legend important notes - equipment planningmplusmedtech.com/123/pdf/11779.pdfarjohuntleigh jack...

12
Legend Light Sprinkler Vent Smoke detector Existing access trap Electrical outlet Access trap required (*) Exchanger Turntable Gate CURTAIN IV IV Wall bracket Wall post side Wall post "T" junction Curtain track IV track Bracket Joint bracket Motor/Charger location (*) (*) Symbol may vary depending of equipment type Swivel pole (*) DISTRIBUTOR : REPRESENTATIVE : DATE (DD-MMM-YYYY) : REFERENCE # : PAGE : INSTALLATION DRAWING 1. The ceiling minimum structure capacity must be able to support the load specified on the installation drawing. 2. Electrical power source outlet already available by the facility at a maximum distance of 3 meters from charging station. 3. Any obstructions such as vents, pipes, lights and sprinklers that could possibly be in the path of the ceiling lifts to be removed or relocated by the facility prior to installation. 4. Modifications of door headers by the facility. 5. Arjohuntleigh reserves the right to slightly modify the track layout if necessary. 6. See the "Agreed Conditions for the Installation of Ceiling Lifts" document included with this quote for important installation details. 7. Arjohuntleigh will not be held responsible for any damages, inconvenience, resulting from hitting any non visible conduits during our installation process. 8. Signed drawings are required prior to ordering and installation of ceiling lifts. This signature of each drawings confirms agreement of all the conditions listed above. IMPORTANT NOTES MY SIGNATURE BELOW VERIFIES THAT I HAVE: Reviewed all ____ pages, with a total quantity of ____ rooms, for the approbation of layout for each room and the approbation of structure for each room. I verify that the answers below are accurate to the best of my knowledge and I understand that the quote produced is dependent upon the conditions below as well as this full drawing set. x Is a load dock available? YES NO x Can facility accept shipment and store until install begins? YES NO x Will a drop trailer be needed? YES NO x Is parking available on site? Is there a fee involved? YES NO x Are there any installation time frame limitations? What are they? YES NO x Is a level of infectious control required? YES NO If YES, then what level ___________________________ CUSTOMER APPROVAL: DATE: REVISION(S) DATE(S) (D-M-Y) SHRINERS HOSPITAL FOR CHILDREN QC-513131MS 13-MAY-2013 ARJOHUNTLEIGH JACK SCHRADER 1 / 4 4 2 11779

Upload: truonganh

Post on 19-May-2018

218 views

Category:

Documents


2 download

TRANSCRIPT

Legend

Light

Sprinkler

Vent

Smoke detector

Existing access trap

Electrical outlet

Access trap required

(*)

Exchanger

Turntable

Gate

CURTAIN

IV IV

Wall bracket

Wall post side

Wall post

"T" junction

Curtain track

IV track

Bracket

Joint bracket

Motor/Charger location

(*)

(*) Symbol may vary depending of equipment type

Swivel pole

(*)

DISTRIBUTOR :

REPRESENTATIVE :

DATE (DD-MMM-YYYY) :

REFERENCE # : PAGE :

INSTALLATION DRAWING

1. The ceiling minimum structure capacity must be able to support the load specified

on the installation drawing.

2. Electrical power source outlet already available by the facility at a maximum

distance of 3 meters from charging station.

3. Any obstructions such as vents, pipes, lights and sprinklers that could possibly be

in the path of the ceiling lifts to be removed or relocated by the facility prior to

installation.

4. Modifications of door headers by the facility.

5. Arjohuntleigh reserves the right to slightly modify the track layout if necessary.

6. See the "Agreed Conditions for the Installation of Ceiling Lifts" document included

with this quote for important installation details.

7. Arjohuntleigh will not be held responsible for any damages, inconvenience,

resulting from hitting any non visible conduits during our installation process.

8. Signed drawings are required prior to ordering and installation of ceiling lifts. This

signature of each drawings confirms agreement of all the conditions listed above.

