Single Pole (One location) or 3-Way (Multi-location) Scene Capable Incandescent Dimmer Cat. No. VRI1Ø-1L, 1000W (Lighted) 120VAC, 60Hz INSTALLATION INSTRUCTIONS DI-000-VRI10-02A WARNINGS AND CAUTIONS: To be installed and/or used in accordance with appropriate electrical codes and regulations. If you are unsure about any part of these instructions, consult a qualified electrician. To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance. Use with incandescent or 120V halogen fixtures only. Vizia RF + TM dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia +™ or Vizia RF + TM remotes for multi-location dimming. Use only one (1) Vizia RF +™ dimmer in a multi-location circuit with up to 9 coordinating remotes (without LEDs) or up to 4 matching remotes (with LEDs). The remote(s) will turn the light on at the brightness level selected at the dimmer. WARNINGS AND CAUTIONS: Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™). Total minimum load must exceed 40W. Dimmer may feel warm to the touch during normal operation. Recommended minimum wall box depth is 2-1/2”. Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture. Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL. INSTALLING YOUR DIMMER NOTE: Use check boxes when Steps are completed. 2 4 BK RD YL/RD 1 3 5 Coordinating Remote Dimmer 5 2 1 Black Green Red Yellow/Red 4 3 Hot (Black) Neutral (White) Load Dimmer Coordinating Remote (no LEDS) YL/RD YL/RD RD WH RD BK BK Black Do not use for incandescent applications. White Line 120VAC, 60Hz Green Ground Green Ground Tools needed to install your Dimmer Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler 3-Way Wiring with Coordinating Remote (no LEDs) Application: Step 4b Green Ground Hot (Black) Neutral (White) Load Dimmer Black White Line 120VAC, 60Hz Black Yellow/Red Red Insulating Label Single-Pole Wiring Application: Step 4a Black Green Red Yellow/Red Dimmer Insulating Label: This wire is used in 3-way installations only. For single pole installations, do not remove this insulating label. 4 3 2 1 IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box. Step 2 Identifying your wiring application (most common): NOTE: If the wiring in the wall box does not resemble any of these configurations, consult a qualified electrician. 2 4 3 1 2 4 1 5 3 3-Way 1. Line or Load (See important instruction below) 2. Neutral 3. Ground 4. First Traveler – note color 5. Second Traveler – note color Single-Pole 1. Line (Hot) 2. Neutral 3. Ground 4. Load INTRODUCTION Leviton’s Vizia RF + TM components are designed to communicate with each other via Radio Frequency (RF) to provide remote control of your lighting. Using RF technology allows Leviton to provide the greatest signal integrity possible. Each module in Leviton’s Vizia RF + TM component line is a Z-Wave ® enabled device. In a Z-Wave ® network, each device is designed to act as a router. These routers will re-transmit the RF signal from one device to another until the intended device is reached. This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots. The Scene Capable Incandescent Dimmer is compatible with any Z-Wave ® enabled network, regardless of the manufacturer and can also be used with other devices displaying the Z-Wave ® logo. CAUTION: Remember to exercise good common sense when using the Timer features of your remote, especially when scheduling unattended devices. There can be some unexpected consequences if not used with care. For example, an empty coffee pot can be remotely turned on. If that should happen, your coffee pot could be damaged from overheating. If an electric heater is turned on by remote control while clothing is draped over it, a fire could result. DO NOT USE the remote for the control of high power heating appliances such as portable heaters. This device will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID lighting). This includes mercury-vapor, sodium vapor and metal halide lamps. Soft fade ON/OFF Scene capable Two way communication RF reliability No Neutral wire required FEATURES ON/OFF LED and Brightness level LED Ease of installation – No new wiring Compatible with other Z-Wave ® enabled devices Changing the color of your Dimmer: Your device may include color options.To change color of the face, proceed as follows: Line up