26
LP 500 GENERATOR SPECIFICATION Power Rating (KVA) 500 Electric Power (KWe) 400 Rated Current (A) 695 Output voltage (V) 415 Frequency (Hz) 50 Power factor (lag) 0.8 No of Phases 3 System Voltage (VDC) 24 Dimensions (L X W X H, mm x mm x mm) 5500 x 2000 x 2235 Open Set including panel stand & W/O Silencer (mm x mm x mm) 4000 x 1800 x 2200 ENGINE SPECIFICATION Make Perkins UK Model 2506A-E15TAG2 Engine Output Prime Net (Kwm / bhp) 435 / 583 Engine Output Prime Gross (Kwm / bhp) 451 / 605 Aspiration Turbocharged charge-cooled No of Cylinder 6 Verticle Inline Rated speed (RPM) 1500 Bore & stroke (mm x mm) 137 x 171 Compression ratio 16:1 Displacement (Litres) 15.2 Dry weight of Engine (kg) 1633 Exhaust Temperature (ºC) 550 Gross break mean effective pressure (kpa) 2405 Governor/class Electronic Cooling system Water cooled

Upload: phamlien

Post on 07-Mar-2018

223 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

LP 500

GENERATOR SPECIFICATION

Power Rating (KVA) 500

Electric Power (KWe) 400

Rated Current (A) 695

Output voltage (V) 415

Frequency (Hz) 50

Power factor (lag) 0.8

No of Phases 3

System Voltage (VDC) 24

Dimensions (L X W X H, mm x mm x mm) 5500 x 2000 x 2235

Open Set including panel stand & W/O Silencer (mm x mm x mm)

4000 x 1800 x 2200

ENGINE SPECIFICATION

Make Perkins UK

Model 2506A-E15TAG2

Engine Output Prime Net (Kwm / bhp) 435 / 583

Engine Output Prime Gross (Kwm / bhp) 451 / 605

Aspiration Turbocharged charge-cooled

No of Cylinder 6 Verticle Inline

Rated speed (RPM) 1500

Bore & stroke (mm x mm) 137 x 171

Compression ratio 16:1

Displacement (Litres) 15.2

Dry weight of Engine (kg) 1633

Exhaust Temperature (ºC) 550

Gross break mean effective pressure (kpa) 2405

Governor/class Electronic

Cooling system Water cooled

Page 2: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Radiator Cu Brass with Charge Air cooler

Lub oil specs 15 W 40 CF 4

Lub oil sump capacity Max (Litres) 53

Lub oil sump capacity Min (Litres) 45

Typical lub oil consumption 0.10%

Total coolant capacity (Litres) 58

System Voltage (DC) 24

Battery capacity/rating 150 AH, (12v DC X 2 Nos)

Fuel Consumption 75% (g/KWh) 201

Fuel Consumption 100% (g/kWh) 199

Fuel Consumption @ 75 % load with Fan & charging alternator (Lit/Hr)**

76

Fuel Consumption 100% (Lit/Hr) 100

** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP

condition, Tolerance will be +5%

ALTERNATOR SPECIFICATION

Make Stamford*

Frame size/model No. HCI544D1

Voltage regulation ± 0.5 %

Class of insulation Class H

Standard Enclosure IP 23

Winding Pitch 2/3

Telephonic Interference Factor Better than 50

Efficiency 94.8

Total Harmonic Factor Better Than 2%

SPECIFICATION FOR STANDARD MANUAL PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR 3pole MCB / MCCB

Controller used for start stop panel & MAN panel • Display

Page 3: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

DSE 6010 & 6020

• Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running status

• Electrical parameters - Voltage, current, Hz, KW, KVA, Pf, kWh

Digital Multifunction meter Voltage/Ampere/Frequency

Fault Indication (LED Type on Engine safety Unit)

• Low Oil pressure

• Battery Charger Failure

• High Engine Temperature

• Low fuel level

Current Transformers of suitable rating

Indications (LED):

