low differential pressure gage

13
WO81 WO70 FR51A MS30 MS61A MS65 EB3C EMD8 EMD7 EMT6 EMP5 EMA3 EMRT1 HWS15 EMT1 EMTGP1 EMT1H Combination of Manosys Accessories Application Cautions for use Maintenance Manostar Gage WO81 General purpose type Low Differential Pressure Gage RoHS compliant Utility model registration No.823971 V Only vertical H Only upward horizontal Blank Both vertical and upward horizontal D Pa E kPa Max. value of scale N Without flag pointer S With one flag pointer T With two flag pointers F Surface installation type PC Panel installation round type PR Panel installation square type F N 50 D V (example) Installation position Unit Range Flag pointer Type Product code W O 8 1 Pressure range code If you order or ask, please specify the product code and the pressure range code. Refer to p.7 for the instrument displayed the air volume and velocity scale. WO81FN (surface installation type with non flag pointer) WO81PRS (panel installation square type with one flag pointer) WO81PCT (panel installation round type with two flag pointers) Broad line-up of product Supporting the air volume scale and the air velocity scale (refer to p.7) Readable wide-angle scale (Angle of the pointer- rocation is 270 ° ) It is easy to convert polarity enable by piping connector Even when the pressure becomes excessive, the original mechanism avoid damage to moving parts. Small hysteresis is realized by the silicone rubber diaphragm. The pointer is not fluctated by the original band- linked mechanism. WO81FT (surface installation type with two flag pointers) <Example of main use field> Nuclear facilities Air conditioning control system of the food factories Air conditioning control system of the high-rise buildings Hospital and medical facilities Production lines of the car and the semi-conductor Exhaust gas pressure control of coffee-roaster machines <Example of use> Measuring the inside pressure of clean rooms Detection of the pressure loss of an air filter Measuring air volume and velocity in a ventilator and an exhauster. (refer to p.93) 3 Low Differential Pressure Gage

Upload: others

Post on 29-Jun-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combinationof Manosys

Accessories

ApplicationCautions for useMaintenance

Manostar Gage WO81 General purpose type Low Differential Pressure GageRoHS compliant

Utility model registrationNo.823971

V Only vertical

H Only upward horizontal

Blank Both vertical and upward horizontal

D Pa

E kPa

Max. value of scale

N Without flag pointer

S With one flag pointer

T With two flag pointers

F Surface installation type

PC Panel installation round type

PR Panel installation square type

F N 50 D V (example)

Installation position

Unit

Range

Flag pointer

Type

Product code

W O 8 1

Pressure range code

◆If you order or ask, please specify the product code and the pressure range code.◆Refer to p.7 for the instrument displayed the air volume and velocity scale.

WO81FN(surface installation type with non flag pointer)

WO81PRS(panel installation square type with one flag pointer)

WO81PCT(panel installation round type with two flag pointers)

・Broad line-up of product

・Supporting the air volume scale and the air velocity scale (refer to p.7)

・Readable wide-angle scale (Angle of the pointer-rocation is 270 °)

・It is easy to convert polarity enable by piping connector

・Even when the pressure becomes excessive, the original mechanism avoid damage to moving parts.

・Small hysteresis is realized by the silicone rubber diaphragm.

・The pointer is not fluctated by the original band-linked mechanism.

WO81FT(surface installation type with two flag pointers)

<Example of main use field>Nuclear facilitiesAir conditioning control system of the food factoriesAir conditioning control system of the high-rise buildingsHospital and medical facilitiesProduction lines of the car and the semi-conductorExhaust gas pressure control of coffee-roaster machines

<Example of use>Measuring the inside pressure of clean roomsDetection of the pressure loss of an air filterMeasuring air volume and velocity in a ventilator and an exhauster.

