exteriorassets2.hunterdouglascontract.com/documents/ceiling/brochures...exterior luxalon ® exterior...

32
Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended carriers ensure durability and withstand severe conditions. Allowing a wide range of design possibilities exterior ceilings are specially developed with the same aesthetic appearance as the Luxalon ® Interior Ceilings.

Upload: trinhxuyen

Post on 11-May-2018

231 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

ExteriorLuxalon® Exterior Ceilings by Hunter Douglasin special aluminium alloy attached to rigidlysuspended carriers ensure durability andwithstand severe conditions. Allowing awide range of design possibilities exteriorceilings are specially developed with thesame aesthetic appearance as the Luxalon® Interior Ceilings.

Page 2: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

ExteriorFlexible durability

A PROVEN SYSTEMHunter Douglas’ Luxalon® Exterior Ceiling system isspecially developed to withstand the strongest weatherinfluences. Tested by TNO, an independent testing andresearch institute in the Netherlands, these ceilings areguaranteed to impress with their durability and designfor many years after installation. The ceiling panels are roll formed from pre-painted, stove-enamelledaluminium strip made from an alloy that is excellent for exterior applications.

The Luxalon® Exterior Ceiling system appears in manydifferent applications including overhanging ceilings inoffice buildings and hotels, canopies in gas stations,and underpass applications in metro and railwaystations.

DESIGN FLEXIBILITYThe Luxalon® Exterior Ceiling system creates newopportunities for expressive architecture and addsbeauty and durability to any building’s exterior. Concave,convex, and undulating sections can be easily formed todesign the perfect curved ceiling. The standardLuxalon® exterior colour range features a variety ofcolours and finishes, with RAL or NCS colours deliveredon request. Some Luxalon® Exterior Ceiling systems arealso available for interior applications, allowingarchitects to visually connect the interior and exterior ofa building for an impressive, unified look.

WEATHER RESISTANCELuxalon® Exterior Ceilings are developed to withstand allweather influences including intensive sunshine,dramatic temperature changes, moisture, pollution andstrong wind loads. Their durability comes from the

Page 3: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

patented Luxacote® system, a tough coating thatguarantees colour stability and high resistance againstcorrosion and scratches. The ceilings are made with anideal corrosion-resistant aluminium and featureLuxalon® Profix, Hunter Douglas’ exterior windproofsuspension system.

EASY PLENUM ACCESSThe Luxalon® system allows for easy (de)mounting ofceiling panels. Installed on a concealed suspensionsystem, each panel and infill can be removed andreplaced by hand, allowing easy and full access toservices and installations in the plenum.

Innovative Products Make Innovative Projects

CONTENT Page

84R 2

80B, 84B 3

84C 4

75C, 150C, 225C 5

300A, C, L 6 - 7

150F, 200F 8

70U, 185U 9 - 10

V100 11

Façade systems as Ceiling application 12

Edge solutions 13

Specifications 14 - 15

Maximum Spans 16 - 25

Material Specifications 26

Impressions 27

Production byHunter DouglasCeiling Center

Page 4: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

2 HunterDouglas® Ceilings - Exterior

1

4

2

5

6

8 9a

9b

C

D

E7

A

B

B

B

11

3

10

84R

16

45

62

1618,5 38

2021 18,5

29

84

65

16

45

45

21

6284

28.6

12.5

CONSTRUCTION DETAILSCurved ceilings can be achieved by curvingthe 84R panels. See separate brochure forcurved ceilings. The system is alsoavailable for interior applications.The Luxalon® standard range of edgeprofiles can be used as perimeters.

PANELSThe Luxalon® 84R Ceiling system consistsof round edged panels (1) which can beeasily clipped on an 84R carrier (2). Panelscan be joined by using the panel splice (8).Between the panels there is an open jointof 16 mm, which can be filled with a 16 mm wide flush join profile (9a) to form aflush closed ceiling appearance or arecessed joint (9b). Join profiles can besimply inserted by hand, without using anytools.

SUSPENSIONThe panel carrier (2) is black and isprovided with prongs to accommodate thepanels in a standard module of 100 mm. Carriers have a standard length of 5000 mm. 84 16

16

Panel Width Module Min. Max. Weight panels & carriers/m2*(mm) (mm) length length Aluminium carrier

(mm) (mm) Excl joins Incl joins

84R 84 100 1000 6000 1.7 kg 2.2 kg

Unit 84R exterior system (panel + flush joint)

Panels lm 10Join profiles lm 10Carriers lm 1.25Carrier splice pcs 0.25Suspension pcs 2.13Locking clips pcs 12.5

MATERIAL REQUIREMENT PER M2

The required number of componentsdepend on individual project requirements.Figures based on a ceiling installed on 3 ormore carriers and submitted to a windload(pressure) of 1000 N/m2. For corners, roofedges, special designs etc. windpressure/suction shall be determined withdue consideration to the local country’sStandard Codes of Building Practice.

MAXIMUM SPANS See graphs on page 16.

DIMENSIONS & WEIGHTS* Based on panels installed on 3 or morecarriers. The panels are made to measurein any length up to 6000 mm.

Panels > 6000 mm available on request.

1 = 84R panel2 = carrier3 = screw washer4 = reinforcement5 = hanger6 = top fixing7 = threaded rod8 = panel splice9a = flush joint9b = recessed joint10 = locking clip11 = non-HD

A = Luxalon® Profix cantileverB = carrier spanC = panel spanD = panel cantileverE = Luxalon® Profix-carrier span

Page 5: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

3HunterDouglas® Ceilings - Exterior

See graphs on page 17 and 18.

80 20

15

84 16

12,5

3 1

4

2

5

6

8

C

D

E

A

7

9

B

B

B

11

10

Panel Width Module Min. Max. Weight panels (mm) (mm) length length &

(mm) (mm) carriers/m2*

80B 80 100 1000 6000 2.5

84B 84 100 1000 6000 1.7

Unit 80B exterior system 84B exterior system

Panels lm 10 10U-shaped join profiles lm 10 -Carriers lm 0.77 / 1.25* 0.71Carrier splice pcs 0.15 / 0.25* 0.14Suspension pcs 1.77 / 2.13* 2.13Locking clips pcs - / 12.5* 7.1* When used without joint profiles

MATERIAL REQUIREMENT PER M2

The required number of componentsdepend on individual project requirements.Figures based on a ceiling installed on 3 ormore carriers and submitted to a windload(pressure) of 1000 N/m2. For corners, roofedges, special designs etc. windpressure/suction shall be determined withdue consideration to the local country’sStandard Codes of Building Practice.

DIMENSIONS & WEIGHTS* Based on panels installed on 3 or more carriers.

Panels from 250-1000 mm and > 6000 mm are available on request.

