lightspeed rocket hardware installation guide

16
1800 19th Street / Bakersfield, CA 93301 / Tel: 661.716.7600 / Toll Free: 877.447.6244 / www.lightspeedsystems.com Lightspeed Rocket Hardware Installation Guide

Upload: others

Post on 15-Mar-2022

11 views

Category:

Documents


0 download

TRANSCRIPT

1800 19th Street / Bakersfield, CA 93301 / Tel: 661.716.7600 / Toll Free: 877.447.6244 / www.lightspeedsystems.com

Lightspeed RocketHardware Installation Guide

Lightspeed Rocket Hardware Installation Guide 2

Table of Contents

Section 1 Safety Notice and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Section 2 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Section 3 Electrical and General Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Section 4 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Section 5 Unpacking and Installing the Appliance in the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Section 6A Lightspeed Rocket Email Management - 1Gb Rear Panel Connections . . . . . . . . . . . . . . . . . . . 7

Section 6B Lightspeed Web Filter Policy Parent Rear Panel Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Section 6C Lightspeed Rocket Web Filter - 1Gb Rear Panel Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Section 6D Lightspeed Rocket Web Filter - 1Gb Fiber Rear Panel Connections . . . . . . . . . . . . . . . . . . . . . . 10

Section 6E Lightspeed Rocket Web Filter and Traffic Bridge - 10Gb Fiber Rear Panel Connections . . . . . . 11

Section 6F Lightspeed Rocket Web Filter - Dual Bridge 1Gb Fiber Rear Panel Connections . . . . . . . . . . . 12

Section 7 Front Panel Operation and End User License Agreement (EULA) . . . . . . . . . . . . . . . . . . . . . . . 13

Section 8 Bezel Installation on the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Lightspeed Rocket Hardware Installation Guide 3

1. Safety Notice and Warnings

2. Ratings

FCC NoticeThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference received, including interference that may cause undesired operation.

No Telecommunications Network Voltage (TNV)-connected PCBs shall be installed.

CAN ICES-3 (A)/NMB-3(A)

CE Mark WarningThis is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

VCCI WarningThis is a product of VCCI Class A Compliance.

Environmental WarningPerchlorate Material - special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate.

This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product/part includes a battery that contains perchlorate material.

AC input voltage: 100 - 240 VAC (auto-range)

Hz: 50/60

A: 100 - 127V ~/4A Max200 - 240V ~/2A Max

Lightspeed Rocket Hardware Installation Guide 4

CAUTIONThis appliance is intended for installation in restricted areas only. Initial setup and maintenance should beperformed by qualified personnel.

CAUTIONPower down the appliance following the operating system’s proper power down procedure using the front panel power button. Unplug the AC power cord(s) before servicing.

CAUTIONTo avoid electrical shock, check the power cords as follows:• This product is to be installed in Restricted Access Location only.• Use the exact type of power cords required.• Use power cord(s) that came with safety certifications. • Power cord(s) must comply with AC voltage requirements in your region.• The power cord plug cap must have an electrical current rating that is at least 125% of the electrical

current rating of this product. • The power cord plug cap that plugs into the AC receptacle on the power supply must be an IEC 320,

sheet C13, type female connector.• Plug the power cord(s) into a socket that is properly grounded before turning on the power.

CAUTIONRequired operating conditions for the appliance are:• Temperature: 10 to 35oC. • Humidity, non-condensing: 8 to 90%.

CAUTIONCLASS 1 LASER PRODUCTAPPAREIL À LASER DE CLASSE 1.

CAUTIONRisk of explosion if the battery is installed upside down or is replaced by an incorrect type. Dispose of used batteries according to the instructions.

DISPOSING OF BATTERY BACKUP UNITS - IF APPLICABLEWARNINGIf the BBU is damaged in any way, toxic chemicals may be released.The material in the battery pack contains heavy metals that can contaminate the environment. Federal,state, and local regulations prohibit the disposal of rechargeable batteries in public landfills. Be sure to recycle the old battery packs properly. Comply with all applicable battery disposal and hazardous materialhandling laws and regulations in the country or other jurisdiction where you are using the BBU.

3. Electrical and General Safety Guidelines

Lightspeed Rocket Hardware Installation Guide 5

WARNINGThere is danger of an explosion if the battery is incorrectly replaced. Replace it only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

WARNINGDisconnect the power supply at the circuit breaker before accessing any components. Turning off the system power supply switch does not reduce the risk of electrical shock from the power supply terminalblock.