*(refer to p.93)

3

Low Differential Pressure Gage

Page 2: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combination of Manosys

Accessories

ApplicationCautions for useMaintenance

Types

Bodies

Flag pointers

Surface installation type Panel installation round type Panel installation square type

F PC PR

Non flag pointer N WO81 F N WO81 PC N WO81 PR N

One flag pointer (red) S WO81 F S WO81 PC S WO81 PR S

Two flag pointers (red and green) T WO81 F T WO81 PC T WO81 PR T

Pressure units

Pressure measuring method

Pressure receiving element

Gas to be measured

Scale indicating angle

Medium and ambient temperature

Ambient humidity

Withstanding pressure of instrument body

Material of outer case

Withstanding impact

Withstanding vibration

Pa, kPa

Measuring differential pressure

Diaphragm

Air or non-corrosive gas (not liquid)

Approximately 270 ° Wide-angle indication

- 10 to + 50 ℃ (no freezing)

90 % RH or less (no dewing)

200 kPa (refer to p.104)

Polycarbonate and polyamide

100 m/s2(each 6 times on triaxial directions)

5 to 10 Hz Amplitude : 10 mm10 to 50 Hz Acceleration : 39 m/s2

(each two hours on triaxial directions)

Applicable piping

Polarity of piping connector

Mass

・Vinyl, plastic or rubber tube (I.D. 6) ...The resinous piping connectors (installed) for vinyl or

plastic tube.・Metal tube (O.D. 6 ± 0.1) ...Metal type piping connector (option) is needed. ・Hard plastic tube (O.D. 6 × I.D. 4) ...Metal type piping connector (option) and Inner sleeve set

(XIN6 × 4) are needed.(refer to p.92)

・The piping connector indicated red color is high pressure side and blue color is low pressure side.

・Enabling to convert the polarity by changing piping connectors of high pressure side for low pressure side.

Approximately 270 g

AccessoriesOne set of screws for installation Two sets of adaptors for installation

(with main body)One set of nuts for installation

(with main body)

WO81F WO81PC WO81PR

Specification

Pressure range codes Pressure rangesStandard installation

positions (refer to p.10)

Accuracies (at 20 ℃ )

Material of pressure receiving element

Withstanding pressures of receiving element

(refer to p.104)

   50 DH   0 ~   50 Pa 

Upward horizontal (fixed) ± 5 % FS

Silicone rubber

 10 kPa

   50 DV Vertical (fixed)

   100 DH   0 ~    100 Pa 

Upward horizontal (fixed)

± 2.5 % FS   100 DV Vertical (fixed)

   200 D     0 ~    200 Pa 

Installation position from upward horizontal to vertical

is available.

   300 D 

   500 D 

  1000 D 

   0 ~    300 Pa 

   0 ~    500 Pa 

   0 ~  1000 Pa 

± 1.5 % FS

 40 kPa    2 E 

    3 E 

    5 E 

   0 ~     2 kPa

   0 ~     3 kPa

   0 ~     5 kPa

   10 E 

   20 E 

   30 E 

   50 E 

   100 E 

   0 ~   10 kPa

   0 ~   20 kPa

   0 ~   30 kPa

   0 ~   50 kPa

   0 ~    100 kPa

150 kPa

 +- 50 DH - 50 ~ + 50 Pa 

Upward horizontal (fixed)

± 2.5 % FS  10 kPa +- 50 DV Vertical (fixed)

 +- 100 D   - 100 ~ + 100 Pa 

Installation position from upward horizontal to vertical

is available.

 +- 200 D 

 +- 300 D 

 +- 500 D 

+-1000 D 

 - 200 ~ + 200 Pa 

 - 300 ~ + 300 Pa 

 - 500 ~ + 500 Pa 

-1000 ~ +1000 Pa ± 1.5 % FS  40 kPa

  +-  2 E 

  +-  3 E 

-  2 ~ +  2 kPa

-  3 ~ +  3 kPa

4

WO81

Page 3: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combinationof Manosys

Accessories

ApplicationCautions for useMaintenance

Scale table of Manostar Gage WO81 modelSingle pressure range

◆It is charged to print + or - sign on scale plate.

