lmcs-100 lighting management...user interface 10 navigating 10 the home tab 10 the support tab 12...

106

Upload: others

Post on 27-Feb-2021

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15
Page 2: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100

v4

Lighting Management

Configuration Software User Guide

Page 3: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15
Page 4: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Contents

LMCS-100 2

Copyright 2

Welcome 3

Description 3

Operation 3

PC-Based Configuration 3

Applications 3

What's New in this version 4

Key Features 5

DLM Commissioning Software (LMCS-100) 6

Introduction 6

Target Audience 6

Users of LMCS-100 include: 6

Installing the LMCS-100 Software 7

Operating System Access Rights 7

Software Packages Needed 7

License Agreement 7

Installation from the Web 7

LMCI-100 Device Driver 8

LMCS-100 Application 8

Connecting the LMCS-100 Software to the Room 9

Running the Software 9

i

Page 5: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

User Interface 10

Navigating 10

The Home Tab 10

The Support Tab 12

The Help Tab 12

Project Explorer 12

Navigation Tree 13

Window Frames 13

Reports 15

Print a Report 15

Export a Report 16

Send via E-Mail 17

The Support Tab 17

Support Menu – Preferences 18

Help Tab 19

About 19

Change History 19

Skins 19

How to Develop a Project 21

Creating a Project Off-line 21

Creating Areas and Rooms 21

Basic Tab 22

Advanced Tab 23

Building a Room using DLM Components 23

ii

Page 6: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adding Devices 23

Controllers 23

Occupancy Sensors 24

Switches 24

Daylighting Sensors 25

Device Elements 25

Synchronizing with a Discovered Room 25

Creating a Room from Discovery 27

Discover Room 27

Working with Scenes 28

Updating DLM Firmware over BACnet 29

Requirements for Updating Firmware over BACnet 29

Starting the Bootload Process 30

DLM Project Firmware Import 31

Firmware Update Options 35

Device Class 35

Update Type 36

Initial Room and Device Status 36

Room Selection Options - Firmware Update over BACnet 36

Sorting 37

Filtering 37

“Select All Rooms” and “Select No Rooms” 39

In Progress Room and Device Status 40

BACnet Firewall Issues in Windows 42

iii

Page 7: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Symptoms of Windows Firewall Issues 43

Windows 7 Professional and Windows Vista for Business 43

Alternative Windows 7 Firewall Configuration 46

Windows XP Professional 47

Adjusting Device Parameters 52

Room Controllers 52

Small room controllers 52

Enhanced room controllers 52

Network room controllers 52

Plug load controllers 52

Working with Room Controllers 53

Basic Tab Settings 53

Advanced Tab Settings 54

Loads 54

Basic and Advanced Load Parameters 55

Normal Hours/After Hours Settings for Loads 56

Switched Load Parameters 57

Advanced Load Parameters Tab (Bottom) 58

Lamp Burn-in Time 58

Working with Occupancy Sensors 59

Dual Technology Occupancy Sensors 59

Sensor Configurations 59

Basic Tab Settings 59

Adjusting Sensor Parameters 60

iv

Page 8: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Sensitivity 60

Detection Scheme Trigger 61

Detection Scheme Retrigger 61

Personal Controls 62

Switches 62

Dimmers 62

Wall Switch Sensors 62

Working with Wall Switches 63

Working with Buttons 64

Button Configuration 64

Scene Button Parameters 65

Scene Options 65

Scene Button Properties 65

Load Button Parameters 66

Controlled Loads 66

Advanced Load Button Parameters 67

Rocker Button Parameters 68

Rocker Button Properties 69

Rocker Button Parameters Only 69

Network Button Properties 69

Dimmers 70

Working with the LMSW-105 Scene Switch 70

Basic Tab Settings for the Scene Switch 70

Advanced Tab Settings for the Scene Switch 71

v

Page 9: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMSW-105 Scene Switch 71

Controlled Loads 72

Basic Rocker Button Properties 73

Advanced Rocker Button Properties 73

Working with Buttons on a Scene Switch 74

Scene Button Properties 74

Editing a Scene 74

Working with Daylighting Sensors 76

Daylight Sensor Models: 76

Working With LMLS-400 Daylight Sensors 76

Basic Tab Settings for LMLS-400 Daylight Sensor 76

Auto Calibrate 77

Advanced Tab Settings for LMLS-400 Daylight Sensors 77

Working with Controlled Loads 78

Operation Mode - Dimming 80

Advanced Settings for LMLS-400 81

Working with LMLS-500 Daylight Sensors 81

Basic Tab Settings for LMLS-500 Daylight Sensor 82

Advanced Tab Settings for LMLS-500 Daylight Sensors 82

Working with Controlled Loads 84

Advanced Settings for LMLS-500 86

Working With LMLS-600 Daylight Sensors 87

Basic Tab Settings for LMLS-600 Daylight Sensor 87

Auto Calibrate 87

vi

Page 10: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Recommission 88

Advanced Tab Settings for LMLS-600 Daylight Sensors 88

LMLS-600 Tab Settings for LMLS-600 Daylight Sensors 89

Working with Controlled Loads 90

Other Supported Devices 93

Switches 93

Daylighting 93

Network Bridge 93

Appendix A – Devices Supported by LMCS-100 4.2 94

Room Controllers 94

Occupancy Sensors 94

Personal Controls 95

Daylighting 95

Network Bridge 95

Appendix B – Devices NOT Supported by LMCS-100 4.2 96

vii

Page 11: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15
Page 12: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 2 of 96

www.wattstopper.com16937r1

Copyright

WattStopper, reserves the right to revise this document for any reason, including, but not limited to, con-

formity with standards promulgated by various government or regulatory agencies, exploitation of

advances in the state of the technical arts, or the reflection of changes in the design of any equipment,

techniques, or procedures described or referred to herein. LIABILITY TO ANYONE ARISING OUT OF

USE OR RELIANCE UPON ANY INFORMATION SET FORTH HEREIN IS EXPRESSLY

DISCLAIMED, AND NO REPRESENTATIONS OR WARRANTIES, EXPRESSED OR IMPLIED, ARE

MADE WITH RESPECT TO THE ACCURACY OR UTILITY OF ANY INFORMATION SET FORTH

HEREIN.

This document is not to be construed as a suggestion to any manufacturer to modify or change any of its

products, nor does this document represent any commitment by WattStopper to purchase any product

whether or not it provides the described characteristics.

Nothing contained herein shall be construed as conferring by implication, estoppel or otherwise, any

license or right under any patent, whether or not the use of any information herein necessarily employs an

invention of any existing or later issued patent.

Microsoft, Windows 7, Windows XP professional and Windows Vista are trademarks of Microsoft Cor-

poration.

©2013 WattStopper – All Rights Reserved.

Page 13: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Page 3 of 96

Call 800.879.8585 for Technical Support

Welcome

Description

The WattStopper LMCS-100 Configuration Software allows users to read, store configurations and modify

DLM parameters for easy computer based configuration. It communicates from the computer to the DLM

network using the LMCI-100 Interface, which is a USB dongle that connects a computer’s USB port to the

Digital Lighting Management (DLM) local network through its RJ45 connector.

Operation

The user connects the LMCI-100 to a DLM local network by plugging an LMRJ cable connected to that net-

work into the device’s RJ45 port. To connect to the LMCS-100 software, the user plugs the LMCI-100’s

USB connector into the USB port of a PC, then starts up the LMCS-100 software. LMRJ cables should

never be plugged into an Ethernet port on a computer or wall.

PC-Based Configuration

LMCS-100 software features intuitive graphics to identify current DLM system settings, allowing users to

easily store or modify settings. With the software, users can also reconfigure DLM devices by changing

parameters and/or setting operational values. LMCS software may also be used to load new firmware with

enhanced features into DLM devices without removing installed products.

Applications

Designers can take advantage of these computer interface tools to simplify project design, startup and doc-

umentation. The LMCS software can be used to set up many advanced features of DLM devices that are

beyond the scope of Plug n’ Go, Push n’ Learn and the LMCT-100 wireless configuration tool. Fur-

thermore, the LMCI-100 and LMCS-100 facilitate preparation of commissioning documentation, which is

especially helpful for LEED projects.

Page 14: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 4 of 96

www.wattstopper.com16937r1

What's New in this version

LMCS 4.2 is intended to replace the prior version application known as LMCS 4.0. The following are

enhancements in LMCS 4.0 and later versions:

l A more modern user interface, including enhanced graphical icons to indicate various devices, and

more intuitive user interface for selecting parameters (for example: using checkboxes to indicate

enabled options rather than ‘magic numbers’ such as 0xFF)

l Documentation and User Interface Tool Tips for all devices and parameters

l A redesigned database for storage of information to facilitate improved query and reporting fea-

tures

l Support for Daylighting devices

l An online User’s Guide

l Ability to “Discover” all supported devices in the room, and then utilize the ‘saving’ feature to

retrieve and then save devices to a database. Database storage shall persist for use in a later ses-

sion, such that it may be utilized to restore data in case of data loss or device replacement in the

field.

l Reports

l CAD Import

l Experimental support of BACnet access to room devices

Page 15: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Page 5 of 96

Call 800.879.8585 for Technical Support

Key Features

The primary functions from LMCS 4.2 include:

l Ability to document a ‘project’ made up of multiple virtual ‘areas’, which may in turn contain addi-

tional ‘areas’ or ‘rooms’. A room is then used as a container for a set of DLM devices. This doc-

umentation may be saved to disk for later retrieval. Through this process an entire project utilizing

DLM devices throughout the facility may be documented in advance, or post installation via dis-

covery.

l Capability of saving all parameters from all supported DLM devices on an IRB network prior to the

boot load, as well as on user command. (See Appendix A.)

l Capability of performing a ‘boot load’ (aka firmware update) of all supported devices in the room to

the latest available firmware for the given device.

l Capability of restoring all parameters to all supported DLM devices on an IRB network after a boot

load, as well as on user command.

l Ability to communicate to a ‘Room Network’ (IRB) of WattStopper DLM devices via a connection

on the USB port of the computer, utilizing the LMCI-100 Digital Computer to DLM interface.

l Ability to display and control Load status for loads on a Room Controller, as well as current power

usage for Room Controllers which support this data.

l Support for a specific set of DLM devices. (See Appendix A.)

l For each supported device, the baseline of configuration parameters should be at a minimum the

parameter set that is supported by the LMCT device handheld programmer.

l In addition to the standard baseline parameters, there is provisions for additional parameters to be

set via an ‘Advanced’ or ‘Technician’ mode of operation, which will allow further ability to configure

devices. (All parameters are device specific.)

l Ability to generate a number of advanced reports including Room Controller Settings, Occupancy

Sensor Settings, Switch Settings and Load Bindings reports.

Note:

A list of devices supported by LMCS 4.2 are listed in Appendix A.

A list of devices NOT supported by LMCS 4.2 are listed in Appendix B.

Page 16: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 6 of 96

www.wattstopper.com16937r1

DLM Commissioning Software (LMCS-100)

Introduction

The Digital Lighting Management Commissioning Software (LMCS-100) provides the capability to view

and change DLM device parameters either while online with the devices on the local network or offline (not

connected). The software may be used to commission a site for later download or directly connect to the

local network in a room to read and write directly to the devices. LMCS-100 software requires a direct con-

nection to any open RJ-45 port for connection to the room and the LMCI-100 USB adaptor for connection

to a personal computer. The LMCS parameters Read and Send via BACnet/IP are also a supported con-

nection method in LMCS v4.1.

Commissioning is accomplished in two ways: offline and online. In offline commissioning, a project is first

created and modified without connection to the actual IRB device network. In this way, much of the work

in setting up device parameters can be done prior to loading at the commissioning work site.

Online commissioning has the benefit of using the Discovery feature of the LMCS-100 software. Once

connected to the IRB network, the Discovery automatically gathers information about the devices on the

network and the current parameter values for each device. From the discovered devices a room can be

instantly created in a project or area that is an exact model of the current network. Device parameters can

be changed and uploaded directly to the connected network.

This document will guide the user in installing and accessing the features of the LMCS-100 software. It is

not intended to provide detailed information about the function or operation of the DLM room devices nor

their parameters. For detailed information about applying DLM and use of the many available settings

and features see the DLM Design Guide.

