Sonic Intelligence is a registered trademark of Siemens Milltronics Process InstrumentsInc. This publication is a guide only. Models available and product specifications aresubject to change without notice. For detailed specifications and a full list of approvals
(Intrinsically Safe, Explosion Proof, Non-Sparking Equipment, Hazardous Locations, andSanitary), see www.siemens.com/level. Siemens Milltronics Process Instruments Inc. 2005.
Reliablelevel measurement
Its reliable. Thats what customers say about SiemensMilltronics technology installed in hundreds of thousandsof industrial process applications worldwide.
Siemens Milltronics is the global center for levelmeasurement technology within Siemens ProcessInstrumentation. You can rely on our instruments forhigh performance: they provide cost-effectivemeasurement of continuous level, point level, andinterface in a wide range of applications, such aswater and wastewater, chemical, petrochemical,pharmaceutical, mining, cement, aggregates,and bulk solids.
This guide provides an overview of level measurementinstruments to help you select the equipment andsolution that best meet your needs.
For the latest product information or to find a representativenear you, visit our web site at www.siemens.com/level
2
Contents Page
Electro-mechanical point level switches 4
Frequency shift level switches 5
Frequency shift level measurement 6-7
Radar level measurement 8-9
Ultrasonic level measurement 10-11
Basic ultrasonic level measurement 12
Hydrostatic level 13
Communications solutions 14-15
million
in one
Level measurement courses at theSiemens Milltronics Learning Center
Siemens Milltronics ProcessInstruments offers world-classlevel instrumentation trainingat our state-of-the-art learningcenter in Peterborough,Canada. For current infor-mation and schedules, contactus by phone at 1-705-740-7650or visit our website at
Million in one
Signal processing with fieldexperienceSiemens level measurement instruments come withextensive field experience. Siemens Milltronicsdeveloped the signal processing technology for levelinstruments based on the experience of a millioninstruments in industrial applications.
With this experience, we understand the importance
of reliability, and we know what it takes to make atrusted and accurate level instrument for demandingapplications. Thats why our engineers invented SonicIntelligence and Auto False-Echo Processing, andthats why these instruments carry so many patents.With Siemens Milltronics you get the experience of amillion applications in one instrument.
Sonic IntelligenceOur patented Sonic Intelligence signal processingtechnology was developed using knowledge providedby our field service engineers from real applicationdata. Siemens Milltronics instruments offer the unique
advantage of this technology. Sonic Intelligencedifferentiates between true echoes from the materialand false echoes from obstructions or electrical noise.The sophisticated software is continuously updatedand supported by field data gained from more than500,000 ultrasonic and radar level applications. Thisin-depth knowledge and experience is built into thesoftwares advanced algorithms to provide intelligentprocessing of echo profiles. The result is repeatable,fast, and reliable measurement you can trust.
www.siemens.com/instrumentation/training/canada
-
8/6/2019 Level Guide En
3/16
SITRANS Probe LR2-wire, 5.8 Ghz (6.3 in NorthAmerica) radar transmitter forlevel/volume monitoring of liquidsand slurries in storage and processvessels
Range
Key features
Output
Communications
Powerspecifications
Approvals
Processtemperature
Processpressure
20 m (65 ft)
4 to 20 mA, 24 V DC nominal withmax. 550 Ohm, 30 V DC maximum
-40 to 80 C (-40 to 176 F)
Up to 3 bar (43.5 psi g)
High signal-to-noise ratio Sonic Intelligence Echo Processing Auto False-Echo Suppression Level, volume and flow
measurement
Infrared Intrinsically Safe (IS)handheld programmer
Built-in temperature compensation Choice of threaded connections ETFE or PVDF copolymer
transducer Rotating head aligns with conduit
for easy wiring
4 to 20 mA Intrinsically safe
HART
SIMATIC PDM for remoteconfiguration and diagnostics
CE, CSAUS/C, FM, ATEX, Lloyds Registerof Shipping, ABS, Industry Canada,
FCC, R&TTE
SITRANS Probe LU2-wire, loop powered ultrasonictransmitter for level/volume/flowmonitoring of liquids in storagevessels, simple process vessels, andopen channels
6 m (20 ft) or 12 m (40 ft)
HART: nominal 24 V DC withmax. 550 Ohm, 30 V DCmaximum, 4 to 20 mAPROFIBUS: bus-powered, as perIEC 61158-2; 12, 13, 15 or20 mA depending on programming(General Purpose or IntrinsicallySafe version)
-40 to 85 C (-40 to 185 F)
0.5 bar (7.25 psi g)
High signal-to-noise ratio,comparable to a 4-wire device
Sonic Intelligence Echo Processing Auto False-Echo Suppression Level and volume measurement 5.8 GHz (USA 6.3 GHz) Infrared Intrinsically Safe (IS)
handheld programmer Patented, shielded and hermetically
sealed polypropylene
antenna/process connection;100 mm (4") shield standard
Rotating head aligns with conduitfor easy wiring
Options: 250 mm (10") shield length
4 to 20 mA Intrinsically safe
HART or Profibus PA SIMATIC PDM for remote
configuration and diagnostics
CE, CSAUS/C, FM, ATEX, LloydsRegister of Shipping, ABS
SITRANS Probe2-wire ultrasonic and radar leveltransmitters
SITRANS Probe LU and SITRANS Probe LRset the new standard for ultrasonic andradar continuous level measurement.These transmitters offer you superiorreliability for level, volume, and flowapplications in the water and waste-water, food, chemical, and hydrocarbonprocessing industries.
