lighting control 53...univ: 1-16 (16) supernode add: 1 risk of electric shock. disconnect power...
TRANSCRIPT
1. All consoles, NPU’s, 3d Computers MUST have the same software loaded!. 2. Connected consoles should be used to program to mitigate the risk of the Master console failing during output. 3. Add 1 millisecond to both the Artnet and sACN output ‘delay' fields in "setup/networking/network protocols"4. sACN protocol field should be set to “FINAL” in ”setup/networking/network protocols"5. Ethernet Port 1(eth 0) is MA/sACN Net and Ethernet Port 2 (eth 1) is Artnet Only!6. Spare NPU's are NOT spare if they are plugged in. The MA shares the processor load across all NPU's on the network. Ensure system can operate without spare first, then add spare to network which will take the load if any NPU fails.7. NPUs generate a high level of network traffic. Use the lowest number of NPUs required for parameter count. 8. Only the Master Console in a session will listen/send sACN/Artnet. 9. DISABLE “Network DMX if Alone” within Network Protocols menu. 10. Priority levels must be set in order to retain station configuration. 11. Artnet data corruption can occur if a previous master and new master are both connected to the Artnet network.12. Do NOT use RDM in show conditions. DMX data is not reliable while RDM is discovering and may not be compatible with S400.13. Any MA 3D, onPC, or other MA device that is powered down MUST be physically unplugged from network!!14. Rob Base Lesson #2...It takes two to make it outta sight!
MA2 Special Notes
1. All Fiber Optic runs, regardless of overall length, MUST NOT be made up of more then five lengths of cable2. NO ETHERCON or CAT5E COUPLERS!!3. S400 Supernodes should be set to “Merge2” to avoid any conflicts during a system failure. 4. Do NOT use RDM in show conditions. DMX data is not reliable while RDM is discovering If RDM must be used, leave “incremental” unchecked. 5. All VIA 12 switches MUST have the same software loaded and have unique IP addresses6. All switches should be defaulted inc Network Settings prior to configuration. 7. All VIA 12 Port Speeds should be set to “Auto Negotiate” 8. VLAN = Virtual Local Area Network (VLANS are like groups they only talk to other ports configured as the same VLAN9. Managment VLAN = 1.10. When using VLAN’s Ports 11-12 (Cat5e on rear) and Ports 13-14 (Fiber Ports) must be set to TAGGED/UPLINK so as to pass ALL VLAN traffic10. Rob Base Lesson #1...It takes two to make a thing go right.
Important System Notes!
Pete V676 PreVis
Supernode Add: 5
Supernode Add: 4
Supernode Add: 3
Supernode Add: 2
Supernode Add: 1
7-Port Switch V676
7-Port Switch Artnet
LiteConverse
Cat 5e (Artnet)
PETE’S PREVISOF PLEASURE
LIGHTING CONTROL LAYOUT
COUNTS
Cat 5e (Artnet)
OptiCon DuoFiber
Cat 5e(MA Artnet)
KEY
Cat5e(V676)
SUPERBOWL Halftime
LX NETWORK
DATE: 1/23/19 0922 SCALE: VISUAL ONLY
DRAWN BY: CONTI ©2019 PRG
REV E
350’ Limo Fiberx8 Active & Spare