CAUTION• To prevent the unit from overheating, never install the appliance in an enclosed area that is not properly

ventilated or cooled. For proper airflow, keep the front and back sides of the appliance clear of obstructions and away from the exhaust of other equipment.

• Be aware of the locations of the power switches on the chassis and in the room, so you can disconnect the power supply if an accident occurs.

• Take extra precautionary measures when working with high voltage components. Do not work alone. • Before removing or installing main system components, be sure to disconnect the power first. Turn the

system off before you disconnect the power supply.• Use only one hand when working with powered-on electrical equipment to avoid possible

electrical shock. • Use rubber mats specifically designed as electrical insulators when working with computer systems.• The power supply or power cord must include a grounding plug and must be plugged into grounded

outlets.

CAUTIONElectric Static Discharge (ESD) can damage electronic components. To prevent damage to your systemboard, it is important to handle it very carefully. The following measures can prevent ESD damage to critical components.

• Use a grounded wrist strap designed to prevent static discharge.• Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use.• Touch a grounded metal object before removing the board from the antistatic bag.• Do not let components or PCBs come into contact with your clothing, which may retain a charge even if

you are wearing a wrist strap.• Handle a board by its edges only; do not touch its components, peripheral chips, memory modules

or contacts.• When handling chips or modules, avoid touching their pins.• Put the motherboard and peripherals back into their antistatic bags when not in use.• For grounding purposes, make sure your computer chassis provides excellent conductivity between the

power supply, the case, the mounting fasteners and the motherboard.

3. Electrical and General Safety Guidelines (continued)

Lightspeed Rocket Hardware Installation Guide 6

Setup location, rack and appliance precautions• Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating

ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.Always keep the rack’s front door and all panels and components on the appliances closed when not servicing to maintain proper cooling.

• Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Leave enough clearance, approximately 25 inches in the front, and 30 inches in the back of the rack to enable you to access appliance components and allow for sufficient air flow.

• Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. ALL RACKS MUST BE MOUNTED SECURELY. Ensure that all leveling jacks or stabilizers are properly attachedto the rack. If installing multiple appliances in a rack, make sure the overall loading for each branch circuit does not exceed the rated capacity. Do not slide more than one appliance out from the rack at a time. Extending more than one appliance at a time may result in the rack becoming unstable. Install your appliance in the lower part of the rack because of its weight and also for ease in accessing appliance components.

• Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

• Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).Install near appropriate AC outlets, and Ethernet hubs or individual jacks. Be sure to install an AC Power Disconnect for the entire rack assembly. The Power Disconnect must be clearly marked. Ground the rack assembly properly to avoid electrical shock.

4. Site Preparation

Before you begin:Verify that the ship kit includes both power cords and the host rail kit you will beusing to install the appliance in your rack. The rail kit contains the hardware, rails andinstallation instructions for the rails specific to your appliance.

Installing the Appliance in the Rack:• Follow the rail installation instructions included in the rail kit to install the appliance in your rack.

• After the appliance is installed in the rack, proceed to Section 6 on page 7 for rear panel connections.

5. Unpacking and Installing the Appliance in the Rack

NOTE: Use the hardware supplied with your specificrack if different from the hardware supplied in this kit.

Lightspeed Rocket Hardware Installation Guide 7

ID POST ID

Power Cords

AC Power Inlets

Video Port

Power Good LEDs

USB Ports

Network Interface Connectors

EthernetCable Local

AreaNetwork

2

ManagementPort4

1

AuxilliaryPort

dsPower Cor

Power Good LEDs

PorPortageManagemen44

PortPortxilliAuxilliary

Management

Network Interface Connectors

USB Ports

Network Interface Connectors

ideo PortV

InletsAC Power

ID

CableEther1Cable

netEther

NetworkeaAr

Local

22

6A. Lightspeed Rocket Email Management - 1Gb Rear Panel Connections

CAUTIONSlide rail/mounted equipment is not to be used as a shelf or a work space.

Step 1 Connect one end of the yellow Ethernet cable into the Ethernet port labeled MANAGEMENT.

Step 2 Connect the other end of the yellow Ethernet cable into an available switch port on your Local Area Network. This port will require Internet access.

