1 METALS INTERNATIONAL LIMITED ANBAI TRADING (SHANGHAI) Co.,LTD. L, 5/F, Liaoshen International Bldg,1068 Wuzhong Rd., Shanghai 201103 China Tel: +86-21-6090-0836/60900837/6563 Fax: +86-21-6090-0838 http://www.klsteel.comEmail: [email protected] [email protected]

Upload: vulien

Post on 05-Jun-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

1

METALS INTERNATIONAL LIMITED

ANBAI TRADING (SHANGHAI) Co.,LTD.

L, 5/F, Liaoshen International Bldg,1068 Wuzhong Rd., Shanghai 201103 China

Tel: +86-21-6090-0836/60900837/6563 Fax: +86-21-6090-0838

Hhttp://www.klsteel.comUH Email: [email protected] [email protected]

Page 2: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

2

Company Profile

Metals International Limited is a reliable exporter and supplier of a wide

range of copper and copper alloy tubes, rods, bars, strips and profiles. Our

wide range of products includes Copper Tubes for Air Conditioning and

Refrigeration, Copper Tubes for Other Applications and Copper Alloys

Tubes. Adding on, we also offer Copper Bus Bar, Profiles and Rods, Copper

Coils and Strip and Plates for Earthing System as well as Copper Fittings.

All of our products are in full compliance with ASTM B68, ASTM B75,ASTM

B88, ASTM B111/ 111M ,ASME SB111/M,ASTM B280, ASTM A360, ASTM

B306, ASTM B743, ASTM A836,ASTM 837,ASME B16.22, BS 359,BS 864, BS

2871,BS EN1057, BS EN12737, BS EN12449, AS 1432, AS/NZ 1571, AS

1572,NZS 3501, GB/T 1527-2006, GB/T 8890-1998, JIS H3300:1997 etc. and

widely applied to various industries such as ACR, boiler construction, water,

gas and oil field.

Company is committed to quality products and also treasures its employees

who make it happen. Its vast organizational strength comprises of dedicated

and skilled teammates whose core competence lies in making a good

products, a better one.

With consistent strategic policy and continuous growth, Metals International

Limited has emerged out as a prominent player in the league of world-class

corporation of metals in the Global market. The organization has been

expanding, integrating and growing at the speed of light the fulfill the

ambition of its Global excellence. The establishment of Shanghai office had

been a major milestone in the path of progress of the Group.

Our goal is to provide quality products to our customers at competitive

prices with best service that will ensure long-term relationships with our

customers.

Page 3: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

3

Specification

Type Usage Size Alloy Number Standard

O.D. (mm) W.T. (mm) ASTM EN JIS BS AS Welded

Copper

Tube

ACR 6-105 0.4-8 C12200/

C1220/CU-DHP ASTM B280 EN12735 JIS3300 BS1057 AS/NZS1571 ASTM B640

Water Tube 9-300 0.4-60 C12200 /CU-DHP/

CW024A/K/L/M

ASTM B88

/ANSI/NSF61/ASTM B698 EN1057 JIS3300 BS1057 NZS3501 ASTM B466

Copper Drainage

Tube(DWV) 9-300 0.4-60 C12200 ASTM B306 EN1057 JIS C1220 BS1057 AS1432 ASTM B467

ACR, GAS Pipe 9-76 0.4-8 C12000/C12200/C1020

0 ASTM B68 /ASTM B837 EN1057 JIS3300 BS1057 NZS3501

Condenser &

Heat Exchanger 6-108 0.4-8 C12200 ASTM B75 /ASTM 359 EN 12451 JIS3300 BS1057 AS2378

ASTM 395

/ASTM B543

Electrical Tube 9-76 0.4-8 EN13600 BS13600 ASTM B447

Medical &

Vacuum 9-300 0.4-60 ASTM B819 EN13348

BS 1057/

BS2871

Copper

Fittings

ACR/Pipe/Gaslin

e Pipe fittings 6-108 0.4-8 C12200 ASME B16.22 EN1254 JISH3401 BS864-2

Brass

Tube

Admiralty Brass

Tube 4-100 0.4-12

C44300/ CuZn28Sn1/

HSn70-1 ASTM111 EN 12451 JIS3300 BS1057 AS1569

Page 4: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

4

Common Brass

Tube 4-100 0.4-12 C27200/C27400 ASTM B135 EN 12451 JIS3300 BS1057

Aluminum Brass

Tube 4-100 0.4-12 C68700/C6870/ CZ110 ASTM B359 EN 12451 JIS3300 BS1057 AS1569

Copper-

Nickel

Tube

90/10 Cu-Ni Tube 4-100 0.4-12 C70600/C7060/ CN102 ASTM B111/ASTM B3466 EN 12451 JIS3300 BS1057 AS1569

70/30 Cu-Ni Tube 4-100 0.4-12 C71500/C7150/

CN107/C26000 ASTM B111/ASTM B3466 EN 12451 JIS3300 BS1057 AS1572

4-100 0.4-12 C71640 ASTM B111/ASTM B3466 EN 12451 JIS3300 BS1057 AS1569

Insulate

d Coils

6.35-19.05

/24-41

0.8-1.22/8-

10 ASTM B743 AS1571

Page 5: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

5

Manufacturing Process CASTING

Copper cathode is heated to melting point then cast into copper billets in a

modern remelt and casting facility. Precise control is maintained over metal

composition and billet quality is assured by skilled casthouse and on-site

laboratory personnel.

EXTRUSION

A 3,500 tonne hydraulic extrusion press converts the solid copper billets into

long tubular "shells" by forcing the preheated billet through a die and over a

piercing mandrel. Crane Copper Tube production and engineering excellence

has resulted in innovative extrusion techniques which produce shells of

superior dimensional and compositional uniformity enabling subsequent cold

drawing to finished dimensions with precise tolerances.

Page 6: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

6

DRAWING

Cold drawing of the shell is carried out on an extensive array of specialised

equipment. Specially designed cold drawing machines called "bullblocks"

economically produce large quantities of thin-walled tube whilst larger diameter

and thick-walled tubes are rapidly produced on multi-die "drawbenches". Close

supervision by process operators and staff ensures tube of the desired

dimensional and mechanical properties.

