Lighting Standards Manual A. Lamp Standards A1. General Quality Standards A2. Parts Diagrams A3. QC Lighting Standards B. Body Materials B1. Crystal B2. Glass B3. Acrylic B4. Polyresin B5. Metal B6. Ceramic B7. Mirrors C. Lamp Shades C1. General quality C2. General parts diagram C3. Visual sizing of shades C4. Measurements C5. Heat Ventilation C6. Shade Shapes C7. Lampshade materials C8. Lamp fitting types D. Bulbs and Sockets D1. Socket types D2. Base types D3. Bulb types E. Switches E1. Switch types F. Outlets and ports F1. Outlet and Port types

Upload: others

Post on 23-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

Lighting Standards Manual  

A. Lamp Standards 

A1. General Quality Standards 

A2. Parts Diagrams 

A3. QC Lighting Standards 

 

B. Body Materials  

B1. Crystal 

B2. Glass 

B3. Acrylic 

B4. Polyresin 

B5. Metal 

B6. Ceramic 

B7. Mirrors 

 

C. Lamp Shades  

C1. General quality  

C2. General parts diagram  

C3. Visual sizing of shades  

C4. Measurements  

C5. Heat Ventilation  

C6. Shade Shapes  

C7. Lampshade materials  

C8. Lamp fitting types  

 

D. Bulbs and Sockets  

D1. Socket types  

D2. Base types  

D3. Bulb types 

 

E. Switches  

E1. Switch types  

 

F. Outlets and ports  

F1. Outlet and Port types  

   

Page 2: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

A. Lamp Standards 

A1. General quality standards: 

‐UL Approval & Label: Provide UL approved and labeled products for U.S. or equivalent governing certification.  

‐Codes: Comply with governing electrical codes for lighting.  

‐Lamps: To maintain guest satisfaction, comply with color quality performance, instant on, silent, and flicker free 

operation equivalent to incandescent lamps.  

‐Color: 2700 degrees Kelvin minimum, 85 CRI . Per individual specification. 

‐Metal Components: Seal with clear powder coating to withstand 1000 hour salt spray test.  

‐Cord: Provide electric cord of sufficient length to reach electrical outlet.  

‐Bases: Provide table lamps and floor lamps with weighted bases to prevent tipping. Include power outlet in table lamp 

base.  

‐Desk lamp cords to have sufficient insulating construction to prevent interference and have a minimum wire thickness 

of 18 gauge  

A2. Parts Diagrams:  

                       

Page 3: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

A3. QC Lighting Standards: 

 

Category A: Raw materials and finished components 

‐Tubing, plates, ballast, outlets, usb, wires pass QC. 

‐Dimension of cut metal components must match approved shop drawings. 

‐Metal work welding and polishing of good quality, no rough spots. 

‐Salt test at plating factory passed (48 hour 1 year, 72 hour 2 year)  

‐Checking for plating quality, welding, polishing. 

 

Category B: Finishes  

*REQUIRE photos of master sample next to pre production sample approved by designer by email. 

‐Metal finish matches shop and master sample. 

‐Lamp shade material and color match shop and master sample. 

‐Confirm dimensions of the shade/quality of the shade. 

‐Glass or acrylic material matches shop and master sample 

‐Color of paint matches the voice of color sample, and shop drawing 

‐Wood or stone finish matches the shop and sample 

 

Category C: Assembly and UL testing of mass production 

‐Confirmation of all components (metal, electrical, shade, hardware) 

‐Neg positive test 

‐Temperature test 

‐High voltage test 

‐Wiring flow test‐does it illuminate with specified bulb 

‐LED aging test 48 hrs completed 

‐Tilt test 

 

Category D: Packaging and Qty 

‐Final clean and application of UL sticker with approved number. 

‐Packaging materials and methods follow Standards   

Page 4: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

B. Body Materials  

B1. Crystal (leaded glass) 

‐Crystal is a type of glass. Normal glass is a mixture of silicate (sand), lime, and soda. Crystal glass differs from normal 

glass as it contains high levels of lead oxide (leading to its more correct name: leaded glass).  

‐The most important aspect of crystal glass (especially in the lighting industry) is the refraction index and clarity. Crystal, 

unlike glass, will fragment light beams into a rainbow of colors sparking through the facets. Greater workability also 

allows for crystal glass to be formed into thinner and more delicate shapes. 

      

B2. Glass 

‐Regular soda‐lime glass has several attributes that make it a good choice for many applications. The harder, but not 

denser, composition of glass makes it less likely to scratch.  

‐When utilized for forms that are rounded and not faceted (such as rounded body lamp bases ), regular glass is more 

than suitable.  

‐Blown glass is best used in pendants, or areas that are not in constant contact with users. For bedside lamps, however, 

in high use areas, the more durable choice is Acrylic.  

‐Glass can be frosted, or clear. 

‐Frosted glass will make the shade appear white, and will diffuse the light. The light will still be brighter near the source. 

This example shows a dual shade. The outside is clear, the inside shade is frosted. 

      

Page 5: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

B3. Acrylic 

‐Acrylic shades or bases offer a most cost effective, lighter weight, and less breakable solution for a glass look base or 

shade. 

‐Acrylic can be clear, frosted, or colored to match any color, externally or internally.  

‐The finish on the acrylic can be matte or gloss.  

‐Shades made of acrylic are also good for sconces in wet or high traffic areas where linen would not be suitable.  

‐Acrylic sheets are readily available and when formed into shapes do not require a mold.  

‐Acrylic is a common material used for diffusers as well 

        

B4. Polyresin 

‐Polyresin is not as clear as acrylic, and not as hard as acrylic, so It should be used in situations where solid colors are 

needed for a molded base.   