Step 3 Please review the latest Lightspeed Systems Rocket Email Management Product Manual on the Lightspeed Systems Community Site at (http://community.lightspeedsystems.com/product-information/documentation/email-management/).

Step 4 Connect the power cords.

Step 5 Proceed to Front Panel Operation on page 13.

NOTE: The server offers redundant, hot-swap capability. The connectionsto AC mains should be made in a manner appropriate to local code andconsistent with customer power distribution with or without redundantsources.

CAUTIONThe power supply is hot-swappable only when you have a server with redundant power supplies installed. If you only have one power supply installed, before removing or replacing the power supply, you must firsttake the server out of service, turn off all peripheral devices connected tothe server, turn off the server by pressing the power button, and unplug theAC power cord from the server or wall outlet.

Power Supply Condition

Output ON and OK

No AC power to both power supplies

AC present / Only 5VSB on (PS off)

AC cord unplugged or AC power lost; with a secondpower supply in parallel still with AC input power

Power supply warning events where the power supply continues to operate; high temp, high power,high current, slow fan

Power supply critical event causing a shutdown; failure, Over Current Protection, Over VoltageProtection, fan fail

LED State

GREEN

OFF

1Hz BlinkingGREEN

AMBER

1Hz BlinkingAMBER

AMBER

Power Supply Status LEDThere is a single bi-color Power Good LED on each power supplymodule to indicate power supply status. The LED operation isdefined in the following table.

In normal operation the Power Good LED on Power Supply Module 1and Module 2 will be SOLID GREEN. If the power is down, both LEDswill BLINK GREEN.

Lightspeed Rocket Hardware Installation Guide 8

ID POST ID

Power Cords

AC Power Inlets

Video Port

Power Good LEDs

USB Ports

Network Interface Connectors

EthernetCable Local

AreaNetwork

2

ManagementPort4

1

AuxilliaryPort

dsPower Cor

Power Good LEDs

PorPortageManagemen44

PortPortxilliAuxilliary

Management

Network Interface Connectors

USB Ports

Network Interface Connectors

ideo PortV

InletsAC Power

ID

CableEther1Cable

netEther

NetworkeaAr

Local

22

6B. Lightspeed Web Filter Policy Parent Rear Panel Connections

CAUTIONSlide rail/mounted equipment is not to be used as a shelf or a work space.

Step 1 Connect one end of the yellow Ethernet cable into the Ethernet port labeled MANAGEMENT.

Step 2 Connect the other end of the yellow Ethernet cable into an available switch port on your Local Area Network. This port will require Internet access.

Step 3 Please review the latest Lightspeed Systems Rocket Web Filter Product Manual on the Lightspeed Systems Community Site at (http://community.lightspeedsystems.com/product-information/documentation/web-filter/).

Step 4 Connect the power cords.

Step 5 Proceed to Front Panel Operation on page 13.

NOTE: The server offers redundant, hot-swap capability. The connectionsto AC mains should be made in a manner appropriate to local code andconsistent with customer power distribution with or without redundantsources.

CAUTIONThe power supply is hot-swappable only when you have a server with redundant power supplies installed. If you only have one power supply installed, before removing or replacing the power supply, you must firsttake the server out of service, turn off all peripheral devices connected tothe server, turn off the server by pressing the power button, and unplug theAC power cord from the server or wall outlet.

Power Supply Condition

Output ON and OK

No AC power to both power supplies

AC present / Only 5VSB on (PS off)

AC cord unplugged or AC power lost; with a secondpower supply in parallel still with AC input power

Power supply warning events where the power supply continues to operate; high temp, high power,high current, slow fan

Power supply critical event causing a shutdown; failure, Over Current Protection, Over VoltageProtection, fan fail

LED State

GREEN

OFF

1Hz BlinkingGREEN

AMBER

1Hz BlinkingAMBER

AMBER

Power Supply Status LEDThere is a single bi-color Power Good LED on each power supplymodule to indicate power supply status. The LED operation isdefined in the following table.

In normal operation the Power Good LED on Power Supply Module 1and Module 2 will be SOLID GREEN. If the power is down, both LEDswill BLINK GREEN.