tabs and press in sides one at a time to attach Push in side at tab to release Installing Dimmer by itself or with other devices If installing Dimmer in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi- device application, proceed as follows: MULTI-DEVICE APPLICATION: In multi-dimmer installations, the reduction of the dimmer’s capacity is required. Refer to the chart for maximum load per dimmer. MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE Cat. No. VRI1Ø 1000W Single 800W Two Devices 650W More than 2 Devices Hot (Black) Neutral (White) Load Dimmer Matching Dimmer Remote (with LEDs) YL/RD Red WH BK Black Black White Yellow/ Red Line 120VAC, 60Hz Green Ground Green Ground Additional Neutral Wire BK RD YL/RD Matching Dimmer Remote 4 3 1 2 5 Dimmer Black Green Red 5 2 1 Yellow/Red 4 3 Step 4c 3-Way Wiring with Matching Remote (w/LEDs) Application: Strip Gage (measure bare wire here or use gage on back of the dimmer) 5/8” (1.6 cm) cut (if necessary) Step 3 Preparing and connecting wires: Make sure that the ends of the wires from the wall box are straight (cut if necessary). Remove insulation from each wire in the wall box as shown. For Single Pole Application, go to Step 4a. For 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b. For 3-Way Matching Remote (with LEDs) Application, go to Step 4c. NOTE: The dimmer must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. WIRING MATCHING REMOTE (wall box with Line Hot connection): Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw. Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler to remote terminal screw marked “BK”. Second Traveler wall box wire from dimmer to remote terminal screw marked “YL/RD” (note wire color). This traveler from the remote must go to the terminal screw on the dimmer marked “YL/RD”. Line Neutral wall box to remote terminal screw marked “WH”. WIRING DIMMER (wall box with Load connection): Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green dimmer lead. Load wall box wire identified (tagged) when removing old switch to Red dimmer lead. First Traveler Line Hot to Black dimmer lead. Remove Red insulating label from Yellow/Red dimmer lead. Second Traveler wall box wire (note color as above) to Yellow/Red dimmer lead. This traveler from the dimmer must go to the terminal screw on the remote marked “YL/RD”. Proceed to Step 5. Step 1 WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring! Remove all inner side sections Do not remove outer side sections WIRE NUT / # OF CONDUCTOR COMBINATION CHART 1- #12 w/ 1 to 3 #14, #16 or #18 2- #12 w/ 1 or 2 #16 or #18 1- #14 w/ 1 to 4 #16 or #18 2- #14 w/ 1 to 3 #16 or #18 For non-standard wiring applications, refer to Wire Nut and Conductor Size Chart WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green dimmer lead. Line Hot wall box wire to Black dimmer lead. Load wall box wire to Red dimmer lead. Yellow/Red dimmer lead should have Red insulation label affixed. NOTE: If insulating label is not affixed to Yellow/Red dimmer lead, use electrical tape to cover. Proceed to Step 5. WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows: NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. Green or bare copper wire in wall box to Green dimmer lead. Line Hot (common) wall box wire identified (tagged) when removing old switch to Black dimmer lead. First Traveler wall box wire to Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “RD”. Remove Red insulating label from Yellow/Red dimmer lead. Second Traveler wall box wire to Yellow/Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “YL/RD”. WIRING COORDINATING REMOTE: Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300ft. Green or bare copper wire in wall box to Green terminal screw. Load wall box wire identified (tagged) when removing old switch to terminal screw marked “BK”. First Traveler wall box wire (note color as above) to terminal screw marked “RD”. This traveler from the remote must go to the Red dimmer lead. Second Traveler wall box wire (note color as above) to terminal screw marked “YL/RD”. This traveler from the remote must go to the Yellow/Red dimmer lead. Remote terminal screw marked “WH” should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked “WH”, use electrical tape to cover. Proceed to Step 5.

