lot 7 armstrong beach rd armstrong beach, qld · 2015. 4. 21. · 2. powerpoint mount height @...
TRANSCRIPT
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16
17/02/2015 8:00:56 AM
PROPOSED DUPLEX
A0003132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
COVER SHEET
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
DRAWING SCHEDULE
NO DWG TITLE REV REV DATE
A000 COVER SHEET A 24.01.16
A001 PROJECT NOTES A 24.01.16
A010 SITE PLAN A 24.01.16
A101 FLOOR PLAN A 24.01.16
A102 SCHEDULES & PARTY WALL DETAILS A 24.01.16
A111 SLAB SETOUT PLAN A 24.01.16
A112 FRAMING & BRACING PLAN (refer eng.) A 24.01.16
A113 ELECTRICAL PLAN - LIGHTING A 24.01.16
A114 ELECTRICAL PLAN - POWER A 24.01.16
A201 ELEVATIONS A 24.01.16
A202 ELEVATIONS A 24.01.16
A301 TYPICAL SECTION A-A A 24.01.16
A401 3D OVERVIEW A 24.01.16
Rev Date Desc
A 24.01.16 FOR APPROVAL
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16
17/02/2015 8:00:56 AM
PROPOSED DUPLEX
A0013132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
PROJECT NOTES
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
LEGEND - GENERALAW AWNING WINDOWBH BULKHEADBN BENCHCH CEILING HEIGHTCL COLUMN / POSTCPT CARPETCSD CAVITY SLIDING DOORCT COOKTOPDH DOUBLE HUNG WINDOWDP DOWNPIPEDRY CLOTHES DRYERDW DISHWASHERFG FIXED GLAZED WINDOWFGD FROSTED GLASS DOORFRD FRENCH DOUBLE DOORSFRZ FREEZERFW FLOOR WASTEGD GLASS DOORHC EXTERNAL HOSE COCKHWS HOT WATER SYSTEMLV LOUVRE WINDOWMB METER BOXMH MANHOLEOBS OBSCURE GLAZINGPLD PANEL LIFT DOORRD ROLLER DOORSD SMOKE DETECTORSGD SLIDING GLASS DOORSHR SHOWERSK KITCHEN SINKSL SLIDING WINDOWSSWB STAINLESS STEEL WIRE BALUSTRADEREF FRIDGERH RANGEHOODRWT RAINWATER TANKTMB FB TIMBER FLOOR BOARDSTUB LAUNDRY TUBUBO UNDER BENCH OVENVB VANITY BASINWC TOILET SUITEWO WALL OVENWM WASHING MACHINE
SUFFIXES (following any of the above - lower case)o overu under
STANDARD LIGHT, BATTEN HOLDER
1. light switch mount height @ 1250AFFL, uno2. powerpoint mount height @ 300AFFL, uno3. if not stated, provide electrical connection to oven,cooktop, rangehood and dishwasher4. refer general legend for all acronyms not covered inthis legend
F
MSW
P
D
F
MB
SD
L
LEGEND - GENERALLIGHTING
DOWNLIGHT, FLUORO
FLOOD LIGHT
MOTION LIGHT SENSOR
WALL MOUNTED LIGHT
FLUORO BATTEN, 1x1200 LONG
PENDANT LIGHT
FLUORO ROUND LIGHT
LIGHT SWITCH
LIGHT SWITCH, 2 WAY
DIMMER SWITCH
FAN SWITCH, ON / OFF, SPEED
3 in 1 FAN / LIGHT / HEATER
POWER
A/C INT
A/C EXT
SINGLE GPO
DOUBLE GPO
TV OUTLET
PHONE OUTLET
DATA OUTLET
DOUBLE DATA OUTLET
METER BOX
INTERCOM WITH DOOR RELEASE
CEILING FAN
CEILING FAN WITH LIGHT
EXHAUST FAN
A/C UNIT, INTERNAL WALL
A/C UNIT, EXTERNAL
OTHERSMOKE DETECTOR
SUFFIXESFACE OF BENCHANY NUMERAL FOLLOWING ANY OFTHE ABOVE ACRONYMS INDICATESHEIGHT OF FIXTURE / FITTING
OVERUNDERWATERPROOF
FB1500*
OUWP
NOTES
1. PARTICLEBOARD FLOORING19mm THICK YELLOW TONGUE PARTICLEBOARDGLUED & NAILED TO TOP END OF JOISTS. NAILSSHALL BE 10mm FROM ALL EDGES & AT 150 CTRS ATENDS & AT 300 MAX. CTRS. AT INTERMEDIATE JOISTS2. TONGUE & GROOVE FLOORINGBOARDS SHALL BE FITTED INTO GROOVES &CRAMPED. NAILS SHALL BE 12mm FROM BOARDENDS & BUTT JOINTS, & PUNCHED 3mm MIN. BELOWTOP SURFACE.3. MANUFACTURERINSTALL FLOORING AS PER MAUFACTURER'S SPECS4. STRUCTURALREFER STRUCTURAL ENG'S DWGS FOR ADDITIONALFLOORING DETAILS PRIOR TO INSTALLATION5. FLOOR WASTESFLOORS TO ALL WET AREAS TO HAVE A FALL TO AFLOOR WASTE6. WET AREAS - FIRST FLOORSALL WET AREAS TO A FIRST FLOOR TIMBER FLOORSYSTEM TO HAVE AN APPROVED "WET AREA"FLOORING FIXED IN ACCORDANCE WITH THEMANUFACTURER'S SPECS.
