line - load reactors...line reactors data sheet 400v, 3 phase, 4% impedance 230v, 1phase, 4%...
TRANSCRIPT
Standarts
Rated Voltage
Rated Current
Rated Power
Rated Frequency
Phase
Impedance
Tolerance of Inductance
Thermal Strength
Linearity
Protection Class
İnsulation Class
Impregnation
Cooling
Ambient Temperature
Humidity
Altitude
Design
Winding
Terminals
TECHNICAL DATA
: TS EN61558-2-20, TS EN60076-6
: CE Conformity
: 230V...400V...600V...1000V
: 4A.................................3000A
: 0,37kW.....................1600kW
: 50Hz
: 1 - 3
: 4% or demanded
: ±5%
: 1,15In continuous
: 1,4In above
: IP00
: F Class 1550C
: H Class Varnish Vacuum Impregnation
: Natural
: 400C
: 95%
: 1000m
: 3 phase, Iron Cored, with air gap
: Copper, Aluminium
: Terminal blocks, Cable lugs or Copper bars
Line-load reactors help to keep your equipment to run longer by absorbing many of the disturbances, especially the spikes coming from the electrical system, which otherwise damage or shut down your inverters, variable speed controllers, or other sensitive equip-ments. They are the modern technological solution to the problems of the inverter and drive applications. They are very e�ective at reducing harmonic distor-tion produced by inverters and drives.
• Decrease the ratio of dv/dt• Decrease peak voltage• Increase the efficiency of the motor• Decrease the noise of the motor• Decrease over heating of the motor• Lengthens the isolation life of the motor
• Decrease the harmonic distortion • Absorb the surges and the spikes• Decrease voltage peaks• Improve the true power factor• Lengthens the operating life of the inverters
THE BENEFITS OF LINE REACTORS THE BENEFITS OF LOAD REACTORS
LINE - LOADREACTORS
LINE REACTORS DATA SHEET
400V, 3 PHASE, 4% IMPEDANCE
230V, 1PHASE, 4% IMPEDANCE
GKRTN3704
GKRTN5504
GKRTN7504
GKRT1N104
GKRT1N504
GKRT204
GKRT304
GKRT404
GKRT504
GKRT704
GKRT1104
GKRT1504
GKRT1804
GKRT2204
GKRT3004
GKRT3704
GKRT4504
GKRT5504
GKRT7504
GKRT9004
GKRT11004
GKRT13204
GKRT16004
GKRON3704
GKRMN5504
GKRMN7504
GKRM1N104
GKRM1N504
GKRM2N204
GKRM304
GKRM404
kW
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
45
55
75
90
110
132
160
0,37
0,55
0,75
1,1
1,5
2,2
3
4
V
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
230
230
230
230
230
230
230
230
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1
1
1
1
1
1
1
1
A
1,5
2
2,5
3
4
6
8
10
12
16
25
35
40
50
63
80
100
110
160
200
220
260
320
4
6
8
10
12
20
25
30
mH
20
15
12
10
7,4
4,9
3,7
3,0
2,4
1,84
1,20
0,84
0,73
0,59
0,47
0,37
0,29
0,27
0,18
0,15
0,13
0,11
0,092
8
5
4
3
2,5
1,5
1,2
1
mm
120 x 130 x 70
120 x 130 x 70
120 x 130 x 75
120 x 130 x 70
120 x 130 x 70
120 x 130 x 80
120 x 130 x 80
150 x 150 x 85
150 x 150 x 80
150 x 150 x 100
150 x 180 x 100
180 x 215 x 120
180 x 225 x 125
180 x 160 x 130
240 x 205 x 140
240 x 210 x 150
240 x 210 x 160
260 x 210 x 170
300 x 260 x 170
300 x 260 x 185
300 x 260 x 200
300 x 260 x 210
360 x 305 x 210
84 x 100 x 75
84 x 100 x 80
84 x 100 x 80
96 x 120 x 95
96 x 110 x 95
95 x 110 x 90
96 x 105 x 120
96 x 100 x 120
CODE POWER VOLTAGE PHASE CURRENT INDUCTANCE DIMENSIONSW x H x D
Reactors up to 3000A are available
w
W
H
D
d
LINE - LOADREACTORS
LOAD REACTORS DATA SHEET
400V, 50Hz, 3 PHASE
230V, 50Hz, 3PHASE
MKRT1N1
MKRT1N5
MKRT2
MKRT3
MKRT4
MKRT5
MKRT7
MKRT11
MKRT15
MKRT18
MKRT22
MKRT30
MKRT37
MKRT45
MKRT55
MKRT75
MKRT90
MKRT110
MKRT132
MKRT160
MKRMN75
MKRM1N1
MKRM1N5
MKRM2
V
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
230
230
230
230
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
kW
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
45
55
75
90
110
132
160
0,75
1,1
1,5
2,2
A
3
4
6
8
10
12
16
25
35
40
45
63
80
100
110
160
200
220
260
320
4
6
8
10
mH
4
3
2,4
1,5
1,4
1,2
0,9
0,55
0,40
0,35
0,30
0,24
0,18
0,15
0,12
0,09
0,07
0,06
0,05
0,04
2
1,7
1,2
1,0
mm
120 x 130 x 75
120 x 135 x 75
120 x 130 x 80
120 x 130 x 80
150 x 150 x 90
150 x 155 x 85
150 x 180 x 90
150 x 180 x 95
180 x 160 x 105
180 x 155 x 120
180 x 160 x 130
240 x 210 x 145
240 x 210 x 155
240 x 210 x 160
240 x 210 x 160
300 x 260 x 180
300 x 260 x 190
300 x 260 x 200
300 x 255 x 200
360 x 310 x 200
120 x 130 x 70
120 x 130 x 70
120 x 130 x 80
120 x 130 x 80
CODE VOLTAGE PHASE MOTORPOWER CURRENT INDUCTANCE DIMENSIONS
W x H x D
Reactors up to 3000A are available
w
W
H
D
d
LINE - LOADREACTORS