lynx series lynx plus lynxr-2 lynxr-en lynxr-i lynxr-isia
TRANSCRIPT
Lynx SeriesLynx PlusLynxR-2LynxR-ENLynxR-iLynxR-iSIA
Honeywell Proprietary
Honeywell.com
2
Lynx Series Web
Agenda
•Panel Features
•Connecting an AlarmNet Communicator
•Programming Locations
•*56 Enhanced Zone Programming
•*80 Device Programming
•*81 Zone List Programming
Honeywell Proprietary
Honeywell.com
3
Lynx Series Web
Features
•AlarmNet Communicator Compatible *•IP/GSM Downloading Compatible *•Wireless Siren Compatible – 5800WAVE•Wireless Keypad Compatible – 5828V Fixed English•Built in Speakerphone•Built in Remote Phone Control•Built-in Two-way voice system - AAV•Numeric Pager Reporting •Follow-Me Alarm Reporting (voice message)
* Options of the Lynx Plus, LynxR-2 and LynxR-iCentral Station reporting required for Pager and Follow-Me Alarm
reports except for Open and Close reports
Honeywell Proprietary
Honeywell.com
4
Lynx Series Web
Plus Features
•Supports two-way voice over GSM radio
–with the GSMVLP radio module
•Full 16-button keypad with easy-to-read LCD display and status LEDs
–2” x 16” Custom Alpha backlit display
•Hinged cover for simpler installations
Honeywell Proprietary
Honeywell.com
5
Lynx Series Web
•Rechargeable batteries–6 x 1.2V Nickel Metal-Hydride pack
•provides 24 hours of standby
•Enhanced Enroll Mode–Can enroll Confirm serial number–View serial number–Change loop number w/o deleting
•RF jam detection
Features
Honeywell Proprietary
Honeywell.com
6
Lynx Series Web
Features•1 Hardwire zone – Not present on LynxR-2 or LynxR-i
•24 Wireless zones
•16 Button zones–5804, 5804BD, BDV, & 5802MN
•8 user codes–1 installer
–1 master
–1 duress
–5 standard
•84 Event log – Viewable from Compass Only
•On-board UL 85db siren
Lynx Series
AlarmNet Connections
Honeywell Proprietary
Honeywell.com
8
Lynx Series Web
AlarmNet CommunicatorGSMVLP
Status LEDs
Signal Strength LED
Must be solid.
Registration and Test Switch
Honeywell Proprietary
Honeywell.com
9
Lynx Series Web
Lynx Plus AlarmNet Communicator MountingInstalling the GSMVLP Module
Honeywell Proprietary
Honeywell.com
10
Lynx Series Web
AlarmNet Communicator ConnectionWiring Connections and Routing
Honeywell Proprietary
Honeywell.com
11
Lynx Series Web
AlarmNet CommunicatorGSML
Status LEDs
Signal Strength LED
Must be solid.
Registration and Test Switch
Honeywell Proprietary
Honeywell.com
12
Lynx Series Web
AlarmNet CommunicatorGSML
Honeywell Proprietary
Honeywell.com
13
Lynx Series Web
AlarmNet Communicator ConnectionsLynxR-2/R-i & 7847i-L Configuration B
Honeywell Proprietary
Honeywell.com
14
Lynx Series Web
AlarmNet Communicator ConnectionsLynxR-2/R-i & 7845GSM / 7845i-GSM
Do Not Connect the 7845GSM internal
battery!
NOTE: DC Power is supplied from Lynx panel.
Honeywell Proprietary
Honeywell.com
15
Lynx Series Web
AlarmNet Communicator Connections
LynxR-2/R-i & 7847i
Honeywell Proprietary
Honeywell.com
16
Lynx Series Web
AlarmNet Communicator Connections
LynxR-EN & AlarmNet Device
Program your AlarmNet Device in V- (neg) Zone Mode.
2K Ohm Pull up resistor.
