lims conditional assessment presentation; 4-9-14

24
LAUREL INTERMEDIATE / MIDDLE SCHOOL CONDITIONAL ASSESSMENT PRESENTED BY: JIM BAKER, P.E. MACINTOSH ENGINEERING APRIL 9, 2014

Upload: laurelschooldistrict

Post on 21-May-2015

156 views

Category:

Education


2 download

TRANSCRIPT

Page 1: LIMS Conditional Assessment Presentation; 4-9-14

LAUREL INTERMEDIATE / MIDDLE SCHOOL

CONDITIONAL ASSESSMENT

PRESENTED BY: JIM BAKER, P.E.

MACINTOSH ENGINEERING

APRIL 9, 2014

Page 2: LIMS Conditional Assessment Presentation; 4-9-14

CONDITIONAL ASSESSMENT (1921 BUILDING ASSESSMENT)

•ROOF & FLOOR CONSTRUCTION

•ROOF CONSTRUCTION

•1ST & 2ND FLOOR FRAMING CONSTRUCTION

•INTERIOR & EXTERIOR BRICK WALLS

•INTERIOR BEARING WALLS

•EXTERIOR BEARING WALLS

•EXISTING STEEL LINTELS SUPPORTING BEARING WALLS

•EXISTING CONCRETE KNEEWALL

•ARCHITECTURAL FEATURES

•LIMESTONE COPING / ARCHITECTURAL FEATURES

•MISCELLANEOUS ITEMS

•ITEMS REQUIRING REMEDIATION

Page 3: LIMS Conditional Assessment Presentation; 4-9-14

1921 ORIGINAL STRUCTURE

OVERALL BUILDING LAYOUT PLAN

Page 4: LIMS Conditional Assessment Presentation; 4-9-14

ROOF & FLOOR CONSTRUCTION

EXISTING ROOF CONSTRUCTION

- SIGNS OF WATER INFILTRATION IN 2ND FLOOR CEILING

Page 5: LIMS Conditional Assessment Presentation; 4-9-14

ROOF & FLOOR CONSTRUCTION

EXISTING ROOF CONSTRUCTION

- ANTICIPATE ROOF REINFORCING FOR NEW MECHANICAL

UNITS & PLUMBING

Page 6: LIMS Conditional Assessment Presentation; 4-9-14

ROOF & FLOOR CONSTRUCTION

- ANTICIPATE NEW FLOOR OPENINGS

- REQUIRES REINFORCING OF EXISTING FLOOR FOR NEW

OPENINGS & FLOOR INFILL

- NEW MECHANICAL PIPING LOCATED IN

CORRIDORS

- WILL REQUIRE REINFORCING / STEEL PLUMBING SUPPORT

FRAME TO SUPPORT NEW PIPING

- CONCRETE REPAIR OF EXISTING FIRST FLOOR

- REPAIR OF EXISTING SPALLING CONCRETE SUPPORT

MEMBERS

- POTENTIAL REINFORCING OF EXISTING FLOOR

LOCATED UNDER CURRENT LIBRARY

- DEPENDENT ON FUTURE USAGE & EXISTING FRAMING

CAPACITY

1ST & 2ND FLOOR CONSTRUCTION

Page 7: LIMS Conditional Assessment Presentation; 4-9-14

INTERIOR & EXTERIOR BRICK WALLS

- EXISTING AREAS OF HORIZONTAL & STEP CRACKING

- ANTICIPATE NEW OPENINGS IN EXISTING WALLS - FOR ADA ACCESSIBILITY & MECHANICAL OPENINGS

INTERIOR BEARING WALLS

Page 8: LIMS Conditional Assessment Presentation; 4-9-14

INTERIOR BEARING WALLS

INTERIOR & EXTERIOR BRICK WALLS

EXISTING HORIZONTAL CRACKING CONDITION

Page 9: LIMS Conditional Assessment Presentation; 4-9-14

INTERIOR & EXTERIOR BRICK WALLS

EXTERIOR BRICK WALLS

- CRACKING AT EXTERIOR BRICK CHIMNEY LOCATION

Page 10: LIMS Conditional Assessment Presentation; 4-9-14

INTERIOR & EXTERIOR BRICK WALLS

EXTERIOR BRICK WALLS

- EVIDENCE OF WATER INFILTRATION ON WALLS &

WINDOWS

Page 11: LIMS Conditional Assessment Presentation; 4-9-14

INTERIOR & EXTERIOR BRICK WALLS

EXISTING STEEL LINTELS

