m100 shapes led direct [l10] selux · for standard shapes and sizes, lens lengths will always be...

10
Page 1 of 10 (Rev. 06/2020) M100_Shapes_Direct_1C_v1.3 In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us Project: Type: Qty: Date: Customer: M100 Shapes LED Direct Order Code: - - - - - - - - - - LED WARRANTY 5 YEAR ARRA Compliant Emergency Options DL Damp Location Rated FS In-line Fuse Driver EC Emergency Circuit Wiring (consult factory) Fixture Options DE1 5,6 Lutron 1% EcoSystem DC2 5,6,7 Lutron 1% 2-Wire DIM 5 0-10V 1% (Linear) DC5 Lutron 5% 5-Series (consult factory) 1 Values calculated from a 4’ fixture at 90 CRI, 3500K using LW shielding and a DIM driver. For additional information, please see page 2. 2 Not available with Lutron 4 1’ triangle, square and hexagon, along with 2’ triangle and square are supplied as one housing. All other sizes and shapes are supplied in multiple housings joined together in the field. 5 See page 6 for details 6 Not available in 1’ side length 7 120V only Finish WH White SV Silver Voltage * Custom colors are available, please consult factory SP Specify Premium Color 1 120 Volt 2 277 Volt U 120 through 277 50/60hz capable Light Engine CCT Shielding LW LED Optimized White Lens Mounting F 4 Surface Mount C 4 Cable S 4 Swivel Stem RS 4 Rigid Stem MI Clear Lens with Microprism 3 347 Volt (consult factory) EMR Remote Micro Inverter (consult factory) BL Semi-Matte Black Shape and Nominal Length TX QXY HX Triangle Rectangle/ Hexagon Square *X = 1’, 2’, 3’, 4’ *Y = 1’, 2’, 3’, 4’ * Select shape and add nominal side length. For rectangles, indicate length and width. Example: Use T4 for a Triangle with sides 4’ long. * For other lengths, shapes or configurations, please consult factory. L10 Multi-Mount Form 3 Consult factory for lead times 930 3000K 90+ CRI 935 3500K 90+ CRI 940 4000K 90+ CRI 927 2700K 90+ CRI 830 3 3000K 80+ CRI 827 3 2700K 80+ CRI 835 3 3500K 80+ CRI 840 3 4000K 80+ CRI DL01 5,6 eldoLED 0.1% SOLOdrive 0-10V (Logarithmic) DED 5,6 eldoLED 1% ECOdrive DALI (Logarithmic) D01 5,6 eldoLED 0.1% SOLOdrive 0-10V (Linear) DIL 5,6 eldoLED 1% ECOdrive 0-10V (Logarithmic) 1C35 1 805lm/8.7W per foot 1C30 1 643lm/7.3W per foot 1C25 1 538lm/6.1W per foot 1C20 1 445lm/4.9W per foot 1C45 1,2 944lm/11.1W per foot 1C40 1,2 852lm/9.9W per foot Series L10 L10 RGBW (consult factory)

Upload: others

Post on 18-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: M100 Shapes LED Direct [L10] selux · For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details

Page 1 of 10 (Rev. 06/2020)

M100_Shapes_Direct_1C_v1.3In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Project:

Type: Qty:

Date: Customer:

M100 ShapesLED Direct

Order Code: - - - - - - - - - -

LED WARRANTY

5YEAR ARRA

Compliant

Emergency Options

DL Damp Location Rated

FS In-line Fuse

Driver

EC Emergency Circuit Wiring (consult factory)

Fixture Options

DE15,6 Lutron 1% EcoSystem

DC25,6,7 Lutron 1% 2-Wire

DIM5 0-10V 1% (Linear)

DC5 Lutron 5% 5-Series (consult factory)

1 Values calculated from a 4’ fixture at 90 CRI, 3500K using LW shielding and a DIM driver. For additional information, please see page 2.

2 Not available with Lutron

4 1’ triangle, square and hexagon, along with 2’ triangle and square are supplied as one housing. All other sizes and shapes are supplied in multiple housings joined together in the field.

