lifa air – air duct cleaning · lifa air® – air duct cleaning machines for air ducts and...
TRANSCRIPT
LIFA AIR® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning
2
Industrial processes always cause various by-products and contami-nants which need to be removed from exhaust systems and/or process pipelines regularly. Clean and functional exhaust/pipeline system also prevents fire hazards, cross-contamination and reduces energy consump-tion. Cleaning done with Lifa Air dry removal method saves both time andusage of chemicals and water, thus resulting into more economic and environmental friendly result.
RECOMMENDED EQUIPMENT• Combi Cleaner 40• Combi Cleaner 15• Hydmaster 40• Special Cleaner 25 Multi• Duct Control Cleaning Robot
I N D U S T R I A L E X H A U S T D U C T S A N D P R O C E S S P I P E S
Hydmaster 40Electric-hydraulic brushing machine
for 400 - 1200 mm ducts
Reference examples:Food processingAutomotive manufacturiingWood, paper and pulp industriesMedicine and other clean room technologie
Before After
Grease accumulation in exhaust ducts is a fire danger which can cause the whole building to be damaged. Therefore ducts need to cleaned regularly – as per how many hours kitchen is used per day – in order to keep this accumulation = threat in minimum at all times. Clean and functional exhaust system also prevents odours and heat rise from escaping to other areas.
RECOMMENDED EQUIPMENT• Combi Cleaner 40• Combi Cleaner 15• Hydmaster 40• Special Cleaner 25 Multi• Extra strong driller shafts
K I T C H E N E X H A U S T G R E A S E
Combi Cleaner 40Pneumatic brushing machine
for 400 - 1200 mm ducts
Reference examples:Hamburger restaurants (all global brands, all over the world)Hotel kitchens (all global brands, all over the world)Italian restaurants
Before After
3
4
HVAC systems in commercial buildings need to be regularly inspected and cleaned in order to keep the building - and it’s occupants - healthy. Unfortunately due to lack of maintenance and energy savings ventilation systems actually are too often the very cause for Sick Building Syndrome (SBS) and Building Related Illness (BRI).
RECOMMENDED EQUIPMENT• Combi Cleaner 40• Combi Cleaner 15• Hydmaster 40• Special Cleaner 25 Multi• Duct Control Cleaning Robot
C O M M E R C I A L M U L T I - S T O R E YB U I L D I N G S
Special Cleaner 25 MultiElectric brushing machine for 250 - 800 mm ducts
Reference examples:HospitalsOffice buildingsSchool and kindergartenResidential blocks or flats
Before After
Dryer vents is by far the greatest risk of fire in relation to HVAC in residen-tial houses. Secondly, kitchen exhaust ductwork. However, in long term, dust accumulated in ducts, heat exhagers etc. will be the source microbial growth (mold/mildew) and/or increase the amount of energy usage.
RECOMMENDED EQUIPMENT• Combi Cleaner 40• Special Cleaner 20• Driller shafts
R E S I D E N T I A L H O U S E S
Special Cleaner 20Electric brushing machine
for ø 100 - 400 mm ducts
Reference examples:Single housesTerraced houses
Before After
5
6
Large ducts Small ducts
Hydmaster 40 Combi Cleaner 40 Special Cleaner 25 Multi
Duct Control Cleaning Robot
Special Cleaner 20 Combi Cleaner 15
Operating power Electric-hydraulic Compressed air Electricity Compressed air (brush) + electricity (driving)
Electricity Compressed air
Operating voltage and frequency
240 VAC (or 110-120 VAC), 1~, 50/60 Hz
- 240 VAC (or 110-120 VAC), 1~, 50/60 Hz
12 VCD 240 VAC (or 110-120 VAC), 1~, 50/60 Hz
-
Motor 1,1 kW (1,5 HP)
0,4 kW(0,6 HP)
0,75 kW (1,0 HP)
0,11 kW (0,15 HP)
0,37 kW (0,5 HP)
0,11 kW (0,15 HP)
Fuse 16 A - 10 A 5 A 10 A -
Max. torque 10 Nm 6,5 Nm 5 Nm 3 Nm 5 Nm 3 Nm
Brush connection
M12 M12 M12 M12 M12 M12
Brush size recommendation
400 - 1200 mm 400 - 1200 mm 250 - 800 mm 200 - 600 mm 100 - 400 mm 160 - 600 mm
Brush rotation speed
Continuous adjustment, 225 - 880 rpm
Continuous adjustment, max. 670 rpm
Continuous adjustment, 225 - 580 rpm
Continuous adjustment, max. 1000 rpm
Continuous adjustment, 225 - 580 rpm
Continuous adjustment, max. 1000 rpm
Rotation controls Foot pedal, remote hand control
Manual / Air Valve
Foot pedal, remote hand control (accessory)
Manual / Air Valve Foot pedal / remote hand control (acces-sory)
Manual / Air Valve
Nozzle connection - Quick coupling Quick coupling Quick coupling - Quick coupling
Air volume consumption
- 400 l/min., 7 bar Nozzle type dependant
340 l/min., 7 bar - 340 l/min., 7 bar
Measurements (mm)
H: 1290L: 1100W: 570
H: 1290L: 1100W: 570
H: 1290L: 1100W: 570
H: 190L: 410W: 280
H: 910L: 640W: 480
H: 910L: 640W: 480
Weight 93 kg 45 kg 71 kg 8 kg 38 kg 17 kg
Cleaning shaft 40 m 40 m 25 m 25 m (driving cable)
20 m 15 m
Accessories Y-gear, 3-brush-gear, mechanical cente-ring device, hand controller
Y-gear, 3-brush-gear, mechanical centering device, hand controller
Y-gear,mechanical centering device, hand controller, spray bottle, nozzles
Y-gear, 3-brush-gear, spray bottle, nozzles
Mechanical cente-ring device, hand controller
Y-gear,mecha-nical centering device, hand controller, spray bottle, nozzles
Scope
MEZ-TECHNIK GmbHBierwiesenstrasse 772770 Reutlingen
Tel.: +49 (7072) 600980Fax: +49 (7072) 6009860