NOTES - FLOORING1. ALL DIMENSIONS AND RL's TO BE CHECKED ONSITE BEFORE COMMENCING ANY WORK.2. ALL DIMENSIONS IN MILLIMETRES.3. DO NOT SCALE FROM PLAN. DIMENSIONS TAKEPREFERENCE TO SCALE, & ARE TO STRUCTURE, NOTFINISH, UNLESS NOTED OTHERWISE.4. ALL BUILDING WORK TO COMPLY WITH CURRENTBCA, AUSTRALIAN STANDARDS, RELEVANTSUPPLEMENTS & ALL OTHER RELEVANTAUTHORITIES.5. ALL TIMBER FRAMING TO COMPLY WITH AS1684 &RELEVANT SUPPLEMENTS.6. ALL NEW PLUMBING TO BE CARRIED OUT BY ALICENSED PLUMBER & IS TO BE IN ACCORDANCEWITH ALL RELEVANT AUTHORITIES.7. ALL AREAS NOT ON THE PROPERTY MADE GOODBY THE BUILDER WHERE DISTURBED BY NEW WORK.8. INSTALL SMOKE DETECTORS WHERE REQUIRED INACCORDANCE WITH AS3876.9. ALL FOOTINGS, SLABS, BEAMS, COLUMNS, LINTELS,BRACING & STRUCTURAL MEMBERS TO BE DESIGNED& CERTIFIED BY A QUALIFIED ENGINEER, UNLESSNOTED OTHERWISE10. ALL DEMOLITION WORK TO BE CERTIFIED BYBUILDER AND/OR A QUALIFIED ENGINEER, UNLESSNOTED OTHERWISE11. CONNECT NEW DPs & OVERFLOWS. CONFIRMLOCATION OF STORMWATER TIE, EASEMENTS, & ALLOTHER SERVICES ON SITE BEFORE COMMENCINGWORK.12. PROTECT ALL WALL PENETRATIONS, CAVITIES, &TIMBER MEMBERS WITH AN AUSTRALIAN STANDARDSAPPROVED TERMITE PROTECTION BARRIER SYSTEM,SUCH THAT AN INTERNAL INFESTATION IS NOTPOSSIBLE.13. THE BUILDER IS TO CONFIRM ALL WALLLOCATIONS ON SITE PRIOR TO CONSTRUCTION, TOENSURE NEW BUILDING ENVELOPE FALLS WITHINCOUNCIL SETBACKS AND EASEMENTS.14. ALL TIMBER FRAMED WALLS TO WET AREAS TOBE LINED WITH FIBRE CEMENT SHEETING15. MASONRY CONSTRUCTION TO AS 3700.16. ALL HANDRAILS TO BE 1000mm MIN. ABOVEFINISHED FLOOR (CARPET, TILES ETC), & WITH125mm MAX. SPACING BETWEEN BALUSTRADING17. MATERIALS USED THROUGHOUT TO BE FIXED INACCORDANCE WITH MANUFACTURER'SSPECIFICATIONS UNLESS NOTED OTHERWISE
NOTES - GENERAL
NOTES - MATERIALS1. EXTERNALREFER ELEVATIONS AND FINISHES SCHEDULE (IFPROVIDED) FOR ALL EXTERNAL FINISHES2. INTERNALREFER FINISHES SCHEDULE (IF PROVIDED). TYPICALLYINTERNAL FINISHES ARE AS FOLLOWS UNLESS NOTEDOTHERWISE: Internal Walls: 10mm Plasterboard Wet Area Walls: 6mm Villaboard Internal Ceilings: 10mm Unispan / Plasterboard External Soffits: 4.5mm Hardiflex3. WHERE A FIXTURES SCHEDULE IS NOT PROVIDED,FIXTURES ARE TO BE SELECTED BY THE BUILDER AND/ OR OWNER4. WHERE COLOURS ARE NOT PROVIDED, COLOURSARE TO BE SELECTED BY THE BUILDER AND / OROWNER AND ARE TO COMPLY WITH COUNCIL POLICYAND OTHER RELEVANT AUTHORITIES5. REFER PLANS FOR FLOOR FINISHES. ALL DIFFERINGADJACENT FLOOR FINISHES TO BE FINISHED FLUSHUNLESS NOTED OTHERWISE
NOTES - ROOFING1. TRUSSESTRUSS DESIGN & PLACEMENT OF TRUSSES AS PERMANUFACTURERS DETAILS. BRACING OF TRUSSESAS PER MANUFACTURERS DETAILS2. GUTTERS & DOWNPIPESGUTTERS & DOWNPIPES INSTALLED INACCORDANCE WITH PART 3.5.2 OF THE B.C.A.GUTTERS INSTALLED WITH A FALL OF NOT LESSTHAN -(A) 1:500 FOR EAVES GUTTERS(B) 1:100 FOR BOX GUTTERSDOWNPIPES MUST NOT SERVE MORE THAN 12m OFGUTTER LENGTH FOR EACH DOWNPIPEGENERALLY PROVIDE ONE DOWNPIPE FOR EVERY40sqm OF ROOF AREA (BASED ON A GUTTERMINIMUM CROSS SECTIONAL AREA OF 6300sqmm)3. ROOF SHEETING / TILESINSTALL ROOF MATERIAL AS PER MANUFACTURER'SSPEC & DETAILS. ASSOCIATED ROOF BATTENSINSTALLED ACCORDINGLY4. STRUCTUREALL STRUCTURAL ROOFING MEMBERS TO BEDESIGNED &/OR CERTIFIED BY A QUALIFIED ENG.