Upload: alarm-grid

Post on 26-May-2015

265 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Leviton vri10 1 lz product manual and setup guide

Single Pole (One location) or 3-Way (Multi-location) Scene Capable Incandescent Dimmer

Cat. No. VRI1Ø-1L, 1000W (Lighted) 120VAC, 60Hz

INSTALLATION INSTRUCTIONSDI-000-VRI10-02AWARNINGS AND CAUTIONS:

• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,donotinstalltocontrolareceptacle,fluorescentlighting,amotor-oratransformer-operatedappliance.• Usewithincandescentor120Vhalogenfixturesonly.• Vizia RF +TMdimmersarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleVizia+™orViziaRF+TMremotesformulti-locationdimming.• Useonlyone(1)ViziaRF+™dimmerinamulti-locationcircuitwithupto9coordinatingremotes(withoutLEDs)orupto4matchingremotes(withLEDs).Theremote(s)willturnthe

lightonatthebrightnesslevelselectedatthedimmer.

WARNINGS AND CAUTIONS:• Dimmermaynotoperatewithdiodedlamps(SylvaniaDesigner16™orPhilipsPAR-16™).• Totalminimumloadmustexceed40W.• Dimmermayfeelwarmtothetouchduringnormaloperation.• Recommendedminimumwallboxdepthis2-1/2”.• Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft.• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingfixture.• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.

INSTALLING YOUR DIMMER

NOTE: UsecheckboxeswhenStepsarecompleted.√

2

4

Bk

RDYL/RD

1

3

5

Coordinating Remote Dimmer

5

2

1

Black

Green

Red

Yellow/Red

4

3

hot (Black)

Neutral (White)

Load

DimmerCoordinating Remote (no LEDS)

YL/RD

YL/RD

RD

WhRD

BkBkBlack

Do not use forincandescentapplications.

White

Line 120vAC, 60hz

GreenGround

GreenGround

Tools needed to install your Dimmer

Slotted/PhillipsScrewdriver ElectricalTapePliers Pencil Cutters Ruler

3-Way Wiring with Coordinating Remote (no LEDs) Application:

Step 4b

GreenGround

hot (Black)

Neutral (White)

Load

Dimmer

Black

White

Line 120vAC, 60hz

Black

Yellow/Red

Red

InsulatingLabel

Single-Pole Wiring Application:Step 4a

Black

Green

Red

Yellow/Red

Dimmer

Insulating Label:This wire is used in 3-way installationsonly. For single pole installations, donot remove this insulating label.

4

32

1

IMPORTANT: For3-Wayapplications,notethatoneofthescrewterminalsfromtheoldswitchbeingremovedwillusuallybeadifferentcolor(Black)orlabeledCommon.Tagthatwirewithelectricaltapeandidentifyasthecommon(LineorLoad)inboththedimmerwallboxandremotewallbox.

Step 2 Identifying your wiring application (most common): NOTE:Ifthewiringinthewallboxdoesnotresembleanyoftheseconfigurations,consultaqualifiedelectrician.

2

4

3

1 2

4

1

5

3

3-Way1. Line or Load

(See important instruction below)

2. Neutral3. Ground4. FirstTraveler

– note color5. SecondTraveler

– note color

Single-Pole1. Line (Hot) 2. Neutral 3. Ground 4. Load

INTRODUCTION

Leviton’sVizia RF +TMcomponentsaredesignedtocommunicatewitheachotherviaRadioFrequency(RF)toprovideremotecontrolofyourlighting.UsingRFtechnologyallowsLevitontoprovidethegreatestsignalintegritypossible.EachmoduleinLeviton’sVizia RF +TMcomponentlineisaZ-Wave®enableddevice.InaZ-Wave® network,eachdeviceisdesignedtoactasarouter.Theserouterswillre-transmittheRFsignalfromonedevicetoanotheruntiltheintendeddeviceisreached.Thisensuresthatthesignalisreceivedbyitsintendeddevicebyroutingthesignalaroundobstaclesandradiodeadspots.TheSceneCapableIncandescentDimmeriscompatiblewithanyZ-Wave®enablednetwork,regardlessofthemanufacturerandcanalsobeusedwithotherdevicesdisplayingtheZ-Wave® logo. CAUTION:RemembertoexercisegoodcommonsensewhenusingtheTimerfeaturesofyourremote,especiallywhenschedulingunattendeddevices.Therecanbesomeunexpectedconsequencesifnotusedwithcare.Forexample,anemptycoffeepotcanberemotelyturnedon.Ifthatshouldhappen,yourcoffeepotcouldbedamagedfromoverheating.Ifanelectricheateristurnedonbyremotecontrolwhileclothingisdrapedoverit,afirecouldresult.DO NOT USEtheremoteforthecontrolofhighpowerheatingappliancessuchasportableheaters.Thisdevicewillnotcontrollightingthatisusedwithelectroniclow-voltageandhighfrequencypowersupplytransformers,norhighpressuredischargelamps(HIDlighting).Thisincludesmercury-vapor,sodiumvaporandmetalhalidelamps.