Actual size

Installation position Pressure range Min. scaleHorizontal   0 ~ 50 Pa 0.5 PaVertical   0 ~ 50 Pa 0.5 Pa

Installation position Pressure range Min. scaleHorizontal   0 ~ 100 Pa 1 PaVertical   0 ~ 100 Pa 1 Pa

0 ~ 1000 Pa 10 Pa

Pressure range Min. scale0 ~ 2 kPa 0.02 kPa0 ~ 20 kPa 0.2 kPa

Pressure range Min. scale0 ~ 3 kPa 0.02 kPa0 ~ 30 kPa 0.2 kPa

Pressure range Min. scale0 ~ 5 kPa 0.05 kPa0 ~ 50 kPa 0.5 kPa

Pressure range Min. scale0 ~ 10 kPa 0.1 kPa0 ~ 100 kPa 1  kPa

Pressure range Min. scale0 ~ 300 Pa 2 Pa

Pressure range Min. scale0 ~ 500 Pa 5 Pa

Pressure range Min. scale0 ~ 200 Pa 2 Pa

5

Low Differential Pressure Gage

Page 4: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combination of Manosys

Accessories

ApplicationCautions for useMaintenance

Zero point center range

Installation position Pressure range Min. scaleHorizontal   -50~+50 Pa 1 PaVertical   -50~+50 Pa 1 Pa

Pressure range Min. scale-200~+200 Pa 5 Pa

Pressure range Min. scale-3~+3 kPa 0.05 kPa

Actual size

Pressure range Min. scale-500~+500 Pa 10 Pa

Pressure range Min. scale-100~+100  Pa 2 Pa-1000~+1000 Pa 20 Pa

Pressure range Min. scale-300~+300 Pa 5 Pa

Pressure range Min. scale-2~+2 kPa 0.05 kPa

6

WO81

Page 5: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combinationof Manosys

Accessories

ApplicationCautions for useMaintenance

V Only vertical

H Only upward horizontal

Blank Both vertical and upward horizontal

DM Pa (dynamic pressure Pa)

EM kPa (dynamic pressure kPa)

Max. value of scale

N without flag pointer

S With one flag pointer

T With two flag pointers

F Surface installation type

PC Panel installation round type

PR panel installation square type

F N 49 DM V (example)

Installation position

Unit

Range

Flag pointer

Type

Product code

W O 8 1

Pressure range code

◆If you order or ask, please specify the product code and the pressure range code.

Air volume Air velocity

m3/h

m3/h×10

m3/h×1000

m3/h×10000

m3/h(nor)

m3/h(nor)×10

m3/h(nor)×1000

m3/h(nor)×10000

m3/min

m3/min×10

m3/min×1000

m3/min×10000

m3/min(nor)

m3/min(nor)×10

m3/min(nor)×1000

m3/min(nor)×10000

m / s

Data sheet for calculating air volume or velocity.(Please inform us data sheet ① or ② for calculating air volume or velocity. Base on data sheet, we issue you specification of air volume or velocity scale.)To make out the specification based on gas condition (temp, humidity, static pressure, density), size of the duct and medium flow rate. →①To make out the scale specification based on the relationship between air volume (or velocity) and dynamic pressure.(If the detector is a orifice and so on.) →②

For calculating air volume

or velocity ①

Gas to be measured data

Working regular air volume (velocity) value

Max. air volume (velocity) value

Duct size

In case of mixed gas, please specify the density of mixed gas.

Used pressuredetector

I.D. ( ) mm or square duct ( ) mm ×( ) mm

Gas temperature          Gas density

Gas humidity Static pressure at the point to be measured

% RH

Pa

Please f i l l in the va lue o f the point to be measured to installing the pressure detector.

kg/m3

* Air density is 1,200 kg/m3 at normal state.

For calculating airvolume or velocity ②

Using condition               value is at             

                is measured till ( )

When air volume (velocity)

Max. air volume (velocity)

dynamic pressure   Pa

◆If you order the air volume and velocity meter, please tell us the data for calculating air volume and velocity.◆The max. value of air volume and velocity is rounding off to our printing scale.◆The max. pressure value correspond to the max. value of air volume (velocity) is written in scale plate.

WO81FN(surface installation type with non flag pointer)

Display unit

Manostar Gage WO81 General purpose type Air volume and velocity meters

This and next page is introduction pages for air volume and velocity meter of WO81.Refer to p.3, p.4 for low differenctial pressure gage of WO81.