Target Audience

Users of LMCS-100 include:

l Project Managers – who document large projects (pre-commissioning) to help generate submittals

and parameter sets that can be used in later field commissioning

Page 17: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

DLM Commissioning Software (LMCS-100)

Page 7 of 96

Call 800.879.8585 for Technical Support

l Field Service / Installers – who configure DLM devices on the job site perform, field firmware

updates, and diagnose issues

l Sales / Sales Support / Sales Representatives – who present DLM features and best practices

l Commissioning Agents – who will document (and modify) the field configuration of devices and gen-

erate reports based on those configurations

l Building Owners / Operators – who want to configure rooms after installation and maintain device

configuration information

Installing the LMCS-100 Software

Operating System Access Rights

The LMCS-100 software is targeted for the Microsoft Windows 7 operating system platform, suitable for

installation and use on a standard notebook (or desktop) computer.

As with all Microsoft® Windows 7, Windows XP professional and Windows Vista systems, in order to

install the software the installer must have local administrator access rights to the computer. If your com-

puter is administrated by your company’s IT department, a qualified IT representative may need to per-

form the installation.

Software Packages Needed

The following software packages are needed for correct operation of the LMCS-100 application.

l LMCI-100 Device Driver

l Microsoft .NET Framework 4

l LMCS-100 Application

License Agreement

By installing the LMCS-100 software you are agreeing to the terms in the license agreement which can be

found in the “license.pdf” document in the top level directory of the CD.

Installation from the Web

Using any of the common browsers, download the installer from the following address:

http://apps.wattstopper.com/software/LMCS100v4/

Page 18: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 8 of 96

www.wattstopper.com16937r1

If you will be using the LMCI-100 device then you will need to download both the LMCI-100 Device Driver

and the LMCS-100 installer. The LMCI-100 Device Driver should be installed before inserting the USB

device into the computer and before running LMCS-100.

If LMCS-100 is to be used for documentation purposes only, then you may skip the LMCI-100 installation

and proceed directly to the LMCS-100 installation.

After the download is complete, do the following to install the software:

Follow the instructions on the screen by first installing the LMCI-100 drivers (you can skip this step if they

have been installed previously) and then installing the application. The software will start up automatically

once the installation is complete, a new Icon (called LMCS-100) will appear on the desktop and a new pro-

gram link will be created on the Windows Startup menu.

Note 1: Internet Explorer may be configured to warn you upon the installation software that the pub-

lisher cannot be verified. This is expected and you should simply continue by clicking on “Run”.

Note 2: The installation package will automatically detect if your computer has the “.NET Framework

4.0 SP1” installed on your computer and will download it and install it if it is not found. This process can

take a very long time.

LMCI-100 Device Driver

Install the device driver by double clicking the downloaded driver file. The software will normally pop up a

temporary command line window and automatically install the driver. No other indication will be given that

the installation has finished. If a command line window is not displayed then the device installer needs to

be run again.

LMCS-100 Application

Double click the LMCS-100 MSI file downloaded from the web page above. The installer will automatically

determine the prerequisite software and install necessary packages as needed. LMCS-100 requires the

“Microsoft .NET Framework 4” in order to run. This package will only need to be installed the very first time

LMCS-100 is installed. This process may take a long time to complete. Subsequent updates will be much

faster.

Page 19: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

DLM Commissioning Software (LMCS-100)

Page 9 of 96

Call 800.879.8585 for Technical Support

Note : The installation of this package (should your system need it) will take several minutes to com-

plete.

Connecting the LMCS-100 Software to the Room

Plug the LMCI-100 into an available USB port on the computer running the LMCS-100 software. Plug an

LMRJ cable from the DLM Local Network into the RJ45 port on the LMCI-100.

Note: You can start the software without the LMCI-100 USB dongle connected but the software will be

in OFFLINE mode. In order to communicate with the DLM network and subsequently upload or down-

load commissioning information to the network, the LMCI-100 must be connected to the computer's

USB port before the software is started.

Running the Software

Start the LMCS-100 software by either double clicking on the green LMCS-100 icon on your desktop or by

selecting the program via the Windows Start menu.

The LMCS-100 application will automatically start up on the Home Tab and a 'New Project' is auto-

matically opened.

Page 20: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 10 of 96

www.wattstopper.com16937r1

User InterfaceThe user interface consists of the following major sections.

The top portion of the LMCS-100 interface displays a ribbon view, or menu/toolbar view, which are used to

access features. The menu is divided into three tabs labeled Home, Support, and Help. You can step

through the tabs by clicking on the title of any tab and it will appear on top of the other tabs.

Navigating

The ribbon view can be minimized by clicking the minimize button at the top right hand corner of the screen to show only tab names on the ribbon, or maximize the LMCS-100 so that it takes up the entire

computer screen.

The Home Tab

Home Menu - The most common menu features of the User Interface are shown as icons below the menu

bar under the Home heading.

Toolbar

ButtonIcon Function

NewCreates a new project. If a project is currently open, you will be offered an

opportunity to save the current project before opening a new project.

Recent Opens the Most Recently Used list.

Open Opens an existing project.

Save Save the file project that is currently open and all changes to it.

Save As Saves the current project under a new file name.

Page 21: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

User Interface

Page 11 of 96

Call 800.879.8585 for Technical Support

Toolbar

ButtonIcon Function

Import

CADImports a CSV file exported from CAD into the project.

Paste Pastes the last copied or cut Area, Room or Device into the current context.

Cut Deletes the currently selected item and puts it on the clipboard.

Copy Copies the currently selected item and puts it on the clipboard.

Delete Deletes the currently selected item.

RefreshRefreshes the navigation tree and display data. Click the Refresh button after

changing values such as in the Device Grid.

Project

Opens a dialog box where information about the project can be edited. Enter a

name for the project in the Name text box. Enter detailed information about

the project in the Project Notes text box.

WiringOpens a Typical Wiring dialog box where you can add or remove devices and

enter detailed wiring information.

NetworksOpens a dialog box where information about BACnet routers, model names

and their location are displayed.

Device

Grid

Opens the device grid editor. This is useful for making large scale property

changes.

ReportsOpens a dialog box where you select various reports for viewing on the screen,

printing, or exporting to a file.

Device

Pairing

Provides a way using a hand-held scanner to scan Serial Number bar codes on

the Device Pairing Report.

ExitCloses the current project. You will be prompted to save the project if you have

not already done so.

Page 22: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 12 of 96

www.wattstopper.com16937r1

The Support Tab

Support Menu - Provides options to upgrade the firmware in all DLM room

devices and set user preferences within the LMCS-100 software applic-

ation. Refer to Support Menu for further information.

Toolbar

ButtonIcon Function

Update

Firmware

Opens the update firmware dialog box. This is used to send new firm-

ware to the DLM room devices.

Preferences Allows selection of custom user preferences for LMCS-100.

The Help Tab

Help Menu - provides access to information about the LMCS-100 software, change history and the selec-

tion of Skins, which allow you to change the look and feel of the application screens. Refer to Help Menu

for further information.

Project Explorer

The left side of the LMCS-100 interface shows the Project Explorer. The Project Explorer provides hier-

archical access to a project with multiple levels of Areas, Rooms, Devices and Sub-devices.

Page 23: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

User Interface

Page 13 of 96

Call 800.879.8585 for Technical Support

Navigation Tree

The navigation tree displays all the DLM components in the project. Expanding the navigation tree will

always display the hierarchy of the open project. This tree view of the project can be used to select an

area, room or device for focus in the right hand screen frame. From here you can create and view various

DLM components in the project.

Note: Until a project is developed, it will only display the first item, which is New Building.

Each node in the device explorer represents any one of these items and for each item selected, a property

view will be displayed in the right hand screen frame based on the requirements of the selected node.

Window Frames

Top Right - The top right-hand section of the LMCS-100 interface is used to display information about the

device: name, Device Type, Serial Number, Description and Location. This top section is the same for all

devices.

Button Icon Function

Read Read all device parameters

Send Send all device parameters (required after any programming changes).

Status Gets the latest status values from the device (varies with the device).

Ping Causes the device to identify itself by either flashing its LEDs or blinking its Loads.

Page 24: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 14 of 96

www.wattstopper.com16937r1

Below the basic properties section are device specific properties that may contain 1 or 2 tabs labeled Basic

or Advanced. These properties often affect the function of the device.

For more complicated devices, another series of tabs may be displayed such as Loads or Buttons.

Right - The large section on the right-hand side of the LMCS-100 interface is used to display information

and properties about the rooms and devices that are added to the project, as well as configure the devices.

Right Bottom - The right bottom area of the LMCS-100 interface provides access to more advanced fea-

tures. Basic, Advanced and Technician tabs appropriate to the device.

Bottom- The bottom portion of the LMCS-100 interface displays status messages about the selected com-

ponents.

At the very bottom of LMCS-100 is a status bar that provides feedback for real time events on the left side.

On the right side of the status bar is a new “Connection” drop down list offering available connection

options for either the LMCI-100 or BACnet.

Refer to Creating a Project Offline for more information.

Note : The window panes dividing the left and right side of the interface can be adjusted. You have the

flexibility of resizing these frames as you like, so it is not mandatory that these window panes remain

permanently in its default location. Use the slider bar to adjust these panes. You can also minimize the

ribbon at the top to show only tab names. Click the minimize button (Ctrl+F1).

Page 25: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

User Interface

Page 15 of 96

Call 800.879.8585 for Technical Support

Reports

The LMCS-100 software provides you with the ability to select various reports for viewing , printing, or

exporting to a file. With a project open, from the home screen click on the Reports icon in the menu bar to

open a list of available reports.

Click on a report to view it.

Note : Reports specific to an Area or a Room can be selected by right clicking on an Area or a Room in

the tree view to choose the report specific to the selected Area or Room.

Print a Report

With a report open on the screen, click on the Quick Print icon on the menu bar to send the report to

your default printer. Or, click on the Print icon to open the print dialog box.

Page 26: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 16 of 96

www.wattstopper.com16937r1

Export a Report

To export a report that is open, click on the Export icon pull down menu on the menu bar and select a file type to export. The default is PDF however the report can be exported in a variety of other file types if

desired. Use the Save As dialog box to select a location to save the exported report file.

Or, click File - Export Document from the main menu and choose an export file format from the list of

options.

Page 27: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

User Interface

Page 17 of 96

Call 800.879.8585 for Technical Support

Send via E-Mail

With a report open on the screen, click on the Send via E-Mail icon on the menu bar to send the report via E-Mail.

The Support Tab

Support Menu - Provides you with the ability to upgrade the

firmware in all DLM room devices and set user preferences

within the LMCS-100 software application.

Update Firmware - Click on the Update Firmware icon to open

the update firmware dialog box. This will be used to send new

firmware to the DLM room devices.

Warning - Updating firmware is an advanced feature and should only be performed under direction from

WattStopper Technical Support.

Prior to starting the Firmware Update,you will be prompted to ‘save’ parameters from the field devices.

After the Firmware upgrade is complete, you will be prompted to ‘restore’ parameters to the field devices.

As a best practice, it is recommended that room devices should be discovered first before performing a

firmware update. This allows the room parameters to be sent back to the room following the firmware

update and it also preserves the device serial number in case there are issues during the firmware

upgrade.

Page 28: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 18 of 96

www.wattstopper.com16937r1

Accept the default settings and then click the Update button to start the process. The Upgrade Device Firmware pane will open and display the firmware status of the discovered devices.

Check the box next to each device that you wish to update. Then click the Upgrade button

to start the update.

l Discover -

l Recover –

Support Menu – Preferences

Click on the Set Preferences icon.

Checking the Show Technician Pages will display Technician Pages under the device settings. Uncheck

this box to remove Technician Pages from showing under the device settings. Click Close to return to the

main menu.

Checking the Show Group D Devices will display Group D Devices under the device settings. Uncheck this

box to remove Group D Devices from showing under the device settings. Click Close to return to the main

menu.

Page 29: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

User Interface

Page 19 of 96

Call 800.879.8585 for Technical Support

Check the Show Network Controllers (300 Series) to display the 300 series of network controllers under the

device settings. Uncheck this box to remove this from showing under the device settings. Click Close to

return to the main menu.

Help Tab

About

Provides information about the version of the LMCS-100 software that you are using.