SITRANS Probe is the award-winningMilltronics The Probe taken to ahigher level with innovative transducerand antenna designs, communications
capability, and nineteen patents.The result is greater accuracy andreliability for your continuous levelmeasurement applications.
SITRANS Probe LU ultrasonic levelmeasurement transmitter sets thestandard for precision with an accuracyof 0.15%. The improved signal-to-noiseratio enhances Sonic Intelligenceecho processing and Auto False-EchoSuppression to support the 0.15%accuracy and, as a result, guaranteesreliability.
www.siemens.com/probelu
3
SITRANS Probe
HART is a registered trademark of HART Communication Foundation. SIMATIC and SITRANS areregistered trademarks of Siemens AG. Milltronics is a registered trademark of Siemens MilltronicsProcess Instruments Inc.
-
8/6/2019 Level Guide En
4/16
Electro-mechanical point level switches
Range
Process pressure*
Key features
Communications
Power specifications
Approvals
Process temperature
SITRANS LPS200
Electro-mechanical rotary paddleswitch for level detection ofpowder and granular solids withbulk densities as low as 35 g/l(2.19 lb/ft3)
10 m (30 ft) 4 m (13 ft)
Up to 0.5 bar (7.25 psi) Up to 10 bar (145 psi) optional
Up to 10 bar (145 psi)
High or low level alarm Densities as low as 100 g/l
(6.25 lb/ft3) standard
Hinged paddle for densities as lowas 35 g/l (2.19 lb/ft3)
Switch selectable power supply Rotatable enclosure Unique friction clutch mechanism Installation through process
connection 114" NPT or BSP Compact, extended models and
cable extension up to 10 m (30 ft) High temperature model High pressure model
Microswitch SPDT contact,5A at 250 V AC, non-inductive
SPDT relay, 8A at 250 V AC,non-inductive
CE, CSA, FM,ATEX (dust ignition approvals)
CE, CSA, FM,ATEX (dust ignition approvals)
SITRANS LVS200
Electro-mechanical vibratoryswitch for level detection ofpowder and granular solids withbulk densities as low as 20 g/l(1.3 lb/ ft3)
-20 to 80 C (-4 to 176 F) -20 to 220 C (-4 to 428 F)
HT model
-40 to 150 C (-13 to 302 F)
Jumper selectable 115 V AC, 15%, 50/60 Hz, 4 VA
230 V AC, 15%, 50 Hz, 6 VA24 V DC, 15%, 2.5W
19 to 230 V AC, +10%, 50/60 Hz,8 VA19 to 55 V DC, +10%, 1.5W
Electro-mechanicalswitches are rotating orvibrating point levelswitches for a cost-effectivesolution for basic
applications on powders,grains, and other dry solids.
Output
Switch changes state atapproximately 17 from vertical
Single N.C. contact5 Ohm max., 2A at 24 V DC
CE
MilltronicsTilt SwitchElectro-mechanical tilt switch forpoint level detection, plug chutedetection, belt tracking and feedloss detection on conveyor belts
Low temperature:-40 to 90 C (-40 to 194 F)
High temperature:-40 to 150 C (-40 to 302 F)