FINISHING

The cold-drawn tubing is conveyed to "finishing lines" which manipulate and

cut the tube to produce a product of the required form and length. All tube is

inspected for defects using on-line eddy current analysis which ensures that

only flawless tube is packed and shipped from the mill.

Page 7: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

7

ANNEALING

The temper of some tube is modified using annealing ovens which maintain

strict control over temperature and furnace atmosphere resulting in product

without discolouration and with those mechanical properties desired by the

customer.

LAGGING

Copper tube is fed through a specially designed cross-head plastic extruder

which applies a plastic coating in plain or castellated form. This provides the

customer with a cost effective prelagged copper tube.

Page 8: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

8

BS EN 1057

BS EN 1057 has replaced the British Standard BS 2871 Part 1 and other conflicting standards previously used. This

standardization with EN 1057 has provided a common standard for many markets. However, as there are no

dimensional changes, all EN 1057 tube is totally compatible with current BS tube and fittings.

EN 1057 - TYPE Y (PREVIOUSLY BS 2871 TABLE Y)

Size Nom. Dia.

(Outside)

Nom. Wall

Thickness

Max. Working Pressures*

Half Hard Hard Annealed

mm mm mm bar+ bar+ bar+

6

8

10

12

15

18

22

28

35

42

54

66.7

76.1

108

6

8

10

12

15

18

22

28

35

42

54

66.7

76.1

108

0.8

0.8

0.8

0.8

1.0

1.0

1.2

1.2

1.5

1.5

2.0

2.0

2.0

2.5

188

136

106

87

87

72

69

55

54

45

47

37

33

29

223

161

126

104

104

85

84

65

65

54

56

45

39

34

144

105

82

67

67

55

53

42

41

34

36

28

25

22

*Based on designated temper at 65°C +1 bar = 0.1N/mm² = 105 N/m²

Usage: Underground works and heavy duty requirements including hot and cold water

supply, gas reticulation, sanitary plumbing, heating and general engineering.

ADDED

TOUGHNESS &

DURABILITY

Page 9: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

9

EN 1057 - TYPE X (PREVIOUSLY BS 2871 TABLE X)

Size Nom. Dia.

(Outside)

Nom. Wall

Thickness

Max. Working Pressures*

Half Hard Hard Annealed

mm mm mm bar+ bar+ bar+

6

8

10

12

15

18

22

28

35

42

54

66.7

76.1

108

133

159

6

8

10

12

15

18

22

28

35

42

54

66.7

76.1

108

133

159

0.6

0.6

0.6

0.6

0.7

0.8

0.9

0.9

1.2

1.2

1.2

1.2

1.5

1.5

1.5

2.0

133

97

77

63

58

56

51

40

42

35

27

20

24

17

14

15

161

118

93

76

71

67

62

48

51

43

33

27

29

20

17

18

102

75

59

48

45

43

39

31

33

27

21

17

18

13

10

12

*Based on designated temper at 65°C +1 bar = 0.1N/mm² = 105 N/m²

Usage: Above groundservices including drinking water supply, hot and cold water

systems, sanitation, central heating and other general purpose applications.

ECONOMICAL

AND

STRONG

Page 10: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

10

EN 1057 - TYPE Z (PREVIOUSLY BS 2871 TABLE X)

Size Nom. Dia.

(Outside)

Nom. Wall

Thickness Max. Working Pressures*

mm mm mm bar+

6

8

10

12

15

18

22

28

35

42

54

66.7

76.1

108

133

159

6

8

10

12

15

18

22

28

35

42

54

66.7

76.3

108

133

159.5

0.5

0.5

0.5

0.5

0.5

0.6

0.6

0.6

0.7

0.8

0.9

1.0

1.2

1.2

1.5

1.5

113

98

78

64

50

50

41

32

30

28

25

20

19

17

16

15

*Based on material in hard drawn condition at 65°C +1 bar = 0.1N/mm² = 105 N/m²

Usage: Above groundservices including drinking water supply, hot and cold water

systems, sanitation, central heating and other general purpose applications.

LOW COST

UTILITY

RANGE

MECHANICAL PROPERTIES OF TUBE TO EN 1057

Temper Nom. Dia.

(Outside) MPa*

Minimum

Elongation Hardness**

R220 Annealed

R250 Half Hard

R250 Half Hard

R290 Hard

6 to 54mm

6 to 66.7mm

6 to 159mm

6 to 267mm

220

250

250

290

40%

30% #

20% #

3%

40 to 70

75 to 100

75 to 100

100 min

# Note: Elongations for half hard tubes depend on the ratio of outside diameter to wall thickness.

* MPa: Minimum tensile strength ** Hardness HV/5 indicative

Page 11: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

11

ASTM B88 : 99 (Copper Water and Gas Tube)

This specification covers hard drawn temper, seamless copper tubes which are suitable for use in general

plumbing applications, such as underground water service, potable water distribution, gas distribution and fire

sprinkler installations.

To assist with selection this standard is separated into three Types - K, L and M. Each type is differentiated by a

range of wall thicknesses, with Type K having thicker walls than Type L, and Type L being thicker than Type M, for

any given diameter.

TYPE K

Nom.

Size (")

Dimensions (")

Calculated Values (Based on ASME B31)

*Rated internal working pressures (psi)

Nom. Weight

(lbs per ft)

Actual

Wall

Thickness

Surface Temperature

Outside Diameter

Up to 150°F 300°F

Annealed Hard Drawn Annealed Hard Drawn

1/4

3/8

1/2

5/8

3/4

1

2

3

4

5

6

8

.375

.500

.625

.750

.875

1.125

1.375

1.625

2.125

2.625

3.125

3.625

4.125

5.125

6.125

8.125

3/8

1/2

5/8

3/4

7/8

1 1/8

1 3/8

1 5/8

2 1/8

2 5/8

3 1/8

3 5/8

4 1/8

5 1/8

6 1/8

8 1/8

.035

.049

.049

.049

.065

.065

.065

.072

.083

.095

.109

.120

.134

.160

.192

.271

913

979

769

633

735

563

456

424

372

341

330

313

308

295

296

315

2029

2135

1683

1389

1609

1236

1003

933

820

751

579

549

540

517

520

554

842

902

709

583

662

520

420

391

343

314

304

288

283

272

272

290

1974

2077

1638

1351

1566

1203

976

908

798

731

560

531

522

500

502

535

0.145

0.269

0.344

0.419

0.642

0.839

1.037

1.362

2.065

2.928

4.005

5.124

6.516

9.678

13.878

25.930

Page 12: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

12

TYPE L

Nom.