VIA12 Switchx22 Active & SpareU506K
S400 Rackx7 Active 3838T-
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
NodePlusx14 Active & Spare37999-
SuperNodex223799C-
10-PortSwitchx11 Active & Spare3132K-
350’ OptiCon Duo Fiberx4 Active & Spare
600’ OptiCon Duo Fiberx10 Active & Spare
Spare OptiCon DuoFiber
250’ OptiCon Duo Fiberx10 Active & Spare
OptiCon Duo Couplersx8 Active & Spare
Limo Fiber
Cat 5e(MA/ sACN Net)
Cat 5e (UPLINK)
SpareLimo Fiber
FOH MovesLike Jagger
Pete V676 Main
Univ: 46-55 (10)
Supernode Add: 5
Univ: 36-45(10)
Supernode Add: 4
Univ: 25-35 (11)
Supernode Add: 3
Univ: 17-24 (8)
Supernode Add: 2
Univ: 1-16 (16)
Supernode Add: 1
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
VIA12 Gigabit SwitchIP Add: 10.66.201.001
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
SessionID: 1 SBLII
SPARE
grandMA 2 Lite: JasonMAIN (High)eth0 Add: 192.168.0.1eth1 Add: 10.66.0.1
Pete V676 Backup
Cat 5e (v676)
Node Plus FILTER
(S400 Mode)Add:11
Univ: 98,99,x,x,x,x
grandMA 2 Lite: PYRO MAIN (High)eth0 Add: 192.168.0.201eth1 Add: 10.66.0.201
grandMA 2 Lite: JasonSPARE (Normal)eth0 Add: 192.168.0.2eth1 Add: 10.66.0.2
VIA12 Gigabit SwitchIP Add: 10.66.201.002
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
S400 ToolsIP Add:10.66.200.1
Cat 5e (Artnet)
10-Port Switch
VIA12 Gigabit SwitchIP Add: 10.66.248.001
VIA12 Gigabit SwitchIP Add: 10.66.248.002
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
SPARE
Cat 5e (MA Artnet)
VIA12 Gigabit SwitchIP Add: 10.66.201.003VLAN 1: V676 Artnet Ports 1-5VLAN 2: MA/sACN ports 6-10UPLINK: All Data Ports 11-14 VIA12 Gigabit Switch
IP Add: 10.66.248.003VLAN 1: V676 Artnet Ports 1-5VLAN 2: MA Artnet Ports 6-10UPLINK: All Data Ports 11-14
SPARE
CATWALK SWITCHES
SUITES & 200 LEVEL SWITCHES
FIELD SWITCHES
West Truss
Cat 5e (Artnet)
Univ: 56-64 (9)
Supernode Add: 6
Cat 5e (v676)
Cat 5e (v676)
Cat 5e (v676)
Cat 5e (Artnet)
Cat 5e (Artnet)
10-Port Switch
Cat 5e (Artnet)
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Hippo 1: 192.168.0.31Artnet IP: 10.66.0.31
IP Add: 192.168.0.11NPU #1
IP Add: 192.168.0.12NPU #2
IP Add: 192.168.0.13
NPU #3
NW-DSL Field Rack
Univ: 47,48,53,x,x,x,98,99
Addr: 711Supernode (S400 Mode)
Cat 5e (Artnet)
VIA12 Gigabit SwitchIP Add: 10.66.207.011VLAN 1: V676 Artnet Ports 1-5VLAN 2: MA/sACN ports 6-10UPLINK: All Data Ports 11-14
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Supernode (S400 Mode)
VIA12 Gigabit SwitchIP Add: 10.66.247.011VLAN 1: V676 Artnet Ports 1-5VLAN 2: MA/sACN ports 6-10UPLINK: All Data Ports 11-14
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Cat 5e (Artnet)
NE-DSR Field Rack
Univ: 52,x,x,x,x,x,98,99
Addr: 721Supernode (S400 Mode)
Cat 5e (Artnet)
Univ: 52,x,x,x,x,x,x,98,99
VIA12 Gigabit SwitchIP Add: 10.66.207.021VLAN 1: V676 Artnet Ports 1-5VLAN 2: MA/sACN ports 6-10UPLINK: All Data Ports 11-14
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Addr: 722Supernode (S400 Mode)