20

15

80

29

62 2118,5 2118,5

45

21

19,5

45

62

29

8416

12,5

41,5

8416

*

18,5

21 18,5 62

38

20

65

45

45

21

62

*

28.6

12.5

CONSTRUCTION DETAILSThe 80B panels combined with join profilesprovide a visually closed ceiling.The system is also available for interiorapplications. Flexible carriers are availablein order to create a curved ceiling. Seeseparate brochure. The Luxalon® standardrange of edge profiles can be used asperimeters.

80B

84B

PANELSThe Luxalon® 80B/84B Ceiling systemconsists of box shaped, 80 mm/84 mmwide aluminium panels (1) which can beeasily clipped on the 80B/84B carrier (2).Panels can be joined by using the panelsplice (8).

Between the 80B panels there is an openjoint of 20 mm, which can be filled with arecessed U-shaped infill profile (9).Between the 84B panels there is an openjoint of 16 mm.

SUSPENSIONThe carrier (2) is black, and provided withprongs to accommodate the panels in amodule of 100 mm. Carriers have astandard length of 5000 mm.

MAXIMUM SPANS

80B, 84B

1 = 80B/84B panel2 = carrier3 = screw washer4 = reinforcement5 = hanger6 = top fixing7 = threaded rod8 = panel splice9 = joint-infill (80B only)

10 = locking clip11 = non-HD

A = Luxalon® Profix cantileverB = carrier spanC = panel spanD = panel cantileverE = Luxalon® Profix-carrier span

Page 6: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

4 HunterDouglas® Ceilings - Exterior

84C

8416 32

32 20

28.6

45,5

8416

33

12,5

18,5

21 18,5

45

45

21

38

65

12.5

CONSTRUCTION DETAILSThe Luxalon® standard range of edgeprofiles can be used as perimeters.

PANELSThe Luxalon® 84C Closed Ceiling systemconsists of box shaped panels (1) which canbe easily clipped on a 84C carrier (2). The84 mm wide panels feature a 24 mm wideflange that closes-off the 16 mm jointbetween the panels (module 100 mm). The 12.5 mm deep recessed joint gives alinear direction to the ceiling plane whilstbeing closed-off from the plenum. Thepanels are made to measure and can besupplied in any length up to 6000 mm.

SUSPENSIONThe panel carrier (2) is black and is providedwith prongs to accommodate the panels in astandard module of 100 mm. Carriers havea standard length of 5000 mm.

84 16

12,5

Panel Width Module Min. Max. Weight panels & carriers/m2*(mm) (mm) length length Aluminium carrier

(mm) (mm)

84C 84 100 1000 6000 2.1 kg

Unit 84C exterior system

Panels lm 10Carriers lm 0.625Carrier splice pcs 0.12Suspension pcs 3.0

MATERIAL REQUIREMENT PER M2

The required number of componentsdepend on individual project requirements.Figures based on a ceiling installed on 3 ormore carriers and submitted to a windload(pressure) of 1000 N/m2. For corners, roofedges, special designs etc. windpressure/suction shall be determined withdue consideration to the local country’sStandard Codes of Building Practice.

MAXIMUM SPANS

DIMENSIONS & WEIGHTS* Based on panels installed on 3 or morecarriers. The panels are made to measurein any length up to 6000 mm.

Panels > 6000 mm available on request.

3

1

4

2

5

6

8

C

D

E

B

B

B

7

9

A

1 = 84C panel2 = carrier3 = screw washer4 = reinforcement5 = hanger6 = top fixing7 = threaded rod8 = panel splice9 = non-HD

A = Luxalon® Profix cantileverB = carrier spanC = panel spanD = panel cantileverE = Luxalon® Profix-carrier span

See graphs on page 19.

Page 7: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

5HunterDouglas® Ceilings - Exterior

42

75

31,5

15,5

150/225

31,5

15,5

19,5

21 14,5

*

20

45

45

21

42 38

65

CONSTRUCTION DETAILSThe neat closed joints present smoothuninterrupted appearance. By combining the narrow and wide panels (75,150 and225 mm) on one universal carrier, variousdimensional effects are possible, providingthe designer unlimited possibilities.The Luxalon® standard range of edgeprofiles can be used as perimeters.

PANELSThe Luxalon® Closed Ceiling system has achoice of three widths of panels (1). Allthree widths can be combined and easilyclipped on a universal carrier (2). Panelscan be joined by using the panel splice (8).Locking clips (9) for 75C, 150C and 225Care fitted crosswise on to the carrier, on topof the prongue in order to fully secure thepanels and to create a ceiling able towithstand windloads.

SUSPENSIONThe panel carrier (2) is black, made of 0.95 mm thick stove enamelled aluminiumand is provided with prongs to accommo -date the panels in a width of 75, 150 or 225 mm. Carriers have a standard lengthof 5000 mm.

75C, 150C, 225C

75 150 225

15,5

Panel Module Min. Max. Weight panels (mm) length length &

(mm) (mm) carriers/m2*

75C 75 1000 6000 2.63 kg

150C 150 1000 6000 2.29 kg

225C 225 1000 6000 2.28 kg

Unit 75C 150C 225C

Panels lm 13.33 6.67 4.44Carriers lm 0.83 1.0 1.25Carrier splice pcs 0.16 0.2 0.25Locking clips pcs - 6.67 5.55

MATERIAL REQUIREMENT PER M2

The required number of componentsdepend on individual project requirements.Figures based on a ceiling installed on 3 ormore carriers and submitted to a windload(pressure) of 1000 N/m2. For corners, roofedges, special designs etc. windpressure/suction shall be determined withdue consideration to the local country’sStandard Codes of Building Practice.

MAXIMUM SPANS

DIMENSIONS & WEIGHTS* Based on panels installed on 3 or morecarriers. The panels are made to measurein any length up to 6000 mm.

Panels > 6000 mm available on request.

1

9

4

2

5

6

8

C

D

E

A

B

B

B

3

7

10

1 = panel2 = carrier3 = screw washer4 = reinforcement5 = hanger6 = top fixing7 = threaded rod8 = panel splice9 = locking clip

10 = non-HD

A = Luxalon® Profix cantileverB = carrier spanC = panel spanD = panel cantileverE = Luxalon® Profix-carrier span

See graphs on page 20.

Page 8: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Panel Width Min. length Max. length Weight/m2

300A 300 1000 6000 3.7 kg

Unit 300A Carrier system

Panels lm 3.33Carrier lm 1.5Carrier splice pcs 0.3Suspension pcs 2.86Locking clips pcs 5.0

300A Carrier

1/4 x C 3818,5

300A

10290

300A 300A

65

45

80,5

41,5

38,5

62

23,5

*

1/4 x Cmax. 600

Depends onWindloadmax. 600

CONSTRUCTION DETAILSThe Luxalon® standard range of edgeprofiles can be used as perimeters.