30 V DC (max.)
High or low level alarm Compact design Top, side, angle mount
Rotatable enclosure Self-cleaning fork Extended model up to 4 m (13 ft) Interface model (solids in liquids) Remote electronics option with
pipe extended model
* Pressure ratings are in bar (psi) gauge, relative
Not rated
High or low alarm 304 stainless steel Total encapsulated mercury switch
Easy installation and operation
Optional probe extensions: Flat and cross paddles Anti-wear Float
4
-
8/6/2019 Level Guide En
5/16
100 mm (4")
Up to 10 bar (145 psi)
Inverse frequency technology Sensitivity adjustment
Options: Intrinsically Safe Dust-ignition proof Non-hazardous general purpose SensGuard for abrasive
applications PPS or PVDF probes IP68
4 to 20/20 to 4 mA 2-wirecurrent loop
Solid-state or relay switch
Relay output (all syntheticversion)
CE, CSA, FM, ATEXLloyds Register of Shipping,ABS, WHG
Pointek CLS 100Compact 2-wire inverse frequencyshift capacitance switch for leveldetection in constricted spaces,interfaces, solids, liquids, slurries,and foam
Rod: 1 m (40")
Up to 50 bar (725 psi) Up to 525 bar (7665 psi)
HP version
Patented Active-Shieldtechnology
Integrated local display
2-wire loop signal Push-button calibration Full-function diagnostics
Options:
One-point calibration in % High temperature (HT version) High pressure (HP version)
4 to 20/20 to 4 mA 2-wirecurrent loop
Solid-state switch
HART SIMATIC PDM compatible
Pointek CLS 200Inverse frequency shift capacitanceswitch with a high level of chemicalresistance; ideal for level detectionof interfaces, solids, liquids, slurries,and foam, and for simple pumpcontrol
Pointek CLS 300Inverse frequency shift capacitancelevel switch for detecting interfaces,solids, liquids, slurries and viscousmaterials in demanding conditionsof low/high pressure, high temp-eratures, and corrosive andabrasive materials
Pointek CLS 500Inverse frequency shift capacitancepoint level switch for detectinginterfaces, solids, liquids, slurriesand viscous materials in criticalconditions of extreme temp-erature and extreme pressure
Up to 35 bar (508 psi)
Patented Active-Shield technology Universal transmitter Multiple outputs
5 dipswitches for specialadjustments e.g. fail safe,high/low
Options: Extensions up to 25 m (82 ft) Thermal isolator High temperature (HT version)
Analog model: 1 form C (SPDT) relay Solid-state switch
Digital model: Solid-state switch Relay or mA output
-40 to 200 C (-40 to 392 F) -40 to 400 C (-40 to 752 F)
HT version
Rod: 1 m (40")Cable: 25 m (82 ft)
-40 to 100 C (-40 to 212 F) -40 to 125 C (-40 to 257 F) -40 to 200 C (-40 to 392 F) Up to 400 C (752F)
HT version
Rod: 5.5 m (18 ft)Cable: up to 35 m (115 ft)
Inverse frequency technology Level detection independent of
tank wall/pipe
High/low gain switch Suitable for hazardous areas Multiple outputs Fully adjustable hysteresis
Options:
Rigid, cable and sanitary SensGuard for abrasive
applications Thermal isolator Non-hazardous general purpose
Analog model:
1 form C (SPDT) relay Solid-state switch
Digital model: Solid-state switch Relay or mA output
CE, CSANRTL/C, FM, ATEXLloyds Register of Shipping, ABS,WHG, Bureau Veritas, currentsignaling according to NAMUR NE 43
CE, CSA, FM, ATEX, 3ALloyds Register of Shipping,ABS, WHG
CE, CSA, FM, ATEXLloyds Register of Shipping,ABS, WHG
Standard: 10 to 33 V DC Intrinsically Safe: 10 to 30 V DC
12 to 250 V AC/DC, 50/60 Hz,2VA/2W max.
12 to 250 V AC/DC, 50/60 Hz,2VA/2W max.
12 to 33 V DC, (30 V DC for IS)at 3.6 mA, 9.5 to 33 V DC,(30 V DC for IS) at 22 mA
3.6 to 22 mA/22 to 3.6 mA(2-wire current loop)
Up to 25 bar (365 psi) Up to 10 bar (145 psi)
cable version
Pointek is a registered trademark of Siemens Milltronics Process Instruments Inc.
Frequency shift level switches
Digital model: PROFIBUS PA Analog model: 3 LED indicators
Digital model: PROFIBUS PA Analog model: 3 LED indicators
5
-
8/6/2019 Level Guide En
6/16
Frequency shift level measurement
* Pressure ratings are in bar (psi) gauge, relative
Range
Process pressure*
Key features
Output
Power specifications
Communications
Approvals
Process temperature
Fitting length: 55 mm (2.1")
Up to 50 bar (725 psi)Option:Up to 200 bar (2920 psi)
Flange and sandwich mounting,according to ANSI and DINstandards
Integrated local display Full-function diagnostics Stainless steel AISI 316L process
connection
Options:Process connections:Carbon steel C35
4 to 20/20 to 4 mA2-wire current loop
Solid-state switch
SITRANS PD 500Inverse frequency shift capacitance2-wire switch for interface andproduct presence detection, evenin extreme and critical processconditions; suitable for use on anyferrous or non-ferrous piping system
-40 to 200 C (-40 to 392 F)optional: up to 400 C (752 F)
down to -200 C (-328 F)