5 See page 6 for details6 Not available in 1’ side length7 120V only

Finish WH White

SV Silver

Voltage

* Custom colors are available, please consult factory

SP Specify Premium Color

1120 Volt

2277 Volt

U120 through 277 50/60hz capable

Light Engine

CCT

Shielding LW LED Optimized White Lens

Mounting F4 Surface Mount

C4 Cable

S4 Swivel Stem

RS4 Rigid Stem

MI Clear Lens with Microprism

3347 Volt (consult factory)

EMR Remote Micro Inverter (consult factory)

BL Semi-Matte Black

Shape and Nominal Length

TX QXY HX Triangle Rectangle/ Hexagon

Square

*X = 1’, 2’, 3’, 4’ *Y = 1’, 2’, 3’, 4’

* Select shape and add nominal side length. For rectangles, indicate length and width. Example: Use T4 for a Triangle with sides 4’ long.

* For other lengths, shapes or configurations, please consult factory.

L10 Multi-Mount Form

3 Consult factory for lead times930 3000K 90+ CRI

935 3500K90+ CRI

940 4000K 90+ CRI

927 2700K 90+ CRI

8303 3000K 80+ CRI

8273 2700K 80+ CRI

8353 3500K 80+ CRI

8403 4000K 80+ CRI

DL015,6 eldoLED 0.1% SOLOdrive 0-10V (Logarithmic)

DED5,6 eldoLED 1% ECOdrive DALI (Logarithmic)

D015,6 eldoLED 0.1% SOLOdrive 0-10V (Linear)

DIL5,6 eldoLED 1% ECOdrive 0-10V (Logarithmic)

1C351 805lm/8.7W per foot

1C301 643lm/7.3W per foot

1C251 538lm/6.1W per foot

1C201 445lm/4.9W per foot

1C451,2 944lm/11.1W per foot

1C401,2 852lm/9.9W per foot

SeriesL10

L10

RGBW (consult factory)

Page 2: M100 Shapes LED Direct [L10] selux · For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details

Page 2 of 10 (Rev. 06/2020)

M100_Shapes_Direct_1C_v1.3

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M100 ShapesLED DirectM100LED Direct

Construction:

Housing - Continuous, low copper 6063-T6 extruded aluminum profile available as Triangle, Square, Rectangle, or Hexagon.

Geartray - Low copper 6063-T6 extruded alumi-num profile.

Shielding - Extruded, impact resistant acrylic lens:- LED Optimized White Lens (LW)- Clear Lens with Microprism Inlay (MI)

Mounting(s) - 1/16” Aircraft Cable, Ø5/8” Swivel or Rigid Steel Stem, Wall Bracket, Surface mount-ing (see pages 3 through 6 for details).

Standard Luminaire lengths - All standard luminaires are supplied in nominal lengths to ensure full, even illumination. ** Individual luminaires are not joinable in the field.

Exact length luminaires - Sizes and shapes other than those indicated are available to meet your project needs. Please consult factory with your requirements. ** Lens luminance may soften at the corners for exact length luminaires.

L10 Joiner(s) - 1’ triange, square, and hexagon along with 2’ triangle and square supplied as one housing. All other sizes, shapes, and configurations are supplied in multiple housings joined together in the field using the supplied L10 joiner system. This allows ease of installation and ensures a uniform appearance (see page 8 for detail).

Weight: 3.2 lb. per foot based on total length.

Electrical/Performance:

LED Light Engine - Brand-name mid-power LEDs create a high efficiency LED light engine able to provide a lumen maintenance of 95% at 25,000 hours and 90% at 60,000 hours at 25ºC per TM-21 reports. Reported L70 greater than 60,000 hours.

Photometrics - Consult website or factory for IES Files. Independent photometric lumen measurement complies with IES LM-79-08 testing procedures. Due to the LED manufacturer’s tolerances, the listed output has a ±5% tolerance. For outputs based on different optics or CCT, please see pages 9-10 for details.

CCT - Available in 2700K, 3000K, 3500K and 4000K, tolerance within a 3-step MacAdam ellipse.

CRI - 90+ and 80+ CRI. Consult factory for lead times of 80 CRI.

All Drivers - High efficiency, constant current, soft start, Electronic Class 2 with a PFC>0.90. For more detailed information on the available drivers please see page 6.