NOTES - SERVICES1. ALL NEW PLUMBING TO BE CARRIED OUT BY ALICENSED PLUMBER AND IS TO BE IN ACCORDANCEWITH ALL RELEVANT AUTHORITIES2. CONNECT NEW DPs AND OVERFLOWS. CONFIRMLOCATION OF STORMWATER TIE, EASEMENTS, ANDALL OTHER SERVICES ON SITE BEFORECOMMENCING WORK.3. PRIOR TO ANY EXCAVATION OR CONSTRUCTIONON THE SITE, ALL RELEVANT AUTHORITIES ARE TOBE CONTACTED FOR POSSIBLE LOCATION OFUNDERGROUND SERVICES4. ALL PLUMBING & DRAINAGE TO COMPLY WITHTHE SEWERAGE & WATER SUPPLY ACT 1949, THENATIONAL PLUMBING DRAINAGE CODE AS 3500 ANDANY LOCAL AUTHORITY REQUIREMENTS
NOTES - SITE1. SITE TO BE EXCAVATED AND/OR FILLED TOLEVELS AS SHOWN2. FOOTINGS CONSTRUCTED AS PER BUILDERSSPEC. OR ENG'S DETAILS3. GROUND SURFACE TO BE SLOPED MINIMUM 1:20AWAY FROM BUILDING FOR MINIMUM 900mm OR TO APOINT WHERE PONDING WILL NOT OCCUR NEAR THEBUILDING4. STORMWATER TO BE DISCHARGED TO COUNCILAPPROVED DISCHARGE POINT5. CUT & FILL INDICATED ON PLAN MAY VARY ATCONSTRUCTION STAGE. BUILDER IS TO VERIFY &ADJUST AS REQUIRED. ANY VARIATION IS TOCOMPLY WITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES6. SITE WORKS INDICATED ON RELEVANT DRAWINGSARE FOR CONSTRUCTION PURPOSES ONLY, IT ISTHE CLIENTS RESPONSIBILITY TO CARRY OUR ALLLANDSCAPING, UNLESS NOTED OTHERWISE.7. RETAINING WALLS CONSTRUCTED AS PERBUILDERS SPEC. OR ENG'S DETAILS, & ARE TOCOMPLY WITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES8. CONTOURS & LEVELS AS SHOWN ON DRAWINGSARE DERIVED FROM SUPPLIED SURVEY DRAWING.NO RESPONSIBILITY IS TAKEN FOR ACCURACY OFSURVEY INFORMATION9. BOUNDARY CLEARANCES SHOWN ARE TO BECHECKED & VERIFIED BY BUILDER AT SETOUT &PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANYVARIATION TO SETOUT DIMENSIONS MUST COMPLYWITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES10. ALL FENCING BY OWNER UNLESS NOTEDOTHERWISE & ARE NOT TO EXCEED 1.8 METRESABOVE NATURAL GROUND LEVEL11. UNLESS NOTED OTHERWISE, REMOVAL OFEXISTING TREES & CONSTRUCTION OF RETAININGWALLS WHERE REQUIRED SHALL BE PROVIDED BYTHE OWNER12. DRIVEWAY SLOPE NOT TO EXCEED 1 VERTICALTO 5 HORIZONTAL. DRIVEWAY & FOOTPATH CROSSOVER BY OWNER.13. PRIOR TO ANY EXCAVATION OR CONSTRUCTIONON THE SITE, ALL RELEVANT AUTHORITIES ARE TOBE CONTACTED FOR POSSIBLE LOCATION OFUNDERGROUND SERVICES
NOTES - STRUCTURE1. ALL CONCRETE FOOTINGS, SLABS, BEAMS &COLUMNS TO BE DESIGNED & CERTIFIED BY AQUALIFIED ENGINEER2. SLAB SETOUT PLANS (IF PROVIDED) ARE FORSETOUT ONLY. DETAILS TO BE PROVIDED BYQUALIFIED ENGINEER.3. ALL STEEL STRUCTURAL MEMBERS TO BEDESIGNED & CERTIFIED BY A QUALIFIED ENGINEER.4. ALL DEMOLITION WORK TO BE CERTIFIED BYBUILDER AND/OR A QUALIFIED ENGINEER.5. ENGINEER TO PROVIDE SOIL REPORT PRIOR TOTHE COMMENCEMENT OF ANY WORKS ON SITE. SITETO BE PREPARED IN ACCORDANCE WITH SOILREPORT6. TIMBER MEMBERS DEDUCED FROM AS1684FRAMING MANUALS, MANUFACTURER'S DATAMANUALS & SOFTWARE. REFER ENGINEERSDRAWINGS WHERE NOT PROVIDED7. ALL LAMINATED BEAMS TO HAVE FULL WIDTHBEARING AT EACH END.8. ALL STRUCUTRAL MEMBERS PROVIDED BY THEBUILDING DESIGNER TO BE CERTIFIED BY AQUALIFIED ENGINEER.
