Level Measuring Instruments Electromagnetic flowmeters Variable area flowmeters Mass flowmeters Ultrasonic flowmeters Vortex flowmeters Flow controllers Level measuring instruments Pressure and temperature Heat metering Communications technology Switches, counters, displays and recorders Engineering systems & solutions © KROHNE 11/2005 7.02316.26.00 Product Overview Subject to change without notice.

Upload: others

Post on 02-Dec-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Level Measuring Instruments - Marsh Inst

Level MeasuringInstruments

Electromagnetic flowmeters

Variable area flowmeters

Mass flowmeters

Ultrasonic flowmeters

Vortex flowmeters

Flow controllers

Level measuring instruments

Pressure and temperature

Heat metering

Communications technology

Switches, counters, displays and recorders

Engineering systems & solutions

© KROHNE 11/2005 7.02316.26.00

Product Overview

Subject to change without notice.

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:10 Seite 1

Page 2: Level Measuring Instruments - Marsh Inst

KROHNE level production and marketingfacilities are located in Germany, France,the United Kingdom, the United Statesand other countries for a variety of rea-sons. Primarily, it permits us to gain aninternational edge in applications. Wemake our products globally applicable.The latest in quality assurance and aparticularly intense KANBAN productionhelp us to substantially improve deliverytimes.

The KROHNE strategy

KROHNE is present in almost every plantand process in the world. As a globalplayer, we react quickly to our customers’demands, whatever they ask, wheneverthey ask.

We are active members of all importantindustrial associations to make sure weanticipate industrial trends and then setthe benchmarks that others follow.

At KROHNE, we pride ourselves on beingeasy to do business with. Our key objec-tives are to offer the best products foryour applications and to ensure that co-operation with us is as easy as possible by supporting all our sales activities withextensive pre- and post-sales consultancyand technical assistance.

KROHNE - easy to work with.

KROHNELevel MeasuringInstruments

Measurement instruments for Level

An extensive and varied range of mea-suring devices and switches is availablefor level measurement and detection ofliquids and solids. Based on differentmeasuring principles, advanced technol-ogy and strict quality assurance proce-dures, our highly accurate measuringdevices are equal to even the toughestconditions.

In all cases, our measuring devices com-bine high accuracy and reliability witheconomic efficiency. Tell us the applica-tion you have in mind: we’ll supply youwith the ideal KROHNE level measuringsystem.

KROHNE level measuring devices complywith CE requirements and Namur direc-tives. Our production facilities are certi-fied to ISO 9001. Many of our deviceshave official approvals:

� "Ex” approval or equivalent� approval as part of an overfill

protection system,� type approval certificates in confor-

mity with the German pressure vesselcode.

Our devices can be fitted with a widechoice of process connections, accord-ing to customer requirements.

2

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:11 Seite 2

Page 3: Level Measuring Instruments - Marsh Inst

ContinuousRadar

ContinuousUltrasonic

ContinuousTDR

ContinuousBuoyancy

ContinuousPotentiometric

SwitchesVibration

SwitchesElectrom. waves

SwitchesConductive

SoftwarePACTware

3

Switches

Continuous measurement

contactnon-contact

contact

Product Overview

3)Data only applicable for OPTISWITCH 5200 C

4)Data only applicable for OPTISWITCH 3300 C

1)Data only applicable for OPTISOUND 3020 C

2)Data only applicable for OPTISOUND 3040 C

Liquid Interface Powder PasteLiquid Granulates

OPTIWAVE 7300 C OPTIWAVE 7300 C OPTIWAVE 7300 C RadarMax. meas. range 40 m / 131 ft Pressure -1 ... 40 bar / -14.5 ... 580 psigFlange temp. –40 …+200°C / –40 …+390°F

OPTISOUND 3010 C (OPTISOUND 3010 C) (OPTISOUND 3010 C) UltrasonicOPTISOUND 3020 C (OPTISOUND 3020 C) (OPTISOUND 3020 C) Max. meas. range

1)Liquids: 8 m / 26 ft Solids: 3.5 m / 11.5 ft

Pressure1)

-0.2 ... 2 bar / -3 ... 29 psig Product temp.

1)–40 …+80°C / –40 …+175°F

OPTISOUND 3030 C OPTISOUND 3030 C OPTISOUND 3030 C Max. meas. range2)

Liquids: 1 ... 25 m / 3.3 ... 82 ft (OPTISOUND 3040 C) OPTISOUND 3040 C OPTISOUND 3040 C Solids: 1 ... 15 m / 3.3 ... 49 ft (OPTISOUND 3050 C) OPTISOUND 3050 C OPTISOUND 3050 C Pressure

2)-0.2 ... 1.5 bar / -3 ... 22 psig

Product temp.2)

–40 …+80°C / –40 …+175°F

OPTIFLEX 1300 C OPTIFLEX 1300 C OPTIFLEX 1300 C OPTIFLEX 1300 C Guided Radar (TDR)Max. meas. range 35 m / 115 ftPressure -1 ... 40 bar / -14.5 ... 580 psigFlange temp. –40…+200°C / –40…+390°F

BM 26 A BM 26 A BuoyancyMax. length 6 m / 19.7 ftPressure -1 ... 120 bar / -14.5 ... 1740 psigProduct temp. –200…+300°C / –325…+570°F

BM 500 BM 500 PotentiometricMax. length 2 m / 7 ftPressure -1 ... 16 bar / -14.5 ... 230 psigProduct temp. –20…+140°C / –4…+285°F

Liquid Interface Powder PasteLiquid Granulates

OPTISWITCH 4100 VibrationOPTISWITCH 5100 Max. sensor length

3)6 m / 19.7 ft

OPTISWITCH 5150 Pressure3)

-1 ... 64 bar / -14.5 ... 930 psig OPTISWITCH 5200 Product temp.