• SoftfadeON/OFF• Scenecapable• Twowaycommunication• RFreliability• NoNeutralwirerequired

FEATURES

• ON/OFFLEDandBrightnesslevelLED

• Easeofinstallation–Nonewwiring

• CompatiblewithotherZ-Wave® enableddevices

Changing the color of your Dimmer:Yourdevicemayincludecoloroptions.Tochangecoloroftheface,proceedasfollows:

Line up tabs and press in sides one at a time to attach

Push in side at tab to release

Installing Dimmer by itself or with other devices

IfinstallingDimmerinasingledeviceapplication,proceedwiththeINSTALLING YOUR DIMMERsection.IfinstallingDimmerinamulti-deviceapplication,proceedasfollows:

MULTI-DEvICE APPLICATION:Inmulti-dimmerinstallations,thereductionofthedimmer’scapacityisrequired.Refertothechartformaximumloadperdimmer.

MAXIMUM LOAD PER DIMMER FOR MULTI-DEvICECat. No.

VRI1Ø 1000W

Single

800W

Two Devices

650W

More than 2 Devices hot (Black)

Neutral (White)

Load

DimmerMatching Dimmer

Remote (with LEDs)

YL/RD

RedWh Bk

Black

Black

White

Yellow/Red

Line 120vAC, 60hz

GreenGround

GreenGround

AdditionalNeutral Wire

Bk

RDYL/RD

Matching Dimmer Remote

4

3

1

2

5

Dimmer

Black

Green

Red

5

2

1

Yellow/Red

4

3

Step 4c 3-Way Wiring with Matching Remote (w/LEDs) Application:

Strip Gage (measure bare wire

here or use gage on back of the dimmer)

5/8”(1.6 cm)cut

(if necessary)

Step 3 Preparing and connecting wires:

• Makesurethattheendsofthewiresfromthewall boxarestraight (cut if necessary).

• Removeinsulationfromeachwireinthewallboxasshown.• For Single Pole Application, go to Step 4a.• For 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b.• For 3-Way Matching Remote (with LEDs) Application, go to Step 4c.

NOTE: ThedimmermustbeinstalledinawallboxthathasaLoadconnection.ThematchingremotemustbeinstalledinawallboxwithaLineHotconnectionandaNeutralconnection.ANeutralwiretothematchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft.WIRING MATChING REMOTE (wall box with Line hot connection):Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)whenremoving

oldswitchandFirstTravelertoremoteterminalscrewmarked“BK”.• SecondTravelerwallboxwirefromdimmertoremoteterminal

screwmarked“YL/RD”(note wire color).Thistravelerfromtheremotemustgototheterminalscrewonthedimmer marked“YL/RD”.

• LineNeutralwallboxtoremoteterminalscrewmarked“WH”.WIRING DIMMER (wall box with Load connection):Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreendimmerlead.• Loadwallboxwireidentified(tagged)whenremovingoldswitchto

Reddimmerlead.• FirstTravelerLineHottoBlackdimmerlead.• RemoveRedinsulatinglabelfromYellow/Reddimmerlead.• SecondTravelerwallboxwire(note color as above)toYellow/Red

dimmerlead.Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked“YL/RD”.

• ProceedtoStep5.

