lighthouse worldwide solutions master presentation
TRANSCRIPT
![Page 1: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/1.jpg)
www.golighthouse.com
Lighthouse Worldwide Solutions
Master Presentation
![Page 2: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/2.jpg)
www.golighthouse.com
Fremont, CA
R&D
Engineering
Pilot Production
Executive Management
R&D / Headquarters / Manufacturing
Medford, OR
Manufacturing
Service & Repair Center
Central Calibration Lab
RMA Center
Medford, OR
Fremont, CA
![Page 3: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/3.jpg)
www.golighthouse.com
New Headquarters: Silicon Valley
![Page 4: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/4.jpg)
www.golighthouse.com
Lighthouse Focus on Quality ISO 9001:2000 Facilities
United States:
Medford, OR
San Jose, CA
The
Netherlands:
Alphen Singapore
5 Lighthouse Locations are ISO 9000 Registered
Thailand
![Page 5: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/5.jpg)
www.golighthouse.com
Lighthouse Worldwide Solutions
Pharmaceutical Capabilities:
Particle counters and facility monitoring systems for meeting cGMP monitoring regulations
21 CFR Part 210 & 211
21 CFR Part 11
EU GMP Annex 1
PIC/S Annex 1
WHO Guidelines
USP 788/797
Systems designed for compliance
Project management services
Installation services
Validation services
Service, repair, retrofit of monitoring systems
Calibration per ISO 21501 standards
Contamination control consulting and training
![Page 6: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/6.jpg)
www.golighthouse.com
Monitoring Solutions
Air Particle
Liquid Particle
Temperature
Humidity
Differential Pressure
Electrostatic Charge
Air Velocity
TOC
General Monitoring
Current on FFU’s
Chillers/Refrigerators
Door Switches
Oven Temp
Dry Box Humidity
Gas Purity
Incubators
Large LCD Displays
Specific Applications
![Page 7: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/7.jpg)
www.golighthouse.com
Lighthouse Systems Experience
Lighthouse experience in FMS system installation, particle counter integration and software
Over 200 FMS system installations worldwide
Lighthouse is the number one shipper of remote particle counters (numbers exceeding 900 units / month)
![Page 8: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/8.jpg)
www.golighthouse.com
Boston Scientific
Pharmaceutical Customers
![Page 9: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/9.jpg)
www.golighthouse.com
Lighthouse Pharma Customers (System)
Baxter System
ROCHE
Sandoz
Bimagen
Beta Plus Pharma
Budelpack NV
Galapagos NV
Helvoet Pharma Belgium NV
Mediline NV
Salvamed
Novo Nordisk
Styker Howmedica –system
West Pharmaceuticals
Hospira / Abbott
GE Healthcare – system
Kabi Fresenius
Biogalenica
Favea
Vericore
Jugoremedia
Octapharma
Q- Med
Alcomed BV
Large multi-building Pharma system which consists of particles counters and
environmental sensors. These sensors are integrated to the FMS software with alarm
beacons.
![Page 10: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/10.jpg)
www.golighthouse.com
Lighthouse Pharma Customers (System) – Cont’d
Crucell
Dutch Veterian Institute
Fresenius Hemocare BV
Mallinckodt Medical/ Tyco
Microclean B.V
Nelipak / Seal Air
Sandoz
Schenker International
TNO –Dimes
ACE Pharmaceuticals
Allergy Therapeutics – system
Aston University (Mayne-Parma)
Astra Zeneca – system
Baxter system
Glan Clywdd Hospital
Medtronic
Glaxo Smith Kline – system
NIBSC Stem Cell Bank
Pfizer-system
University College London system
Vericore (Novartis) –system
Astra Zeneca – system
Bassaire
IBA Molecular
Amgen
Chiron
Organogenisis
Pharmaforce
Cell Genesys
McGuff Pharma
MDS Nordion
![Page 11: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/11.jpg)
www.golighthouse.com
Products
![Page 12: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/12.jpg)
www.golighthouse.com
World’s Number One Particle Counters!
Lighthouse Family of Products
![Page 13: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/13.jpg)
www.golighthouse.com
Remote Particle Counters
![Page 14: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/14.jpg)
www.golighthouse.com
Remote Particle Counters
Largest selection of remote particles
counters available
Variety of outputs
Modbus ASCII
4-20mA
RS-485 (Met One Protocol)
Ethernet
Sensitivity from 0.1µM
Flow-rates 0.1 CFM, 1.0 CFM
(4) Series includes flow sensor
Remote vacuum or self-contained pump
units
Temp / RH probe options
Hydrogen peroxide resistant
![Page 15: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/15.jpg)
www.golighthouse.com
Extreme Lifetime Infrared Technology Emitter (ELITE) higher power Laser Diode
Optical communications grade Laser Diode
Packaged and tested for Lighthouse products
Accelerated tests performed to verify lifetime
Extends lifetime of Laser Diode based products to an estimated 20-50 years based upon accelerated test results on all products
ELITE Sensor Technology
Slide 28
Accelerated Tests
at 75 Degrees
Celsius and Full
Power
![Page 16: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/16.jpg)
www.golighthouse.com
REMOTE X104 ELITE Sensor
(Optional) Temperature and
Humidity Probe
Intelligent Alarm
Relay for Tool
Shut Down
Power LED
Flow LED
Sampling LED
Service LED
From 0.2µm Detection
2 - 4 Channel
Status Output:
* Flow Status
* Sensor Serial #
* Calibration Date
* Laser Voltage
* Background Voltage
Industry Standard
MODBUS or
Ethernet Protocol
>20 Year Laser Life
True Flow
Detection &
Status
![Page 17: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/17.jpg)
www.golighthouse.com
REMOTE X104 ELITE Sensor
Self-diagnostics
The Lighthouse Remote 4 Series particle counter has the most complete self diagnostics of
any sensor on the market today.