Thermal Performance:

Ambient Operating Temperature - Luminaires suitable for maximum ambient temperature of 35°C (95°F) for all drivers.

Luminaires are suitable for minimum ambient temperatures of -40ºC (-40ºF) for DIM, DIL, DED, D01, and DL01 drivers. 0ºC (32ºF) for DC2 and DE1 drivers.

Luminaire Finish:

Powder Coat - All Selux luminaries are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accordance with test specifications for coatings from ASTM and PCI.

All products undergo a five stage intensive pretreatment process where product is thor-oughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention.

Standard interior colors are White (WH), Semi-Matte Black (BL), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide.

Warranty:

5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the M100 series LED luminaire shall be free from defects in mate-rial and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed according to Selux instructions and operated within the Ambient Temperature. For additional details and exclusions, see “Selux Terms and Condition of Sale.”

Certifications and Compliance: NRTL - For Dry and Damp location (I.E. cULus)ARRA CompliantRoHS Compliant

4” (101mm)

3 11/16” (94mm)

LW lens shown for reference

3 15/16”” (100mm)

Page 3: M100 Shapes LED Direct [L10] selux · For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details

Page 3 of 10 (Rev. 06/2020)

M100_Shapes_Direct_1C_v1.3

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M100 ShapesLED Direct

Outlet box for feed only (by others)

L10 Cable (C) Suspension Detail (Feed location(s) only)

L10 Cable (C) Suspension Detail (Non-Feed location(s) only)

Cross bar with 1/4”-20 rod and ground screw

1/4” x 5” diameter canopy (White)

2x White cable stay

Cord strain relief bushing

Chrome gripper

1/4”-20 Threaded Rod (supplied and installed in the field by others)

1. Ø1/16” Aircraft Cable with chrome gripper for easy adjustment (48” max. from ceiling to luminaire).

2x Outlet box screws (by others)

1/4”-20 Slip ring coupler

Feed cord (White)

1/16” Aircraft cable

Luminaire

1/4”-20 Slip ring coupler

1/16” Aircraft cable

Chrome gripper

Luminaire

1/4” x 2” diameter Canopy (White)

Cable Mounting (C)

CMOUNTING

POWER FEED

BINSIDE

AOUTSIDE

BINSIDE

AOUTSIDE

CMOUNTING

BINSIDE

AOUTSIDE

POWER FEED HOUSINGBREAK

HOUSINGBREAK

CMOUNTING

BINSIDE

AOUTSIDE

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

POWER FEED

DMOUNTING

EMOUNTING

EMOUNTING

Cable Mounting (C)

*Dimension(s) rounded to the nearest 1/16” with a ± 1/16” (1mm) tolerance.*For rectangle length and width dimensions, reference the square nominal size rows needed.

For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details for standard shapes. These standard shapes are standalone and cannot be combined with any other shapes or lengths. For non-standard sizes, shapes or configurations and patterns please consult factory.

Housing sections and lens lengths:

Note: lens length does not always match housing length. For standard lengths up to 4’, lens will equal side length.

Min. 5/8” toMax. 3/4”

Shape Hexagon Triangle SquareNominal

Leg Length

A Outside B inside C Mounting D Mounting E Mounting A Outside B Inside C Mounting A Outside B Inside C Mounting

Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM

1 1' - 27/16'' 366 0' - 9 7/8'' 250 1' - 9'' 534 1' - 0 1/8'' 308 0' - 61/16'' 154 1' - 7 1/16'' 484 0' - 5 3/8'' 137 1' - 0 3/16'' 310 1' - 4 3/16'' 412 0' - 8 5/16'' 211 1' - 0 1/4'' 311

2 2' - 2 3/8'' 669 1' - 9 13/16'' 553 3' - 5 11/16'' 1059 2' - 0 1/16'' 611 1' - 0 1/16'' 306 2' - 7'' 787 1' - 5 5/16'' 440 2' - 0 3/16'' 614 2' - 4 1/8'' 715 1' - 8 1/4'' 514 2' - 0 3/16'' 615