Honeywell Proprietary
Honeywell.com
17
Lynx Series Web
AlarmNet Communicator Connections - LynxDM-GSM
Honeywell Proprietary
Honeywell.com
18
Lynx Series Web
AlarmNet Communicator ConnectionsLynxDM-GSM
Lynx Series
Programming
Honeywell Proprietary
Honeywell.com
20
Lynx Series Web
Programming Locations
* 20 Installer Code [4112]
To change the Inst. Code you would enter *20 then the new code:
For example: Change Installer code to 4321
* 2 0 4 3 2 1 (after entry of last digit the keypad will beep 3 times to confirm the entry and automatically proceed to location *21)
Example 1
Honeywell Proprietary
Honeywell.com
21
Lynx Series Web
Programming Locations
*20 Installer Code [4112]
To view what is in location *20 you would enter:
# 2 0 the panel will then display the location contents one digit at a time (in hexadecimal format)
For example: # 2 0 then the panel would display:
04 (beep) 03 (beep) 02 (beep) 01 (beep, beep, beep)The installer code is 4321.
A triple beep is heard after the last digit of the field is displayed.
Example 1
Honeywell Proprietary
Honeywell.com
22
Lynx Series Web
Programming Locations
*21 Quick Arm Enable [1] 0 = no; 1=yes
[0] 0 = always on 1 = off after 10secs
[00] 00 = disable01-31 = house ID
*24 RF House ID Code
*22 Keypad Backlight Time Out
Honeywell Proprietary
Honeywell.com
23
Lynx Series Web
Programming Locations
*25 Powerline Carrier device House Code
*31 Single Alarm Sounding/Zone
[0]
[0] 0 = no; 1 = yesProgram zones to chime on zone list 3
[0] 0 = no limit
1 = yes, once per arming
*26 Chime by Zone
*33 Alarm Bell Timeout [1] 0 = none; 1 = 4min
2 = 8min; 3 = 12min; 4 = 16min
*31 Single Alarm Sounding/Zone SIA [0]
0 = Same as Shutdown in field *921 = yes, once per arming period
Honeywell Proprietary
Honeywell.com
24
Lynx Series Web
Programming Locations
This is March and November.
[2,1] *30 Daylight Saving Time Start/End Weekend
Daylight Saving Time
*29 Daylight Saving Time Start/End Month
[3,11]
This is the 2nd Sunday in March and the 1st Sunday in November.
Honeywell Proprietary
Honeywell.com
25
Lynx Series Web
SIA Entry Exit Times
[6,0] 00-99 = exit delay time (in sec)97 = 120 sec delay
[3,0]30-96 = entry delay time (in sec.)97 = 120 sec; 98 = 180 sec; 99 = 240 sec
*35 Entry Delay 1 (zone type 01)
*34 Exit Delay
SIA: Must be set to a minimum 45 sec.
SIA: The entry delay must be set to a minimum of 30 seconds. The sum of entry delay 1 field *35 and the burglary abort window entered in *50 should not exceed 1 minute.
Honeywell Proprietary
Honeywell.com
26
Lynx Series Web
SIA Entry Exit Times
[3,0]*36 Entry Delay 2 (zone type 02)
SIA: The entry delay must be set to a minimum of 30 seconds. The sum of entry delay 2 field *36 and the burglary abort window entered in *50 should not exceed 1 minute.
[0] 0 = no; 1 = yes*50 15 sec Dialer Delay (Burg)
30-96 = entry delay time (in sec.)97 = 120 sec; 98 = 180 sec; 99 = 240 sec
[2] 1 = 15 sec; 2 = 30 sec; 3 = 45 sec
*50 Burglary Abort Window SIA
Honeywell Proprietary
Honeywell.com
27
Lynx Series Web
Phone Options
*38 Confirmation of Arming Ding
*40 PABX Access CodeSIA PABX/Call Waiting Disable
*41 Primary Phone No. ...Up to 20 digits
[0]
0 = no; 1 = yes (when armed by self-contained keypad or RF)2 = yes (when armed by RF only)
Up to 6 digits
Honeywell Proprietary
Honeywell.com
28
Lynx Series Web
Phone Options
*42 Secondary Phone No.
…
The Account Number will be 10 digits only if 10 Digit Contact ID Format is selected in *48 Report Format.
