mtonereferencemedical.com/wp-content/uploads/2020/08/quanta... · 2020. 8. 27. · laser...

6
e Next Generation Multi-Source Platform IPL - Laser Er:YAG - Laser DIODE MTOne Taking care of people, our masterpieces Aesthetics This brochure is not intended for the U.S. market. Certain Intended Uses/Configurations/Models/Accessories are not cleared for U.S.

Upload: others

Post on 12-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MTOnereferencemedical.com/wp-content/uploads/2020/08/Quanta... · 2020. 8. 27. · LASER TECHNOLOGIES ERGONOMIC HANDPIECES Accessories have been designed specifically for easy and

The Next Generation Multi-Source PlatformIPL - Laser Er:YAG - Laser DIODE

MTOne

Taking care of people, our masterpieces

AestheticsThis brochure is not intended for the U.S. market.Certain Intended Uses/Configurations/Models/Accessories are not cleared for U.S.

Page 2: MTOnereferencemedical.com/wp-content/uploads/2020/08/Quanta... · 2020. 8. 27. · LASER TECHNOLOGIES ERGONOMIC HANDPIECES Accessories have been designed specifically for easy and

Aesthetics

MULTI-TECHNOLOGY PLATFORMFOR AESTHETIC TREATMENTS

DISCOVER YOUR ORIGINAL BEAUTY

LASERS HANDPIECES

Diode 808 nm

• Permanent Hair Reduction*

Er:YAG 2940 nm

• Photo-Rejuvenation

Pain Free High-Speed Hair Reduction option

Only System to Offer IPL, High Speed Diode andFractional/Ablative Skin Resurfacing in One Device

Integrated Contact Cooling with optimized Pulse Technology for IPL Treatments

Advanced Cooling to -12° C available for more comfortable treatments

Portable, but includes convenient storage trolley

IPL HANDPIECES

HR 630 • Permanent Hair Reduction

HR 580 • Permanent Hair Reduction

SR 580 • Photo-Rejuvenation

LP-LV 530 • Pigmented Lesions • Vascular Lesions

AC 420 • Acne Vulgaris

HR IN MOVING 630 • Permanent Hair Reduction

Page 3: MTOnereferencemedical.com/wp-content/uploads/2020/08/Quanta... · 2020. 8. 27. · LASER TECHNOLOGIES ERGONOMIC HANDPIECES Accessories have been designed specifically for easy and

IPL WITH ADAPTIVE PULSE CONTROL (APC)HYPER- SEQUENTIAL ENERGY PULSES

EXTREMELY EFFECTIVE AND SAFE

The State-of-Art APC technology with different pulse and wave-length configurations, combined with the powerful contact skin cooling and sapphire waveguide, is able to perform comfortable and effective treatments in all skin conditions.

The handpieces have different optical filters for the delivery of the best range of wavelengths for each treatment, the skin cooling is able to keep a very low temperature even during the “In Moving”

APC technology is an advanced IPL pulse control system for the automatic selection of the best treatment configuration. This feature considers each of the conditions to be treated and adjusts the right pulse sequence along with the energy needed for a safe and effec-tive treatment.With APC, operators can acquire more rapidly and safely the experience to perform excellent and fully satisfactory treatments to their patients.

procedures and allows treatments without the use of gel, so that, the operator has always the ideal treatment conditions.

MTOne with IPL handpieces has three different configurations for the energy emission to perfectly fit the needs of all difficult treatment conditions such as thin hairs or dark skins. All pulse configurations has a special smooth shape for the delivery of “flat top” waves with no spikes for safer treatments also on dark skins.

HR IN MOVING 630THE SOLUTION FOR PAINLESS HAIR REDUCTION TREATMENTSThe HR IN MOVING handpiece is for the inhibition of hair regrowth using really fast sequences of pulses.This procedure is especially suitable for treatments on dark and tanned skins.

damage threshold

hair temperatureskin temperature

pulse pulse pulse pulse

tem

pera

ture

LONG ADAPTIVE PULSEFor average skin types, brown hairof medium thickness andvascular lesions.

HIGH ADAPTIVE PULSEFor light skin, light thin hairs,small benign vascular lesions andlight benign pigmented lesions.