• DG ON

• Load on DG

Control Key switch for Start/Stop

SPECIFICATION FOR STANDARD AMF PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR

• 4 Pole Contactor for DG

• 4 Pole Contactor for MAINS

• MCCB for short circuit protection

Features • Supports Engine equipped with electronic control unit

• Graphic back lit LCD Display

• Supervision of Mains and DG voltage

• Mains and DG contactor interlock

• Provision for Remote start / stop

• Over / under voltage protection

• Over / under frequency protection

Page 4: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

• Current / voltage asymmetry

• Over current protection

• Parameter setting by front panel key board

• Auto / Manual mode operation

• Programmable parameters / timers

• Configurable input and outputs

• Alarm history

• Displays Voltage, Current, frequency, PF, kW, kWH

• Displays engine parameters like Oil pressure, coolant temperature, Engine RPM, fuel consumption, Engine running hours

• Indication LED for Mains ok, Load on Mains, DG set running, Load on Dg set

Multifunction meter

• Voltage

• Ampere

• Frequency

Analogue meter

• Oil pressure

• Water Temperature

• Engine RPM

Indication Lamps

• Mains On

• DG On

• Load on Mains

• Load on DG

SMPS based battery charger with float boost charging.

Manual mode controls • DG start

Page 5: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

• DG stop

• Load transfer

POWER RATING

Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528

Reference condition (Dec C Ambient Temp) 27

Atmospheric Condition (KPA -750mm of Hg) 100

Humidity 60% - As per IS10002, ISO 3046

LP 725

GENERATOR SPECIFICATION

Power Rating (KVA) 725

Electric Power (KWe) 580

Rated Current (A) 1008

Output voltage (V) 415

Frequency (Hz) 50

Power factor (lag) 0.8

No of Phases 3

System Voltage (VDC) 24

Dimensions (L X W X H, mm x mm x mm) 7500 x 2500 x 2930

Open Set including panel stand & W/O Silencer (mm x mm x mm)

4000 x 1800 x 2400

ENGINE SPECIFICATION

Make Perkins UK

Model 4006-23TAG2A

Engine Output Prime Net (Kwm / bhp) 632 / 847

Engine Output Prime Gross (Kwm / bhp) 658 / 882

Aspiration Turbocharged charge-cooled

No of Cylinder 6 Verticle Inline

Page 6: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Rated speed (RPM) 1500

Bore & stroke (mm x mm) 160 x 190

Compression ratio 13.6:1

Displacement (Litres) 22.92

Dry weight of Engine (kg) 2524

Exhaust Temperature (ºC) 430

Gross break mean effective pressure (kpa) 2247

Governor/class Electronic

Cooling system Water cooled

Radiator Cu Brass with Charge Air cooler

Lub oil specs 15 W 40 CF 4

Lub oil sump capacity Max (Litres) 113.4

Lub oil sump capacity Min (Litres) 90.7

Typical lub oil consumption 0.25%

Total coolant capacity (Litres) 105

System Voltage (DC) 24

Battery capacity/rating 150 AH, (12v DC X 2 Nos)

Fuel Consumption 75% (g/KWh) 211

Fuel Consumption 100% (g/kWh) 209

Fuel Consumption @ 75 % load with Fan & charging alternator (Lit/Hr)**

121

Fuel Consumption 100% (Lit/Hr) 157

** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP

condition, Tolerance will be +5%

ALTERNATOR SPECIFICATION

Make Stamford*

Frame size/model No. HCI634W1

Voltage regulation ± 0.5%

Class of insulation Class H

Page 7: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Standard Enclosure IP 23

Winding Pitch 2/3

Telephonic Interference Factor Better than 50

Efficiency 94.6

Total Harmonic Factor Better Than 2%

SPECIFICATION FOR STANDARD MANUAL PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR 3pole MCB / MCCB