IMPORTANT NOTES

MY SIGNATURE BELOW VERIFIES THAT I HAVE:

Reviewed all ____ pages, with a total quantity of ____ rooms, for the

approbation of layout for each room and the approbation of structure for

each room. I verify that the answers below are accurate to the best of my

knowledge and I understand that the quote produced is dependent upon

the conditions below as well as this full drawing set.

Is a load dock available? YES NO

Can facility accept shipment and store until install begins? YES NO

Will a drop trailer be needed? YES NO

Is parking available on site? Is there a fee involved? YES NO

Are there any installation time frame limitations?

What are they? YES NO

Is a level of infectious control required? YES NO

If YES, then what level ___________________________

CUSTOMER

APPROVAL: DATE:

REVISION(S) DATE(S) (D-M-Y)

SHRINERS HOSPITAL

FOR CHILDREN

QC-513131MS

13-MAY-2013

ARJOHUNTLEIGH

JACK SCHRADER

1 / 4

4

2

11779

NEC

Service

158 "H90

158 "H90

115 " O

AL H

140 E

CS

THE EXACT LOCATION OF THE LIFT SYSTEM IS TO BE DETERMINED ON SITE.

LISTING OF ROOM NUMBER(S):

- ALL HARDWARE INCLUDED.

(ACCORDING TO STRUCTURE)

QUANTITY OF ROOMS:

DRAWN BY :

REFERENCE # : PAGE :

SCALE :

DATE CREATED (DD-MMM-YYYY) :

SAFE WORKING LOAD BELOW LIFT:

MINIMUM STRUCTURE CAPACITY:

SHRINERS HOSPITAL

FOR CHILDREN

QC-513131MS

13-MAY-2013

usaddsom02 1/4" = 1'

2 / 4

2

600LBS [272KG]

750LBS [340KG]

THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY

G

TILE

CT 24,CT25

A=120"

B=72"

F=16"

G=53"

H=6"

ECS INSTALLATION

MS2 2F ECS MOTOR

11779

- ALL HARDWARE INCLUDED.

(ACCORDING TO STRUCTURE)

QUANTITY OF ROOMS:

DRAWN BY :

REFERENCE # : PAGE :

SCALE :

DATE CREATED (DD-MMM-YYYY) :

SAFE WORKING LOAD BELOW LIFT:

MINIMUM STRUCTURE CAPACITY:

SHRINERS HOSPITAL

FOR CHILDREN

QC-513131MS

13-MAY-2013

usaddsom02 N/A

3 / 4

0

600LBS [272KG]

750LBS [340KG]

STRUT BRIDGE (SLOT FACE DOWN)

FOR "G" UP TOUSE UNISTRUT

1'-8"

2'-0"

3'-3"

4'-0"

5'-4"

6'-4"

8'-6"

10'-4"

HS 158-12

P1000

HS 2716-12

P5500

P1001

P5000

P5501

P5001

FINISH

CEILING

G

BRACE

"NOTE: ARJOHUNTLEIGH GUARANTEES THE STRUCTURAL INTEGRITY OF THE TOTAL LIFT SYSTEM DESIGN, INCLUDING TRACK,

BRACING, HANGERS, AND ALL CONNECTIONS TO THE BUILDING STRUCTURE. OUR DESIGN IS BASED ON THE REQUIREMENTS

OF THE CURRENT INTERNATIONAL BUILDING CODE (IBC) AND THE SESMIC LOADS OF THE REGION. THE FACILITY MUST VERIFY

THE ADEQUACY OF THE BUILDING STRUCTURE TO SUPPORT THE LOADS IMPOSED BY THE LIFT SYSTEM."

