Low voltage Extract from Tesys Catalogue | 2016
Motorstarters
Protection
Reliable
Thermal overload relays
Circuit breakers
Motor
Contactors
Flexible
Smar
t
controllers
Fuse switch-disconnectors
TeSys Motor controllers
B12/1
Mo
tor
con
tro
llers
Motor management systems
Motor management system - TeSys U Type of product Range Pages
Motor controller TeSys U B12/2
Current transformers for TeSys U motor controller From 30 to 800 A B12/2
Type 2 coordination table for assemblies of: b circuit breaker + contactor + TeSys U controller + current transformerb fuses + contactor + TeSys U controller + current transformer
B12/3
Motor management system - TeSys T
Controllers with Modbus, or CANopen, Devicenet, Profibus, Ethernet TCP/IP communication port
B12/4
Extension modules B12/5
HMI terminal and cables B12/5
Accessories B12/6
TeSy
s Control and Protection Components
Chapter
B12
Technical Data for Designers B12/9
B12/2
TeSys U
ReferencesControl bases (auxiliary supply voltage c 24 V)Connection For use
with contactorReference Weight
kg Current transformers
Control
Screws Screws LC1Dpp LUTM10BL 0.800
LC1Fppp LUTM20BL 0.800
Control unitsDescription Class For motor
typeSetting range Reference Weight
kgAdvanced 10 3-phase 0.35…1.05 LUCBT1BL 0.140
20 3-phase 0.35…1.05 LUCDT1BL 0.140
Multifunction 5 to 30 3-phase 0.35…1.05 LUCMT1BL 0.175
Current transformersOperating current Reference Weight
kgPrimary Secondary30 1 LUTC0301 0.550
50 1 LUTC0501 0.330
100 1 LUTC1001 0.450
200 1 LUTC2001 0.590
400 1 LUTC4001 0.870
800 1 LUTC8001 1.210
Function modules and communication modulesThe TeSys U controller is compatible with the modules listed below:
b Thermal overload alarm module LUF W10, b Motor load indication module LUF V2, b Communication modules: v Modbus (LUL C033), v CANopen (LULC08), v DeviceNet (LULC09), v Advantys STB (LUL C15).
Note: Communication modules LUL C07 (Profibus DP), ASILUF C5 and ASILUF C51 (AS-Interface) are not compatible with the TeSys U controller. Module LUF W10 is only compatible with control units LUCB T1BL and LUCD T1BL.
References Motor management systemTeSys U controllers
Presentation: pages B12/10 and B12/11
Characteristics: pages B12/12 and B12/13
Dimensions, mounting: page B12/14
Schemes: page B12/15
LUT M + LUCM T1BL + LUTC pp
DF5
2612
0.tif
B12/3
TeSys U
Mo
tor
con
tro
llers
Combinations providing type 2 coordinationWith Circuit breakerStandard power ratings of 3-phase motors 50-60 Hz in category AC-3 400/415 V
Circuit breaker Contactor TeSys U controller
Current transformers
PkW IeA Reference Rating A
Irm (1)
AReference (2) Reference Reference