Controller used for start stop panel & MAN panel DSE 6010 & 6020

• Display

• Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running status

• Electrical parameters - Voltage, current, Hz, KW, KVA, Pf, kWh

Digital Multifunction meter Voltage/Ampere/Frequency

Fault Indication (LED Type on Engine safety Unit)

• Low Oil pressure

• Battery Charger Failure

• High Engine Temperature

• Low fuel level

Current Transformers of suitable rating

Indications (LED):

• DG ON

• Load on DG

Control Key switch for Start/Stop

SPECIFICATION FOR STANDARD AMF PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR • 4 Pole Contactor for DG

• 4 Pole Contactor for MAINS

Page 8: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

• MCCB for short circuit protection

Features

• Supports Engine equipped with electronic control unit

• Graphic back lit LCD Display

• Supervision of Mains and DG voltage

• Mains and DG contactor interlock

• Provision for Remote start / stop

• Over / under voltage protection

• Over / under frequency protection

• Current / voltage asymmetry

• Over current protection

• Parameter setting by front panel key board

• Auto / Manual mode operation

• Programmable parameters / timers

• Configurable input and outputs

• Alarm history

• Displays Voltage, Current, frequency, PF, kW, kWH

• Displays engine parameters like Oil pressure, coolant temperature, Engine RPM, fuel consumption, Engine running hours

• Indication LED for Mains ok, Load on Mains, DG set running, Load on Dg set

Multifunction meter • Voltage

• Ampere

• Frequency

Page 9: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Analogue meter

• Oil pressure

• Water Temperature

• Engine RPM

Indication Lamps

• Mains On

• DG On

• Load on Mains

• Load on DG

SMPS based battery charger with float boost charging.

Manual mode controls

• DG start

• DG stop

• Load transfer

POWER RATING

Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528

Reference condition (Dec C Ambient Temp) 27

Atmospheric Condition (KPA -750mm of Hg) 100

Humidity 60% - As per IS10002, ISO 3046

LP 1010

GENERATOR SPECIFICATION

Power Rating (KVA) 1010

Electric Power (KWe) 808

Rated Current (A) 1403.9

Output voltage (V) 415

Frequency (Hz) 50

Power factor (lag) 0.8

No of Phases 3

System Voltage (VDC) 24

Page 10: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Dimensions (L X W X H, mm x mm x mm) -

Open Set including panel stand & W/O Silencer (mm x mm x mm)

5300 x 2000 x 2700

ENGINE SPECIFICATION

Make Perkins UK

Model 4008 TAG2A

Engine Output Prime Net (Kwm / bhp) 861 / 1155

Engine Output Prime Gross (Kwm / bhp) 899 / 1206

Aspiration Turbocharged charge-cooled

No of Cylinder 8 Inline

Rated speed (RPM) 1500

Bore & stroke (mm x mm) 160 x 190

Compression ratio 13.6:1

Displacement (Litres) 30.56

Dry weight of Engine (kg) 4270

Exhaust Temperature (ºC) 438

Gross break mean effective pressure (kpa) 2320

Governor/class Electronic

Cooling system Water cooled

Radiator Cu Brass with Charge Air cooler

Lub oil specs 15 W 40 CF 4

Lub oil sump capacity Max (Litres) 153

Lub oil sump capacity Min (Litres) 127

Typical lub oil consumption (g/kwH) 0.52

Total coolant capacity (Litres) 149

System Voltage (DC) 24

Battery capacity/rating 180 AH, (12v DC x 2 Nos)

Fuel Consumption 75% (g/KWh) 202

Page 11: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Fuel Consumption 100% (g/kWh) 208

