lg multi split air conditioners 2010 - thermofrost...

36
uk.lgeaircon.com LG Multi split Air Conditioners 2010 More comfort. Less impact.

Upload: lethien

Post on 29-Mar-2018

256 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

uk.lg

eairc

on.c

om

LG Multi split Air Conditioners 2010More comfort. Less impact.

Page 2: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Comfort that doesn’t cost the Earth

A Multi split system makes it easy to condition multiple rooms. Using your choice of units from our indoor range you can program different temperatures for each room. All with the use of just one outside unit. It’s a cost-effective way of providing a comfortable environment.

We all want to be more comfortable. And there’s no reason we shouldn’t have a comfortable workplace and living area too. But can we afford to compromise the environment for our own wellbeing? There must be a balance. That’s why we’ve designed our commercial air conditioning range to bring you the benefits you need in a way that’s kinder to the environment.

It’s the same with all of our products. We manufacture everything in line with our ‘Eco-Design’ principle. It ensures the environmental impact of our products is as low as possible. From production to disposal. We’ve also invested heavily in research and development to make our products some of the most energy efficient in the world. Because even a small change to efficiency can have a big impact on the environment.

Our air conditioning range uses eco-friendly refrigerants so they emit no ozone depleting pollutants. It means you can have air conditioning with less impact on the environment. You can control temperature and air quality in a way that doesn’t cost the Earth. And because our units are so energy efficient, they can help slash your energy bills too. It pays to be green.

LG air conditioning units require very little upkeep. They’re safe, easy to manage and reliable.

Energy efficiency in cooling mode:

Energy efficiency in heating mode:

“Now you can have air conditioning with

less impact on the environment. You can

control temperature and air quality in a

way that doesn’t cost the Earth.”

Multi split

Page 3: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Contents

Multi split features 02

Outdoor unit specifications 08

Wall mounted unit specifications 12

Ceiling cassette unit specifications 14

Ceiling concealed duct unit specifications 16

Ceiling and floor unit specifications 18

Console unit specifications 19

Accessories 20

Output tables 22

LG Air Conditioners 2010 01

Page 4: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Multi split

A system designed for savings

High COP & energy saving Highly efficientOur new Inverter multi-models are among the most energy efficient air conditioning units in the world. They use a BLDC fan and motor, as well as highly efficient heat exchangers to slash energy consumption. That means lower energy bills and a smaller carbon footprint.

The annual carbon savings prompted by using an LG Inverter AC system instead of a non-inverter system is equivalent to the amount of carbon absorbed 138 big cone pine trees.

1) Based on research by the KFRI (Korea Forest Research Institute) into annual power savings (using air conditioning 4 hours a day for 365 days).2) 37% energy saving is compared to use of LG non-inverter model.

DC Inverter technologyCutting-edge DC Inverters make for quieter and more economic air conditioning. They monitor the power sent to your unit based on what’s needed to cool or heat your room. So you only use the energy you need. Sine wave and PFC technology reduces vibration and prompts a more even energy consumption, improving energy.

The images show the performance of Inverter models using PFC (Power Factor Correction) and sine wave control technology compared to conventional units.

Loss Full range

DC280V

VI

Partial switching

VI

Full range Sine wave switching

DC 380V(Boost up)

• Sine wave control in BLDC compressor

Sine waveRectangle wave

Loss Full range

DC280V

VI

Partial switching

VI

Full range Sine wave switching

DC 380V(Boost up)

• PFC control in power input

Using LG Inverter AC is same

as planting 138 big cone pines.

Using LG Inverter AC 138 big cone pines

=

MU3M19

4.4

4.8

4.0

4.3

4.0

4.6 4.64.1

3.8

4.6

MU3M21 MU4M25 MU4M27 MU5M30

Cooling

CO

P

Heating

LGH-Inverter

3.72

4.46

3.704.16

3.61

4.12

A Company B Company

CoolingHeatingUsing LG Inverter AC is same as planting 138 big cone pines.

EnergySaving37%

Page 5: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

A greener spinWe’ve fine-tuned every part of our units to help make them more efficient. The BLDC fan motor that drives the fan cuts energy consumption by up to 35% when spinning at full velocity.

0200

Motor Speed(rpm)

DC motor

AC motorApprox40%

increase

Eff

icie

ncy(

%)

300 400 500 600 700 800 900 1000

20

40

60

80

100

Approx20%

increase

Minimal oil circulation

Highly efficient motor

High compression efficiency

1

2

Low vibration for quiet operation

Highly reliable

4

5

1

2

4

5

3

Powerful BLDC compressorOur inverter units feature a BLDC compressor. It’s part of what makes our units so efficient and uses strong magnets to give more power for less energy consumption. As well as being more efficient, it has many advantages over traditional AC inverter units.

BLDC Fan motor

Energy Efficiency

Heat exchangers that are more efficient

Height : 6%

Length : 8%

Heat exchange rate(%)

Corrugate fin Wide louver fin기존 루버핀

전열성능(%)

고효율 와이드 루버핀 -15℃ 1℃ 7℃ 35℃외기온도

에너지 효율 (COP)

100

123128

0

+5%+8% +7%

+2%

100% 100%

128%123%

난방

난방

냉방

냉방

와이드 루버 골드핀

일반 루버핀

CoolingC

C

H

H C H

Condensing

Evaporation

Condensing

Evaporation

Heating

We’ve streamlined the shape of our fan blades for air conditioning that’s quieter and more efficient. Each blade is more aerodynamic with a sharper front edge and a smoother rear edge. It cuts through the air quicker which means it requires less energy to keep spinning.

Static Pressure

Before After

Axial fan

1

2

3

Leading edge

Trailing edge

Prevent oil discharge We’ve improved the oil circulation in our compressors so the level of oil is maintained, even at high Hz.

Adopt Oil Separate & Optimize Oil Path

Wide louvre fins• 28% improvement in

heat exchange• Anti-corrosion

treatment (Gold FinTM)

LG Air Conditioners 2010 02 _03

3

Page 6: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Multi split

If you are based in a new building it will be better insulated and place less demand on an air conditioning system. Small rooms are also much easier to heat or cool. We have a range of air conditioners that run off just 2.1kw. They’re perfect for bringing high quality air conditioning to small or well-insulated spaces. And because they run off minimal power, they will help keep your energy costs low.

Extreme temperatures? No problemOur units are resilient and work efficiently even in extreme weather conditions. Heating functions fully in temperatures as low as -15oC and cooling works in temperatures as high as 43oC. So you won’t be without your air conditioning when you need it most.Sometimes rooms need cooling when the outdoor temperature is low, the BLDC compressor and BLDC fan adjust airflow and volume of the system. It means that your room will remain cool, even with outdoor temperatures as low as -10oC.

Smaller energy consumption for smaller spaces

www.lgeaircon.com

2.5 kW

2.5 kW

LG Air Conditioner

LG Recomend the 1.5kWAir Conditioner for the First

www.lgeaircon.com

2.5 kW

2.5 kW

LG Air Conditioner

LG Recomend the 1.5kWAir Conditioner for the First

www.lgeaircon.com

2.5 kW

2.5 kW

LG Air Conditioner

LG Recomend the 1.5kWAir Conditioner for the First

Ind

oo

r Te

mp

(˚C)

Outdoor Temp(˚C)

10

18

30

32

-15

21

-10 21 35 43

Cooling

Heating

Low AmbientControl

Indoor capacity combinations

8.8kW

2.6kW

2.6kW

3.5kW

3.5kW160%

MaxCombination

7.0kW

2.6kW

2.6kW

2.6kW

3.5kW163%

MaxCombination2.6kW

2.6kW

3.5kW5.3kW

167%Max

Combination

Page 7: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

LG Air Conditioners 2010 04 _05

The Multi with the mostOur outdoor FM56AH is an advanced unit that makes it easy to connect air conditioning all around your building. It supports a long piping length and can power Indoor units as far away as 70m, up to a height of 30m. So if you want to control the climate of a multi-storey building, you no longer need an Outdoor unit on every floor.

50m

Outdoor unit

Distributor

A

L1

L2L3

Indoor unit

Outdoor unit

Indoor unit

15m

30m

*Multi piping unit

Total

Max / Room

Maximum elevation

(Indoor-Outdoor)

(Indoor-Indoor)

5025

157.5

7025

157.5

7525

157.5

8525

157.5

Piping length(m) 19k 25k 30k 40k

Total pipe (A+L1+L2+L3)

Main pipe(A)

Total branch pipe (L1+L2+L3)

Each branch pipe

Maximum elevation

Indoor-Outdoor (B)

Indoor-Indoor (C)

100505015

3015

135558015

3015

145559015

3015

Piping length(m) 40k 48k 56k

*Distributor box unit

For less than 10 floors

Max 70m pipe run / 30m elevationAllows removal of the Outdoor unit from a balcony to the car park or roof.

• Easy to get approval from council• Avoid safety issues

Page 8: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Multi split

A system for the modern worldImproved low noiseThe Inverter technology, the BLDC Motor technology, and LG’s unique new Skew Fan technology have achieved the world’s lowest noise level of 19dB. Thus, the Sleep mode will allow pleasant sleeping.

Noise Level

Outdoor 45dB

Indoor 19dB

LG Air Conditioner

19dB

Woods26dB

Library33dB

Conventional Inv.

Conventional On / Off

22dB

32dB

Sshh... Our air conditioning is super-quietThe days of noisy air conditioning are over. We’ve combined sound-reducing technolo-gies and changed the shape of our fans for air conditioning that’s extremely quiet. You’ll hardly hear it.

Our units are quick and easy to install. Quick access to the internal components means that as well as being easy to fit, your unit will be easy to service too.

Easy to install, easy to service

3 screws

Ez SVC

1. Inner SVC valve- The piping that connects the external unit to the rest of the system can be formed in any direction, giving you complete freedom in where you position your unit.

4 way1 way

2. Convenient moving handle- Fitted hand grips for easy transportation

3. Compact Design & Ez SVC- Space-saving design means the unit is easy to manoeuvre- Easy access to internal components with an easily detachable front panel

Command

Sensor reading

Air Conditioner

Home Server

Internet

Digital Door Lock Emergency Switch Motion Detect Sensor

Living Room Light Kitchen TV Door Phone

Remote Switch

Smart phone Solution for Operation monitoring & Trouble shootingSmart phone connectionWhen faults have occurred, you can see the Error code during the check of indoor and outdoor units, select the Error code, and find solutions to each problem through Q&A. It is like the trouble shooting guide book embedded in the smart phone. Wired Bluetooth Module

LG MV software on Smart phone

RS-232

Operation Monitoring Troubleshooting on Smart phone •Select

communication method and language

•Checktheinstallation status

•Compressoroperation status

•Checktheindoorunit status

1. Select Error Code

2. Easy Process

3. Service Action

Page 9: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

LG Air Conditioners 2010 06 _07

What’s your perfect combination?Choose from a wide range of indoor and outdoor units (up to 16.4kw) to create the perfect system for your environment. Not sure what to choose? Talk to us.

Free combination indoor units

Note: * choose your perfect finish * Blue (B) * Silver (V) * Red (E) * Gold (G) * White Silver (H) * Mirror (R) Gallery (1)

Product

Capacity Range

(kBtu/kW)

7/2.1

9/2.6

12/3.5

18/5.3

24/7.0

Ceiling Concealed Duct

Slim Duct High

Ceiling & Floor Unit

Console

Ceiling Cassette

Gallery4-way

Wall Mounted Unit

Mirror

MS07AH N40•

MS09AH N40•

MS12AH N40•

MS18AH N50•

MS24AH N50•

MT10AH NR0•

MT12AH NR0•

MT18AH NQ0•

MT24AH NP0•

CC07AW* NE3•

CC09AW* NE3•

CC12AW* NE3•

CC18AW* N83•

CC24AW* N83•

MA09AH1 NF1•

MA12AH1 NF1•

CQ09 NA0•

CQ12 NA0•

CQ18 NA0•

MB09AHL N12•

MB12AHL N12•

MB18AHL N22•

MB24AHL N22•

MB18AH NH0•

MB24AH NH0•

MV09AH NE0•

MV12AH NE0•

MV18AH NB0•

MV24AH NB0•

Wall Mounted

Type

Category

Model

CapacityKW(C/H)

Max.Indoor units

Phase

Multi Piping DB Box Unit

MU5M30 U40

8.8/10.1

5

FM48AH U33FM56AH U33

15.5/16.416.7/17.9

89

MU3M19 UE0MU4M25 UE0 MU5M40 UH0 FM40AH UH5

1ø 1ø 1ø 1ø 1ø

5.3/6.37.0/8.4 11.7/13.5 11.7/13.5

34 5 7

Page 10: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Specifications: outdoor units

Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor temperature 27°C (80.6°F) DB /19°C (66.2°F) WB - Outdoor temperature 35°C (95°F) DB /24°C (75.2°F) WB Heating: - Indoor temperature 20°C (68°F) DB / 15°C(59°F) WB - Outdoor temperature 7°C (44.6°F) DB / 6°C (42.8°F) WB Piping length - Interconnecting piping length 7.5m - Level difference of zero. 2. * : See Combination tables at the back of the brochure. 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two Indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

Nominal capacity* Cooling Btu/h (Min~rated~max) kW Heating Btu/h kW Nominal input* Cooling kW (Min~rated~max) Heating kW Energy label Testing combination

Running current Cooling A (Min~rated~max) Heating A Power supply Ø / V / Hz Dimensions W*H*D mm(inch) Net weight kg(lbs) Max. Number of connectable Indoor units Refrigerant Charge (at 7.5m) g(oz) Air flow rate CMM(CFM) Sound level Sound pressure at 1m dB(A)+3 Piping connections Liquid(ø) mm(inch) Gas(ø) mm(inch) Max. interunit Total of each room m Piping length For one room m Max. Elevation Indoor unit~Outdoor unit m Indoor unit~Indoor unit mRecommended Fuse A

MU3M19 UE0 MU4M25 UE0

 4,600~18,000~21,600 1.35~5.3~6.33

4,800~21,600~24,8001.41~6.3~7.27

  0.38~1.20~2.37 0.45~1.31~2.48

 A/A

 CS07AQ NB0 × 3EA

1.7~5.23~10.3 2.0~5.7~10.8

 1 / 220~240 / 50 870×808×320 (34.3×31.8×12.6)

58(128)3

2100(74.1)53(1872)

52 6.35(1/4)×3EA 9.52(3/8)×3EA

5025157.520

     6,300~24,000~29,0001.85~7.03~8.5

 7,560~28,800~32,000 2.22~8.44~9.38  0.72~1.75~3.09 0.88~1.83~3.10

 A/A

 CS07AQ NB0 × 4EA

3.1~7.65~13.4 3.8~8.0~13.5

 1 / 220~240 / 50 870×808×320 (34.3×31.8×12.6)

61(134)4

2300(81.13)53(1872)

52 6.35(1/4)×4EA 9.52(3/8)×4EA

7025157.525

• MU3M19 UE0• MU4M25 UE0

148O

utdoor unit - DC Inverter SINGLE A (1Ø

, 3Ø)

5CSL0-05ADim

ensions

1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

Note

AUUW246D[UU24W UED]AUUW306D[UU30W UED]

Model namePower Supply

Cooling CapacityHeating Capacity

PipingConnections

LiquidGas

Ø/V/HzkWkWmmmm

AUUW246D[UU24W UED]1/ 220~240 / 50

9.5215.88

AUUW306D[UU30W UED]1/ 220~240 / 50

9.5215.88

Simultaneous operationRefer to combination table

OUTDOOR UNIT

No.123456

krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover

(Unit:mm)

Multi split _

Model

Page 11: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

LG Air Conditioners 2010 08 _09

Specifications: outdoor units

• MU5M30 U40

Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor temperature 27°C (80.6°F) DB /19°C (66.2°F) WB - Outdoor temperature 35°C (95°F) DB /24°C (75.2°F) WB Heating: - Indoor temperature 20°C (68°F) DB / 15°C(59°F) WB - Outdoor temperature 7°C (44.6°F) DB / 6°C (42.8°F) WB Piping length - Interconnecting piping length 7.5m - Level difference of zero. 2. * : See Combination tables at the back of the brochure. 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two Indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

Outdoor unit - DC Inverter SING

LE A (1Ø, 3Ø

)153

5CSL0-05ADim

ensions

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: U4

OUTDOOR UNIT

AUUW216DH [UU21WH U4D]AUUW246DH [UU24WH U4D]

Gas pipe connection

Part Name

Air discharge grille

Liquid pipe connection

Earth screwPower & transmission connection

5

Item No.