18.5 35 GV3L40 40 560 LC1D50A LUTM + LUCp 3 x LUTC050122 41 GV3L50 50 700 LC1D50A LUTM + LUCp 3 x LUTC100130 55 GV3L65 65 910 LC1D65A LUTM + LUCp 3 x LUTC100137 66 NSX80HMA 80 1040 LC1D80 LUTM + LUCp 3 x LUTC100145 80 NSX100HMA 100 1300 LC1D95 LUTM + LUCp 3 x LUTC100155 97 NSX160HMA 150 1350 LC1D115 LUTM + LUCp 3 x LUTC200175 132 NSX160HMA 150 1800 LC1D150 LUTM + LUCp 3 x LUTC200190 160 NSX250HMA 220 2200 LC1F185 LUTM + LUCp 3 x LUTC2001110 195 NSX250HMA 220 2640 LC1F225 LUTM + LUCp 3 x LUTC4001132 230 NSX400HMA 320 3200 LC1F265 LUTM + LUCp 3 x LUTC4001160 280 NSX400HMA 320 4160 LC1F330 LUTM + LUCp 3 x LUTC4001200 350 NSX630HMA 500 5000 LC1F400 LUTM + LUCp 3 x LUTC4001220 385 NSX630HMA 500 5500 LC1F400 LUTM + LUCp 3 x LUTC4001250 430 NSX630HMA 500 6000 LC1F500 LUTM + LUCp 3 x LUTC8001
With fusesStandard power ratings of 3-phase motors 50-60 Hz in category AC-3 400/415 V
Switch-disconnector fuse
aM fuses Contactor TeSys U controller
Current transformers
PkW IeA Reference Size Rating A
Reference (2) Reference Reference
18.5 35 GSpF 14 x 51 40 LC1D40A LUTM + LUCp 3 x LUTC050122 41 GSpJ 22 x 58 50 LC1D50A LUTM + LUCp 3 x LUTC100130 55 GSpJ 22 x 58 80 LC1D80 LUTM + LUCp 3 x LUTC100137 66 GSpJ 22 x 58 100 LC1D80 LUTM + LUCp 3 x LUTC100145 80 GSpJ 22 x 58 100 LC1D95 LUTM + LUCp 3 x LUTC100155 97 GSpL T0 125 LC1D115 LUTM + LUCp 3 x LUTC200175 132 GSpL T0 160 LC1D150 LUTM + LUCp 3 x LUTC200190 160 GSpN T1 200 LC1F185 LUTM + LUCp 3 x LUTC2001110 195 GSpN T1 250 LC1F225 LUTM + LUCp 3 x LUTC4001132 230 GSpQQ T2 315 LC1F265 LUTM + LUCp 3 x LUTC4001160 280 GSpQQ T2 400 LC1F330 LUTM + LUCp 3 x LUTC4001200 350 GS2S T3 500 LC1F400 LUTM + LUCp 3 x LUTC4001220 385 GS2S T3 500 LC1F400 LUTM + LUCp 3 x LUTC4001250 430 GS2S T3 500 LC1F500 LUTM + LUCp 3 x LUTC8001315 540 GS2S T3 630 LC1F630 LUTM + LUCp 3 x LUTC8001
(1) Irm: setting current of the magnetic trip.(2) For reversing operation, replace the prefix LC1 with LC2.
Combinations Motor management systemTeSys U controllers
Presentation: pages B12/10 and B12/11
Characteristics: pages B12/12 and B12/13
References: page B12/2
Dimensions, mounting: page B12/14
Schemes: page B12/15
B12/4
TeSys T
ControllersSetting range Control voltage Current range Reference
A V AFor Modbus
8 c 24 0.4...8 LTMR08MBDa 100...240 0.4...8 LTMR08MFM
27 c 24 1.35...27 LTMR27MBDa 100...240 1.35...27 LTMR27MFM
100 c 24 5...100 LTMR100MBDa 100...240 5...100 LTMR100MFM
For CANopen8 c 24 0.4...8 LTMR08CBD
a 100...240 0.4...8 LTMR08CFM27 c 24 1.35...27 LTMR27CBD
a 100...240 1.35...27 LTMR27CFM100 c 24 5...100 LTMR100CBD
a 100...240 5...100 LTMR100CFMFor DeviceNet
8 c 24 0.4...8 LTMR08DBDa 100...240 0.4...8 LTMR08DFM
27 c 24 1.35...27 LTMR27DBDa 100...240 1.35...27 LTMR27DFM
100 c 24 5...100 LTMR100DBDa 100...240 5...100 LTMR100DFM
For Profibus DP8 c 24 0.4...8 LTMR08PBD
a 100...240 0.4...8 LTMR08PFM27 c 24 1.35...27 LTMR27PBD
a 100...240 1.35...27 LTMR27PFM100 c 24 5...100 LTMR100PBD
a 100...240 5...100 LTMR100PFMFor Ethernet TCP/IP (communication protocols: Modbus/TCP and EtherNet/IP)
8 c 24 0.4...8 LTMR08EBDa 100...240 0.4...8 LTMR08EFM
27 c 24 1.35...27 LTMR27EBDa 100...240 1.35...27 LTMR27EFM
100 c 24 5...100 LTMR100EBDa 100...240 5...100 LTMR100EFM
FilterControl voltage Current max ReferenceV mA
a 150...240 130 LTM9F
References Protection componentsTeSys T Motor Management System
LTM R08EBD
CP
B10
0750
-00.