Fuel Consumption @ 75 % load with Fan & charging alternator (Lit/Hr)**

160

Fuel Consumption 100% (Lit/Hr) 220

** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP

condition, Tolerance will be +5%

ALTERNATOR SPECIFICATION

Make Stamford*

Frame size/model No. HCI634Y1

Voltage regulation ± 0.5%

Class of insulation Class H

Standard Enclosure IP 23

Winding Pitch 2/3

Telephonic Interference Factor Better than 50

Efficiency 95.3

Total Harmonic Factor Better Than 2%

SPECIFICATION FOR STANDARD MANUAL PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR 3pole MCB / MCCB

Controller used for start stop panel & MAN panel DSE 6010 & 6020

• Display

• Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running status

• Electrical parameters - Voltage, current, Hz, KW, KVA, Pf, kWh

Digital Multifunction meter Voltage/Ampere/Frequency

Fault Indication (LED Type on Engine safety Unit) • Low Oil pressure

• Battery Charger Failure

• High Engine Temperature

Page 12: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

• Low fuel level

Current Transformers of suitable rating

Indications (LED):

• DG ON

• Load on DG

Control Key switch for Start/Stop

SPECIFICATION FOR STANDARD AMF PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR

• 4 Pole Contactor for DG

• 4 Pole Contactor for MAINS

• MCCB for short circuit protection

Features • Supports Engine equipped with electronic control unit

• Graphic back lit LCD Display

• Supervision of Mains and DG voltage

• Mains and DG contactor interlock

• Provision for Remote start / stop

• Over / under voltage protection

• Over / under frequency protection

• Current / voltage asymmetry

• Over current protection

• Parameter setting by front panel key board

• Auto / Manual mode operation

• Programmable parameters / timers

• Configurable input and outputs

• Alarm history

Page 13: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

• Displays Voltage, Current, frequency, PF, kW, kWH

• Displays engine parameters like Oil pressure, coolant temperature, Engine RPM, fuel consumption, Engine running hours

• Indication LED for Mains ok, Load on Mains, DG set running, Load on Dg set

Multifunction meter

• Voltage

• Ampere

• Frequency

Analogue meter

• Oil pressure

• Water Temperature

• Engine RPM

Indication Lamps

• Mains On

• DG On

• Load on Mains

• Load on DG

SMPS based battery charger with float boost charging.

Manual mode controls

• DG start

• DG stop

• Load transfer

POWER RATING

Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528

Reference condition (Dec C Ambient Temp) 27

Atmospheric Condition (KPA - 750mm of Hg) 100

Humidity 60% - As per IS10002, ISO 3046

Page 14: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

LP 1250

GENERATOR SPECIFICATION

Power Rating (KVA) 1500

Electric Power (KWe) 1200

Rated Current (A) 2085

Output voltage (V) 415

Frequency (Hz) 50

Power factor (lag) 0.8

No of Phases 3

System Voltage (VDC) 24

Dimensions (L X W X H, mm x mm x mm) -

Open Set including panel stand & W/O Silencer (mm x mm x mm)

5300 x 2000 x 2800

ENGINE SPECIFICATION

Make Perkins UK

Model 4012-46TAG0A

Engine Output Prime Net (Kwm / bhp) 1053 / 1412

Engine Output Prime Gross (Kwm / bhp) 1117 / 1497

Aspiration Turbocharged charge-cooled

No of Cylinder 12 'Vee'

Rated speed (RPM) 1500

Bore & stroke (mm x mm) 160 x 190

Compression ratio 13.6:1

Displacement (Litres) 45.84

Dry weight of Engine (kg) 6086

Exhaust Temperature (ºC) 425

Gross break mean effective pressure (kpa) 1949

Governor/class Electronic

Cooling system Water cooled

Page 15: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Radiator Cu Brass with Charge Air cooler

Lub oil specs 15 W 40 CF 4

Lub oil sump capacity Max (Litres) 159

Lub oil sump capacity Min (Litres) 136

Typical lub oil consumption (g/kwH) 0.52

Total coolant capacity (Litres) 210

System Voltage (DC) 24

Battery capacity/rating 180 AH, (12v DC x 4 Nos)