3)–50…+250°C / –58…+480°F

OPTISWITCH 5250

OPTISWITCH Max. sensor length4)

6 m / 20 ft3000 series Pressure

4)-1 ... 16 bar / -14.5 ... 230 psig

Product temp.4)

–50 …+250°C / –60 …+480°F (with temp. adapter)

LS 6200 LS 6250S LS 6200 Electromagnetic wavesLS 6300 LS 6300 Pressure -1 ... 16 bar / -14.5 ... 230 psig

Product temp. –20…+140°C / –4…+285°F

LS 7200/7201 ConductiveLS 7210/7211 Pressure -1 ... 16 bar / -14.5 ... 230 psig LS 7220/7221 Product temp. –20…+140°C / –4…+285°F

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:11 Seite 3

Page 4: Level Measuring Instruments - Marsh Inst

4

OPTIWAVE – Works better than any radar ever before

Continuous Radar and TDR

OPTIWAVE 7300 C

In contrast to earlier radar devices,the new OPTIWAVE is able to operateover a larger bandwidth. This ensuresa sharper resolution and higher accu-racy. The higher signal dynamics ofOPTIWAVE allow the detection of eventhe smallest level changes.• Simple installation

• Wizard driven

• PACTware-ready

• Easy to use

• Service and maintenance-free

Objects in tankAgitators, struts, inlets, ladders andsimilar objects have less effect onsignal reduction.The high-quality signal is easier toevaluate and the results are moreaccurate and repeatable.

FoamThe improved signal quality permitsmuch clearer location of the product'strue surface.

Agitated surface

Better signal production and improvedPCB board characteristics allow theOPTIWAVE to determine the true levelin the tank despite the agitated sur-face.

For all applications

• Objects in tank

• Foam

• Agitated surface

OPTIWAVE 7300 C

Product Liquids, pastes and solids

Max. measuring range 40 m / 131 ft

Accuracy ±3 mm / ±0.12" (when L ≤ 10 m / 33 ft)±0.03 % of measured distance(when L > 10 m / 33 ft)

Operating dataPressure -1…40 bar / -14.5…580 psigFlange temperature -40…+200°C / -40…+390°F (std.)

Process connection NPT 1 1/2"; G 1 1/2"Flange DN 40…DN 150 (PN 40 / PN 16); 1 1/2"…8" (150 lb / 300 lb); 10 K (40…100A)

Materials(Wetted parts) Stainless steel (1.4404 / 316L);

Hastelloy® C-22 (2.4602)

Human machine interface Display in 9 languages, even in Chinese, Japanese and Russian

ApprovalsATEX ATEX II G/D

1, 1/2, 2 EEx ia IIC T6 ... T3ATEX II G/D 1/2, 2 EEx d [ia] IIC T6 ... T3

FM / CSA: NEC 500/CEC: Cl. I, Div. 1, Gr. ABCD (CSA: BCD only) (IS)Cl. I, Div. 1, Gr. ABCD (FM only) (XP) (XP/IS)Cl. I, Div. 2, Gr. ABCD (CSA: BCD only) (IS & XP)Cl. II, Div. 1, Gr. EFG; Cl. III (FM only) (XP)Cl. II Div. 1/2, Gr. EFG; Cl. III (IS)Cl. II/III, Div. 2, Gr. FG (XP/NI)

NEC 505/CEC: Cl. I, Zone 0 AEx ia, Gr. IIC (IS);Cl. I, Zone 1 AEx d [ia], Gr. IIC (XP);Cl. I, Zone 2, AEx nA [ia], Gr. IIC (NI)

WHG (pending) Overfill protection

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:12 Seite 4

Page 5: Level Measuring Instruments - Marsh Inst

5

OPTIFLEX – Designed to satisfybetter than any other TDR

OPTIFLEX 1300 C

Various probe types and materials to cover all applications

For all applications

• No interface too thin• Stable and reliable measurement• Measures any product

in any application

OPTIFLEX 1300 C

In contrast to earlier guided radardevices, the new OPTIFLEX with itsmore advanced design solutions hashigher signal dynamics. Sharper puls-es measure thinner interfaces.OPTIFLEX’s exceptional timebase stabi-lity means it has better repeatabilitythan older devices: this makes it anoutstandingly reliable meter.

• Simple installation

• Wizard driven

• PACTware-ready

• Easy to use

• Service and maintenance-free

No interface is too thin OPTIFLEX can detect and measureinterfaces not much thicker than a 50 mm / 2" film of oil on water in alarge tank.

Stable and reliable measurementDespite disturbances such as stronglyagitated surfaces, foam, coating of the probe or fine dust in the tank,OPTIFLEX will continue to measurewhere competitors' devices capitulate.