Step 1 WARNING: TO AvOID FIRE, ShOCk, OR DEATh; TURN OFF POWER atcircuitbreakerorfuseandtestthatpowerisoffbeforewiring!

Remove all inner side sections

Do not remove outer side sections

WIRE NUT / # OF CONDUCTOR COMBINATION ChART

1-#12w/1to3#14,#16or#18 2-#12w/1or2#16or#181-#14w/1to4#16or#182-#14w/1to3#16or#18

For non-standard wiring applications, refer to Wire Nut and Conductor Size Chart

WIRING DIMMER:

Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreendimmerlead.• LineHotwallboxwiretoBlackdimmerlead.• LoadwallboxwiretoReddimmerlead.• Yellow/ReddimmerleadshouldhaveRedinsulationlabelaffixed. NOTE:IfinsulatinglabelisnotaffixedtoYellow/Reddimmerlead,

useelectricaltapetocover.• Proceed to Step 5.

WIRING DIMMER:Connect wires per WIRING DIAGRAM as follows:NOTE:WhenusingthecoordinatingremotewithoutLEDs,thedimmercanbeinstalledoneithertheLineorLoadsideofthe3-waycircuit.NOTE: Maximumwirelengthfromdimmertoallinstalledremotescannot exceed300ft.• GreenorbarecopperwireinwallboxtoGreendimmerlead.• LineHot(common)wallboxwireidentified(tagged)whenremovingoldswitch

toBlackdimmerlead.• FirstTravelerwallboxwiretoReddimmerlead(note wire color).Thistraveler

fromthedimmermustgototheterminalscrewontheremotemarked“RD”.• RemoveRedinsulatinglabelfromYellow/Reddimmerlead.• SecondTravelerwallboxwiretoYellow/Reddimmerlead(note wire color).

Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked“YL/RD”.

WIRING COORDINATING REMOTE:Connect wires per WIRING DIAGRAM as follows:NOTE: Maximumwirelengthfromdimmertolastremoteis300ft.• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoterminal

screwmarked“BK”.• FirstTravelerwallboxwire(note color as above)toterminalscrewmarked

“RD”.ThistravelerfromtheremotemustgototheReddimmerlead.• SecondTravelerwallboxwire(note color as above)toterminalscrew

marked“YL/RD”.ThistravelerfromtheremotemustgototheYellow/Reddimmerlead.

• Remoteterminalscrewmarked“WH”shouldhaveWhiteinsulationlabelaffixed.NOTE: Ifinsulatinglabelisnotaffixedtoterminalscrewmarked“WH”,useelectricaltapetocover.

• ProceedtoStep5.

Page 2: Leviton vri10 1 lz product manual and setup guide

Including Scene Capable Dimmer into Z-Wave® Network:

Restore Power: Restorepoweratcircuitbreakeror fuse.Installation is complete.

D)ThePrimaryProgrammer/ControllerwillassignanodeIDnumber(Name)forthismodule.

NOTE: ThisIDnumber(Name)willbestoredinthecontrollerlibrarytobeusedforfuturereference.

NOTE: Youmayeditthenameofthisdeviceatthistime.

E) The dimmer is now installed in the network.

NOTE: IfadimmerhasbeensuccessfullyIncludedinthenetworkandtheusertriestoIncludeitagainwithoutfirstexcludingitfromthenetwork,themodulewillretainthefirstnodeIDithadreceivedandignorethesecond.

Testing your Dimmer prior to mounting in wall box:

LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenefitofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforfiveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchfiveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandfitnessforaparticularpurpose,islimitedtofiveyears.Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.

• Restorepoweratcircuitbreakerorfuse.• PresspaduntillocatorlightisOFF.Lights

shouldturnON.IflightsdonotturnON,presstherighthalfofDIM/BRIGHTbaruntilthelightsbrighten.

If lights still do not turn ON, refer to the TROUBLEShOOTING section.

NOTES:• Ifusinganon-LevitonProgrammer/Controller,

refertotheProgrammer/ControllerinstructionsheetforIncludingadevice.