- CORROSION OF EXISTING EXTERIOR STEEL LINTELS

Page 12: LIMS Conditional Assessment Presentation; 4-9-14

INTERIOR & EXTERIOR BRICK WALLS

EXISTING STEEL LINTELS

STEEL LINTEL CORROSION CONDITION

Page 13: LIMS Conditional Assessment Presentation; 4-9-14

INTERIOR & EXTERIOR BRICK WALLS

STEEL LINTEL CORROSION CONDITION

EXISTING STEEL LINTEL

Page 14: LIMS Conditional Assessment Presentation; 4-9-14

INTERIOR & EXTERIOR BRICK WALLS

EXISTING CONCRETE KNEEWALL

- VERITICAL & OPEN CRACKS IN CONCRETE KNEEWALL

Page 15: LIMS Conditional Assessment Presentation; 4-9-14

INTERIOR & EXTERIOR BRICK WALLS

VERTICAL CRACKS AT CONCRETE KNEEWALL

Page 16: LIMS Conditional Assessment Presentation; 4-9-14

ARCHITECTURAL FEATURES

LIMESTONE FEATURES

- REQUIRES EXTENSIVE STRUCTURAL ASSESSMENT TO

BE PERFORMED TO DETERMINE CONDITION

- VERIFY FASTNERS OF LIMESTONE SECTIONS TO

EXISTING SUBSTRATE

- PERFORM SOUNDING TEST TO DETERMINE CONDITION

Page 17: LIMS Conditional Assessment Presentation; 4-9-14

ARCHITECTURAL FEATURES

LIMESTONE FEATURES

- DETERIORATION OF LIMESTONE HEADER BLOCKS

ABOVE WINDOWS

Page 18: LIMS Conditional Assessment Presentation; 4-9-14

ARCHITECTURAL FEATURES

LIMESTONE FEATURES

- VERTICAL CRACKING IN LIMESTONE & DETERIORATED

JOINTS

Page 19: LIMS Conditional Assessment Presentation; 4-9-14

ARCHITECTURAL FEATURES

LIMESTONE FEATURES

- SPALLING AT LIMESTONE ARCHITECTURAL COLUMNS

Page 20: LIMS Conditional Assessment Presentation; 4-9-14

ARCHITECTURAL FEATURES

LIMESTONE FEATURES

- SPALLING / CRACKING OF LIMESTONE COPING &

DETERIORATED JOINTS

Page 21: LIMS Conditional Assessment Presentation; 4-9-14

MISCELLANEOUS ITEMS

MISCELLANEOUS ITEMS REQUIRING REMEDIATION

- EXISTING PARAPET WALL REMEDIATION

- EXISTING STAIRS AT EAST AND WEST SIDES OF

BUILDING REMEDIATION

- EXISTING CONCRETE STAIRS ACCESSING BASEMENT

- EXISTING FRONT ENTRANCE STAIRS

Page 22: LIMS Conditional Assessment Presentation; 4-9-14

SUMMARY

REQUIRED REMEDIATION ITEMS

- CONCRETE SPALLING AT FIRST FLOOR FRAMING

- BRICK WALL CRACKING

- WATER INFILTRATION AT WINDOWS & ROOF

- EXTERIOR CHIMNEY REMOVAL

- EXTERIOR STEEL LINTEL REPLACEMENT

- CONCRETE KNEEWALL CRACK REPAIR AT BUILDING

BASE

- REPAIR OF DELAMINATED LIMESTONE FEATURES

- AMOUNT OF REPAIRS DEPENDENT ON RESULTS OF AN

EXTENSIVE STRUCTURAL SURVEY

- REINFORCING OF PARAPET WALL

- EXISTING FRONT ENTRANCE AND BASEMENT STAIR

Page 23: LIMS Conditional Assessment Presentation; 4-9-14

SUMMARY

ANTICIPATED STRUCTURAL RENOVATION ITEMS

- ROOF STRUCTURE REINFORCING FOR NEW MEP

SYSTEMS

- FLOOR STRUCTURE REINFORCING FOR NEW MEP

SYSTEMS

- NEW LINTELS SUPPORTING LARGER WALL OPENINGS

- NEW EXTERIOR RAMPS / STAIRS

- NEW ELEVATOR

- TOILET ROOM RENOVATIONS AND OTHER

MISCELLANEOUS CODE REQUIRED ROOM UPGRADES

Page 24: LIMS Conditional Assessment Presentation; 4-9-14

QUESTIONS