‐It can be painted or colored to imitate stone, or metal , or textured surfaces like wood or ceramic.  

‐Each shape requires a mold to be created.  

        

 

 

   

Page 6: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

B5. Metal 

‐Metal lamp bases can be round or square tube or sheet metal, welded into a variety of designs. 

‐Metal can be powder coated or plated.  

‐See standard metal finishes for options. 

      

‐ All stainless should be of a gauge appropriate to piece and have no objectionable weld joints. ‐Polishing must be done to a satisfactory finish, to allow for proper plating adhesion. ‐Plated and powder coated components must pass the salt test.  ‐ Metal finishes must have clear enamel matte coating, clear rust inhibitor, baked enamel, or powder coated finish for humidity protection to prevent rust and corrosion.  Manufacturer to ensure materials are non‐corrosive and suitable for use in high humidity and salt air locations as required.  Electroplating‐ Electroplating is a process that uses electric current to reduce dissolved metal cations so that they form a 

coherent metal coating on an electrode. Electroplating changes the actual surface properties of the metal.  

 

         

Powdercoating‐ Powder coating is a type of coating that is applied as a free‐flowing, dry powder. The coating is applied 

electrostatically and is then cured under heat to allow it to flow and form a "skin". It creates a hard finish that is tougher 

than conventional paint. Powder coating can be non metallic, or contain metallic particles.  

 

 

 

Page 7: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

 

Standard metal codes are specified using the following designations: 

1. Each “color” is represented by a Letter. 

2. Each “finish” is represented by a Letter. (P‐Polished, B‐Brushed, X‐Powdercoated) 

 

 

Page 8: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

B6. Ceramic 

‐Ceramic is a heavy, breakable material, made from clay 

‐Glazes can create unique patterns only available with clay 

‐Voids can be removed from the clay to create a lattice effect 

‐Clay can be sculpted into a variety of artistic forms, using a potter’s wheel or sculpting tools 

          

   

Page 9: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

C.Lamp Shades 

 C1. General quality: 

‐Rust preventing coating on frame 

‐Well seamed trimming on top ring and bottom ring 

‐Color coated ribs to match shade, vertical piping as specified 

‐Tight knit weave fabric with complementary Hardback lining 

‐High craftsmanship ensuring a long‐lasting shade 

‐Adequate spacing between bulb and shade for wattage as specified 

 

C2. General parts diagram: 

  

 

 

C3. Visual sizing of shades: 

Typically, the shade size should be 1/3 of the overall lamp, 

leaving 2/3 of the height for the base, and large enough to 

cover the bulb and socket. The Typical width of the shade is 2 

times the width of the base. However, an over or undersized 

shade can create artistic effect.  

 

 

 

C4. Measurements: 

To measure a lampshade list the: 

Top Dia x Bottom Dia X Height or Slant 

 

Measure the height of the lampshade through the 

center. If there is a drop for the washer, it is measured 

from the top of the shade to the top of the washer. 

 

Note also the fitting type. (UNO or Spider with harp) 

   

Page 10: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

C5. Heat Ventilation: 

The crucial information you need to obtain in order to determine if the shade is large enough for the bulb strength you 

are going to use is the “critical radius” or measurement taken from the middle of the light bulb to the inside edge of the 

lamp shade (see diagram). For example, for a 60‐watt bulb, there must be at least 2‐7/8″ of space between the filament 

and inside edge of the lamp shade in order to operate safely. 

 

The Underwriters Laboratories rating (UL rating) listed on the socket will indicate the highest wattage bulb allowed for 

that shade and this rating should be strictly adhered to. Through extensive testing they have determined the following 

safe critical radius ratios: 

 

   

Page 11: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

C6. Shade Shapes: 

 

  

 

  

Shades are available in Any one of our 

standard shade fabrics. 

 Some styles available in acrylic, or glass 

(frosted or clear). 

Custom shapes and sizes available. 

Page 12: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

C7. Lampshade Fabrics: 

 

 

Page 13: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

 

C8. Lamp fitting types:  

 

A Fitter is the component that a lamp shade uses to attach to the base. The two that are used commonly in the 

hospitality industry are: 

 

Slip UNO Fiting/Drop UNO  

The spider holds a metal ring, which sits on the socket, and is 

held in place by the lightbulb. This style requires no harp, and 

no finial.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spider with Harp 

A spider fitter has a small metal ring in the center on the top of the 

shade. This sits on top of the harp, which is a metal component, that fits 

into the harp saddle, which is connected to the socket. You secure the 

components by screwing on a decorative metal top piece, called a finial. 

The harp is usually 1‐2” shorter than the shade height 

 

   

Page 14: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

D.Bulbs and Sockets 

 D1. Socket types: 

                                 

 

Socket standard Medium base CFL                       Socket‐GU 24 bulb         Circulene Fluorescent bulb and ballast 

 

 

                Socket back to back twin                             Socket S‐body twin 

 

 

D2. Base types:  

  

Page 15: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

D3. Bulb types:  

 

 

    

Page 16: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

E.Switches 

 E1. Switch types: 

                                                                    On/Off Rocker Single‐ ADA                       On/Off Rocker Double‐ ADA                  Two Single Rockers 

 

           Push through‐ ADA                                      Push button at base‐ ADA   

 

 Rotary Switch‐ Non ADA                                    Dimmer Switch‐ Non ADA                         

 

   

Page 17: Lighting Standards Manual · To measure a lampshade list the: Top Dia x Bottom Dia X Height or Slant Measure the height of the lampshade through the center. If there is a drop for

F.Outlets and Ports 

 F1. Outlet/Port types: 

 

 Single convenience outlet      (Can use more than 1 per lamp)   

 

 

                               USB Port                                                                                                  RJ45 Port