Change History

Clicking on Change History will open a browser window detailing the change history of the LMCS-100 Wat-

tStopper DLM Configuration Software. Specific release version numbers, software improvements, and

fixes are discussed in detail.

Skins

The Skins toolbar provides access to a wide selection of skins that can change the look and feel of the

LMCS-100 software.

Page 30: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 20 of 96

www.wattstopper.com16937r1

l To change a skin, hover your mouse over a skin and click on it, or use the down arrow to view addi-

tional skins. The basic look and feel of the software can be changed at any time.

l Click the left and right arrows to scroll through the skins.

Page 31: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 21 of 96

Call 800.879.8585 for Technical Support

How to Develop a Project

Creating a Project Off-line

The LMCS software can be used to create a Project file prior to the equipment being installed in a

building. In this way, much of the work in setting up device parameters can be done prior to loading at the

commissioning work site.

In offline commissioning, a project is first created and modified without connection to the actual

DLM device network. In this way, much of the work in setting up device parameters can be done prior to

loading at the work site.

When creating the project, areas and rooms are created in the project and devices are selected from the

Add Devices menu to build a model of the system to be configured. Device parameters of the individual

DLM devices can then be modified and saved.

A meaningful name should be given to the project by typing in the Name: box at the top of the right hand

screen frame.

The navigation tree on the left side of the screen will always display the hierarchy of the open project. This

tree view of the project can be used to select an area or room for focus in the right hand screen frame.

Creating Areas and Rooms

Areas can represent general groupings of rooms in a facility such as 2nd Floor or South Wing.

Page 32: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 22 of 96

www.wattstopper.com16937r1

Actions that are available for an Area are:

l Add Area – adds new Area immediately below the currently selected item

l Add Room – adds new Room following the last Room below the currently selected Area

l Delete Area – deletes the current Area. Disabled if the current Area is the Root node

Adding an Area to the Project

To add an area to the project:

l Click on the Add Area button.

Note that a new icon appears in the navigation tree. The new icon will be added below the icon that is

presently selected. Similar to the top level project icon, the area can be given a meaningful name by typ-

ing in the Name: box while the area is selected in the tree.

Adding a Room to the Project

1. Highlight the Area in the tree under which you wish to add a new room.

2. Click on the Add Room button. 3. The new Room will be created within the selected Area.

4. Highlight the room, then type a meaningful name for the new room in the text box.

5. Repeat the process to add all necessary rooms to this area or click on the new room to begin adding

DLM devices to the room.

Basic Tab

Each Room screen provides a text box labeled Notes: under the Basic tab where you may explain the

intended sequence of operation for the room. It is strongly recommended that you take advantage of this

field and provide information about why the room being configured as it is and the intended operation

based on the various settings of the room devices.

Page 33: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 23 of 96

Call 800.879.8585 for Technical Support

Advanced Tab

The Advanced Tab is intended for specialty applications where basic parameters are insufficient, most

applications will not require Advanced parameters.

Building a Room using DLM Components

Adding Devices

The Add Devices menu provides access to all of the available DLM room

devices that can be added to a room. Use the pull down menus to add the

devices to the room.

Controllers

There are several models of room controllers in the Add

Room Controller gallery. These are divided by functional

type: Small Room Controllers, Enhanced Room Con-

trollers and Plug-In type Load Controllers. Two are small

room controllers identifiable by the number of loads con-

trolled by each respectively, enhanced room controllers

with dimming capability and two load plug-in type room

controllers.

Page 34: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 24 of 96

www.wattstopper.com16937r1

Occupancy Sensors

The Add Devices - Occ. Sensor gallery currently holds a number of dif-

ferent occupancy sensor models corresponding to whether they are PIR,

ultrasonic, or dual technology and whether they are wall or ceiling moun-

ted.

Switches

The Add Devices Switch gallery holds eight models of switches identifiable by the number of buttons on

each switch and whether they are Dimmers or Wall Switch Sensors.

Page 35: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 25 of 96

Call 800.879.8585 for Technical Support

Daylighting Sensors

The Add Devices Daylighting Sensors gallery holds the LMLS-400,

LMLS-500, LMLS-600 and LMIO-301 Digital Photocell Input model.

Device Elements

Note that as devices are selected, icons appear in the tree view under the room. Some devices such as

Room Controllers and Switches have additional elements that can be displayed by clicking the down-arrow

beside the device. Room controllers have load elements and switches have button or scene elements.

Note that when working off-line, some fields that are not available

will be grayed out. These fields will be active either while LMCS

is connected live to the room or after an installed room has been

discovered by LMCS.

Synchronizing with a Discovered Room

A room that is created off-line is an image of the intended installed

room. Until the off-line image is synchronized with the actual

installed DLM devices, it is documentation only. After syn-

chronization, it will be capable of live interaction with the room

Page 36: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 26 of 96

www.wattstopper.com16937r1

devices and allow adjustment of settings. It is intended that there is a one to one relationship between the

DLM devices in the off-line created room and the discovered room.

1. Click on the room in the tree view that is to be synchronized to open the room view in the right hand

screen frame.

2. Click on the Sync Devices button above the right hand screen frame to start the process.

3. A dialog box will open that will allow you to monitor the process.

4. If the off-line room and the discovered room do not match, an error message will result. Click

Cancel, resolve the difference and try again.

Click the Finalize button to perform the synchronization. Note that once the process is com-plete the documented devices in the room will now exhibit the settings and serial numbers of the actual

installed devices.

Page 37: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 27 of 96

Call 800.879.8585 for Technical Support

Creating a Room from Discovery

Online commissioning has the benefit of using the Discovery feature of the LMCS-100 software. Once

connected to the IRB network, the Discovery automatically gathers information about the devices on the

network and the current parameter values for each device. From the discovered devices a room can be

instantly created in a project or area that is an exact model of the current network. Device parameters can

then be changed and uploaded directly to the connected room.

Discover Room

From the Home screen in a new Project, click the Discover button located above the right hand screen

frame.

This will open a dialog box that will monitor the discovery process.

Page 38: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 28 of 96

www.wattstopper.com16937r1

After the discovery process is complete, click the Close button to continue. Click on the newly discovered

room in the tree view to open it in the right hand screen frame.

Note that after a discovery, LMCS will display a snapshot of the room device parameters and status that

were in effect at the time the discovery was completed. The parameters and settings can be updated in

LMCS at any time either individually per device using the Read button for a device or globally for the room

using the Read All Devices button.

Working with Scenes

Rooms that have dimming capable room controllers will include a box at the top of the screen for man-

aging scenes in the room. Provided the LMCS software remains connected to the room, the Scenes func-

tions will be live in real time.

Activate a Scene - highlight a scene number in the list and click the Activate button to initiate the scene in

the room.

Edit a Scene - highlight a scene number in the list and click the Edit button. The lights in the room will

fade to the levels currently saved in the scene. Note that factory default for scenes 1 - 4 is 100%, 75%,

50% and 25% for all loads respectively. The Scene Editor box will open.

Page 39: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 29 of 96

Call 800.879.8585 for Technical Support

By default all loads in the room are selected to participate (Follow) in each scene. Click on the check box

for a load to exclude or include it in the scene.

Target Level - use the slider to adjust the light level for a load. The lights will dim in real time as the slider

is adjusted. Adjust all loads for the scene then click Close.

Note: The new levels for the scene will not become active in the room until they are saved in the room

controller. Click the Send All Devices button to send the levels to the room controller(s).

Updating DLM Firmware over BACnet

Bootloading DLM devices over BACnet is a powerful new feature in LMCS-100. Instead of visiting each

room and directly connecting to the DLM network the user can now connect to an IP BACnet network and

remotely update firmware from a central location.

Requirements for Updating Firmware over BACnet

1. The MS/TP BACnet network must be tested and vetted.

2. LMCS-100 must have direct network access to the BACnet network.

3. The Bridges must be documented and have the Device IDs assigned.

4. The other DLM room devices must be documented and have the Serial Numbers assigned.

WARNING: Changing the serial number on the LMBC-300 Network Bridge causes the

device to be reset to factory defaults including the BACnet communication properties.

Changing the BACnet properties can cause the bridge to loose communication with the

BACnet network. If a bridge is being replaced in the field and the serial number must be

changed to match the previous bridge then the original properties should be transferred into

the new bridge as soon as possible.

Page 40: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 30 of 96

www.wattstopper.com16937r1

As a best practice, it is recommended that room devices be discovered first before performing a firmware

update. This allows the room parameters to be sent back to the room following the firmware update and it

also preserves the device serial number in case there are issues during the firmware upgrade.

To connect to BACnet, a valid BACnet IP connection must be selected. This can be performed in the bot-

tom, right corner of LMCS-100. Choose the Network Interface Adapter that is connected to the BACnet IP

network at your location. Both wired and wireless connections can be used.

Starting the Bootload Process

To begin the firmware updating process select the “Support” tab at the top of LMCS-100 and click on the

Update Firmware toolbar button to open the Update Firmware dialog box.

Icon Function

This opens the update firmware dialog box (shown below), which

allows for some customization of firmware that is used and to send

new firmware to the DLM room devices.

Page 41: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 31 of 96

Call 800.879.8585 for Technical Support

This form provides options to choose the factory firmware that comes with LMCS-100 or to select a cus-

tom firmware folder.

l Custom Firmware Directory - The custom firmware option is often used when older firmware is

required or some other specialty project needs.

l Reset to Factory Defaults following bootloading - This option forces the DLM room to reset to

factory defaults after the firmware update. This is the recommended practice so newly updated

devices can be properly initialized. Following a successful firmware update the room programming

can be transferred.

Check the box next to each device that you wish to update. Then click the Update button to start the update.

DLM Project Firmware Import

LMCS-100 now supports importing a specific firmware version into the DLM project file. This feature

allows a project to lock in a specific firmware version that meets special requirements for certain DLM pro-

jects. To import a firmware folder into the DLM project file click the “Project” toolbar button.

Page 42: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 32 of 96

www.wattstopper.com16937r1

The Project editor is displayed. This opens a dialog box where information about the project can be

entered. Enter a name for the project in the Name text box. Enter detailed information about the project

in the Project Notes text box.

To import firmware, press the Import button and select the folder that contains the firmware you want to

use for this site. This folder must contain certain files and be formatted correctly.

Note: Only use a folder (or zipped file folder) provided by the WattStopper Engineering or Technical Sup-

port teams.

Page 43: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 33 of 96

Call 800.879.8585 for Technical Support

Once imported, the firmware can be either viewed in the file list box. The firmware can also be cleared or

exported using the 'Clear' or 'Export' buttons. The initial Update Firmware form will indicate that embed-

ded firmware will be used as shown below.

Page 44: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 34 of 96

www.wattstopper.com16937r1

Press the “Update” button to bring up the “Firmware Update over BACnet” form (if a valid BACnet con-

nection on the main LMCS-100 form was properly selected).

Page 45: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 35 of 96

Call 800.879.8585 for Technical Support

This form allows you to change the firmware for all devices in rooms with a supported bridge. Multiple

rooms can be updated at the same time. This is currently based on the number of networks.

Firmware Update Options

Device Class

The Device Class drop down allows you to choose the types of devices to be updated. Choices include: All

Devices, BAS Module, Daylighting Controller, Occupancy Sensor, Plug Load Controller, Room Controller,

Switch and Wall Mounted Sensor. By default, “All Devices” is selected.

Page 46: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 36 of 96

www.wattstopper.com16937r1

Update Type

This drop down allows you to specify what type of update will be applied to the devices. By default, the

“Upgrade” option is selected for factory firmware while “Upgrade/Downgrade” is selected when firmware

has been imported into the DLM project file.

l Upgrade – update devices only if given firmware is newer than existing firmware.

l Force Upgrade – forces firmware update if equal to or older than given firmware.

l Upgrade/Downgrade – forces upgrade or downgrade of the firmware to the given version unless it

already matches.

l Force Upgrade/Downgrade – forces all selected devices to be updated to the given version. Does

not check existing version.

For example, if the Device Class is set to All Devices, and the Update Type is set to Force Upgrade/Down-

grade, all devices in the selected rooms will be updated with the given firmware.

When the “Auto Select” option is checked, rooms will be automatically checked based on device class and

update type selections. Checking “Auto Select” also offers a quick way to tell which devices require updat-

ing by selecting different device classes and observing the checked rooms in the grid.