* Locking clips

PANELS

The Luxalon® 300A Panels are 290 mmwide and have a recessed joint of 10 mmwidth and a depth of 31 mm. The panelshave straight 14 mm high upstands at thepanel ends to provide rigidity and flatnessto the panels. The small joint, in combina -tion with the flange, creates a (visually)closed ceiling. Locking clips crosswise onevery panel secure the panels to create aceiling able to withstand windloads.

SUSPENSION

The panel carrier is black, made of 0.95 mm thick aluminium and is providedwith prongs to accommodate the panels. Carriers have a standard length of 4950 mm.

MATERIAL REQUIREMENT PER M2

The required number of componentsdepend on individual project requirements.Figures based on a ceiling installed on 4 ormore carriers and submitted to a windload(pressure) of 1500 N/m2. For corners, roofedges, special designs etc. windpressure/suction shall be determined withdue consideration to the local country’sStandard Codes of Building Practice.

DIMENSIONS & WEIGHTSBased on panels installed on 3 or morecarriers. The panels are made to measurein any length up to 6000 mm. Panels from800-1000 mm and > 6000 mm availableon request.

290 10

31.714

6 HunterDouglas® Ceilings - Exterior

MAXIMUM SPANS

3

8

1

4

2

5

6

C

D

E7

A

B

B

B

9

1 = 300A panel2 = carrier3 = screw washer4 = reinforcement5 = hanger6 = top fixing7 = threaded rod8 = locking clip9 = non-HD

A = Luxalon® Profix cantileverB = carrier spanC = panel spanD = panel cantileverE = Luxalon® Profix-

carrier span

See graphs on page 21.

Page 9: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

7HunterDouglas® Ceilings - Exterior

Panel Width Min. length Max. length Weight/m2

300C/L 300 1000 6000 3.7 kg

Unit 300C/L Carrier system

Panels lm 3.33Carrier lm 1.05Carrier splice pcs 0.21Suspension pcs 3.125

3

1

4

2

5

6

C

D

E7

A

B

B

B

8

300C/L Carrier

C Depends onwindloadmax. 600

3818.5

65

45

80.5

41.5

38. 5

62

23.5

max. 6001/4 x C 1/4 x C

CONSTRUCTION DETAILSThe Luxalon® standard range of edgeprofiles can be used as perimeters.

PANELS

The Luxalon® 300C/L Panels (1) are300 mm wide and have resp. a V-joint orL-joint. All panels can simply be fixed onthe carrier (2) by hanging one side of thepanel on the prongs of the carrier and bythen pressing the other side in place withan upward movement. An unclutteredmonolithic ceiling appearance is achievedusing the concealed 300C/300L carriersuspension system. The panels do notrequire any locking clips.

SUSPENSION

The panel carrier is black, made of 0.95 mm thick aluminium and is providedwith prongs to accommodate the panels. Carriers have a standard length of 4950 mm.

MATERIAL REQUIREMENT PER M2

The required number of componentsdepend on individual project requirements.Figures based on a ceiling installed on 4 ormore carriers and submitted to a windload(pressure) of 1500 N/m2. For corners, roofedges, special designs etc. windpressure/suction shall be determined withdue consideration to the local country’sStandard Codes of Building Practice.

DIMENSIONS & WEIGHTSBased on panels installed on 3 or morecarriers. The panels are made to measurein any length up to 6000 mm. Panels from600-1000 mm and > 6000 mm availableon request.

30293029

5

300C 300L

MAXIMUM SPANS

1 = 300C/L panel2 = carrier3 = screw washer4 = reinforcement5 = hanger6 = top fixing7 = threaded rod8 = non-HD

A = Luxalon® Profix cantileverB = carrier spanC = panel spanD = panel cantileverE = Luxalon® Profix-

carrier span

300C 300L

See graphs on page 21.

Page 10: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

8 HunterDouglas® Ceilings - Exterior

MAXIMUM SPANS

150F, 200F

PANELS

The Luxalon® 150F/200F Ceiling systemconsists of 150 mm or 200 mm widealuminium panels (1) which can simply beclipped into the prongs of a 150F or a200F carrier (2). The panels can be joinedby using the panel splice (8).

SUSPENSION

The carrier (2) is black, made of 0.95 mmthick (for 150F) or 1.2 mm thick (for 200F)stove enamelled aluminium and is providedwith prongs to accommodate the panels.Carriers have a standard length of 5000 mm and are connected by using the carrier splice (200F) or by sliding theends of the carriers into each other (150F).

150 200

16

Unit 150F system 200F system

Panels lm 6.67 5Carrier lm 0.61 0.65Carrier splice pcs 0.12 0.13Suspension pcs 3.3 3.45U-bracket (Optional) pcs 2.03 1.63

34.5150/200 38

65

19,5

45 48

max. 600

MATERIAL REQUIREMENT PER M2

The required number of componentsdepend on individual project requirements.Figures based on a ceiling installed on 3 ormore carriers and submitted to a windload(pressure) of 1500 N/m2. For corners, roofedges, special designs etc. windpressure/suction shall be determined withdue consideration to the local country’sStandard Codes of Building Practice.

CONSTRUCTION DETAILSThe neat closed joints present a smoothuninterrupted appearance. Panels can besecured to the carrier by using U-brackets,providing a very rigid system which is ableto withstand extreme wind suction (over2000 N/m2). For installations requiringcombinations of 150F and 200F panels ascrew clamp is available.Curved ceilings can be achieved by using acurved subconstruction with screw clamps. The Luxalon® standard range of edgeprofiles can be used as perimeters.

Panel Width Module Min. Max. Weight panels (mm) (mm) length length &

(mm) (mm) carriers/m2*

150F 150 150 1000 6000 2.8 kg

200F 200 200 1000 6000 3.1 kg

DIMENSIONS & WEIGHTS* Based on panels installed on 3 or more carriers.

Panels from 800-1000 mm and > 6000 mm are available on request.

1

4

2

5

6

8

C

D

E 7

10

A

3

9

B

B

B

1 = 150F/200F panel2 = carrier3 = screw washer4 = reinforcement5 = hanger6 = top fixing7 = threaded rod8 = panel splice9 = U-bracket

10 = non-HD

A = Luxalon® Profix cantileverB = carrier spanC = panel spanD = panel cantileverE = Luxalon® Profix-

carrier span

See graphs on page 22 and 23.

Page 11: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

9HunterDouglas® Ceilings - Exterior

54

29

25

62703018.5 38

*45

65

45

21

54

29

25

703021 18.5

*

CONSTRUCTION DETAILSFlexible carriers are available in order tocreate a curved ceiling.The Luxalon® standard range of edgeprofiles can be used as perimeters.