CE, FM/CSA, FM, ATEXLloyds Register of Shippingcurrent signaling according toNAMUR NE 43
12 to 33 V DC, (30 V DC for IS)at 3.6 mA, 9.5 to 33 V DC,(30 V DC for IS) at 22 mA
3.6 to 22 mA/22 to 3.6 mA(2-wire current loop)
HART SIMATIC PDM compatible
SITRANS LC 300Inverse frequency shift capacitancelevel transmitter for liquids andsolids, high accuracy applicationssuch as food and beverages, petfood and bulk solids; ideal forchallenging processes involvingvapor and dust
SITRANS LC 500Inverse frequency shift capacitancelevel and interface transmitter forextreme and critical processconditions, such as oil and liquidgas, toxic and aggressive chemicalsand vapors
-40 to 200 C (-40 to 392 F) -40 to 200 C (-40 to 392 F)optional: up to 400 C (752 F)
down to -200 C (-328 F)
Up to 35 bar (511 psi) Up to 200 bar (2920 psi)Option:Up to 525 bar (7665 psi)
Rod: 5.0 m (16.4 ft)Cable: 25 m (82 ft)
Rod: 5.5 m (18 ft)Cable: 35 m (115 ft)
Push-button calibration Patented Active-Shield
technology
Integrated local display
Pre-detection alarm Pump control Patented Active-Shield technology Push-button calibration One-point calibration Integrated local display Full-function diagnostics
Options: High temperature High pressure Sanitary Customized application design Process connections and
sensor options Custom materials
4 to 20/20 to 4 mA2-wire current loop
4 to 20/20 to 4 mA2-wire current loop
Solid-state switch
HART
CE, CSANRTL/C, FM, ATEXLloyds Register of Shipping, ABS,3A, Bureau Veritas, current signalingaccording to NAMUR NE 43
CE, CSANRTL/C, FM, ATEXLloyds Register of Shipping, ABS,Bureau Veritas, current signalingaccording to NAMUR NE 43
9-32 V DC any polarity, 2-wirecurrent loop circuit (9 V at 22 mA)
12 to 33 V DC, (30 V DC for IS) at3.6 mA, 9.5 to 33 V DC,(30 V DC for IS) at 22 mA
3.6 to 22 mA/22 to 3.6 mA(2-wire current loop)
6
-
8/6/2019 Level Guide En
7/16
-
8/6/2019 Level Guide En
8/16
* Pressure ratings are in bar (psi) gauge, relative. Modbus is a registered trademark of Schneider Electric.
SITRANS LR 300Pulse radar level instrument forliquids and slurries in processvessels and extreme or hazardousprocess conditions
SITRANS LR 4004-wire FMCW radar leveltransmitter for high power andlong range measurement of solidsand liquids; ideal for extreme dustor low dielectric liquids
Universal AC/DC 48 to 230 V AC, 15%,
40 to 70 Hz, 28 VA/11W 24 to 230 V DC, 15%, 9W
120 to 230 V AC, 15%,50/60 Hz,12 VA/6W
24 V DC, +25/-20%, 6W(optional)
-40 to 200 C (-40 to 392 F) -40 to 200 C (-40 to 392 F)optional: up to 250 C (482 F)
Up to 40 bar (580 psi) processconnection type dependent
Up to 40 bar (580 psi) processconnection type dependent
20 m (66 ft) 50 m (164 ft)
Level, space, distance andvolume measurement
Infrared Intrinsically Safehandheld programmer
Auto False-Echo Suppression 5.8 GHz (USA 6.3 GHz)
Options: Stainless steel enclosure Sanitary Purging (self-cleaning) Process connections and antenna
options (see page 9)
Level and volumemeasurement
Infrared Intrinsically Safehandheld programmer
Auto False-Echo Suppression Self-calibration with internal
reference 24 GHz FMCW and high signal-
to-noise ratio
Options: High temperature extension Purging (self-cleaning)
(liquids version)
4 to 20 mA 4 to 20 mA 1 Relay
Modbus ASCII/RTU HART SIMATIC PDM for configuration
and diagnostics
Option:PROFIBUS PA
HART or PROFIBUS PA SIMATIC PDM for configuration
and diagnostics
CE, CSANRTL/C, FM, ATEX,Lloyds Register of Shipping,ABS Type Approval, 3A,Industry Canada, FCC, R&TTE
SITRANS LR 2002-wire loop-powered pulse radarlevel transmitter for liquid bulkstorage or simple process vessels
4 to 20 mA loop, 24 V DC nominal,30 V DC max.Minimum voltage depends on totalloop resistance
-40 to 200 C (-40 to 392 F)
Up to 40 bar (580 psi) processconnection type dependent
20 m (66 ft)
Level, space, distance andvolume measurement
Infrared Intrinsically Safehandheld programmer
Auto False-Echo Suppression andSonic Intelligence
5.8 GHz (USA 6.3 GHz) Patented, shielded and
hermetically sealed polypropyleneantenna/process connection;100 mm (4") shield standard
Options:
250 mm (10") shield length Process connections and antenna
options (see page 9)
4 to 20 mA 2-wire current loop
HART or PROFIBUS PA SIMATIC PDM for configuration
and diagnostics
CE, CSANRTL/C, FM, ATEX, ANZEx,IECEx, PED, Lloyds Register ofShipping, ABS Type Approval, 3A,
Industry Canada, FCC, R&TTE
CE, CSANRTL/C, FM, ATEX,Lloyds Register of Shipping,ABS Type Approval, Industry Canada,FCC, R&TTE, CETECOM
Radar level measurement
Range
Process pressure*
Key features
Output
Communications
Powerspecifications
Approvals
Process temperature
-
8/6/2019 Level Guide En
9/16
* Maximum pressure 0.5 bar (7.25 psi) at 60 C. Alternative materials are available upon request by special order; consult your local Siemens Milltronics representative.