Total static pressure tube (Pitot tube)

Total pressure tube + Static puressure tube

Multi-pitot tube(corrected air volume coefficient)

7

Low Differential Pressure Gage

Page 6: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combination of Manosys

Accessories

ApplicationCautions for useMaintenance

Air volume or velocity range(example scale)

Actual size

Types

BodiesFlag pointers

Surface installation type Panel installation round type Panel installation square typeF PC PR

Non flag pointer N WO81 F N WO81 PC N WO81 PR NOne flag pointer (red) S WO81 F S WO81 PC S WO81 PR STwo flag pointers (red and green) T WO81 F T WO81 PC T WO81 PR T

units

Pressure measuring method

Pressure receiving element

Gas to be measured

Scale indicating angleMedium and ambient

temperature Ambient humidity

Withstanding pressure of instrument body

Material of outer case

Withstanding impact

Withstanding vibration

Air volume and air velocityMeasuring differential pressureDiaphragmAir or non-corrosive gas (not liquid)Approximately 270 ° Wide-angle indication- 10 to + 50 ℃ (no freezing)90 % RH or less (no dewing)200 kPa (refer to p.104)Polycarbonate and polyamide100 m/s2(each 6 times on triaxial directions)5 to 10 Hz Amplitude : 10 mm10 to 50 Hz Acceleration : 39 m/s2

(each two hours on triaxial directions)

Applicable piping

Polarity of piping connector

Mass

・Vinyl, plastic or rubber tube (I.D. 6) ...The resinous piping connectors (installed) for vinyl or

plastic tube.

・Metal tube (O.D. 6 ± 0.1) ...Metal type piping connector (option) is needed.

・Hard plastic tube (O.D. 6 × I.D. 4) ...Metal type piping connector (option) and Inner sleeve set

(XIN6 × 4) are needed.(refer to p.92)

・The piping connector indicated red color is high pressure side and blue color is low pressure side.

・Enabling to convert the polarity by changing piping connectors of high pressure side for low pressure side.

Approximately 270 g

AccessoriesOne set of screws for installation Two sets of adaptors for installation (with main body) One set of nuts for installation (with main body)

WO81F WO81PC WO81PR

Specification

Pressure range codes Air volume and

air velocity range(example scale)

Standard installation positions

(refer to p.10)Accuracies (at 20 ℃ )

Material of pressure receiving element

Withstanding pressures of receiving element

(refer to p.104)

 49 DMH

It is depend on specification of air velocity and air volume scale.

Upward horizontal (fixed)

 ± 5 % FS or less

Silicone rubber

 10 kPa

 49 DMV Vertical (fixed) 70 DMH Upward horizontal (fixed) 70 DMV Vertical (fixed) 100 DMH Upward horizontal (fixed)

± 2.5 % FS or less

 100 DMV Vertical (fixed) 130 DMH Upward horizontal (fixed) 130 DMV Vertical (fixed) 180 DMH Upward horizontal (fixed)

 40 kPa

 180 DMV Vertical (fixed) 250 DM 

Installation position from upward horizontal to vertical

is available.

 300 DM  400 DM  580 DM 1000 DM 

± 1.5 % FS or less 1.8 EM  3.2 EM  4.5 EM  8.5 EM  10 EM  150 kPa

(Note) Number :Rounding off, Magnification :×10, ×1000, ×10000, Unit :m3/h, m3/min, m3/h(nor), m3/min(nor), m/s◆In ordering out of above mentioned installation position, please order us or our agency beforehand. It must be adjusted before the factory shipment.