VIA12 Gigabit SwitchIP Add: 10.66.247.021VLAN 1: V676 Artnet Ports 1-5VLAN 2: MA/sACN ports 6-10UPLINK: All Data Ports 11-14
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Cat 5e (Artnet)
PathfinderIP Add: 192.168.0.51
SE-USR Field Rack
Univ: 40,41,46,47,48,52,x,x
Addr: 735Supernode (S400 Mode)
Univ: 56,57,58,59,36,37,38,39
VIA12 Gigabit SwitchIP Add: 10.66.207.031VLAN 1: V676 Artnet Ports 1-5VLAN 2: MA/sACN ports 6-10UPLINK: All Data Ports 11-14
Addr: 734Supernode (S400 Mode)
VIA12 Gigabit SwitchIP Add: 10.66.247.031VLAN 1: V676 Artnet Ports 1-5VLAN 2: MA/sACN ports 6-10UPLINK: All Data Ports 11-14
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Univ: 40,41,46,47,48,52,x,x
Addr: 732Supernode (S400 Mode)Supernode (S400 Mode)
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Univ: 56,57,58,59,36,37,38,39
Addr: 731
SW-USL Field Rack
Univ: 49,50,51,53,x,x,98,99
Addr: 744Supernode (S400 Mode)
VIA12 Gigabit SwitchIP Add: 10.66.207.041VLAN 1: V676 Artnet Ports 1-5VLAN 2: MA/sACN ports 6-10UPLINK: All Data Ports 11-14
Addr: 743Supernode (S400 Mode)
VIA12 Gigabit SwitchIP Add: 10.66.247.041VLAN 1: V676 Artnet Ports 1-5VLAN 2: MA/sACN ports 6-10UPLINK: All Data Ports 11-14
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Cat 5e (Artnet)
Addr: 742Supernode (S400 Mode)Supernode (S400 Mode)
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Cat 5e (Artnet)
Univ: 60,61,62,63,42,43,44,45
Addr: 741
CART #25
S400 Rack 111 S400 Rack 121
VIA12 Gigabit SwitchIP Add: 10.66.207.111VLAN 1: V676 Artnet Ports 1-10UPLINK: All Data Ports 11-14
VIA12 Gigabit SwitchIP Add: 10.66.247.111VLAN 1: V676 Artnet Ports 1-10UPLINK: All Data Ports 11-14
SPARERisk of electric shock.
Disconnect powerbefore opening.
Risque de dechargeelectrique. Debrancher
le pouvoir avantd'ouvrier.
90-260VAC.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
S400 Rack 211
North Truss
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
VIA12 Gigabit SwitchIP Add: 10.66.201.021
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
VIA12 Gigabit SwitchIP Add: 10.66.248.021
SPARE
East Truss
S400 Rack 421
South Truss
S400 Rack 411
Cat 5e (Artnet)
214 Rackland
SPARE Univ: 31,33,35,x,x,x
VIA12 Gigabit SwitchIP Add: 10.66.202.011
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Node Plus (S400 Mode)
Add:222
Univ: 31,33,35,x,x,x
Node Plus (S400 Mode)
Add:221
Univ: 28,29,x,x,x,x
Cat 5e (Artnet)
VIA12 Gigabit SwitchIP Add: 10.66.248.211
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Node Plus (S400 Mode)
Add:224
Node Plus (S400 Mode)
Add:223
Cat 5e (Artnet)
SPARE Univ: 28,29,x,x,x,x,
SPARE
SPARESPARE
SPARE SPARE
208 Rackland
SPARE Univ: 30,31,32,x,x,x
VIA12 Gigabit SwitchIP Add: 10.66.202.012
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Node Plus (S400 Mode)
Add:232
Univ: 30,31,32,x,x,x
Node Plus (S400 Mode)
Add:231
Univ: 25,26,27,x,x,x
Cat 5e (Artnet)
VIA12 Gigabit SwitchIP Add: 10.66.248.212