3 3' - 2 5/16'' 973 2' - 9 3/4'' 857 5' - 2 3/8'' 1584 3' - 0'' 915 1' - 6'' 457 3' - 6 15/16'' 1091 2' - 5 1/4'' 743 3' - 0 1/8'' 917 3' - 4 1/16'' 1018 2' - 8 3/16'' 818 3' - 0 1/8'' 918

4 4' - 2 1/4'' 1276 3' - 9 11/16'' 1160 6' - 11 1/16'' 2109 3' - 11 15/16'' 1218 2' - 0'' 609 4' - 6 7/8'' 1394 3' - 5 3/16'' 1046 4' - 0 1/16'' 1220 4' - 4'' 1322 3' - 8 1/8'' 1121 4' - 0 1/16'' 1221

Page 4: M100 Shapes LED Direct [L10] selux · For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details

Page 4 of 10 (Rev. 06/2020)

M100_Shapes_Direct_1C_v1.3

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M100 ShapesLED Direct

Outlet box (supplied and installed by others)

L1DI Swivel Stem (S) Suspension Detail (feed wires through stem supplied by others)

L1DI Rigid Stem (RS) Suspension Detail (feed wires through stem supplied by others)

Hemispherical assembly

3/8” IP Crossbar with ground screws

1 7/16” x 5” diameter canopy (White)

Cotter pin

3/8” IP steel swivel stem (White)

Luminaire

Luminaire

Outlet box (supplied and installed by others)

3/8” IP nipple (supplied and installed by others)

Suspension hickey

1/4” x 5” diameter Canopy (White)

Canopy securing screwDress nut

Square nut

Square nut

Square nut

Square nut

3/8” IP steel stem (White)

Dress nut

Stem Mounting (S and RS)

1. Ø5/8” Swivel Stem provides 30° swivel and can be cut in field (48” max. from ceiling to luminaire).

2. Ø5/8” Rigid Stem is fixed and is not able to be cut/adjusted in field (48” max. from ceiling to luminaire).

Stem Mounting (S and RS)

CMOUNTING

POWER FEED

BINSIDE

AOUTSIDE

BINSIDE

AOUTSIDE

CMOUNTING

BINSIDE

AOUTSIDE

POWERFEED

HOUSINGBREAK

CMOUNTING

BINSIDE

AOUTSIDE

POWER FEED

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

DMOUNTING

EMOUNTING

EMOUNTING

For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details for standard shapes. These standard shapes are standalone and cannot be combined with any other shapes or lengths. For non-standard sizes, shapes or configurations and patterns please consult factory.

Housing sections and lens lengths:

*Dimension(s) rounded to the nearest 1/16” with a ± 1/16” (1mm) tolerance.*For rectangle length and width dimensions, reference the square nominal size rows needed.

Note: lens length does not always match housing length. For standard lengths up to 4’, lens will equal side length.

Shape Hexagon Triangle SquareNominal

Leg Length

A Outside B inside C Mounting D Mounting E Mounting A Outside B Inside C Mounting A Outside B Inside C Mounting

Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM

1 1' - 27/16'' 366 0' - 9 7/8'' 250 1' - 9'' 534 1' - 0 1/8'' 308 0' - 61/16'' 154 1' - 7 1/16'' 484 0' - 5 3/8'' 137 1' - 0 3/16'' 310 1' - 4 3/16'' 412 0' - 8 5/16'' 211 1' - 0 1/4'' 311

2 2' - 2 3/8'' 669 1' - 9 13/16'' 553 3' - 5 11/16'' 1059 2' - 0 1/16'' 611 1' - 0 1/16'' 306 2' - 7'' 787 1' - 5 5/16'' 440 2' - 0 3/16'' 614 2' - 4 1/8'' 715 1' - 8 1/4'' 514 2' -0 3/16'' 615

3 3' - 2 5/16'' 973 2' - 9 3/4'' 857 5' - 2 3/8'' 1584 3' - 0'' 915 1' - 6'' 457 3' - 6 15/16'' 1091 2' - 5 1/4'' 743 3' - 0 1/8'' 917 3' - 4 1/16'' 1018 2' - 8 3/16'' 818 3' - 0 1/8'' 918

4 4' - 2 1/4'' 1276 3' - 9 11/16'' 1160 6' - 11 1/16'' 2109 3' - 11 15/16'' 1218 2' - 0'' 609 4' - 6 7/8'' 1394 3' - 5 3/16'' 1046 4' - 0 1/16'' 1220 4' - 4'' 1322 3' - 8 1/8'' 1121 4' - 0 1/16'' 1221

Page 5: M100 Shapes LED Direct [L10] selux · For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details

Page 5 of 10 (Rev. 06/2020)

M100_Shapes_Direct_1C_v1.3

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M100 ShapesLED DirectM100LED Direct

Surface Mounting (F)

1. Ø5/16” Mounting hole drilled at the factory (mounting hardware to code by others).