Size (")

Dimensions (")

Calculated Values (Based on ASME B31)

*Rated internal working pressures (psi)

Nom. Weight

(lbs per ft)

Actual

Wall

Thickness

Surface Temperature

Outside Diameter

Up to 150°F 300°F

Annealed Hard Drawn Annealed Hard Drawn

1/4

3/8

1/2

5/8

3/4

1

2

3

4

5

6

8

.375

.500

.625

.750

.875

1.125

1.375

1.625

2.125

2.625

3.125

3.625

4.125

5.125

6.125

8.125

3/8

1/2

5/8

3/4

7/8

1 1/8

1 3/8

1 5/8

2 1/8

2 5/8

3 1/8

3 5/8

4 1/8

5 1/8

6 1/8

8 1/8

.030

.035

.040

.042

.045

.050

.055

.060

.070

.080

.090

.100

.110

.125

.140

.200

775

662

614

536

495

420

373

347

309

286

269

258

249

229

213

230

1722

1471

1362

1192

1099

933

828

771

686

633

476

456

440

404

376

406

714

610

565

494

456

387

344

319

285

263

248

238

229

211

197

211

1676

1431

1325

1160

1069

908

806

750

667

616

449

441

425

391

364

393

0.126

0.198

0.286

0.362

0.448

0.655

0.885

1.144

1.753

2.480

3.328

4.295

5.381

7.615

10.208

19.310

Page 13: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

13

TYPE M

Nom.

Size (")

Dimensions (")

Calculated Values (Based on ASME B31)

*Rated internal working pressures (psi)

Nom. Weight

(lbs per ft)

Actual

Wall

Thickness

Surface Temperature

Outside Diameter

Up to 150°F 300°F

Annealed Hard Drawn Annealed Hard Drawn

3/8

1/2

3/4

1

2

3

4

5

6

8

.500

.625

.875

1.125

1.375

1.625

2.125

2.625

3.125

3.625

4.125

5.125

6.125

8.125

1/2

5/8

7/8

1 1/8

1 3/8

1 5/8

2 1/8

2 5/8

3 1/8

3 5/8

4 1/8

5 1/8

6 1/8

8 1/8

.025

.028

.032

.035

.042

.049

.058

.065

.072

.083

.095

.109

.122

.170

485

420

346

286

287

281

254

233

215

214

313

198

185

195

1077

932

769

636

638

625

563

517

380

378

377

349

328

344

446

387

319

264

265

259

234

215

198

197

197

182

171

179

1048

907

748

619

621

608

548

503

367

366

365

337

317

333

0.144

0.204

0.328

0.465

0.682

0.940

1.460

2.027

2.678

3.582

4.664

6.661

8.922

16.475

* Annealed S = 5,100psi, Hard Drawn S = 11,300psi, for sizes ¼" to 2½" Nominal. S = 8,700psi for sizes over 2½" Nominal, as these

sizes are not normally available in the annealed form and are not therefore covered by ASME.

The figures provided are for guidance only, based on the indicated temperatures.

Page 14: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

14

ASTM B280 : 99 (Seamless Copper Tube for Airconditioning and Refrigeration Field Service)

These tubes are supplied in both hard drawn straight lengths and annealed coils, after meticulous cleaning,

dehydrating and capping to ensure that the internal cleanliness standards are fully met. The intended use is in

the installation, repair, or alteration of airconditioning and refrigeration units.

STRAIGHT LENGTHS

Standard

Size, in.

Outside Dia.

in. (mm)

Wall Thickness

in. (mm)

Weight, lb/ft

(kg/m)

Nom. Weight,

kgs 5.8 metres

* Safe Working

internal pressures

PSI (KPa) 150°F

3/8

1/2

5/8

3/4

7/8

1 1/8

1 3/8

1 5/8

2 1/8

2 5/8

3 1/8

3 5/8

4 1/8

0.375 (9.52)

0.500 (12.7)

0.625 (15.9)

0.750 (19.1)

0.875 (22.2)

1.125 (28.6)

1.375 (34.9)

1.625 (41.3)

2.125 (54.0)

2.625 (66.7)

3.125 (79.4)

3.625 (92.1)

4.125 (104.8)

0.030 (0.76)

0.035 (0.89)

0.040 (1.02)

0.042 (1.07)

0.045 (1.14)

0.050 (1.27)

0.055 (1.40)

0.060 (1.52)

0.070 (1.78)

0.080 (2.03)

0.090 (2.29)

0.100 (2.54)

0.110 (2.79)

0.126 (0.187)

0.198 (0.295)

0.285 (0.424)

0.362 (0.539)

0.455 (0.677)

0.655 (0.975)

0.884 (1.317)

1.14 (1.703)

1.75 (2.609)

2.48 (3.692)

3.33 (4.954)

4.29 (6.393)

5.38 (8.010)

1.09

1.71

2.46

3.13

3.92

5.65

7.65

9.85

15.13

21.42

28.73

37.08

46.45

810 (5585)

675 (4654)

625 (4310)

545 (3758)

495 (3415)

440 (3035)

385 (2655)

355 (2450)

315 (2170)

295 (2035)

275 (1895)

270 (1860)

255 (1760)

ANNEALED COIL

Standard

Size, in.

Outside Dia.

in. (mm)

Wall Thickness

in. (mm)

Weight, lb/ft

(kg/m)

Nom. Weight,

kgs 15 metres

* Safe Working

internal pressures

PSI (KPa) 150°F

3/16

1/4

5/16

3/8

1/2

5/8

3/4

3/4

7/8

1 1/8

1 3/8

0.187 (4.76)

0.250 (6.35)

0.312 (7.92)

0.375 (9.52)

0.500 (12.7)

0.625 (15.9)

0.750 (19.1)

0.750 (19.1)

0.875 (22.2)

1.125 (28.6)

1.375 (34.9)

0.030 (0.76)

0.030 (0.76)

0.032 (0.81)

0.032 (0.81)

0.032 (0.81)

0.035 (0.89)

0.035 (0.89)

0.042 (1.07)

0.045 (1.14)

0.050 (1.27)

0.055 (1.40)

0.0575 (0.086)

0.0804 (0.120)

0.109 (0.162)

0.134 (0.199)

0.182 (0.271)

0.251 (0.373)

0.305 (0.454)

0.362 (0.539)

0.455 (0.677)

0.665 (0.975)

0.884 (1.317)

1.28

1.80

2.43

2.98

4.07

5.62

6.81

8.09

10.16

14.62

19.75

1690 (11650)

1230 (8480)

1040 (7170)

860 (5930)

630 (4344)

540 (3723)

440 (3034)

535 (3690)

500 (3450)

430 (2965)

390 (2690)

* Computed allowable stress for annealed copper tubes at the indicated temperature as determined from ASME B31.