2

43

1Remark

Technical Specification

1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

Note

AUUW216DH [UU21WH U4D]1/ 220~240 / 50

9.5215.88

AUUW246DH [UU24WH U4D]1/ 220~240 / 50

9.5215.88

Model namePower Supply

Cooling CapacityHeating Capacity

PipingConnections

LiquidGas

Ø/V/HzkWkWmmmm

Simultaneous operationRefer to combination table

Outdoor unit - DC Inverter SING

LE A (1Ø, 3Ø

)153

5CSL0-05ADim

ensions

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: U4

OUTDOOR UNIT

AUUW216DH [UU21WH U4D]AUUW246DH [UU24WH U4D]

Gas pipe connection

Part Name

Air discharge grille

Liquid pipe connection

Earth screwPower & transmission connection

5

Item No.

2

43

1Remark

Technical Specification

1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

Note

AUUW216DH [UU21WH U4D]1/ 220~240 / 50

9.5215.88

AUUW246DH [UU24WH U4D]1/ 220~240 / 50

9.5215.88

Model namePower Supply

Cooling CapacityHeating Capacity

PipingConnections

LiquidGas

Ø/V/HzkWkWmmmm

Simultaneous operationRefer to combination table

Model Nominal capacity* Cooling Btu/h (Min~rated~max) kW Heating Btu/h kW Nominal input* Cooling kW (Min~rated~max) Heating kW Energy label Testing combination

Running current Cooling A (Min~rated~max) Heating A Power supply Ø / V / Hz Dimensions W*H*D mm(inch) Net weight kg(lbs) Max. Number of connectable Indoor units Refrigerant Charge (at 7.5m) g(oz) Air flow rate CMM(CFM) Sound level Sound pressure at 1m dB(A)+3 Piping connections Liquid(ø) mm(inch) Gas(ø) mm(inch) Max. interunit Total of each room m Piping length For one room m Max. Elevation Indoor unit~Outdoor unit m Indoor unit~Indoor unit mRecommended Fuse A

MU5M30 U40 MU5M40 UH0

6,300~30,000~36,0001.85~8.80~10.55

7,560~34,500~41,4002.22~10.1~12.10.72~2.31~3.160.88~2.19~3.87

A/A

 CS07AQ NB0 × 5EA

3.1~10.1~13.73.8~9.6~16.8

1/220~240/50950×834×330(37.4×32.8×13.0)

67(147.7)5

3,300(116.4)60(2119)

536.35(1/4)×5EA9.52(3/8)×5EA

7525157.525

(Unit:mm)

(Unit:mm)

• MU5M40 UH0

169

Product dataOutdoor units_Multi piping type

Part 2 Product data

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: UH

OUTDOOR UNIT

A5UW406FA3 [FM38AH UH3]

Gas pipe connection

Part Name

Air discharge grille

Liquid pipe connection

Earth screwPower & transmission connection

5

No.

2

43

1Remark

Heating Capacity

Cooling Capacity

Power supply

Liquid(Ø)Gas(Ø)

PipingConnections

mm(inch)

mm(inch)6.35(1/4)9.52(3/8)

kW/V/Hz

kWBtu/h

Btu/h

Ø 1 / 220-240 / 50

11.740,000

13.546,000

Technical Specification

Note

5

1135

1165

308

565

273

520

900550

370

395

15

175

4

370

7

6

1

Main service valve(Liquid)

Main service valve(Gas)

6

7

50*4

=200

148

50

50

3

2

1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.5. When pumping down the system, use main service valve. When you are installing the system, not used valve should be closed by cap that equipped from factory.

[Unit : mm]

1135

1165

308

565

273

520

900550

370

395

15175

370

50*4

=200

148

50

50

[Unit : mm]

169

Product dataOutdoor units_Multi piping type

Part 2 Product data

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: UH

OUTDOOR UNIT

A5UW406FA3 [FM38AH UH3]

Gas pipe connection

Part Name

Air discharge grille

Liquid pipe connection

Earth screwPower & transmission connection

5

No.

2

43

1Remark

Heating Capacity

Cooling Capacity

Power supply

Liquid(Ø)Gas(Ø)

PipingConnections

mm(inch)

mm(inch)6.35(1/4)9.52(3/8)

kW/V/Hz

kWBtu/h

Btu/h

Ø 1 / 220-240 / 50

11.740,000

13.546,000

Technical Specification

Note

5

1135

1165

308

565

273

520

900550

370

395

15

175

4

370

7

6

1

Main service valve(Liquid)

Main service valve(Gas)

6

7

50*4

=200

148

50

50

3

2

1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.5. When pumping down the system, use main service valve. When you are installing the system, not used valve should be closed by cap that equipped from factory.

[Unit : mm]

1135

1165

308

565

273

520

900550

370

395

15

175

370

50*4

=200

148

50

50

[Unit : mm]9,600~40,000~46,000

2.8~11.7~13.511,040~46,000~51,000

3.2~13.5~15.01.1~3.63~4.651.4~3.65~4.84

A/A

MS09AH N40 × 5EA

6.2~16.0~20.06.9~16.4~20.51/220~240/50

900×1165×370(35.4×45.8×14.5)95(209)

54,000(141.1)53(1872)×2

586.35(1/4)×5EA9.52(3/8)×5EA

8525157.530

169

Product dataOutdoor units_Multi piping type

Part 2 Product data

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: UH

OUTDOOR UNIT

A5UW406FA3 [FM38AH UH3]

Gas pipe connection

Part Name

Air discharge grille

Liquid pipe connection

Earth screwPower & transmission connection

5

No.

2

43

1Remark

Heating Capacity

Cooling Capacity

Power supply

Liquid(Ø)Gas(Ø)

PipingConnections

mm(inch)

mm(inch)6.35(1/4)9.52(3/8)

kW/V/Hz

kWBtu/h

Btu/h

Ø 1 / 220-240 / 50

11.740,000

13.546,000

Technical Specification

Note

5

1135

1165

308

565

273

520

900550

370

395

15

175

4

370

7

6

1

Main service valve(Liquid)

Main service valve(Gas)

6

7

50*4

=200

148

50

50

3

2

1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.5. When pumping down the system, use main service valve. When you are installing the system, not used valve should be closed by cap that equipped from factory.

[Unit : mm]

1135

1165

308

565

273

520

900550

370

395

15175

370

50*4

=200

148

50

50

[Unit : mm]

Page 12: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Multi split _Specifications: outdoor units

• FM40AH UH5

Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor temperature 27°C(80.6°F) DB /19 °C(66.2°F) WB - Outdoor temperature 35°C(95°F) DB /24°C(75.2°F) WB Heating: - Indoor temperature 20°C(68°F) DB / 15°C(59°F) WB - Outdoor temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB Piping length - Main piping 5m, Branch piping 5m - Level difference of zero. 2. * : See Combination tables at the back of the brochure 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two Indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

335

Product dataOutdoor units_Distributor type(1Ø)

Part 2 Product data

2.2.5 Dim

ensions

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: UH

OUTDOOR UNIT

A7UW406FA3[FM40AH UH3]

Gas pipe connection

Part Name

Air discharge grille

Liquid pipe connection

Earth screwPower & transmission connection

5

No.

2

43

1Remark

Heating Capacity

Cooling Capacity

Power supply

Liquid(Ø)Gas(Ø)

PipingConnections

mm(inch)

mm(inch)9.52(3/8)

19.05(3/4)

kW/V/Hz

kWBtu/h

Btu/h

Ø

40,000

46,000

1 / 220-240 / 50

11.7

13.5

Technical Specification

5

1135

1165

308

565

273

520

8012

4

900550

370

395

15

175

3

2

65

4

370

Note1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

1

1) Outdoor units

[Unit : mm]

1135

1165

308

565

273

520

8012

4

900550

370

395

15

175

65

370

[Unit : mm]

Model9,600~40,000~46,000

2.8~11.7~13.511,040~46,000~51,000

3.2~13.5~15.01.1~3.63~4.651.4~3.65~4.84

A/A

CS09AH NB0 × 7EA

6.2~16.0~20.06.9~16.4~20.51/220~240/50

900×1165×370(35.4×45.8×14.5)95(209)

74000(141.1)53(1872) × 2

589.52(3/8)19.05(3/4)

100

505015301530

Nominal capacity* Cooling Btu/h (Min~rated~max) kW Heating Btu/h kW Nominal input* Cooling kW (Min~rated~max) Heating kW Energy label Testing combination

Running current Cooling A (Min~rated~max) Heating A Power supply Ø / V / Hz Dimensions W*H*D mm(inch) Net weight kg(lbs) Max. Number of connectable Indoor units Refrigerant Charge (at 5m) g(oz) Air flow rate CMM(CFM) Sound level Sound pressure at 1m dB(A)+3 Piping connections Liquid(ø) mm(inch) Gas(ø) mm(inch) Max. interunit Total Piping m Piping length (Main+Total Branch) Main Piping m Total Branch Piping m Each Branch Piping m Max. Elevation Indoor unit~Outdoor unit m Indoor unit~Indoor unit mRecommended Fuse A

FM40AH UH5

(Unit:mm)

11,400~52,800~58,0003.3~15.5~17.0

12,768~56,000~59,0003.7~16.4~17.29

0.84~4.69~5.351.30~4.43~5.58

A/AMS07AH N40 × 5EAMS09AH N40 × 3EA

3.9~21.1~23.26.9~22.6~25.01/220~240/50

950×1380×330 (37.4×54.3×13.0)108(238)

84800(169.3)60(2,119) × 2

589.52(3/8)19.05(3/4)

135

558015301540

13,800~57,000~63,2004.0~16.7~18.52

15,456~61,000~64,0004.5~17.9~18.751.0~4.96~5.651.25~4.62~5.70

A/A

MS09AH N40×8EA

4.6~21.7~24.07.4~22.4~26.01/220~240/50

950×1380×330 (37.4×54.3×13.0)108(238)

94800(169.3)60(2,119) × 2

599.52(3/8)19.05(3/4)

145

559015301540

• FM48AH U33• FM56AH U33

336

Product dataOutdoor units_Distributor type(1Ø)

Part 2 Product data

1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: U3

OUTDOOR UNIT

A8UW486FA3[FM48AH U33]A9UW566FA3[FM56AH U33]

Part Name

Air discharge grilleGas pipe connection

Liquid pipe connection

No.

2

3

1Remark

Technical Specification

Note

Supporter

Heating Capacity

Cooling Capacity

Power supplyModel Name

Liquid(Ø)Gas(Ø)

PipingConnections

mm(inch)

mm(inch)

kW

kWBtu/h

Btu/h

Ø/V/HzA8UW486FA3[FM48AH U33] A9UW566FA3[FM56AH U33]

1 / 220-240 / 5015.5

52,80016.4

56,0009.52(3/8)

19.05(3/4)

1 / 220-240 / 5016.7

57,00017.9

61,0009.52(3/8)

19.05(3/4)

[Unit : mm] [Unit : mm]

FM48AH U33 FM56AH U33

(Unit:mm)

335

Product dataOutdoor units_Distributor type(1Ø)

Part 2 Product data

2.2.5 Dim

ensions

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: UH

OUTDOOR UNIT

A7UW406FA3[FM40AH UH3]

Gas pipe connection

Part Name

Air discharge grille

Liquid pipe connection

Earth screwPower & transmission connection

5

No.

2

43

1Remark

Heating Capacity

Cooling Capacity

Power supply

Liquid(Ø)Gas(Ø)

PipingConnections

mm(inch)

mm(inch)9.52(3/8)

19.05(3/4)

kW/V/Hz

kWBtu/h

Btu/h

Ø

40,000

46,000

1 / 220-240 / 50

11.7

13.5

Technical Specification

5

1135

1165

308

565

273

520

8012

4

900550

370

395

15

175

3

2

65

4

370

Note1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

1

1) Outdoor units

[Unit : mm]

1135

1165

308

565

273

520

8012

4

900550

370

395

15

175

65

370

[Unit : mm]

335

Product dataOutdoor units_Distributor type(1Ø)

Part 2 Product data

2.2.5 Dim

ensions

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: UH

OUTDOOR UNIT

A7UW406FA3[FM40AH UH3]

Gas pipe connection

Part Name

Air discharge grille

Liquid pipe connection

Earth screwPower & transmission connection

5

No.

2

43

1Remark

Heating Capacity

Cooling Capacity

Power supply

Liquid(Ø)Gas(Ø)

PipingConnections

mm(inch)

mm(inch)9.52(3/8)

19.05(3/4)

kW/V/Hz

kWBtu/h

Btu/h

Ø

40,000

46,000

1 / 220-240 / 50

11.7

13.5

Technical Specification

5

1135

1165

308

565

273

520

8012

4

900550

370

395

15

175

3

2

65

4

370

Note1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

1

1) Outdoor units

[Unit : mm]

1135

1165

308

565

273

520

8012

4

900550

370

395

15

175

65

370

[Unit : mm]

336

Product dataOutdoor units_Distributor type(1Ø)

Part 2 Product data

1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: U3

OUTDOOR UNIT

A8UW486FA3[FM48AH U33]A9UW566FA3[FM56AH U33]

Part Name

Air discharge grilleGas pipe connection

Liquid pipe connection

No.

2

3

1Remark

Technical Specification

Note

Supporter

Heating Capacity

Cooling Capacity

Power supplyModel Name

Liquid(Ø)Gas(Ø)

PipingConnections

mm(inch)

mm(inch)

kW

kWBtu/h

Btu/h

Ø/V/HzA8UW486FA3[FM48AH U33] A9UW566FA3[FM56AH U33]

1 / 220-240 / 5015.5

52,80016.4

56,0009.52(3/8)19.05(3/4)

1 / 220-240 / 5016.7

57,00017.9

61,0009.52(3/8)

19.05(3/4)

[Unit : mm] [Unit : mm]

336

Product dataOutdoor units_Distributor type(1Ø)

Part 2 Product data

1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

CHASSIS CODE: U3

OUTDOOR UNIT

A8UW486FA3[FM48AH U33]A9UW566FA3[FM56AH U33]

Part Name

Air discharge grilleGas pipe connection

Liquid pipe connection

No.

