  • A Larsen & Toubro Group Company

  • For Power Distribution

  • TRADITIONAL Cable SystemMV SupplyMV PanelLV SupplyLV PanelLoad Centers

  • Short comings of TRADITIONAL Cable System*As per data, in year 2012, 56% of accidents in industries is because of electrical system failure/short circuits in cables.Courtesy: Wordpress# Heat, Fire & Safety# Short Circuit withstand capacity# Energy Efficiency# Flexibility# Installation# Service life# Space requirement

  • Busbar Trunking SystemDefinitionBusbar Trunking System is a prefabricated electrical distribution system consisting of busbars in a protective enclosure, including straight lengths, fittings, devices and accessories.Mainly of two types:Air Insulated SandwichAir -InsulatedSandwich

  • Busbar Trunking SystemMV SupplyMV PanelLV SupplyLV PanelLoad CentersBack-up Supply

  • Advantages of Busbar Trunking System*Busbar Trunking System is highly recommended, adopted and consulted by many consultants and become a integral part of Green Building ConceptSupported By: Electrical Times (UK), Modern Building Services (UK), ESDS (India), Electrical Engineering Portal# Heat , Fire & Safety# Short Circuit withstand capacity# Energy Efficiency# Flexibility# Installation# Service life# Space requirement

  • *There are 4 classes of fire:Class AOrdinary combustibles or fibrous material, such as wood, paper, cloth, rubber, and some plastics.Class BFlammable or combustible liquids such as gasoline, kerosene, paint, paint thinners and propane.Class CEnergized electrical equipment, such as appliances, switches, panel boxes and power tools.Class DCertain combustible metals, such as magnesium, titanium, potassium, and sodium. Heat , Fire & Safety

  • *

    Energized Electrical Equipment Bus ductHeat , Fire & SafetyHeat : Increased temperature of conductor can lead to fire in case of poor insulationMost common Insulations used in sandwich Bus Bar Trunking system: Note : Use of Class F insulation or Class H insulation can increase the service factor or the ability to withstand high ambient temperature conditions.

    Class B130 C - This has a form that inorganic material is hardened with adhesives Eg. Mica.Class F155 C Made of Class-B materials that are upgraded with adhesives, silicone, and alkyd-resin varnish of higher thermal endurance. Eg. - Combination of Mylar & Nomex Class - H180 C Made of inorganic material glued with silicone resin or adhesives of equivalent performance Eg. Epoxy.

  • *

    Epoxy Insulation compound - HKE 455Various grades of epoxy compound when mixed in different combination give different results,

    Our Epoxy HKE 455 is a compound ( In House ) made from polymeric component , chlorine, carbon, calcium, silicon and aluminium.

    High with stand capacity : 10000 volts / layer,

    Very high tensile strength : 23000 psi

    Excellent resistance to most chemicals & moisture,

    High flexibility for temperature extremes : - 5C to 180 C

    Does not become brittle with age.

    Class F insulation 155 C Ref. Ambient of 40C + Allowable temp. Rise 105C + Allowance for Hot spot of 10C Example : 40 oC + 105 oC + 10 oC = 155 oC

  • *

    7. Life of epoxy compound is more than 25 years.

    8. No corona effect due to extrusion process used for insulating conductors

    9. Any possible problems due to pin-holes is prevented at QC by passing each piece through a 5kV HV test for 60Sec.

    10. Each and every single piece is tested for 5kV (60Sec) as part of routine test prior to dispatch clearance.

    11. RoHS compliant.

  • One-on-One ComparisonSupported By: 100s of articles/papers in IEEE Explorer, 10s of articles and papers in ScienceDirect and very famous Wiki

    FactorsTraditional CableMODERN Busbar TrunkingTechnical ComparisonEnergy EfficiencyLowHighVoltage dropSafety FeaturesLessMoreSC withstand capacity (25kA to 100+kA), Protection against fire, Combustive energy (80%less than cable)Service LifeLowHighAverage service life is >20 yearsFlexibility to RequirementsNoYesLoad can be added and adjusted on the existing systemInstallation CostHighLowShorter installation time, less support and space required (30% saving)AestheticPoorGoodCompact in size and well finished surfaceSpace RequiredLargeSmallSingle run for multiple circuitsMechanical StrengthLowHighMetal EnclosureInvestment on MaterialLowHighPayback period of avg. 1 years

  • Areas of application

  • Busbar Trunking SystemHenikwon

    SpecificationOptionTypeAir-Insulated or SandwichVoltage Level415V, 690V or 1000VAmpere Rating400A to 6300AConductorAluminium & CopperPhase Combination3P with 50%N or 100%N or 200%N with/without internal EarthIngress ProtectionIP-42, IP-54, IP-55, IP-65, IP-66, IP-67 and IP-68InsulationAir or Polymer or EpoxyEnclosureGI or AluminiumShort Circuit Withstand Capacity25kA to 100kAPower Frequency Withstand Voltage2.5kV for 1 min.