PANELSThe Luxalon® Exterior 70U Ceiling systemconsists of box shaped, 70 mm wide, 25 mm deep, 0.8 mm thick aluminiumpanels (1) which can be easily clipped on a70U carrier (2). Panels can be joined byusing the panel splice (8). Locking clips (9)are fitted on to the carrier between thepanels in order to fully secure the panels.

SUSPENSIONThe panel carrier (2) is black, made of 0.95 mm thick stove enamelled aluminiumand is provided with prongs to accommo -date the panels in a standard module of100 mm. Carriers have a standard lengthof 5000 mm.

70U

70 30

25

Panel Width Height Module Min. Max. Weight panels 70U (mm) (mm) (mm) length length & carriers/m2*

(mm) (mm) Steel Carrier Alu Carrier

Alu 0.8 70 25 100 1000 6000 3.27 kg 2.9 kg

Unit 70U Ceiling system

Panels lm 10Carrier lm 0.67Carrier splice pcs 0.13Suspension pcs 2.13Locking clips pcs 6.7

MATERIAL REQUIREMENT PER M2

The required number of componentsdepend on individual project requirements.Figures based on a ceiling installed on 3 ormore carriers and submitted to a windload(pressure) of 1000 N/m2. For corners, roofedges, special designs etc. windpressure/suction shall be determined withdue consideration to the local country’sStandard Codes of Building Practice.

MAXIMUM SPANS

DIMENSIONS & WEIGHTS* Based on panels installed on 3 or morecarriers. The panels are made to measurein any length up to 6000 mm.

Panels > 6000 mm available on request.

1

9

4

2

5

67

10

3 8

C

D

E

B

B

B

A

1 = 70U panel2 = carrier3 = screw washer4 = reinforcement5 = hanger6 = top fixing7 = threaded rod8 = panel splice9 = locking clip

10 = non-HD

A = Luxalon® Profix cantileverB = carrier spanC = panel spanD = panel cantileverE = Luxalon® Profix-

carrier span

See graphs on page 24.

Page 12: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

10 HunterDouglas® Ceilings - Exterior

MAXIMUM SPANS

185U

PANELS

The Luxalon® Exterior 185U Ceiling systemconsists of box shaped, 185 mm wide,0.95 mm thick aluminium panels (1) whichcan be easily clicked on the 185U carrier(2). Panels can be joined by using the panelsplice (8). Between the panels there is anopen joint of 15 mm.

SUSPENSION

The carrier (2) is black, made of 0.95 mmthick stove enamelled aluminium and isprovided with prongs to accommodate thepanels in a module of 200 mm. Carriershave a standard length of 5000 mm.

185 15

25

Unit 185U Carrier system

Panels lm 5Carrier lm 0.61Carrier splice pcs 0.12Suspension pcs 4.55

18515

63,545

33,518,5

45

38

65

MATERIAL REQUIREMENT PER M2

The required number of componentsdepend on individual project requirements.Figures based on a ceiling installed on 3 ormore carriers and submitted to a windload(pressure) of 1500 N/m2. For corners, roofedges, special designs etc. windpressure/suction shall be determined withdue consideration to the local country’sStandard Codes of Building Practice.

CONSTRUCTION DETAILSStrong, robust, panels made of 0.95 mmaluminium provide good resistancy againste.g. vandalism. The Luxalon® standard range of edgeprofiles can be used as perimeters.

Panel Width Module Min. Max. Weight panels (mm) (mm) length length &

(mm) (mm) carriers/m2*

185U 185 200 1000 6000 3.4 kg

DIMENSIONS & WEIGHTS* Based on panels installed on 3 or more carriers.

Panels from 250-1000 mm and > 6000 mm are available on request.

1

4

2

5

6

8

C

D

E7

9

A

B

B

B

3

1 = 185U panel2 = carrier3 = screw washer4 = reinforcement5 = hanger6 = top fixing7 = threaded rod8 = panel splice9 = non-HD

A = Luxalon® Profix cantileverB = carrier spanC = panel spanD = panel cantileverE = Luxalon® Profix-

carrier span

See graphs on page 24.

Page 13: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

11HunterDouglas® Ceilings - Exterior

100/150/200

90*

56

146101

CONSTRUCTION DETAILSThe Luxalon® V100 Screen Ceiling systemallows for easy demounting of the panels.Each panel can be easily removed andreplaced by hand. Even without removingthe panels, the system allows for easy andfull access to services and installations inthe plenum.

PANELSThe Luxalon® V100 Screen Ceiling systemis a lightweight, floating ceiling. The panels(1) are 101 mm high (V100) and can easilybe clipped on the carrier (2). Locking clipsmade of clear PVC (8) are used forsecuring the V100 panels. Looking at theceiling in a minimum angle ofapproximately 45 degrees, the ceiling has aclosed appearance.

SUSPENSIONThe panel carriers (2) are white or black,made of 0.95 mm thick aluminium andprovided with prongs to accommodate thepanels in a module of 100 mm, 150 mm or 200 mm. Carriers have a standardlength of 5000 mm.

V100

101

98

Panel Height Min. length Max. length Weight/m2 incl. carrierM 100 M150 M 200

V100 101 1000 6000 2.1 kg 1.5 kg 1.1 kg

Unit M 100 M 150 M 200

Panels lm 10 6.67 5Carriers lm 0.48 0.48 0.48Carrier splice pcs 0.10 0.10 0.10Suspension pcs 0.77 0.77 0.77Locking clips pcs 4.8 3.2 2.4

MATERIAL REQUIREMENT PER M2

Other accessories depend on individualproject requirements.Figures are based on maximum spans andon using 3 or more fixing points.At 500 N/m2 3 or more carriers are used.For corners, roof edges, special designsetc. wind pressure/suction shall bedetermined with due consideration to thelocal country’s Standard Codes of BuildingPractice.

MAXIMUM SPANS

DIMENSIONS & WEIGHTSPanels from 250 -1000 mm and > 6000 mm are available on request.Weights are based on a system installed on 3 or more fixing points.

13

4

2

5

6

C

D

E

A

B

B

B

7

8

9

See graphs on page 25.

1 = V100 panel2 = carrier3 = screw washer4 = reinforcement5 = hanger6 = top fixing7 = threaded rod8 = locking clip9 = non-HD

A = Luxalon® Profix cantileverB = carrier spanC = panel spanD = panel cantileverE = Luxalon® Profix-

carrier span

Page 14: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Hunter Douglas’ QuadroClad® Panels and Multiple Panel Façade systems are both developed as a façade application but are also suitablefor exterior ceilings. Especially when extremely large panel sizes are desired, or if façade and exterior ceiling should form a uniform view inthe architectural design, these systems are excellent solutions. Find in dedicated product brochures all details regarding these products.