NOTES - SUSTAINABLE DESIGN
1. 3 STAR RATED OR AAA RATED SHOWER ROSESA SHOWER ROSE MUST ACHIEVE A MINIMUM 3 STARWATER EFFICIENCY LABELLING & STANDARDS RATING(WELS)2. WATER PRESSURE LIMITINGTHE MAXIMUM PRESSURE LEVEL OF WATER FROMANY OUTLET WITHIN THE PROPERTY BOUNDARIES OFA CLASS 1 BUILDING MUST NOT EXCEED 500kPa3. DUAL FLUSH TOILETSA TOILET MUST HAVE DUAL FLUSH CAPABILITY &MUST ACHIEVE A MINIMUM 4 STAR WATEREFFICIENCY LABELLING & STANDARDS RATING (WELS)4. ENERGY EFFICIENT LIGHTINGENERGY EFFICIENT LIGHTING INCLUDES FLUORO &COMPACT FLUORO LIGHTS. IT DOES NOT INCLUDEINCANDESCENT OR HALOGEN LIGHTS.ENERGY EFFICIENT LIGHTS ARE TO BE USED FOR ATLEAST 80% OF THE TOTAL FLOOR AREA OF THEBUILDING, WHICH INCLUDES GARAGES. ELECTRICIANMUST ADVISE ON COMPLIANCE.5. HOT WATER SUPPLYA HOT WATER SYSTEM IN A CLASS 1 BUILDING MUSTCOMPLY WITH THE QUEENSLAND PLUMBING &WASTEWATER CODE.6. RAINWATER TANKSWHERE A RAINWATER TANK IS INSTALLED IT WILL -(A) HAS A MINIMUM STORAGE CAPACITY OF 5000L FORA DETACHED CLASS 1 BUILDING(B) IS INSTALLED TO RECIEVE RAINWATER FROM AMINIMUM ROOF CATCHMENT AREA THAT IS AT LEASTONE HALF OF THE TOTAL ROOF AREA OR 100sqm,WHICHEVER IS THE LESSER(C) IS CONNECTED TO TOILET CISTERNS ANDWASHING MACHINE COLD WATER TAPS, EXTERNALUSE (HOSE COCKS) & OTHER FIXTURES AS SPECIFIEDBY THE LOCAL GOVERNMENT IN A LOCAL PLANNINGINSTRUMENT.7. GREYWATERWHERE A GREYWATER TREATMENT PLANT ISINSTALLED IT WILL -RECIEVE GREYWATER FROM ALL BATHROOMSANITARY OUTLETS IN THE BUILDING, HAVE AMINIMUM PROCESSING CAPACITY TO TREAT TOTALGREYWATER INPUT VESSEL VOLUME IN 24 HOURS,AND HAS A STORAGE CAPACITY NOT EXCEEDING2000L
PART MP 4.0 - BUILDING SUSTAINABILITYQUEENSLAND DEVELOPMENT CODE
NOTES - TERMITE PROTECTION1. TIMBER PROTECTION FROM TERMITES INACCORDANCE WITH AS36602. BUILDER TO CONFIRM WITH OWNER THE CHOSENMETHOD OF TIMBER PROTECTION3. OWNER REMAINS RESPONSIBLE FOR ONGOINGINSPECTIONS OF STRUCTURAL TIMBER, & THATBARRIERS ARE NOT COMPROMISED4. INSTALL ANT CAPPINGS TO ALL BRICK PIERS,TIMBER OR CONCRETE STUMPS. KEEP TIMBERCLEAR OF GROUND WHEN ON STEEL ANCHORS5. ALL TIMBER IN DIRECT CONTACT WITHCONCRETE TO BE SEPERATED BY G.I. FLASHING OROTHER APPROVED METHOD / MATERIAL6. 75mm MIN. OF EXPOSED SLAB EDGES TO REMAINABOVE FINISHED PERIMETER LEVEL AND NOT TO BECOVERED BY SOIL, OR RENDERED, OR TILED, BUTMAY BE PAINTED.
Rev Date Desc
A 24.01.16 FOR APPROVAL
ARMS
TRON
G BE
ACH
RD
19275
19275
42250
42250
PROPOSED DWELLING(ROOF AREA: 327sqm)
42.250m
42.250m
19.27
5m
19.27
5m
UNIT 1
UNIT 2
MB HWS
HWS
1495
16285
(ROOF
)149
5
1495
16285
(ROOF
)149
5
6550 19220 (UNIT 2 ROOF) 16480
5550 19220 (UNIT 2 ROOF) 17480
6000 18320 (UNIT 2 WALLS) 17930
1945
15385
(WAL
LS)
1945
7000 18320 (UNIT 1 WALLS) 16930
1945
15385
(WAL
LS)
1945
5000
1800 HIGH 'GOOD NEIGHBOUR'TIMBER PALING FENCE TO REAR ANDSIDE BOUNDARIES AND BETWEENREAR YARDS. GATE TOWARD FRONTOF HOUSE AS SHOWN
01:200
2 4m
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16 1 : 200
17/02/2015 8:00:57 AM
PROPOSED DUPLEX
A0103132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
SITE PLAN
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
PROPERTY DETAILS
NOTE: CHECK BOUNDARY DIMENSIONS &CONTOURS ON SITE PRIOR TO CONSTRUCTION
LOT NUMBER:RP/SP NUMBER:PARISH:COUNTY:LOCAL AUTHORITY:SITE ZONING:PRECINCT:
PROPERTY INFORMATION
SITE AREA:EXISTING FOOTPRINT:
PROPOSED FOOTPRINT:
SITE AREA INFORMATION
NOTE: FOOTPRINT CALCULATED TO OUTSIDE EXT.WALLS. INCLUDES OUTDOOR COVERED AREAS
7SP266405
814.0sqm
MACKAY CC--
--274.6sqm33.7%