Initial Room and Device Status

Prior to firmware transfer all rooms and devices are marked with a status based on the selected firmware

(factory or imported firmware). These status include:

l Current – device firmware matches proposed firmware.

l Upgradeable - device firmware is older than proposed firmware.

l Downgradeable - device firmware is newer than proposed imported firmware.

l UpDowngradable - (for Rooms only) mix of devices either Upgradeable or Downgradable.

l Unsupported – no proposed firmware available for the given device.

Room Selection Options - Firmware Update over BACnet

By default, any room that has devices with out of date firmware will automatically be selected when this

form is first displayed. If more refined selections need to occur, filter and sorting tools can be used.

Page 47: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 37 of 96

Call 800.879.8585 for Technical Support

Sorting

The rooms displayed in the grid can be sorted and/or grouped by any column. To sort data by a column

click its column header. The column's current sort order is indicated by the sort glyph (a small arrow dis-

played at the column header's right edge). If the data is sorted in ascending order, the sort glyph uses an

up-arrow. When sorting in descending order, the sort glyph is displayed as a down-arrow. If the

column isn't sorted, no glyph is shown.

Room Selections displays a grid with eight columns: Room, Update, Network, Count, Device, Room,

Room Log and Status. You can click on one of these buttons title to sort by any of these eight columns, or

by using the filtering options.

Filtering

Filtering allows you to display a subset of the records in the data source that meet particular criteria. When

filtering is applied to the room grid, displayed records are restricted to those that meet the current filter

Page 48: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 38 of 96

www.wattstopper.com16937r1

criteria. Data can be filtered against single or multiple columns. Filters can be applied by selecting a

column's value from the filter dropdown, using the filter row, building a filter via the Filter Editor, or by

using the Custom Filter Dialog. The filter dropdown list is accessed by clicking on the filter button (small

funnel icon) in the column header.

The dropdown list will contain predefined values along with values of the items in the column. The most

recently used filter conditions are displayed at the top of the list. Applying a filter to a column does not

affect the filter settings of any other column. After a filter has been applied, the filter panel appears at the

bottom of the grid.

l To clear the filter, press the ‘x’.

Another way to filter data is by using the automatic filter row. This row is displayed at the top of the grid,

and data is filtered by typing text directly into this row. The filter editor allows users to build complex filter

criteria with unlimited number of filter conditions, combined by logical operators. It is accessed by right-

clicking on a column header and selected “Filter Editor” or by selecting 'Edit Filter' at the bottom right side

of the form.

Page 49: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 39 of 96

Call 800.879.8585 for Technical Support

The custom filter dialog is accessed by clicking (Custom) from the filter dropdown list. It allows users to

set filter criteria for a column. Filter criteria can consist of one or two filter conditions combined by AND or

OR Boolean operators.

“Select All Rooms” and “Select No Rooms”

The “Select All Rooms” and “Select No Rooms” buttons are convenient for selecting all or none of the cur-

rently displayed rooms.

Warning: rooms that are filtered out (hidden from the grid) will not be affected by these buttons. The total

number of rooms selected is shown to the right of the selection buttons.

Once the final selections are made, press the Start button to begin transferring firmware. Pressing “Start”

will disable the selection buttons and combo boxes, and will automatically apply a filter that only shows

rooms marked for updating. The overall progress will be displayed in the Device Progress group box just

below the Start button. The individual room and device progresses and statuses will be displayed in the

grid. Overall progress information is displayed in the list box at the bottom of the form. The rooms and

devices in the grid can have one of several statuses.

Page 50: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 40 of 96

www.wattstopper.com16937r1

In Progress Room and Device Status

During the update process all rooms and devices will show the following:

l Current – firmware is up to date, no firmware will be transferred.

l Pending - waiting to be updated to proposed firmware

l In Progress - the device is currently being updated and progress indicated by the “Device” column

l Completed - the room or device was successfully updated.

l Failed – the room or device failed to be updated. Review the room “Message List” for details of the

failure.

Note: Clicking the ‘+’ symbol opens up the room allowing you to see more details, including the list of

devices and the room message list. The room message list shows details of the firmware transfer process.

Page 51: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 41 of 96

Call 800.879.8585 for Technical Support

WARNING: It is important not to turn off your computer or allow it to sleep/hibernate during firmware

updates. If for some reason you need to stop the update process, press the Stop button. When Stop is

pressed, the devices currently in progress will finish their firmware updates, but no pending devices be

updated. There may be several minutes before the active devices can complete the update process and

allow LMCS-100 to be closed.

When the firmware updates have completed, a log of all of the status messages will be saved in same

folder as the DLM Project file. The name of the log file will have the following format: “Bootlog-yyyymmdd-

hhmmss.xml” where yyyymmmdd is the current date, and hhmmss is the current time. The data is stored

in an XML format. This data can be opened/viewed by a normal text editor, by a web browser (like Internet

Explorer), or any XML editor. It can also be imported into Excel.

Page 52: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 42 of 96

www.wattstopper.com16937r1

BACnet Firewall Issues in Windows

To protect computers from hackers most in-bound ports are closed and restricted from use. The program

that monitors this feature is called a “Firewall”. In order to allow LMCS-100 to work correctly on a BACnet

network, one or more of these ports must be opened on the computer. The default ports used in BACnet

range from 0xBAC0 to 0xBACF (47808 to 47823). On small networks generally 0xBAC0 is used by itself.

Each application that opens an in-bound port must register itself with the Firewall. Depending on user per-

missions and corporate policy, allowing this port to be opened may be restricted. If this is the case then the

Page 53: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 43 of 96

Call 800.879.8585 for Technical Support

user must contact the administrator or help desk of the organization that manages this computer. The fol-

lowing notes are primarily designed for a user that has full administrative rights on the local machine.

However, the help desk will need much of this information to assist them in properly configuring LMCS-

100 to work with BACnet.

To connect to a BACnet network, a Network Interface must be selected. This can be done at the bottom

right corner of the main LMCS-100 screen. Often, all of the computer’s Network Interfaces will be listed in

the drop down so some knowledge of the network setup for BACnet will be needed. Often times it will be

the first “wired” connection.

At this point a Windows Firewall warning may popup a dialog. This dialog is different depending on the ver-

sion of Windows that LMCS-100 is running on.

Symptoms of Windows Firewall Issues

If any of the following issues arise while using LMCS-100 with BACnet then the Windows Firewall may be

the cause.

1. Unable to discover network routers.

2. Successfully discovered routers but not Network Bridges (LMBC-300s).

3. A previously discovered or connected room or device no longer responds

The last issue could have several causes including loss of power, changes in wiring, as well as a blocking

firewall. The following directions for configuring Windows Firewall include details for both Windows 7 and

Windows XP.

Windows 7 Professional and Windows Vista for Business

Once the Network Interface is selected a Windows Firewall warning dialog will appear. Click the checkbox

marked “Private networks, such as my home or work network”. Depending on how your network is con-

figured the “Public networks” option may also need to be checked. This will allow LMCS-100 to work cor-

rectly with the BACnet network. Click “Allow Access” to complete the dialog. You will need administrative

Page 54: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 44 of 96

www.wattstopper.com16937r1

privileges to change Windows Firewall settings. If you are unable to do so then you will need to contact the

administrator or your help desk.

The easiest way to test BACnet operations is to perform a network discovery with LMCS-100. With an

empty project, click the “Discover” button on the Area form. LMCS-100 will perform a “Who-Is Router” com-

mand that should discover 1 or more BACnet networks. If at least one network is discovered then select at

least one of those networks and attempt to discover rooms (LMBC-100 Network Bridges) on that network.

If that succeeds as well then BACnet is properly configured. If at any point devices are not discovered that

are expected to appear (wiring and networking has been tested and confirmed working by a technician)

then proceed to the following Windows Firewall configuration changes.

Before making any changes to the Windows Firewall regarding LMCS-100, LMCS-100 should be shut

down. After shutting down LMCS-100 open the Windows Control Panel and click “System and Security”:

Page 55: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 45 of 96

Call 800.879.8585 for Technical Support

Under “Windows Firewall” click “Allow a program through Windows Firewall”

The list of Windows Firewall enabled applications is displayed.

Page 56: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 46 of 96

www.wattstopper.com16937r1

Scroll down the list of programs that Windows Firewall knows about and find “LMCS-100”. You may see

several different entries depending on how many older versions were installed and are still in use. You can

double-click each entry to see where it is installed. To edit or remove an entry you must click the “Change

Settings” button and possibly authenticate before being allowed to make changes. The easiest way to fix

firewall issues with LMCS is to delete the LMCS-100 entries and restart LMCS-100. When LMCS-100 is

restarted, the initial Windows Firewall warning will return. If only one checkbox was checked earlier then

check both boxes (“Private networks” and “Public Networks”).

Alternative Windows 7 Firewall Configuration

For expert users the “Windows Firewall with Advanced Security” tool can be used. This tool is part of

“Microsoft Management Console”. The easiest way to access this tool is to type “Firewall” in the Start but-

ton search box (Click the Start button and start typing).

With the tool open, select “Inbound Rules” and scroll down until the Name “LMCS-100” is found.

Page 57: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 47 of 96

Call 800.879.8585 for Technical Support

To enable BACnet communication the rule must allow an incoming UDP connection on at least a “Private”

network but may also need the “Public” network to also be enabled. It may be easiest to delete ALL

LMCS-100 Inbound Firewall Rules and then restart LMCS-100 to revisit the Firewall warning dialog.

Windows XP Professional

Once the Network Interface is selected a Windows Security Alert warning dialog will appear the very first

time LMCS-100 creates the BACnet port.

Click the “Unblock” button to allow BACnet communication for LMCS-100. Typically that is all that needs

to be done in Windows XP. To test BACnet launch LMCS-100, select the appropriate network and click

the “Discover” button on the Area form near the top. At least one or more networks should be discovered.

If one or more networks are discovered then select one or more of the networks with known and working

Network Bridges (LMBC-300s) and discovery them. All active bridges should be found.

If there is difficulty discovering networks or bridges then the Windows Firewall needs further attention.

Open “Control Panel” and click “Security Center”.

Page 58: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 48 of 96

www.wattstopper.com16937r1

At the bottom of Windows Security Center is the “Windows Firewall” configuration tool, click on it.

Page 59: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 49 of 96

Call 800.879.8585 for Technical Support

This will bring up the “Windows Firewall” configuration tool.

Page 60: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 50 of 96

www.wattstopper.com16937r1

Verify the Firewall is “On” then select the “Exceptions” tab at the top.

Page 61: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

How to Develop a Project

Page 51 of 96

Call 800.879.8585 for Technical Support

Verify that “LMCS-100” is selected as an exception to the firewall rules. If it is checked and LMCS-100 is

unable to properly connect to BACnet then delete the entry and relaunch LMCS-100.

IMPORTANT! As a safe security practice be sure to keep Windows up to date.

Page 62: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 52 of 96

www.wattstopper.com16937r1

Adjusting Device Parameters

Room Controllers

Room Controllers consist of the following:

Small room controllers

l LMRC-101, 102

Enhanced room controllers

l LMRC-211, 212, 213

l LMRC-221, 222

Network room controllers

l LMRC-311, 312, 313 (these devices are being discontinued as of 2012)

Plug load controllers

l LMPL-101, LMPL-201

Page 63: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 53 of 96

Call 800.879.8585 for Technical Support

Working with Room Controllers

Clicking on a room controller in the tree will open that device for editing in the right hand screen frame.

The Device information area holds two buttons that initiate transactions on the DLM bus. They both target

the IRB device with the same MAC address as the device selected in the Project Explorer tree.

l Device Type – Shows the device type

l Serial Number– Shows the serial number of the device

l Description - you may enter any descriptive name for the device in the text field

l Location– Text which describes the physical location of this device, such as electrical room number

Click the Status button to determine current room status such as load states

Note : Clicking on either the Basic tab or the Advanced tab will show the available parameters grouped

by their complexity.