Façade systems as Ceiling application

QUADROCLAD® PANELS- Large panel sizes up to 1.500 mm x 10.000 mm

- Extremely flat panels with low weight (6 kg/m2)

- Panels available in curved, cranked and triangular shapes

- Wide choice of finishes (Luxacote®, PVDFand anodized)

- Tightly controlled joint widths- Quick installation with minimum fixings to structure

MULTIPLE PANEL FAÇADE- Large panel sizes up to 600 mm x 6.000 mm

- Wide choice of finishes (Luxacote®, PVDFand anodized)

- The neat closed joints present a smoothuninterrupted appearance

- Quick installation with minimum fixings tostructure

*

*

*

*

2

3

1

CD

B

A

1 = panel2 = fixing rail3 = panel bracket* Non Hunter Douglas

A = fixing rail cantileverB = fixing rail span C = panel spanD = panel cantilever

2

1

3

*

*

*

*

*

C

D

B

A

A = carrier cantileverB = carrier spanC = panel spanD = panel cantilever

12 HunterDouglas® Ceilings - Exterior

1 = panel2 = carrier (for panels

up to 400 mm width)3 = panel clamp

(for all panels)* Non Hunter Douglas

Page 15: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

13HunterDouglas® Ceilings - Exterior

Wall L-profile Alu(45 x 18.5)

Wall L-profile Alu(45 x 32.5)

Wall W-profile Alu(45 x 21 x 21 x 18.5)

EDGE PROFILES

1

2

4

3

5

Mounted system Side view

LUXALON® CLICK-IN PROFILEThe Luxalon® Click-In Profile is a practicaland esthetical edge solution speciallydeveloped for Luxalon® Exterior Ceilings.After fixing the Border profile (1) andinstalling the ceiling panels, the last thingto do is click-in the Edge profile (3). The click-in profile can be used togetherwith any of the L or W shaped edgeprofiles. In case of maintenance the Edgeprofile can be removed before demountingthe ceiling panels.

1 - Border profile2 - Clip3 - Edge profile4 - Hold down clip5 - Adapter panel

Edge solutions

Page 16: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

14 HunterDouglas® Ceilings - Exterior

System System Join Mix Curved Interior Acces Luxalon® Luxacote®

specifications Panel width width different applic. to plenum Profix(mm) (mm) sizes available

84R 84 16* •** • • • •

80B 80 20* • • (Multi • • •panel system)

84B 84 16 • • • • •

84C 84 16 • • • •

75C,150C, 225C 75, 150, 225 - • • • • •

300C 300 - • • • • •

300A 290 10 • • • •

300L 300 - • • • •

150, 200F 150, 200 - • • • •

70U 70 30 • • • • •

185U 185 15 • • •

V100 100 Module 100, • • • On request150 or 200 (V100, V200)

*Join profiles are available and provide a visually closed ceiling ** Panel can also be curved

SpecificationsLUXALON® PROFIXLuxalon® Profix is a suspension systemmade by Hunter Douglas expressly forexterior applications. A cost- and time-saving tool, the system simplifiesinstallation and provides safety andreliability, even when faced with strongwind loads.

Luxalon® Profix consists of:• A strengthening profile; reinforcing ourcarriers, creating a bigger span andtherefore saves on suspension materialand labour (less holes to drill)

• a top fixing; allowing easy mounting ofthe hanger

• a hanger; adaptable in length andresisting high wind forces

MINIMUM AND MAXIMUM PLENUMHEIGHT WITH LUXALON® PROFIXUsing the Luxalon® Profix suspensionsystem provides the benefit of a widevariety in the preferring plenum height.Minimum plenum height is 250 mm,maximum is 1.250 mm (including carrierand reinforcement).

The hangers are available in 10 differentlengths which vary between 200 and 1.100 mm, in steps of 100 mm (200, 300,400 mm etc.). An individual Profix hangerprovides the possibility to vary in length.Each hanger can be adjusted in length + or- 50 mm.

1

2

3

5

6

4

1 = reinforcement2 = hanger3 = screw washer + screw4 = threaded rod5 = top fixing6 = non-HD

SYSTEM SPECIFICATIONS IN GENERALLuxalon® Exterior Ceiling panels are made to measure with a standard maximum length of6.000 mm. The recyclable, lightweight, and strong aluminium panels can be joined byusing the panel splice. The black aluminium panel carrier is provided with prongs toaccommodate the panels, has a standard length of 5.000 mm, and is connected by usingthe carrier splice.

Locking clips are fitted crosswise onto every panel, adjacent to the carriers, in order to fullysecure the panels and create a ceiling able to withstand the strongest wind loads. Thecarrier can be suspended at centers determined by the wind loading graphs, using a rigidlevelled suspension system and the screw washer to isolate dissimilar metals.

Page 17: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

15HunterDouglas® Ceilings - Exterior

0

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

0,00 0,25 0,50 0,75 1,00 1,25 1,50 1,75

Spantable Luxalon® Profix Profile

Characteristic w

ind load

[N/m

1 ]

Profile span

2 Hangers3 Hangers4 or more hangers

0

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

250 350 450 550 650 750 850 950 1050 1150 1250 1350

Buckling Luxalon® Profix hanger

Pressure lo

ad han

ger [N]

Hanger length

- Profile span (x)The profile span, in relation to the wind load (pressure or suction), can be calculated from the graph above. At 1.000 N/m1 the profile spanshould be 1.200 mm (4 or more hangers).

- Buckling load on the hangersBefore establishing the buckling load on the hangers, the load per hanger is to be determined by applying one of the following formulas:

Number of hangers Calculation of ‘pressure load per hanger’

4 per full profile length (1500 mm c.t.c.) 1.1 q x profile span (x) in m

5 per full profile length (1150 mm c.t.c.) 1.143 q x profile span (x) in m

6 per full profile length (900 mm c.t.c.) 1.132 q x profile span (x) in mq = pressureload in N/m1 (uniformly distributed loads on the Luxalon® Profix profile)

The maximum allowed hanger length in relation to the determined pressure load on the hanger can be read from the graph above in thesame way as the profile span. At 1.000 N pressure load the maximum hanger length should be 900 mm.

Note: For corners, roof edges, special designs etc. wind pressure/suction shall be determined with due consideration to the relevant local country’sStandard Codes of Building Practice.

Luxalon® ProFix Calculations

Luxalon® Profix hanger

Page 18: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Maximum Spans84R

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 84R panel with locking clipDesign chart of 84R panel with locking clip

Panels Calculation ofinstalled ’load per linealon: meter carrier’

2 carriers 0.5 q x panel span (C) in m

3 carriers 1.25 q x panel span (C) in m

4 or more 1.15 q x panel span (C)in m

q = windload in N/m2 (uniformly distributedloads)

The carrier span (fixing distance) (B) can be read from the graph besides in thesame way as the panel span.