Page 15: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

15

ASTM B306 : Copper Drainage Tube (DWV)

This specification covers seamless copper drainage tube, which is intended for use with soldered fittings for

sanitary drainage, such as soil, waste and vent piping.

TYPE DWV

Nom.

Size (")

Dimensions (")

Calculated Values (Based on ASME B31)

*Rated internal working pressures (psi)

Nom. Weight

(lbs per ft)

Actual

Wall

Thickness

Surface Temperature

Outside Diameter

Up to 150°F 300°F

Annealed Hard Drawn Annealed Hard Drawn

1 1/4

1 1/2

2

3

4

5

6

8

1.375

1.625

2.125

3.125

4.125

5.125

6.125

8.125

1 3/8

1 5/8

2 1/8

3 1/8

4 1/8

5 1/8

6 1/8

8 1/8

.040

.042

.042

.045

.058

.072

.083

.109

280

249

185

135

128

128

126

124

621

552

410

239

225

227

223

219

258

230

170

124

117

118

116

114

604

537

399

231

218

220

216

209

0.649

0.810

1.066

1.689

2.874

4.432

6.110

10.645

* Annealed 150°F S = 5,100psi, sizes 1¼" to 8"

300°F S = 4,700psi, sizes 1¼" to 8"

Hard Drawn 150°F S = 11,300psi, sizes 1¼" to 2", S = 9,00psi sizes 3" to 8"

300°F S = 11,000psi, sizes 1¼" to 2", S = 8,70psi sizes 3" to 8"

The figures provided are for guidance only, based on the indicated temperatures.

Page 16: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

16

AS 1432 : 2000 (Copper tubing for plumbing, gasfitting and drainage applications).

This standard provides for round seamless copper tubes intended for use in pressure and non-pressure plumbing,

gasfitting and drainage applications in hard drawn, bending quality, annealed, and plastic lagged coils and straight

lengths. Inert plastic lagging is available for this product coloured in green for potable drinking water and lilac for

recycled water applications.

TYPE A

NOMINAL

SIZE

NOM. DIA.

(OUTSIDE)

NOM. WALL

THICKNESS

PREVIOUS

SIZE

DN 6 *

DN 8 *

DN 10 *

DN 15 *

DN 18 *

DN 20 *

DN 25 *

DN 32 *

DN 40 *

DN 50

DN 65

DN 80

DN 90

DN 100

DN 125

DN 150

DN 200

6.4

7.9

9.5

12.7

15.9

19.1

25.4

31.8

38.1

50.8

63.5

76.2

88.9

101.6

127.0

152.4

203.2

0.9

0.9

1.0

1.0

1.2

1.4

1.6

1.6

1.6

1.6

1.6

2.0

2.0

2.0

2.0

2.6

2.6

1/4" x 20G

5/16" x 20G

3/8" x 19G

1/2" x 19G

5/8" x 18G

3/4" x 17G

1" x 16G

1¼" x 16G

1½" x 16G

2" x 16G

2½" x 16G

3" x 14G

3½" x 14G

4" x 14G

5" x 14G

6" x 12G

8" x 12G

TYPE B

NOMINAL

SIZE

NOM. DIA.

(OUTSIDE)

NOM. WALL

THICKNESS

PREVIOUS

SIZE

DN 6 *

DN 8 *

DN 10 *

DN 15 *

DN 18 *

DN 20 *

DN 25 *

DN 32 *

DN 40 *

6.4

7.9

9.5

12.7

15.9

19.1

25.4

31.8

38.1

0.7

0.7

0.9

0.9

1.0

1.0

1.2

1.2

1.2

1/4" x 22G

5/16" x 22G

3/8" x 20G

1/2" x 20G

5/8" x 19G

3/4" x 19G

1" x 18G

1¼" x 18G

1½" x 18G

Page 17: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

17

DN 50

DN 65

DN 80

DN 90

DN 100

DN 125

DN 150

DN 200

50.8

63.5

76.2

88.9

101.6

127.0

152.4

203.2

1.2

1.2

1.6

1.6

1.6

1.6

2.0

2.0

2" x 18G

2½" x 18G

3" x 16G

3½" x 16G

4" x 16G

5" x 16G

6" x 14G

8" x 14G

TYPE C

NOMINAL

SIZE

NOM. DIA.

(OUTSIDE)

NOM. WALL

THICKNESS

PREVIOUS

SIZE

DN 10 *

DN 15 *

DN 18 *

DN 20 *

DN 25 *

9.5

12.7

15.9

119.1

125.4

0.7

0.7

0.9

0.9

0.9

3/8" x 22G

1/2" x 22G

5/8" x 20G

3/4" x 20G

1" x 20G

TYPE D

NOMINAL

SIZE

NOM. DIA.

(OUTSIDE)

NOM. WALL

THICKNESS

PREVIOUS

SIZE

DN 32

DN 40

DN 50

DN 65

DN 80

DN 90

DN 100

DN 125

DN 150

31.8

38.1

50.8

63.5

76.2

88.9

101.6

127.0

152.4

0.9

0.9

0.9

0.9

1.2

1.2

1.2

1.4

1.6

1¼" x 20G

1½" x 20G

2" x 20G

2½" x 20G

3" x 18G

3½" x 18G

4" x 18G

5" x 17G

6" x 16G

DN = DIMENSIONLESS NUMBER

Standard Lengths

Straights up to and including: DN 125 outside diameter - 6 metres

DN 150 and over - Random 4 to 6 metres

* Available as annealed coil: DN 8 and below - 30 metre lengths

DN 10 and above - 18 metre lengths

Page 18: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

18

AS 1571 : 1995 (Copper - Seamless tubes for airconditioning and refrigeration).