I BEAM

2

8

10

7

5

15

14

1

6

4

PLACE DROP WITHIN

6" OF CENTERLINE OF

STRUT

LIFT CAPACITY= 600 LBS

LIFT TRACK BY

ARJOHUNTLEIGH

2

1

2

" MAX. DISTANCE

BETWEEN ANGLE

FITTING AND CEILING

11

12

13

8

9

3

1 6 8714

10

8

6

2

4

BRACE

10

Item # Part # Description Qty

1

2 000.00394 THREADED ROD 3/8-16 X 10' ZINC 1

3 000.00402 LOCKNUT STOVER 3/8-16 ZINC 1

4 000.00405 NUT 3/8-16 ZINC 3

5 000.00424 HILTI STRUT SADDLE NUT 3/8-16 1

8 000.04430 FLAT WASHER M10 ZINC 6

200.11140 CEILING PLATE ø100MM 2

200.11170 BRACKET SHIM 12mm 1

10

000.00357 BOLT 3/8" - 16 X 1" 3

11

700.11100 TRACK BRACKET KWIKTRAK 1

9

P27XX UNISTRUT BEAM CLAMP 4

12

P1068 UNISTRUT ANGLE 2

6

000.04875 FLAT WASHER M12 5

13

000.00425 LOCKWASHER 3/8" 4

(PENDING ON STRUT USAGE)

000.04435 TAB WASHER M10 1

14

7000.00426 HILTI CHANNEL NUT 3/8-16 3

15

11779

- ALL HARDWARE INCLUDED.

(ACCORDING TO STRUCTURE)

QUANTITY OF ROOMS:

DRAWN BY :

REFERENCE # : PAGE :

SCALE :

DATE CREATED (DD-MMM-YYYY) :

SAFE WORKING LOAD BELOW LIFT:

MINIMUM STRUCTURE CAPACITY:

SHRINERS HOSPITAL

FOR CHILDREN

QC-513131MS

13-MAY-2013

usaddsom02 N/A

4 / 4

0

600LBS [272KG]

750LBS [340KG]

LATERAL BRACE REQUIREMENTS REV-3

LEGEND

LATERAL

BRACE

TRACK

BRACKET

TRACK

BRACKET JOINT

LATERAL BRACE

LATERAL BRACE

LATERAL BRACE

FLAT WASHER M10

000.04430

LAG BOLT 3/8 X 2"

000.00699

UNISTRUT

000.0XXXX

SADDLE NUT

000.00424

FLAT WASHER M12

000.04875

4

5

°

FLAT WASHER M10

000.04430

LOCK WASHER 3/8

000.00425

BOLT 3/8-16 X 1"

000.00357

4 TRACKS SECTION

3 TRACK BRACKETS JOINT

9 LATERAL BRACES

1 TRACK SECTION

0 TRACK BRACKET JOINT

3 LATERAL BRACES

2 TRACKS SECTION

1 TRACK BRACKET JOINT

4 LATERAL BRACES

3 TRACKS SECTION

2 TRACK BRACKETS JOINT

6 LATERAL BRACES

- MINIMUM 3 LATERAL BRACES.

- NUMBER OF LATERAL BRACE = (NUMBER OF TRACK BRACKET JOINT X 2) + 2.

WOOD JOIST STEEL CONCRETE

HOLLOW CORE

ACCEPTABLE ANGLE

POSSIBLE ANCHOR LATERAL TO THE CEILING OR TO THE WALL

HILTI KHEZ 3/8 X 3 1/2

418058

LATERAL BRACE

HIT S SCREEN TUBE

00068613

HY150 MAX ADHESIVE

332230

3/8" HIT A ROD

00088978

FLAT WASHER M12

000.04875

FLAT WASHER M10

000.04430

NUT 3/8-16 ZINC

000.00405 11779

Maxi sky600

The complete, customisedceiling lift system

…with people in mind11779

2 |

a TOTaL CEiLiNG LiFT CONCEPT

Maxi Sky600 is a ceiling lift system that enables patients and residents to be transferred in a comfortable and dignified way. For the carer, it offers an easy-to-operate system that eliminates manual lifting.

a single carer can perform transfers quickly and efficiently, controlling all procedures with the handset. Maxi Sky600 saves time, because it is always available for duty and within easy reach for the carer. and, when it’s not in use, the unit takes up no precious floor space as it is discreetly out of sight at the recharging station on the overhead track.

What makes Maxi Sky600 unique among ceiling lifts? it is a total concept. arjoHuntleigh does much more than delivering an advanced ceiling lift, offering complete support every step of the way from track design to long-term system servicing.

Maxi Sky600

11779

| 3 Maxi Sky600

Maxi Sky600 has a discreet, aesthetic design that blends in well with the care environment.

