lorem ipsum loremsasdt.co.za/wp-content/uploads/2018/05/6_1-cp_dthozee... · 2019. 2. 8. ·...

29
South African Society of Dairy Technology Symposium 24-26/04

Upload: others

Post on 19-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • Lorem Ipsum Lorem

    South African Society of Dairy Technology Symposium 24-26/04

  • UNISENSOR

    Unisensor is a Belgian company researching,

    developing and manufacturing diagnostic tools for the detection of contaminants present in

    food products.

  • EU RESEARCH PROGRAMS

    2015

    “ GOOD FOOD ”

    “ CONFFIDENCE ”

    CompanyTimeline milestones

    2005

    Twinsensor

    PATENTED

    CONCEPT

    page014

    BEADYPLEX

    R&D EFFORT

    EXTENSO

    2017

    REVOLUTIONARY MILK ANALYSISPLATFORM

  • MULTIPLE: + 100 molecules in a single testDetection level at EU MRL

    X1

    7

  • Our Product Development StrategyIn two words…

    page05

    Multiple tests in one (antibiotics)• Reliable & Usable everywhere• Rapid & Cost-effective• Validated by external parties

    MULTIPLEXING + CONTAMINANTS1 x

    17 x

  • page07

    BEADYPLEXScheme of analytical methods for antibiotic residues analysis

    Confirmation

    Screening

    IMMUNOAssaysStructureELISA

    LFIA

    LC-MSPHYSICOCHEMICAL

    Composition

    TESTINGPRINCIPLES

    METHODSAVAILABLE

    MICROBIOLOGICALActivity Inhibition

    Complexity

    Price

    http://www.google.be/url?sa=i&rct=j&q=LC-MS&source=images&cd=&cad=rja&docid=I5fRxKItkFXBKM&tbnid=o_3ewSAWT9cT_M:&ved=0CAUQjRw&url=http://www.agilent.com/about/newsroom/lsca/imagelibrary/index_2003.html&ei=EbhmUca3G6OP0AXO-oGYCw&bvm=bv.45107431,d.d2k&psig=AFQjCNEuYLOCq2kxkQ_vbnYZuj2TSqWZCg&ust=1365772686067446http://www.google.be/url?sa=i&rct=j&q=lateral+flow+chromatography&source=images&cd=&cad=rja&docid=o8IBVpS_pYmSoM&tbnid=QEPoAWNDCq_ArM:&ved=0CAUQjRw&url=http://www.biomerica.com/products/product_detail.asp?ProductID=70&ei=ALpmUeTBLuPE0QW7lYHgDQ&bvm=bv.45107431,d.d2k&psig=AFQjCNEWrUI3l9wh1Zae0iNBkGKW0DtpYA&ust=1365773108280158

  • page08

    BEADYPLEXUnmet needs for a screening test

    Adding Multi-Matrix dimension

    1. Multiple families ID in a single test (vs ELISA)

    2. Sensitive for all/most residues (vs microbiological methods)

    3. High Throughput (+100 samples/day)

    4. Cost-effective and time-saving

  • page09

    BEADYPLEX - “All-In-One” screeningFlow Cytometric Immunoassays – Assay principle

    Immunoanalysis: detection of interaction events(receptor & antibodies).

    Flow Cytometry: multi-parametric characterizationof microparticles (beads) by lazer.

    1. Different sizes2. Different Internal fluorescence intensities

    Multiplexing via microparticles characterized by:

  • page010

    FCIA: simultaneous detection of residues of antibiotics from 10 families in one sample

    in one analysis

    10 different ELISA kits combined in one test

    BEADYPLEX - “All-In-One” screeningFlow Cytometric Immunoassays – Assay principle

  • page011

    BEADYPLEX - “All-In-One” screeningFlow Cytometric Immunoassays – Assay principle

    FLOW CYTOMETRIC COMPETITIVE IMMUNOASSAY

  • page012

    BEADYPLEX - “All-In-One” screeningFlow Cytometric Immunoassays – Assay principle

    BL RL

    Classification of particles

    Determination of assay signal intensity

    Size Internalfluorescence

  • Flow cytometer (NovoCyte 2000, ACEA Biosciences)

    Automatic Reading 3 4 Automatic Reporting

    BEADYPLEXWorkflow for Antibiotic residues

    1Sample preparation 2 Immunoassay

  • BEADYPLEXAnalytical performance – Validation

    Following CRLs Guidelines for the validation of Screening methods for residues of

    veterinary medicines (20/01/2010) based on Commission Decision 2002/657/EC

    Specificity/selectivity

    Cut-Off values

    Detection capabilities

    False positive rates

    Robustness

    Applicability

    page014

  • BEADYPLEXAnalytical performance

    page038

    Detection Limits (CCβ)