OPTIFLEX measures any product ...Most 2-wire TDR devices measuredown to a dielectric of 1.5. As aresult, many organic compounds arenot measured properly. OPTIFLEXmeasures down to 1.4 (and even 1.1using its first-rate tank-bottom follow-ing mode).

... in any application5 different probes means there's notan application that we can't handle.

ContinuousRadar

ContinuousUltrasonic

ContinuousTDR

ContinuousBuoyancy

ContinuousPotentiometric

SwitchesVibration

SwitchesElectrom. waves

SwitchesConductive

SoftwarePACTware

Product Liquids, liquid interface, pastes and solids

Max. measuring range 35 m / 115 ft

Accuracy Liquids: ±3 mm / 0.12"(in direct mode) (L < 10 m / 33 ft);

± 0.03 % of measured distance(L > 10 m / 33 ft) Powders: ±20 mm / ±0.8" Interface: ±10 mm / ±0.4" ( constant)

(in TBF mode) ±20 mm / ±0.8" ( constant)

Operating dataPressure -1…40 bar / -14.5…580 psigFlange temperature -40…+200°C / -40…+390°F (std.)

Process connection G 3/4" ... 1 1/2"; 3/4" ... 1 1/2" NPTFlange DN 25…DN 150 (PN 40 / PN 16);1"…8" (150 lb / 300 lb); 10 K (40…100A)

Materials(Wetted parts) Stainless steel (1.4404/316 L),

Stainless steel (1.4401/316)Hastelloy® C-22 (2.4602)

Human machine interface Display in 9 languages, even in Chinese, Japanese and Russian

ApprovalsATEX ATEX II G/D

1, 1/2, 2 EEx ia IIC T6 ... T3ATEX II G/D 1/2, 2 EEx d [ia] IIC T6 ... T3

FM / CSA: NEC 500/CEC: Cl. I, Div. 1, Gr. ABCD (CSA: BCD only) (IS)Cl. I, Div. 1, Gr. ABCD (FM only) (XP) (XP/IS)Cl. I, Div. 2, Gr. ABCD (CSA: BCD only) (IS & XP)Cl. II, Div. 1, Gr. EFG; Cl. III (FM only) (XP)Cl. II Div. 1/2, Gr. EFG; Cl. III (IS)Cl. II/III, Div. 2, Gr. FG (XP/NI)

NEC 505/CEC: Cl. I, Zone 0 AEx ia, Gr. IIC (IS);Cl. I, Zone 1 AEx d [ia], Gr. IIC (XP);Cl. I, Zone 2, AEx nA [ia], Gr. IIC (NI)

WHG (pending) Overfill protection

3r

3r

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:13 Seite 5

Page 6: Level Measuring Instruments - Marsh Inst

Product Liquids, (solids) Liquids, (solids) Liquids, solids

Max. measuring range Liquids: 5 m / 16 ft Liquids: 8 m / 26 ft Liquids: 15 m / 49 ftSolids: 2 m / 7 ft Solids: 3.5 m / 11.5 ft Solids: 7 m / 23 ft

Accuracy Better than 0.2% or +/- 4 mm Better than 0.2% or +/- 4 mm Better than 0.2% or +/- 6 mm

Operating dataPressure -0.2 ... 2 bar / -3 ... 30 psi -0.2 ... 2 bar / -3 ... 30 psi -0.2 ... 1 bar / -3 ... 14.5 psiTemperature –40°C ... +80°C / –40°C ... +80°C / –40°C ... +80°C /

–40°F ... +180°F –40°F ... +180°F –40°F ... +180°F

Process connection G11/2"A G2A Compression flange DN 100;mounting strap

Materials(Wetted parts) PVDF, EPDM PVDF, EPDM Stainless steel 1.4301 (304),

1.4571 (316 Ti), UP, EPDM

Options 2-wire / 4-wire 2-wire / 4-wire 2-wire / 4-wire 4 ... 20 mA / HART® 4 ... 20 mA / HART® 4 ... 20 mA / HART®

ApprovalsATEX II 1G, 1/2G, 2G EEx ia IIC T6 II 1G, 1/2G, 2G EEx ia IIC T6 -

6

OPTISOUND 3010 C – 3030 C – for Liquids

Continuous Ultrasonic

OPTISOUND 3010 C – 3030 C

OPTISOUND 3010 C -3030 C areultrasonic sensors for continuouslevel measurement, suitable for liquidsand solids in virtually all industries,particularly in the water and waste-water industry. The transducer of theultrasonic sensor emits short ultra-sonic pulses to the measured prod-uct. These pulses are reflected by theproduct surface and received by thetransducer as echoes. The runningtime of the ultrasonic pulses fromemission to reception is proportionalto the distance and hence to the level.The determined level is convertedinto an appropriate output signal andoutputted as measured value.