>SITRANS
LR 200
>SITRANS
LR 300
Radars sophisticated pulseand Frequency ModulatedContinuous Wave (FMCW)technologies provide reliable
continuous level measurement forshort- to long-range applications,even in harsh process conditionssuch as temperature and pressureextremes, aggressive chemicals,agitation, turbulence, encrustation,and extreme dust.
9
SITRANS LR 200 and LR 300 radar antenna configurations
Antennaversion
Flat-facedflangewith rod andintegralprocess seal
Shielded rodeliminatesnozzleinterference
Sanitary rod(1-piececonstruction)for food andpharmaceuticalapplications
Horn (3", 4",6", 8" sizesavailable)(3" and 4"for stillingwell only)
Waveguidefor lowdielectricproducts
Processconnectiontypes
Nominal pipesizes50, 80, 100, 150 mm(2, 3, 4, 6")
2" threadedNPT, BSP, G
Flat-face flangenominal pipe sizes80, 100 mm(3", 4")
Sanitary flangeconnector2", 3", 4" sizes
Flat-faced flangesANSI, DIN, JIS
Flat-facedflangesANSI, DIN, JIS
Wetted parts PTFE FKM O-ring
PTFE 316 stainless steel
UHMW-PE or PTFE
FKM O-ring PTFE 316 stainless steel
FKM O-ring PTFE 316 stainless
steel
Insertion length(max.)
41 cm (16.3") Variable 41 cm (16.3") Variable withextension
Variable up to 3 m(9.8 ft) max.
Extensions/options
50 or 100 mm(2 or 4") PTFE orUHMW-PE
100, 150, 200 or250 mm(4, 6, 8 or 10")standard shieldlength, or longerby request
N/A Sliding waveguidefor digesterapplications*
Purging
Two sections(max.) can beconnected together
-
8/6/2019 Level Guide En
10/16
MultiRanger and SmartLinx are registered trademarks of Siemens Milltronics Process Instruments Inc.**Also available as Milltronics AiRanger with similar specifications
Ultrasonic level measurement
MultiRanger
100/200Versatile short- to medium-rangeultrasonic single- and multi-vessellevel monitor/controller for virtuallyany application in a wide varietyof industries
Range
Key features
Output
Communi-cations
Powerspecifications
Approvals
Processtemperature
Processpressure
15 m (50 ft) transducer and
material dependent
AC version: 100 to 230 V AC15%, 50/60 Hz, 36 VA/17W
DC version: 12 to 30 V DC 20W
Transducer dependent
Transducer dependent
100 version: Simple pump control
200 version:
Enhanced pump control Differential control Open Channel Flow monitor Volume conversion One mA input
Both versions: Single or dual point AC or DC Digital input for back-up level
override from a point leveldevice (e.g. Pointek CLS 200)
Two discrete inputs Wall or panel mount
3 relays standard 6 relays (option) Two 4 to 20 mA outputs (isolated)
Built-in Modbus RTU or ASCIIvia RS-485
Compatible with SIMATIC PDMvia Modbus RTU
Options: Dolphin Plus SmartLinx (see page 14)
- PROFIBUS DP- Allen-Bradley RIO- DeviceNet
CE, CSANRTL/C, UL Listed, FM
Lloyd's Register of Shipping, ABS
0
SITRANS LU**
Ultrasonic long-range level monit-oring system for liquids and solidsLU 01: 1 point
LU 02: 2 points
LU10: up to 10 points
60 m (200 ft) transducer and
material dependent
LU 01, LU 02 AC version:100/115/200/230 V AC orDC version: 18 to 30 V DC, 25 W
LU10: 100/115/200/230 V AC
Transducer dependent
Transducer dependent
High/low alarm Multi-point measuring:
2 (LU 02)10 (LU 10)
Differential or averagemeasurement
Volume conversion Priority scanning (LU 10) Programmable with handheld
programmer or PC
Options (LU 10): LU AO Analog Output Module LU SAM Satellite Alarm Module
4 relays (LU 01, LU 02) Up to 40 relays (LU 10) 4 to 20 mA (isolated)
Dolphin RS-232/RS-485(LU 01, LU 02)
Dolphin via infrared (LU 10)
Option:SmartLinx (see page 14)
- PROFIBUS DP- Allen-Bradley RIO- DeviceNet
CE, CSANRTL/C, FM
Lloyds Register of Shipping, ABS
Allen-Bradley is a registered trademark of Rockwell Automation.DeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA).