These tubes are supplied in both hard drawn straight lengths and annealed coils, after meticulous cleaning,

dehydrating and capping, to ensure that the internal cleanliness standards are fully met. The intended use for this

product is in airconditioning and refrigeration applications.

STRAIGHT LENGTHS

Size

(mm)

Inches

& SWG

Nominal

kg/m

* Safe Working Pressure KPa

SD = 33.9

50-75°C

SD = 32.7

100-125°C

SD = 28.0

150-175°C

SD = 21.9

175-200°C

6.4 x 0.91

9.5 x 0.91

12.7 x 1.02

12.7 x 0.91

15.9 x 0.91

19.1 x 1.02

19.1 x 0.91

22.2 x 1.22

22.2 x 0.91

25.4 x 1.22

25.4 x 0.91

28.6 x 1.22

28.6 x 0.91

31.8 x 1.22

31.8 x 0.91

34.9 x 1.22

34.9 x 0.91

38.1 x 1.22

38.1 x 0.91

41.3 x 1.22

41.3 x 0.91

44.5 x 1.22

44.5 x 0.91

50.8 x 1.63

50.8 x 1.22

50.8 x 0.91

54.0 x 1.63

54.0 x 1.22

54.0 x 0.91

1/4" x 20

3/8" x 20

1/2" x 19

1/2" x 20

5/8" x 20

3/4" x 19

3/4" x 20

7/8" x 18

7/8" x 20

1" x 18

1" x 20

1 1/8" x 18

1 1/8" x 20

1 1/4" x 18

1 1/4" x 20

1 3/8" x 18

1 3/8" x 20

1 1/2" x 18

1 1/2" x 20

1 5/8" x 18

1 5/8" x 20

1 3/4" x 18

1 3/4" x 20

2" x 16

2" x 18

2" x 20

2 1/8" x 16

2 1/8" x 18

2 1/8" x 20

0.139

0.221

0.335

0.302

0.383

0.416

0.464

0.721

0.545

0.829

0.626

0.938

0.708

1.047

0.789

1.156

0.870

1.265

0.951

1.373

1.032

1.483

1.114

2.253

1.700

1.276

2.398

1.809

1.357

9950

6395

5280

4670

3680

3420

3035

3525

2600

3060

2260

2700

2000

2425

1790

2200

1630

2010

1490

1850

1370

1700

1270

2015

1495

1110

1890

1400

1045

9590

6170

5095

4500

3550

3300

2930

3400

2500

2950

2180

2600

1925

2340

1725

2125

1570

1940

1435

1785

1320

1650

1225

1945

1445

1070

1825

1350

1000

8200

5280

4360

3860

3040

2825

2500

2900

2145

2530

1865

2235

1650

2000

1480

1820

1345

1660

1230

1530

1130

1415

1050

1665

1235

915

1560

1160

860

6425

4130

3400

3020

2380

2200

1960

2280

1675

1980

1460

1750

1290

1565

1155

1420

1050

1300

960

1195

885

1100

820

1300

965

715

1220

900

675

Page 19: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

19

66.7 x 1.63

66.7 x 1.22

76.2 x 1.63

101.6 x 1.63

2 5/8" x 16

2 5/8" x 18

3" x 16

4" x 16

2.981

2.245

3.417

4.581

1520

1135

1330

990

1470

1095

1280

955

1260

935

1100

820

985

730

860

640

ANNEALED COIL

Size

(mm)

Inches

& SWG

Nominal

kg/m

* Safe Working Pressure KPa

SD = 33.9

50-75°C

SD = 32.7

100-125°C

SD = 28.0

150-175°C

SD = 21.9

175-200°C

4.8 x 0.91

4.8 x 0.71

4.8 x 0.56

6.4 x 1.22

6.4 x 0.91

6.4 x 0.71

6.4 x 0.56

7.9 x 0.91

7.9 x 0.71

7.9 x 0.56

9.5 x 0.91

9.5 x 0.71

9.5 x 0.56

12.7 x 0.91

12.7 x 0.81

12.7 x 0.71

12.7 x 0.56

15.9 x 0.91

15.9 x 0.81

15.9 x 0.71

15.9 x 0.56

19.1 x 0.91

19.1 x 0.71

22.2 x 0.91

3/16 x 20

3/16 x 22

3/16 x 24

1/4 x 18

1/4 x 20

1/4 x 22

1/4 x 24

5/16 x 20

5/16 x 22

5/16 x 24

3/8 x 20

3/8 x 22

3/8 x 24

1/2 x 20

1/2 x 21

1/2 x 22

1/2 x 24

5/8 x 20

5/8 x 21

5/8 x 22

5/8 x 24

3/4 x 20

3/4 x 22

7/8 x 20

0.098

0.081

0.066

0.176

0.139

0.113

0.091

0.180

0.144

0.116

0.221

0.176

0.141

0.302

0.271

0.239

0.191

0.383

0.343

0.303

0.241

0.464

0.366

0.545

13940

10400

7950

14040

9950

7520

5795

7840

5965

4620

6395

4890

3795

4670

4125

3590

2800

3680

3250

2840

2220

3030

2340

2595

13450

10040

7600

13540

9595

7250

5640

7580

5750

4450

6170

4700

3660

4500

3980

3460

2700

3550

3140

2740

2144

2930

2260

2500

11520

8600

6560

11600

8215

6200

4830

6470

4920

3800

5280

4030

3130

3860

3400

2965

2315

3040

2690

2340

1835

2500

1940

2145

9000

6700

5100

9000

6400

4850

3775

5060

3850

2980

4100

3150

2450

3020

2665

2320

1810

2380

2100

1830

1435

1960

1500

1670

* Safe working pressures calculated for annealed copper.

Page 20: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

20

AS 1572 : 1998 (Copper - Seamless tubes for engineering purposes).

This Standard specifies seamless copper and copper alloy tubes for general purposes. It does not apply for heat

exchangers or tubes for airconditioning.

NZS 3501 : 1976 (Copper Tubes for water, gas and sanitation)

This copper tube is manufactured in straight lengths, in half hard condition and in fully annealed coils.