Basic Tab Settings

l Volts - Is an input field, which requires you to input the voltage of the circuit.

l Amps - Shows amps

l Watts - This is calculated when you enter the voltage into the Volts field.

l Circuit-

l Power Totalizer -

Page 64: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 54 of 96

www.wattstopper.com16937r1

Advanced Tab Settings

l Lock Level - No Lock, PnG Lock, PnG Lock & PnL Lock

l Serial Number - Shows the serial number of the device

l Firmware version - Shows the firmware version of the device

l Hardware Version - Shows the hardware version of the device

l Date Code - This is the manufacture year and week.

l Room Profile - The current room profile being reported by the controller.

l Power Factor - Use the up and down buttons to change the value .

l Watt Change for Update - Defines the amount of change in watts before a new value is broadcast.

Use the up and down buttons to change the value .

Click the Advanced... button for Advanced Device Info.

Loads

Room controllers each contain from 1 to 3 loads based on their model number. The loads can be

accessed either by expanding a room controller in the tree or from the room controller's information frame

when the Room Controller is selected in the tree view.

Page 65: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 55 of 96

Call 800.879.8585 for Technical Support

Note: Loads are numbered 1 through 64 (Load ID) as room controllers are added to a room based on the

serial number of the room controller. However, the A, B and C load designation within a room controller is

constant and will not change. See the DLM Design Guide for a detailed explanation of load numbering.

Load tabs are color coded red, yellow and blue. These colors correspond to the actual color of the wires on

the RC used to connect the loads. Click on a Load tab on the room controller page or click on a load in the

tree view to display the load parameters.

Load ID - Shows the load ID.

Description - Shows a description of the load. Enter a unique name for this load into the text box.

Load Type - Use the pull-down menu ▼ to select: Switched, Dimmed (0-10v), HID (No Blink Warn).

Note : For the LMRC-101, 102 the only choices are switched and HID.

Room Controllers with Phase Dimming include the LMRC-221 and 222. They have the following options

under Load Type:

l Switched

l Incandescent

l Mark X

l Hi-Lume

l HID - No Blink Warning

Basic and Advanced Load Parameters

A number of Basic and Advanced load parameters have features that can be set to behave differently

based on the schedule mode of the room. While in Basic or Advanced settings, select the Normal Hours

tab to set load parameters for normal hours room mode, or select After Hours to set load parameters for

after hours room mode.

Page 66: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 56 of 96

www.wattstopper.com16937r1

Note: The normal hours/after hours room mode is typically set by a schedule running on the segment man-

ager or by the LMIO-101. This mode can also be set for testing purposes using the LMCS-100 software or

the LMCT-100 commissioning tool.

Sensor mode - The Sensor mode determines if the load can be turned on automatically by a sensor, or

only manually by a switch. Click in the Sensor Mode pull-down menu to adjust the Sensor Mode. Menu

Options ▼are ‘Follow On and Off’ and ‘Follow Off Only’.

Depending on the Load type the basic tab parameters will differ as follows:

l Switched Load - Use Blink Warn box; no Grace Time box & Trim Level can not be set

l HID No blink warning - Use Grace Time box & Trim Level settings

l Load type - Plug Load (cannot be changed)

Normal Hours/After Hours Settings for Loads

Use Blink Warn - The Blink Warning flashes the load OFF then ON one minute prior to the sensor auto-

matically turning the load OFF when the time delay expires.

l Check the box to adjust the Blink Warning. Options are ‘Enable’ (checked) or ‘Disable’ (unchecked).

Note: Switched mode will not have a Use Blink Warning box.

Trim Level - This option is not available for switched load types.

Page 67: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 57 of 96

Call 800.879.8585 for Technical Support

l Low Trim - Minimum value

Entering a Low Trim value limits how low a load is allowed to dim. This overrides any other

light level settings. The value options are 0-99% in 1% increments. This is shown in the Min

text box, where you can also enter this value. 100% to 0% range with a low trim of 5% and a

high trim of 90% means that the load output now shows 1% in LMCS at 5% the range of the

dimmer and 100% in LMCS at 90% the range of the dimmer.

Note: Switched mode will not have a Trim Level box.

l High Trim- Maximum value

Entering a High Trim value limits how high a load is allowed to dim. This overrides any other light

level settings. The value options are 1-100% in 1% increments. This is shown in the Max text box,

where you can also enter this value.

Preset Level - Entering a Preset value causes the lights to go to this light level each time they are turned

on. By default, the value is set to Use Last Level, which turns the load on to its last used level.

Fade Trip Point - For a Switched load, the only parameter that is adjustable is the Trip Point. The Trip

Point determines at what point in a ramp or fade the load turns ON or OFF. The value options are 1%,

25%, 75%, 51% or 100%. The default is 51%.

Transition Level - Menu options are: Nothing, Go To Level, Keep Timer, Last Non Zero and Relinquish.

Go To Level allows you to adjust the settings using the slider bar.

Switched Load Parameters

For a Switched load, the only parameter that is adjustable is the Trip Point. The Trip Point determines at

what point in a ramp or fade the load turns ON or OFF if a dimmer is bound to that switched load or if that

switched load is part of a scene.. The value options are 1%, 25%, 75%, 51% or 100%. The default is

51%.

Page 68: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 58 of 96

www.wattstopper.com16937r1

Advanced Load Parameters Tab (Bottom)

Lamp Burn-in Time

The Lamp Burn-In Time feature located at the top left area of the screen allows the user to burn-in, or sea-

son, all of the lamps associated with the load. This is most often done to fluorescent lamps to insure sta-

bilization of the lamp and/or dimming compatibility.

The value options are 0, 12 or 100 hours. If 12 or 100 hours is entered, then the associated lights remain at

100% light level at any time they are turned ON until the number of hours has elapsed. The light may be

turned ON or OFF as desired, however they do not respond to dimming during this time.

Page 69: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 59 of 96

Call 800.879.8585 for Technical Support

Working with Occupancy Sensors

Occupancy Sensor Models:

l LMPC-100 (Digital PIR), LMPX-100 (Digital PIR), LMUC-100 (Digital US), LMUC-200 (Digital US),

LMDX-100 (Dual Technology), LMDC-100 (Dual Technology)

Dual Technology Occupancy Sensors

Clicking on an occupancy sensor in the tree will open that device for editing in the right hand screen frame.

l Device Type – Shows the device type

l Serial Number– Shows the serial number of the device

l Description - you may enter any descriptive name for the device in the text field

l Location- Text which describes the physical location of this device, such as electrical room number

Sensor Configurations

Clicking on either the Basic tab or the Advanced tab will show the available parameters grouped by their

complexity.

Basic Tab Settings

The Basic Tab consists of the following settings:

Follow After Hours - When checked, the occupancy sensor uses the special After Hours properties when

the room goes into After Hours mode.

Detection LEDs- Check to enable detection LEDs

Occupancy State - Occupied when motion detected, Vacant when no motion detected following the

Time Delay period.

Control Type: Indicates whether this occupancy sensor will control loads directly (Load) or via scenes

(Scene). Select Load or Scene.

Page 70: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 60 of 96

www.wattstopper.com16937r1

Controlled Loads

By default the occupancy sensor will control all loads in the room indicated by a check mark. Uncheck a

load to exclude it from control by this occupancy sensor.

Adjusting Sensor Parameters

Normal Hours/After Hours Settings for Occupancy Sensors

A number of Basic and Advanced load parameters have features that can be set to behave differently

based on the schedule mode of the room. While in Basic or Advanced settings for an Occupancy Sensor,

select the Normal Hours tab to set load parameters for normal hours room mode, or select After Hours to

set load parameters for after hours room mode.

Note: The normal hours/after hours room mode is typically set by a schedule running on the segment man-

ager or by the LMIO-100. To test via LMCS, go to the Advanced Tab for the Room and select either "Set

Normal Hours" or "Set After Hours".

Override the sensor: When the override function is selected, the LCD display will show “OVER”. This set-

ting overrides all sensor functions and bypasses the occupancy control function of the sensor, but still

allows the lights to be manually controlled with a Lighting Management switch, if one is installed.

Time Delay - : The sensor will hold the lights on as long as occupancy is detected. The time delay count-

down starts when no motion is detected. After no motion is detected for the length of the time delay, the

sensor will turn the lights off. You can select between the following time delay options:

Fixed time delay: When a fixed time delay is selected the LCD display will show “T-DELAY” . You can

select a numeric value that ranges from 1 to 30 min using the slider.

Adjusting Sensitivity

For dual technology sensors, both technologies appear on the screen, otherwise the screen only presents

the applicable technology.

Page 71: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 61 of 96

Call 800.879.8585 for Technical Support

Passive Infrared Sensitivity (PIR): 0 to 100% with 10% increments. The LMDC-100 can fine tune its

PIR sensitivity for optimal performance.

Ultrasonic Sensitivity (US): When Ultrasonic sensitivity is selected, the LCD display on the Occupancy

Sensor will show “US” and a numeric value which ranges from 0 to 100% with 10% increments. The

LMDC-100 can fine tune its Ultrasonic sensitivity for optimal performance. In the event the sensitivity is

0%, the sensor won’t transmit any Ultrasound.

Detection Scheme Trigger

Detection Scheme: the LMDC-100 has 16 logic configurations set by the selection of 4 Trigger and 4 Ret-

rigger combinations.

Trigger: When detection trigger is selected, the LCD display on the Occupancy Sensor will show “DETECT

TRIG” and options of technologies (see below for details). This is the method that activates a change from

“standby” (area unoccupied and loads are off) to “occupied” (are occupied and loads are on).

Detection Scheme Retrigger

l Retrigger: When detection retrigger is selected, the LCD display will show “DETECT RETRIG” and

options of technologies (see below for details). This is the method indicating that the area is still

occupied and the lights should remain on.

For each of these methods, the user can select between the following options:

l Passive Infrared Only: requires detection by the PIR

l Ultrasonic: requires detection by the Ultrasonic

l Either Passive Infrared or Ultrasonic: requires detection by only one technology

l Both Passive Infrared and Ultrasonic: requires detection by both technologies

Use Walk Through Mode - : This function can be either enabled or disabled. Walk-through mode turns

the lights off three minutes after the area is initially occupied, if no motion is detected after the first 30

seconds. If motion continues beyond the first 30 seconds, the selected time delay applies. By default Walk

Through mode is disabled.

Page 72: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 62 of 96

www.wattstopper.com16937r1

Personal Controls

Personal Controls include:

Switches

l LMSW-101, 102, 103, 104, 108,

Dimmers

l LMDM-101, LMSW-105

Wall Switch Sensors

l LMPW-101, 102, LMDW-101, 102

The LMSW-10x series are DLM low voltage momentary switches. In a dimming system, you can configure

the buttons on LMSW switches to be either load control or scene control buttons. The switches and dim-

ming switch (dimmer) operate on 24VDC supplied by WattStopper room controllers. They communicate

with other DLM devices over the DLM Local Network.

Scene buttons have valid use cases in non-dimming systems. Scene buttons have implications for day-

lighting that are useful in switched load scenarios.

The LMDM-101 is designed as a dimming switch with a single rocker paddle and seven vertically aligned

LEDs to indicate the relative light level of the load(s) it controls. When it is bound to more than one load

these LEDs show the highest level of any load.

The LMSW-105 is designed specifically for dimming systems. Each of its four small scene buttons recalls

one of four scenes and its rocker paddle is a load dimming switch. The scene buttons can be changed to

load buttons using the LMCS-100 software.

Page 73: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 63 of 96

Call 800.879.8585 for Technical Support

Working with Wall Switches

Click on a switch in the tree view to display the switch settings in the right hand screen frame.

l Device Type – Shows the device type

l Serial Number– Shows the serial number of the device

l Description - Gives a description of the device. Enter a meaningful name into the text box.

l Location - Shows the location of the device

Basic Tab Switch Settings

Currently there are no Basic settings that apply to switches.

Advanced Tab Switch Settings

l Lock Level - options are No Lock, PnG Lock and PnG & PnL Lock

l Serial Number - serial number of the device

l Firmware Version - firmware version of the device

l Hardware Version - hardware version of the device

l Date Code - date code of the device

l On LED Brightness - options are Dim, Medium, High or Low

l Off Led Illuminated - check to enable, uncheck to disable

l Key Lock Mode Enabled - check to enable, uncheck to disable

l Room Profile - currently active room profile for this device

Page 74: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 64 of 96

www.wattstopper.com16937r1

Working with Buttons

Each button on the switch will have a tab under which the settings are grouped. Button settings can be

accessed from the switch page or by clicking on the button under the switch in the expanded tree view.

