Your Advantages : Remote ; Reset, Monitoring, on/off functionality 90% Load limit warning to aid implementation of preventative maintenance strategies Integrated test points in the IO-channels of the control current distribution Practical disconnecting lever for galvanic isolation of the load circuit for testing purposes Cross connections between load monitoring and potential distribution terminals Approvals for Marine, Class 2 and EX-areas Using WMC Configuration Software simplifies system design maxGUARD provides reliable & fast acting protection for 24Vdc circuits compared to traditional breakers and with a combination of load monitoring and potential distribution reduces the amount of space required on the terminal rail by 50 %, whilst also saving time during installation. Load protection and potential distribution combined maxGUARD – taking control voltage distribution to a new level

Upload: others

Post on 22-Feb-2022

8 views

Category:

Documents


0 download

TRANSCRIPT

Your Advantages :

• Remote ; Reset, Monitoring, on/off functionality

• 90% Load limit warning to aid implementation of preventative maintenance strategies

• Integrated test points in the IO-channels of the control current distribution

• Practical disconnecting lever for galvanic isolation of the load circuit for testing purposes

• Cross connections between load monitoring and potential distribution terminals

• Approvals for Marine, Class 2 and EX-areas

• Using WMC Configuration Software simplifies system design

maxGUARD provides reliable & fast acting protection for 24Vdc circuitscompared to traditional breakers and with a combination of load monitoringand potential distribution reduces the amount of space required on theterminal rail by 50 %, whilst also saving time during installation.

Load protection and potential distribution combinedmaxGUARD – taking control voltage distribution to a new level

Assembly Principles 3 main cross connection channels for plus,

minus and internal signaling. Cross connection possible from the outputs (plus

and minus) of the electronic monitoring device into the terminal blocks for duplication of the connections.

Electronic load monitoring devices and terminal blocks can be combined to complete 24V DC distribution boards with all necessary connection for the loads.

+

6,1mm

Electronic load monitoring

cross connection: backbone plus 40A

cross connection: backbone minus 40A

Internal signaling

output : plus

output: minus

Terminal block

Load protection and potential distribution combinedmaxGUARD – taking control voltage distribution to a new level