low voltage systems life cycle services mx, md, lk and mns … · 2018. 5. 9. · our support team...

2
Our support team can do it n Cubicle additions n Modernizations n Renovations and repairs n Construction changes n Transfers n Special switchgears n Spare parts n Motor starters n LV circuit breaker retrofits UNELEC and Strömberg OTNB circuit breakers can be replaced depending on the application with a new circuit breaker or fuse switch Benefits Compatibility without modification of a switchgear Minimized space requirements Increased protection and safety Guaranteed spare part and technical support when using genuine, factory certified products Easy assembly Easy maintenance Uniform appearance MX, MD, LK and MNS switchgear Increase the availability and extend the lifetime of your switchgear Low Voltage Systems life cycle services

Upload: others

Post on 29-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • Our support team can do itn Cubicle additionsn Modernizationsn Renovations and repairsn Construction changesn Transfersn Special switchgearsn Spare partsn Motor startersn LV circuit breaker retrofits

    − UNELEC and Strömberg OTNB circuit breakers can be replaced depending on the application with a new circuit breaker or fuse switch

    Benefits − Compatibility without modification of a switchgear − Minimized space requirements − Increased protection and safety − Guaranteed spare part and technical support when

    using genuine, factory certified products − Easy assembly − Easy maintenance − Uniform appearance

    MX, MD, LK and MNS switchgearIncrease the availability and extend the lifetimeof your switchgear

    Low Voltage Systems life cycle services

  • 1TFC

    902

    036N

    0201

    ©

    Cop

    yrig

    ht 2

    012

    AB

    B.

    All

    right

    s re

    serv

    ed.

    Switchgear type

    MXA

    MXB

    MD_

    LK

    Un/V

    380, 500, 660 V;

    50 Hz

    380, 500, 660 V;

    50 Hz

    380, 500, 660 V;

    50 Hz

    380 ...660 V;

    50 Hz

    In/A

    Main busbars

    Vertical busbars

    1000 ...3150 A

    315 ... 1800 A

    1000 ...3150 A

    630 ... 1600 A

    800 ... 4000 A

    400 ... 2000 A

    600 ... 3150 A (4000 A)

    630 ...1600 A

    Ith/kA

    Idyn/kA

    20...50 kA, 1 s

    40...105 kA

    40...50 kA, 1 s

    105 kA

    31.5...80 kA, 1 s

    67...176 kA

    12.5...50 kA, 1 s

    25...105 kA

    IP

    IP20, IP44

    IP20, IP44

    IP20, IP34, IP54

    IP20, IP21, IP32, IP44

    ABB Oy, Low Voltage SystemsP.O. Box 600FI-65101 Vaasa, FinlandPhone: +358 10 22 11 www.abb.com