NOTES - SITE1. SITE TO BE EXCAVATED AND/OR FILLED TOLEVELS AS SHOWN2. FOOTINGS CONSTRUCTED AS PER BUILDERSSPEC. OR ENG'S DETAILS3. GROUND SURFACE TO BE SLOPED MINIMUM 1:20AWAY FROM BUILDING FOR MINIMUM 900mm OR TO APOINT WHERE PONDING WILL NOT OCCUR NEAR THEBUILDING4. STORMWATER TO BE DISCHARGED TO COUNCILAPPROVED DISCHARGE POINT5. CUT & FILL INDICATED ON PLAN MAY VARY ATCONSTRUCTION STAGE. BUILDER IS TO VERIFY &ADJUST AS REQUIRED. ANY VARIATION IS TOCOMPLY WITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES6. SITE WORKS INDICATED ON RELEVANT DRAWINGSARE FOR CONSTRUCTION PURPOSES ONLY, IT ISTHE CLIENTS RESPONSIBILITY TO CARRY OUR ALLLANDSCAPING, UNLESS NOTED OTHERWISE.7. RETAINING WALLS CONSTRUCTED AS PERBUILDERS SPEC. OR ENG'S DETAILS, & ARE TOCOMPLY WITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES8. CONTOURS & LEVELS AS SHOWN ON DRAWINGSARE DERIVED FROM SUPPLIED SURVEY DRAWING.NO RESPONSIBILITY IS TAKEN FOR ACCURACY OFSURVEY INFORMATION9. BOUNDARY CLEARANCES SHOWN ARE TO BECHECKED & VERIFIED BY BUILDER AT SETOUT &PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANYVARIATION TO SETOUT DIMENSIONS MUST COMPLYWITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES10. ALL FENCING BY OWNER UNLESS NOTEDOTHERWISE & ARE NOT TO EXCEED 1.8 METRESABOVE NATURAL GROUND LEVEL11. UNLESS NOTED OTHERWISE, REMOVAL OFEXISTING TREES & CONSTRUCTION OF RETAININGWALLS WHERE REQUIRED SHALL BE PROVIDED BYTHE OWNER12. DRIVEWAY SLOPE NOT TO EXCEED 1 VERTICALTO 5 HORIZONTAL. DRIVEWAY & FOOTPATH CROSSOVER BY OWNER.13. PRIOR TO ANY EXCAVATION OR CONSTRUCTIONON THE SITE, ALL RELEVANT AUTHORITIES ARE TOBE CONTACTED FOR POSSIBLE LOCATION OFUNDERGROUND SERVICES
Rev Date Desc
A 24.01.16 FOR APPROVAL
LIN. LIN.
ROBE
ROBE
SHR
WC
VB
REF
PTRY
WM TUB DW
SK
CT RH
UBO B/BA
R
OHC
VBWC
SHR
SDSD
LIN. LIN.
ROBE
ROBE
SHR
WC
VB
REF
PTRY
WM TUB DW
SK
CT RH
UBO
B/BA
ROHC
VBWC
SHR
SDSD
PARTY WALL 60/60/60 FRL(INSTALL AS PER MANUF. SPECS)
NOMINAL SYSTEM - CSR 361
UNIT 1
UNIT 2
D09 D10D15
D11D23 D24
D03
D04
D21
D16 D17
D27
D28
/1.2 1.8 SWW04
/0.3 1.8 SWW05
/0.3 1.2 SWW03
/0.6
1.8SW
W06
D06
D05
/0.3
1.2SW
W07
/1.8
1.8SW
W02
D14 D13
D18D12
D26 D25
D02
D01
D22
D19 D20
D29
D30
/1.2 1.8 SWW11
/0.3 1.8 SWW10
/0.3 1.2 SWW12
/0.6
1.8SW
W09
D07
D08
/0.3
1.2SW
W08
/1.8
1.8SW
W01
Bed 3CARPET
PorchCONC
GarageCONC
Bed 2CARPET
Bed 1CARPET
AlfrescoCONC
Bed 1CARPET
AlfrescoCONC
Bed 2CARPET
Bed 3CARPET
PorchCONC
Kit'nTILE
Kit'nTILE
DiningTILE
LivingTILE
DiningTILE
LivingTILE
GarageCONC
EnsTILEWIR
CARPET
WIRCARPET
EnsTILE
BathTILE
BathTILE
HC MBDP
FW
FW
DP
DP
DP DP DP
DP
DPDP
switc
hbo
ard
switc
hbo
ard
90stud
90stud
230240
070
53070
1180
90300
0245
3000
90118
070
53070
2400
230
230900
70203
070
1180
90300
0245
3000
90118
070
2030
70900
230
230300
090
1020
230300
0245
3000
230102
090
3000
230
2420
1920
3605
3100
1920
2420
450153
85450
230300
070
4270
245427
070
3000
230
2770
230300
070
1500
245150
070
3000
230277
0
2770
5185
4660
2770
450153
85450
1000 230 6900 70 600 1200 800 3840 70 1500 70 1840 70 900 230
2500 230 11510 70 3780 230
1540 90 3000 70 530 70 1600 70 530 70 3000 70 3600 230 3850
450 18320 450
230 6900 70 600 1200 800 3840 70 1500 70 1840 70 900 230 1000
2500 230 11510 70 3780 230
1540 90 3000 70 530 70 1600 70 530 70 3000 70 3600 230 3850
450 18320 450
70 1000 600 70
70 1000 600 70
350157
0
350 1190
350 1190
350157
0
HWS
HWS
90SHSSTEEL POST
90SHSSTEEL POST
350sq BRICKPOST
350sq BRICKPOST
FW
FW
HC
HC
HC
A202 1- -
01:100
1 2m
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16 1 : 100
17/02/2015 8:00:59 AM
PROPOSED DUPLEX
A1013132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
FLOOR PLAN
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
SCHEDULE OF AREASSITE AREA
BUILDING AREA (PER UNIT)LIVINGGARAGEALFRESCOPORCHTOTAL
BUILDING AREA (TOTAL)
sqm
sqmsqmsqmsqmsqm
sqm
99.623.1
274.6
137.3
805.0
10.73.9
SCALE 1 : 1001 FLOOR PLAN
LEGEND - GENERALAW AWNING WINDOWBH BULKHEADBN BENCHCH CEILING HEIGHTCL COLUMN / POSTCPT CARPETCSD CAVITY SLIDING DOORCT COOKTOPDH DOUBLE HUNG WINDOWDP DOWNPIPEDRY CLOTHES DRYERDW DISHWASHERFG FIXED GLAZED WINDOWFGD FROSTED GLASS DOORFRD FRENCH DOUBLE DOORSFRZ FREEZERFW FLOOR WASTEGD GLASS DOORHC EXTERNAL HOSE COCKHWS HOT WATER SYSTEMLV LOUVRE WINDOWMB METER BOXMH MANHOLEOBS OBSCURE GLAZINGPLD PANEL LIFT DOORRD ROLLER DOORSD SMOKE DETECTORSGD SLIDING GLASS DOORSHR SHOWERSK KITCHEN SINKSL SLIDING WINDOWSSWB STAINLESS STEEL WIRE BALUSTRADEREF FRIDGERH RANGEHOODRWT RAINWATER TANKTMB FB TIMBER FLOOR BOARDSTUB LAUNDRY TUBUBO UNDER BENCH OVENVB VANITY BASINWC TOILET SUITEWO WALL OVENWM WASHING MACHINE