Lightspeed Rocket Hardware Installation Guide 9

6C. Lightspeed Rocket Web Filter - 1Gb Rear Panel Connections

ID POST ID

AC Power Inlets

Video Port

EthernetCable Local

AreaNetwork

2

Power Cords

Power Good LEDs

USB Ports

Network Interface Connectors

ManagementPort4

AuxilliaryPort

1

Internal

External

dsPower Corrd

Power Good LEDs

PorPortageManagemen44

PortPortxilliAuxilliary

ManagementernalInt

Exter

Network Interface Connectors

USB Ports

nal

ternalxter

Network Interface Connectors

ideo PortV

InletsAC Power

ID

CableEther1Cable

netEther

NetworkeaAr

Local

22

CAUTIONSlide rail/mounted equipment is not to be used as a shelf or a work space.

Power Supply Condition

Output ON and OK

No AC power to both power supplies

AC present / Only 5VSB on (PS off)

AC cord unplugged or AC power lost; with a secondpower supply in parallel still with AC input power

Power supply warning events where the power supply continues to operate; high temp, high power,high current, slow fan

Power supply critical event causing a shutdown; failure, Over Current Protection, Over VoltageProtection, fan fail

LED State

GREEN

OFF

1Hz BlinkingGREEN

AMBER

1Hz BlinkingAMBER

AMBER

Power Supply Status LEDThere is a single bi-color Power Good LED on each power supplymodule to indicate power supply status. The LED operation isdefined in the following table.

In normal operation the Power Good LED on Power Supply Module 1and Module 2 will be SOLID GREEN. If the power is down, both LEDswill BLINK GREEN.

NOTE: The server offers redundant, hot-swap capability. The connectionsto AC mains should be made in a manner appropriate to local code andconsistent with customer power distribution with or without redundantsources.

CAUTIONThe power supply is hot-swappable only when you have a server with redundant power supplies installed. If you only have one power supply installed, before removing or replacing the power supply, you must firsttake the server out of service, turn off all peripheral devices connected tothe server, turn off the server by pressing the power button, and unplug theAC power cord from the server or wall outlet.

Step 1 Connect one end of the yellow Ethernet cable into the Ethernet port labeled MANAGEMENT.

Step 2 Connect the other end of the yellow Ethernet cable into an available switch port on your Local Area Network. This port will require Internet access.

Step 3 Please review the latest Lightspeed Systems Rocket Web Filter Product Manual on the Lightspeed Systems Community Site at (http://community.lightspeedsystems.com/product-information/documentation/web-filter/).

Step 4 Connect the power cords.

Step 5 Proceed to Front Panel Operation on page 13.

Lightspeed Rocket Hardware Installation Guide 10

6D. Lightspeed Rocket Web Filter - 1Gb Fiber Rear Panel Connections

ID POST ID

AC Power Inlets

Video Port

EthernetCable Local

AreaNetwork

2

1

Power Cords

Power Good LEDs

USB Ports

Network Interface Connectors

ManagementPort4

AuxilliaryPort

Internal

External

dsPower Corrd

Power Good LEDs

PorPortageManagemen44

PortPortxilliAuxilliary

ManagementernalInt

Exter

Network Interface Connectors

USB Ports

ternalExter

Network Interface Connectors

ideo PortV

InletsAC Power

ID

CableEther1Cable

netEther

NetworkeaAr

Local

22

CAUTIONSlide rail/mounted equipment is not to be used as a shelf or a work space.

Power Supply Condition

Output ON and OK

No AC power to both power supplies

AC present / Only 5VSB on (PS off)

AC cord unplugged or AC power lost; with a secondpower supply in parallel still with AC input power

Power supply warning events where the power supply continues to operate; high temp, high power,high current, slow fan

Power supply critical event causing a shutdown; failure, Over Current Protection, Over VoltageProtection, fan fail

LED State

GREEN

OFF

1Hz BlinkingGREEN

AMBER

1Hz BlinkingAMBER

AMBER

Power Supply Status LEDThere is a single bi-color Power Good LED on each power supplymodule to indicate power supply status. The LED operation isdefined in the following table.

In normal operation the Power Good LED on Power Supply Module 1and Module 2 will be SOLID GREEN. If the power is down, both LEDswill BLINK GREEN.

NOTE: The server offers redundant, hot-swap capability. The connectionsto AC mains should be made in a manner appropriate to local code andconsistent with customer power distribution with or without redundantsources.

CAUTIONThe power supply is hot-swappable only when you have a server with redundant power supplies installed. If you only have one power supply installed, before removing or replacing the power supply, you must firsttake the server out of service, turn off all peripheral devices connected tothe server, turn off the server by pressing the power button, and unplug theAC power cord from the server or wall outlet.