• Designing the best system for your facility We will help you create a layout that provides ideal coverage using our revolutionary modular track.

• Faster installation Track installation is a quicker and easier process due to a new patented bracket design.

• On track The tight radius of the curved track sections enables layouts with superior space utilisation. Track sections fit together using a unique pin-locking system, and once in place, the seamless joints provide a smooth ride for the resident during lateral movement.

• Instant availability The lift is always ready for use. after transfers, the lift can be programmed to return to the clip-on charging station, which can be positioned anywhere on the track.

• Smooth operation and control Regulation of lateral speed and spreader bar height is programmable from the handset. Electronic soft-start/soft-stop enables the lift to be stopped smoothly and safely in the required position.

• Simple maintenance Battery changing is easy and requires only a screwdriver. a red light on the lift alerts the carer when servicing is required.

• The widest range of accessories access to our patient interface solutions – clip slings, loop slings, spreader bars and stretcher frame – gives you unrivalled flexibility to adapt to different needs.

• Provision of staff training We not only provide thorough guidance on how to use the system correctly, but also offer training on ergonomic working techniques.

• Long-term system support arjoHuntleigh technical staff ensure that regular servicing and any unforeseen problems are dealt with quickly and efficiently.

11779

4 |

aCCEssORiEs FOR OPTiMisED CaRE

Maxi Sky600

arjoHuntleigh slings are colour-coded to clearly indicate sizes.

The 4-point Powered DPs spreader bar.

Patient interface solutions are the key to optimising care for individuals. The comprehensive range of Maxi Sky600 accessories gives facilities flexibility to provide ideal solutions for different residents’ requirements and to respond to changing needs. Sling solutions

a complete range of arjoHuntleigh loop and clip slings covers the needs of all care facilities. Clip slings include standard padded and unpadded slings, special purpose slings for toileting, mesh slings for bathing and showering, and solutions for single and double amputees. The broad spectrum of sizes and sling types means that the ceiling lift can always be used with a sling that is optimised for the resident’s comfort and safety.

Spreader barsarjoHuntleigh loop and clip slings fit applicable 2-point spreader bars or 4-point DPs (Dynamic Positioning system) spreader bars. The DPs provides a safe and comfortable sling position for the patient during transfers and makes repositioning tasks easier for the carer. Powered DPs enhances DPs benefits by providing powered assistance to improve the precision and ease of resident repositioning. Using Powered DPs enables effortless, exact positioning of the resident at the press of a button.

11779

| 5

Walking Jacket Compatibility with the arjoHuntleigh Walking Jacket means Maxi Sky600 can also be used as an aid in rehabilitation. The Walking Jacket, which is applied to a 2-point loop spreader bar, provides safe and stable support during walking and stepping exercises.

Stretcher frameMaxi Sky600 is compatible with different stretcher solutions and is suitable for a number of types such as the scoop stretcher.

Quick Connect at facilities where there is a regular need to switch between various spreader bars or to a stretcher, the Quick Connect accessory can provide a smooth, fast solution for changeovers.

Electronic scale The optional Class 3-approved electronic scale allows residents to be weighed easily and efficiently during transfers.

The 4-point Flat DPs spreader bar, favourable e.g. low ceiling clearance.

Class 3-approved scale, used here on a 2-point spreader bar.

Maxi Sky600

11779

6 |

The exchanger and turntable enable a variety of different track solutions.

a turntable provides a choice of directions outside the resident’s room.

The exchanger is powered by the lift

cassette of Maxi Sky600 to facilitate track

switching. This solution means no extra power

supply needs to be installed.

Maxi Sky600 can continue on a different track after passing the

exchanger.

Two, three or four tracks can be

connected at various angles to the turntable, which is also powered

by Maxi Sky600.

The gate, powered by Maxi Sky600, is a smooth way to

combine a fixed track and an x-y (traverse)

system.

a FLExiBLE MODULaR TRaCk sysTEM

Maxi Sky600

11779

Maxi sky iN CaRE siTUaTiONs

if a resident has fallen, the long lifting strap (2.3 m) makes it easy and safe to perform a lift from the floor.