Self-diagnostics help to ensure data accuracy and reliability.
Self-diagnostics include:
* Laser voltage
* Laser background voltage
* Laser Diode failure
* Photo amp failure
* Photo Diode failure
* Flow status
![Page 18: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/18.jpg)
www.golighthouse.com
Remote 5104V VHP, IPA, LpH, Vesphene and Spor-Klenz
compatible
Class 1 Division 2 Rating
Built-in flow monitoring
0.5 - 5.0 μm
1.0 cfm (28.3 LPM) flow rate
Designed for ISO21501-4 compliance
Small size
Stainless steel, wash down resistant / splash-tight
enclosure
20 year laser life
![Page 19: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/19.jpg)
www.golighthouse.com
Remote 5104V
Mounting
Tabs
Smoothed
Surface
Sealed Inlet
Sealed
Connectors
316L Stainless
Steel
Wipedownable
Case
VHP
Compatible
VHP, IPA, LpH, Vesphene and Spor-Klenz Compatible
![Page 20: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/20.jpg)
www.golighthouse.com
Remote 5104PN & 5102PN
Remote 5104PN: Modbus
Remote 5102PN: 4-20mA
1.0 CFM (28.3 LPM) flow rate
Built-in pump
Filter pump exhaust
Pump start / stop via software
(5104PN)
Stainless steel construction
Wipe-down enclosure
90-240 VAC Power (50/60Hz)
![Page 21: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/21.jpg)
www.golighthouse.com
Remote 5104PN
Channel sizes: 0.5 - 5.0μm
1.0 cfm (28.3 LPM) flow rate
Internal vacuum pump with flow control
Designed for ISO21501-4 compliance
NEMA style stainless steel enclosure
LED status indicators
VHP, IPA, LpH, Vesphene and Spor-Klenz
compatible
20 year laser life
![Page 22: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/22.jpg)
www.golighthouse.com
Remote 5104PN
0.2 micron
Filtered
Exhaust
Built in
Pump
Sealed
Inlet
Sealed
Connectors
Wipedownable
Case
316L Stainless
Steel
VHP, IPA, LpH, Vesphene and Spor-Klenz Compatible
![Page 23: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/23.jpg)
www.golighthouse.com
Remote 5104P & 3104P
Remote particle counter w/pump
Supports remote display
Interface: USB, RS-485 or Ethernet
HEPA filter cooling fan exhaust and pump
exhaust
Interface with manifold
32 Port
6 Port
Reduced cost for manifold systems
![Page 24: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/24.jpg)
www.golighthouse.com
Remote 50104H (Remote Boulder Counter)
Remote 50104H (remote Boulder Counter for hazardous
environments Class 1 Division 2)
(Five-Zero-One-Zero-Four H)
5 to 100µm remote particle counter
1.0 CFM with flow monitoring
4 channels
For use in Auto Manufacturing, Aerospace
and other industrial applications
![Page 25: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/25.jpg)
www.golighthouse.com
Portable Cart System
Real time monitoring of
multiple locations
Troubleshoot the process
Identify particle sources
quickly
Characterize the process
Qualify the equipment
![Page 26: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/26.jpg)
www.golighthouse.com
Portable Cart System
![Page 27: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/27.jpg)
www.golighthouse.com
Manifolds
Universal Manifold
32 sample locations
1.0 cfm
Works with Lighthouse and Met One particle counters
Mini-Manifold
6 sample locations
0.1 cfm
4 analog inputs
Mini-Manifold+
6 sample locations
1.0 cfm
Mini-Manifold
&
0.2 Micron
Particle
Counter
FanHEPA / ULPA
Filter
Particle Shedding /
Generation
Mini-Environment Monitoring
With Mini-Manifold & Single
Particle Counter
![Page 28: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/28.jpg)
www.golighthouse.com
Online Remote Viable Sampling
![Page 29: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/29.jpg)
www.golighthouse.com
Active Air Samplers
Similar to sieve impactor; cover contains uniformly spaced orifices; vacuum draws in air which is
impacted on agar plate
![Page 30: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/30.jpg)
www.golighthouse.com
Principle of Operation
Similar to sieve impactor; cover contains uniformly spaced
orifices; vacuum draws in air which is impacted on agar plate
![Page 31: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/31.jpg)
www.golighthouse.com
Impaction on Media Plate
![Page 32: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/32.jpg)
www.golighthouse.com
Remote Viable Sampling Systems
Remote SMA
Allows for not violating Grade A
conditions for sampling
SMA is in Grade B environment:
with tube to Isokinetic probe for
Grade A sampling
![Page 33: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/33.jpg)
www.golighthouse.com
Active Air Samplers
Provides for starting and sampling from inside
the room
![Page 34: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/34.jpg)