Fields of application

• Level measurement during pro-cessing and storage of liquids

• Sumps, water and wastewaterbasins

• Noncontact flow measurementand detection in open channels

OPTISOUND 3010 C OPTISOUND 3020 C OPTISOUND 3030 C

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:13 Seite 6

Page 7: Level Measuring Instruments - Marsh Inst

Product Liquids, solids Solids, (liquids) Solids, (liquids)

Max. measuring range Liquids: 15 m / 49 ft Liquids: 25 m / 82 ft Liquids: 45 m / 147.6 ftSolids: 7 m / 23 ft Solids: 15 m / 49 ft Solids: 25 m / 82 ft

Accuracy Better than 0.2% or +/- 6 mm Better than 0.2% or +/- 6 mm Better than 0.2% or +/- 6 mm

Operating dataPressure -0.2 ... 1 bar / -3 ... 14.5 psi -0.2 ... 1.5 bar / -3 ... 20 psi -0.2 ... 1.5 bar / -3 ... 20 psiTemperature –40°C ... +80°C / –40°C ... +80°C / –40°C ... +80°C /

–40°F ... +180°F –40°F ... +180°F –40°F ... +180°F

Process connection Compression flange DN 100, flange DN 200, with swivelling flange DN 250, with swivellingmounting strap holder ≥ DN 50 holder ≥ DN 50

Materials(Wetted parts) Stainless steel 1.4301 (304), PP, Alu, galvanized steel, PA, UP, PP, Alu, galvanized steel, PA, UP,

1.4571 (316 Ti), UP, EPDM stainless steel 316 Ti Alu/PE foam rubber coating

Options 2-wire / 4-wire 4-wire 4-wire 4 ... 20 mA / HART® 4 ... 20 mA / HART® 4 ... 20 mA / HART®

ApprovalsATEX - II 1/2 D IP66 T II 1/2 D IP66 T

7

OPTISOUND 3030 C – 3050 C – for Solids

OPTISOUND 3030 C – 3050 C

OPTISOUND 3030 C - 3050C areultrasonic sensors for continuouslevel measurement, particularly suit-able for solids, but also good for liquids.The transducer of the ultrasonic sen-sor emits short ultrasonic pulses tothe measured product. These pulsesare reflected by the product surfaceand received by the transducer asechoes. The running time of the ultra-sonic pulses from emission to recep-tion is proportional to the distanceand hence to the level. The deter-mined level is converted into anappropriate output signal and out-putted as measured value.

Fields of application

• Level measurement during pro-cessing and storage of solids

• Level indication of solids in silosand hoppers

• Level measurement in stonecrushers

• Profile measurement on conveyorbelts

ContinuousRadar

ContinuousUltrasonic

ContinuousTDR

ContinuousBuoyancy

ContinuousPotentiometric

SwitchesVibration

SwitchesElectrom. waves

SwitchesConductive

SoftwarePACTware

OPTISOUND 3030 C OPTISOUND 3040 C OPTISOUND 3050 C

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:13 Seite 7

Page 8: Level Measuring Instruments - Marsh Inst

8

BM 26 / BM 26 A – Bypass LevelIndicator

Continuous Buoyancy and Potentiometric

BM 26 / BM 26 A

The BM 26 operates on the principleof communicating vessels.The measuring chamber is connectedto the side of the tank so that thesame conditions are obtained in thechamber as those in the tank.The float is equipped with a systemof permanent magnets to transmitmeasured values to the local indica-tor.The magnetic field generated by thefloat either rotates a column of mag-netic yellow– and black-sided flapsaccording to the liquid level, or dis-places a follower magnet in the glassindication tube, depending on themethod of indication chosen.The number of reversed yellow mag-netic flaps, or the vertical position ofthe follower magnet, indicates the liq-uid level.

• For Level or Interfacemeasurement

• Particularly suitable for use withhighly corrosive, noxious or flam-mable substances and ideal for severe operating conditions

• Simple rugged design

BM 26 A

Limit switch options

MS 15 EXD MS 15 EXI MS 20 EXI

Product Liquids

Measuring range (standard) 0.3 ... 6 m / 1 ... 20 ft

Accuracy ± 10 mm /± 0.4" of measured value

Operating dataPressure, standard -1 ... 40 bar / -14.5 ... 580 psigPressure, option 120 bar / 1740 psigTemperature, standard -40°C … +200°C /

-40 … +390°F Temperature, option -200°C … +300°C /

-325 … +570°FDensity ≥ 0.5 kg/l / 21.2 lb/ft3

Viscosity max. 5000 mPa· s / 3.36 lb/ft·s

Process connection Flange DN 15 ... DN 50 / 1/2" ... 2"

Materials(Wetted parts) Stainless steel, titanium,

Hastelloy, PTFE, PVC, PVDF/ hard glass

Options/Accessories Limit switches, Level transducer,Heating system, High temperature/low temperature lagging

ApprovalsATEX ATEX II 1/2 G or ATEX II 1 G

EEx d ia IIC T3 ... T6 or EEx d IIC T3 ... T6, EEx ia IIC T3 ... T6

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:13 Seite 8

Page 9: Level Measuring Instruments - Marsh Inst

9

BM 500 – dependable level measurement solutionfor hygienic applications

BM 500

The BM 500 level transmitter operateson the potentiometric measuring prin-ciple and is designed for use in allelectrically conductive products witha minimum conductivity of 1 µS/cm(e.g. distilled water).This method is particularly suitablefor measuring level in small vesselscontaining paste, heavy caking or viscous products.The electronic evaluation unit is inte-grated in the connecting head andsupplies an output signal of 4 … 20mAthat is proportional to level.The HWM 500 hygienic process welding sleeve ensures installation inconformity with standards of hygiene.Due to its ability to withstand hightemperatures (140°C / 285°F), theBM 500 is eminently suitable for CIPcleaning and sterilizing processes.