HydroRanger200Ultrasonic level controller forup to 6 pumps control,differential control, and openchannel flow monitoring
SITRANSLUC 500Complete ultrasonic levelcontroller for monitoring andcontrol of water distribution andwastewater collection systems,with energy-saving algorithms
15 m (50 ft) transducer and
material dependent
15 m (50 ft) transducer and
material dependent
Transducer dependentTransducer dependent
Single or dual point Fixed and rotating pump
rosters
Ratio pump runtimes Controls up to 6 pumps Screen rake automation Influent and effluent monitor Open Channel Flow monitor Remote collection monitor Sampler control
Volume conversion Scum line reduction High level back-up alarm input One mA input 2 discrete inputs AC or DC Wall or panel mount
Fixed and rotating pump ros Ratio pump runtimes Time based control options Screen rake automation Influent and effluent monito Remote collection monitor Sampler control Open channel flow monitor RTU and data logger Volume conversion Discrete inputs for pump
interlocks/pump faults feedb Report by exception Combined Sewer Overflow
(CSO) logging
Options: VS 100 Velocity Sensor Wall, rack or panel mount
Built-in Modbus RTU/ASCII viaRS-485
Compatible with SIMATIC PDMvia Modbus RTU
Options:
Dolphin Plus SmartLinx
- PROFIBUS DP- Allen-Bradley RIO- DeviceNet
Telemetry capability with ModbRTU/ASCII via RS-232/RS-485
Options:
Dolphin Plus SmartLinx
- PROFIBUS DP- Allen-Bradley RIO- DeviceNet
AC version: 100 to 230 V AC15%, 50/60 Hz, 36VA/17W
DC version:12 to 30 V DC 20W
AC version:100 to 230 V AC 50/60 Hz, 36VA/17W
DC version: 12 to 30 V DC 20
Transducer dependent Transducer dependent
6 relays standard Two 4 to 20 mA outputs
(isolated)
5 relays, 4 to 20 mA (option)
CE, CSANRTL/C, UL ListedCE, CSANRTL/C, UL Listed, FM, Lloyd's
Register of Shipping, ABS, MCERTS
-
8/6/2019 Level Guide En
11/16
OCM Ill
High accuracy ultrasonicflow monitor for openchannels
3 m (10 ft)
Transducer dependent
Influent and effluentmonitor
Sampler control Low power remote
monitoring Data logger Remote connection via
modem Dual power input
Option: VS 100 Velocity Sensor
Via RS-232
Options: Flow Reporter software
100/115/200/230 V AC,15%, 50/60 Hz, 15 VAand/or
9 to 30 V DC 8W
Transducer dependent
3 relays, 4 to 20 mA
CE, CSANRTL/C, FM, MCERTS
1All Siemens Milltronics transducers have one or more of the following approvals: CE, CSA, FM, ATEX, SAA, ABS, and Lloyds Register of Shipping. For details,specifications and a full list of approvals (Intrinsically Safe, Explosion Proof, Hazardous Locations, Sanitary), see www.siemens.com/level.Echomax is a registered trademark of Siemens Milltronics Process Instruments Inc.
Echomax transducers
Liquids
Standard High temperatureHigh temperature
XRS-5 XPS-10 XPS-30 XPS-40 XCT-8 XCT-12 XLT-30 XLT-60
Liquids and solids Aggressiveliquids
ST-H
Solids
Max. range 10 m(33 ft)
30 m(100 ft)
40 m(130 ft)
8 m(26 ft)
12 m(40 ft)
30 m(100 ft)
60 m(200 ft)
10 m(33 ft)
Min. range 0.3 m(1 ft)
0.3 m(1 ft)
0.6 m(2 ft)
0.9 m(3 ft)
0.6 m(2 ft)
0.6 m(2 ft)
0.9 m(3 ft)
1.8 m(6 ft)
0.3 m(1ft)
Max. temp. 65 C(149 F)
95 C(203 F)
95 C(203 F)
95 C(203 F)
145 C(293 F)
145 C(293 F)
150 C(300 F)
150 C(300 F)
73 C(164 F)
Min. temp. -20 C(-4 F)
-40 C(-40 F)
-40 C(-40 F)
-40 C(-40 F)
-40 C(-40 F)
-40 C(-40 F)
-40 C(-40 F)
-40 C(-40 F)
-40 C(-40 F)
Typicalapplications
Dusty solidsSlurries
PowdersPelletsSolids
PowdersPelletsSolids
Hot acidsSlurriesFood
Hot acidsSlurries
ClinkerCoalBunkers
ClinkerCoalBunkers
Chemicalstorage
Liquidtanks
Frequency 44 kHz 44 kHz 30 kHz 22 kHz 44 kHz 44 kHz 22 kHz 13 kHz 44 kHz
Beam angle-3dB
10 12 6 6 12 6 5 5 12
Thread size 1" BSP/NPT 1" BSP/NPT 1.5"universalthread(BSP/NPT)
1.5"universalthread(BSP/NPT)
1" BSP/NPT 1" BSP/NPT 1" NPT 1" NPT 1" & 2" NPT
Housing PVDFCopolymer
CSMOptional:Flange withPTFE facing
PVDFOptional:
Foamfacing
Flange withPTFE facing
PVDFOptional:
Foamfacing
Flange withPTFE facing
PVDFOptional:
Foam facing
PVDFOptional:
Flange withPTFE facing
Sanitaryversion
PVDFOptional:
Flange withPTFE facing
Aluminum304 stain-
less steelPolyesterSilicone
Aluminum304 stain-
less steelPolyesterSilicone
ETFE
SITRANS LU
SITRANSLUC500
HydroRanger200
MultiRanger100/200
OCM III
Wet wellsOpenchannels
8 m(26 ft)
Compatible with:
Ultrasonic products are the cost-effectivechoice for monitoring and control in short-to long-range applications for liquids, slurriesand solids in a wide range of industries. Non-contacting technology offers low-maintenance
advantages. Siemens Milltronics is the worldleader in ultrasonic level technology, withmany models available and strong applicationexperience to support you.