• IfusingtheVRCPG'sInstallChecklistfeature,godirectlytoStepB.

A)IfusingaLevitonZ-Wave®Programmer/Controller,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.

B)Whilestandingclosetothemodule(approx.2-5ft),pressthecenterbuttonto<Include>deviceinthenetwork.

NOTE:Onlyonedevicemaybeincludedatatime.DO NOTputmultipledevicesintotheInclusionmodeatanytime.

C) WhiletheProgrammer/ControllerisintheInclusionmodeandtheLocatorLEDisONonthedimmer,pushthepushpadtoturnONthedimmer.TheProgrammer/ControllerwillverifyinclusionandthelocatorLEDwillturnOFFonthedimmer.

IfthedimmerisflashingAmberwhileintheInclusionmode,theProgrammer/Controllerisstilltryingtocommunicatewiththedimmer.Waituntilthedevicestopsflashing,thenpresspushpad.

NOTE:IfthelocatorLEDonthedimmerturnssolidRedwhileincluding,therehasbeenacommunicationerror.RefertoTroubleshootingsection. DI-000-VRI10-02A2008©LevitonMfg.Co.,Inc.

ProtectedunderU.S.PatentNumber6,388,399andpatentspending andlicensedunderU.S.PatentsNumbers5,905,442,and5,982,103

Programmer/Controller Cat. No. vRCPG

Menu Button

1 ON

2 ON

3 ON

4 ON

OFF

OFF

OFF

OFF

Center Button

• Lights Flickering - Lamphasabadconnection. - Wiresnotsecuredfirmlyunderterminalscrewsofdimmer

and/orremote. - Localswitch,ON• Light does not turn ON and Locator LED does not turn ON - Circuitbreakerorfusehastripped. - Lampisburnedout. - LampNeutralconnectionisnotwired. - Confirmthatthedeviceisbeingsuppliedfroma120V,60HzAC

sourceONLY. - Confirmthatunitisprogrammedproperly.Repeat“TOINSTALL”

sectiontoverifythatithasbeenincludedintheZ-Wave™network.

• Intermittent dimmer operation - Minimumloadisunder40W. - ConfirmthattheLoadbeingcontrolleddoesnotexceedthe

1000Wdimmerlimit.• Remote does not operate lights - Ensurethattotalwirelengthdoesnotexceed300ft.

TROUBLEShOOTING

For additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at

www.viziaRFplus.com

NOTE:ThelocatorlightwillilluminatewhentheloadisintheOFFpositiontofacilitateaccessinthedark.NOTE:Ifusingthedimmerina3-wayapplication,thelightswillturnONatbrightnesssetondimmer’sDIM/BRIGHTbar.Thelightingcanbecontrolledfromeitherthedimmerortheremotelocation.Push Pad (Default settings) Turn ON from OFF position: Tap–LightsturnONtopresetlevel. PressandHold–LightsturnONtofullbright.Turn OFF from ON position:Tap–LightsturnOFF.

LED Brightness Display

DIM/BRIGhT Bar

Push Pad

Locator Light

OPERATION

Installationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate.

Dimmer Mounting: TURN OFF POWER AT CIRCUIT BREAkER OR FUSE.

Step 7

Step 6

NOTE: ItisveryimportanttoaccuratelyExcludedevicesfromthenetworkwhenmovingorremovingadevicefromaZ-Wave®network.ThisensuresthatallinformationhasbeenremovedfromyourPrimaryProgrammer/Controller’sinformationtableandisnotcountedontobeapartofthemeshnetwork.A)IfusingaLevitonZ-Wave®Programmer/Controller,Cat.No.VRCPG,

presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.

B) Whilestandingclosetothedimmer,pressthecenterbuttonto<Exclude>devicefromthenetwork.WhiletheProgrammer/ControllerisintheExclusionmodeandthelocatorLEDisONonthedimmer,pressthepushpadonthedimmer.TheProgrammer/ControllerwillverifyExclusionandthelocatorLEDwillturnOFFonthedimmer.