Note: For corners, roof edges, special designsetc. wind pressure/suction shall be determinedwith due consideration to the relevant localcountry’s Standard Codes of Building Practice.

When join profiles are used the max. admissible panelspan is 800 mm, irrespective to the windload

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 84R panel with U-join profileDesign chart of 84R panel with U-join profile

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 84R panel with V5-join profileDesign chart of 84R panel with V5-join profile

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

5000

6000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80

Maximum distance between carrier fixings [m]

γ LW

[N/m

]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

Design chart of carrier 84RDesign chart of carrier 84R

γLW [N

/m]

Maximum distance between carrier fixings [m]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

- Panel span (c)The panel spans, in relation to the windload (pressure or suction), can be calcu -lated from the graph adjacent.At 1.000 N/m2 the panel span should be 900 mm (84R + open joint on 3 or morecarriers).

- Carrier span (b)Before establishing the fixing distance ofthe carriers, the load per lineal metercarrier is to be determined by applying one of the following formulas:

16 HunterDouglas® Ceilings - Exterior

Page 19: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Maximum SpansMaximum Spans

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 80B panel with clipDesign chart of 80B panel with clip

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 80B panel with join profileDesign chart of 80B panel with join profileCh

aracteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Design chart of carrier 80B

1000

2000

0

3000

4000

5000

6000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80

Maximum distance between carrier fixings [m]

γ LW

[N/m

]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

Design chart of carrier 80B

γLW [N

/m]

Maximum distance between carrier fixings [m]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

80B

Panels Calculation ofinstalled ’load per linealon: meter carrier’

2 carriers 0.5 q x panel span (C) in m

3 carriers 1.25 q x panel span (C) in m

4 or more 1.15 q x panel span (C)in m

q = windload in N/m2 (uniformly distributedloads)

The carrier span (fixing distance) (B) can be read from the graph besides in thesame way as the panel span.

Note: For corners, roof edges, special designsetc. wind pressure/suction shall be determinedwith due consideration to the relevant localcountry’s Standard Codes of Building Practice.

When join profiles are used the max. admissible panelspan is 800 mm, irrespective to the windload

- Panel span (c)The panel spans, in relation to the windload (pressure or suction), can be calcu -lated from the graph adjacent.At 1.000 N/m2 the panel span should be900 mm (on 3 or more carriers).

- Carrier span (b)Before establishing the fixing distance ofthe carriers, the load per lineal metercarrier is to be determined by applying one of the following formulas:

17HunterDouglas® Ceilings - Exterior

Page 20: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Maximum Spans

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 84B panelDesign chart of 84B panel

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Design chart of carrier 84B

1000

2000

0

3000

4000

5000

6000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80

Maximum distance between carrier fixings [m]

γ LW

[N/m

]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

Design chart of carrier 84B

γLW [N

/m]

Maximum distance between carrier fixings [m]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

84B

Panels Calculation ofinstalled ’load per linealon: meter carrier’

2 carriers 0.5 q x panel span (C) in m

3 carriers 1.25 q x panel span (C) in m

4 or more 1.15 q x panel span (C)in m

q = windload in N/m2 (uniformly distributedloads)

The carrier span (fixing distance) (B) can be read from the graph besides in thesame way as the panel span.

Note: For corners, roof edges, special designsetc. wind pressure/suction shall be determinedwith due consideration to the relevant localcountry’s Standard Codes of Building Practice.

- Panel span (c)The panel spans, in relation to the windload (pressure or suction), can be calcu -lated from the graph adjacent.At 1.000 N/m2 the panel span should be 1.100 mm (on 3 or more carriers).

- Carrier span (b)Before establishing the fixing distance ofthe carriers, the load per lineal metercarrier is to be determined by applying one of the following formulas:

18 HunterDouglas® Ceilings - Exterior

Page 21: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Maximum SpansMaximum Spans

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 84C panelDesign chart of 84C panel

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Design chart of carrier 84C

1000

2000

0

3000

4000

5000

6000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80

Maximum distance between carrier fixings [m]

γ LW

[N/m

]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

Design chart of carrier 84CγL

W [N

/m]

Maximum distance between carrier fixings [m]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

84C

Panels Calculation ofinstalled ’load per linealon: meter carrier’

2 carriers 0.5 q x panel span (C) in m

3 carriers 1.25 q x panel span (C) in m

4 or more 1.15 q x panel span (C)in m

q = windload in N/m2 (uniformly distributedloads)

The carrier span (fixing distance) (B) can be read from the graph besides in thesame way as the panel span.

Note: For corners, roof edges, special designsetc. wind pressure/suction shall be determinedwith due consideration to the relevant localcountry’s Standard Codes of Building Practice.

- Panel span (c)The panel spans, in relation to the windload (pressure or suction), can be calcu -lated from the graph adjacent.At 1.000 N/m2 the panel span should be 600 mm (on 3 or more carriers).

- Carrier span (b)Before establishing the fixing distance ofthe carriers, the load per lineal metercarrier is to be determined by applying one of the following formulas:

19HunterDouglas® Ceilings - Exterior

Page 22: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Maximum Spans

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Panel span [m]

Panel spans 75CPanel spans 75C

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Panel span [m]

Panel spans 150CPanel spans 150C

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Panel span [m]

Panel spans 225CPanel spans 225C

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

5000

6000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80

Win

d lo

ad [N

/m1]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

75C-225C Carrier spans closed panels

Carrier span [m]

75C-225C Carrier spans closed panels

Wind load

[N/m

]

Carrier span [m]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

75C, 150C, 225C

Panels Calculation ofinstalled ’load per linealon: meter carrier’

2 carriers 0.5 q x panel span (C) in m

3 carriers 1.25 q x panel span (C) in m

4 or more 1.15 q x panel span (C)in m

q = windload in N/m2 (uniformly distributedloads)

The carrier span (fixing distance) (B) can be read from the graph besides in thesame way as the panel span.

Note: For corners, roof edges, special designsetc. wind pressure/suction shall be determinedwith due consideration to the relevant localcountry’s Standard Codes of Building Practice.

- Panel span (c)The panel spans, in relation to the windload (pressure or suction), can be calcu -lated from the graph adjacent.At 1.000 N/m2 the panel span should be 1.200 mm (75C-panel on 3 or morecarriers).

- Carrier span (b)Before establishing the fixing distance ofthe carriers, the load per lineal metercarrier is to be determined by applying one of the following formulas:

20 HunterDouglas® Ceilings - Exterior

Page 23: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Maximum SpansMaximum Spans

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Panel span [m]

Panel spans 300APanel spans 300A

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Panel span [m]

Panel spans 300CPanel spans 300C/300LCh

aracteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

5000

6000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80

Win

d lo

ad [N

/m1]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

300ACL Carrier spans wide panel

Carrier span [m]

300ACL Carrier spans wide panel

Wind load

[N/m

]

Carrier span [m]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

300A, 300C, 300L

Panels Calculation ofinstalled ’load per linealon: meter carrier’

2 carriers 0.5 q x panel span (C) in m

3 carriers 1.25 q x panel span (C) in m

4 or more 1.15 q x panel span (C)in m

q = windload in N/m2 (uniformly distributedloads)

The carrier span (fixing distance) (B) can be read from the graph besides in thesame way as the panel span.