Fuel Consumption 75% (g/KWh) 204

Fuel Consumption 100% (g/kWh) 199

Fuel Consumption @ 75 % load with Fan & charging alternator (Lit/Hr)**

199

Fuel Consumption 100% (Lit/Hr) 259

** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP

condition, Tolerance will be +5%

ALTERNATOR SPECIFICATION

Make Stamford*

Frame size/model No. PI734B1

Voltage regulation ± 0.5%

Class of insulation Class H

Standard Enclosure IP 23

Winding Pitch 2/3

Telephonic Interference Factor Better than 50

Efficiency 95

Total Harmonic Factor Better Than 2%

SPECIFICATION FOR STANDARD MANUAL PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR 3pole MCB / MCCB

Controller used for start stop panel & MAN panel • Display

Page 16: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

DSE 6010 & 6020

• Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running status

• Electrical parameters - Voltage, current, Hz, KW, KVA, Pf, kWh

Digital Multifunction meter Voltage/Ampere/Frequency

Fault Indication (LED Type on Engine safety Unit)

• Low Oil pressure

• Battery Charger Failure

• High Engine Temperature

• Low fuel level

Current Transformers of suitable rating

Indications (LED):

• DG ON

• Load on DG

Control Key switch for Start/Stop

SPECIFICATION FOR STANDARD AMF PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR

• 4 Pole Contactor for DG

• 4 Pole Contactor for MAINS

• MCCB for short circuit protection

Features • Supports Engine equipped with electronic control unit

• Graphic back lit LCD Display

• Supervision of Mains and DG voltage

• Mains and DG contactor interlock

• Provision for Remote start / stop

• Over / under voltage protection

Page 17: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

• Over / under frequency protection

• Current / voltage asymmetry

• Over current protection

• Parameter setting by front panel key board

• Auto / Manual mode operation

• Programmable parameters / timers

• Configurable input and outputs

• Alarm history

• Displays Voltage, Current, frequency, PF, kW, kWH

• Displays engine parameters like Oil pressure, coolant temperature, Engine RPM, fuel consumption, Engine running hours

• Indication LED for Mains ok, Load on Mains, DG set running, Load on Dg set

Multifunction meter

• Voltage

• Ampere

• Frequency

Analogue meter

• Oil pressure

• Water Temperature

• Engine RPM

Indication Lamps

• Mains On

• DG On

• Load on Mains

• Load on DG

SMPS based battery charger with float boost charging.

Page 18: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Manual mode controls

• DG start

• DG stop

• Load transfer

POWER RATING

Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528

Reference condition (Dec C Ambient Temp) 27

Atmospheric Condition (KPA-750mm of Hg) 100

Humidity 60% - As per IS10002, ISO 3046

LP 1500GENERATOR SPECIFICATION

Power Rating (KVA) 1500

Electric Power (KWe) 1200

Rated Current (A) 2085

Output voltage (V) 415

Frequency (Hz) 50

Power factor (lag) 0.8

No of Phases 3

System Voltage (VDC) 24

Dimensions (L X W X H, mm x mm x mm) -

Open Set including panel stand & W/O Silencer (mm x mm x mm)

5300 x 2000 x 2800

ENGINE SPECIFICATION

Make Perkins UK

Model 4012TAG2A

Engine Output Prime Net (Kwm / bhp) 1267 / 1700

Engine Output Prime Gross (Kwm / bhp) 1309 / 1756

Aspiration Turbocharged charge-cooled

No of Cylinder 12 'Vee'

Page 19: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Rated speed (RPM) 1500