When full-room coverage is required, the x-y (traverse) system is an ideal choice. With the unique traverse action, the track moves very easily with no risk of jamming. Here, it is used with an arjoHuntleigh curtain to provide a high degree of privacy.

The track can be partially concealed in a suspended ceiling to provide a discreet solution.

There is a full range of Maxi Sky ceiling lifts that includes a portable lift, Maxi Sky440, with a safe working load of 200 kg (440 lbs) and, pictured here, Maxi Sky1000, which is designed to handle bariatric patients, and has a safe working load of 455 kg (1000 lbs).

| 7 Maxi Sky600

11779

55" (1400 mm)

126" (3200 mm)

118

" (3

000

mm

)

31"

(800

mm

)

8" (2

00 m

m)

24" 31" (800 mm)

(600 mm)

DA B C E

Prin

tedinth

eCzech

rep

ublic•Point•01.LD

.02.1.GB-INT.1.AH•April20

08

Product information

Safe working load 272 kg (600 lbs.)

Unit weight (batteries included) 11.5 kg (28 lbs.)

Length 400 mm (15 ¾")

Width 256 mm (10 ¹⁄8")

Height 188 mm (7 3⁄8")

LED indicator when maintenance is required

Electronic microprocessor soft-start and stop motor control

Double centrifugal emergency brake system

Manual emergency lowering device (located on the motor cab)

Electrical up and down emergency buttons

Emergency stopping device (pull cord) accessible from the ground

Strap length up to 2.3 meter (90")

Lifting speed: 2.7 cm/sec. (1.2" / sec.) at 272 kg (600 lbs.) 3.5 cm/sec. (1.6" / sec.) at 200 kg (440 lbs.) 6 cm/sec. (2.3" / sec.) at 0 kg (0 lbs.)

Batteries: 2x5 Ah will average 150 cycles (loaded at 75 kg / 165 lbs.)

Adjustable horizontal displacement speeds: 10, 15, 20, 25 cm/sec. (4, 6, 8, 10" / sec.). Preset at 20 cm/sec (8" / sec.)

User initiated return to charge station function with weight sensor cut-out of 9kg (20 lbs.) on/off programmable

ABS FR casing (fire retardant)

Charger unit 100-240 Vac / 50-60 Hz / 27 Va

Clip on charger anywhere on the track

Class 2 insulated

Hand control Santopren tactile buttons / IP44

Infrared remote control (optional)

Approvals CSA No 601.1, UL No 2601-1 certifications CE marked / ISO 10535

Only ArjoHuntleigh designed parts, which are designed specifically for the purpose, should be used on the equipment and products supplied by ArjoHuntleigh. As our policy is one of continuous development we reserve the right to modify designs and specifications without prior notice.

ArjoHuntleigh, Maxi Sky, Walking Jacket and Mobility Gallery™ are trademarks belonging to the ArjoHuntleigh group.© Arjo AB, 2008

The Maxi Sky600 is part of the complete arjoHuntleigh Maxi Sky ceiling lift range that includes the 1000 model, a bariatric ceiling lift, and the 440 model, a portable ceiling lift.

Mobility Gallery™

D Doris, who has no capacity to support herself

E Emma, who is almost completely bedridden and totally dependant Please contact arjoHuntleigh for further information on the Mobility Gallery™.

Suitable for Doris and Emma

Space requirement

PrODuCT SPECIFICATIOnS

Blue area shows the minimum working area required for the staff to be able to use the mechanical aids in an ergonomic way from one side.

Light blue area shows required extension of working area to facilitate activities from either side to provide adequate access for the resident, mechanical aid and assisting carer .

3200 mm (126”)(24”)

3000

mm

(118

”)

600 mm 800 mm (31”) 1400 mm (55”)

800

mm

(31”

)

200

mm

(8”)

Arjo International ABPO Box 61SE-241 21 ESLÖVPhone: +46 413 645 00Fax: +46 413 645 63

www.ArjoHuntleigh.com

…with people in mind

MEMBEr OF THE GETInGE GrOuP11779