ll212x, ll217x, ll234x leds ip20 60hz · 11 13 12 psu 5 n 2 3 n/a n/a 1 o20 psu 7 psd 7 30 45 7 max...
TRANSCRIPT
-
© 04/ 2020, Signify Holding All rights reserved
Printed in PolandData subject to change without noticeKeep for future reference: www.philips.com/lighting
LL212X, LL217X, LL234X
CoreLine Trunking Gen2
442710401340
indoor 220V240V
50Hz60Hz
Max.35°CMin.
-20°CLEDs
1/4
L1
A
7 mm
A
130 mm
O2
IP20IK02
L1
30S PSU 3.000 19 2,3
53S PSU N/HE 5.300 34 2,3
80S PSU N/HE 8.000 50 2,3
30S PSD/SRD 3.000 19 2,4
53S PSD/SRD N/HE 5.300 34 2,4
80S PSD/SRD N/HE 8.000 50 2,4
45S PSU N/HE 4.500 27 2,8
80S PSU 8.000 50 2,8
120S PSU N/HE 12.000 80 2,8
45S PSD/SRD 4.500 27 2,9
80S PSD/SRD N/HE 8.000 50 2,9
120S PSD/SRD N/HE 12.000 80 2,9
90S1xPSU 9.000 54 5,4
160S 1xPSU 16.000 100 5,4
240S 1xPSU 24.000 160 5,4
90S 2xPSU 9.000 54 5,5
160S 2xPSU N/HE 16.000 100 5,5
240S 2xPSU N/HE 24.000 160 5,5
90S 1xPSD/SRD 9.000 54 5,6
90S 2xPSD/SRD 9.000 54 5,7
160S 1xPSD/SRD N/HE 16.000 100 5,6
160S 2xPSD/SRD N/HE 16.000 100 5,7
240S 1xPSD/SRD 24.000 160 5,7
240S 2xPSD/SRD N/HE 24.000 160 5,8
3400 500 - 800
500 - 800LL217X
LL234X
Luminare type
LL212X
1700
1130
System flux [lm] A [mm] L1 [mm]Wattage [W]
200 - 400
267 mm
GLOWWIRE850°C
(A - 2 x L1) max
(A - 2 x L1) max (A - 2 x L1) max
min. 1 hook per luminare
Prevent water from entering on or in the iluminare atinstallation and during use of the luminaire.
A A
P1
O20
max 2,5 mm2
STARTER KIT
Starter kit is ordered separatelydepending on the matching version
PZ2
Steel wire
*its not part of starter Kit*can be ordered as an accessory
5 and 7 wires 9 wires
45
80
95
50
SYSTEM IP LL200X
IP20
IP40OPTICAL AREA
ONLY
-
© 04/ 2020, Signify Holding All rights reservedPrinted in Poland
Data subject to change without noticeKeep for future reference: www.philips.com/lighting
442710401340
2/4
x2Drawing Accesorries2a LL200Z MB-SW
2b LL200Z CB2c LL200Z SMB2d LL200Z PB2e LL200Z SMB-TPM SET
3
5b
43
21
12a
2b
x2x2
2c 2d 2e
Open the 6 clips for one optics*
31
2
5a
5c
7a
6
2
2 2
58
9
6
8
8
3
4
Installation - all steps
1011
13 12
PSU 5
N2
3
N/A N/A
1
O20
PSU 7 PSD 7
3045
7max 2,5 mmmin 1,5 mm
2
2
max Ø 15 mm
N2
31
DA DA
7c
N2
31
NN LL
max 2,5 mmmin 1,5 mm
2
2
7b
2b
PZ2
P1
x6
1
The second power connection option The third power connection option
4
The first power connection option
* Opening the luminaire requires disconnecting all catches in all optical systems
-
© 04/ 2020, Signify Holding All rights reserved
Printed in PolandData subject to change without noticeKeep for future reference: www.philips.com/lighting
442710401340
3/4
6
6
611 NEXT TRUNK 6
SP - Select phase (factory settings is L1)
L1
L2
L3
SP
612
L1
L2
L3
SP
SP
1
613
68
3
1
2
2020
69
1
2
NEXT TRUNK
180°OK
1ST TRUNK
Connection Trunk to TrunkOK
P1
Open the 6 clips for one optics*
10
PSD 9 SRD 7
7d
LAST TRUNK
614
Blind cover - installation
15Rotation of LED panel (for asymmetric optic only)
SAFETY CABLE
OPTIC PANEL
90v90v
Removal of two safety cords
Insertion of two safety cords after turning the panel 180v
Turning the panel 180v
180v16a
N2
31
LL NN
DA DA
7e
N2
31
SR+ SR-
7f
N2
31
LL NN
DA DA
max 1,5 mm2
3045
7max 2,5 mmmin 1,5 mm
2
2
max Ø 15 mm
SRD 9
PZ2
x6
* Opening the luminaire requires disconnecting all catches in all optical systems