Bore & stroke (mm x mm) 160 x 190

Compression ratio 13.6:1

Displacement (Litres) 45.84

Dry weight of Engine (kg) 6026

Exhaust Temperature (ºC) 490

Gross break mean effective pressure (kpa) 2260

Governor/class Electronic

Cooling system Water cooled

Radiator Cu Brass with Charge Air cooler

Lub oil specs 15 W 40 CF 4

Lub oil sump capacity Max (Litres) 159

Lub oil sump capacity Min (Litres) 136

Typical lub oil consumption (g/kwH) 0.52

Total coolant capacity (Litres) 210

System Voltage (DC) 24

Battery capacity/rating 180 AH, (12v DC x 4 Nos)

Fuel Consumption 75% (g/KWh) 202

Fuel Consumption 100% (g/kWh) 203

Fuel Consumption @ 75 % load with Fan & charging alternator (Lit/Hr)**

231

Fuel Consumption 100% (Lit/Hr) 309

** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP

condition, Tolerance will be +5%

ALTERNATOR SPECIFICATION

Make Stamford*

Frame size/model No. P1734C1

Voltage regulation ± 0.5%

Class of insulation Class H

Page 20: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Standard Enclosure IP 23

Winding Pitch 2/3

Telephonic Interference Factor Better than 50

Efficiency 95.5

Total Harmonic Factor Better Than 2%

SPECIFICATION FOR STANDARD MANUAL PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR 3pole MCB / MCCB

Controller used for start stop panel & MAN panel DSE 6010 & 6020

• Display

• Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running status

• Electrical parameters - Voltage, current, Hz, KW, KVA, Pf, kWh

Digital Multifunction meter Voltage/Ampere/Frequency

Fault Indication (LED Type on Engine safety Unit)

• Low Oil pressure

• Battery Charger Failure

• High Engine Temperature

• Low fuel level

Current Transformers of suitable rating

Indications (LED):

• DG ON

• Load on DG

Control Key switch for Start/Stop

SPECIFICATION FOR STANDARD AMF PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR • 4 Pole Contactor for DG

• 4 Pole Contactor for MAINS

Page 21: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

• MCCB for short circuit protection

Features

• Supports Engine equipped with electronic control unit

• Graphic back lit LCD Display

• Supervision of Mains and DG voltage

• Mains and DG contactor interlock

• Provision for Remote start / stop

• Over / under voltage protection

• Over / under frequency protection

• Current / voltage asymmetry

• Over current protection

• Parameter setting by front panel key board

• Auto / Manual mode operation

• Programmable parameters / timers

• Configurable input and outputs

• Alarm history

• Displays Voltage, Current, frequency, PF, kW, kWH

• Displays engine parameters like Oil pressure, coolant temperature, Engine RPM, fuel consumption, Engine running hours

• Indication LED for Mains ok, Load on Mains, DG set running, Load on Dg set

Multifunction meter • Voltage

• Ampere

• Frequency

Page 22: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Analogue meter

• Oil pressure

• Water Temperature

• Engine RPM

Indication Lamps

• Mains On

• DG On

• Load on Mains

• Load on DG

SMPS based battery charger with float boost charging.

Manual mode controls

• DG start

• DG stop

• Load transfer

POWER RATING

Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528

Reference condition (Dec C Ambient Temp) 27

Atmospheric Condition (KPA-750mm of Hg) 100

Humidity 60% - As per IS10002, ISO 3046

LP 2000

GENERATOR SPECIFICATION

Power Rating (KVA) 2000

Electric Power (KWe) 1600

Rated Current (A) 2780

Output voltage (V) 415

Frequency (Hz) 50

Power factor (lag) 0.8

No of Phases 3

System Voltage (VDC) 24

Page 23: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Dimensions (L X W X H, mm x mm x mm) -

Open Set including panel stand & W/O Silencer (mm x mm x mm)

6150 x 2300 x 3800

ENGINE SPECIFICATION

Make Perkins UK

Model 4016TAG2A

Engine Output Prime Net (Kwm / bhp) 1715 / 2300

Engine Output Prime Gross (Kwm / bhp) 1766 / 2367

Aspiration Turbocharged charge-cooled

No of Cylinder 16 'Vee'