• Hygienic installation

• Measurement independent ofproduct properties

• Unaffected by deposits andfoam

• Particularly suitable for smalltanks

• Level measurement possiblefrom 50 mm / 2’’

• Fast response time

BM 500

Product Liquids, pastes

Measuring range (standard) 2 m / 7 ft

Repeatability ± 4 mm / ± 0.15"

Operating dataPressure -1 ... 16 bar / -14.5 ... 230 psig Temperature -20°C … +140°C /

-4°F … +285°FConductivity ≥ 1 µS/cm

Process connection Tri-Clamp, TuchenhagenVarivent, SMS, 11851

Materials(Wetted parts) Stainless steel

Options/Accessories Hygienic adapter sleeve

Approvals EHEDG, 3A

ContinuousRadar

ContinuousUltrasonic

ContinuousTDR

ContinuousBuoyancy

ContinuousPotentiometric

SwitchesVibration

SwitchesElectrom. waves

SwitchesConductive

SoftwarePACTware

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:14 Seite 9

Page 10: Level Measuring Instruments - Marsh Inst

10

OPTISWITCH 3000 series

Switches Vibration

OPTISWITCH 3000 seriesThe tuning fork is piezoelectricallyenergised and vibrates at itsmechanical resonance frequency ofapprox. 145 Hz. The piezoelectric ele-ments are fastened mechanically andare therefore not subject to tempera-ture shock limitations. When the tun-ing fork is immersed in the product,the amplitude of the vibrationchanges. This change is detected bythe integrated electronics and con-verted into a switching command.

The models OPTISWITCH 3100 C,3200 C and 3300 C are available instandard, cable and tube versions.These are ideal for numerous appli-cations thanks to the many processoptions available. They are completelymade of stainless steel and have allstandard approvals.

Unlike the other models in the series,the OPTISWITCH 3000 C has a smallnumber of options. It is a cheapmodel with a plastic threaded processconnection, a plastic housing and noapprovals.

Fields of application

• Overfill and dry run protection

• Nearly unaffected by the chemicaland physical properties of thesolid

OPTISWITCH 3000 C OPTISWITCH 3100 C

Product Solids Solids

Max. sensor length – –

Density > 0.08 g/cm3 (> 0.003 lbs/in3) > 0.08 g/cm3 (> 0.003 lbs/in3)

Operating dataPressure -1 ... 6 bar / -14.5 ... 90 psi -1 ... 16 bar / -14.5 ... 230 psiTemperature –50°C ... +100°C / –50°C ... +250°C /

–60°F ... +210°F –60°F ... +480°F (with temp. adapter)

Process connection G11/2"A G11/2"A; flanges

Materials(Wetted parts) Stainless steel 316 L, PP Stainless steel 316 L

Options / Accessories Relay, transistor, 2-wire output, Relay, transistor, 2-wirecontactless electronic switch 8/16 mA output, contactless

electronic switch

ApprovalsATEX – II 1/2 G, 2G EEx d IIC T6 (Electronics C, R, T) II 1/2 D, IP6X T

(Electronics 2-wire) II 1G, 1/2 G, 2 G EEx ia IIC T6 II 1G, 1/2 G, 2 G EEx ia IIC T6 +II 1/2 D IP6X TII 1/2 G, 2 G EEx d IIC T6 II 1/2 D IP6X T

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:14 Seite 10

Page 11: Level Measuring Instruments - Marsh Inst

11

Ideal for solids

OPTISWITCH 3200 C OPTISWITCH 3300 C

ContinuousRadar

ContinuousUltrasonic

ContinuousTDR

ContinuousBuoyancy

ContinuousPotentiometric

SwitchesVibration

SwitchesElectrom. waves

SwitchesConductive

SoftwarePACTware

Product Solids Solids

Max. sensor length 80 m / 260 ft 6 m / 20 ft

Density > 0.08 g/cm3 (> 0.003 lbs/in3) > 0.08 g/cm3 (> 0.003 lbs/in3)

Operating dataPressure -1 ... 6 bar / -14.5 ... 90 psi -1 ...16 bar / -14.5 ... 230 psiTemperature –20°C ... +80°C / –50°C ... +250°C /

–5°F ... +180°F –60°F ... +480°F(with temp. adapter)

Process connection G11/2"A; flanges G11/2"A; flanges

Materials(Wetted parts) Stainless steel 316 L, Stainless steel 316 L

PUR, CR, NBR

Options / Accessories Relay, transistor, 2-wire 8/16 mA Relay, transistor, 2-wire 8/16 mAoutput, contactless electronic output, contactless electronicswitch switch

ApprovalsATEX II 1/2 D IP6X T II 1/2 G, 2 G EEx d IIC T6 (Electronics C, R, T) II 1/2 D IP6X T

(Electronics 2-wire) II 1 G, 1/2 G, 2 G EEx ia IIC T6 II 1 G, 1/2 G, 2 G EEx ia IIC T6 II 1 G, 1/2 G, 2 G EEx ia IIC T6 + II 1 G, 1/2 G, 2 G EEx ia IIC T6 + II 1/2 D IP6X T II 1/2 D IP6X T

II 1/2 G, 2 G EEx d IIC T6 II 1/2 D IP6X T

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:15 Seite 11

Page 12: Level Measuring Instruments - Marsh Inst

12

OPTISWITCH 4100 – economical and compact

Switches Vibration

OPTISWITCH 4100

The tuning fork is piezoelectricallyenergised and vibrates at its mecha-nical resonance frequency of approx.400 Hz. This frequency is transferredto the OPTISWITCH 4100 electronics.When the tuning fork is submerged inthe product, the frequency changes.This change is detected by the inte-grated electronics and converted into a switching command.