Note: For corners, roof edges, special designsetc. wind pressure/suction shall be determinedwith due consideration to the relevant localcountry’s Standard Codes of Building Practice.

- Panel span (c)The panel spans, in relation to the windload (pressure or suction), can be calcu -lated from the graph adjacent.At 1.500 N/m2 the panel span should be780 mm (300C panel on 3 or morecarriers).

- Carrier span (b)Before establishing the fixing distance ofthe carriers, the load per lineal metercarrier is to be determined by applying one of the following formulas:

21HunterDouglas® Ceilings - Exterior

Page 24: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Maximum Spans

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 150F panelDesign chart of 150F panel

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 150F panel with clipDesign chart of 150F panel with clip

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

5000

6000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80

Maximum distance between carrier fixings [m]

γ LW

[N/m

]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

Design chart of carrier 150FDesign chart of carrier 150F

γLW [N

/m]

Maximum distance between carrier fixings [m]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

150F

Panels Calculation ofinstalled ’load per linealon: meter carrier’

2 carriers 0.5 q x panel span (C) in m

3 carriers 1.25 q x panel span (C) in m

4 or more 1.15 q x panel span (C)in m

q = windload in N/m2 (uniformly distributedloads)

The carrier span (fixing distance) (B) can be read from the graph besides in thesame way as the panel span.

Note: For corners, roof edges, special designsetc. wind pressure/suction shall be determinedwith due consideration to the relevant localcountry’s Standard Codes of Building Practice.

- Panel span (c)The panel spans, in relation to the windload (pressure or suction), can be calcu -lated from the graph adjacent.At 1.500 N/m2 the panel span should be650 mm (on 3 or more carriers, no clip).

- Carrier span (b)Before establishing the fixing distance ofthe carriers, the load per lineal metercarrier is to be determined by applying one of the following formulas:

22 HunterDouglas® Ceilings - Exterior

Page 25: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Maximum SpansMaximum Spans

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 200F panelDesign chart of 200F panel

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Span [m]

Design chart of 200F panel with clip Design chart of 200F panel with clip Ch

aracteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

5000

6000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80

Maximum distance between carrier fixings [m]

γ LW

[N/m

]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

Design chart of carrier 200FDesign chart of carrier 200F

Wind load

[N/m

]

Carrier span [m]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

200F

Panels Calculation ofinstalled ’load per linealon: meter carrier’

2 carriers 0.5 q x panel span (C) in m

3 carriers 1.25 q x panel span (C) in m

4 or more 1.15 q x panel span (C)in m

q = windload in N/m2 (uniformly distributedloads)

The carrier span (fixing distance) (B) can be read from the graph besides in thesame way as the panel span.

Note: For corners, roof edges, special designsetc. wind pressure/suction shall be determinedwith due consideration to the relevant localcountry’s Standard Codes of Building Practice.

- Panel span (c)The panel spans, in relation to the windload (pressure or suction), can be calcu -lated from the graph adjacent.At 1.500 N/m2 the panel span should be530 mm (on 3 or more carriers, no clip).

- Carrier span (b)Before establishing the fixing distance ofthe carriers, the load per lineal metercarrier is to be determined by applying one of the following formulas:

23HunterDouglas® Ceilings - Exterior

Page 26: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Maximum Spans

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Char

acte

ristic

win

d lo

ad [

N/m

2]

Design chart of 70U panel with locking clip

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

Panel Span [m]

Design chart of 70U panel with locking clip

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 2 stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

6000

5000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

Span [m]

Char

acte

ristic

win

d lo

ad [

N/m

2]

Design chart for 185U panel

Wind pressure or suction 2 stringersWind suction 3 or > stringersWind pressure 3 or > stringers

Design chart for 185U panel

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringersWind pressure 3 or > stringers

1000

2000

0

3000

4000

5000

6000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80

Maximum distance between carrier fixings [m]

γ LW

[N/m

]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

Design chart of carrier 185UDesign chart of carrier 185U

γLW [N

/m]

Maximum distance between carrier fixings [m]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

Design chart of carrier 70U

1000

2000

0

3000

4000

5000

6000

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80

Maximum distance between carrier fixings [m]

γ LW

[N/m

]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

Design chart of carrier 70U

γLW [N

/m]

Maximum distance between carrier fixings [m]

Wind suction 2 fixingsWind suction 3 or > fixingsWind pressure 2 fixingsWind pressure 3 or > fixings

70U, 185U

Panels Calculation ofinstalled ’load per linealon: meter carrier’

2 carriers 0.5 q x panel span (C) in m

3 carriers 1.25 q x panel span (C) in m

4 or more 1.15 q x panel span (C)in m

q = windload in N/m2 (uniformly distributedloads)

The carrier span (fixing distance) (B) can be read from the graph besides in thesame way as the panel span.

Note: For corners, roof edges, special designsetc. wind pressure/suction shall be determinedwith due consideration to the relevant localcountry’s Standard Codes of Building Practice.

- Panel span (c)The panel spans, in relation to the windload (pressure or suction), can be calcu -lated from the graph adjacent.At 1.000 N/m2 the panel span should be1.500 mm (70U panel on 3 or morecarriers).

- Carrier span (b)Before establishing the fixing distance ofthe carriers, the load per lineal metercarrier is to be determined by applying one of the following formulas:

24 HunterDouglas® Ceilings - Exterior

Page 27: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Maximum SpansMaximum Spans

200

400

600

800

1000

1200

1400

1600

1800

400 500 600 700 800 900 1000

Design chart of V100 panel

Characteristic w

ind load

[N/m

2 ]

Panel Span [m]

Wind suction 2 stringersWind suction 3 or > stringers

200

400

600

800

1000

1200

1400

1600

1000 1100 1200 1300 1400 1500 1600 1700 1800

Design chart of carrier V100Wind load

[N/m

]

Carrier span [m]

Wind suction 2 fixingsWind suction 3 or > fixings

V100

Panels Calculation ofinstalled ’load per linealon: meter carrier’

2 carriers 0.5 q x panel span (C) in m

3 carriers 1.25 q x panel span (C) in m

4 or more 1.15 q x panel span (C)in m

q = windload in N/m2 (uniformly distributedloads)

The carrier span (fixing distance) (B) can be read from the graph besides in thesame way as the panel span.