    HenikwonSandwichMax. Up-to 1000V400A to 6300AAluminium & CopperAllIP-54, IP-55, IP-67 and IP-68Epoxy CompoundGI and Aluminium25kA to 100kA3.5kV for 1 min.

  • Compact Sandwich constructionNO Chimney effect ( Stack Effect)Robust Construction (2 piece enclosure)Certified for fire propagation test as per standard IEC-60439Design for 50 Deg. C ambient temperatureADVANTAGES Henikwon Busbar Trunking SystemIngress Protection LevelIP-54 and IP-55 for IndoorIP-67 and IP-68 for complete OutdoorCertified as per standards IEC-60529Epoxy Compound InsulationNon-HygroscopicFire ResistantBetter heat conductivityBetter thermal expansion and contraction coefficientInsulation through automated processDirect Contact JointBetter operating temperatureLess power loss at jointsSingle bolt joint with maintenance free nut

  • A look at Direct Contact Joint SystemHENIKWON Busbar Trunking System

  • FIRE PROPAGATION TEST BY ASTAHENIKWON BUSDUCT SYSTEM UNDER ASTA TYPE TESTTesting for Fire propagationHENIKWON Busbar Trunking SystemFire Rated Busduct-Henikwon is the worlds first busduct system tested for fire rating.-Tested for 3 Hrs @ 750 Deg. C

  • Busbar Trunking System ComponentsStraight Length Feeder TypeStraight Length Plug-in TypeFlatwise ElbowEdgewise ElbowHENIKWON Busbar Trunking System

  • Sandwich Busbar Trunking System ComponentsEdgewise OffsetFlatwise OffsetReducerPlug-in BoxFlange EndCombination ElbowHENIKWON Busbar Trunking System

  • Plug-in BoxStraight LengthFlatwise ElbowEdgewise ElbowCentre-Feed BoxEnd-Feed BoxHENIKWON Busbar Trunking SystemConventional Busbar Trunking System:- Up-to Maximum 415 V- 100 A to 400 A Current Capacity- Air-Insulated Non-Segregated Type

  • Straight LengthFlatwise ElbowEdgewise ElbowPhase Transposition BoxHENIKWON Busbar Trunking SystemMedium Voltage Busbar Trunking System:- Up-to Maximum 33 kV and- 400 A to 5000 A Current Capacity- Non-Segregated Type Air-insulated

  • Reference Standards Low Voltage SystemIEC 60439-1&2:2005IEC 61439-6BS EN 60439-1&2:2000AS NZ 3439-2: 2002AS 3439-2:1994JISC 8364Medium Voltage SystemIEC 62271-200:2003VDE 532IP ProtectionIEC 60529-2:2001AS 60529: 2004Fire SafetyIEC 60331

  • In use at more than 900 Installations 25 countries spread across 5 continentsIndiaJaypee Greens (NOIDA), TATA Software Park (Mumbai), Intel (Bangalore), Godrej Towers (Mumbai), Hyundai Motors (Chennai), Dell (Bangalore), HSBC (Hyderabad), Wipro (Hyderabad), Sahara (Gurgaon), TCS (Kolkata), Weinker Institute (Mumbai), Veneberg Park (Hyderabad), DMRC (New Delhi), SSG (Chennai), HSBC (Kolkata), International School (Bangalore), MTNL (New Delhi), etc.OverseasLagos (UK), Churchill Tower (UAE), HP Global IT Hub (Malaysia), Aseeb Waste Water Plant (Oman), Mahreq Bank (UAE), Hotel Panghegar (Indonesia), HB Tower (Vietnam), Bio-Mass Power Plant (Malaysia), Alhamra Palace (UAE), Gate Hampton (UK), Wan Chai Police HQ (Japan), Petro-sport (Egypt), 62 CCE Pacifico (Mexico), etc.Project References