Air volume scale

Air velocity scale

8

WO81

Page 7: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combinationof Manosys

Accessories

ApplicationCautions for useMaintenance

Outline drawing

WO81F Arrangement of the piping connectors

Manostar Gage WO81F

The piping connector installed on side view (in factory-setting)

φ 114 ± 0.3

69

79

27

φ 7

138

Flag pointer

Flag pointer

3 × φ 5 (installation holes)3 × 120 °segmentation

Pointer

φ 114

Hex.14

φ 128

Setting device of zero point

φ 101

Setting device ofthe green flag pointer

Setting device ofthe red flag pointer

Seal plug

Panel cut size

or 3 × M4 holes tapped

3 × φ 5 holes

3 × 120 °segmentation

Side arrangement of piping connectors

134121

φ 7

Hex.14

φ 6

± 0

.1

Hex.14

Hex.12

Appli

cable

pipin

g diam

eter

(143)

VT connector for vinyl or plastic tube

Caution

Tighten the piping connectors with the torque of 1 N・m.Tighten the seal plugs with the torque of 0.5 N・m.Do not apply excessive torque more than necessary, otherwise it will damage the instrument body.Be sure to use a locking spanner at connectors to tighten the cap nut of metal tube. Be careful not to let the tightening torque directly load to the main body of the instrument.

!( )

MT connector for metal tube VR rotary connector for vinyl or plastic tube

9

Low Differential Pressure Gage

Page 8: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combination of Manosys

Accessories

ApplicationCautions for useMaintenance

WO81 Installation position

◆In ordering out of above mentioned installation position, please order us or our agency beforehand. It must be adjusted before the factory shipment.◆In case of ordering standerd installation position, you do not specify installation position. Please specify pressure range code in the specification table.

Vertical plane

a

a

b

Vertical plane

Verti

cal

Verti

cal

Downward horizontal Downward horizontalUpward horizontal Upward horizontal

Horizontal plane Horizontal planeInstall

ation p

osition

angle

upward

45 °

Installation position

angle downward 135 °

Installation position

angle downward 135 °

10 ° 10 °10 °

20 °20 °

20 °

a Specified installation position b Following installation position is available Standard installation position

Pressure range specified vertical or upward horizontal that is standard installation position. Installation position from upward horizonral to vertical is available.

Rear arrangement of the piping connector

φ 114 ± 0.3

Panel cut size

79

Appli

cable

pipi

ngdia

mete

r

Piping adaptor on back view(30)

Hex.14

Hex.12

φ 6

± 0

.1

or 3 × M4 holes tapped3 × 120 °segmentation

2 × φ 18 holes

3 × φ 5 holes

15

19

26

Hex.14Panel cut size

3 × φ 5 holesor 3 × M4 holes tapped3 × 120 °segmentation

Piping adaptor on back view(Long hole)

R9

φ 114 ± 0.379

To change arrangement of piping connectors of WO81F

WO81F have two piping connector ports on side and back view.It is possible to four kinds of arrangement by combination of piping.

Possible arrangement of piping connectors

Pipingconnector

PipingconnectorSeal plug

Seal plug

Impossible arrangement of piping connectors

Pipingconnector

Pipingconnector

Seal plug

Seal plug

VT connector for vinyl or plastic tube MT connector for metal tube

VR rotary connector for vinyl or plastic tube

0 ~ 50 Pa, 0 ~ 100 Pa, - 50 ~ + 50 Pa

The gage that pressure range is from 0 ~ 50 Pa is impossible to install on downward horizontal.

All other ranges except for the following

1.Use set of piping connectors, which is set of a red connector on high pressure side and a blue connector on low pressure side.

2.Be careful that there is impossible arrangement as shown on the right figure.

3.With seal plugs, be sure to close the two piping connector ports where connectors are not attached.

Caution

Caution

Tighten the piping connectors with the torque of 1 N·m.Tighten the seal plugs with the torque of 0.5 N·m.Do not apply excessive torque more than necessary, otherwise it will damage the instrument body.Be sure to use a locking spanner at connectors to tighten the cap nut of metal tube. Be careful not to let the tightening torque directly load to the main body of the instrument.