Table 1 - Copper Tubes For Water and Gas

Nominal

Bore*

Outside Diameter

Thickness

Hydrostatic

test

pressure

Max. working pressure #

Max. Min. Annealed Coil Half-hard As drawn

mm mm mm mm MPa MPa F=46 MPa F=60 MPa F=70

15 (½)

20 (¾)

25 (1)

32 (1¼)

40 (1½)

50 (2)

65 (3)

80

90 (3½)

100 (4)

14.73

21.08

27.43

34.19

40.54

53.24

65.94

79.45

92.56

105.66

14.65

21.00

27.35

34.11

40.46

53.16

65.79

79.30

92.41

105.51

1.02

1.02

1.02

1.22

1.22

1.22

1.22

1.63

1.83

2.03

5.55

3.90

2.95

2.85

2.40

1.85

1.50

1.65

1.60

1.55

6.85

4.70

-

-

-

-

-

-

-

-

8.95

6.10

4.65

4.45

3.70

2.80

-

-

-

-

-

-

-

-

-

-

2.65

2.95

2.80

2.75

Table 2 - Copper Tubes For Sanitation

Nominal

Bore*

Outside Diameter

Thickness

Hydrostatic

test

pressure

Max. working pressure #

Max. Min. Annealed Coil Half-hard As drawn

mm mm mm mm MPa MPa F=46 MPa F=60 MPa F=70

25 (1)

32 (1¼)

40 (1½)

50 (2)

65 (2½)

80 (3)

90 (3½)

27.43

34.19

40.54

53.24

65.94

79.04

92.15

27.35

34.11

40.46

53.16

65.79

78.89

92.00

1.02

1.22

1.22

1.22

1.22

1.42

1.63

2.95

2.85

2.40

1.85

1.50

1.45

1.40

-

-

-

-

-

-

-

4.65

4.45

3.75

2.80

-

-

-

-

-

-

-

2.65

2.55

2.50

Page 21: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

21

100 (4)

125 (5)

150 (6)

200 (8)

104.85

130.25

156.06

194.50

104.70

130.00

155.76

194.25

1.63

1.63

1.83

3.00

1.25

1.00

0.95

1.25

-

-

-

-

-

-

-

-

2.20

1.80

1.65

2.20

Table 3 - Light Gauge Copper Tubes For Water and Gas

Nominal

Bore*

Outside Diameter

Thickness

Hydrostatic

test

pressure

Max. working pressure #

Max. Min. Annealed Coil Half-hard As drawn

mm mm mm mm MPa MPa F=46 MPa F=60 MPa F=70

15 (½)

20 (¾)

14.73

21.08

14.65

21.00

0.7

0.9

3.80

3.40

-

-

6.00

5.35

-

-

* The figures in brackets are the previous imperial inch dimensions

# Maximum working pressure at temperatures up to 65°C, from the following formula:

P=

2Ft

D-t

WHERE: P = PRESSURE (MPa)

F = ALLOWABLE STRESS FACTOR (MPa)

t = THICKNESS (mm)

D = OUTSIDE DIAMETER (mm)

Page 22: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard
Page 23: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard
Page 24: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard
Page 25: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard
Page 26: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard
Page 27: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

MIL Catalogue for the Copper Fittings:

Page 28: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

1.Solder Joint Copper Fittings-ANSI/ASME B16.22-2001

C X CMueller Style: WE-500 5/8″Elkhart Style: 107-C 3/4″ O.D. SizeNibco Style: 9607-1 7/8″ 1/4″

1″ 3/8″1-1/8″ 1/2″1-1/4″ 5/8″1-3/8″ 3/4″1-1/2″ 7/8″1-5/8″ 1″1-3/4″ 1-1/8″2-1/8″ 1-3/8″2-5/8″ 1-5/8″

O.D. Size 3-1/8″ 2-1/8″1/4″ 3-5/8″ 2-5/8″

5/16″ 4-1/8″ 3-1/8″3/8″ 5-1/8″ 3-5/8″1/2″ 6-1/8″ 4-1/8″

5/8″3/4″ O.D. Size7/8″ 1/4″1″ 3/8″

1-1/8″ 1/2″1-1/4″ 5/8″1-3/8″ 3/4″1-1/2″ 7/8″1-5/8″ 1″1-3/4″ 1-1/8″2-1/8″ 1-3/8″2-5/8″ 1-5/8″

O.D. Size 3-1/8″ 2-1/8″1/4″ 3/5/8″ 2-5/8″

5/16″ 4/1/8″ 3-1/8″3/8″ 5-1/8″ 3-5/8″1/2″ 6-1/8″ 4-1/8″

Nibco style:9606-2

FTG X C

45ºElbow

Nibco style:9606

Mueller style:WE-505

45ºElbowC X C

Mueller style:WE-504

Elkhart style:106

90ºElbow-Short Radius

FTG X CMueller Style: WE-503Elkhart Style: 107-C-2Nibco Style: 9607-2

90ºElbow-Short Radius

Elkhart style:106-2

Copper Fittings Supplier

Page 29: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

1/2″5/8″ 1/2″3/4″ 5/8″7/8″ 3/4″1″ 7/8″

1-1/8″ 1″1-1/4″ 1-1/8″1-3/8″ 1-1/4″1-5/8″ 1-3/8″2-1/8″ 1-5/8″2-5/8″ 2-1/8″

O.D. Size 3-1/8″ O.D. Size 2-5/8″1/4″ 3-5/8″ 1/4″ 3-1/8″3/8″ 4-1/8″ 3/8″ 4-1/8″

O.D. Size3/4″ 1/4"7/8″ 3/8"1″ 1/2"

1-1/8″ 5/8"1-1/4″ 3/4"1-3/8″ 7/8"1-1/2″ 1-1/8"1-5/8″ 1-3/8"1-3/4″ 1-5/8"2-1/8″ 2-1/8"

O.D. Size 2-5/8″ 2-5/8"1/4″ 3-1/8″ 3-1/8"