Description

Button Type - Each button on the switch (except for Rocker buttons) can independently set to perform a dif-

ferent function. Use the pull down list to select the Type for the button.

Basic Load Button Parameters

Button Configuration

Refer to the DLM Dimming System Addendum for further information and system requirements.

Button Configuration enables communication between the load, its assigned switch and the LMCS-100.

Use the Button Configuration function to change Type, Mode and Fade Times of a switch button and to

lock scene buttons.

Based on whether the button pressed is a Scene Button, Load Button or Rocker Button, one of the fol-

lowing screens is presented.

Page 75: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 65 of 96

Call 800.879.8585 for Technical Support

Scene Button Parameters

Button Type - You may change the button type by scrolling through the values for Type. The options are

Scene, network or Load.

Load Type: If you select Load, a new screen appears containing adjustments particular to Load buttons.

Scene Options

Scene Mode - Mode options for Scene buttons are:

l Recall Scene (default). Each time the button is pressed activates the scene.

l Scene Off. Each time the button is pressed deactivates the scene. Note: when Scene Off mode is

set, the blue LED on the button is never lit.

l Recall/OFF. Pressing the button alternately activates the scene or turns OFF the loads associated

with the scene.

Scene Button Properties

Scene Number - The Scene Number contains options for Scene 1 through Scene 16.

Scene Mode - Mode options for Scene buttons are:

l Recall Scene (default). Each time the button is pressed turns ON the scene.

l Scene Off. Each time the button is pressed turns OFF the scene. Note: when Scene Off mode is

set, the blue LED on the button is never lit.

l Recall/OFF is similar to a toggle function, pressing the button once when the scene is not active

recalls the scene; a subsequent button press while the scene is active turns OFF all members of

the scene.

Page 76: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 66 of 96

www.wattstopper.com16937r1

Lock Scene Button - When checked, the button will not allow scene programming changes from this but-

ton.

Lock Button options are Yes and No. Selecting Yes limits the button function to executing the scene per

the Mode setting; light levels for the assigned scene cannot be recorded from this scene button. You can

record the scene light level from this button if Lock Button is No.

Fade Time On, Fade Time Off

Fade Time On and Fade Time Off determine how much time it takes for the loads to reach their target

levels when this button is pressed.

l The fade time defaults are Use Load’s. By default, all loads in a scene carry a two second ON and

OFF fade time. Each button can be set for different fade times independently for the same scene.

Application: This feature allows the user to recall a scene quickly from one button, but from another

button the scene recall is much slower and gradual.

l Fade time value options are from None (immediate) to 18 hours in duration. As you scroll through

the values, the units of measure change from seconds to minutes to hours.

Load Button Parameters

Type - You may change the button type by scrolling through the values for Type. The options are Scene,

Network or Load. If you select Scene 1 through 16 a new screen appears containing adjustments particular

to Scene buttons (see Scene Button Parameters).

Controlled Loads

Load buttons by default are assigned to control loads based on Plug and Go settings during initial start up

of the room devices.

l Place a check by the load to have this button control the load.

l Place a check by the Include Plug Loads to include Plug Loads.

Page 77: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 67 of 96

Call 800.879.8585 for Technical Support

Mode- Mode options for Load buttons are Toggle (default), On Only and Off Only.

l In On Only or Off Only mode, each button press only causes the associated action.

l In Toggle mode, if there are multiple loads bound to a button and any load is ON, the LED will be

lit. Pressing the button turns OFF all loads and the LED on the button turns OFF. Pressing the but-

ton again turns ON all loads bound to the button.

Fade On, Fade Off- Fade On and Fade Off determine the time that it takes for loads bound to this button

to reach the target level.

l The fade time defaults are Use Load’s. By default, all loads carry a two second ON and OFF fade

time. Each button can be set for different fade times independently for the same loads, allowing

fast or slow load fade, depending on the button pressed.

l Fade time value options are from None (immediate) to 18 hours in duration.

Advanced Load Button Parameters

l Button Preset Value On - check the Use Last Level check box to keep the preset value. This is the

level that a load will go to when it receives an ON command from this button. Uncheck the Use Last

Level check box to turn the preset value off. Use the slider to enter a new value, or type it into the

text box.

l Button Preset Value Off - check the Relinquish check box to keep the preset value. This is the level

that a load will go to when it receives an OFF command from this button. Uncheck the Relinquish

Page 78: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 68 of 96

www.wattstopper.com16937r1

check box to turn the preset value off. Use the slider to enter a new value, or type it into the text

box.

l Button Override Time Until Off - check the Override Time Until Off check box to keep the preset

value. Uncheck the Override Time Until Off check box to turn the preset value off. Use the slider to

enter a new value, or type it into the text box.

Rocker Button Parameters

Rocker button, or paddle, is a type of load button. It cannot be changed to be a scene button. Parameter

options are Fade On, Fade Off, and Ramp Rate.

Mode- Mode options for Rocker buttons are Toggle (default), On Only and Off Only.

Fade Mode choices are:

l Immediate

l Use Fade Rate- This is the rate that target loads will use to get to the target level when the user

taps on the button. If a time is set here, then all assigned loads will use this fade time when fading

up.

l Button Fade Rate- When you choose the Use Fade Rate option, you can use the slider to enter a

new value, or type it into the Button Fade Rate text box.

l User Fade Time - This is the Fade Time associated with the press of a regular button when the ON

action is performed.

l Button Fade Time ON - Check 'Use Load Fade Time' to use the defaults. When you uncheck the

Use Fade Time On option, you can use the slider to enter a new value, or type it into the Button

Fade Time On text box.

l Button Fade Time OFF - Check 'Use Load Fade Time' to use the defaults. When you uncheck the

Use Fade Time On option, you can use the slider to enter a new value, or type it into the Button

Fade Time On text box.

Button Fade Time On, Fade Time Off

Fade Time On and Fade Time Off determine how much time it takes for the loads bound to this rocker to

reach their target levels when this button is pressed.

l The fade time defaults are Use Load’s. By default, all loads in a scene carry a two second ON and

OFF fade time. Each button can be set for different fade times independently for the same scene.

Page 79: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 69 of 96

Call 800.879.8585 for Technical Support

Application: This feature allows the user to recall a scene quickly from one button, but from another

button the scene recall is much slower and gradual.

l Fade time value options are from None (immediate) to 18 hours in duration. As you scroll through

the values, the units of measure change from seconds to minutes to hours.

Rocker Button Properties

The fade time defaults are Use Load’s. By default, all loads carry a two second ON and OFF fade time.

Each rocker and button can be set for a different fade time independently for the same loads, allowing fast

or slow load fade depending on the button or rocker used.

Fade time value options are from None (immediate) to 18 hours in duration. As you scroll through the val-

ues, the units of measure change from seconds to minutes to hours.

Rocker Button Parameters Only

Advanced Tab Rocker Button Parameters

l Ramp Rate - determines the speed (or rate) at which the light level of bound loads increases or

decreases when the top or bottom of the rocker is pressed and held. The default value is

17%/second which means that it takes approximately 6 seconds to ramp from 0-100%.

Network Button Properties

The Network Button Properties are viewable in the LMCS, however they should not be edited. Network

Groups are used by the Segment Manager and have the ability to control light levels throughout the facil-

ity.

l Group ID - The Network Group ID used by the Segment Manager.

l Momentary Mode - Options to control Only On, Only Off, or Toggle. Toggle Non-tracking is a spe-

cial case where the LED does not follow button presses. The LED instead follows the state emitted

by the Segment Manager.

Page 80: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 70 of 96

www.wattstopper.com16937r1

Dimmers

Dimmers include:

l LMDM-101, LMSW-105 models

The LMDM-101 is designed as a dimming switch with a single rocker paddle and seven vertically aligned

LEDs to indicate the relative light level of the load(s) it controls. When it is bound to more than one load

these LEDs show the highest level of any load.

Refer to Working with the LMDM-101 Rocker Paddle

The LMSW-105 is designed specifically for dimming systems. Each of its four small scene buttons recalls

one of four scenes and its rocker paddle is a load dimming switch. The scene buttons can be changed to

load buttons using the LMCS-100 software.

Working with the LMSW-105 Scene Switch

The LMSW-105 Digital Scene Switch is a low voltage device used to set and recall preset lighting scenes

and raise and lower lighting levels. This device combines the features of a four button scene switch and a

rocker paddle dimmer (LMDM-101).

Click on the scene switch icon in the tree view to display its settings in the right hand screen frame

l Device Type – Shows the device type

l Serial Number– Shows the serial number of the device

l Description - Gives a description of the device. Enter a meaningful name into the text box.

l Location - Shows the location of the device

Basic Tab Settings for the Scene Switch

There are no basic settings for the scene switch at this time.

Page 81: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 71 of 96

Call 800.879.8585 for Technical Support

Advanced Tab Settings for the Scene Switch

l Lock Level - No Lock, PnG Lock or PnG & PnG Lock

l Serial Number - Changing the serial number of a device can have destructive results.

l Click on the Advanced button to change the device serial number. See Advanced Device Info box below.

l Firmware Version

l Hardware Version

l Date Code

l On LED Brightness

l Off LED Illuminated

l Key Lock Mode Enabled

l Room Profile

Advanced Device Info Dialog

Warning: Changing made here can cause system malfunction. Only make changes here if directed by

WattStopper Engineering. Changing the serial number of a device can have destructive results.

LMSW-105 Scene Switch

The LMSW-105 scene switch has both buttons and a rocker switch. The settings for each are found under

the corresponding tab.

Page 82: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 72 of 96

www.wattstopper.com16937r1

l Description - Rocker 1 or Button #

l Button Type - Button type for a Rocker cannot be changed. A button can be changed to either a

Scene, Network or Load button.

Controlled Loads

By default the Plug and Go installation process binds all loads in the room to the rocker switch. The bind-

ing is indicated by the check mark beside the load. To remove a load from control of the rocker, uncheck

the check mark box beside the load.

Page 83: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 73 of 96

Call 800.879.8585 for Technical Support

Basic Rocker Button Properties

Button Fade Time On, Button Fade Time Off

l Fade On and Fade Off determines the time that it takes for loads bound to this rocker to reach the

target level.

l The fade time defaults are Use Load’s. By default, all loads carry a two second ON and OFF fade

time. Each rocker and button can be set for a different fade time independently for the same loads,

allowing fast or slow load fade depending on the button or rocker used.

l Fade time value options are from None (immediate) to 18 hours in duration. As you scroll through

the values, the units of measure change from seconds to minutes to hours.

Advanced Rocker Button Properties

l Button Preset Value On - Set the preset value to on

l Button Preset Value Off- Set the preset value to on

l Button Override Time Until Off - Sets the Override Time Off value

l Button Ramp Rate - determines the speed (or rate) at which the light level of bound loads increases

or decreases when the top or bottom of the rocker is pressed and held. The default value is

17%/second which means that it takes approximately 6 seconds to ramp from 0-100%.

Page 84: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 74 of 96

www.wattstopper.com16937r1

Working with Buttons on a Scene Switch

The settings for each button on the scene switch are available under tabs. By default these are Scene

type buttons.

Scene Button Properties

l Scene Number

l Scene Mode

l Lock Scene Button

l Fade Time On

l Fade Time Off

Editing a Scene

Click on the Edit button next to the scene number to open the Scene Editor Dialog Box.

Page 85: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 75 of 96

Call 800.879.8585 for Technical Support

Use the sliders to adjust the light level and the fade time for each load in the scene. If LMCS is connected

to the room, the lights will dim when the Target Level slider is adjusted. It is necessary to click the send

button after adjusting scenes if you wish to make the changes in the room devices.

Page 86: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 76 of 96

www.wattstopper.com16937r1

Working with Daylighting Sensors

Using Current Settings, you can view all parameters applicable to the type of sensor that is currently com-

municating with the LMCS-100. You can modify settings, send them to the sensor, and/or store them for

later retrieval. Clicking on an occupancy sensor in the tree will open that device for editing in the right hand

screen frame.

Daylight Sensor Models:

l LMLS-400, LMLS-500;

l LMLS-600; Limited support provided for this device.