Step 1 Connect one end of the yellow Ethernet cable into the Ethernet port labeled MANAGEMENT.

Step 2 Connect the other end of the yellow Ethernet cable into an available switch port on your Local Area Network. This port will require Internet access.

Step 3 Please review the latest Lightspeed Systems Rocket Web Filter Product Manual on the Lightspeed Systems Community Site at (http://community.lightspeedsystems.com/product-information/documentation/web-filter/).

Step 4 Connect the power cords.

Step 5 Proceed to Front Panel Operation on page 13.

Lightspeed Rocket Hardware Installation Guide 11

ID POST ID

AC Power Inlets

Video Port

EthernetCable Local

AreaNetwork

2

1

Power Cords

Power Good LEDs

USB Ports

Network Interface Connectors

ManagementPort4

AuxilliaryPort

Internal

External

dsPower Corrd

Power Good LEDs

PorPortageManagement44

PortPortxilliAuxilliary

ManagementnnalerInt

Exter

Network Interface Connectors

USB Ports

ternalxter

Network Interface Connectors

ideo PortV

InletsAC Power

ID

CableEther1Cable

netEther

NetworkeaAr

Local

22

6E. Lightspeed Rocket Web Filter and Traffic Bridge - 10Gb Fiber Rear Panel Connections

CAUTIONSlide rail/mounted equipment is not to be used as a shelf or a work space.

NOTE: The server offers redundant, hot-swap capability. The connectionsto AC mains should be made in a manner appropriate to local code andconsistent with customer power distribution with or without redundantsources.

CAUTIONThe power supply is hot-swappable only when you have a server with redundant power supplies installed. If you only have one power supply installed, before removing or replacing the power supply, you must firsttake the server out of service, turn off all peripheral devices connected tothe server, turn off the server by pressing the power button, and unplug theAC power cord from the server or wall outlet.

Power Supply Condition

Output ON and OK

No AC power to both power supplies

AC present / Only 5VSB on (PS off)

AC cord unplugged or AC power lost; with a secondpower supply in parallel still with AC input power

Power supply warning events where the power supply continues to operate; high temp, high power,high current, slow fan

Power supply critical event causing a shutdown; failure, Over Current Protection, Over VoltageProtection, fan fail

LED State

GREEN

OFF

1Hz BlinkingGREEN

AMBER

1Hz BlinkingAMBER

AMBER

Power Supply Status LEDThere is a single bi-color Power Good LED on each power supplymodule to indicate power supply status. The LED operation isdefined in the following table.

Step 1 Connect one end of the yellow Ethernet cable into the Ethernet port labeled MANAGEMENT.

Step 2 Connect the other end of the yellow Ethernet cable into an available switch port on your Local Area Network. This port will require Internet access.

Step 3 Please review the latest Lightspeed Systems Rocket Web Filter Product Manual on the Lightspeed Systems Community Site at (http://community.lightspeedsystems.com/product-information/documentation/web-filter/).

Step 4 Connect the power cords.

Step 5 Proceed to Front Panel Operation on page 13.

In normal operation the Power Good LED on Power Supply Module 1and Module 2 will be SOLID GREEN. If the power is down, both LEDswill BLINK GREEN.

Lightspeed Rocket Hardware Installation Guide 12

6F. Lightspeed Rocket Web Filter - Dual Bridge 1Gb Rear Panel Connections

ID POST ID

AC Power Inlets

Video Port

Power Cords

Power Good LEDs

USB Ports

Network InterfaceConnectors

ManagementPort4

AuxilliaryPort

EthernetCable Local

AreaNetwork

2

1

Internal 1

External 1

Internal 0

External 0

dsPower Cor

Power Good LEDs

PorPortageManagemen44

PortPortxilliAuxilliary

Management

nal 1erInte ConnectorsNetwork Interface

USB Ports

naal 1

nnal 1erExte

naal 0erInte

nnal 0erExte

ideo PortV

InletsAC Power

ID

CableEther1Cable

netEther

NetworkeaAr

Local

22

NOTE: The server offers redundant, hot-swap capability. The connectionsto AC mains should be made in a manner appropriate to local code andconsistent with customer power distribution with or without redundantsources.