REGULAR PULSEIdeal for dark skin, dark and thick hair,skin damaged by sun exposure or age,and for pigmented and dark vascular lesions.

Page 4: MTOnereferencemedical.com/wp-content/uploads/2020/08/Quanta... · 2020. 8. 27. · LASER TECHNOLOGIES ERGONOMIC HANDPIECES Accessories have been designed specifically for easy and

Aesthetics

THE MTOneLASER TECHNOLOGIES

ERGONOMIC HANDPIECESAccessories have been designed specifically for easy and accurate face and body application.

VERSATILE COMBINATIONSMTOne platform combines lasers and APC technologies for the most suitable treatment.

DIODE 808It is the ideal laser for permanent hair reduction, thanks to the extreme tolerability and efficacy.Available in different emission modes: continuous wave, pulsed, burst (repeated pulses).

• Fast treatment• Cooled tip down to -12 °C• High efficiency up to 10 Hz

Er:YAG 2940It is designed to perform ablation procedures both fractional and homogeneous. The Er:YAG laser @ 2940 nm is able, through the variation of pulse parameters, to remove layers of skin with minimal thermal damage or produce higher coagulation suitable for the stimulation of collagen production.

Page 5: MTOnereferencemedical.com/wp-content/uploads/2020/08/Quanta... · 2020. 8. 27. · LASER TECHNOLOGIES ERGONOMIC HANDPIECES Accessories have been designed specifically for easy and

RESULTSBEFORE / AFTER

Courtesy Anna Maria Aste MD

Courtesy Matteo Tretti Clementoni MD

Courtesy Matteo Tretti Clementoni MD

VASCULAR LESIONS

BENIGN PIGMENTED LESIONS

VASCULAR LESIONS AND BENIGN PIGMENTED LESIONS

Courtesy Paolo Sbano MD

Courtesy Matteo Tretti Clementoni MD

Courtesy Anna Maria Aste MD

BENIGN PIGMENTED LESIONS

VASCULAR LESIONS

PERMANENT HAIR REDUCTION

Page 6: MTOnereferencemedical.com/wp-content/uploads/2020/08/Quanta... · 2020. 8. 27. · LASER TECHNOLOGIES ERGONOMIC HANDPIECES Accessories have been designed specifically for easy and

QT

S-M

TON

E-re

v001

-RO

TW

Application Handpiece Fluence J/cm2 Pulse width ms Spot Size cm2

Hair removal HR630 5-25 15-100 6,4 In Moving hair removal in moving 635 5-9

6

6,4Photo-rejuvenation SR580 5-25 10-25 6,4Vascular and pigmented lesions LP530 5-25 10-25 6,4Acne AC420 5-15 15-100 6,4

Application Handpiece Fluence Pulse width ms Spot Size

Photo-rejuvenation

Er:YAG 2940

up to 95 J/cm2 on Ø2mm spot

from 0,4 to 1,5 Ø mm 2, 4, 9 ablative

Ø mm 9 fractionalHair removal Diode 808 up to 90 J/cm2 from 1 to 200 1.68 cm2

Electrical requirements 110-240V; 50/60 Hz; 1250 VADimensions and weight 600 (W) x 580 (D) x 550 (H) mm3; 50 Kg (without wheeled base) 600 (W) x 580 (D) x 1180 (H) mm3; 60 Kg (with wheeled base)Interface 10,1” Colour Touch screen

CAUTION - Laser radiation

APC TECHNOLOGY

LASER TECHNOLOGY

TECHNICAL SPECIFICATIONS

Quanta System products are manufactured according to the International standards and have been cleared by the most important International notified bodies.The Company is EN ISO 9001:2008 and EN ISO 13485:2012 certified. Quanta System S.p.A. was founded in 1985 and belongs to the EI. En. Group (a public com-pany listed in the Star segment of the Italian Stock Exchange) since January 2004. The company, divided into three business units (medical, scientific and industrial) is specialized in manufacturing of laser and opto-electronic devices.

Note: National local authorities may put restrictions to the parameters indicated in the above table, or may limit or remove certain intended uses. Specifications are subject to change without notice.

Quanta System [email protected] www.quantasystem.com