2

3

1Remark

Technical Specification

Note

Supporter

Heating Capacity

Cooling Capacity

Power supplyModel Name

Liquid(Ø)Gas(Ø)

PipingConnections

mm(inch)

mm(inch)

kW

kWBtu/h

Btu/h

Ø/V/HzA8UW486FA3[FM48AH U33] A9UW566FA3[FM56AH U33]

1 / 220-240 / 5015.5

52,80016.4

56,0009.52(3/8)

19.05(3/4)

1 / 220-240 / 5016.7

57,00017.9

61,0009.52(3/8)

19.05(3/4)

[Unit : mm] [Unit : mm]

Page 13: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

LG Air Conditioners 2010 58 _59

Page 14: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Plasma Filter

Allergy Free Filter

Triple Filter

Nano Carbon Filter

Multi split _ Wall mounted

Program by remote

Easy installation

Various indoor units

Note : * indicates color of panel *Mirror(R) *Silver(V) *Red(E) *Gold(G) *White Silver(H) *Blue(B) *Gallery(B)

Wall mounted MS07AH N40

CC07AW* NE3

MS09AH N40

CC09AW* NE3

MA09AH1 NF1

MS12AH N40

CC12AW* NE3

MA12AH1 NF1

2.1 2.6 3.5 5.3

MS18AH N50

CC18AW* N83

7

MS24AH N50

CC24AW* N83

Capacity (kW)

Mirror

Gallery

Hangingthe Indoor unit

Separate chassis bottom

Lift up using the supporter Piping Wiring Finishing

Easy wiringSupportDetachable

bottom

Optimised airflow

Stepping control

As you know, cool air falls and warm air rises. We’ve designed our units to target the airflow upwards when cooling and downwards when heating. It helps give your room a more complete coverage and means you’ll reach the perfect temperature that little bit faster.

Air purifying systemClean up the air you breathe with the touch of a button. Our unique air purifying system features six specialised filters, each designed to trap different kinds of airborne allergens and potentially harmful particles. No more airborne dust, no odours, no bacteria – just air that’s fresh, clean and better for your health.

• Pre filter• Plasma filter• Nano carbon filter• Triple filter• Allergy free filter• Nano bio fusion filter

Easy installationComfort operation

Cooling mode Heating mode

16º80º

Installation support clipWe’ve built the world’s first units to feature a support clip. It gives the installer easy access to the inside of the unit for fast installation.

Bigger piping spaceOur units have more space surrounding the piping inside the unit. It’s good news for installers and makes for faster installation time.

LG Co.A Co.B Co.C

67.7

72.0

116%

A(mm)

B(mm)

%

50.0

80.0

95%

60.0

70.0

100%

45.0

70.0

75%

ConventionalA

B

New

100% 145%

WorldFirst

User friendly designEasy to use

Left only Right only

*Only LIBERO

Page 15: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Specifications

Model Cooling capacity Btu/h kW Heating capacity Btu/h kW Current nominal Running current AAir flow rate cmm(H/M/L) cfmDimensions (WxHxD) Body mm(inch)Weight Body kg(lbs)Sound level (H/M/L) dB(A)+3Piping Liquid mm(inch)connections Gas mm(inch)Dehumidification rate l/h

MS07AH N40

7,0002.0580002.340.10

5.6/5.0/4.6198/177/163

840×270×153(33.1×10.6×6.0)

7(15.4) 29 / 25 / 20

6.35 (1/4)9.52 (3/8)

0.9

MS09AH N40

9,0002.64

10,0002.930.15

7.0/6.5/6.0247/230/212

840×270×153(33.1×10.6×6.0)

7(15.4) 33 / 29 / 22

6.35 (1/4)9.52 (3/8)

1.1

MS12AH N40

12,0003.52

13,2003.870.15

9.5/9.0/8.5336/318/300

840×270×153(33.1×10.6×6.0)

7(15.4) 36 / 32 / 29

6.35 (1/4)9.52 (3/8)

1.2

MS18AH N50

18,0005.28

19,8005.800.28

12.0/10.5/9.0424/371/318

1090×300×180(42.9×11.8×7.1)

13(28.7) 37 / 34 / 31

6.35 (1/4)12.7 (1/2)

2.3

MS24AH N50

23,0006.74

25,5007.470.28

14.0/13.0/11.0495/460/389

1090×300×180(42.9×11.8×7.1)

13(28.7) 41 / 39 / 34

6.35 (1/4)12.7 (1/2)

3.0

Note : Due to our policy of innovation some specifications may be changed without notification.Model Cooling capacity Btu/h kW Heating capacity Btu/h kW Running current AAir flow rate (H/M/L) cmm cfm Dimensions (WxHxD) Body mm(inch)Weight Body kg(lbs) Sound level (H/M/L) dB(A)±3 Piping connections Liquid mm(inch) Gas mm(inch) Dehumidification rate l/h

CC07AW* NE3

7,0002.05

8,0002.340.1

8.0/7.0/5.0282/247/177

915×282×165 (36.0×11.1×6.5)9.5(20.9)34/29/266.35 (1/4)9.52 (3/8)

1.0

CC09AW* NE3

9,0002.64

10,0002.930.15

10/8.0/6.0353/283/212

915×282×165 (36.0×11.1×6.5)9.5(20.9)35/30/276.35 (1/4)9.52 (3/8)

1.2

CC12AW* NE3

12,0003.52

13,2003.870.15

10/8.0/6.0353/283/212

915×282×165 (36.0×11.1×6.5)9.5(20.9)35/30/276.35 (1/4)9.52 (3/8)

1.5

CC18AW* N83

18,0005.28

19,8005.8

0.2812.6/11.5/10

445/406/3531107×299×200(43.6×11.8×7.9)

14.1(31.09)39/37/356.35 (1/4)12.7 (1/2)

2.0

CC24AW* N83

23,0006.74

25,5007.470.28

15/14/13530/494/459

1107×299×200(43.6×11.8×7.9)14.1(31.09)43/41/386.35 (1/4)12.7 (1/2)

2.5

Model Cooling capacity Btu/h kW Heating capacity Btu/h kW Running current AAir flow rate (H/M/L) cmm cfm Dimensions (WxHxD) Body mm(inch)Weight Body kg(lbs) Sound level (H/M/L) dB(A)±3 Piping connections Liquid mm(inch) Gas mm(inch) Dehumidification rate l/h

MA09AH1 NF1 MA12AH1 NF1

9,0002.64

10,0002.930.08

7.7/5.9/4.4272/208/155

600×600×146(23.6×23.6×5.7)15(33.1)

38 / 32 / 276.35(1/4)9.52(3/8)

1.2

12,0003.52

13,2003.870.08

8.9/7.3/5.6314/258/198

600×600×146(23.6×23.6×5.7)15(33.1)

44 / 38 / 326.35(1/4)9.52(3/8)

1.4

Note : Due to our policy of innovation some specifications may be changed without notification.

LG Air Conditioners 2010 12 _13

Page 16: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Multi split _ Ceiling cassette

Improved airflow

Independent vane control

A motor for each vane

We’ve increased the width of the vanes on our Cassette units for a more even airflow distribution. No more hot and cold patches in the corners of your room.

The vanes on our Cassette units can be controlled independently of each other. So whether you want to target airflow to a specific place in your room or would prefer a more balanced air circulation, the Cassette has a setting to suit.

Each of the four vanes on the Cassette has its own motor. It gives you complete control in air circulation and means that you don’t waste energy powering the whole unit when you’re only using one vane.

LG Cassette LG Cassette

27°C

15°C

t262524232221201918

Even air distribution

80mm wider!567mm

Conventional Conventional

27°C

15°C

t262524232221201918

Air flow dead zonein 4 corners

487mm

Direct air flow Indirect air flow

5 : 70º

3 : 50º

0 : 30º

1 : 20º

2 : 40º

Individual vane operation

Individual vane angle control

All vane operation

1 Vane, 1 Motor

Easy installationDetachable corner panels

One touch panel

Auto elevation grille (Accessory: PTEGM0)

Detachable corner panels make installation and servicing easy, resulting in minimal disruption to your business.

The simple ‘push up’ design makes life easy for installers, enabling them to connect the unit quickly.

The auto elevation grille can be fitted when your Cassette is installed. It allows the grille to be electronically lowered by up to 4.5m, making cleaning and servicing hassle-free.

* Please refer to the Product Data Book for available model

Detachable corner design

Refrigerant piping check’

Drain leakage check

Hanger adjustHanger adjust

Hanger adjust Drain leakage check

New Cassette

4.5m

Conventional3.5m

4-Point Support Structure Auto Horizontal Control Auto bottom detection

Comfort operation

Page 17: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Various indoor units

4-Way cassette

MT10AH NR0 MT12AH NR0

2.6 3.5 5.3

MT18AH NQ0

7

MT24AH NP0

Capacity (kW)

Specifications

LG Air Conditioners 2010 14 _15

9,0002.64

10,0002.930.35

8.5/7.5/6.5300/265/230

570×214×570(22.4×8.4×22.4) 700×30×700(27.5×1.2×27.5)

14(30.9)3(6.6)

32/29/256.35 (1/4) 9.52 (3/8)

1.1

Model Panel Cooling capacity Btu/h kW Heating capacity Btu/h kW Current nominal Running current A Air flow rate (H/M/L ) cmm cfm Dimensions (W*H*D) Body mm(inch) Decorative panel mm Weight Body kg(lbs) Decorative panel kg(lbs) Sound level (H/M/L) dB(A)±3 Piping connections Liquid inch(mm) Gas inch(mm) Dehumidification rate 1/h

12,0003.52

13,2003.870.35

9.5/8/6.5336/283/230

570×214×570(22.4×8.4×22.4) 700×30×700(27.5×1.2×27.5)

14(30.9)3(6.6)

35/31/276.35 (1/4) 9.52 (3/8)

1.2

18,0005.28

19,8005.80.43

13/12/10459/423/353

570×256×570(22.4×10.0×22.4) 700×30×700(27.5×1.2×27.5)

15(33.1)3(6.6)

40/37/346.35 (1/4) 12.7(1/2)

2.4

Ceiling cassette 4 way

Note : Due to our policy of innovation some specifications may be changed without notification.

MT24AH NP0PT-UMC

MT18AH NQ0PT-UQC

MT12AH NR0 PT-UQC

24,0007.03

26,4007.740.6

17/15/13600/530/459

840×204×840(33.1×8.0×33.1)950×25×950(37.4×1.0×37.4)

21(46.3)5(11.0)

39/37/346.35 (1/4) 12.7(1/2)

3.0

MT10AH NR0PT-UQC

Page 18: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Multi split_ Ceiling concealed duct

Linear ESP control

Precise temperature reading

A fan that’s quieter and easier to service

The capacity and operational volume of the unit are unaffected by changes in external static pressure. So you get quiet air conditioning and peak performance no matter what the static pressure is.

Phase control technology saves time and money for the installer.

Traditional air conditioning systems measure room temperature with a thermistor located on or inside the unit. But sometimes there can be a difference between the temperature measured at the point of airflow release and the actual room temperature. We’ve included a second thermistor in the wall-fixed remote that controls your system. Because it’s positioned away from your unit it will give a more accurate reading of room temperature. You can choose which thermistor you use to measure your room temperature with a switch on the remote control.

We’re always looking for ways to continue to bring our customers quieter air conditioning. A lightweight fan and specially designed fan housing minimises excess sound as the fan spins. The housing also makes for hassle-free servicing. It’s easy to dismantle and gives quick access to the fan. During servicing, the fan motor can be removed without disrupting the rest of the fan deck. So there’s minimal disruption to both your system, and your business.

*E.S.P is easily controlled by the remote controll

Ceiling concealed duct

LCD wired remote controller

Two thermistor control

Conventional fan LG fan and housing

Page 19: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Slim duct

High static duct

2.6

MB09AHL N12 MB12AHL N12 MB18AHL N22

MB18AH NH0

MB24AHL N22

MB24AH NH0

3.5 5.3 7.0Capacity (kW)

Ceiling concealed duct

Various indoor units

Specifications

Model Cooling capacity Btu/h kW Heating capacity Btu/h kW Current nominal Running current A Air flow rate (H/M/L) cmm cfm Dimensions (WxHxD) Body mm(inch) Weight Body kg(lbs) Sound level (H/M/L) dB(A)+3 Piping Liquid mm(inch) Connections Gas mm(inch) Dehumidification rate l/h

9,0002.64

10,0002.931.02

8.5/7.5/6.5300/265/230

820×190×575(32.3×7.5×22.6)20.5(45.2)31/26/256.35(1/4)9.52(3/8)

1.0

12,0003.52

13,2003.871.02

9.5/8.5/7.5336/300/265

820×190×575(32.3×7.5×22.6)20.5(45.2)33/31/266.35(1/4)9.52(3/8)

1.2

18,0005.27

19,8005.81.6

15/13.5/11.5530/477/406

1,100×190×575(43.3×7.5×22.6)26.5(58.4)34/31/296.35(1/4)12.7(1/2)

2.0

24,0007.03

26,4007.441.6

17/15/13.5600/530/477

1,100×190×575(43.3×7.5×22.6)27(59.5)

36/34/326.35(1/4)12.7(1/2)

2.5

Model Cooling capacity Btu/h kW Heating capacity Btu/h kW Current nominal Running current A Air flow rate (H/M/L) cmm cfm Dimensions (WxHxD) Body mm(inch) Weight Body kg(lbs) Sound level (H/M/L) dB(A)+3 Piping Liquid mm(inch) Connections Gas mm(inch) Dehumidification rate l/h

Ceiling concealed duct - high static duct

Note : Due to our policy of innovation some specifications may be changed without notification.

MB18AH NH0

24,0007.03

26,4007.740.75

18/16.5/14636/583/494

880×260×450(34.6×10.2×17.7)35(77.2)

38/36/346.35 (1/4)12.7(1/2)

2.5

18,0005.28

19,8005.80.75

16.5/14.5/13583/512/459

880×260×450(34.6×10.2×17.7)35(77.2)

36 / 34 / 326.35 (1/4)12.7(1/2)

2.0

Ceiling concealed duct - slim duct

MB24AH NH0

MB12AHL N12MB09AHL N12 MB18AHL N22 MB24AHL N22

LG Air Conditioners 2010 16 _17

Page 20: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Multi split _ Ceiling & floor

Flexible installationOur Ceiling & floor convertible units are among the most flexible in our range. The Indoor unit can be mounted at floor level or suspended from the ceiling. Either way you get great air conditioning coverage – right across your room. It’s the perfect option if you want more choice in where you position your unit.

Airflow direction controlHorizontal airflow controlSet the perfect horizontal airflow direction with manually adjustable louvers. Whether you want to direct airflow to a specific area, or would rather a more balanced coverage of your room – you can alter the airflow direction with ease.

Vertical airflow controlThe direction of the vertical airflow can be adjusted easily by remote control. So you can set the perfect airflow with the touch of a button.