15 m(50 ft)
0.3 m(1 ft)
95 C(203 F)
-40 C(-40 F)
Deep wetwells
Solids
44 kHz
6
1" BSP/NPT
PVDFOptional:
Foamfacing
Flange withPTFE facing
XPS-15
-
8/6/2019 Level Guide En
12/16
Basic ultrasonic level measurement
Range
Process pressure
Key features
Output
Communications
Power specifications
Approvals
Process temperature
5 m (16.5 ft)
-40 to 60 C (-40 to 140 F)
0.5 bar (7.25 psi)
1 relay, 4 to 20 mA (3-wire) 4 to 20 mA (2-wire)
Built-in temperature compensation Simple 2-button programming PVDF copolymer or ETFE
transducer
3-wire version: 18 to 30 V DC,0.2 A max.
2-wire version: 12 to 28 V DC,0.1 A surge
CE, CSANRTL/C, FM
The ProbeShort-range integrated ultrasoniclevel transmitter; ideal for liquidsand slurries in open or closedvessels
Liquids: 5 m (16.5 ft)Solids: 3 m (9.8 ft)
0.5 bar (7.25 psi)
Built-in temperaturecompensation
Two distinct level points(high level/low level)
Simple 2-button programming
Options: Flange adapter Sanitary mounting
AC version: 2 form C (SPDT)relays (5A at 250 V AC)
DC version: 2 form C (SPDT)relays (48 V DC) or transistor(2 switches; 100 mA at
48 V DC)
CE, CSANRTL/C, FM,CSA/FM, ATEX
Pointek ULS 200Ultrasonic non-contacting switchwith two switch points for leveldetection of bulk solids, liquidsand slurries in a wide variety ofindustries; ideal for sticky materials
-40 to 60 C (-40 to 140 F) -20 to 60 C (-5 to 140 F)
for ATEX model or if mountedin metal
AC version: 100 to 230 V AC, 15%,50/60 Hz, 12 VA/5W max.
DC version: 18 to 30 V DC, 3W
Milltronics simpleultrasonic levelmeasurement instrumentsare the right choice whenyou need reliable,
accurate, cost-effectivelevel measurements.
2
-
8/6/2019 Level Guide En
13/16
1
SITRANS P MPSHydrostatic level monitor fordirect mounting on tanks orvessels
SITRANS P DSIIIHydrostatic level monitor formounting with remote seal onopen or closed vessels withcorrosive or non-corrosive liquids
-10 to 80 C (14 to 176 F) -40 to 100 C (-40 to 212 F)
Vent to atmosphere 32 to 160 bar (2325 psi)
8.3 to 30,000 mbar and 160 barFrom 0 to 2 m H2O,to 0 to 20 m H2O
Compact stainless steel enclosureand sensor
Easy installation
Options: Intrinsically Safe (IS) Special measuring ranges;
0 to 1 m H2O, to 0 to 200 m H2O
Cable length up to 200 m (656 ft)
With remote seals up to400 C (752F)
Self-diagnostic Elements for parameterization
Options: Intrinsically Safe (IS) Explosion proof Flame proof Corrosion-resistant probes Process connections and seals
4 to 20 mA 2-wire 4 to 20 mA
HART SIMATIC PDM compatible PROFIBUS PA
CE, ATEX CE, ATEX, FM/CSA
Standard: 10.5 to 45 V DC Intrinsically Safe: 10.5 to 30 V DC
10 to 36 V DC
Hydrostatic level
Hydrostatic level measurement islow cost for direct mounting orfor mounting with remote seals ontanks and vessels. Theseinstruments can handle extremechemical and mechanical loads aswell as electromagneticinterference. They are widelyapplied in chemical andpetrochemical industries.
Range
Process pressure*
Key features
Communications
Power specifications
Approvals
Process temperature
Output
* Pressure ratings are in bar (psi) gauge, relative
-
8/6/2019 Level Guide En
14/16
SmartLinx provides direct digital connection tocommonly used industrial communicationsbuses with true plug-and-play compatibility.Cards are available for PROFIBUS DP, Modbus RTU,Allen-Bradley Remote I/O, DeviceNet, and ModbusRTU Modem. SmartLinx modules are fast andeasy to install, and can be added at any time.