Surface Mount (F)

*Dimension(s) rounded to the nearest 1/16” with a ± 1/16” (1mm) tolerance.*For rectangle length and width dimensions, reference the square nominal size rows needed.

POWER FEED

BINSIDE

AOUTSIDE

BINSIDE

AOUTSIDE

HOUSINGBREAK

HOUSINGBREAK

BINSIDE

AOUTSIDE

POWER FEED

CMOUNTING

POWER FEED

CMOUNTING

CMOUNTING

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

HOUSINGBREAK

CMOUNTING

Shape Hexagon Triangle Square

Nominal Leg Length

A Outside B inside C Mounting A Outside B Inside C Mounting A Outside B Inside C Mounting

Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM

1 1' - 2 7/16'' 366 0' - 9 7/8'' 250 0' - 6'' 152 1' - 7 1/16'' 484 0' - 5 3/8'' 137 0' - 6'' 152 1' - 4 3/16'' 412 0' - 8 5/16'' 211 0' - 6'' 152

2 2' - 2 3/8'' 669 1' - 9 13/16'' 553 1' - 0'' 305 2' - 7'' 787 1' - 5 5/16'' 440 1' - 0'' 305 2' - 4 1/8'' 715 1' - 8 1/4'' 514 1' - 0'' 305

3 3' - 2 5/16'' 973 2' - 9 3/4'' 857 2' - 0'' 610 3' - 6 15/16'' 1091 2' - 5 1/4'' 743 2' - 0'' 610 3' - 4 1/16'' 1018 2' - 8 3/16'' 818 2' - 0'' 610

4 4' - 2 1/4'' 1276 3' - 9 11/16'' 1160 3' - 0'' 914 4' - 6 7/8'' 1394 3' - 5 3/16'' 1046 3' - 0'' 914 4' - 4'' 1322 3' - 8 1/8'' 1121 3' - 0'' 914

For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details for standard shapes. These standard shapes are standalone and cannot be combined with any other shapes or lengths. For non-standard sizes, shapes or configurations and patterns please consult factory.

Note: lens length does not always match housing length. For standard lengths up to 4’, lens will equal side length.

Page 6: M100 Shapes LED Direct [L10] selux · For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details

Page 6 of 10 (Rev. 06/2020)

M100_Shapes_Direct_1C_v1.3

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M100 ShapesLED Direct

Drivers:

Wiring Diagrams

0-10V linear dimming (DIM)Luminaires supplied with drivers offering the capability of either normal switched operation of 0-10V dimming for linear dimming curve. Fixtures ship wired for dimming. For on/off functionality, simply cap the dimming leads. Minimum dimming level preset at factory to 1%. (Due to size constraints, 1’ side length luminaires are supplied with a driver from a different manufacturer than 2’ and above luminaires. For details, please consult factory).

0-10V logarithmic eldoLED ECOdrive dimming (DIL)Luminaires supplied with drivers offering the capability of either normal switched operation of 0-10V dimming for logarithmic dimming curve. Fixtures shipped wired for dimming. For on/off functionality, simply cap the dimming leads. Minimum dimming level preset at factory to 1%.

eldoLED ECOdrive DALI dimming (DED)Luminaires supplied with ECOdrive DALI dimming driver with logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory.

eldoLED SOLOdrive 0-10V linear dimming (D01) Luminaires supplied with SOLOdrive 0-10V dimming driver with linear dimming curve. Minimum dimming level preset at factory to 0.1% and “dim to dark”.

eldoLED SOLOdrive 0-10V logarithmic dimming (DL01) Luminaires supplied with SOLOdrive 0-10V dimming driver with logarithmic dimming curve. Minimum dimming level preset at factory to 0.1% and “dim to dark”.