!( )

10

WO81

Page 9: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combinationof Manosys

Accessories

ApplicationCautions for useMaintenance

Manostar Gage WO81PCOutline drawing

Arrangement of piping connector (example)

How to install WO81PC

φ 7

17

φ 9

5

77

72φ 100

Panel cut size

φ 96 ± 0.3(hole)

Hex.14

Two sets of the installationbracket

φ 6

± 0

.1

Hex.14

(74)

Hex.12

Appli

cable

pipin

g diam

eter

70

63

φ 7

Hex.14

Driver

Screw A Screw A

Installation screw B

Installationadaptor

InstallationadaptorPanel

VT connector MT connector

VR connector

1. Loose screw A, and remove two installation adaptors.

2. Install the instrument body from the front side of the panel. Set two installation adaptors and tighten the screws A so that they were put into the original position.

3. Tighten two installation screws B alternately and fasten the instrument body to the panel.

Caution

Tighten the piping connectors with the torque of 1 N·m.Do not apply excessive torque more than necessary, otherwise it will damage the instrument body.Be sure to use a locking spanner at connectors to tighten the cap nut of metal tube. Be careful not to let the tightening torque directly load to the main body of the instrument.

!( )

Caution

Tighten the installation screws B with the torque from 0.5 to 0.6 N·m.Do not apply excessive torque more than necessary, otherwise it will damage the instrument body.

11

Low Differential Pressure Gage

Page 10: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combination of Manosys

Accessories

ApplicationCautions for useMaintenance

Manostar Gage WO81PROutline drawing

Arrangement of piping connector (example)

How to install WO81PR

100

100

6821

φ 9

5

φ 7

77

Four sets ofM4 installation screw

Hex.14

Panel cut size

80

80

φ 96 ± 0.3(hole)

80 ±

0.3

80 ± 0.3 4 × φ 5(hole)

φ 6

± 0

.1

(70)

Hex.14Hex.12

Appli

cable

pipin

g diam

eter

Hex.14

5966

φ 7

Max. thickness installed panel 6 mm

M4 nut

Spring washer

Plain washer

Spacer nut

VT connector MT connector

VR connector

1. Remove M4 nuts, spring washers and plain washers on four corners, but don't remove spacer nuts.

(When you install the instrument body on the panel, keep on attaching spacer nuts to the instrument body.)

2. After installing the instrument body on the panel, set plain washers and spring washers. Then tighten four sets of M4 nuts from the back side of panel.

Caution

Tighten the piping connectors with the torque of 1 N·m.Do not apply excessive torque more than necessary, otherwise it will damage the instrument body.Be sure to use a locking spanner at connectors to tighten the cap nut of metal tube. Be careful not to let the tightening torque directly load to the main body of the instrument.

!( )

Caution

If you install the instrument on the panel with no spacer nuts, the instrument body will be broken.

12

WO81

Page 11: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combinationof Manosys

Accessories

ApplicationCautions for useMaintenance

Manostar Gage WO81Main structure

RoHS compliantAccessory for WO81

11

12

13

1098 76 5

44

32

1

Installation bracket to set for WO81 PC type Portable box for WO81 model

The combination shown in the above photo is a set of the installation adaptor.This set is intended for reserve. These two sets are attached to the body as standard accessory.

Product code TKA81PC  Product code PB⊖01(The gage is not included.)

No. Name

1 Diaphragm

2 Low pressure side piping connector (blue)

3 High pressure side piping connector (red)

4 Seal plug

5 Scale plate

6 Setting device of zero point

7 Setting device of the flag pointer

8 Pointer

9 Flag pointer

10 Clear cover

11 Housing

12 Cover packing

13 Cover ring

13

Low Differential Pressure Gage

Page 12: Low Differential Pressure Gage

WO81

WO70

FR51A

MS30

MS61A

MS65

EB3C

EMD8

EMD7

EMT6

EMP5

EMA3

EMRT1

HWS15

EMT1

EMTGP1

EMT1H

Combination of Manosys

Accessories

ApplicationCautions for useMaintenance

RoHS compliantAccessory for WO81

* Because of quality improvement or any reason, some specifications are possibility of changing without notice.

PT connectorThe joint installed tube is push-in type. Use the optional tube (NT4-6, refer to p.88) or the applicable tube (JIS B8381-1).

PR connectorThe joint installed tube is push-in and rotary elbow type.