• Set-up without adjustment

• Economical and compact

• Unaffected by product variationsin density, conductivity, dielec-tric constant or viscosity

• Insensitive to foam, pressureand temperatures variations

• Insensitive to external vibrations

• Off-the-shelf design

• Proven technology

Fields of application

• Overfill or dry-run protection

• Particularly suitable for applica-tions in confined spaces

OPTISWITCH 4100

Product Liquids

Max. sensor length 100 mm / 0.3 ft

Repeatability ± 2 mm / ± 0.08"

Operating dataPressure -1 ... 40 bar / -14.5 ... 580 psigTemperature -40°C … +150°C /

-40°F … +300°FDensity ≤ 0.6 kg/l / 37.5 lb/ft3

Viscosity max. 10 000 mPa · s

Process connection G1A, NPT 1"

Materials(Wetted parts) Stainless steel 1.4571 (316 Ti)

ApprovalsWHG Overfill protection

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:16 Seite 12

Page 13: Level Measuring Instruments - Marsh Inst

13

OPTISWITCH 5000 series – ideal for liquids

OPTISWITCH 5000 seriesThe tuning fork is piezoelectricallyenergised and vibrates at itsmechanical resonance frequency ofapprox. 1200 Hz. The piezoelectricelements are fastened mechanicallyand are therefore not subject to tem-perature shock limitations. When thetuning fork is immersed in the prod-uct, the frequency changes. Thischange is detected by the integratedelectronics and converted into aswitching command. The modelsOPTISWITCH 5100 and 5150 areshort versions without extension,whereas OPTISWITCH 5200 and5250 can be ordered with extensiontubes. The level switches OPTISWITCH5150 and 5250 have a polished sur-face especially suitable for hygienicapplications.

• Set-up without adjustment

• Integrated fault monitoring

• Unaffected by product variationsin density, conductivity, dielec-tric constant or viscosity

• Insensitive to foam, pressureand temperatures variations

• Insensitive to external vibrations

• Electronics replaceable underprocess conditions

Fields of application

• Overfill or dry-run protection

• Suitable for applications in con-fined spaces (fork length only 40 mm / 1.6”)

OPTISWITCH 5000 seriesProduct Liquids

Max. sensor length 6 m / 19.7 ft

Repeatability ± 2 mm / ± 0.08"

Operating dataPressure -1 ... 64 bar / -14.5 ... 930 psigTemperature -50°C … +250°C /(with temp. adapter) -60°F … +480°FDensity 0.5 ... 2.5 kg/l /

31.2 ... 155.8 lb/ft3

Viscosity max. 10 000 mPa · s

Process connection G 3/4"A; 3/4" NPT; G1A; 1 NPTFlange ≥ DN 25 / 1",Bolting, Tri-Clamp, Cone,Tuchenhagen Varivent

Materials(Wetted parts) Stainless steel 316 L,

Hastelloy® C4,Hastelloy® C4 enamelled,Stainless steel ECTFE/PFA coated

Options/Accessories Outputs: NAMUR, 2-wire 8/16 mA,double relay, transistor, contact-less switch, welding socket

ApprovalsATEX ATEX II 1/2 G EEx d IIC T2 ... T6

N/Z-electronics: ATEX II 1 G orII 1/2 G or II 2 G EEx ia IIC T6

FM IS Class I, II, III; Div. 1; Gr. A ... GXP Class I; Div. 1; Gr. A ... D NIClass I; Div. 2; Gr. ABCDFG Class I;Zone 0; AEx ia; Gr. IIC Type 4X/6

WHG Overfill protection

ContinuousRadar

ContinuousUltrasonic

ContinuousTDR

ContinuousBuoyancy

ContinuousPotentiometric

SwitchesVibration

SwitchesElectrom. waves

SwitchesConductive

SoftwarePACTware

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:16 Seite 13

Page 14: Level Measuring Instruments - Marsh Inst

14

LS 6200 / LS 6300 – limit switch for liquids and pastes

Switches Electromagnetic waves and Conductive

LS 6200 / LS 6300

Electromagnetic waves penetrate theliquid product and their transit timechanges as a function of the dielec-tric constant.This measurement method can beused for all applications includingprocesses that involve changing theproduct.Deposits, foam and condensate arenot detected. The hygienic processwelding sleeve ensures virtually flush-front installation in conformity withhygiene standards.