Note: For corners, roof edges, special designsetc. wind pressure/suction shall be determinedwith due consideration to the relevant localcountry’s Standard Codes of Building Practice.

- Panel span (c)The panel spans, in relation to the windload (pressure or suction), can be calcu -lated from the graph adjacent.At 500 N/m2 the panel span should be 900 mm (on 3 or more carriers).

- Carrier span (b)Before establishing the fixing distance ofthe carriers, the load per lineal metercarrier is to be determined by applying one of the following formulas:

25HunterDouglas® Ceilings - Exterior

Page 28: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

26 HunterDouglas® Ceilings - Exterior

Unprecedented Protection

for exterior application

LUXACOTE®

- Colour rangeThe standard Hunter Douglas exterior colour range for Luxalon® Linear Ceiling systemsincludes several different colours and finishes. See colour chart. Any other (RAL or NCS)colour is available on request.

- TolerancesAs a member of the Technical Association of Industrial Metal Ceiling Manufacturers (TAIM),Hunter Douglas complies with tolerance criteria as specified in chapter 4 of the TAIMQuality standards for metal.

CURVED CEILING POSSIBILITIESFlexible carriers: Multipanel, 84B, 84R, 70UCurved panels: 84RCurved subconstruction: 150F, 200F

EXTERIOR CEILINGS

Exterior building applications cope with severe conditions like wind, rain, snow,dirt, vandalism and UV light. Our special aluminium alloy, high-quality surfacetreatments featuring Luxacote® and our windproof systems ensure durability inapplications like canopies, shopping centres and railway/underground stations.

• Box-shape, bevel-edge and round-edge panels• Special alloy of corrosion-resistant aluminium• Luxacote® coating system resistant to UV and scratches and is rain-, dirt- and snow-proof

• Certified for wind loads

- EXTERIOR USEOur proprietary coil-coating processensures ceiling panels get a superbfinish. Independent tests have proventhe excellent performance characteris -tics of Luxacote®. The topcoat containsa solid UV filter that guarantees perfectcolourfastness and gloss stability. The topcoat also offers better resistanceagainst scratches with a structure thatresists and masks any minor damagethat may occur during installation,resulting in a high abrasion resistance.The alloy and pre-treatment also offersoptimal resistance to corrosion.

- ENVIRONMENTWe are dedicated to manufacture asustainable product. Our paint andaluminium melting processes areconsidered to be one of the industrystandards in terms of clean produc -tion processes. All aluminiumproducts are 100% recyclable at the end of their lifecycle.

- FIRE BEHAVIOURLuxalon® Metal SuspendedCeilings are classifiedincombustible and will thereforenot contribute to possible fires.When ceilings however need toprotect the structural integrity ofthe building, Luxalon® Ceilingsoffer a range of practical andtested solutions with regards tofire resistance and fire stability.Further information is availableon request.

Material specifications

Page 29: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Project : DyrupLocation : Copenhagen, DenmarkProduct : Luxalon® Ceiling: type Linear

Multipanel ExteriorQuantity : 6.000 m2

Architect : Bjarne Frost Arkitekter, ThomasSeemann

Impressions

Project : PA Consult C&HLocation : Copenhagen, DenmarkProduct : Luxalon® Ceiling, type Wide Panel

ExteriorQuantity : 1.200 m2

Architect : Perlt&Black a/s C&H

27HunterDouglas® Ceilings - Exterior

Page 30: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

HUNTER DOUGLAS ARCHITECTURAL PRODUCTS

In the last 50 years, we’ve been fortunate enough to help turn

countless innovative sketches into innovative buildings.

Architects, designers, investors and contractors from around the

world have taken advantage of Hunter Douglas’ unmatched product

development, service and support. Chances are, you’ve seen more of

Hunter Douglas than you think.

With major operation centres in Europe, North America, Latin America,

Asia and Australia, we’ve contributed to thousands of high-profile

projects, from retail and commercial facilities to major transit centres

and government buildings.

Not only are the world’s architects and designers our partners, they’re

our inspiration. They continue to raise the bar for excellence. We create

products that help bring their visions to life: Window Coverings,

Ceilings, Sun Control Systems and Façades.

Our paint and aluminium melting

processes are considered to be

one of the industry standards in

terms of clean pro duc tion

processes. All aluminium

products are 100% recyclable

at the end of their lifecycle.

Hunter Douglas products and

solutions are designed to

improve indoor environmental

quality and conserve energy,

supporting built environments

that are comfortable, healthy,

productive, and sustainable.

Promoting sustainable

forest management

www.pefc.org

28 HunterDouglas® Ceilings - Exterior

Page 31: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

HUNTER DOUGLAS is a publicly tradedcompany with activities in more than 100 countries with over 150 companies.

The origin of our company goes back to 1919,in Düsseldorf, Germany. Throughout our history,we have introduced innovations that haveshaped the industry, from the invention of thecontinuous aluminium caster, to the creation ofthe first aluminium Venetian Blinds, to thedevelopment of the latest high-quality buildingproducts.

Today we employ more than 16,500 people inour companies with major operation centres inEurope, North America, Latin America, Asia and Australia.

Contact our Sales office

www.hunterdouglascontract.com

Learn More

ARCHITECTURAL SERVICES

We support our business partners with a wide range of

technical consulting and support services for architects,

developers and installers. We assist architects and

developers with recommendations regarding materials,

shapes and dimensions and colours and finishes. We

also help creating design proposals, visualisations and

mounting drawings. Our services to installers range

from providing detailed installation drawings and

instructions to training installers and advising on the

building site.

Innovative ProductsMake Innovative Projects

® Registered trademark - a HunterDouglas® product Pats. & Pats. Pend. - Technical data subjectto change without notice. © Copyright Hunter Douglas 2014. No rights can be derived from copy,text pertaining to illustrations or samples. Subject to changes in materials, parts, compositions,designs, versions, colours etc., even without notice. MX800C00

Page 32: Exteriorassets2.hunterdouglascontract.com/documents/ceiling/Brochures...Exterior Luxalon ® Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended

Belgium

Bulgaria

Croatia / Slovenia

Czechia

Denmark

France

Germany

Greece

Hungary

Italy

The Netherlands

Norway

Poland

Portugal

Romania

Russia

Serbia

Slovakia

Spain

Sweden

Switzerland

Turkey

United Kingdom

Africa

Middle East

Asia

Australia

Latin America

North America

Linear

Wide Panel

Screen

CellStretch metal

TilesXL panel

Exterior

Curved

HUNTER DOUGLAS MIDDLE EASTP.O. Box 17283

Jebel Ali - Dubai - United Arab Emirates

Tel. +971 (0)4 - 813 18 00

Fax +971 (0)4 - 886 33 01

e-mail [email protected]

www.hunterdouglascontract.com