CAUTIONThe power supply is hot-swappable only when you have a server with redundant power supplies installed. If you only have one power supply installed, before removing or replacing the power supply, you must firsttake the server out of service, turn off all peripheral devices connected tothe server, turn off the server by pressing the power button, and unplug theAC power cord from the server or wall outlet.

Power Supply Condition

Output ON and OK

No AC power to both power supplies

AC present / Only 5VSB on (PS off)

AC cord unplugged or AC power lost; with a secondpower supply in parallel still with AC input power

Power supply warning events where the power supply continues to operate; high temp, high power,high current, slow fan

Power supply critical event causing a shutdown; failure, Over Current Protection, Over VoltageProtection, fan fail

LED State

GREEN

OFF

1Hz BlinkingGREEN

AMBER

1Hz BlinkingAMBER

AMBER

Power Supply Status LEDThere is a single bi-color Power Good LED on each power supplymodule to indicate power supply status. The LED operation isdefined in the following table.

Step 1 Connect one end of the yellow Ethernet cable into the Ethernet port labeled MANAGEMENT.

Step 2 Connect the other end of the yellow Ethernet cable into an available switch port on your Local Area Network. This port will require Internet access.

Step 3 Please review the latest Lightspeed Systems Rocket Web Filter Product Manual on the Lightspeed Systems Community Site at (http://community.lightspeedsystems.com/product-information/documentation/web-filter/).

Step 4 Connect the power cords.

Step 5 Proceed to Front Panel Operation on page 13.

In normal operation the Power Good LED on Power Supply Module 1and Module 2 will be SOLID GREEN. If the power is down, both LEDswill BLINK GREEN.

CAUTIONSlide rail/mounted equipment is not to be used as a shelf or a work space.

Lightspeed Rocket Hardware Installation Guide 13

ID1

2

3

4

See Detail Illustration and Chart for Front Panel Information

USB PortsVideo Port

for FrSee Detail Illustration and Chart

ideo PortVUSB Ports

mation ont Panel Inforfor FrSee Detail Illustration and Chart

System Status LED

A B C D E F G

H I

A B C D

H IStatus LED

System

E F G

A System ID Button with integrated LED

B NMI Button (recessed, tool required for use)

C NIC 2 Activity LED

D NIC 4 Activity LED

E System Cold Reset Button

F Hard Drive Activity LED

G Power Button with integrated LED

H NIC 1 Activity LED

I NIC 3 Activity LED

System Status LEDThere is a bi-color (Green/Amber) LED on the Front Panel (shown onthe left). The LED operation is defined in the following table.

Criticality

Not ready

OK

Degraded - system is operating in a degraded state although still functional,OR system is operating in a redundant state but with animpending failure warning

Non-critical - system isoperating in a degradedstate with an impendingfailure warning, although still functioning

Critical, non-recoverable -system is halted

LED Color

OFF

GREEN

GREEN

AMBER

AMBER

System State

System is not operating

Solid - On

~1 Hz blinking

~1 Hz blinking

Solid - On

By powering on the appliance you agree to all terms and conditions included in the End User License Agreement (EULA) located at http://www.lightspeedsystems.com/eula/

Power on the appliance

n Press the power button located on the far right on the front side of the appliance.

7. Front Panel Operation

Lightspeed Rocket Hardware Installation Guide 14

ID1

2

3

4

21

Right FixedBezel Tab{ {Left Flexible

Bezel Tab

2

abBezel TTaLeft Flexible{

1

{ abBezel TTaRight Fixed

Step 1 Align the bezel with the front of the appliance. Insert the bezel tab on the right side of the bezel into the handle on the right side of the appliance.

Step 2 Swing the left side of the bezel in toward the appliance. Press in on the bezel to engage the bezel tab on the left side of the bezel into the handle on the left side of the appliance.

8. Bezel Installation on the Appliance

Lightspeed Rocket Hardware Installation Guide 15

This page intentionally left blank

Copyright ©2014-2015 Lightspeed Systems, Inc. All rights reserved.

Lightspeed Systems

1800 19th StreetBakersfield, CA 93301

Corporate PhoneTel: 661.716.7600Fax: 661.716.8600Toll Free: 877.447.6244Support: 800.444.9267

www.lightspeedsystems.com

Lightspeed Systems Europe:

Jubilee HouseThe Drive, Brentwood Essex CM13 3FR; Reg No: 05336060 England and Wales

Tel: +44 (0) 1277 240 630Fax: +44 (0) 1277 240 631