detection Area

I • • 100%

II • o 75%

III o • 50%

IV o o 10%Factory Default Settings:Detection range: 50%Hold-time: 5 minStand-by period: ForeverStand-by dimming level: 100%Daylight sensor: Disabled

1 2 3 Stand-by time

I • • • 0 secs

II • • o 10 secs

III • o • 1 min

IV • o o 5 min

V o • • 10 min

VI o • o 30 min

VII o o • 1 hr

VIII o o o Forever

Page 12: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC419V CONTROL MODULE) – APPLICATION SCENARIO

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

Occupancy detected No Occupancy No Occupancy No Occupancy

Lig

ht L

evel

(%)

Time

100%

Stand-by dimming level

Hold-Time Stand-by dimming time is forever

dimmed dimmed

Note:The daylight threshold is disabled if the stand-by period is set to ‘forever’

State 1 State 2 State 3 State 3

Page 13: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC428V/RF CONTROL MODULE) – WIRING

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

LED DriverL N1-10V

L

N

To LEDBLOCK

+ -

• 1 Sensor controlling 1 LED driver.

• Control is achieved via 0-10V dimming.

• The OCC module has a built-in relay (or switch) that can disconnect power to the LED driver when no occupancy is detected.

• Fixtures can communicate wirelessly with each other for group level behavior.

LED DriverL N1-10V

L

N

To LEDBLOCK

+ -

Fixture 1

Fixture 2

Transceiver

Transceiver

Two way RF communication between fixtures

Page 14: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC428V/RF CONTROL MODULE) – APPLICATION SCENARIO

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

Occupancy detected No OccupancyUnder this fixture

dimmed dimmed

Fixture 1 Fixture 2 Fixture 3 Fixture 4

dimmed

No OccupancyUnder this fixture

No OccupancyUnder this fixture

When fixture 1 detects motion, it turns on at full brightness (100%) and then sends an RF signal to the other fixtures, in its group, to turn on at the programmed stand-by dimming level.

No Occupancy, hold-timer initiated

Occupancy Detected

dimmed dimmed

Fixture 1 Fixture 2 Fixture 3 Fixture 4

No OccupancyUnder this fixture

No OccupancyUnder this fixture

As the occupant moves under fixture 2, its light level will increase to 100% and it also sends an RF signal to the other fixtures in its group.

Page 15: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC428V/RF CONTROL MODULE) – APPLICATION SCENARIO

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

dimmed dimmed

Fixture 1 Fixture 2 Fixture 3 Fixture 4

No OccupancyUnder this fixture

dimmed

Fixture 1 Fixture 2 Fixture 3 Fixture 4

As the occupant moves under fixture 4, its light level will increase to 100% and it also sends an RF signal to the other fixtures in its group. The hold-timer of fixture 2 now has expired and the fixture has returned to its stand-by dimming level. The hold-timer of fixture 3 is now initiated.

Hold-timer expired No Occupancy, hold-timer initiated

Occupancy Detected

As the occupant moves under fixture 3, its light level will increase to 100% and it also sends an RF signal to the other fixtures in its group. The hold-timer of fixture 1 now has expired and the fixture has returned to its stand-by dimming level. The hold-timer of fixture 2 is now initiated.

No OccupancyUnder this fixture

No OccupancyUnder this fixture

dimmed

No Occupancy, hold-timer initiated

Occupancy Detected

Page 16: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC428V/RF CONTROL MODULE) – CONFIGURATION

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

1 2 3 Hold-Time

I • • • 5 secs

II • • o 30 secs

III • o • 1 min

IV • o o 5 min

V o • • 10 min

VI o • o 20 min

VII o o o 30 min

1 2 Light Levels

I • • Disabled

II • o 50 Lux

III o • 10 Lux

IV o o 2 Lux

1 2 Stand-by dimming level

I • • 10%

II • o 20%

III o • 30%

IV o o 50%

Hold-Time Daylight threshold Stand-by period Stand-by dimming level

Note:If enabled, when there is enough daylight, the fixture will remain OFF. The daylight threshold is disabled if the stand-by period is set to ‘forever’

Detection Area

1 2 Detection Area

I • • 100%

II • o 75%

III o • 50%

IV o o 10%

Factory Default Settings:Detection range: 100%Hold-time: 5 secsStand-by period: 10 secsStand-by dimming level: 10%Daylight sensor: Disabled

1 2 3 Stand-by time

I • • • 0 secs

II • • o 10 secs

III • o • 1 min

IV • o o 5 min

V o • • 10 min

VI o • o 30 min

VII o o • 1 hr

VIII o o o Forever

Page 17: LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE PART … · 1000 W HID. OCCUPIED (HIGH LIGHT LEVEL) UNOCCUPIED (CONFIGURABLE LIGHTLEVEL) RemPhos Technologies LLC • p 877.997.3674 •

OPTIONAL OCC SENSOR (HC428V/RF CONTROL MODULE) – CONFIGURATION (RF GROUPING)

01.17

RemPhos Technologies LLC • p 877.997.3674 • www.remphos.com 90 Holten Street • Danvers, MA USA • [email protected]

LEDBLOCK G3 HIGH POWER LED RETROFIT MODULE

RX1 RX2

Use a screwdriver to adjust the rotary switch on the transceivers. By keeping them pointed at the same channel grouping is automatically completed. A maximum of 16 groups are possible.

Note: A transceiver can receive signals from two different groups. This is achieved using the RX1 and RX2 rotary switches.