Risk of electric shock.Disconnect power
before opening.Risque de decharge
electrique. Debrancherle pouvoir avant
d'ouvrier.90-260VAC
.75A 50/60 Hz
ATTENTION
48VDC PoE INPUT200W MAX
AC THRUMAX 10A
VIAMANAGED GIGABIT
POELINK/ACT
ETHERNET SWITCH
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Node Plus (S400 Mode)
Add:234
Node Plus (S400 Mode)
Add:233
Cat 5e (Artnet)
SPARE Univ: 25,26,27,x,x,x
SPARE
Cat 5e (UPLINK)
Cat 5e (UPLINK)
Cat 5e (UPLINK)
TO FIELD TO SUITES & 200 Level
TO CATWALK
CATWALK FIBER1200’ OptiCON Duo Fiber x 2
(4 x 600’ + 2 x Coupler)
FIELD FIBER950’ OptiCON Duo Fiber x 3
(3 x 600’ + 3 x 350’ + 3 x Coupler)
600’
Opt
iCO
N D
uo F
iber
x 2
(2 x
600
’ )
250’ OptiCON Duo Fiber x 2(2 x 250’ )
250’ OptiCON Duo Fiber x 2(2 x 250’ )
250’ OptiCON Duo Fiber x 2(2 x 250’ )
350’ OptiCON Duo Fiber x 2(2 x 350’ )
550’ Limo Fiber x 2(2 x 350’+ 2 x 200’ )
Univ: 47,48,53,x,x,x,98,99
Addr: 712
Univ: 98,99,x,x,x,x
Node Plus Add: 733
Univ: 98,99,x,x,x,x
Node Plus Add: 736
Cat 5e (Artnet)Cat 5e (Artnet)
SPARESPARE
SPARE
Univ: 49,50,51,53,x,x,98,99Univ: 60,61,62,63,42,43,44,45SPARE SPARE
SPARESPARE
Univ: 103,106,109,112,145,124,136Univ:103,106,109,112,145,124,136
Node Plus Add: 803
Univ: 98,99,x,x,x,x
Node Plus Add: 806
SPARE Univ: 98,99,x,x,x,x
Addr: 804Supernode (S400 Mode) 114/134
113/135110/111107/108104/105101/102115/139116/140116/141117/141
120/134121/135122/125125/126128/129131/132119/138119/142118/144117/147
Supernode (S400 Mode)Addr: 801
S400 ToolsIP Add:10.66.200.2
SUITES & 200 LEVEL FIBER1250’ OptiCON Duo Fiber x 2
2 x 1000’ + 2 x 250’+ 2 x Coupler)
PROGRAMING FIBER350’ Limo Fiber x 2
(2 x 350’)
1000’ OptiCon Duo Fiberx2 Active & Spare
Pete’s ProgramingPosition of Sugar
Supernode Add: 6
Cat 5e (v676)
Cat 5e (Artnet)
IP Add: 10.66.0.41
grandMA 3D IP Add: 192.168.0.3
Univ12/x12/x13/x13/x14/x14/x20/x21/xx/xx/x
Univ1/x1/x2/x2/x3/x3/x4/x4/xx/xx/x
Univ6/x6/x7/x8/xx/xx/xx/xx/xx/xx/x
S400 Rack 511Univ9/x9/x
10/x11/x11/x18/x19/xx/xx/xx/x
10-Port Switch
10-Port Switch
Cat 5e (Artnet)Cat 5e (Artnet)
SPARE
10-Port Switch
S400 Rack 311
Cat 5e (Artnet)
Univ15/x15/x16/x17/xx/xx/xx/xx/xx/xx/x
10-Port Switch
10-Port SwitchSPARE
10-Port Switch
10-Port Switch
SPARE
10-Port Switch
550’ Limo Fiber x 2(2 x 350’+ 2 x 200’ )
550’ Limo Fiber x 2(2 x 350’+ 2 x 200’ )
CISCO SG112 Gigabit SwitchIP Add: 192.168.101.2
Hippo 2: 192.168.0.32Artnet IP: 10.66.0.32
IP Add: 192.168.0.21NPU #4
IP Add: 192.168.0.22NPU #5
IP Add: 192.168.0.23
NPU #6
CISCO SG112 Gigabit SwitchIP Add: 192.168.101.1
Cat 5e
(MA/sAC
N N
et)
PathfinderIP Add: 192.168.0.42
PathfinderIP Add: 192.168.0.41
Cat 5e (MA/sACN Net)Cat 5e (MA/sACN Net)
PathfinderIP Add: 192.168.0.52
200’ Limo Fiberx8 Active & Spare
Univ: 127,130,133,145,146,
Addr: 802Supernode (S400 Mode)
Cat 5e(MA/sACN Net)
Addr: 805Supernode (S400 Mode)
Univ:127,130,133,145,146
Cat 5e(Artnet)
Cat 5e(MA/sACN Net)
Cat 5e(Artnet)
Cat 5e(MA/sACN Net)
Glow MotionIP Add: 192.168.0.53