IfthedimmerisflashingAmberwhileintheExlusionmode,theProgrammer/Controllerisstilltryingtocommunicatewiththedimmer.Waituntilthedevicestopsflashing,thenpressthepushpad.

Factory Default:Ifyourdimmerisnotresponding,oryouareunabletocontrolitafteryouhavetriedtoInclude/Excludeitmultipletimes,itmaybenecessarytoresetthedimmertoitsoriginalfactorysettings.Toaccomplishthis,proceedasfollows:• Onthedimmer,engageheair-gapswitch(refer to Operation

section)andwait5seconds.PresspushpadbackintoframeandholdpushpaduntilthelocatorLEDturnsAmberandthenturnsRed.Thedimmerisnowreset.Oncethedimmerisreset,itwillbenecessarytoRe-Includeittoanetworkbeforeitcanbeused.

CAUTION:SETTINGADEVICETOAFACTORYDEFAULTDOESNOTEXCLUDETHATDEVICEFROMANETWORK.THEEXCLUSIONPROCEDUREMUSTSTILLBEFOLLOWEDTOREMOVETHEDEVICEFROMTHEPRIMARYCONTROLLER’SINFORMATIONTABLE.FAILURETODOSOMAYRESULTINASYSTEMTHATISSLOWTORESPOND,ORMAYFAILTORESPONDTOSOMEDEVICES.

Step 9 Excluding Dimmer from Network:

Step 8

NOTE: Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice.

• Positionallwirestoprovideroominoutletwallboxfordevice.

• Ensurethattheword“TOP”isfacingupondevicestrap.

• Partiallyscrewinmountingscrewsinwallboxmountingholes.

Step 5

A-2) TheLocatorLEDwillblink2timespersecondtoindicatethedeviceisinProgramModeA-2, Minimum Brightness Level. TochangetheMinimum Brightness Levelfrom1-50%,usetheDIM/BRIGHTBar.Thelightoutputwillreflecttheminimumbrightnesslevelselected.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,A-3.

A-3) TheLocatorLEDwillblink3timespersecondtoindicateProgramMode A-3, Preset ON Level.TochangethecurrentPreset ON Levelfrom1-100%,usetheDIM/BRIGHTBar.Ifthisfeatureisnotdesired,pressandholdthelefthalfoftheDIM/BRIGHTBar(v) untilnoLEDislit(defaultsetting).BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewillexitProgrammingModeA.

Program Mode BTo enter Program Mode B:PressandholdthePushPadandthenthelefthalfofthe DIM/BRIGHTBar(v)for5secondsuntiltheLocatorLEDandrightmostLED(LED7)begintoblink.B-1) UponreleasingthePushPadandthelefthalfofthe

DIM/BRIGHTBar(v),theLocatorLEDwillcontinuetoblinkoncepersecondindicatinghedimmerisinProgramModeB-1, ON Fade Rate.TochangetheON Fade Rate,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetlevelaccordingtoChart B.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,B-2.

B-2) TheLocatorLEDwillblink2timespersecondtoindicateProgramMode B-2, OFF Fade Rate.TochangetheOFF Fade Rate,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetlevelaccording to Chart B.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,B-3.

LED BrightnessDisplay

1 2 3 4 5 6 7

Definition of A ModesA-1) EnergySave:Setsthemaximumbrightnesslevelforenergy

savings.A-2) MinimumBrightnessLevel:Setstheminimumdimminglevel.A-3) PresetONLevel:Setstheturnonbrightnesslevelregardlessof

theprevioussetlightlevel(formerlyDimLock).Definition of B ModesB-1) ONFadeRate:Setstheamountoftimeinsecondsittakesthe

lightstoturnONtomaximumbrightness.B-2) OFFFadeRate:Setstheamountoftimeinsecondsittakesthe

lightstoturnOFFfrommaximumbrightness.B-3) LEDOptions:SetsthetimeperiodinsecondstheLocatorLED

andBrightnessdisplaywillstayonbeforeextinguishing.