Up to 24 digits
Numeric Pager or Follow-Me Alarm
*43 Primary Account Number
*44 Second Account Number
4 or 10 Digits [ FFFF ]
4 or 10 Digits [ FFFF ]
Honeywell Proprietary
Honeywell.com
29
Lynx Series Web
Phone Options
*47 Phone System Select [5]
Central Station Dialing Mode
Pulse Tone Pulse Tone
No WATS 0 = No Speaker
Phone
1 = No Speaker
Phone
4 = With Speaker
Phone
5 = With Speaker
Phone
WATS 2 = No Speaker
Phone
3 = No Speaker
Phone
6 = With Speaker
Phone
7 = With Speaker
Phone
*46 Follow-Me Reminder Phone Number …
Up to 24 digits
Honeywell Proprietary
Honeywell.com
30
Lynx Series Web
Phone System Select
*47 Phone System Select [5]
SIA Only SIA Only
Honeywell Proprietary
Honeywell.com
31
Lynx Series Web
Format
*48 Report Format for PRIM/SEC. [ 7,7 ]
Primary Secondary
0 = 3+1, 4+1 Ademco L/S Standard 6 or undefined = 4+2 Ademco Express1 = 3+1 4+1 Radionics Standard 7 = Ademco Contact ID reporting2 = 4+2 Ademco L/S Standard 8 = 3+1, 4+1 Ademco L/S Expanded3 = 4+2 Radionics Standard 9 = 3+1, 4+1 Radionics Expanded5 = Ademco 10 Digit Contact ID Format
NOTE: Option 5 or 7 (Ademco Contact ID) must be selected for AAV.
ADEMCO Contact ID Example: 1234 E 131 00 C005This is a new Perimeter Alarm on Zone 5,Account #, the Event (E = new, R = restore )Event Code, Zone #
Honeywell Proprietary
Honeywell.com
32
Lynx Series Web
Reporting OptionsDialer Programming
*49 Split/Dual Reporting [0] 0 = Disable (Backup report only)
TO PRIMARY PHONE No. TO SECONDARY PHONE No. 1 = Alarms, Restore, Cancel Others 2 = All except Open/Close , Test Open/Close, Test 3 = Alarms, Restore, Cancel All 4 = All except Open/Close, Test All 5 = All All TO PRIMARY PHONE No. TO PAGING No. (Secondary) 6 = All except Open/Close Alarms, Open/Close‡, Troubles 7 = All reports Alarms, Trouble 8 = All reports Alarms, Open/Close‡, Troubles 9 = All except Open/Close Open/Close‡ TO PRIMARY PHONE No. TO Follow-Me Alarm No. (Secondary)10 = All except Open/Close Alarms, Open/Close‡, Troubles11 = All reports Alarms, Trouble12 = All reports Alarms, Open/Close‡, Troubles13 = All except Open/Close Open/Close‡
‡ Will report users 0, 5-8 or wireless arm/disarm buttonZones 26-33; all other zones and users do not report
Honeywell Proprietary
Honeywell.com
33
Lynx Series Web
Periodic Test
[0] 0 = none; 1 = 24 hrs;
2 = weekly; 3 = 30 days
[2] 0 = 24 hr; 1 = 6 hrs;
2 = 12 hrs; 3 = 18 hrs*52 First Test Report Offset
*51 Periodic Test Report
[1,0]*64 Test Report Code
[0,0]*76 Test Restore Report Code SIASent when test mode is exited.
Honeywell Proprietary
Honeywell.com
34
Lynx Series Web
*59 Exit Error Report Code [1]
[1,0]*60 Trouble Report Code
*66 Arm Away/Stay Rpt Code [0,0]AWAY STAY
[0]*65 Open Report Code
Programming Locations
Honeywell Proprietary
Honeywell.com
35
Lynx Series Web
Programming Locations
0 = Redundant reporting 1 = 15 seconds 2 = 30 seconds 3 = 45 seconds 4 = 60 seconds 5 = 75 seconds 6 = 90 seconds 7 = 105 seconds
[0, 0]*77 Dynamic Signaling Delay/ Dynamic Signaling Priority
8 = 120 seconds 9 = 135 seconds #10 = 150 seconds #11 = 165 seconds #12 = 180 seconds #13 = 195 seconds #14 = 210 seconds #15 = 225 seconds
1st Entry (delay before switching Central Station reporting path)
2nd Entry
0 = Primary Dialer First1 = LRR/IP First2 = LRR/IP Reporting Only
*55 Enable LRR/IP Communications Device
[0] 0 = Disable;1 = Enable
Honeywell Proprietary
Honeywell.com
36
Lynx Series Web
*87 Aux Function 1-button paging or Macro– Send 999-9999 to a pager or can be a Macro
*88 Pager Characters– Enter up to 16 digits as needed for customizing pager messages
or pager requirements (PIN’s etc.)