5/16″ 3-5/8″ 4-1/8"3/8″ 4-1/8″1/2″ 5-1/8″5/8″ 6-1/8″

Elkhart style:11

Nibco style:9611

Cap C

Elkhart Style: 117Nibco Style: 9617

Mueller Style: WC-415Equal Tee C X C X CMueller style:WT-600

90ºElbow-Long RadiusC X C

Mueller style:WE-500L

90ºElbow-long RadiusFTG X C

Mueller style:WE-503L

Elkhart style:107-L

Nibco style:9607-L

Elkhart style:107-L-2

Nibco style:9607-2-LT

Page 30: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

1-3/8 x1-3/8 x 5/8

Reducing Tee C X C X C

3-1/8 x 3-1/8 x 1-1/83-1/8 x 3-1/8 x 1-3/8

3-1/8 x 3-1/8 x 2-5/8

1-3/8 x1-3/8 x 7/8

3-1/8 x 3-1/8 x 2-1/83-1/8 x 3-1/8 x 1-5/8

2-5/8 x 2-5/8 x 1-1/8

7/8 x 7/8 x 3/47/8 x 7/8 1-1/8

O.D. Size O.D. Size

2-5/8 x 2-5/8 x 5/8

4-1/8 x 4-1/8 x 3-1/8

4-1/8 x 4-1/8 x 1-1/8

2-5/8 x 2-5/8 x 2-1/8

1-1/8 x 7/8 x 7/81-1/8 x 1-1/8 x 3/8

7/8 x 5/8 x 7/8 3-1/8 x 3-1/8 x 7/8

1-1/8 x 7/8 x 5/8

7/8 x 7/8 x 5/8

Elkhart style:11

Nibco style:9611

Mueller style:WT-600

1-3/8 x1-3/8 x 1-5/81-3/8 x1-3/8 x 1-1/8

5-1/8 x 5-1/8 x 4-1/8

1-5/8 x 1-5/8 x 2-5/84-1/8 x 4-1/8 x 1-1/84-1/8 x 4-1/8 x 1-3/84-1/8 x 4-1/8 x 1-5/8

5/8 x 1/2 x 1/24-1/8 x 4-1/8 x 2-5/8

1-3/8 x1-3/8 x 3/8

1-1/8 x 1-1/8 x 1-3/81-1/4 x 1-1/4 x 1

1-3/8 x 1-1/8 x 1-1/8

1-1/8 x 1-1/8 x 1

6-1/8 x 6-1/8 x 4-1/86-1/8 x 6-1/8 x 5-1/8

4-1/8 x 4-1/8 x 2-1/8

5/8 x 5/8 x 3/4

1-1/8 x 1-1/8 x 7/8

1-1/8 x 5/8 x 5/8

4-1/8 x 4-1/8 x 1-5/84-1/8 x 4-1/8 x 2-1/84-1/8 x 4-1/8 x 2-5/8

6-1/8 x 6-1/8 x 3-1/8

4-1/8 x 4-1/8 x 3-1/85-1/8 x 5-1/8 x 3-1/85-1/8 x 5-1/8 x 4-1/8

5-1/8 x 5-1/8 x 3-1/8

6-1/8 x 6-1/8 x 3-1/8

1-3/8 x 7/8 x 7/81-5/8 x 1-3/8 x 1-3/81-5/8 x 1-5/8 x 5/8

1-5/8 x 1-5/8 x 2-1/8

7/8 x 5/8 x 5/8

2-5/8 x 2-5/8 x 1-3/82-5/8 x 2-5/8 x 1-5/8

1-3/8 x1-3/8 x 1/2

1-1/8 x 1-1/8 x 1/21-1/8 x 1-1/8 x 5/81-1/8 x 1-1/8 x 3/4

6-1/8 x 6-1/8 x 4-1/86-1/8 x 6-1/8 x 5-1/8

4-1/8 x 4-1/8 x 1-3/8

7/8 x 7/8 x 3/87/8 x 7/8 x 1/2

5/8 x 5/8 x 7/83/4 x 5/8 x 5/83/4 x 3/4 x 3/83/4 x 3/4 x 1/23/4 x 3/4 x 5/83/4 x 5/8 x 3/4

5/8 x 3/8 x 5/85/8 x 5/8 x 1/45/8 x 5/8 x 3/85/8 x 5/8 x 1/2

5/16 x 5/16 x 1/43/8 x 3/8 x 1/43/8 x 1/4 x 3/8

3/8 x 3/8 x 5/161/2 x 3/8 x 1/41/2 x 1/2 x 1/41/2 x 1/2 x 3/85/8 x 3/8 x 1/2

Page 31: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

Coupling O.D. Size 1-1/8 x 3/8

1/4" 1-1/8 x 1/2

5/16" 1-1/8 x 5/8

3/8" 1-1/8 x 3/41/2" 1-1/8 x 7/85/8" 1-1/8 x 13/4" 1-3/8 x 3/87/8" 1-3/8 x 1/21" 1-3/8 x 5/8

1-1/8" 1-3/8 x 3/41-1/4" 1-3/8 x 7/8

1-3/8"" 1-3/8 x 1-1/81-1/2" 1-5/8 x 5/81-5/8" 1-5/8 x 3/41-3/4" 1-5/8 x 7/8

2-1/8" 1-5/8 x 1-1/8

2-5/8" 1-5/8 1-3/8

3-1/8" 2-1/8 x 1/2C X C 3-5/8" 2-1/8 x 5/8

4-1/8" 2-1/8 x 7/85-1/8" 2-1/8 x 1-1/86-1/8" 2-1/8 x 1-3/8

2-1/8 x 1-5/82-5/8 x 5/82-5/8 x7/8

2-5/8 x 1-1/82-5/8 x 1-3/82-5/8 x 1-5/8

O.D. Size 2-5/8 x 2-1/81/4 x 3/16 3-1/8 x 1-1/83/8 x 1/4 3-1/8 x 1-3/8

1/2 x 1/4 3-1/8 x 1-5/8

C X C 1/2 x 5/16 3-1/8 x 2-1/81/2 x 3/8 3-1/8 x 2-5/85/8 x 1/4 3-5/8 x 3-1/85/8 x 3/8 4-1/8 x 1-1/85/8 x 1/2 4-1/8 x 1-3/83/4 x 3/8 4-1/8 x 1-5/83/4 x 1/2 4-1/8 x 2-1/83/4 x 5/8 4-1/8 x 2-5/87/8 x 1/4 4-1/8 x 3-1/87/8 x 3/8 4-1/8 x 3-5/87/8 x 1/2 4-1/8x 2-1/87/8 x 5/8 5-1/8 x 3-1/87/8 x 3/4 5-1/8 x 4-1/8