SUFFIXES (following any of the above - lower case)o overu under
Rev Date Desc
A 24.01.16 FOR APPROVAL
SCALE 1 : 1002 Floor Level
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16
17/02/2015 8:01:00 AM
PROPOSED DUPLEX
A1023132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
SCHEDULES & PARTYWALL DETAILS
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
DOOR SCHEDULE
NO HEIGHT WIDTH TYPED01 2100 820 2100 x 820 Swing Door (External)D02 2100 2400 2124 PanelLift GarageD03 2100 2400 2124 PanelLift GarageD04 2100 820 2100 x 820 Swing Door (External)D05 2100 2100 2121 Sliding Glass Door (2 Panel)D06 2100 2100 2121 Sliding Glass Door (2 Panel)D07 2100 2100 2121 Sliding Glass Door (2 Panel)D08 2100 2100 2121 Sliding Glass Door (2 Panel)D09 2100 820 2100 x 820 Swing Door (Internal)D10 2100 820 2100 x 820 Swing Door (Internal)D11 2100 820 2100 x 820 Swing Door (Internal)D12 2100 820 2100 x 820 Swing Door (Internal)D13 2100 820 2100 x 820 Swing Door (Internal)D14 2100 820 2100 x 820 Swing Door (Internal)D15 2100 720 2100 x 720 Swing Door (Internal)D16 2100 720 2100 x 720 Swing Door (Internal)D17 2100 720 2100 x 720 Swing Door (Internal)D18 2100 720 2100 x 720 Swing Door (Internal)D19 2100 720 2100 x 720 Swing Door (Internal)D20 2100 720 2100 x 720 Swing Door (Internal)D21 2100 820 2100x820 Cavity Sliding DoorD22 2100 820 2100x820 Cavity Sliding DoorD23 2100 470 2100 x 470 Cupboard Door (Internal)D24 2100 470 2100 x 470 Cupboard Door (Internal)D25 2100 470 2100 x 470 Cupboard Door (Internal)D26 2100 470 2100 x 470 Cupboard Door (Internal)D27 2100 2100 2100 x 2100 Sliding Cupboard DoorD28 2100 2100 2100 x 2100 Sliding Cupboard DoorD29 2100 2100 2100 x 2100 Sliding Cupboard DoorD30 2100 2100 2100 x 2100 Sliding Cupboard Door
WINDOW SCHEDULE
NO HEIGHT WIDTH TYPEW01 1800 1800 1818 Sliding WindowW02 1800 1800 1818 Sliding WindowW03 300 1200 0312 Sliding WindowW04 1200 1800 1218 Sliding WindowW05 300 1800 0318 Sliding WindowW06 600 1800 0618 Sliding WindowW07 300 1200 0312 Sliding WindowW08 300 1200 0312 Sliding WindowW09 600 1800 0618 Sliding WindowW10 300 1800 0318 Sliding WindowW11 1200 1800 1218 Sliding WindowW12 300 1200 0312 Sliding Window
NOMINAL SYSTEM(CSR 361)
Rev Date Desc
A 24.01.16 FOR APPROVAL
SHR
WC
VB
TUB
SK
VBWC
SHR
SHR
WC
VB
TUB
SK
VBWC
SHR
FW
FW
FW
FW
150 SDN
DOO
R
DOOR
DOO
R
DOO
R
DOO
R
DOOR
150 S
DN
150 S
DN 150 SDN
HOUSE SLABASSUMED RL 00.250
GAR
AGE D
OO
R
FALL SLAB
PATIO SLABASSUMED RL 00.100
HOUSE SLABASSUMED RL 00.250
PATIO SLABASSUMED RL 00.100
SHR SETDOWN.NOM. 50mm
GAR
AGE D
OO
R
SHR SETDOWN.NOM. 50mm
SHR SETDOWN.NOM. 50mm
SHR SETDOWN.NOM. 50mm
90SHSSTEEL POST
90SHSSTEEL POST
350sq BRICKPOST
350sq BRICKPOST
7570
245757
0
230900
900230
2420
900102
0310
0360
5102
0900
2420
350157
0350
1570
2420
1920
3605
3100
1920
2420
140151
05140
530240
0
465240
0
FALL SLAB
2770
4800
245480
0277
0
2770
4660
5185
2770
17190 900 230 1000
1000
1000
1540 12930 3850
18320
350 1190 3760 1600
1540 960
1540 960
17190 900 230
1540 12930 3850
18320
1540 3760 1600
15385
3300
1500
245150
0330
0
01:100
1 2m
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16 1 : 100
17/02/2015 8:01:01 AM
PROPOSED DUPLEX
A1113132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
SLAB SETOUT PLAN
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
SCALE 1 : 1001 SLAB SETOUT PLAN
Rev Date Desc
A 24.01.16 FOR APPROVAL
01:100
1 2m
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16 1 : 100
17/02/2015 8:01:01 AM
PROPOSED DUPLEX
A1123132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
FRAMING & BRACINGPLAN (refer eng.)