For use with SITRANS LU, MultiRanger,HydroRanger and SITRANS LUC500.
Flow Reporter
Flow Reporter is a Windows-basedconfiguration software and data extractorfor use with the Milltronics OCM III OpenChannel Meter.
Froma remote PC, it permits you to:
Monitor and troubleshoot flow readingscollected by the OCM III View and modify parameters Connect to OCM III either directly or with a
modem host computer can be any distancefrom the flowmeter
Seek out specific data using the relationaldatabase
Upload data logs from the OCM III Review past and present data logs in a database
environment Export summary information and data to a
spreadsheet program Print daily or monthly reports
Dolphin Plus
Dolphin Plus is instrument configurationsoftware for: SITRANS LU SITRANS LUC500
It helps you configure, monitor, tune and
diagnose most Siemens Milltronics instrumentseither remotely from your desktop PC orconnected directly in the field using a laptop.Just load the software from the CD and inminutes you can set up or modify completeparameter configurations for single or multipleinstruments in the Windows environment.After configuration, you can edit parameters onthe fly, upload and download parameter sets toand from disk, and use parameter sets saved fromother instruments. You can also work with echoprofiles for fine-tuning without the need forspecial instruments.
Windows is a registered trademark of Microsoft Corporation .
Communications solutions
SmartLinxOptional communicationscards
4
Remote datamonitoring withLevelwatch.com
Levelwatch.com unlocks data at remote sitesand distributes it for use in making businessdecisions. Using measuring equipment such asultrasonic, capacitance, radar or other instruments,readings are taken at the remote site.
A Levelwatch.com unit connects this field data
using landline or satellite to a secure web site.The system monitors status, tracks trends, andsends alarms directly to designated personnel byphone, fax, page, or e-mail. Alarm details areavailable on-line.
Levelwatch.com provides the tools for a value-added inventory management service asvendors monitor customer inventory levelsand can anticipate demand and optimizedelivery schedules. Manufacturers can alsomonitor bulk material levels to ensure asupply for continuous production, with nomore running out or emergency deliveries.
Siemens Milltronics products can be connectedvia their Modbus ports, allowing access to keyoperational parameters, such as pump setpoints,and pump or flow totalizers.
SIMATIC PDM software
S IMATIC PDM (Process Device Manager) is amanufacturer-independent software tool for theoperation, configuration, parameterization,maintenance and diagnosis of intelligent fieldinstruments. Based on the EDD standard, it can beused independent of a specific automation systemvia a PC or programming device or as an integral partof the SIMATIC PCS 7 process automation system.
Core functions include:
Set-up and modification of parameters Comparison Plausibility checks Data management Commissioning functions
SIMATIC PDM offers communications via HART,PROFIBUS DP, PROFIBUS PA or other protocols.
See www.siemens.com for up-to-date product list.
HART
HART is a serial transfer protocol which is usedto transfer additional parameter data, such asmeasurement range, configuration, to theconnected device through a 4 to 20 mA powerloop. The main process variable is transmitted viathe 4 to 20 mA power loop. SIMATIC PDM can usethis protocol to communicate configuration datato an instrument. Siemens Milltronics offers HARTas an option on many of our level products.
-
8/6/2019 Level Guide En
15/16
1
PROFIBUS communicationsoffer Totally IntegratedAutomation (TIA)
Siemens offers a range of level instruments thatconnect to a PROFIBUS network. PROFIBUS is thefieldbus standard for complete production plants in allprocess sectors, and helps manufacturers achieveoperational excellence and cost savings throughoutcomplete service life. It is the network solution with themost advantages for Totally Integrated Automation (TIA)
providing digital communication between theautomation system and field instrumentation on asingle, serial bus cable.
Siemens offers a range of radar and ultrasonic leveltransmitters, as well as inverse frequency capacitanceswitches equipped with PROFIBUS PA and ultrasonic levelcontrollers with PROFIBUS DP protocol.
SIMATICPDM
SIMATICPDM
SIMATICPDM
POINTEKCLS 200CLS 300
SITRANSProbe LU
SITRANSProbe LU
POINTEKCLS 500
SITRANSLC 500
SITRANSPD 500SITRANS
LR 300SITRANSLR 200
SITRANSLR 200
SITRANSLR 300 SITRANS
Probe LRSITRANS
LR 400
SITRANS
LR 400
SIMATICPDM
SIMATICPDM
HART
HART
HART
HART
SITRANS LU
31.25 Kbit/s
MultiRanger/HydroRanger
SITRANSLUC500
ProfiNet
PROFIBUS DP Fieldbus
PROFIBUS PA
SIMATIC PCS 7 Engineering Station
with STEP 7, WinCC, and otherswith SIMATIC PDM
Stand-alonecomputerwith SIMATIC PDM
up to 12 Mbit/s
DP/PALink
Coupler
ET200 M/IS
(IM 153-2with HARTmodules)
S7-400 S7-400SIMATIC
PDM
-
8/6/2019 Level Guide En
16/16