Vertical

Horizontal

2.6

MV09AH NE0 MV12AH NE0 MV18AH NB0 MV24AH NB0

3.5 5.3 7.0Capacity (kW)

Various Indoor Units

Specifications

Model Cooling Capacity Btu/h kW Heating Capacity Btu/h kW Current Nominal running current A Air flow rate (H/M/L) cmm cfm Demensions (W*H*D) Body mm(inch) Weight Body kg(Ibs) Sound level (H/M/L) dB(A)±3 Piping Connections Liquid mm(inch) Gas mm(inch) Dehumidification rate 1/h

9,0002.64

10,0002.930.56

7.8/6.4/5.0276/226/177

900×200×490(35.4×7.9×19.3)12(26.5)

36/32/286.35 (1/4)9.52(3/8)

1.0

12,0003.52

13,2003.870.56

10.0/8.3/6.5353/293/230

900×200×490(35.4×7.9×19.3)12(26.5)

40/36/316.35 (1/4)9.52(3/8)

1.2

18,0005.27

19,8005.80.67

13.5/12/11477/424/388

1,200×205×615(47.2×8.1×24.2)30(66.1)

43 / 40 / 376.35 (1/4)12.7(1/2)

2.0

MV09AH NE0 MV12AH NE0 MV18AH NB0 MV24AH NB0

24,0007.03

25,2007.380.67

15/13.5/12530/477/424

1,200×205×615(47.2×8.1×24.2)30(66.1)

45 / 42 / 396.35 (1/4)12.7(1/2)

3.0

Note : Due to our policy of innovation some specifications may be changed without notification.

Ceiling & Floor

Page 21: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Multi split _ ConsoleLG Air Conditioners 2010 18 _19

2.6

CQ09 NA0 CQ18 NA0CQ12 NA0

3.5 5.3Capacity (kW)

Various Indoor Units

Specifications

Model Cooling Capacity Btu/h kW Heating Capacity Btu/h kW Running current A Air flow rate (H/M/L/Sleep) cmm cfm Demensions (W*H*D) Body mm(inch) Weight Body kg(Ibs) Sound level (H/M/L/Sleep) dB(A)±3 Piping Connections Liquid mm(inch) Gas mm(inch) Dehumidification rate 1/h

9,0002.64

10,0002.930.56

8.1/6.5/5.2286/230/184

700×600×210(27.5×23.6×8.3)13.8(30.4)38/32/276.35 (1/4)9.52(3/8)

1.0

12,0003.52

13,2003.870.56

8.1/6.5/5.2286/230/184

700×600×210(27.5×23.6×8.3)13.8(30.4)39/32/276.35 (1/4)9.52(3/8)

1.2

18,0005.27

19,8005.8

0.5610.1/8.6/7.2

357/304/254700×600×210(27.5×23.6×8.3)

13.8(30.4)44/39/356.35 (1/4)12.7(1/2)

2.0

Note : Due to our policy of innovation some specifications may be changed without notification.

Healthy Air (3 stage air filter system)

Comfort Air Flow•Different air flow of cooling & heatingFor cooling, the vane is adjusted upwards to let the cold air travel up. As for heating, the vane sends theheated air downwards to balance room temperature specially for floor.

•Quick floor heatingConsole air conditioners can operate faster to provider more powerful performance. The results is toattain the desired temperature much faster in floor heating mode than conventional air conditioners.

• EZ vane tap control •Quiet operation (22dB)

1st Advanced pre filter :The antibacterial pre-filter primarily reduces large dust, mould and quilt dust.

2nd Allergy Filter :Filter consists of enzyme that breaks down allergen, apatite, and organic/inorganic binder that attaches the enzyme to the filter. When the air passes the filter, allergen clings to the filter and like tiny pairs of scissors the enzymes cut allergen's protein to deactivate the allergen.

3rd Nano Plazma Inon Generator :The sterilized ion generating system, Ion Generator, emits around 1.2 million ions, and catches hazardous substances floating in the air, therefore proactively looking for and catching germs.

Cooling Heating (Nomal) Heating (Floor Heating Mode)

Company A

12 minutes 30 seconds

9 minutes 40 seconds

50 minutes 9 minutes 30 seconds

8 minutes 40 seconds

Company B Electric Heater LG

(Test Condition :Target Temp 23°C, Indoor Room:13°C~ , Outdoor Room:7°C)

27°C

15°C

t262524232221201918

Vertical

Lead Time for Heating

(13°C 21°C)

Horizontal

LGFloor Heating Mode

55dBoffice

50dBconversation

40dBlibrary

22dBLG

20dBempty studio

Console

CQ12 NA0 CQ18 NA0CQ09 NA0

Page 22: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Accessory_

Distributor box

Smoother installation

PMBD3620, PMBD3630, PMBD3640, PMBD7220, PMBD7230

Features• Distribution of refrigerant to Indoor units

• Suitable for 2, 3, or 4 Indoor units

• Helps control PCB and control panel of units

• Contains Electronic Expansion Valve (EEV) for more precise metering

• Internally insulated (prevents the need for drainage)

• Flare joints for easy installation

• Compact design

2 Indoors 3 Indoors 4 IndoorsFor

Distributor

Various distributors can make much easier installation for any sites

Model Connectable Number of Indoor units Indoor units Capacity Btu/h Power Source ø/V/Hz Power Consumption W Running current A Dimensions W*H*D mm(inch) Net weight kg/Ib Piping Connection Liquid(ø) mm(inch) (To Outdoor Unit) Gas(ø) mm(inch) Piping Connection Liquid(ø) mm(inch) (To Indoor unit) Gas(ø) mm(inch) Accessories Hanger (Bracket) EA Screw EA Manual EA

PMBD3620

1~27k/9k/12k/18k/24k

1, 50, 220~24010

0.05302×143×252(11.9×5.6×9.9)

4.8/10.69.52(3/8)19.05(3/4)

6.35(1/4)×2EA9.52(3/8)×2EA

481

PMBD3630

1~37k/9k/12k/18k/24k

1, 50, 220~24010

0.05302×143×252(11.9×5.6×9.9)

4.9/10.89.52(3/8)19.05(3/4)

6.35(1/4)×3EA9.52(3/8)×3EA

481

PMBD3640

1~47k/9k/12k/18k/24k

1, 50, 220~24010

0.05302×143×252(11.9×5.6×9.9)

4.8/10.69.52(3/8)19.05(3/4)

6.35(1/4)×4EA9.52(3/8)×4EA

481

PMBD7220

1~218k/24k/30k/36k1, 50, 220~240

100.05

302×143×252(11.9×5.6×9.9)4.8/10.69.52(3/8)19.05(3/4)

6.35(1/4)×2EA12.7(1/2)×2EA

481

PMBD7230

1~318k/24k/30k/36k1, 50, 220~240

100.05

302×143×252(11.9×5.6×9.9)4.9/10.8

9.52(3/8)19.05(3/4)

6.35(1/4)×3EA12.7(1/2)×3EA

481

Note: 1. The piping connection must suit the piping size of the Indoor unit(s). If required, use the connector included with the Indoor unit.2. The Distributor Box should be installed inside the building.

Note : Due to our policy of innovation some specifications may be changed without notification.

No brazing Just flaring

Specifications

PMBD3640PMBD3630PMBD7230

PMBD3620PMBD7220

Page 23: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Y Branch and Branch KitPMBL3620 / PMBL5620 (2units) / PMBL1203F0 (3units)

Features• Y Branch and Branch Kit makes multi installation much easier

• Suitable for both gas and liquid operation

• Insulation for the branches is provided

Distributor Box

Y Branch

Application

Accessory model name

Model name No. of BD units Applicable modelSpecification

LiquidGas

PMBL3620

PMBL5620

PMBL1203F0

2 units

2 units

3 units

Only 3ø, 36k Btu/h

1ø, 3ø

1ø, 3ø

Ø15.88 Ø15.88

Ø15.88

Ø6.35 Ø6.35

Ø6.35

Ø19.05 Ø19.05

Ø19.05

Ø9.52 Ø9.52

Ø9.52

Ø15.88 Ø15.88

Ø15.88

Ø6.35 Ø6.35

Ø6.35

Ø19.05 Ø19.05

Ø19.05

Ø9.52 Ø9.52

Ø9.52

Ø15.88 Ø15.88

Ø15.88

Ø6.35 Ø6.35

Ø6.35

Ø19.05 Ø19.05

Ø19.05

Ø9.52 Ø9.52

Ø9.52

Ø15.88 Ø15.88

Ø15.88

Ø6.35 Ø6.35

Ø6.35

Ø19.05 Ø19.05

Ø19.05

Ø9.52 Ø9.52

Ø9.52

(Unit : mm)

LG Air Conditioners 2010 20 _21

Page 24: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

1 Unit

2 Unit

3 Unit

MU3M19 UE0

UNIT-A

5

7

9

12

18

5

5

5

5

5

7

7

9

7

9

12

7

9

12

5

5

5

5

5

5

5

5

5

5

7

7

7

7

9

7

9

UNIT-B

5

7

9

12

18

7

9

9

12

12

12

18

18

18

5

5

5

5

7

7

7

9

9

12

7

7

9

7

9

9

9

Total

5

7

9

12

18

10

12

14

17

23

14

16

18

19

21

24

25

27

30

15

17

19

22

19

21

24

23

26

29

21

23

25

26

27

28

30

UNIT-C

5

7

9

12

7

9

12

9

12

12

7

9

9

12

9

12

12

UNIT-A(Btu/h)

5000

7000

9000

12000

18000

5000

5000

5000

5000

3913

7000

7000

9000

6632

7714

9000

9000

9000

9000

5000

5000

4737

4091

4737

4286

3750

3913

3462

3103

6000

5478

5040

4846

6000

4500

5400

UNIT-B(Btu/h)

-

-

-

-

5000

7000

9000

12000

14087

7000

9000

9000

11368

10286

9000

9000

9000

9000

5000

5000

4737

4091

6632

6000

5250

7043

6231

7448

6000

5478

6480

4846

6000

5786

5400

UNIT-C(Btu/h)

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

5000

7000

8526

9818

6632

7714

9000

7043

8308

7448

6000

7043

6480

8308

6000

7714

7200

Btu/h

4,600

4,600

5,400

7,200

10,800

6,000

7,200

8,400

10,200

10,800

8,400

9,600

10,800

10,800

10,800

10,800

10,800

10,800

10,800

9,000

10,200

10,800

10,800

10,800

10,800

10,800

10,800

10,800

10,800

10,800

10,800

10,800

10,800

10,800

10,800

10,800

kW

1.3

1.2

1.6

2.1

3.2

1.8

2.1

2.5

3.0

3.2

2.5

2.8

3.2

3.2

3.2

3.2

3.2

3.2

3.2

2.6

3.0

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

Btu/h

5,000

7,000

9,000

12,000

18,000

10,000

12,000

14,000

17,000

18,000

14,000

16,000

18,000

18,000

18,000

18,000

18,000

18,000

18,000

15,000

17,000

18,000

18,000

18,000

18,000

18,000

18,000

18,000

18,000

18,000

18,000

18,000

18,000

18,000

18,000

18,000

kW

1.5

2.1

2.6

3.5

5.3

2.9

3.5

4.1

5.0

5.3

4.1

4.7

5.3

5.3

5.3

5.3

5.3

5.3

5.3

4.4

5.0

5.3

5.3

5.3

5.3

5.3

5.3

5.3

5.3

5.3

5.3

5.3

5.3

5.3

5.3

5.3

Btu/h

6,000

8,400

10,800

14,400

21,600

12,000

14,400

16,800

20,400

21,600

16,800

19,200

21,600

21,600

21,600

21,600

21,600

21,600

21,600

18,000

20,400

21,600

21,600

21,600

21,600

21,600

21,600

21,600

21,600

21,600

21,600

21,600

21,600

21,600

21,600

21,600

kW

1.8

2.5

3.2

4.2

6.3

3.5

4.2

4.9

6.0

6.3

4.9

5.6

6.3

6.3

6.3

6.3

6.3

6.3

6.3

5.3

6.0

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

Min

480

480

541

690

924

811

811

811

811

811

811

906

924

924

924

924

924

924

924

947

947

947

947

947

947

947

947

947

947

947

947

947

947

947

947

947

Rating

480

560

760

1150

1330

811

910

1020

1230

1250

1020

1170

1250

1250

1250

1250

1250

1250

1250

1050

1140

1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

Max

960

1160

1580

1980

2370

1690

1830

2170

2250

2370

2090

2210

2370

2370

2370

2370

2370

2370

2290

2350

2320

2350

2350

2350

2350

2350

2350

2350

2350

2350

2350

2350

2350

2350

2350

2350

Min Rating

Operation Each Capacity

Cooling

Input(W)Total CapacityCombination

Note : 1. Cooling Capacity is based on : indoor temp.27°CDB, 19°CWB ; outdoor temp. 35°CDB2. Heating Capacity is based on : indoor temp.20°CDB ; outdoor temp. 7°CDB, 6°CWB3. The total ability of connected a indoor unit is up to 30kBtu/h4. At least two indoor units should be connected.

Combination Table_

Page 25: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

1 Unit

2 Unit

3 Unit

MU3M19 UE0

UNIT-A

5

7

9

12

18

5

5

5

5

5

7

7

9

7

9

12

7

9

12

5

5

5

5

5

5

5

5

5

5

7

7

7

7

9

7

9

UNIT-B

5

7

9

12

18

7

9

9

12

12

12

18

18

18

5

5

5

5

7

7

7

9

9

12

7

7

9

7

9

9

9

Total

5

7

9

12

18

10

12

14

17

23

14

16

18

19

21

24

25

27

30

15

17

19

22

19

21

24

23

26

29

21

23

25

26

27

28

30

UNIT-C

5

7

9

12

7

9

12

9

12

12

7

9

9

12

9

12

12

UNIT-A(Btu/h)

5500

8400

10800

13200

21600

5500

5500

5500

5500

4696

8400

8400

10800

7957

9257

10800

10800

10800

10800

5500

5500

5684

4909

5684

5143

4500

4696

4154

3724

7200

6574

6048

5815

7200

5400

6480

UNIT-B(Btu/h)

-

-

-

-

5500

8400

10800

13200

16904

8400

10800

10800

13643

12343

10800

10800

10800

10800

5500

5500

5684

4909

7958

7200

6300

8452

7477

8938

7200

6574

7776

5815

7200

6943

6480

UNIT-C(Btu/h)

-

-

-

-

5500

8400

10232

11782

7958

9257

10800

8452

9969

8938

7200

8452

7776

9969

7200

9257

8640

Btu/h

4800

4800

6480

7920

12960

6600

8340

9780

11220

12960

10080

11520

12960

12960

12960

12960

12960

12960

12960

9900

11640

12960

12960

12960

12960

12960

12960

12960

12960

12960

12960

12960

12960

12960

12960

12960

kW

1.4

1.4

1.9

2.3

3.8

1.9

2.4

2.9

3.3

3.8

3.0

3.4

3.8

3.8

3.8

3.8

3.8

3.8

3.8

2.9

3.4

3.8

3.8

3.8

3.8

3.8

3.8

3.8

3.8

3.8

3.8

3.8

3.8

3.8

3.8

3.8

Btu/h

5500

8400

10800

13200

21600

11000

13900

16300

18700

21600

16800

19200

21600

21600

21600

21600

21600

21600

21600

16500

19400

21600

21600

21600

21600

21600

21600

21600

21600

21600

21600

21600

21600

21600

21600

21600

kW

1.6

2.5

3.2

3.9

6.3

3.2

4.1

4.8

5.5

6.3

4.9

5.6

6.3

6.3

6.3

6.3

6.3

6.3

6.3

4.8

5.7

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

Btu/h

6,325

9660

12420

15180

24840

12650

15985

18745

21505

24840

19320

22080

24840

24840

24840

24840

24840

24840

24840

18975

22310

24840

24840

24840

24840

24840

24840

24840

24840

24840

24840

24840

24840

24840

24840

24840

kW

1.9

2.8

3.6

4.4

7.3

3.7

4.7

5.5

6.3

7.3

5.7

6.5

7.3

7.3

7.3

7.3

7.3

7.3

7.3

5.6

6.5

7.3

7.3

7.3

7.3

7.3

7.3

7.3

7.3

7.3

7.3

7.3

7.3

7.3

7.3

7.3

Min

586

586

771

866

1150

933

933

933

1095

1095

933

1001

1150

1150

1150

1150

1150

1150

1150

1095

1095

1095

1095

1095

1095

1095

1095

1095

1095

1095

1095

1095

1095

1095

1095

1095

Rating

860

980

1140

1370

1640

1080

1280

1460

1500

1530

1460

1530

1580

1580

1580

1580

1490

1490

1490

1270

1310

1330

1330

1330

1330

1330

1330

1330

1330

1330

1330

1330

1330

1330

1330

1330

Max

1290

1400

1540

1820

2480

1640

1720

1890

2040

2480

2280

2410

2480

2480

2480

2480

2480

2480

2480

2260

2380

2400

2400

2400

2400

2400

2400

2400

2400

2400

2400

2400

2400

2400

2400

2400

Min MaxRating

Operation Each Capacity

Heating

Input(W)Total CapacityCombination

Note : 1. Cooling Capacity is based on : indoor temp.27°CDB, 19°CWB ; outdoor temp. 35°CDB2. Heating Capacity is based on : indoor temp.20°CDB ; outdoor temp. 7°CDB, 6°CWB3. The total ability of connected a indoor unit is up to 30kBtu/h4. At least two indoor units should be connected.