-
© 04/ 2020, Signify Holding All rights reserved
Printed in PolandData subject to change without noticeKeep for future reference: www.philips.com/lighting
442710401340
4/4
16b 16d
2
1
3
P1
x6
90v
4
16c
Open the 6 clips for one optics
180v
SAFETY CABLE
4
32
90v
1
16d 16e 16f
Insertion of two safety cords after turning the panel 180v
Removal of two safety cords
I nom
Time (us)Tref
I max
I mains (A)
Inrush current
TYPE
53
S 1
xPS
U (
36
W)
30
S/4
5S
1xS
RD
(3
5W
)
90
S 2
x S
RD
(3
5W
)
30
S/4
5S
1xP
SD
(3
5W
)
90
S 2
xPS
D (
35
W)
30
S/4
5S
/53
S/8
0S
1xP
SD
(6
0W
)
90
S/1
60
S 2
xPS
D (
60
W)
53
S/8
0S
1xS
RD
(6
0W
)
16
0S
2xS
RD
(6
0W
)
45
S/8
0S
1xP
SU
(7
5W
)
90
S/1
60
S 2
xPS
U (
75
W)
80
S/1
20
S 1
xPS
U (
10
0W
)
24
0S
2xP
SU
(1
00
W)
80
S/9
0S
/12
0S
1xP
SD
(1
00
W)
24
0S
2xP
SD
(1
00
W)
80
S/9
0S
/12
0S
1xS
RD
(1
00
W)
24
0S
2xS
RD
(1
00
W)
80
S/1
20
S/1
60
S 1
xPS
D (
15
0W
)
24
0S
2xP
SD
(1
50
W)
16
0S
1xS
RD
(1
50
W)
Imax [A] 14,0 21,0 42,0 23,1 46,2 25,1 50,2 21,0 42,0 19,0 38,0 22,5 45,0 10,0 20,0 4,5 9,0 5,1 10,2 5,1
Tref [μs] 250 280 280 221 221 214 214 280 280 280 280 30 30 35,9 35,9 1000 1000 760 760 760
cable Ø [mm²]
MCB B-6A 13/13 8/8 4/4 8/8 4/4 8/8 4/4 8/8 4/4 9/9 4/4 9/9 4/4 7/7 3/3 7/7 3/3 6/6 3/3 4/4
MCB B-10A 20/20 13/13 6/6 13/13 6/6 13/13 6/6 13/13 6/6 15/15 7/7 14/14 7/7 11/11 5/5 11/11 5/5 10/10 5/5 7/7
MCB C-10A 34/34 21/21 10/10 22/22 11/11 21/21 10/10 21/21 10/10 24/24 12/12 23/23 11/11 18/18 9/9 18/18 9/9 16/16 8/8 12/12
MCB B-13A 26/26 17/17 8/8 17/17 8/8 17/17 8/8 17/17 8/8 19/19 9/9 18/18 9/9 14/14 7/7 14/14 7/7 12/12 6/6 9/9
MCB C-13A 40/44 28/28 14/14 29/29 14/14 28/28 14/14 28/28 14/14 32/32 16/16 30/31 15/15 24/24 12/12 24/24 12/12 20/21 10/10 16/16
MCB B-16A 33/33 21/21 10/10 22/22 11/11 21/21 10/10 21/21 10/10 24/24 12/12 23/23 11/11 18/18 9/9 18/18 9/9 16/16 8/8 12/12
MCB C-16A 40/56 35/35 17/17 37/37 18/18 35/35 17/17 35/35 17/17 40/40 20/20 30/39 15/19 30/30 15/15 30/30 15/15 20/27 10/13 20/20
1.5 / 2.5*
Maintenance instructions
To asssure the lighting quality of this unique LED lighting concept there are a fewinstructions regading the maintenance of this LED luminaire:1. Do not touch electronic components! Electronic components are under high voltage. Electronic components are ESD sensitive.2. During installation or when maintaining the luminaire please use static free gloves to avoid marks on the luminaire.3. To remove dirt and spots use the following: Dust: only use micro fiber cloths Fingerprints, etc.: use a cleaner for synthetic materials with antistatic properties.4. Do not stare into the LED light beam.5. To avoid scratches and dirt on optical parts remove protective foil after installation.6. The luminaire shall be installed by a qualified electrician and wired in accordance with the lastest IEE electrical regulations or the nationak requirements.7. The light source of this luminarie is not replaceable: when the light source reaches its end of life whole luminare shall be replaced.8. Driver insulation: Basic according to IEC 61847-1.
* Warning! The values on the left are for 1.5 mm thick cables, the values on the right are for 2.5 mm thick cables
* Opening the luminaire requires disconnecting all catches in all optical systems