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
SCALE 1 : 1001 FRAMING & BRACING PLAN (refer eng.)
Rev Date Desc
A 24.01.16 FOR APPROVAL
switc
hbo
ard
MB
switc
hbo
ard
01:100
1 2m
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16 1 : 100
17/02/2015 8:01:02 AM
PROPOSED DUPLEX
A1133132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
ELECTRICAL PLAN -LIGHTING
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
SCALE 1 : 1001 ELEC PLAN - LIGHTING
STANDARD LIGHT, BATTEN HOLDER
1. light switch mount height @ 1250AFFL, uno2. powerpoint mount height @ 300AFFL, uno3. if not stated, provide electrical connection to oven,cooktop, rangehood and dishwasher4. refer general legend for all acronyms not covered inthis legend
F
MSW
P
D
F
MB
SD
L
LEGEND - GENERALLIGHTING
DOWNLIGHT, FLUORO
FLOOD LIGHT
MOTION LIGHT SENSOR
WALL MOUNTED LIGHT
FLUORO BATTEN, 1x1200 LONG
PENDANT LIGHT
FLUORO ROUND LIGHT
LIGHT SWITCH
LIGHT SWITCH, 2 WAY
DIMMER SWITCH
FAN SWITCH, ON / OFF, SPEED
3 in 1 FAN / LIGHT / HEATER
POWER
A/C INT
A/C EXT
SINGLE GPO
DOUBLE GPO
TV OUTLET
PHONE OUTLET
DATA OUTLET
DOUBLE DATA OUTLET
METER BOX
INTERCOM WITH DOOR RELEASE
CEILING FAN
CEILING FAN WITH LIGHT
EXHAUST FAN
A/C UNIT, INTERNAL WALL
A/C UNIT, EXTERNAL
OTHERSMOKE DETECTOR
SUFFIXESFACE OF BENCHANY NUMERAL FOLLOWING ANY OFTHE ABOVE ACRONYMS INDICATESHEIGHT OF FIXTURE / FITTING
OVERUNDERWATERPROOF
FB1500*
OUWP
NOTES
Rev Date Desc
A 24.01.16 FOR APPROVAL
switc
hbo
ard
MB
RH UBO
REF
DIRECT CONNECTFOR UBO/CT
DW
A/C INT A/C EXT
A/C IN
T
A/C EXT
GARAGE DOOR(ceiling mount for panel lift)
WP
switc
hbo
ard
RH UBO
REF
DIRECT CONNECTFOR UBO/CT
DW
A/C INT A/C EXT
A/C IN
T
A/C EXT
GARAGE DOOR(ceiling mount for panel lift)
WP
01:100
1 2m
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16 1 : 100
17/02/2015 8:01:03 AM
PROPOSED DUPLEX
A1143132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
ELECTRICAL PLAN -POWER
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
SCALE 1 : 1001 ELEC PLAN - POWER
STANDARD LIGHT, BATTEN HOLDER
1. light switch mount height @ 1250AFFL, uno2. powerpoint mount height @ 300AFFL, uno3. if not stated, provide electrical connection to oven,cooktop, rangehood and dishwasher4. refer general legend for all acronyms not covered inthis legend
F
MSW
P
D
F
MB
SD
L
LEGEND - GENERALLIGHTING
DOWNLIGHT, FLUORO
FLOOD LIGHT
MOTION LIGHT SENSOR
WALL MOUNTED LIGHT
FLUORO BATTEN, 1x1200 LONG
PENDANT LIGHT
FLUORO ROUND LIGHT
LIGHT SWITCH
LIGHT SWITCH, 2 WAY
DIMMER SWITCH
FAN SWITCH, ON / OFF, SPEED
3 in 1 FAN / LIGHT / HEATER
POWER
A/C INT
A/C EXT
SINGLE GPO
DOUBLE GPO
TV OUTLET
PHONE OUTLET
DATA OUTLET
DOUBLE DATA OUTLET
METER BOX
INTERCOM WITH DOOR RELEASE
CEILING FAN
CEILING FAN WITH LIGHT
EXHAUST FAN
A/C UNIT, INTERNAL WALL
A/C UNIT, EXTERNAL
OTHERSMOKE DETECTOR
SUFFIXESFACE OF BENCHANY NUMERAL FOLLOWING ANY OFTHE ABOVE ACRONYMS INDICATESHEIGHT OF FIXTURE / FITTING
OVERUNDERWATERPROOF
FB1500*
OUWP
NOTES
Rev Date Desc
A 24.01.16 FOR APPROVAL
FLOOR LEVEL0
FLOOR LEVEL0
CEILING LEVEL2440
CEILING LEVEL2440
'COLORBOND CUSTOMORB' METALSHEET ROOFING AT 20° PITCH
SELECTED COLORBONDFASCIAS & GUTTERS
RENDERED BRICKWORKTYPICAL EXTERNAL FINISH
NOTE:RL'S TO BE CONFIRMED.CONFIRM ON SITE
ALUMINIUM FRAME WINDOWAND DOOR SUITES TYPICAL
SCYON STRIA 405CLADDING ON TIMBER STUDTO FRONT & RETURN SIDEWALL AS SHOWN
/0.3 1.2 SWW12
/1.2 1.8 SWW11
/0.3 1.8 SWW10
D07
FLOOR LEVEL0
FLOOR LEVEL0
CEILING LEVEL2440
CEILING LEVEL2440
'COLORBOND CUSTOMORB' METALSHEET ROOFING AT 20° PITCH
SELECTED COLORBONDFASCIAS & GUTTERS
RENDERED BRICKWORKTYPICAL EXTERNAL FINISH
ALUMINIUM FRAME WINDOWAND DOOR SUITES TYPICAL
D08 /0.6 1.8 SWW09
/0.3 1.2 SWW08
/0.3 1.2 SWW07
/0.6 1.8 SWW06 D05
01:100
1 2m
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16 1 : 100
17/02/2015 8:01:05 AM
PROPOSED DUPLEX
A2013132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
ELEVATIONS
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