LG Air Conditioners 2010 22_23

Page 26: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Combination Table_

Note : 1. Cooling Capacity is based on : indoor temp.27°CDB, 19°CWB ; outdoor temp. 35°CDB2. Heating Capacity is based on : indoor temp.20°CDB ; outdoor temp. 7°CDB, 6°CWB3. The total ability of connected a indoor unit is up to 39kBtu/h4. At least two indoor units should be connected.

1 Unit

2 Unit

3Unit

4Unit

MU4M25 UE0

UNIT-A57912182455577597951279512791812555557575575797555975797555129757955555555575575575557575575955775597

UNIT-B

57979129121218121818241824241824555777579799799512791297129512712912971255555755775775779577595977957975797

Total579121824101214141617181921232425272930313336361517191921212223232425262627282829303031323233343435363636373838392022242426262728282829303031313232333333343435353536363737373839393939

UNIT-C

5797971299129121291218121812121818121824182412181824241855577759777979799597129799129979125997

UNIT-D

5797971299712991212991812121291812121291818121224181218

UNIT-A(Btu/h)5,000 7,000 9,000 12,000 18,000 24,000 5,000 5,000 5,000 7,000 7,000 5,000 9,000 7,000 9,000 5,000 11,500 6,720 8,000 4,138 9,600 5,419 6,545 12,000 8,000 5,000 5,000 5,000 5,000 5,000 7,000 5,000 7,000 5,000 5,000 6,720 4,615 6,462 8,000 6,000 4,286 4,138 4,000 7,200 5,419 3,750 5,250 6,545 4,941 3,529 3,429 3,333 8,000 6,000 4,541 3,158 4,421 5,538 5,000 5,000 5,000 5,000 4,615 4,615 4,444 4,286 4,286 6,000 4,138 4,000 5,600 3,871 3,871 5,250 3,750 3,636 3,636 5,091 3,529 4,941 3,429 3,429 4,800 3,333 6,000 3,243 3,243 4,541 4,421 3,077 3,077 5,538 4,308

UNIT-B(Btu/h)------

5,000 7,000 9,000 7,000 9,000 12,000 9,000 12,000 12,000 18,000 11,500 17,280 16,000 19,862 14,400 18,581 17,455 12,000 16,000 5,000 5,000 5,000 7,000 7,000 7,000 5,000 7,000 9,000 7,000 8,640 8,308 6,462 8,000 7,714

4,286 9,931 5,600 7,200 9,290 6,750 5,250 8,727 6,353 3,529 8,229 4,667 8,000 6,000 7,784 5,684 4,421 7,385 5,000 5,000 5,000 5,000 4,615 6,462 4,444 4,286 6,000 6,000 4,138 5,600 5,600 3,871 5,419 5,250 6,750 3,636 5,091 5,091 3,529 6,353 3,429 6,171

4,800 4,667 6,000 3,243 4,541 5,838 4,421 3,077 4,308 5,538 4,308

UNIT-C(Btu/h)-------------------------

5,000 7,000 9,000 7,000 9,000 7,000 12,000 9,000 9,000 12,000 8,640 11,077 11,077 8,000 10,286 15,429 9,931

14,400 9,600 9,290 13,500 13,500 8,727 12,706 16,941 12,343 16,000 8,000 12,000 11,676 15,158 15,158 11,077 5,000 5,000 5,000 7,000 6,462 6,462 4,444 7,714

6,000 6,000 5,793 7,200 5,600 6,968 5,419 6,750 6,750 3,636 6,545 5,091 8,471 6,353 4,800 6,171 6,171

8,000 6,000 5,838 4,541 5,838 7,579 3,077 5,538 5,538 4,308

UNIT-D(Btu/h)----------------------------------------------------------

5,000 7,000 9,000 7,000 8,308 6,462 10,667 7,714 7,714

6,000 9,931 7,200 7,200 9,290 9,290 6,750 6,750 13,091 8,727 8,727 8,471 6,353 12,343 8,229 8,229 8,000 6,000 11,676 11,676 7,784 7,579 14,769 11,077 7,385 11,077

kW1.3 1.9 1.9 2.1 3.2 4.2 1.8 2.1 2.5 2.5 2.8 3.0 3.2 3.4 3.7 4.1 4.1 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 2.6 3.0 3.4 3.4 3.7 3.7 3.9 4.1 4.1 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 3.5 3.9 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2

Btu/h6,300 6,300 6,300 7,200

10,800 14,400 6,000 7,200 8,400 8,400 9,600 10,200 10,800 11,400 12,600 13,800 13,800 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 9,000 10,200 11,400 11,400 12,600 12,600 13,200 13,800 13,800 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 12,000 13,200 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400 14,400

Btu/h5,000 7,000 9,000 12,000 18,000 24,000 10,000 12,000 14,000 14,000 16,000 17,000 18,000 19,000 21,000 23,000 23,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 15,000 17,000 19,000 19,000 21,000 21,000 22,000 23,000 23,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 20,000 22,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000

kW1.52.12.63.55.37.12.93.54.14.14.75.05.35.66.26.86.87.17.17.17.17.17.17.17.14.45.05.65.66.26.26.56.86.87.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.15.96.57.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.17.1

Btu/h5,500 7,700 9,900 13,200 19,800 25,500 11,000 13,200 15,400 15,400 17,600 18,700 19,800 20,900 23,100 23,100 25,500 26,500 27,500 27,500 28,800 29,000 29,000 29,000 29,000 18,000 20,400 22,800 22,800 25,200 25,200 26,400 27,600 27,600 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 24,000 26,400 28,500 28,500 28,500 28,500 28,500 28,500 28,500 28,500 28,500 29,000 29,000 28,500 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000

kW1.62.32.93.95.87.53.23.94.54.55.25.55.86.16.86.87.57.88.18.18.58.58.58.58.55.36.06.76.77.47.47.88.18.18.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.57.17.88.48.48.48.48.48.48.48.48.48.58.58.48.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.5

Min720 720 720 672

1,002 1,230 756 756 876 756 876

1,008 1,002 1,008 1,044 1,284 1,194 1,284 1,284 1,284 1,284 1,284 1,284 1,284 1,284 1,044 1,044 1,152 1,044 1,152 1,044 1,200 1,152 1,152 1,200 1,200 1,200 1,200 1,200 1,200 1,230 1,200 1,230 1,200 1,200 1,230 1,230 1,230 1,230 1,230 1,230 1,230 1,230 1,230 1,230 1,230 1,230 1,230 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194 1,194

Rated720 720 850 1,120 1,670 2,010 910

1,020 1,100 1,100 1,220 1,350 1,510 1,640 1,700 1,770 1,910 1,830 1,830 1,830 1,830 1,830 1,830 1,830 1,830 1,050 1,260 1,450 1,450 1,540 1,540 1,610 1,790 1,790 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,820 1,470 1,590 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770 1,770

Max810 810

1,030 1,510 2,150 3,090 1,680 1,860 2,020 2,020 2,170 2,260 2,560 2,710 2,830 2,870 3,090 2,980 2,980 2,980 2,980 2,980 2,980 2,980 2,980 2,100 2,410 2,730 2,730 2,820 2,820 2,850 2,910 2,910 3,050 3,050 3,050 3,050 3,050 3,050 3,050 3,050 3,020 3,050 3,050 3,020 3,020 3,050 3,020 3,020 3,020 3,020 3,050 3,020 3,020 3,020 3,020 3,020 2,700 2,830 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010 3,010

Min MaxRating

Operation Each Capacity

Cooling

Input (W)Total CapacityCombination of Indoor Unit (kBtu/h)

Page 27: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

LG Air Conditioners 2010 24_25

Note : 1. Cooling Capacity is based on : indoor temp.27°CDB, 19°CWB ; outdoor temp. 35°CDB2. Heating Capacity is based on : indoor temp.20°CDB ; outdoor temp. 7°CDB, 6°CWB3. The total ability of connected a indoor unit is up to 39kBtu/h4. At least two indoor units should be connected.

1 Unit

2 Unit

3Unit

4Unit

MU4M25 UE0

UNIT-A57912182455577597951279512791812555557575575797555975797555129757955555555575575575557575575955775597

UNIT-B

57979129121218121818241824241824555777579799799512791297129512712912971255555755775775779577595977957975797

Total579121824101214141617181921232425272930313336361517191921212223232425262627282829303031323233343435363636373838392022242426262728282829303031313232333333343435353536363737373839393939

UNIT-C

5797971299129121291218121812121818121824182412181824241855577759777979799597129799129979125997

UNIT-D

5797971299712991212991812121291812121291818121224181218

UNIT-A(Btu/h)

8,000 10,000 13,200 19,800 25,400 5,500 5,500 5,500 8,400 8,400 5,500 10,800 8,400 10,800 5,500 13,200 7,784 9,600 4,966 11,520 6,503 7,855 14,400 9,600 5,500 5,500 5,500 5,500 5,500 8,400 5,500 8,400 5,500 6,000 8,064 5,538 7,754 9,600 7,200 5,143 4,966 4,800 8,640 6,503 4,500 6,300 7,855 5,929 4,235 4,114

4,000 9,600 7,200 5,449 3,789 5,305 6,646 5,500 5,500 5,500 5,500 5,538 5,538 5,333 5,143 5,143 7,200 4,966 4,800 6,720 4,645 4,645 6,300 4,500 4,364 4,364 6,109 4,235 5,929 4,114 4,114 5,760 4,000 7,200 3,892 3,892 5,449 5,305 3,692 3,692 6,646 5,169

UNIT-B(Btu/h)

-----

5,500 8,400 10,000 8,400 10,800 13,200 10,800 14,400 14,400 19,800 13,200 20,016 19,200 23,834 17,280 22,297 20,945 14,400 19,200 5,500 5,500 5,500 8,400 8,400 8,400 5,500 8,400 10,000 8,400 10,368 9,969 7,754 9,600 9,257 5,143 11,917 6,720 8,640 11,148 8,100 6,300 10,473 7,624 4,235 9,874 5,600 9,600 7,200 9,341 6,821 5,305 8,862 5,500 5,500 5,500 5,500 5,538 7,754 5,333 5,143 7,200 7,200 4,966 6,720 6,720 4,645 6,503 6,300 8,100 4,364 6,109 6,109 4,235 7,624 4,114 7,406 5,760 5,600 7,200 3,892 5,449 7,005 5,305 3,692 5,169 6,646 5,169

UNIT-C(Btu/h)

------------------------

5,500 8,400 10,000 8,000 10,000 8,400 13,200 10,800 10,000 14,400 10,368 13,292 13,292 9,600 12,343 18,514 11,917 17,280 11,520 11,148

16,200 16,200 10,473 15,247 20,329 14,811

19,200 9,600 14,400 14,011 18,189 18,189 13,292 5,500 5,500 5,500 7,700 7,754 7,754 5,333 9,257 7,200 7,200 6,952 8,640 6,720 8,361 6,503 8,100 8,100 4,364 7,855 6,109 10,165 7,624 5,760 7,406 7,406 9,600 7,200 7,005 5,449 7,005 9,095 3,692 6,646 6,646 5,169

UNIT-D(Btu/h)

------------------------

5,500 8,000 9,900 7,700 9,969 7,754

12,800 9,257 9,257 7,200 11,917 8,640 8,640 11,148 11,148 8,100 8,100 15,709 10,473 10,473 10,165 7,624 14,811 9,874 9,874 9,600 7,200 14,011 14,011 9,341 9,095 17,723 13,292 8,862 13,292

kW1.5 2.2 2.2 2.3 3.5 4.5 1.9 2.5 2.7 3.0 3.4 3.3 3.8 4.0 4.4 4.5 4.7 4.9 5.1 5.1 5.1 5.1 5.1 5.1 5.1 2.9 3.4 3.7 3.9 4.2 4.4 4.3 4.9 4.5 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 3.9 4.3 4.7 4.7 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1

Btu/h7,560 7,560 7,560 7,920 11,880 15,240 6,600 8,340 9,300 10,080 11,520 11,220 12,960 13,680 15,120 15,180 15,840 16,680 17,280 17,280 17,280 17,280 17,280 17,280 17,280 9,900 11,640 12,600 13,140 14,340 15,120 14,520 16,560 15,300 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 13,200 14,700 15,840 15,840 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280 17,280

Btu/h5,500 8,000 10,000 13,200 19,800 25,400 11,000 13,900 15,500 16,800 19,200 18,700 21,600 22,800 25,200 25,300 26,400 27,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 16,500 19,400 21,000 21,900 23,900 25,200 24,200 27,600 25,500 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 22,000 24,500 26,400 26,400 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800

kW1.62.42.93.95.87.53.24.14.64.95.65.56.46.77.47.47.88.28.58.58.58.58.58.58.54.95.76.26.47.07.47.18.17.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.56.57.27.87.88.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.58.5

Btu/h6,050 8,800 10,900 14,500 21,800 26,600 12,100 15,290 18,500 18,500 21,100 23,700 23,700 25,000 27,700 27,830 29,040 30,000 31,500 32,000 32,000 32,000 32,000 32,000 32,000 18,150 21,340 23,100 24,090 26,290 27,700 26,620 30,000 28,050 31,500 30,000 31,500 31,500 31,500 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 24,200 26,950 29,040 29,040 31,500 31,500 31,500 31,500 31,500 31,500 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000

kW1.82.63.24.36.47.83.64.55.45.46.27.07.07.48.18.28.58.89.39.49.49.49.49.49.45.36.36.87.17.78.17.88.88.29.38.89.39.39.39.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.47.17.98.58.59.39.39.39.39.39.39.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.49.4

Min880 880 880 880 1,200 1,368 918 918

1,038 918

1,038 1,212 1,200 1,212 1,260 1,428 1,368 1,428 1,428 1,428 1,428 1,428 1,428 1,428 1,428 1,260 1,260 1,278 1,260 1,278 1,260 1,308 1,278 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,308 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176 1,176

Rated840 880 1,010 1,370 2,080 2,770 970 1,160 1,400 1,400 1,710 1,890 2,060 2,160 2,390 2,630 2,770 2,660 2,660 2,660 2,660 2,660 2,660 2,660 2,660 1,260 1,530 1,750 1,750 1,860 1,860 1,950 2,020 2,020 2,110 2,110 2,110 2,110 2,110 2,110

2,080 2,110

2,080 2,110 2,110

2,080 2,080 2,110

2,080 2,080 2,080 2,080 2,110

2,080 2,080 2,080 2,080 2,080 1,650 1,760 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850 1,850

Max1,050 1,200 1,360 1,900 2,730 3,100 1,300 1,850 2,200 2,200 2,510 2,700 2,660 2,790 3,010 3,050 3,100 3,050 3,050 3,050 3,050 3,050 3,050 3,050 3,050 2,430 2,540 2,680 2,680 2,810 2,810 2,860 2,980 2,980 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 3,090 2,710 2,890 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060 3,060

Min MaxRating

Operation Each Capacity

Heating

Input (W)Total CapacityCombination of Indoor Unit (kBtu/h)

Page 28: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Combination Table_

Note : 1. Cooling Capacity is based on : indoor temp.27°CDB, 19°CWB ; outdoor temp. 35°CDB2. Heating Capacity is based on : indoor temp.20°CDB ; outdoor temp. 7°CDB, 6°CWB3. The total ability of connected a indoor unit is up to 48kBtu/h4. At least two indoor units should be connected.