Definition of LEDsLeftmostLED=LED1RightmostLED=LED7NOTES:• Thedevicewillexitprogramming

modeafter3minutesofinactivity.• Pressingthepushpadatanytime

duringprogrammingwilladvancethedevicetothenextprogrammingmode.

ADvANCED PROGRAMMING FEATURES

Program Mode ATo enter Program Mode A:PressandholdthePushPadandthentherighthalfofthe DIM/BRIGHTBar(^)for5secondsuntiltheLocatorLEDandleftmostLED(LED1)begintoblink.A-1) UponreleasingthePushPadandtherighthalfofthe

DIM/BRIGHTBar(^),theLocatorLEDwillcontinuetoblinkoncepersecondandtherightmostLEDwillilluminatetodisplaythedeviceisinProgramModeA-1, Energy Save.Thedefaultenergysavemodeis100%i.e.fullbright.Tochangethe Energy Savelevel,usetheDIM/BRIGHTBartomovethecorrespondingLEDtothedesireddiscretepresetlevelaccording to Chart A.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,A-2.

B-3) TheLocatorLEDwillblink3timespersecondtoindicateProgramMode B-3, LED Options.TochangetheLED Optionssettings,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetsettingaccordingtotheChart B-3.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewillexitProgrammingModeB.

LED

LED 1

LED 2 (Default)

LED 3

LED 4

LED 5

LED 6

LED 7

FADE ON

0 seconds (instant)

0.5 seconds

1.5 seconds

3.0 seconds

6.0 seconds

10 seconds

25 seconds

0 seconds (instant)

0.5 seconds

1.5 seconds

3.0 seconds

6.0 seconds

10 seconds

25 seconds

FADE OFF

Chart B

When indicatorlight is at LED #

7654321

Light output is at

100%97%95%90%85%80%75%

Energy consumptionsavings amounts to

0%5%8%

11%14%17%20%

Chart A Chart B-3

LED

LED 1

LED 2

LED 3

LED 4

LED 5

LED 6

LED 7

LOCATOR LED TIMEOUT

Active

Active

Active

Active

Turns off 5 sec. after use

Turns off 5 sec. after use

Turns off 5 sec. after use

LED BRIGHTNESS DISPLAY OPTIONS

Active

Turns off 5 sec. after use

Active

Turns off 5 sec. after use

LED Bar active

LED Bar turns off 5 sec. after use

LED Bar turns off 5 sec. after use

vRCPG Programmer/

Controller

NOTE: Remotemustbeincloseproximitytodimmerwhenincludinginnetwork.

DIM/BRIGhT Bar BRIGhTEN:PressrighthalfofDIM/BRIGHTBar–Lightsbrightentodesiredlevel.DIM:PresslefthalfofDIM/BRIGHTBar–Lightsdimtodesiredlevel. IfyoucontinuetoholdthelowerhalfoftheDIM/BRIGHTBar,thelightswillDIMtominimumlevelandthenturnOFF. NOTE:WhenlightsareOFFyoucanchangethelightlevelthatthelightswillturnONtousingtheDIM/BRIGHTBar.Ifthereisapoweroutage,whenthepowerisrestoredthelightswillreturntothelastsettingbeforethepowerinterruption.Air-Gap Switch:Onthedimmeronly,engage theair-gapswitchbygentlypressingthetopofthepushpaduntilthebottomliftscompletelyoutoftheframeandaclickisheard (refer to Figure).LEDswillturnOFF. Thiswillcutpowertothefixturetoreplacethebulb.Afterservicingiscomplete,pushthepushpadbackfornormaloperation.Cleaning: Cleanwithadampcloth.DO NOT usechemicalcleaners.

Gently press top of push pad

ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:• ReorientorrelocatethereceivingAntenna.• Increasetheseparationbetweentheequipmentandthe

receiver.• Connecttheequipmentintoanoutletonacircuitdifferentfrom

thattowhichthereceiverisconnected.• Consultthedealeroranexperiencedradio/tvtechnicianfor

help.