Working With LMLS-400 Daylight Sensors

Click on a daylight sensor in the tree view to display its settings in the right hand screen frame.

l Device Type – Shows the device type

l Serial Number– Shows the serial number of the device

l Description - Gives a description of the device. Enter a meaningful name into the text box.

l Location- Shows the location of the device

Basic Tab Settings for LMLS-400 Daylight Sensor

l Number of Zones

l Light Level at Sensor

Page 87: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 77 of 96

Call 800.879.8585 for Technical Support

Auto Calibrate

Calibration establishes a relationship between the workplane illuminance and the light level measured by

the sensor.

Click the Auto Calibrate button to start the calibration process. Note: this feature applies to the LMLS-400 daylight sensor only.

Advanced Tab Settings for LMLS-400 Daylight Sensors

l Lock Level

l Serial Number

l Firmware Version

l Hardware Version

l Date Code

Control Mode - Control Mode is used to set the control behavior of the photosensor. The current control

mode is displayed in the text box. This can be changed to Normal, Test, Demo, or Disable using the pull-

down menu.

l Normal mode allows the photosensor to take control of the daylighting loads.

l Test Mode shortens timeouts for switching operation, and speeds ramp rates for dimming oper-

ation, to allow quick verification. Test Mode cancels automatically after 5 minutes.

l Demo mode will allow the photosensor to select a set of preset parameters. This mode should only

be selected when demonstrating the functionality of the unit is desired.

l Disable mode prevents the LMLS-400 from controlling any daylighting loads. This parameter is

mostly used for troubleshooting purposes.

Override Timeout - If the Override Time parameter is changed from its default (Infinity) to a fixed time

(e.g., 1 hour), all loads presently overridden will return to automatic daylighting control after the selected

time period lapses. Any loads not affected by the switch actions causing the override will continue to be

controlled by daylighting; overrides occur on a load-by-load basis. If any daylighting loads are presently

overridden, the blue LED in the sensor head will flash once every four seconds. To provide the ability to set

Page 88: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 78 of 96

www.wattstopper.com16937r1

arbitrary light levels in Dimmed applications, a switch with a dimming control rocker (e.g., LMDM-101 or

LMSW-105) should be used.

l Minimum Time to Update

l Minimum Change of Value to Update

Hold Off - The Hold Off setting selects the behavior of daylighting loads when they are turned ON, by a

switch or occupancy sensor.

If Hold Off = <No> (default), the loads can always be turned on to their previous level, and then will begin

to adjust based upon daylight. If Hold Off is checked (Yes), the sensor will limit the loads to the level

presently allowed by daylight contribution. This means that the loads may not initially turn ON (if the ambi-

ent light level is high - above the ON or Dimming Setpoint), but will become active for daylighting control,

and will turn ON or dim up as daylight contribution drops.”

Override Allowed - Determines if overriding the photosensor is permitted or not. Available choices:

Checked (Yes) or unchecked (No).

Scenes Disable Daylighting - When unchecked (set to No), the sensor allows daylighting to adjust

light levels, up to the level recorded in the Scene, even though a scene is active. When checked (set to

Yes), daylighting control is disabled for any loads on which a scene is recalled until a change is manu-

ally made to the level of a load in the zone, or until the next cycle of occupancy.

Follow After Hours - When the checkbox is selected, the photosensor will ignore After Hours and will con-

tinue to operate as normal. When deselected (set to No), the daylighting controlled loads that are set to

After Hours mode will be temporarily be removed from daylighting control while in the After Hours state.

Working with Controlled Loads

The LMLS-400 has the capability to operate using continuous dimming, stepped dimming or simple switch-

ing. Use the check boxes to select the loads for control appropriate to the type of operation mode selected.

Page 89: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 79 of 96

Call 800.879.8585 for Technical Support

Operation Mode: Switched, Bi Level, Tri Level or Dimming

Once an operating mode is selected, you will need to assign specific loads to daylighting control. Load

assignment is analogous to binding.

On Setpoint - The target illuminance level at the sensor, below which the LMLS-400 turns the lights ON.

l The ON Setpoint values available for manual adjustment are: 1.0- 3000 footcandles; note that cal-

ibration can automatically select a value not in this list.

l Established by calibration, or selected footcandle setting (Default: 7.5 fc)

l Target illuminance measured at the sensor below which daylighting loads will turn ON.

Off Setpoint - The target illuminance level at the sensor, above which the LMLS-400 turns the lights OFF.

Page 90: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 80 of 96

www.wattstopper.com16937r1

l The OFF Setpoint corresponds to the ON Setpoint multiplied by 1.25, 1.50, 1.75 or 2.0. This

ensures that the OFF Setpoint is always higher than the On Setpoint.

l Established by calibration, or selected footcandle setting (Default: 11 fc)

l Target illuminance measured at the sensor below which daylighting loads will turn OFF.

On Setpoint Delay - The time interval that must elapse, with the measured level below the ON Setpoint,

before the controlled lights turn on.

l Range: 1 sec to 60 sec.

Off Setpoint Delay - The time interval that must elapse, with the measured level above the OFF Set-

point, before the controlled lights turn OFF.

l Range: 3 min to 30 min.

Operation Mode - Dimming

Day Setpoint - The desired light level at the sensor during daytime. To determine the correct dimming

level for any given photocell reading, it calculates the level based on the slope between the day and the

night setpoint.

l Range: 1 fc to 255 fc.

Night Setpoint- The desired light level at the sensor during nighttime. To determine the correct dimming

level for any given photocell reading, it calculates the level based on the slope between the day and the

night setpoint.

Page 91: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 81 of 96

Call 800.879.8585 for Technical Support

l Range: 1 fc to 255 fc.

Note: The Day Setpoint must always be greater than the Night Setpoint.

Ramp Up Rate- Determines the speed (or rate) at which the light level of bound loads increases. The

default is 20% per second because the end user needs light quickly.

Range: 1% per second to 100% per second.

Ramp Down Rate- Determines the speed (or rate) at which the light level of bound loads decreases. The

default is 2% per second because a slow ramp down will help the eye adapt to the new light level.

l Range: 1% per second to 100% per second.

Cut Off Delay - The time that the controlled lighting will remain at a minimum dimmed level, even with

high daylight contribution, before the lights will be switched OFF.

l Range: Never to 30 min.

Advanced Settings for LMLS-400

Advanced Settings allows you to see the light level at the photocell, adjust the override mode, the override

time delay, hold off, scene switch and after hours' interaction.

l Electric Light - Present light level measured at the LMLS-400.

l Electric Light Ratio

l Day Setpoint

l Electric Light Setpoint Multiplier

Working with LMLS-500 Daylight Sensors

Page 92: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 82 of 96

www.wattstopper.com16937r1

Click on the LMLS-500 sensor in the tree view to display its settings in the right hand screen frame

l Device Type – Shows the device type

l Serial Number– Shows the serial number of the device

l Description - Gives a description of the device. Enter a meaningful name into the text box.

l Location- Shows the location of the device

Basic Tab Settings for LMLS-500 Daylight Sensor

Zone Setup allows you to select the number of zones, change the operation mode of a zone, specify if a

selected load is to be controlled by Daylighting and to bind loads to the LMLS-500.

Number of Zones

Light Level at Sensor

Advanced Tab Settings for LMLS-500 Daylight Sensors

Advanced Settings is used to set the light level at the photocell and to adjust the override mode and the

override time delay.

Lock Level

Serial Number

Firmware Version

Page 93: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 83 of 96

Call 800.879.8585 for Technical Support

Hardware Version

Date Code

Control Mode - Control Mode allows you to select the control status of the photosensor. After choosing

Control Mode, the current control mode is displayed. This can be changed to Normal, Test, Demo, or Dis-

able.

Normal Mode allows the photosensor to take control of the daylighting loads.

Test Mode shortens timeouts for switching operation, and speeds ramp rates for dimming operation, to

allow quick verification. Test Mode cancels automatically after 5 minutes.

Demo Mode will allow the photosensor to select a set of preset parameters. This mode should only be

selected when demonstrating the functionality of the unit is desired.

Disable Mode allows you to deactivate the LMLS-500 from the system. This parameter is mostly used for

troubleshooting purposes.

Override Timeout - Override Time selects the time delay, after daylighting control has been disabled due

to an observed external user or system action, before automatic control resumes.

l Range: Infinity or 1 to 24 hours.

Minimum Time to Update

Minimum Change of Value to Update

Hold Off - The Hold Off setting selects the behavior of daylighting loads when they are turned ON, by a

switch or occupancy sensor.

l If Hold Off = <No> (default), the loads can always be turned on to their previous level, and then will

begin to adjust based upon daylight.

l If Hold Off = <Yes>, the sensor will limit the loads to the level presently allowed by daylight con-

tribution. This means that the loads may not initially turn ON (if the ambient light level is high -

above the ON or Dimming Setpoint), but will become active for daylighting control.

Override Allowed- Determines if override mode is permited, while daylighting control is active.

l Available choices: Yes or No

Scenes Disable Daylighting - When set to No the sensor adjusts levels, up to that recorded in the

scene, even though a scene is active. When set to Yes, daylighting control is disabled for any loads on

Page 94: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 84 of 96

www.wattstopper.com16937r1

which a scene is recalled until a change is manually made to the level of the load, or until the next cycle of

occupancy.

Follow After Hours- When set to Yes, the photosensor will ignore After Hours and will continue to oper-

ate as normal.

When set to No, the daylighting controlled loads that are set to After Hours are removed from daylighting

control for the duration of the After Hours period.

Working with Controlled Loads

The LMLS-500 has the capability to operate using continuous dimming, stepped dimming or simple switch-

ing. Use the check boxes to select the loads for control appropriate to the type of operation mode selected.

After choosing the number of zones , the current operation mode is displayed. This can be changed to

Switched, Bi-Level, Tri-Level, or Dimmed.

Operation Mode: Switched, Bi Level or Tri Level

Page 95: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 85 of 96

Call 800.879.8585 for Technical Support

On Setpoint - The target illuminance level below which the LMLS-500 turns the lights ON.

l Range: 5 to 150 fc.

Off Setpoint - The target illuminance level above which the LMLS-500 turns the lights OFF.

l The OFF Setpoint corresponds to the ON Setpoint multiplied by 1.25, 1.50, 1.75 or 2.0. This

ensures that the OFF Setpoint is always higher than the ON Setpoint.

On Setpoint Delay - The time interval that must elapse, with the measured level below the ON Setpoint,

before the controlled lights turn ON.

l Range: 1 sec to 60 sec.

Off Setpoint Delay - The time interval that must elapse, with the measured level above the OFF Set-

point, before the controlled lights turn OFF.

l Range: 3 min to 30 min.

Operation Mode - Dimming

Dimmed mode provides continuous dimming within the daylight zone controlled by the photosensor.

Day Setpoint- The desired light level at the task per zone. To determine the correct dimming level for any

given photocell reading, it calculates the level based on the slope between the daylight contribution at the

sensor and the setpoint.

l Range: 5 to 200 fc.

Page 96: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 86 of 96

www.wattstopper.com16937r1

Night Setpoint- The desired light level at the task per zone. To determine the correct dimming level for

any given photocell reading, it calculates the level based on the slope between the daylight contribution at

the sensor and the setpoint.

l Range: 5 to 200 fc.

Ramp Up Rate - Determines the speed (or rate) at which the light level of bound loads increases. The

default is 20% per second because the end user needs light quickly.

l Range: 1% per second to 100% per second.

Ramp Down Rate- Determines the speed (or rate) at which the light level of bound loads decreases. The

default is 2% per second because a slow ramp down will help the eye adapt to the new light level.

l Range: 1% per second to 100% per second.

Cut Off Delay- The time that the controlled lighting will remain at a minimum dimmed level, even with

high daylight contribution, before the lights will be switched OFF.

l Range: Never to 30 min.

Advanced Settings for LMLS-500

Electric Light - Electric Light is the measured artificial light contribution per zone. Present light level

measured at the LMLS-500.

Daylight Ratio Workplane - DR = Daylight Ratio is the relationship between the daylight measured at

the photocell versus the daylight per zone.