    ✓CCβ determined for all detected molecules

    ✓Most of CCβ ≤ MRL

    CCβ (β error ≤ 5%) → concentration for each antibiotic recognized by the FCIA

    for which at least 95% of the samples fortified at this level are identified as “screened positive”

    according to the established assay cut-off values

  • BEADYPLEXAnalytical performance

    page039

    Profile of antibiotic detection (non exhaustive list)

    Detection Limits (CCβ)

  • BEADYPLEXAnalytical performance

    page040

    False positive rate

    Bead n Blank samplesn Screen positive

    False positive rate (%)

    AMINOGLYCOSIDES_A 117 0 0

    AMINOGLYCOSIDES_B 117 0 0

    BETA-LACTAMS 107 0 0

    LINCOSAMIDES 123 0 0

    COLISTIN 122 0 0

    MACROLIDES_A 113 0 0

    MACROLIDES_B 113 0 0

    SULFONAMIDES 107 0 0

    PHENICOLS 118 0 0

    TETRACYCLINES 117 0 0

    (F)QUINOLONES 110 0 0

    PLEUROMUTILINES 122 2 1,6

    False positive rate < to those

    usually atributed to other

    screening methods for

    antibiotics

  • Parameter Condition 1 (control) Condition 2 Condition 3

    SAMPLEEXTRACTION

    EXTRACTION VOLUME 1 ML 0,8 ML 1,2 ML

    AGITATION EXTRACTION TIME 10 MINUTES 5 MINUTES 30 MINUTES

    AGITATION SPEED 6,5 AGITELEC 4,5 AGITELEC 2,5 AGITELEC

    SAMPLE EXTRACTS STORAGE EXTRACTION + ANALYSIS 4°C ON -20°C ON

    EXTRACTION METHOD AGITATION + CENTRIFUGATION STOMACHER -

    ASSAYPROCEDURE

    NUMBER OF PLATE WASHING STEPS 3 1 2

    TEST INCUBATION TEMPERATURE RT 4°C 37°C

    INCUBATION TIME COMPETITIVE STEP 30 MINUTES 15 MINUTES 60 MINUTES

    INCUBATION TIME REPORTERS STEP 15 MINUTES 5 MINUTES 30 MINUTES

    PLATE READING DELAY TEST + READING 1H DELAY ON DELAY

    OTHER

    REAGENTS (BEADS AND PRIMARYBINDERS)

    BATCH 1 BATCH 2 BATCH 3

    OPERATOR A B C

    CYTOMETERS NOVOCYTE ACEA ACCURI C6 BD -

    REAGENTS STABILITY SAME DAY 3 MONTHS 4°C 6 MONTHS 4°C

    BEADYPLEXAnalytical performance

    page041

    Robustness

    ✓No impact of any of the

    evaluated parameters on

    assay performance

    ✓Extraction and analysis

    need to be performed

    the same day

    ✓Very robust method

  • BEADYPLEXAnalytical performance

    page019

    Applicability

    ✓Porcine muscle

    ✓Bovine muscle

    ✓Poultry muscle

    ✓Fish (salmon and colin)

    ✓Milk

    Applicable to

    Honey

    Eggs

    FLEXIBILITY

    ✓Extraction procedure

    adaptation for different

    matrices

    ✓Cut-off modification for

    modulation of applicability

    or sensitivity

  • BEADYPLEXAnalytical performance - Conclusions

    page020

  • BEADYPLEXAnalytical performance - Conclusions

    page021

  • page022

    BEADYPLEXDevelopments

    HormonesSedatives

    Anti-inflammatory

    drugs

    Mycotoxines

    Food allergens

    Foodbornepathogenic

    bacteria

    Antibioticsresidues

  • Allergens

  • FLOW CYTOMETRIC SANDWICH IMMUNOASSAY

    BEADYPLEXFlow Cytometric Immunoassays – Assay principle

    page024

  • page09

    BL RL

    BEADYPLEXFlow Cytometric Immunoassays – Assay principle

    Classification of particles

    Determination of assay signal intensity

    B

    page025

  • page026

    BEADYPLEXLOD/LOQ

    Range

    BLG 0,625 – 40 ppm

    Casein 0,625 – 40 ppm

    Egg 1,25 – 80 ppm

    Peanut 1,25 – 80 ppm

    Soy 1,25 – 80 ppm

  • Hormones Sedatives Anti-inflammatory drugs

  • page028

    BEADYPLEXHormones Sedatives Anti-inflammatory drugs

    Corticosteroids

    Growthpromoters

    Screening multi-class and multi-residue of veterinary drugs in meat/milk or urine by FCIA

    Post-mortem test

    Ante-mortem test

  • Thank you for your attention

    FCIA team

    Alessandro Gallo

    Alexandre Monteforte

    Cédric Pety de Thozée

    Celia Suárez Pantaleón