1 Unit

2 Unit

3Unit

4Unit

MU5M30 U40

UNIT-A579121824555775979512795127918121824555557575575797555975797555129757975512977995121255555555575575

UNIT-B

5797912912121812181824182424182424245557775797997995127912971295127129129712912181291812181218181255555755775775

UNIT-C

5797971299129121291218121812121818121824182412181824241824241818241824182424182455577759777979

UNIT-D

57979712997129912

UNIT-E Total5791218241012141416171819212324252729303133363642481517191921212223232425262627282829303031323233343435363636373838394041414242434345454748482022242426262728282829303031

UNIT-A(Btu/h)5,000 7,000 9,000 12,000 18,000 24,000 5,000 5,000 5,000 7,000 7,000 5,000 9,000 7,000 9,000 5,000 12,000 7,000 9,000 5,000 12,000 6,774 8,182

15,000 10,000 12,857 15,000 5,000 5,000 5,000 5,000 5,000 7,000 5,000 7,000 5,000 5,000 7,000 5,000 7,000 9,000 7,000 5,000 5,000 5,000 9,000 6,774 4,688 6,563 8,182 6,176 4,412 4,286 4,167

10,000 7,500 5,676 3,947 5,526 6,923 5,250 3,659 3,659 8,571 6,429 4,884 4,884 6,000 6,000 3,191 7,500 7,500 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 7,000 5,000 5,000 7,000 4,839

UNIT-B(Btu/h)------

5,000 7,000 9,000 7,000 9,000 12,000 9,000 12,000 12,000 18,000 12,000 18,000 18,000 24,000 18,000 23,226 21,818 15,000 20,000 17,143

15,000 5,000 5,000 5,000 7,000 7,000 7,000 5,000 7,000 9,000 7,000 9,000 9,000 7,000 9,000 9,000 5,000 12,000 7,000 9,000 11,613 8,438 6,563 10,909 7,941 4,412

10,286 5,833 10,000 7,500 9,730 7,105 5,526 9,231 6,750 8,780 13,171 8,571 6,429 12,558 8,372

12,000 8,000 11,489 11,250 7,500 5,000 5,000 5,000 5,000 5,000 7,000 5,000 5,000 7,000 7,000 5,000 7,000 7,000 4,839

UNIT-C(Btu/h)---------------------------

5,000 7,000 9,000 7,000 9,000 7,000 12,000 9,000 9,000 12,000 9,000 12,000 12,000 9,000 12,000 18,000 12,000 18,000 12,000 11,613 16,875 16,875 10,909 15,882 21,176 15,429 20,000 10,000 15,000 14,595 18,947 18,947 13,846 18,000 17,561 13,171

12,857 17,143 12,558 16,744 12,000 16,000 15,319 11,250 15,000 5,000 5,000 5,000 7,000 7,000 7,000 5,000 9,000 7,000 7,000 7,000 9,000 7,000 8,710

UNIT-D(Btu/h)------------------------------------------------------------------------

5,000 7,000 9,000 7,000 9,000 7,000 12,000 9,000 9,000 7,000 12,000 9,000 9,000 11,613

UNIT-E(Btu/h)--------------------------------------------------------------------------------------

kW1.9 1.9 1.9 2.1 3.2 4.2 1.8 2.1 2.5 2.5 2.8 3.0 3.2 3.4 3.7 4.1 4.2 4.4 4.8 5.1 5.3 5.3 5.3 5.3 5.3 5.3 5.3 2.6 3.0 3.4 3.4 3.7 3.7 3.9 4.1 4.1 4.2 4.4 4.6 4.6 4.8 4.9 4.9 5.1 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 3.5 3.9 4.2 4.2 4.6 4.6 4.8 4.9 4.9 4.9 5.1 5.3 5.3 5.3

Btu/h6,300 6,300 6,300 7,200

10,800 14,400 6,000 7,200 8,400 8,400 9,600 10,200 10,800 11,400 12,600 13,800 14,400 15,000 16,200 17,400 18,000 18,000 18,000 18,000 18,000 18,000 18,000 9,000 10,200 11,400 11,400 12,600 12,600 13,200 13,800 13,800 14,400 15,000 15,600 15,600 16,200 16,800 16,800 17,400 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 12,000 13,200 14,400 14,400 15,600 15,600 16,200 16,800 16,800 16,800 17,400 18,000 18,000 18,000

Btu/h5,000 7,000 9,000 12,000 18,000 24,000 10,000 12,000 14,000 14,000 16,000 17,000 18,000 19,000 21,000 23,000 24,000 25,000 27,000 29,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 15,000 17,000 19,000 19,000 21,000 21,000 22,000 23,000 23,000 24,000 25,000 26,000 26,000 27,000 28,000 28,000 29,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 20,000 22,000 24,000 24,000 26,000 26,000 27,000 28,000 28,000 28,000 29,000 30,000 30,000 30,000

kW1.52.12.63.55.37.12.93.54.14.14.75.05.35.66.26.87.17.47.98.58.88.88.88.88.88.88.84.45.05.65.66.26.26.56.86.87.17.47.67.67.98.28.28.58.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.85.96.57.17.17.67.67.98.28.28.28.58.88.88.8

Btu/h5,500 7,700 9,900 13,200 19,800 25,500 11,500 13,800 16,100 16,100 18,400 18,700 20,700 20,900 23,100 26,450 26,400 28,750 31,050 31,900 33,000 33,000 33,000 33,000 33,000 33,000 33,000 17,250 19,550 21,850 21,850 24,150 24,150 25,300 26,450 26,450 27,600 28,750 29,900 29,900 31,050 32,200 32,200 32,480 34,500 33,600 33,600 34,500 34,500 33,600 34,500 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 33,600 24,000 26,400 28,800 28,800 31,200 31,200 32,400 33,600 33,600 33,600 34,800 36,000 36,000 36,000

kW1.62.32.93.95.87.53.44.14.74.75.45.56.16.16.87.87.88.59.19.49.79.79.710.19.79.79.75.15.76.46.47.17.17.47.87.88.18.58.88.89.19.59.59.510.19.99.910.110.19.910.19.99.99.99.99.99.99.99.99.99.99.99.99.99.99.99.99.99.99.99.99.97.17.88.58.59.29.29.59.99.99.910.210.610.610.6

Min720 720 720 774

1,209 1,650 834 834 1,094 834 1,094 1,311 1,265 1,311 1,490 1,746 1,653 1,746 1,893 1,979 1,979 1,979 1,979 1,979 1,979 1,979 1,979 1,490 1,490 1,575 1,490 1,575 1,490 1,800 1,575 1,746 1,800 1,746 1,909 1,800 1,893 1,909 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948

Rated720 720 820 1,070 1,610 1,920 910

1,020 1,100 1,100 1,220 1,350 1,510 1,640 1,750 1,890 1,980 2,130 2,310 2,420 2,510 2,510 2,510 2,510 2,510 2,510 2,510 1,050 1,260 1,450 1,450 1,540 1,540 1,610 1,790 1,790 1,820 1,930 2,030 2,030 2,120 2,220 2,220 2,330 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 2,420 1,470 1,580 1,680 1,680 1,850 1,850 1,920 2,020 2,020 2,020 2,210 2,350 2,350 2,350

Max790 790

1,000 1,480 2,110

3,060 1,720 1,910

2,040 2,040 2,190 2,270 2,570 2,730 2,850 2,890 3,070 3,100 3,130 3,140 3,160 3,160 3,160 3,160 3,160 3,160 3,160 2,100 2,410 2,730 2,730 2,820 2,820 2,850 2,910 2,910 3,050 3,070 3,080 3,080 3,100 3,120 3,120 3,140 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 3,160 2,257 2,448 2,633 2,718 2,850 2,920 3,010 3,100 3,100 3,100 3,120 3,140 3,140 3,140

Min MaxRating

Operation Each Capacity

Cooling

Input (W)Total CapacityCombination of Indoor Unit (kBtu/h)

Page 29: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

LG Air Conditioners 2010 26_27

Note : 1. Cooling Capacity is based on : indoor temp.27°CDB, 19°CWB ; outdoor temp. 35°CDB2. Heating Capacity is based on : indoor temp.20°CDB ; outdoor temp. 7°CDB, 6°CWB3. The total ability of connected a indoor unit is up to 48kBtu/h4. At least two indoor units should be connected.

4Unit

5Unit

MU5M30 U40

UNIT-B77957759597795797579795127912971297912712955555555575775557757577557797557777957975795557799975577977

UNIT-A5755575755759557755977557977799775712955555555555575555755575555757555755755575595555775575555977

Total313232333333343435353536363737373839393939404141414243434445454546474748482527292931313233333334353536363737373838393939404040404141424242424343434444444445454546464646464647474748484848484548

UNIT-E

57979712997129712129991812129918121212991818121212129241812121812924181218181212121224241812121218

UNIT-D12991812121291812121291818121224181218122412181212181812182418182412185557775977777979975712997997999799121295799121297912979121212979129129

UNIT-C799597129799129979125997127129121291212971212912125555575577577579775757959779957977795799599591277999957912977

UNIT-A(Btu/h)4,839 6,563 4,688 4,545 4,545 6,364 4,412 6,176 4,286 4,286 6,000 4,167 7,500 4,054 4,054 5,676 5,526 3,846 3,846 6,923 5,385 5,250 3,659 3,659 5,122 6,429 4,884 4,884 4,773 6,000 6,000 4,667 4,565 3,191

4,468 7,500 5,625 5,000 5,000 5,000 5,000 4,839 4,839 4,688 4,545 4,545 4,545 4,412 4,286 6,000 4,167 4,167 4,054 4,054 5,676 3,947 3,947 3,846 5,385 3,846 3,750 3,750 3,750 5,250 3,659 5,122 3,571 3,571 3,571 5,000 3,488 3,488 4,884 3,409 3,409 3,409 4,773 3,333 3,333 6,000 3,261 3,261 3,261 3,261 4,565 4,565 3,191 3,191

4,468 3,125 3,125 3,125 3,125 5,625 4,667 4,375

UNIT-B(Btu/h)6,774 6,563 8,438 4,545 6,364 6,364 4,412 7,941 4,286 7,714

6,000 5,833 7,500 4,054 5,676 7,297 5,526 3,846 5,385 6,923 5,385 6,750 3,659 8,780 5,122 6,429 8,372 6,279 4,773 8,000 6,000 4,667 5,870 7,660 4,468 7,500 5,625 5,000 5,000 5,000 5,000 4,839 4,839 4,688 4,545 4,545 6,364 4,412 6,000 6,000 4,167 4,167 4,054 5,676 5,676 3,947 5,526 3,846 5,385 5,385 3,750 3,750 5,250 5,250 6,585 5,122 3,571 3,571 5,000 5,000 4,884 4,884 6,279 3,409 4,773 6,136 4,773 3,333 4,667 6,000 3,261 3,261 3,261 4,565 4,565 5,870 5,745 5,745 4,468 3,125 3,125 4,375 4,375 5,625 4,667 4,375

UNIT-C(Btu/h)6,774 8,438 8,438 4,545 8,182 6,364 10,588 7,941

6,000 7,714 7,714

10,000 7,500 7,297 5,676 7,297 9,474 3,846 6,923 6,923 5,385 9,000 5,122 8,780 6,585 8,571 8,372 6,279 8,182 8,000 6,000 4,667 7,826 7,660 5,745 7,500 7,500 5,000 5,000 5,000 5,000 4,839 6,774 4,688 4,545 6,364 6,364 4,412 6,000 6,000 4,167 5,833 7,297 5,676 5,676 3,947 5,526 3,846 5,385 6,923 3,750 6,750 5,250 5,250 6,585 6,585 3,571 5,000 6,429 5,000 4,884 4,884 6,279 3,409 4,773 6,136 6,136 3,333 6,000 6,000 3,261 5,870 7,826 4,565 4,565 5,870 5,745 5,745 5,745 3,125 4,375 5,625 7,500 5,625 4,667 4,375

UNIT-D(Btu/h)11,613 8,438 8,438 16,364 10,909 10,909 10,588 7,941

15,429 10,286 10,286 10,000 7,500 14,595 14,595 9,730 9,474

18,462 13,846 9,231

13,846 9,000 17,561 8,780 13,171 8,571 8,372 12,558 12,273 8,000 12,000 16,000 11,739 11,489 15,319 7,500 11,250 5,000 5,000 5,000 7,000 6,774 6,774 4,688 8,182 6,364 6,364 6,176 6,000 6,000 7,500 5,833 7,297 7,297 5,676 3,947 5,526 9,231 6,923 6,923 5,250 6,750 6,750 5,250 6,585 6,585 6,429 5,000 6,429 6,429 8,372 8,372 6,279 3,409 4,773 6,136 6,136 8,000 8,000 6,000 4,565 5,870 7,826 5,870 4,565 5,870 7,660 7,660 7,660 5,625 4,375 5,625 7,500 5,625 8,000 5,625

UNIT-E(Btu/h)-------------------------------------

5,000 7,000 9,000 7,000 8,710 6,774 11,250 8,182 8,182 6,364 10,588 7,714

6,000 10,000 10,000 7,297 7,297 7,297 14,211 9,474 9,231 6,923 6,923 13,500 9,000 9,000 9,000 6,585 6,585 12,857 12,857 8,571 8,571 8,372 8,372 6,279 16,364 12,273 8,182 8,182

12,000 8,000 6,000 15,652 11,739 7,826 11,739 11,739 7,826 7,660 7,660 7,660

15,000 15,000 11,250 7,500 7,500 8,000 11,250

kW5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 4.4 4.8 5.1 5.1 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3

Btu/h18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 15,000 16,200 17,400 17,400 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000

Btu/h30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 25,000 27,000 29,000 29,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000

kW8.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.87.47.98.58.58.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.88.8

Btu/h36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 30,000 32,400 34,800 34,800 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000

kW10.610.610.610.110.610.610.110.610.610.610.610.110.610.610.610.610.110.610.610.610.610.110.610.110.610.610.110.610.610.110.610.110.610.610.110.610.68.89.510.210.210.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.610.6

Min1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,948 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909 1,909

Rated2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 2,350 1,810 1,980 2,180 2,180 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300 2,300

Max3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 3,140 2,580 2,740 3,010 3,010 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110 3,110

Min MaxRating

Operation Each Capacity

Cooling

Input (W)Total CapacityCombination of Indoor Unit (kBtu/h)

Page 30: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Combination Table_

Note : 1.Cooling Capacity is based on : indoor temp.27°C DB, 19°C WB; outdoor temp. 35°C DB 2.Heating Capacity is based on : indoor temp.20°C DB; outdoor temp. 7°C DB, 6°C WB 3.The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values. 4.Total capacity index of indoor unit should be within 16~52 kBtu/h(40%~130%) 5.At least two indoor units should be connected.