LUTRON 2-wire dimming (DC2)Luminaires supplied with Hi-Lume 2-wire dimming driver (120V only)programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%.

LUTRON EcoSystem dimming (DE1/DC5)Luminaires supplied with Hi-Lume EcoSystem (4 wire, digital link) dimming driver programmed for Constant Current Reduction (CCR). Minimum dimming level down to 1% (DE1) with SoftOn/FadeToBlack or 5% (DC5).

* For control recommendations, please contact driver manufacturer.

* For driver counts, please see page 7.

- The following wire(s) are in addition to the standard above -

Gray = (-) DALI or 0-10V Dimming ControlPurple = (+) DALI or 0-10V Dimming Control

Violet = “E1” Digital Link Dimming ControlViolet/White = “E2” Digital Link Dimming ControlDE1, DC5

0-10V linear (DIM) 0-10V logarithmic eldoLED Ecodrive (DIL)DALI logarithmic eldoLED ECOdrive (DED)0-10V linear eldoLED SOLOdrive (D01)0-10V logarithmic eldoLED SOLOdrive (DL01)

DIM, DIL, DED D01, DL01

Lutron EcoSystem (DE1)Lutron 5-Series (DC5)

Page 7: M100 Shapes LED Direct [L10] selux · For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details

Page 7 of 10 (Rev. 06/2020)

M100_Shapes_Direct_1C_v1.3

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M100 ShapesLED Direct

Driver Counts for DIM, DIL, DED, D01, DL01 drivers

Driver TypeDIM, DIL, DED,

D01, DL01

Driver Current 1C20 1C25 1C30 1C35 1C40 1C45

Pattern Shape Pattern Size Total Length Driver Quantity

1’ 4’ 1* 1* 1* 1* 2* 2*

2’ 8’ 1 1 2 2 2 2

3’ 12’ 2 2 2 3 3 3

4’ 16’ 2 2 4 4 4 4

1’ 3’ 1* 1* 1* 1* 1* 1*

2’ 6’ 1 1 1 2 2 2

3’ 9’ 2 2 2 3 3 3

4’ 12’ 2 2 2 3 3 3

1’ 6’ 2* 2* 2* 2* 2* 2*

2’ 12’ 2 2 2 3 3 3

3’ 18’ 3 3 3 6 6 6

4’ 24’ 3 3 6 6 6 6

Driver Counts for DE1 driversDriver Type

DE1Driver Current 1C20 1C25 1C30 1C35 1C40 1C45

Pattern Shape Pattern Size Total Length Driver Quantity

1’ 4’ NA NA NA NA NA NA

2’ 8’ 2 2 2 2 2 2

3’ 12’ 2 2 2 3 3 3

4’ 16’ 4 4 4 4 4 4

1’ 3’ NA NA NA NA NA NA

2’ 6’ 1 1 1 3 3 3

3’ 9’ 2 2 3 3 3 3

4’ 12’ 2 2 2 3 3 3

1’ 6’ NA NA NA NA NA NA

2’ 12’ 2 2 2 3 3 3

3’ 18’ 6 6 6 6 6 6

4’ 24’ 6 6 6 6 6 6

Driver Counts for DC2 drivers

Driver TypeDC2

Driver Current 1C20 1C25 1C30 1C35 1C40 1C45

Pattern Shape Pattern Size Total Length Driver Quantity

1’ 4’ NA NA NA NA NA NA

2’ 8’ 2 2 2 2 2 4

3’ 12’ 2 3 3 3 3 4

4’ 16’ 2 4 4 4 4 6

1’ 3’ NA NA NA NA NA NA

2’ 6’ 2 2 2 2 2 2

3’ 9’ 3 3 3 3 3 3

4’ 12’ 2 3 3 3 3 4

1’ 6’ NA NA NA NA NA NA

2’ 12’ 2 3 3 3 3 4

3’ 18’ 3 6 6 6 6 6

4’ 24’ 4 6 6 6 6 8

* DIM drivers only

Page 8: M100 Shapes LED Direct [L10] selux · For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details

Page 8 of 10 (Rev. 06/2020)

M100_Shapes_Direct_1C_v1.3

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M100 ShapesLED Direct

Joiner System - standard for multi-piece housings

Fuse (FS) - Fusing, luminaires supplied with a in-line fuse located on the hot wire for each feed. (supplied with an 8A slow burn fuse).