Rated speed (RPM) 1500

Bore & stroke (mm x mm) 160 x 190

Compression ratio 13.6:1

Displacement (Litres) 61.12

Dry weight of Engine (kg) 8010

Exhaust Temperature (ºC) 493

Gross break mean effective pressure (kpa) 2310

Governor/class Electronic

Cooling system Water cooled

Radiator Cu Brass with Charge Air cooler

Lub oil specs 15 W 40 CF 4

Lub oil sump capacity Max (Litres) 214

Lub oil sump capacity Min (Litres) 147

Typical lub oil consumption (g/kwH) 0.52

Total coolant capacity (Litres) 316

System Voltage (DC) 24

Battery capacity/rating 180 AH, (12v DC x 4 Nos)

Fuel Consumption 75% (g/KWh) 209

Page 24: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

Fuel Consumption 100% (g/kWh) 213

Fuel Consumption @ 75 % load with Fan & charging alternator (Lit/Hr)**

326

Fuel Consumption 100% (Lit/Hr) 447

** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP

condition, Tolerance will be +5%

ALTERNATOR SPECIFICATION

Make Stamford*

Frame size/model No. PI734F1

Voltage regulation ± 0.5%

Class of insulation Class H

Standard Enclosure IP 23

Winding Pitch 2/3

Telephonic Interference Factor Better than 50

Efficiency 96

Total Harmonic Factor Better Than 2%

SPECIFICATION FOR STANDARD MANUAL PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR 3pole MCB / MCCB

Controller used for start stop panel & MAN panel DSE 6010 & 6020

• Display

• Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running status

• Electrical parameters - Voltage, current, Hz, KW, KVA, Pf, kWh

Digital Multifunction meter Voltage/Ampere/Frequency

Fault Indication (LED Type on Engine safety Unit) • Low Oil pressure

• Battery Charger Failure

• High Engine Temperature

Page 25: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

• Low fuel level

Current Transformers of suitable rating

Indications (LED):

• DG ON

• Load on DG

Control Key switch for Start/Stop

SPECIFICATION FOR STANDARD AMF PANEL

Cubical type made of CRCA sheet, Powder coated, mounted inside canopy with hinged type doors

SWITCH GEAR

• 4 Pole Contactor for DG

• 4 Pole Contactor for MAINS

• MCCB for short circuit protection

Features • Supports Engine equipped with electronic control unit

• Graphic back lit LCD Display

• Supervision of Mains and DG voltage

• Mains and DG contactor interlock

• Provision for Remote start / stop

• Over / under voltage protection

• Over / under frequency protection

• Current / voltage asymmetry

• Over current protection

• Parameter setting by front panel key board

• Auto / Manual mode operation

• Programmable parameters / timers

• Configurable input and outputs

• Alarm history

Page 26: LP 500 - 2.imimg.com2.imimg.com/data2/WR/KG/MY-3414022/lp-500-2000kva.pdfDSE 6010 & 6020 • Engine Parameters - RPM, Oil Presssure, coolant temprature Hour Meter, battery volt, running

• Displays Voltage, Current, frequency, PF, kW, kWH

• Displays engine parameters like Oil pressure, coolant temperature, Engine RPM, fuel consumption, Engine running hours

• Indication LED for Mains ok, Load on Mains, DG set running, Load on Dg set

Multifunction meter

• Voltage

• Ampere

• Frequency

Analogue meter

• Oil pressure

• Water Temperature

• Engine RPM

Indication Lamps

• Mains On

• DG On

• Load on Mains

• Load on DG

SMPS based battery charger with float boost charging.

Manual mode controls

• DG start

• DG stop

• Load transfer

POWER RATING

Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528

Reference condition (Dec C Ambient Temp) 27

Atmospheric Condition (KPA-750mm of Hg) 100

Humidity 60% - As per IS10002, ISO 3046