LENS DYNAMICS, INC.
![Page 2: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/2.jpg)
SCLERAL HISTORY
• Original contact lens
• Hand ground glass lenses
• Fit by casting a mold of the cornea
![Page 3: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/3.jpg)
EARLY SCLERAL PERFORMANCE
• Difficult to fit
• Hard to manufacture and reproduce
• Corneal hypoxia
• Very short wearing times
• Corneal molding – The negative kind
![Page 4: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/4.jpg)
SCLERAL DEFINED
• Mini-Sclerals – 12.5mm to 14.5mm
• Medium Range Sclerals – 15.0mm to 18.0mm
• Full Sclerals – 18.5mm to 28.0mm
![Page 5: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/5.jpg)
SCLERALS – FIRST OR LAST RESORT?
![Page 6: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/6.jpg)
WHY FIT A SCLERAL LENS?
THE PRO:
• To vault highly irregular corneas
• To provide better visual acuity than soft lenses
• To prevent lost lenses
• New Oxygen permeable materials
![Page 7: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/7.jpg)
WHY FIT A SCLERAL LENS?
THE CON:
• Harder to fit
• Harder to insert and remove
• Can reduce metabolic waste removal
• Potential for hypoxia
• Harder to fit
![Page 8: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/8.jpg)
THE PRACTICAL:
• First or Last Resort as a design?
• Who fits sclerals at all?
• Who fits sclerals as the design of First choice?
• Who fits sclerals as a design of Last resort?
![Page 9: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/9.jpg)
THE DESIGN:
• 13.0mm, 13.5mm, 14.0mm
• Lathe cut on DAC ALM lathes
• Spherical back and front surfaces
• Normally NOT fenestrated
![Page 10: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/10.jpg)
HOW TO FIT
• Start with a base curve close to average Ks
• Trial for best alignment pattern as possible
• Be sure there is NO conjunctival drag
• Do spherical over-refraction
• Need 0.5mm of movement
![Page 11: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/11.jpg)
FITTING TIPS
• Fill concave side with saline/wetting drops into posterior of trial lens
• Dip fluorescein strip into solution
• Insert using 2 fingers to handle the trial lens with patient looking at floor
• Low riding lens – select flatter base curve
• Flatten base curve to solve edge tightening
![Page 12: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/12.jpg)
CASE HISTORIES
![Page 13: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/13.jpg)
48 years old, Caucasian male, OD cornea
• Can’t use bi-toric• Quadrant Specific
base curve not indicated
• Temporal/superior area eliminates reverse curve design
• Select Semi-Scleral 13.5 design
CASE 1
![Page 14: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/14.jpg)
48 years old, Caucasian male, OD cornea
• Average K is 47.00 D. or 7.18mm
• Select 7.20mm BC from trial set, 13.5mm -4.00
• Acceptable fit with -2.25 over-refraction
CASE 1
![Page 15: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/15.jpg)
22 years old, African American male, OS cornea
CASE 2
• Superior, peripheral area too steep for Quadrant Specific base curve
• Bi-toric not indicated• Select Semi-Scleral
13.5 design
![Page 16: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/16.jpg)
22 years old, African American male, OS cornea
• Average K is 47.00 D. or 7.18mm
• Select 7.20 BC from trial set, 13.5mm
• Lens too tight at edge and too much vaulting
CASE 2
![Page 17: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/17.jpg)
22 years old, African American male, OS cornea
• Select trial lens 0.2mm flatter or 7.40mm
• Acceptable fit• Perform spherical
over-refraction
CASE 2
![Page 18: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/18.jpg)
31 year old Caucasion female, OD cornea
• Bi-toric not indicated• Flatter areas too
narrow for Quadrant Specific base curves
• Reverse curve design not indicated
• Select Semi-Scleral 13.5 design
CASE 3
![Page 19: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/19.jpg)
31 year old Caucasion female, OD cornea
• Average K is 46.25 D. or 7.30mm
• Select 7.30mm trial lens from trial set
• Low riding lens-select flatter base curve
CASE 3
![Page 20: LENS DYNAMICS, INC.. SCLERAL HISTORY Original contact lens Hand ground glass lenses Fit by casting a mold of the cornea](https://reader036.vdocument.in/reader036/viewer/2022062517/56649e875503460f94b8acc9/html5/thumbnails/20.jpg)
31 year old Caucasion female, OD cornea
• Select 7.50mm base curve from trial set
• Acceptable fit with lens properly positioned
• Perform spherical over-refraction
CASE 3