eps
PF5
2638
7-47
-M.e
ps
LTM R08MBD
PF5
2638
8-47
-M.e
ps
LTM R08CBD
PF5
2638
9-47
-M.e
ps
LTM R08DBD
PF5
2639
0-47
-M.e
ps
LTM R08PBD
Presentation: pages B12/16 to B12/26
Characteristics: pages B12/27 to B12/31
Dimensions, mounting: pages B12/32 to B12/33
Schemes: pages B12/34 to B12/37
Combination for customer assembly: pages B12/38 to B12/41
B12/5
TeSys T
Mo
tor
con
tro
llers
References
Extension modules (with voltage measurement on the 3 phases)Input control voltage
Number of inputs
Supply to the electronics Reference
Vc 24 4 Via the controller LTMEV40BD a 100…240 4 Via the controller LTMEV40FM
HMI terminalsDescription Supply
VoltageReference
Operator control unit
Languages:EnglishFrenchSpanish
Supply via the controller
LTMCU
Operator control unit with Fast DeviceReplacement Service (FDR)
Languages:EnglishFrenchSpanish
Supplyvia the controller
LTMCUF
Kit for portable LTM CU LTM9KCUMagelis compact display. c 24 V external XBTN410Description Number and type
of connectorsLengthm
Reference
Connecting cables for the LTM CU control unit
2 x RJ45 1 LTM9CU103 LTM9CU30
Connecting cablesfor the XBT N410
SUB-D 25-way female RJ45
2.5 XBTZ938
CablesDescription Number and type
of connectorsLength Referencem
Connecting cables For connecting the controller to the extension module
2 x RJ45 0.04 LTMCC004 (1)
0.3 LTM9CEXP031 LTM9CEXP10
Replacement connectorsDescription Number and type
of connectorsReference
Complete set of connectors for controllers and extension modules
10 screw terminals (all network versions included)
LTM9TCS
Connector extraction tool LTM9TCT (2)
(1) Sold in lots of 6.(2) Sold in packs of 3.
Protection componentsTeSys T Motor Management System
LTM EV40BD
PF5
2638
0-30
-M.e
ps
LTM CU
PF5
6860
5-54
-M.e
ps
Presentation: pages B12/16 to B12/26
Characteristics: pages B12/27 to B12/31
Dimensions, mounting: pages B12/32 to B12/33
Schemes: pages B12/34 to B12/37
Combination for customer assembly: pages B12/38 to B12/41
B12/6
TeSys T
References
Configuration toolsDescription Composition Reference Weight
kgConnection cable for PC USB to RJ45 cable, lenght 2.5 m TCSMCNAM3M002P 0.200
Current transformers (1)
Operational current Reference WeightPrimary SecondaryA A kg
100 1 (2) LT6CT1001 0.550200 1 (2) LT6CT2001 0.550400 1 (2) LT6CT4001 0.550800 1 (2) LT6CT8001 0.680
Earth fault toroids (marketed under the Schneider Electric brand)Rated operational current Ie
Internal Ø of toroid
Reference Weight
A mm kgClosed toroids, type A
65 30 50437 0.12085 50 50438 0.200160 80 50439 0.420250 120 50440 0.530400 200 50441 1.320630 300 50442 2.230
Split toroids, type OA85 46 50485 1.300250 110 50486 3.200
PTC thermistor probes (3)
Description Nominal Operating Temperature (NOT)
Colour Unit reference (4)
°CTriple probes 90 Green/green DA1TT090
110 Brown/brown DA1TT110120 Grey/grey DA1TT120130 Blue/blue DA1TT130140 White/blue DA1TT140150 Black/black DA1TT150160 Blue/red DA1TT160170 White/green DA1TT170
(1) The transformers offered for use with TeSys U starters are suitable. Please consult our "TeSys U starter-controllers" catalogue.(2) For use with LTM R08pp controllers.(3) PTC: Positive Temperature Coefficient.(4) Sold in lots of 10.