16

18

19

21

23

24

25

26

27

28

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

MU5M40 UH0

Btu/h

9,600

10,800

11,400

12,600

13,800

14,400

15,000

15,600

16,200

16,800

18,000

18,600

19,200

19,800

20,400

21,000

21,600

22,200

22,800

23,400

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

kW

2.8

3.2

3.3

3.7

4.0

4.2

4.4

4.6

4.7

4.9

5.3

5.4

5.6

5.8

6.0

6.2

6.3

6.5

6.7

6.9

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

Btu/h

16,000

18,000

19,000

21,000

23,000

24,000

25,000

26,000

27,000

28,000

30,000

31,000

32,000

33,000

34,000

35,000

36,000

37,000

38,000

39,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

kW

4.7

5.3

5.6

6.2

6.7

7.0

7.3

7.6

7.9

8.2

8.8

9.1

9.4

9.7

10.0

10.3

10.5

10.8

11.1

11.4

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

Btu/h

18,400

20,700

21,850

24,150

26,450

27,600

28,750

29,900

31,050

32,200

34,500

35,650

36,800

37,950

39,100

40,250

41,400

42,550

43,700

44,850

45,000

45,000

45,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

kW

5.4

6.1

6.4

7.1

7.7

8.1

8.4

8.8

9.1

9.4

10.1

10.4

10.8

11.1

11.5

11.8

12.1

12.5

12.8

13.1

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

Min

1,038

1,107

1,136

1,244

1,317

1,420

1,459

1,501

1,536

1,593

1,688

1,696

1,755

1,788

1,872

1,944

2,020

2,106

2,144

2,173

2,178

2,190

2,190

2,190

2,190

2,190

2,178

2,178

2,178

2,178

2,178

2,178

2,178

Rating

1,730

1,845

1,894

2,074

2,195

2,366

2,432

2,502

2,560

2,655

2,814

2,826

2,925

2,980

3,120

3,240

3,366

3,510

3,574

3,621

3,630

3,650

3,650

3,650

3,650

3,650

3,630

3,630

3,630

3,630

3,630

3,630

3,630

Max

2,140

2,280

2,360

2,575

2,708

2,960

3,024

3,140

3,190

3,310

3,487

3,524

3,640

3,712

3,820

4,068

4,232

4,410

4,500

4,570

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

Min Rating Max

Total Indoor Unit Capacity(kBtu/h)

Cooling Capacity Input(W)

16

18

19

21

23

24

25

26

27

28

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

MU5M40 UH0

Btu/h

11,040

12,420

13,110

14,490

15,870

16,560

17,250

17,940

18,630

19,320

20,700

21,390

22,080

22,770

23,460

24,150

24,840

25,530

26,220

26,910

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

kW

3.2

3.6

3.8

4.2

4.6

4.9

5.1

5.3

5.5

5.7

6.1

6.3

6.5

6.7

6.9

7.1

7.3

7.5

7.7

7.9

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

Btu/h

18,400

20,700

21,850

24,150

26,450

27,600

28,750

29,900

31,050

32,200

34,500

35,650

36,800

37,950

39,100

40,250

41,400

42,550

43,700

44,850

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

kW

5.4

6.1

6.4

7.1

7.7

8.1

8.4

8.8

9.1

9.4

10.1

10.4

10.8

11.1

11.5

11.8

12.1

12.5

12.8

13.1

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

Btu/h

20,424

22,977

24,254

26,807

29,360

30,636

31,913

33,189

34,466

35,742

38,295

39,572

40,848

42,125

43,401

44,678

45,954

47,231

48,507

49,784

50,000

50,000

50,000

50,000

50,000

50,000

51,000

51,000

51,000

51,000

51,000

51,000

51,000

kW

6.0

6.7

7.1

7.9

8.6

9.0

9.4

9.7

10.1

10.5

11.2

11.6

12.0

12.3

12.7

13.1

13.5

13.8

14.2

14.6

14.7

14.7

14.7

14.7

14.7

14.7

14.9

14.9

14.9

14.9

14.9

14.9

14.9

Min

1,428

1,562

1,638

1,728

1,749

1,809

1,859

1,958

2,009

2,055

2,074

2,090

2,110

2,143

2,162

2,167

2,182

2,186

2,190

2,204

2,220

2,220

2,220

2,220

2,220

2,220

2,220

2,190

2,190

2,190

2,190

2,190

2,190

Rating

2,380

2,604

2,730

2,880

2,915

3,015

3,098

3,264

3,349

3,425

3,456

3,483

3,517

3,571

3,604

3,612

3,636

3,644

3,650

3,674

3,700

3,700

3,700

3,700

3,700

3,700

3,700

3,650

3,650

3,650

3,650

3,650

3,650

Max

2,642

2,860

3,004

3,292

3,346

3,412

3,540

3,705

3,818

3,980

4,165

4,234

4,312

4,464

4,585

4,606

4,655

4,745

4,770

4,811

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

Min Rating Max

Total Indoor Unit Capacity(kBtu/h)

Heating Capacity Input(W)

Page 31: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

LG Air Conditioners 2010 28_29

Note : 1.Cooling Capacity is based on : indoor temp.27°C DB, 19°C WB; outdoor temp. 35°C DB 2.Heating Capacity is based on : indoor temp.20°C DB; outdoor temp. 7°C DB, 6°C WB 3.The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values. 4.Total capacity index of indoor unit should be within 16~52 kBtu/h(40%~130%) 5.At least two indoor units should be connected.

16

18

19

21

23

24

25

26

27

28

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

FM40AH UH5

Btu/h

9,600

10,800

11,400

12,600

13,800

14,400

15,000

15,600

16,200

16,800

18,000

18,600

19,200

19,800

20,400

21,000

21,600

22,200

22,800

23,400

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

24,000

kW

2.8

3.2

3.3

3.7

4.0

4.2

4.4

4.6

4.7

4.9

5.3

5.4

5.6

5.8

6.0

6.2

6.3

6.5

6.7

6.9

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

7.0

Btu/h

16,000

18,000

19,000

21,000

23,000

24,000

25,000

26,000

27,000

28,000

30,000

31,000

32,000

33,000

34,000

35,000

36,000

37,000

38,000

39,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

40,000

kW

4.7

5.3

5.6

6.2

6.7

7.0

7.3

7.6

7.9

8.2

8.8

9.1

9.4

9.7

10.0

10.3

10.5

10.8

11.1

11.4

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

11.7

Btu/h

18,400

20,700

21,850

24,150

26,450

27,600

28,750

29,900

31,050

32,200

34,500

35,650

36,800

37,950

39,100

40,250

41,400

42,550

43,700

44,850

45,000

45,000

45,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

kW

5.4

6.1

6.4

7.1

7.7

8.1

8.4

8.8

9.1

9.4

10.1

10.4

10.8

11.1

11.5

11.8

12.1

12.5

12.8

13.1

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

Min

1,038

1,107

1,136

1,244

1,317

1,420

1,459

1,501

1,536

1,593

1,688

1,696

1,755

1,788

1,872

1,944

2,020

2,106

2,144

2,173

2,178

2,190

2,190

2,190

2,190

2,190

2,178

2,178

2,178

2,178

2,178

2,178

2,178

Rating

1,730

1,845

1,894

2,074

2,195

2,366

2,432

2,502

2,560

2,655

2,814

2,826

2,925

2,980

3,120

3,240

3,366

3,510

3,574

3,621

3,630

3,650

3,650

3,650

3,650

3,650

3,630

3,630

3,630

3,630

3,630

3,630

3,630

Max

2,140

2,280

2,360

2,575

2,708

2,960

3,024

3,140

3,190

3,310

3,487

3,524

3,640

3,712

3,820

4,068

4,232

4,410

4,500

4,570

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

4,652

Min Rating Max

Total Indoor Unit Capacity(kBtu/h)

Cooling Capacity Input(W)

16

18

19

21

23

24

25

26

27

28

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

FM40AH UH5

Btu/h

11,040

12,420

13,110

14,490

15,870

16,560

17,250

17,940

18,630

19,320

20,700

21,390

22,080

22,770

23,460

24,150

24,840

25,530

26,220

26,910

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

27,600

kW

3.2

3.6

3.8

4.2

4.6

4.9

5.1

5.3

5.5

5.7

6.1

6.3

6.5

6.7

6.9

7.1

7.3

7.5

7.7

7.9

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

8.1

Btu/h

18,400

20,700

21,850

24,150

26,450

27,600

28,750

29,900

31,050

32,200

34,500

35,650

36,800

37,950

39,100

40,250

41,400

42,550

43,700

44,850

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

46,000

kW

5.4

6.1

6.4

7.1

7.7

8.1

8.4

8.8

9.1

9.4

10.1

10.4

10.8

11.1

11.5

11.8

12.1

12.5

12.8

13.1

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

13.5

Btu/h

20,424

22,977

24,254

26,807

29,360

30,636

31,913

33,189

34,466

35,742

38,295

39,572

40,848

42,125

43,401

44,678

45,954

47,231

48,507

49,784

50,000

50,000

50,000

50,000

50,000

50,000

51,000

51,000

51,000

51,000

51,000

51,000

51,000

kW

6.0

6.7

7.1

7.9

8.6

9.0

9.4

9.7

10.1

10.5

11.2

11.6

12.0

12.3

12.7

13.1

13.5

13.8

14.2

14.6

14.7

14.7

14.7

14.7

14.7

14.7

14.9

14.9

14.9

14.9

14.9

14.9

14.9

Min

1,428

1,562

1,638

1,728

1,749

1,809

1,859

1,958

2,009

2,055

2,074

2,090

2,110

2,143

2,162

2,167

2,182

2,186

2,190

2,204

2,220

2,220

2,220

2,220

2,220

2,220

2,220

2,190

2,190

2,190

2,190

2,190

2,190

Rating

2,380

2,604

2,730

2,880

2,915

3,015

3,098

3,264

3,349

3,425

3,456

3,483

3,517

3,571

3,604

3,612

3,636

3,644

3,650

3,674

3,700

3,700

3,700

3,700

3,700

3,700

3,700

3,650

3,650

3,650

3,650

3,650

3,650

Max

2,642

2,860

3,004

3,292

3,346

3,412

3,540

3,705

3,818

3,980

4,165

4,234

4,312

4,464

4,585

4,606

4,655

4,745

4,770

4,811

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

4,843

Min Rating Max

Total Indoor Unit Capacity(kBtu/h)

Heating Capacity Input(W)

Page 32: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Note : 1.Cooling Capacity is based on : indoor temp.27°C DB, 19°C WB; outdoor temp. 35°C DB 2.Heating Capacity is based on : indoor temp.20°C DB; outdoor temp. 7°C DB, 6°C WB 3.The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values. 4.Total capacity index of indoor unit should be within 19~62k Btu/h(40%~130%) 5.At least two indoor units should be connected.

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

FM48AH U33

Btu/h

11,400

12,000

12,600

13,200

13,800

14,400

15,000

15,600

16,200

16,800

17,400

18,000

18,600

19,200

19,800

20,400

21,000

21,600

22,200

22,800

23,400

24,000

24,600

25,200

25,800

26,400

27,000

27,600

28,200

28,800

29,400

30,000

30,600

31,200

31,800

32,400

33,000

33,600

34,200

34,800

35,400

36,000

36,600

37,200

kW

3.3

3.5

3.7

3.9

4.0

4.2

4.4

4.6

4.7

4.9

5.1

5.3

5.5

5.6

5.8

6.0

6.2

6.3

6.5

6.7

6.9

7.0

7.2

7.4

7.6

7.7

7.9

8.1

8.3

8.4

8.6

8.8

9.0

9.1

9.3

9.5

9.7

9.8

10.0

10.2

10.4

10.5

10.7

10.9

Btu/h

19,000

20,000

21,000

22,000

23,000

24,000

25,000

26,000

27,000

28,000

29,000

30,000

31,000

32,000

33,000

34,000

35,000

36,000

37,000

38,000

39,000

40,000

41,000

42,000

43,000

44,000

45,000

46,000

47,000

48,000

48,343

48,686

49,029

49,372

49,715

50,058

50,401

50,744

51,087

51,430

51,773

52,116

52,459

52,800

kW

5.6

5.9

6.2

6.4

6.7

7.0

7.3

7.6

7.9

8.2

8.5

8.8

9.1

9.4

9.7

10.0

10.3

10.5

10.8

11.1

11.4

11.7

12.0

12.3

12.6

12.9

13.2

13.5

13.8

14.1

14.2

14.3

14.4

14.5

14.6

14.7

14.8

14.9

15.0

15.1

15.2

15.3

15.4

15.5

Btu/h

20,900

22,000

23,100

24,200

25,300

26,400

27,500

28,560

29,610

30,670

31,720

32,780

33,830

34,890

35,940

37,000

38,050

39,600

40,700

41,800

42,900

44,000

46,100

46,850

47,590

48,340

49,080

49,830

50,570

52,800

53,177

53,554

53,931

54,308

54,685

55,062

55,439

55,816

56,193

56,570

56,947

57,324

57,701

58,080

kW

6.1

6.4

6.8

7.1

7.4

7.7

8.1

8.4

8.7

9.0

9.3

9.6

9.9

10.2

10.5

10.8

11.2

11.6

11.9

12.2

12.6

12.9

13.5

13.7

13.9

14.2

14.4

14.6

14.8

15.5

15.6

15.7

15.8

15.9

16.0

16.1

16.2

16.4

16.5

16.6

16.7

16.8

16.9

17.0

Min

841

883

926

968

1,011

1,053

1,096

1,161

1,227

1,292

1,357

1,423

1,488

1,554

1,619

1,685

1,750

1,816

1,859

1,903

1,947

1,991

2,035

2,121

2,208

2,295

2,381

2,468

2,554

2,712

2,712

2,720

2,728

2,735

2,743

2,751

2,759

2,767

2,774

2,782

2,790

2,798

2,806

2,813

Rated

1,401

1,472

1,543

1,614

1,684

1,755

1,826

1,935

2,044

2,153

2,262

2,372

2,481

2,590

2,699

2,808

2,917

3,026

3,099

3,172

3,245

3,318

3,391

3,536

3,680

3,824

3,969

4,113

4,257

4,520

4,520

4,533

4,546

4,559

4,572

4,585

4,598

4,611

4,624

4,637

4,650

4,663

4,676

4,689

Max

1,611

1,693

1,774

1,856

1,937

2,019

2,100

2,225

2,351

2,476

2,602

2,727

2,853

2,978

3,104

3,229

3,355

3,480

3,564

3,648

3,732

3,816

3,900

4,066

4,232

4,398

4,564

4,730

4,896

5,062

5,062

5,077

5,077

5,106

5,121

5,135

5,150

5,164

5,179

5,350

5,350

5,350

5,350

5,350

Min Rating Max

Total Indoor Unit Capacity(kBtu/h)