Programming Locations
[3]
4 = Bypass/Bypass Restore; 8 = Open/CloseTo select all, enter #15
*90 Event Logging
0 = None; 1 = Alarm/Alarm Restore2 = Trouble/Trouble Restore;
Honeywell Proprietary
Honeywell.com
37
Lynx Series Web
Programming Locations
[2]
0 = None; 1 = AVM & remote phone control2 = remote phone control only4 = AVM only
[0]
0 = 10 Alarm/Alarm Restore Reports; 1 = Unlimited
*92 Number Of Reports in Armed Period
*91 Alarm Audio Verification/Remote Phone Control
[1]
1 = shutdown after one alarm2 = shutdown after two alarms
*92 Swinger Shutdown SIA
Honeywell Proprietary
Honeywell.com
38
Lynx Series Web
…Up to 20 Digits
[0]
0 = Disable Station Initiated Download; 1-14 = Number of rings; 15 = Answering Machine Defeat
*95 Ring Detect Count for Downloading
*94 Download Phone No.
Programming Locations
Honeywell Proprietary
Honeywell.com
39
Lynx Series Web
*96 Initializes Download ID, Subscriber Account No. For Initial Download; No entry required
*97 Select 1 of 4 Default Option Setups. Enter 1-4 to select from default tables 1-4. Enter 0 to abort.
*98 Exits Programming mode and prevents re-entry by Installer Code +8+0+0
*99 Exits Programming mode and allows re-entry by Installer Code +8+0+0
Programming Locations
Lynx Series
*56 Enhanced Zone Programming
Honeywell Proprietary
Honeywell.com
41
Lynx Series Web
*56 Enhanced Zone Programming
A 02 Zone NumberEnter the 2-digit zone number to be programmed[*] = Continue00 = exit zone programming mode
Zone TypeEnter the 2-digit zone type. [*] = Continue
b 01
00 = Not Used 08 = 24 Hr. Aux
01 = Entry/Exit #1 09 = Fire without verify
02 = Entry/Exit #2 10 = Interior w/Delay
03 = Perimeter 20 = Arm-Stay
04 = Interior Follower 21 = Arm-Away
05 = Trouble Day/Alarm Night 22 = Disarm
06 = 24Hr. Silent 23 = No Alarm Response
07 = 24Hr. Audible 24 = Silent Burglary
A 02ZONE NUMBER
b 01 ENTR/EXIT#1ZONE TYPE
Honeywell Proprietary
Honeywell.com
42
Lynx Series Web
*56 Enhanced Zone Programming
Input Type
Enter the input type3 = Supervised RF (RF) 4 = Unsupervised RF (UR)5 = Button type (BR) [*] = Continue
Loop Number It takes 4 transmissions to learn in the Serial and Loop Numbers.1st Fault and Restore – a single beep will sound.2nd Fault and Restore – a double beep will sound.
-If a voice descriptor is already programmed for the zone, it will also be announced.
Report Code
Enter the report code
C 10
E2LOOP#/AUTO LEARN
d 3
E 1
C10REPORT CODE
d 3 RF SUPERVSDINPUT TYPE
Honeywell Proprietary
Honeywell.com
43
Lynx Series Web
*56 Enhanced Zone Programming
Enroll Mode
0 = Skip to the VOICE DESCRIPTOR prompt (1C)1 = Enroll now and proceed to SERIAL NUMBER prompt (1b) (If “ L” is not displayed)2 = Copy the last serial number from the local memory buffer (If “L” is not displayed)3 = View existing serial number. (Only if “L” is displayed)9 = Delete existing serial number. (Only if “L” is displayed)[*] = Advance to the VOICE DESCRIPTOR prompt (1C)
An “L” will appear after the loop number if the loop number was learned in.
1A L
E2L LEARNEDLOOP#/AUTO LEARN
E 2L
1AL A000-1234ENROLL MODE
Honeywell Proprietary
Honeywell.com
44
Lynx Series Web
*56 Enhanced Zone ProgrammingManual Serial Number Entry
Press [1] at the 1A prompt to manually enter the transmitters serial number
Manually enter the transmitter’s 7-digit serialnumber. When all 7 digits are entered, press the [*] key.
After entry is completed, you may trip the transmitter to confirm the serial number entry is correct, or press [*] to skip.