• For universal use, insensitive toadhesive substances and foam

• No pipe blockages, no pressuredrop independent of locationand vibration

• Hygienic installation

• Fast response time

Fields of application

• Level detection

• Dry-run protection for pipes sizedDN 15 / DN 25 and higher

LS 6200 LS 6300

Accessories

Product Liquids, pastes Liquids, pastes, slurries

Repeatability ± 2 mm / ± 0.08" ± 2 mm / ± 0.08"

Operating dataPressure -1 ... 16 bar / -14.5 ... 230 psig -1 ... 16 bar / -14.5 ... 230 psigTemperature –20°C ... +140°C / –20°C ... +130°C /

–5°F ... +285°F –5°F ... +265°FDensity 0.8 kg/l / 49.8 lb/ft3 0.6 kg/l / 37.5 lb/ft3

Dielectric constant > 10 (≥ 1.4 for LS 6250S) > 10 (≥ 1.4 for LS 6300S)

Process connection Tri-Clamp, Tuchenhagen Tri-Clamp, TuchenhagenVarivent, SMS, 11851 Varivent, SMS, 11851

Materials(Wetted parts) Stainless steel 316 Ti, PEEK Stainless steel 316 Ti, PEEK

Options/Accessories Hygienic adapter sleeve Hygienic adapter sleeve

Approvals EHEDG, 3A EHEDG, 3A

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:17 Seite 14

Page 15: Level Measuring Instruments - Marsh Inst

15

LS 7200 – LS 7241 for detecting the level of conductive liquids or dry-run protection of pumps

LS 7200 – LS 7241

The hygienic conductive sensors typeLS 72XX pick up the electrical resis-tance of the tank product when theelectrode is in contact with the prod-uct. The wall of the vessel or the pipeacts as reverse potential.

Stump electrodes for pipe installation(LS 7200/7201) or mono or multiplerods (LS 7210-7240) are availablefor installation in tanks.The sensor rods are made from stain-less steel or coated to make theminsensitive for foam or product buildup. Sensor rods can be shortenedwithout special tools.

• Optimized flow geometry

• Precise switching point

• Hygienic installation

The electronics is either integrated inthe electronic compartment or can be placed in the panel room.On varying products (with differentconductivities), the sensitivity can beadjusted via a contact input.

With a huge variety of hygienicprocess connections, a crevice-freeinstallation can be achieved. Theseconnections are EHEDG-approved asthey are so easy to clean.

LS 7200 – LS 7241

Accessories

Product Liquids

Max. length 1 m / 3.3 ft

Repeatability ± 2 mm / ± 0.08"

Operating dataPressure -1 ... 16 bar / -14.5 ... 230 psigTemperature -20°C … +140°C /

-5°F … +285°F

Process connection Tri-Clamp, TuchenhagenVarivent, SMS, 11851

Materials(Wetted parts) Stainless steel 316 Ti,

PTFE coated, PEEK

Options/Accessories Hygienic adapter sleeve,External level converter module

Approvals EHEDG, 3A

ContinuousRadar

ContinuousUltrasonic

ContinuousTDR

ContinuousBuoyancy

ContinuousPotentiometric

SwitchesVibration

SwitchesElectrom. waves

SwitchesConductive

SoftwarePACTware

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:18 Seite 15

Page 16: Level Measuring Instruments - Marsh Inst

16

PACTware – simple and intuitive

Standard Configuration Tool for KROHNE devices

Oscilloscope screen (TDR)

Table graph (Radar and TDR)

Empty spectrum screen (Radar)

PACTware

OPTIFLEX and OPTIWAVE are PACTware-ready. Each device is supplied ex fac-tory with the appropriate DTM (DeviceType Manager).A DTM is a device driver making avail-able the device functionality indepen-dent from the FIELDBUS protocol andproviding a graphical user interfaceoptimized for device operation andconfiguration.Simple on-screen and intuitive setupprocedure for devices without a dis-play, or for set up from the CentralControl Room. Summarized setup provides perfect control of initial input, and guarantees perfect results.All features of PACTware are fully sup-ported:

• Displays measured values

• Records measured informationduring operation

• Shows status of device

• Gives stepwise setup with on-screen progress check

• Displays summary of setupselection for final supervision

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:18 Seite 16

Page 17: Level Measuring Instruments - Marsh Inst

17

ContinuousRadar

ContinuousUltrasonic

ContinuousTDR

ContinuousBuoyancy

ContinuousPotentiometric

SwitchesVibration

SwitchesElectrom. waves

SwitchesConductive

SoftwarePACTware

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:18 Seite 17

Page 18: Level Measuring Instruments - Marsh Inst

18

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:18 Seite 18

Page 19: Level Measuring Instruments - Marsh Inst

19

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:18 Seite 19

Page 20: Level Measuring Instruments - Marsh Inst

AustraliaKROHNE Australia Pty Ltd Quantum Business Park10/287 Victoria RdRydalmere NSW 2116TEL.: +61 2 8846 1700FAX: +61 2 8846 1755e-mail: [email protected]

AustriaKROHNE Austria Ges.m.b.H.Modecenterstraße 14A-1030 WienTEL.: +43(0)1/203 45 32FAX: +43(0)1/203 47 78e-mail: [email protected]

BelgiumKROHNE Belgium N.V.Brusselstraat 320B-1702 Groot BijgaardenTEL.: +32(0)2-4 66 00 10FAX: +32(0)2-4 66 08 00e-mail: [email protected]