Daylight Ratio Sensor -

Electric Light Setpoint Multiplier -

Page 97: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 87 of 96

Call 800.879.8585 for Technical Support

Working With LMLS-600 Daylight Sensors

Click on a daylight sensor in the tree view to display its settings in the right hand screen frame.

l Device Type – Shows the device type

l Serial Number– Shows the serial number of the device

l Description - Gives a description of the device. Enter a meaningful name into the text box.

l Location- Shows the location of the device

Basic Tab Settings for LMLS-600 Daylight Sensor

l Number of Zones - There is only 1 zone and therefore not selectable

l Down Light Sensor - Gives the present light level measured at the down looking photodiode. Down

looking range: 0 to 65 fc

l Up Light Sensor - Gives the present light level measured at the up looking photodiode. Up looking

range: 0 to 6500 fc

l Internal Status

l Maximum Electric Light (A+B)

l Maximum Electric Light B Percent

l Daylight Ratio - Shows the latest average ratio between the daylight contribution seen in the

closed-loop (down-looking) sensor and that measured by the open-loop (up-looking) sensor.

Auto Calibrate

Calibration establishes a relationship between the workplane illuminance and the light level measured by

the sensor.

Click the Auto Calibrate button to start the calibration process. Note: this feature applies to the LMLS-400 or LMLS-600 daylight sensor only.

Page 98: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 88 of 96

www.wattstopper.com16937r1

Recommission

Recommission establishes a relationship between the workplane illuminance and the light level measured

by the sensor.

Click the Recommission button to start the recommission process. Note: this feature applies to the LMLS-600 daylight sensor only.

Advanced Tab Settings for LMLS-600 Daylight Sensors

l Lock Level

l Serial Number

l Firmware Version

l Hardware Version

l Date Code

Control Mode - Control Mode is used to set the control behavior of the photosensor. The current control

mode is displayed in the text box. This can be changed to Normal, Test, Demo, or Disable using the pull-

down menu.

l Normal mode allows the photosensor to take control of the daylighting loads.

l Test Mode shortens timeouts for switching operation, and speeds ramp rates for dimming oper-

ation, to allow quick verification. Test Mode cancels automatically after 5 minutes.

l Demo mode will allow the photosensor to select a set of preset parameters. This mode should only

be selected when demonstrating the functionality of the unit is desired.

l Disable mode prevents the LMLS-600 from controlling any daylighting loads. This parameter is

mostly used for troubleshooting purposes.

Override Timeout - If the Override Time parameter is changed from its default (Infinity) to a fixed time

(e.g., 1 hour), all loads presently overridden will return to automatic daylighting control after the selected

time period lapses. Any loads not affected by the switch actions causing the override will continue to be

controlled by daylighting; overrides occur on a load-by-load basis. If any daylighting loads are presently

Page 99: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 89 of 96

Call 800.879.8585 for Technical Support

overridden, the blue LED in the sensor head will flash once every four seconds. To provide the ability to set

arbitrary light levels in Dimmed applications, a switch with a dimming control rocker (e.g., LMDM-101 or

LMSW-105) should be used.

Minimum Time to Update

Minimum Change of Value to Update

Hold Off - The Hold Off setting selects the behavior of daylighting loads when they are turned ON, by a

switch or occupancy sensor.

If Hold Off = <No> (default), the loads can always be turned on to their previous level, and then will begin

to adjust based upon daylight. If Hold Off is checked (Yes), the sensor will limit the loads to the level

presently allowed by daylight contribution. This means that the loads may not initially turn ON (if the ambi-

ent light level is high - above the ON or Dimming Setpoint), but will become active for daylighting control,

and will turn ON or dim up as daylight contribution drops.”

Override Allowed - Determines if overriding the photosensor is permitted or not. Available choices:

Checked (Yes) or unchecked (No).

Scenes Disable Daylighting - When unchecked (set to No), the sensor allows daylighting to adjust

light levels, up to the level recorded in the Scene, even though a scene is active. When checked (set to

Yes), daylighting control is disabled for any loads on which a scene is recalled until a change is manu-

ally made to the level of a load in the zone, or until the next cycle of occupancy.

Follow After Hours - When the checkbox is selected, the photosensor will ignore After Hours and will con-

tinue to operate as normal. When deselected (set to No), the daylighting controlled loads that are set to

After Hours mode will be temporarily be removed from daylighting control while in the After Hours state.

LMLS-600 Tab Settings for LMLS-600 Daylight Sensors

The LMLS-600 tab is used to adjust On Setpoint Electric Light, Recommissioning Threshold, Recom-

misioning Time Deleay, Diagnostic Error Flags, Force Open-Loop Control, Recommissioning Time Delay,

Diagnostic Error Flags

Page 100: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 90 of 96

www.wattstopper.com16937r1

l Secondary Sensor Minimum Time to Update -

l Secondary Sensor Minimum Change of Value to Update

l Dimming Setpoint Electric Light Percent Adder

l On Setpoint Electric Light

l Recommissioning Threshold

l Recommisioning Time Delay

l Diagnostic Error Flags

l Force Open-Loop Control

Working with Controlled Loads

The LMLS-600 has the capability to operate using continuous dimming, stepped dimming or simple switch-

ing. Use the check boxes to select the loads for control appropriate to the type of operation mode selected.

The Operation Mode pull-down menu offers the following : Switched , Bi-level,Tri-level or Dimming

l Switched - Switched mode provides ON/OFF switching within the daylighting zone controlled by

the photosensor.

l Bi-level - Bi-level mode provides three light levels within the daylighting zone controlled by the pho-

tosensor by using 2 load circuits.

l Tri-level - Tri-level mode provides four light levels within the daylighting zone controlled by the pho-

tosensor by using 2 load circuits.

Page 101: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 91 of 96

Call 800.879.8585 for Technical Support

l Dimming - Dimming mode provides continuous dimming within the daylight zone controlled by

the photosensor.

Once an operating mode is selected, you will need to assign specific loads to daylighting control. Load

assignment is analogous to binding.

On Setpoint - The On Setpoint values available for manual adjustment are: 1.0- 3000 footcandles; note

that calibration can automatically select a value not in this list.

l Established by calibration, or selected footcandle setting (Default: 7.5 fc)

l Target illuminance measured at the sensor below which daylighting loads will turn ON.

Off Setpoint - The target illuminance level at the sensor, above which the LMLS-400 turns the lights OFF.

The OFF Setpoint corresponds to the ON Setpoint multiplied by 1.25, 1.50, 1.75 or 2.0. This ensures that

the OFF Setpoint is always higher than the On Setpoint.

l Established by calibration, or selected footcandle setting (Default: 11 fc)

l Target illuminance measured at the sensor below which daylighting loads will turn OFF.

On Setpoint Delay - The time interval that must elapse, with the measured level below the ON Setpoint,

before the controlled lights turn on.

l Range: 1 sec to 60 sec.

Page 102: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 92 of 96

www.wattstopper.com16937r1

Off Setpoint Delay - The time interval that must elapse, with the measured level above the OFF Set-

point, before the controlled lights turn OFF.

l Range: 3 min to 30 min.

Operation Mode - Dimming

DimmingSetpoint - The desired light level to be maintained by daylighting control, as measured at the

down looking sensor. When the present measured light level differs from this setpoint by more than approx-

imately 7%, the sensor will attempt to adjust the electric lighting to compensate.

l Range: 0 to 65 fc

Ramp Up Rate- Determines the speed (or rate) at which the light level of bound loads increases. The

default is 20% per second because the end user needs light quickly.

l Range: 1% per second to 100% per second.

Ramp Down Rate- Determines the speed (or rate) at which the light level of bound loads decreases. The

default is 2% per second because a slow ramp down will help the eye adapt to the new light level.

l Range: 1% per second to 100% per second.

Cut Off Delay - The time that the controlled lighting will remain at a minimum dimmed level, even with

high daylight contribution, before the lights will be switched OFF.

l Range: Never to 30 min.

Page 103: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Adjusting Device Parameters

Page 93 of 96

Call 800.879.8585 for Technical Support

Other Supported Devices

Switches

l LMIO-101 (Digital Input/Output Interface). This can be accessed by clicking Add Devices -

Switches - LMIO-101.

Daylighting

l LMIO-301 (Digital Photocell Input Module); This can be access by clicking Add Devices under day-

lighting.

Network Bridge

l LMBC-300 )Digital Network Bridge)

Note: The LMBC-300 is not Boot-Loadable by LMCS over IRB due to device design.

WARNING: Changing the serial number on the LMBC-300 Network Bridge causes the device to

be reset to factory defaults including the BACnet communication properties. Changing the BACnet

properties can cause the bridge to loose communication with the BACnet network. If a bridge is

being replaced in the field and the serial number must be changed to match the previous bridge

then the original properties should be transferred into the new bridge as soon as possible.

See device installation and LMCT-100 instructions for information on function of parameters on above

devices.

Page 104: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 94 of 96

www.wattstopper.com16937r1

Appendix A – Devices Supported by LMCS-100 4.2Room Controllers

Small Room Controllers

l LMRC-101 Single Relay Room Controller

l LMRC-102 Dual Relay Room Controller

Enhanced Room Controllers

l LMRC-211 (One Relay Room Controller with 0-10v Dimming)

l LMRC-212 (Two Relay Room Controller with 0-10v Dimming)

l LMRC-213 (Three Relay Room Controller with 0-10v Dimming)

l LMRC-221 (One Relay Room Controller with Phase Dimming)

l LMRC-222 (Two Relay Room Controller with Phase Dimming)

Plug load controllers

l LMPL-101 (Digital Plug Load Room Controller)

l LMPL-201 (Digital Plug Load Controller with Current Monitoring)

All Room Controllers at version 5.11

Occupancy Sensors

l LMDC-100 (Digital Dual Technology Ceiling Mount Occupancy Sensor)

l LMPC-100 (Digital PIR Ceiling Mount Occupancy Sensor)

l LMUC-100 (Digital Ultrasonic Ceiling Mount Occupancy Sensor)

l LMDX-100 (Digital Dual Technology Corner Mount Occupancy Sensor)

l LMPX-100 (Digital PIR Corner Mount Occupancy Sensor)

l LMUC-200 (Digital Ultrasonic Ceiling Mount Occupancy Sensor)

Page 105: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

Appendix A – Devices Supported by LMCS-100 4.2

Page 95 of 96

Call 800.879.8585 for Technical Support

Personal Controls

Switches

l LMSW-101 (1-Button Digital Wall Switch

l LMSW-102 (2-Button Digital Wall Switch

l LMSW-103 (3-Button Digital Wall Switch

l LMSW-104 (4-Button Digital Wall Switch

l LMSW-108 (8-Button Digital Wall Switch

l LMIO-101 (Digital Input/Output Interface)

Dimmers

l LMDM-101 (Digital Dimming Wall Switch)

l LMSW-105 (5-Button Digital Scene Switch)

Wall switch sensors

l LMDW-101 (1-Button Digital Dual Tech Wall Switch Occupancy Sensor)

l LMDW-102 (2-Button Digital Dual Tech Wall Switch Occupancy Sensor)

l LMPW-101 (1-Button Digital PIR Wall Switch Occupancy Sensor)

l LMPW-102 (2-Button Digital PIR Wall Switch Occupancy Sensor)

Daylighting

l LMLS-400 (Single Zone Switching and Dimming Closed Loop Digital Photosensor)

l LMLS-500 (Multi-zone Switching and Dimming Open Loop Digital Photosensor)

l LMLS-600 (Single zone Switching and Dimming Dual-Loop Digital Photosensor)

l LMIO-301 (Digital Photocell Input Module)

Network Bridge

l LMBC-300 (Digital Network Bridge)

Page 106: LMCS-100 Lighting Management...User Interface 10 Navigating 10 The Home Tab 10 The Support Tab 12 The Help Tab 12 Project Explorer 12 Navigation Tree 13 Window Frames 13 Reports 15

LMCS-100 Configuration Software User Guide

Page 96 of 96

www.wattstopper.com16937r1

Appendix B – Devices NOT Supported by LMCS-100 4.2

l LMLS-105

l LMLS-305

l LMCT

l LMSM

l LILM Panels

l LMRC-311, 312, 313

l LMRH-101, 102, 105

l LMRL-100

Note : The LMRC-3xx series devices are being discontinued. In LMCS 4.2, the LMRC-3xx series

devices will be visualized as two separate devices, the appropriate LMRC-2xx equivalent device plus an

LMBC-300 bridge device.