Elkhart Style: 100

Elkhart Style: 101

Nibco Style: 9600-DS

Coupling

C X C – Staked Stop

Nibco Style: 9601

–Rolled StopCoupling

Coupling-No Stop

Elkhart Style: 100Nibco Style:9600-RS

Mueller Style: WC-400NS

Mueller Style: WC-400

Mueller Style: WC-400S Elkhart Style: 101-R

Reducing Coupling

Fitting ReducerFTG X C

Nibco Style: 9600-2Elkhart Style: 118Mueller Style: WC-403

Mueller Style: WC-400R

Nibco Style: 9600

C X C

Page 32: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

Return BendC X C C X C

1/2×1-1/2 1-3/8 x 7/81/2×3 1-3/8 x 1-1/8

5/8×1-7/8 1-5/8 x 1-1/85/8×2 1-5/8 x 1-3/8

5/8×2-1/4 2-1/8 x 1-1/83/4×2-1/2 2-1/8 x 1-3/87/8×2-1/2 2/1/8 x 1-5/81-1/8×3 2-5/8 x 1-1/8

1-1/8×3-1/4 2-5/8 x 1-3/81-3/8×3 2-5/8 x1-5/8

1-3/8×3-3/4 2-5/8 x 2-1/8O.D. Size 1-3/8×4 O.D. Size 3-1/8 x 1-5/8

1/4×1 1-5/8×3-1/2 5/8 x 1/2 3-1/8 x 2-1/83/8×1-1/2 1-5/8×4-1/2 7/8 x 5/8 3-1/8 x 2-5/83/8×4-1/2 2-1/8×5-1/2 1-1/8 x 5/8 4-1/8 x 2-5/8

1-1/8 x 7/8 4-1/8 x 3-1/8

Nominal. Size C x C O.D. Size1/4" 1/2"3/8" 5/8"1/2" 3/4"3/4" 7/8"1" 1-1/

1-1/4" 1-3/8"1-1/2" 1-5/8"

2" 2-1/8"2-1/2"

3"

4"

C X M Nominal. Size C x C O.D. Size1/4" 5/8"3/8" 3/4"1/2" 7/8"3/4" 1-1/8"1" 1-3/8"

1-1/4" 1-5/8"1-1/2" 2-1/8"

2"2-1/2"

3"4"

Reducing 90°Elbow

Mueller Style: WE-500Elkhart Style: 107-CNibco Style: 9607-1

Elkhart Style: 123Nibco Style: 9698

Mueller Style: WE-512Elkhart Style: 138

Suction Line P-Traps

Mueller Style: WE-554P

Nibco Style: 9638

Female Adapter C X FMueller Style: WC-402

Cross-Over Coupling

Nibco Style : 9636

Nibco Style: 9604

Elkhart Style: 103

Elkhart Style: 104

Nibco Style: 9603

Male Adapter

Mueller Style: WC-401

Page 33: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

Cross-Over CouplingC x C C X C

Nibco Style : 9636 O.D. Size5/8"7/8"

1-1/8"

2.Solder Ring Copper Fittings-ANSI/ASME B16.22-2001

C x C O.D. Size O.D. Size1/4 1/43/8 3/81/2 1/25/8 5/83/4 3/41 1

1-1/4 1-1/41-1/2 1-1/2

2 2

C x C O.D. Size O.D. Size1/4 1/43/8 3/81/2 1/25/8 5/83/4 3/41 1

1-1/4 1-1/41-1/2 1-1/2

2 2

Union

1-3/81-5/82-1/82-5/8

O.D. Size

1-1/8

1/25/87/8

45°Elbow 45°Elbow

FTG x C90°Elbow-Short Radius 90°Elbow-Short Radius

FTG x C

3-1/8

4-1/8

Page 34: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

O.D. Size

1/43/81/25/83/41

1-1/41-1/22

1/2 x 3/8 x 3/85/8 x 1/2 x 1/23/4 x 1/2 x 1/23/4 x 1/2 x 3/41 x 1/2 x 1/21 x 3/4 x 1/21x 3/4 x 3/4

1-1/4 x 3/4 x 3/41-1/4 x 1 x 1

O.D. Size 1-1/2 x 1-1/4 x 1-1/41/2 x 1/4 x 3/8 2 x 1-1/4 x 1-1/41/2 x 1/4 x 1/2 2 x 1-1//2 x 1-1/2

O.D. Size3/8 x 3/8 x 1/21/2 x 1/2 x 5/81/2 x 1/2 x 3/43/4 x 3/4 x 1 O.D. Size1 x 1 x1-1/4 1/4

1-1/4 x 1-1/4 x 1-1/2 3/81-1/2 x 1-1/2 x 2 1/2

5/83/41

1-1/41-1/2

2

C x C x C

Reducing Tee

TeeEqual Tee

Reducing TeeC x C x C

O.D. Size

1/2 x 1/2 x 3/8

Reducing TeeC x C x C 1/2 x1/2 x 1/4

3/8 x 3/8 x 1/4

3/4 x 3/4 x 5/81x 1x 1/21x1x5/8

5/8 x 5/8 x 1/23/4 x 3/4 x 3/8

C x C x C

1-1/2 x 1-1/2 x11-1/2 x 1-1/2 x 1-1/4

2 x 2 x 1

2 x 2 x 1-1/42 x 2 x 1-1/2

Cap C

1x1x3/41/4x1-1/4x3/4

1-1/4 x 1-1/4 x 11-1/2 x 1-1/2 x 3/4

3/4 x 3/4 x 1/2

Page 35: M INTERNATIONAL LIMITED - DIYTrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf · Copper tube is fed through a specially ... BS EN 1057 has replaced the British Standard

Nominal. Size Nominal. Size1/4 1/43/8 3/81/2 1/23/4 3/41 1

1-1/4 1-1/41-1/2 1-1/2

2 2

Reducing Coupling

C×CO.D. Size

1/43/81/25/83/41

1-1/4 Fitting Reducer1-1/2 FTG x C

Coupling-No Stop 2

5/8 x 1/2

1-1/4 x 11-1/2 x 1

2x1-1/4

Male Adapter Female Adapter

Coupling-Roll Stop C×C

C×C

C x M C x F

Coupling

3/4 x 3/83/4 x 1/23/4 x 5/8

2x 1-1/2

1-1/2 x 1-1/42x1

1 x 1/2

1x5/8

1x 3/4

1-1/4 x 5/8

1-1/4 x 3/4

5/8 x 3/8

O.D. Size

3/8 x 1/4

1/2 x 3/8