Protection componentsTeSys T Motor Management System
LT6 CT4001
PF5
2639
3.ep
s
DA1 TTppp
PF5
1057
5.ep
s
Presentation: pages B12/16 to B12/26
Characteristics: pages B12/27 to B12/31
Dimensions, mounting: pages B12/32 to B12/33
Schemes: pages B12/34 to B12/37
Combination for customer assembly: pages B12/38 to B12/41
B12/7
TeSys T
Mo
tor
con
tro
llers
References
Marking accessories (to be ordered separately)Description Composition Height
mm
Unit reference
Weight
kgClip-in markers Strips of 10 identical
numbers (0 to 9) or capital letters (A to Z)
5 NSYTRABF5p (1) 0.002
6 NSYTRABF6p (1) 0.002
Connection accessoriesDescription Length Reference Weight
m kgFor Modbus connection
Cables fitted with 2 x RJ45 connectors 0.3 VW3A8306R03 0.0451 VW3A8306R10 0.0653 VW3A8306R30 0.125
T-junctions 0.3 VW3A8306TF03 0.0321 VW3A8306TF10 0.032
RS 485 line terminator – VW3A8306R 0.012
For CANopen connectionCables 50 TSXCANCA50 4.930
100 TSXCANCA100 8.800300 TSXCANCA300 24.560
IP20 connectorsSUB-D 9-way femaleLine end adapter switch
Elbowed (90°) – TSXCANKCDF90T 0.046Straight – TSXCANKCDF180T 0.049Elbowed (90°) with SUB-D 9-way connector for connection to PC or diagnostic tool
– TSXCANKCDF90TP 0.051
For DeviceNet connectionCables 50 TSXCANCA50 4.930
100 TSXCANCA100 8.800300 TSXCANCA300 24.560
For Profibus DP connection (2)
Cables 100 TSXPBSCA100 –400 TSXPBSCA400 –
Connectors With line terminator – 490NAD91103 –
Without line terminator – 490NAD91104 –
With line terminator and terminal port
– 490NAD91105 –
For Ethernet TCP/IP connectionShielded twisted pair cables to standard EIA/TIA568
Cables fitted with 2 x RJ45 connectors for connection to terminal equipment
Straight 2 490NTW00002 –5 490NTW00005 –12 490NTW00012 –40 490NTW00040 –80 490NTW00080 –
Shielded twisted pair cables, UL and CSA 22.1 approvedCables fitted with 2 x RJ45 connectorsfor connection to terminal equipment
Straight 2 490NTW00002U –5 490NTW00005U –12 490NTW00012U –40 490NTW00040U –80 490NTW00080U –
Ethernet Connector Elbowed 180° LTM9CE180T (3) 0.180(1) When ordering, replace the p in the reference with the number or letter required.(2) To order other connectors and cables (UL cables for harsh environments, etc.), please consult our Customer Care Centre.(3) Sold in packs of 6.
Protection componentsTeSys T Motor Management System
Presentation: pages B12/16 to B12/26
Characteristics: pages B12/27 to B12/31
Dimensions, mounting: pages B12/32 to B12/33
Schemes: pages B12/34 to B12/37
Combination for customer assembly: pages B12/38 to B12/41