SCALE 1 : 1001 ELEVATION A
SCALE 1 : 1002 ELEVATION B
Rev Date Desc
A 24.01.16 FOR APPROVAL
FLOOR LEVEL0
FLOOR LEVEL0
CEILING LEVEL2440
CEILING LEVEL2440
'COLORBOND CUSTOMORB' METALSHEET ROOFING AT 20° PITCH
SELECTED COLORBONDFASCIAS & GUTTERS
RENDERED BRICKWORKTYPICAL EXTERNAL FINISH
ALUMINIUM FRAME WINDOWAND DOOR SUITES TYPICAL
SCYON STRIA 405 CLADDINGON TIMBER STUD TO FRONT& RETURN AS SHOWN
/1.8 1.8 SWW02 D03D04 D01D02 /1.8 1.8 SW
W01
FLOOR LEVEL0
FLOOR LEVEL0
CEILING LEVEL2440
CEILING LEVEL2440
'COLORBOND CUSTOMORB' METALSHEET ROOFING AT 22° PITCH
SELECTED COLORBONDFASCIAS & GUTTERS
RENDERED BRICKWORKTYPICAL EXTERNAL FINISH
ALUMINIUM FRAME WINDOWAND DOOR SUITES TYPICAL
SCYON SCYON STRIA 405 CLADDINGON TIMBER STUD TO FRONT & RETURNSIDE WALL AS SHOWN
D06 /0.3 1.8 SWW05
/1.2 1.8 SWW04
/0.3 1.2 SWW03
01:100
1 2m
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16 1 : 100
17/02/2015 8:01:07 AM
PROPOSED DUPLEX
A2023132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
ELEVATIONS
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
SCALE 1 : 1001 ELEVATION C
SCALE 1 : 1002 ELEVATION D
Rev Date Desc
A 24.01.16 FOR APPROVAL
FLOOR LEVEL0
FLOOR LEVEL0
CEILING LEVEL2440
CEILING LEVEL2440
PART
Y W
ALL 6
0/60
/60 F
RL(IN
STAL
L AS P
ER M
ANUF
. SPE
CS)
NOM
INAL
SYST
EM -
CSR
361
FLOOR FINISHES ASSELECTED. REFER PLAN
PLASTERBOARD WALLLINING TYPICAL
CONCRETE SLAB & FOOTINGS AS PER ENG'SDWGS. REFER FLOOR PLAN FOR FINISHES
NOTE: TERMITE PROTECTION BY BUILDER, TOBE IN ACCORDANCE WITH AS3660.
SELECTED METAL SHEETROOFING AT 20° PITCH
SELECTED COLORBONDFASCIAS, GUTTERS &DOWNPIPES
FC SOFFIT LINING
TIMBER ROOF TRUSS AS PERMANUFACTURER'S DETAILS
GROUND LEVEL NOM.200mm BELOW SLAB LEVEL
FLUSH PLASTERBOARDCEILING TYPICAL
CONFIRM FFL'S ON SITE
01:50
1m0.5
Iss Date Issue Description
project no dwg no issue
scale size
A3date
design drawn check approve
titleproject
project addressGeneral Note: Builder to check & verify all dimensions, levels, etc. as notedon this/these drawings & be fully aware of any additional notes on approvedcopy of same drawing before commencing any setting out of works,ordering of materials, and/or construction work. All works must comply withthe Building Code of Australia, Australian Standards & all other relevantauthorities. All work must be carried to best tradesman like manner & to thefull satisfaction of the owner.
clie
nt
ARC Template System © Latemore Design
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) [email protected] www.kodadesign.com.au
1 : 50
17/02/2015 8:01:08 AM
PROPOSED DUPLEX TYPICAL SECTION A-A
A3013132
01/14/15
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
SCALE 1 : 501 TYPICAL CROSS SECTION
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
Rev Date Revision Description
A 24.01.16 FOR APPROVAL
01:100
1 2m
project no dwg no issue
scale size
A3date
design drawn check approve
project
project address
General Note: Builder to check & verify all dimensions, levels, etc. asnoted on this/these drawings & be fully aware of any additional notes onapproved copy of same drawing before commencing any setting out ofworks, ordering of materials, and/or construction work. All works mustcomply with the Building Code of Australia, Australian Standards & allother relevant authorities. All work must be carried out in the best oftradesman like manner & to the full satisfaction of the owner.
Koda Design Pty.Ltd.PO Box 55 Holland Park QLD 4121
ACN 137 818 645BDAQ Member No:1208 BSA License No:1170922
t (07) 32193756e [email protected] www.kodadesign.com.au
client
ARC Template System © Latemore Design
title
A
24.01.16
17/02/2015 8:01:10 AM
PROPOSED DUPLEX
A4013132
DNP DNP DNP JC
LOT 7 ARMSTRONG BEACH RDARMSTRONG BEACH, QLD
FOR APPROVAL
3D OVERVIEW
Escape Homesp 1300 725 514m 0431 421 181
w escapehomes.com.aue [email protected]
Rev Date Desc
A 24.01.16 FOR APPROVAL
Part 6
- Lan
dscap
e Plan