MT connector(ring joint type)This connector can be connected to the metal tube made from copper, aluminum and so on (O.D. 6, the tolerance ± 0.1).In case of connecting with stainless tube, use MTW connector.When this connector is connected to hard plastic tube (O.D. 6, I.D. 4), remove the brass-made sleeve and use the resinous inner sleeve set (XIN6 × 4, refer to p.88) that is the optional accessory.

MR connectorThis connector is rotary elbow type and can be connected to the metal tube (made from copper and aluminum and so on.).Applicable piping material is the same as MT connector.When this connector is connected to hard plastic tube (O.D. 6, I.D. 4), remove brass-made sleeve and use the resinous inner sleeve set (XIN6 × 4, refer to p.88) that is the optional accessory.

Piping adaptor on back view When you install MT, VR and MR connector (except for MTW connector) on back side port of WO81F type, this adaptor is necessary to avoid interference with connectors and panel. It is also necessary as a spacer to use a locking spanner at this adaptor.

MTW connector(double ring joint type)This connector can be connected to stainless tube (O.D. 6, the tolerance ± 0.1).This connector is made of stainless steel. (SUS316)

VR connectorThese connectors are rotary elbow type and can be connected to vinyl, plastic and rubber tube of I.D.6.

VT connectorTo attach vinyl, plastic or rubber tube to the instrument body (spare parts)

MT connector

Product code KGA81MT-H Product code KGA81MT-L

VR connector

PR connector

Product code KGA81VR-H

Product code KGA81PR-H

Product code KGA81VR-L

Product code KGA81PR-L

MR connector

Product code KGA81MR-H Product code KGA81MR-L

Piping adaptor on back view

Product code KGA81FBA-H Product code KGA81FBA-L

MTW connector

Product code KGA81MTW-H-S Product code KGA81MTW-L-S

Product code KGA81VT-L-P

Product code KGA81PT-L

Seal plug

Product code KGA81PLG

VT connector

PT connector

Product code KGA81VT-H-P

Product code KGA81PT-H

(for F type on back view)

High pressure side

High pressure side

High pressure side

High pressure side

High pressure side

High pressure side

High pressure side

High pressure side

Low pressure side

Low pressure side

Low pressure side

Low pressure side

Low pressure side

Low pressure side

Low pressure side

Low pressure side (for F type on back view)

14

WO81

Page 13: Low Differential Pressure Gage

April 2011 YAMAMOTO ELECTRIC WORKS CO.,LTD.

R

Manostar General Catalog Low differential pressure gage/Manostar gage/Manostar switch/Manosys

T H E G E N E R A L C A T A L O G

R

We appreciate the importance of air.Manostar gage WO81

April 2011The first edition contrasted with the 9th Japanese product catalog

Manostar General Catalog

1-2-3, Nishishiriike-cho, Nagata-ku, Kobe, Hyogo 653-0031 JAPANTEL. +81(78)621-7000 FAX. +81(78)621-7788

1-2-3, Nishishiriike-cho, Nagata-ku, Kobe, Hyogo 653-0031 JAPANTEL. +81(78)631-6000 FAX. +81(78)631-6020

ManufactuerSole Agent

Product Warranty

Warranty PeriodThis product warranty is valid for one year from the date of delivery to a place specified by an ordering party who has transacted directly with Yamamoto Electric Works Co., Ltd.

CoverageIf a product breaks down due to a reason for which we are responsible during the warranty period and you return the product to us, we will either repair or replace the product free of charge.This warranty does not cover:(1) Usage of the product under any inappropriate conditions or environment contrary to what is described

in our product catalog, specifications or manual.Handling or usage of the product other than as described in our product catalog, specifications or manual.

(2) Breakdown due to a reason other than a fault within our product.(3) Any product that has been modified or repaired by a party other than us.(4) Any breakdown due to a reason that was not foreseeable based on scientific and technical standards

applied at the time of shipment.(5) Any breakdown due to a reason not attributable to us such as a natural calamity or other disaster.

These terms of warranty represent our entire liability with respect to the product, and we shall have no liability for any other loss arising in connection with a breakdown of the product.

*This product warranty is only valid within Japan.