Damp Location (DL) - Luminaires are suitable for use in damp location(s). Examples of such locations include protected areas under canopies, marquees, roofed porches, and similar locations where the fixture(s) are protected from direct contact with rain, snow, or excessive moisture (such as ocean spray). Interior locations include areas subject to moderate degrees of moisture, such as basements and certain barns and cold storage buildings.

Housing Breaks and Lens Lengths

LENS

LENSLENS

For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. These standard shapes are standalone and cannot be combined with any other shapes or lengths. For non-standard sizes, shapes or configurations and patterns please consult factory.

5/32”

Page 9: M100 Shapes LED Direct [L10] selux · For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details

Page 9 of 10 (Rev. 06/2020)

M100_Shapes_Direct_1C_v1.3

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M100 ShapesLED Direct

Photometry

LW Optics / 35W LED / 3500K CCT

Catalog #: L10-1C35-935-LW-X-04-XX-UReport #: 11685024.03Delivered Lumens: 3218Input Watts: 35.3 Efficacy: 91lm/WCCT: 3500KCRI: 93

MI Optics / 35W LED / 3500K CCT

Catalog #: L10-1C35-935-MI-X-04-XX-UReport #: 11685024.07Delivered Lumens: 3356Input Watts: 35.3Efficacy: 95lm/WCCT: 3500KCRI: 93

Page 10: M100 Shapes LED Direct [L10] selux · For standard shapes and sizes, lens lengths will always be equal to side lengths of the shape. Listed below are the nominal lengths and details

Page 10 of 10 (Rev. 06/2020)

M100_Shapes_Direct_1C_v1.3

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2020, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

M100 ShapesLED DirectM100LED Direct

Photometry

CCT multipliers apply to the photometry, IES files, and per foot values listed on page 1 (light engine).

Light engine and lens multiplier supplied for per foot values listed on page 1 (light engine).

M100 Direct

CCT Multiplier

4000K 1.05

3500K 1.00

3000K 0.96

2700K 0.92

CRI Multiplier

90+ CRI 1.00

80+ CRI 1.19

Lens Multiplier

LW 1.00

MI 1.04

M100 Lumen Table

Pattern Shape Leg Length

Total Length

Light Engine

1C45 1C40 1C35 1C30 1C25 1C20

1’ 4’ 3,776 3,408 3,220 2,572 2,152 1,780

2’ 8’ 7,552 6,816 6,440 5,144 4,304 3,560

3’ 12’ 11,328 10,224 9,660 7,716 6,456 5,340

4’ 16’ 15,104 13,632 12,880 10,288 8,608 7,120

1’ 3’ 2,832 2,556 2,415 1,929 1,614 1,335

2’ 6’ 5,664 5,112 4,830 3,858 3,228 2,670

3’ 9’ 8,496 7,668 7,245 5,787 4,842 4,005

4’ 12’ 11,328 10,224 9,660 7,716 6,456 5,340

1’ 6’ 5,664 5,112 4,830 3,858 3,228 2,670

2’ 12’ 11,328 10,224 9,660 7,716 6,456 5,340

3’ 18’ 16,992 15,336 14,490 11,574 9,684 8,010

4’ 24’ 22,656 20,448 19,320 15,432 12,912 10,680

1X2 6’ 5,664 5,112 4,830 3,858 3,228 2,670

1X3 8’ 7,552 6,816 6,440 5,144 4,304 3,560

1X4 10’ 9,440 8,520 8,050 6,430 5,380 4,450

2X3 10’ 9,440 8,520 8,050 6,430 5,380 4,450

2X4 12’ 11,328 10,224 9,660 7,716 6,456 5,340

3X4 14’ 13,216 11,928 11,270 9,002 7,532 6,230

*Values calculated from a 4’ fixture at 3500K, 90 CRI using LW shielding and a DIM driver.