Lund University Lund
Skåne
Sweden
Ulf Mjörnmark
Status and plans
JRA2TPC DAQ
![Page 2: Lund University Lund JRA2 TPC DAQfrom RCU/TLU/DAQPC busy logic: trigger sets system busy busy reset either: 1) DAQPC via ethernet 2) Fixed time in distributor box Cables. TEST SETUP](https://reader033.vdocument.in/reader033/viewer/2022060522/6051e6c34ee2960b35065d61/html5/thumbnails/2.jpg)
TPC local trigger
TPC
RCU
back
plane
25cm FECData in/out200MB/s2 fibres
Distrbox40MHz
clk
lvl1
busy
2048ch,16 FEC
close
BUSy
Trigger +event #
TLUMainDAQ
CLk
metersaway
clk
busy
Trigger +event #
Other subsys daq
ethernet
![Page 3: Lund University Lund JRA2 TPC DAQfrom RCU/TLU/DAQPC busy logic: trigger sets system busy busy reset either: 1) DAQPC via ethernet 2) Fixed time in distributor box Cables. TEST SETUP](https://reader033.vdocument.in/reader033/viewer/2022060522/6051e6c34ee2960b35065d61/html5/thumbnails/3.jpg)
Based on the ALICE TPC readout:Front End Card (FEC), to be modified for new amplifierReadout Control Unit (RCU), modified for clock/trigger/25Mhz sample clockSource Interface Unit (SIU)Read Out Receiver Card (DRORC), Destination Interface Unit (DIU)ALICE API/driversBuild our own DAQ on topDistributor Box (DBOX) to distribute clock/trigger/busyInterface to common DAQ
EUDET: 1 RCU10000 ch: 4 RCUpossible to distribute 1 RCU system
![Page 4: Lund University Lund JRA2 TPC DAQfrom RCU/TLU/DAQPC busy logic: trigger sets system busy busy reset either: 1) DAQPC via ethernet 2) Fixed time in distributor box Cables. TEST SETUP](https://reader033.vdocument.in/reader033/viewer/2022060522/6051e6c34ee2960b35065d61/html5/thumbnails/4.jpg)
Hardware overviewFrontEndCardReadoutControlUnitReadOutReceivrCardDistributorBOX
![Page 5: Lund University Lund JRA2 TPC DAQfrom RCU/TLU/DAQPC busy logic: trigger sets system busy busy reset either: 1) DAQPC via ethernet 2) Fixed time in distributor box Cables. TEST SETUP](https://reader033.vdocument.in/reader033/viewer/2022060522/6051e6c34ee2960b35065d61/html5/thumbnails/5.jpg)
19 cm
17 c
m
ALICE TPC Front End Card
ALTRO 16 ch ADC
PASA to be raplced with
Programmable Charge Amplifier (PCA16)
![Page 6: Lund University Lund JRA2 TPC DAQfrom RCU/TLU/DAQPC busy logic: trigger sets system busy busy reset either: 1) DAQPC via ethernet 2) Fixed time in distributor box Cables. TEST SETUP](https://reader033.vdocument.in/reader033/viewer/2022060522/6051e6c34ee2960b35065d61/html5/thumbnails/6.jpg)
Trigger/Busy system
Ethernet
ALTRO bus
synchronization:compare event numbercompare time stampsfrom RCU/TLU/DAQPC
busy logic:trigger sets system busybusy reset either:1) DAQPC via ethernet2) Fixed time in distributor box
Cables
![Page 7: Lund University Lund JRA2 TPC DAQfrom RCU/TLU/DAQPC busy logic: trigger sets system busy busy reset either: 1) DAQPC via ethernet 2) Fixed time in distributor box Cables. TEST SETUP](https://reader033.vdocument.in/reader033/viewer/2022060522/6051e6c34ee2960b35065d61/html5/thumbnails/7.jpg)
TEST SETUP
DRORC
Optical fiberALICE FECBackplane
RCU
Trigger
Power
Pulser
Busy/Control( Parallel port )
![Page 8: Lund University Lund JRA2 TPC DAQfrom RCU/TLU/DAQPC busy logic: trigger sets system busy busy reset either: 1) DAQPC via ethernet 2) Fixed time in distributor box Cables. TEST SETUP](https://reader033.vdocument.in/reader033/viewer/2022060522/6051e6c34ee2960b35065d61/html5/thumbnails/8.jpg)
Raw data (double pulse)
TIME = 100ns per bin (10 MHz sample clock)410 samples
AD
C v
alu
e
AD
C v
alu
e
Pedestal subtractedZero suppressed(Multiple pulses)
DATA
from
TEST
SETUP
![Page 9: Lund University Lund JRA2 TPC DAQfrom RCU/TLU/DAQPC busy logic: trigger sets system busy busy reset either: 1) DAQPC via ethernet 2) Fixed time in distributor box Cables. TEST SETUP](https://reader033.vdocument.in/reader033/viewer/2022060522/6051e6c34ee2960b35065d61/html5/thumbnails/9.jpg)
Use ALICE drivers and APIs as isBuild DAQ (readout/control) on topInterface to common DAQ
![Page 10: Lund University Lund JRA2 TPC DAQfrom RCU/TLU/DAQPC busy logic: trigger sets system busy busy reset either: 1) DAQPC via ethernet 2) Fixed time in distributor box Cables. TEST SETUP](https://reader033.vdocument.in/reader033/viewer/2022060522/6051e6c34ee2960b35065d61/html5/thumbnails/10.jpg)
SUMMARY
Based on ALICE TPC readoutNew preamplifier on front end card Using ALICE driversBuild simple DAQ on topDistributor box to distribute trigger/clock/busy
Simple test setup working
Work in progress on:front end cardsdistributor boxreadout of hardwarereadout configuration
Missing:run controlmonitoringdetector controldata transfer and format