BrazilKROHNE ConautControles Automaticos Ltda.Estrada Das Águas Espraiadas, 230 C.P. 5606835 - 080 EMBU - SPTEL.: +55(0)11-4785-2700FAX: +55(0)11-4785-2768e-mail: [email protected]

ChinaKROHNE Measurement Instruments(Shanghai) Co. Ltd., (KMIC)Room 1501, Tower ACity Centre of Shanghai100 Zun Yi RoadShanghai 200051TEL.: +86 21 6237 2770FAX: +86 21 6237 2771Cellphone: +86 (0) 139 01954185e-mail: [email protected]

CISKanex KROHNE Engineering AGBusiness-Centre Planeta, Office 404ul. Marxistskaja 3109147 Moscow/RussiaTEL.: +7(0)095-9117165FAX: +7(0)095-7428873e-mail: [email protected]

Czech RepublicKROHNE CZ, spol. s r.o.Sobe×s×ická 156CZ-63800 BrnoTEL.: +420 545 532 111FAX: +420 545 220 093e-mail: [email protected]

AlgeriaArgentinaBelarusCameroonCanadaChile ColombiaCroatiaDenmarkEcuadorEgyptFinlandGabonGhanaGreeceHong KongHungaryIndonesiaIvory CoastIranIrelandIsraelJapan Jordan

KuwaitLibyaLithuaniaMalaysiaMoroccoMauritiusMexicoNew ZealandPeruPolandPortugalRomaniaSaudi ArabiaSenegalSlovakiaSloveniaSwedenTaiwanThailandTurkeyTunisiaVenezuelaYugoslavia

FranceKROHNE S.A.S.Les OrsBP 98F-26103 ROMANS CedexTEL.: +33(0)4-75 05 44 00FAX: +33(0)4-75 05 00 48e-mail: [email protected]

GermanyKROHNE MesstechnikGmbH & Co. KGLudwig-Krohne-Str.D-47058 DuisburgTEL.: +49(0)203-301-0FAX: +49(0)203-301-10 389e-mail: [email protected]

IndiaKROHNE Marshall Ltd.A-34/35, M.I.D.C.Industrial Area, H-Block,Pimpri Poona 411018TEL.: +91(0)202-7442020FAX: +91(0)202-7442020e-mail: [email protected]

IranKROHNE Liaison Office North Sohrevardi Ave.26, Sarmad St., Apt. #9 Tehran 15539 TEL.: ++98-21-874-5973 FAX: ++98-21-850-1268 e-mail: [email protected]

ItalyKROHNE Italia Srl.Via V. Monti 75I-20145 MilanoTEL.: +39(0)2-4 30 06 61FAX: +39(0)2-43 00 66 66e-mail: [email protected]

KoreaKROHNE Korea Room 508 Miwon Bldg 43 Yoido-Dong Youngdeungpo-Ku Seoul, Korea TEL.: 00-82-2-780-1743 FAX: 00-82-2-780-1749 e-mail: [email protected]

NetherlandsKROHNE AltometerKerkeplaat 12 NL-3313 LC DordrechtTEL.: +31(0)78-6306300FAX: +31(0)78-6306390e-mail: [email protected]

NetherlandsKROHNE Nederland B.V.Kerkeplaat 14NL-3313 LC DordrechtTEL.: +31(0)78-6306200FAX: +31(0)78-6306405Service Direkt: +31(0)78-6306222e-mail: [email protected]

NorwayKROHNE Norway A.S.Ekholtveien 114 NO-1526 MossP.O. Box 2178, NO-1521 MossTEL.: +47(0)69-264860FAX: +47(0)69-267333e-mail: [email protected]: www.krohne.no

SingaporeTokyo Keiso - KROHNE Singapore Pte. Ltd.14, International Business Park,Jurong EastChiyoda Building #01-01/02Singapore 609922SingaporeTEL.: ++65-65-67-4548FAX: ++65-65-67-9874

South AfricaKROHNE Pty. Ltd.163 New RoadHalfway House Ext. 13MidrandTEL.: +27(0)11-315-2685FAX: +27(0)11-805-0531e-mail: [email protected]

SpainI.I. KROHNE Iberia, S.r.L.Poligono Industrial NiloCalle Brasil, n°. 5E-28806 Alcalá de Henares -MadridTEL.: +34(0)91-8 83 21 52FAX: +34(0)91-8 83 48 54e-mail: [email protected]

SwitzerlandKROHNE AGUferstr. 90CH-4019 BaselTEL.: +41(0)61-638 30 30FAX: +41(0)61-638 30 40e-mail: [email protected]

United KingdomKROHNE Ltd.Rutherford DrivePark Farm Industrial EstateWellingborough,Northants NN8 6AE, UKTEL.: +44(0)19 33-408 500FAX: +44(0)19 33-408 501e-mail: [email protected]

USAKROHNE Inc.7 Dearborn RoadPeabody, MA 01960TEL.: +1-978 535-6060FAX: +1-978 535-1720e-mail: [email protected]

Other Representatives

Other CountriesKROHNE MesstechnikGmbH & Co. KGLudwig-Krohne-Str.D-47058 DuisburgTEL.: +49(0)203-301-0FAX: +49(0)203-301-389e-mail: [email protected]

Subject to change without notice

Overview_Level_2_en_051027_2_pf.qxp 07.11.2005 15:18 Seite 20