www.golighthouse.com
Active Air Samplers
![Page 35: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/35.jpg)
www.golighthouse.com
Lighthouse Installation Pictures
![Page 36: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/36.jpg)
www.golighthouse.com
Viable Sampling
Lighthouse Installation Pictures
![Page 37: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/37.jpg)
www.golighthouse.com
Viable Sampling
Lighthouse Installation Pictures
![Page 38: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/38.jpg)
www.golighthouse.com
Remote Viable Sampling Systems
Remote microbial sampling system
Utilizing microbial agar impactors
Controlled via FMS monitoring computer system
Internal pump or external
![Page 39: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/39.jpg)
www.golighthouse.com
Combined Online
Viable and Non-Viable Sampling
![Page 40: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/40.jpg)
www.golighthouse.com
Remote Viable / Non Viable Sampling Systems
Combined viable and non-viable sampling
1.0 cfm flow rate
Particle sampling at 0.5 and 5.0 micron
Controlled locally or via software
Internal or external vacuum
![Page 41: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/41.jpg)
www.golighthouse.com
Remote Viable/Non Viable Sampling Systems
Individually Controlled
Regulated Flow
Viable Non-Viable
![Page 42: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/42.jpg)
www.golighthouse.com
Installation
Particle
Viable
Combined
Viable / Non-
Viable
Sampling
![Page 43: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/43.jpg)
www.golighthouse.com
SMA Control Interface: Example
Duration will allow the user to click on the text box and
select one of the preset sample times for the individual SMA.
Time remaining will show how much time is left for
the sample.
Air flow will show the flow rate of the sample taking
place.
Start will start the sampling process.
Reset will reset the time remaining to the preset
sample time selected.
Start / stop require password entry
![Page 44: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/44.jpg)
www.golighthouse.com
SMA Control Interface: Example
Manual data can be integrated into an existing record.
Input
Date
Start/Stop Time
Description
Flow Rate
Volume
CFU
![Page 45: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/45.jpg)
www.golighthouse.com
Online Monitoring Systems
![Page 46: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/46.jpg)
www.golighthouse.com
Vacuum Systems
![Page 47: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/47.jpg)
www.golighthouse.com
Online Systems – Star Configuration
Alarm
Light
TRH
Sensor
DP
Sensor
Optional Items Vacuum
pump
Vacuum Gauge
Vacuum Manifold
6 Real Time Particle Counters with External Vacuum Pump
Data Hub
- Ethernet or Modbus Output
- Supplies Power to Remotes
RS-485 MODBUS
Real Time
Software
Power From
Data Hub
![Page 48: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/48.jpg)
www.golighthouse.com
Online Systems- Network Configuration
4 Real Time Particle Counters with Built in Vacuum Pump
Over Ethernet
Real Time
Software
Built in Vacuum
Pumps
LAN
Power
and Ethernet
eth
ern
et
psPower
and Ethernet
eth
ern
et
ps Power
and Ethernet
eth
ern
et
ps Power
and Ethernet
eth
ern
et
ps
View
Station
View
Station
Alarm
Light
TRH
Sensor
DP
Sensor
Optional Items
![Page 49: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/49.jpg)
www.golighthouse.com
Online Systems- Network Configuration
![Page 50: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/50.jpg)
www.golighthouse.com
Online Systems- Network Configuration
![Page 51: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/51.jpg)
www.golighthouse.com
Online Systems- Network Configuration
![Page 52: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/52.jpg)
www.golighthouse.com
Plug and Play
![Page 53: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/53.jpg)
www.golighthouse.com
Online Manifold Systems
Alarm
Light
TRH
Sensor
DP
Sensor
Optional Items
Manifold Sampling System
RS-485 MODBUS
Real Time
Software
Particle Counter and
Sequential Sampling Manifold
Up to 32 Sample Ports
Data Hub
- Ethernet or Modbus Output
![Page 54: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/54.jpg)
www.golighthouse.com
![Page 55: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/55.jpg)
www.golighthouse.com
Online System with Server
![Page 56: Lighthouse Worldwide Solutions Master Presentation](https://reader031.vdocument.in/reader031/viewer/2022030101/621c5d87085c0d50b9226d80/html5/thumbnails/56.jpg)
www.golighthouse.com
Thank You