Cooling Capacity Input(W)

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

FM48AH U33

Btu/h

12,768

13,440

14,112

14,784

15,456

16,128

16,800

17,472

18,144

18,816

19,488

20,160

20,832

21,504

22,176

22,848

23,520

24,192

24,864

25,536

26,208

26,880

27,552

28,224

28,896

29,568

30,240

30,912

31,584

28,800

29,400

30,000

30,600

31,200

31,800

32,400

33,000

33,600

34,200

34,800

35,400

36,000

36,600

37,200

kW

3.7

3.9

4.1

4.3

4.5

4.7

4.9

5.1

5.3

5.5

5.7

5.9

6.1

6.3

6.5

6.7

6.9

7.1

7.3

7.5

7.7

7.9

8.1

8.3

8.5

8.7

8.9

9.1

9.3

8.4

8.6

8.8

9.0

9.1

9.3

9.5

9.7

9.8

10.0

10.2

10.4

10.5

10.7

10.9

Btu/h

21280

22400

23520

24640

25760

26880

28000

29120

30240

31360

32480

33600

34720

35840

36960

38080

39200

40320

41440

42560

43680

44800

45920

47040

48160

49280

50400

51520

52640

54000

54143

54286

54429

54572

54715

54858

55001

55144

55287

55430

55573

55716

55859

56000

kW

6.2

6.6

6.9

7.2

7.5

7.9

8.2

8.5

8.9

9.2

9.5

9.8

10.2

10.5

10.8

11.2

11.5

11.8

12.1

12.5

12.8

13.1

13.5

13.8

14.1

14.4

14.8

15.1

15.4

15.8

15.9

15.9

15.9

16.0

16.0

16.1

16.1

16.2

16.2

16.2

16.3

16.3

16.4

16.4

Btu/h

22897

24014

25131

26249

27366

28483

29600

30869

32138

33407

34676

35945

37215

38484

39753

41022

42291

43560

44648

45736

46824

47912

49000

50484

51968

53452

54936

56420

57904

56000

56214

56428

56642

56856

57070

57284

57498

57712

57926

58140

58354

58568

58782

59000

kW

6.7

7.0

7.4

7.7

8.0

8.3

8.7

9.0

9.4

9.8

10.2

10.5

10.9

11.3

11.6

12.0

12.4

12.8

13.1

13.4

13.7

14.0

14.4

14.8

15.2

15.7

16.1

16.5

17.0

16.4

16.5

16.5

16.6

16.7

16.7

16.8

16.8

16.9

17.0

17.0

17.1

17.2

17.2

17.3

Min

1,301

1,350

1,399

1,448

1,497

1,546

1,643

1,696

1,748

1,800

1,852

1,904

1,957

2,009

2,061

2,113

2,165

2,217

2,264

2,306

2,347

2,386

2,452

2,473

2,508

2,544

2,579

2,614

2,650

2,685

2,720

2,756

2,791

2,826

2,847

2,911

2,922

2,736

2,736

2,736

2,736

2,739

2,655

2,658

Rated

2,168

2,250

2,332

2,413

2,495

2,576

2,739

2,826

2,913

3,000

3,087

3,174

3,261

3,348

3,435

3,522

3,609

3,696

3,774

3,843

3,911

3,977

4,087

4,122

4,181

4,239

4,298

4,357

4,416

4,475

4,534

4,593

4,652

4,710

4,745

4,852

4,870

4,560

4,560

4,560

4,560

4,565

4,425

4,430

Max

2,494

2,588

2,681

2,775

2,869

2,963

3,150

3,250

3,350

3,450

3,550

3,650

3,750

3,850

3,950

4,050

4,150

4,250

4,340

4,420

4,498

4,573

4,700

4,740

4,808

4,875

4,943

5,011

5,078

5,146

5,214

5,282

5,349

5,417

5,457

5,580

5,600

5,400

5,340

5,340

5,340

5,340

5,340

5,340

Min Rating Max

Total Indoor Unit Capacity(kBtu/h)

Heating Capacity Input(W)

Combination Table_

Page 33: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Note : 1.Cooling Capacity is based on : indoor temp.27°C DB, 19°C WB; outdoor temp. 35°C DB 2.Heating Capacity is based on : indoor temp.20°C DB; outdoor temp. 7°C DB, 6°C WB 3.The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values. 4.Total capacity index of indoor unit should be within 23~73 kBtu/h(40%~130%) 5.At least two indoor units should be connected.

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

FM56AH U33

Btu/h

13,800

14,400

15,000

15,600

16,200

16,800

17,400

18,000

18,600

19,200

19,800

20,400

21,000

21,600

22,200

22,800

23,400

24,000

24,600

25,200

25,800

26,400

27,000

27,600

28,200

28,800

29,400

30,000

30,600

31,200

31,800

32,400

33,000

33,600

34,200

34,800

35,400

36,000

36,600

37,200

37,800

38,400

39,000

39,600

40,200

40,800

41,400

42,000

42,600

43,200

43,800

kW

4.0

4.2

4.4

4.6

4.7

4.9

5.1

5.3

5.5

5.6

5.8

6.0

6.2

6.3

6.5

6.7

6.9

7.0

7.2

7.4

7.6

7.7

7.9

8.1

8.3

8.4

8.6

8.8

9.0

9.1

9.3

9.5

9.7

9.8

10.0

10.2

10.4

10.5

10.7

10.9

11.1

11.3

11.4

11.6

11.8

12.0

12.1

12.3

12.5

12.7

12.8

Btu/h

23,000

24,000

25,000

26,000

27,000

28,000

29,000

30,000

31,000

32,000

33,000

34,000

35,000

36,000

37,000

38,000

39,000

40,000

41,000

42,000

43,000

44,000

45,000

46,000

47,000

48,000

48,625

49,250

49,875

50,500

51,125

51,750

52,375

53,000

53,236

53,472

53,708

53,944

54,180

54,416

54,652

54,888

55,124

55,360

55,596

55,832

56,068

56,304

56,540

56,776

57,012

kW

6.7

7.0

7.3

7.6

7.9

8.2

8.5

8.8

9.1

9.4

9.7

10.0

10.3

10.5

10.8

11.1

11.4

11.7

12.0

12.3

12.6

12.9

13.2

13.5

13.8

14.1

14.2

14.4

14.6

14.8

15.0

15.2

15.3

15.5

15.6

15.7

15.7

15.8

15.9

15.9

16.0

16.1

16.2

16.2

16.3

16.4

16.4

16.5

16.6

16.6

16.7

Btu/h

25,300

26,400

28,000

29,060

30,110

31,170

32,220

33,280

34,330

35,390

36,440

37,500

38,550

39,600

40,700

41,800

42,900

44,000

46,100

46,850

47,590

48,340

49,080

49,830

50,570

51,320

52,060

52,810

53,550

54,300

55,050

55,800

56,850

57,900

58,900

59,170

59,440

59,710

59,980

60,250

60,520

60,790

61,060

61,330

61,600

61,870

62,140

62,410

62,680

62,950

63,200

kW

7.4

7.7

8.2

8.5

8.8

9.1

9.4

9.8

10.1

10.4

10.7

11.0

11.3

11.6

11.9

12.2

12.6

12.9

13.5

13.7

13.9

14.2

14.4

14.6

14.8

15.0

15.3

15.5

15.7

15.9

16.1

16.4

16.7

17.0

17.3

17.3

17.4

17.5

17.6

17.7

17.7

17.8

17.9

18.0

18.1

18.1

18.2

18.3

18.4

18.4

18.5

Min

1011

1053

1096

1161

1227

1292

1357

1423

1488

1554

1619

1685

1750

1816

1859

1903

1947

1991

2035

2083

2132

2180

2229

2277

2325

2374

2422

2471

2519

2568

2616

2713

2817

2896

2896

2896

2946

2946

2946

2946

2946

2946

2946

2946

2977

2977

2977

2977

2977

2977

2977

Rating

1684

1755

1826

1935

2044

2153

2262

2372

2481

2590

2699

2808

2917

3026

3099

3172

3245

3318

3391

3472

3553

3634

3714

3795

3876

3957

4037

4118

4199

4280

4360

4522

4696

4826

4826

4826

4910

4910

4910

4910

4910

4910

4910

4910

4961

4961

4961

4961

4961

4961

4961

Max

1937

2019

2100

2225

2351

2476

2602

2727

2853

2978

3104

3229

3355

3480

3564

3648

3732

3816

3900

3993

4086

4179

4271

4364

4457

4550

4643

4736

4829

4921

5014

5200

5400

5550

5650

5650

5650

5650

5650

5650

5650

5650

5650

5650

5650

5650

5650

5650

5650

5650

5650

Min Rating Max

Total Indoor Unit Capacity(kBtu/h)

Cooling Capacity Input(W)

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

FM56AH U33

Btu/h

15,456

16,128

16,800

17,472

18,144

18,816

19,488

20,160

20,832

21,504

22,176

22,848

23,520

24,192

24,864

25,536

26,208

26,880

27,552

28,224

28,896

29,568

30,240

30,912

31,584

28,800

29,400

30,000

30,600

31,200

31,800

32,400

33,000

33,600

34,200

34,800

35,400

36,000

36,600

37,200

37,800

38,400

39,000

39,600

40,200

40,800

41,400

42,000

42,600

43,200

43,800

kW

4.5

4.7

4.9

5.1

5.3

5.5

5.7

5.9

6.1

6.3

6.5

6.7

6.9

7.1

7.3

7.5

7.7

7.9

8.1

8.3

8.5

8.7

8.9

9.1

9.3

8.4

8.6

8.8

9.0

9.1

9.3

9.5

9.7

9.8

10.0

10.2

10.4

10.5

10.7

10.9

11.1

11.3

11.4

11.6

11.8

12.0

12.1

12.3

12.5

12.7

12.8

Btu/h

25,760

26,880

28,000

29,120

30,240

31,360

32,480

33,600

34,720

35,840

36,960

38,080

39,200

40,320

41,440

42,560

43,680

44,800

45,920

47,040

48,160

49,280

50,400

51,520

52,640

53,000

53,500

54,000

54,500

55,000

55,500

56,000

56,500

57,000

57,236

57,472

57,708

57,944

58,180

58,416

58,652

58,888

59,124

59,360

59,596

59,832

60,068

60,304

60,540

60,776

61,012

kW

7.5

7.9

8.2

8.5

8.9

9.2

9.5

9.8

10.2

10.5

10.8

11.2

11.5

11.8

12.1

12.5

12.8

13.1

13.5

13.8

14.1

14.4

14.8

15.1

15.4

15.5

15.7

15.8

16.0

16.1

16.3

16.4

16.6

16.7

16.8

16.8

16.9

17.0

17.0

17.1

17.2

17.3

17.3

17.4

17.5

17.5

17.6

17.7

17.7

17.8

17.9

Btu/h

27365

28482

29600

30869

32138

33407

34676

35945

37214

38483

39752

41021

42290

43560

44648

45736

46824

47912

49000

50286

51572

52858

54144

55430

56716

58000

58292

58584

58876

59168

59460

59750

60375

61000

61176

61353

61529

61706

61882

62059

62235

62412

62588

62765

62941

63118

63294

63471

63647

63824

64000

kW

8.0

8.3

8.7

9.0

9.4

9.8

10.2

10.5

10.9

11.3

11.6

12.0

12.4

12.8

13.1

13.4

13.7

14.0

14.4

14.7

15.1

15.5

15.9

16.2

16.6

17.0

17.1

17.2

17.3

17.3

17.4

17.5

17.7

17.9

17.9

18.0

18.0

18.1

18.1

18.2

18.2

18.3

18.3

18.4

18.4

18.5

18.5

18.6

18.7

18.7

18.8

1497

1546

1643

1696

1743

1791

1839

1887

1935

1983

2030

2078

2126

2217

2264

2311

2358

2405

2452

2487

2523

2558

2593

2629

2664

2699

2735

2770

2805

2841

2876

2911

2817

2736

2736

2736

2736

2739

2742

2745

2748

2751

2754

2757

2757

2757

2760

2763

2766

2769

2772

W

2495

2576

2739

2826

2906

2986

3065

3145

3225

3304

3384

3464

3543

3696

3774

3852

3930

4009

4087

4146

4205

4264

4322

4381

4440

4499

4558

4617

4676

4734

4793

4852

4696

4560

4560

4560

4560

4565

4570

4575

4580

4585

4590

4595

4595

4595

4600

4605

4610

4615

4620

2869

2963

3150

3250

3342

3433

3525

3617

3708

3800

3892

3983

4075

4250

4340

4430

4520

4610

4700

4768

4835

4903

4971

5038

5106

5174

5242

5309

5377

5445

5512

5580

5400

5340

5340

5371

5402

5433

5464

5495

5526

5557

5588

5650

5650

5650

5650

5650

5650

5700

5700

Min Min Rating MaxRating Max

Total Indoor Unit Capacity(kBtu/h)

Heating Capacity Input(W)

LG Air Conditioners 2010 30_31

Page 34: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

Notes

Page 35: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

LG Air Conditioners 2010 32_33

• Weekly program

• Turbo fan

• High head drain pump

• Low standby power

• Auto restart

• Central controller(accessory)

• Group control

• Child lock function

• Two thermistor control

• Auto changeover

• Long & high elevation piping

• Hot start

• Zone control (optional)

• Wireless remote controller

• Jet cool

• Auto operation

• 7-Hour off setting timer

• 24-Hour on/off setting timer

• Duct operation

Features _ icon

Page 36: LG Multi split Air Conditioners 2010 - Thermofrost Cryothermofrostcryo.co.uk/downloads/air-conditioning/lg-air... · LG Multi split Air Conditioners 2010 ... LG air conditioning units

LG Electronics Air Conditioning For more information, call: 01753 876 777 uk.lgeaircon.com

250 Bath Road,Slough, Berkshire SL1 4DX

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics Inc. Printed in the UK 2010

Information on the complete range of LG Air Conditioning commercial products is available on our website. You can also download a PDF file or request a hard copy to be sent. The design and specifications of products are constantly changing in the interest of improvement. Whilst every care has been taken in the preparation of this catalogue, some changes may have occurred since publication. LG Electronics cannot accept responsibility for errors and omissions.

LG Electronics UK Limited have been working closely with their supplier's to reduce their environmental impact on the world.