1A
1b
1A L
1AENROLL MODE
1bSERIAL NUMBER
1AL A000-1234ENROLL MODE
Honeywell Proprietary
Honeywell.com
45
Lynx Series Web
*56 Enhanced Zone Programming
Voice Descriptor-(Can also be entered separately in *84)
0 = skip to next zone1 = Enter descriptor mode
FRONT
Descriptor 1
Enter [#] + 2 digit vocabulary index number6 = accept word and advance to descriptor 28 = accept word and advance to next zone
1C
1CZONE DESCRIPTOR
1d 47
1d47Front
Honeywell Proprietary
Honeywell.com
46
Lynx Series Web
*56 Enhanced Zone Programming
Descriptor 2
SLIDING
Enter [#] + 2 digit vocabulary index number6 = accept word and advance to descriptor 38 = accept word and advance to next zone
Descriptor 3
Enter [#] + 2 digit vocabulary index number8 = accept word and advance to next zone(A prompt)DOOR
00 = exit zone programming mode
1E 69
1F 12
A 03
A03ZONE NUMBER
1E69Sliding
1F04Door
Lynx Series
*80 Device Programming
Honeywell Proprietary
Honeywell.com
48
Lynx Series Web
*80 Device ProgrammingDevice Programming0 = Exit mode1 = Enter mode
Device NumberEnter the 2-digit device number 01-08 = X-1009-16 = Multi-Mode Total Connect[*] = Continue00 = Exit Device Programming modeDevice ActionEnter the 1-digit action 0 = No response 1 = Close for 2 seconds 2 = Close and stay closed 3 = Pulse on and off[*] = Continue
80
80DEVICE PROG MENU
A01
A01DEVICE NUMBER
b 2
b02DEVICE ACTION
Honeywell Proprietary
Honeywell.com
49
Lynx Series Web
Start Event Type
Enter the 1 – digit start event type0 = Not used 3 = Trouble1 = Alarm [*] = Continue2 = Fault
Start Zone ListEnter the 1– digit zone list number, 1-3, or 0if not used;[*] = Continue
*80 Device Programming
d 1
d01START ZONE LIST
C 2
C02START EVENT TYPE
Honeywell Proprietary
Honeywell.com
50
Lynx Series Web
Start Zone Type
Enter the 2-digit start zone type[*] = Continue
Stop Zone List
Enter the 1-digit zone list number, 1-3, or 0if not used[*] = Continue
Stop Zone Type
Enter the 2-digit stop zone type[*] = Return to Device Number prompt (A)
*80 Device Programming
E 00
E00START ZONE TYPE
F 0
F00STOP ZONE LIST
1A22
1A22STOP ZONE TYPE
A02 A02DEVICE NUMBER
Lynx Series
*81 Zone Lists
Honeywell Proprietary
Honeywell.com
52
Lynx Series Web
*81 Zone List Programming
Zone List Programming
0 = Exit mode 1 = Enter mode
Zone List Number
Enter the 2-digit zone list number (01-03)[*] = Continue; 00 = Exit mode
Zone Entry To List
Enter the 2-digit zone number[*] = Accept zone number and enter the next zone number00 = Accept zone number and continue to next prompt
81
81ZONE LISTS MENU
A01
A01ZONE LIST NUMBER
b28
b28ZN ENTRY TO LIST
Honeywell Proprietary
Honeywell.com
53
Lynx Series Web
*81 Zone List Programming
Delete Entire Zone List?
0 = Don’t delete; continue to next prompt1 = Delete the current zone list
Delete Specific Zones from List?
Delete Zones
Enter the 2-digit zone number to be deleted[*] = Delete zone00 = Return to next zone list number
0 = Don’t delete; continue to next zone list number1 = Continue to delete zones prompt
C
CDEL WHOLE ZN LST
d
dDEL 1 ZN FRM LST
E
E00DELETE ZONES
Honeywell Proprietary
Honeywell.com
54
Lynx Series Web
Review Quiz
•How do we view what is in a standard programming location?
•How do we enter data in standard programming location?•What programming mode do we use to program in wireless transmitters?
•Does the LynxR-EN have an event log?
•Will the system report in Contact ID with an AlarmNet Communicator?
http://www.security.honeywell.com/hsc/
and click on MyWebTech
User name: honeywell
Password: support99
Honeywell Security support e-mail: [email protected]