MCS3020- Research Project
Macular Thickness Diagnosis in 3DEnvironment
UNIVERSITY OF COLOMBO SCHOOL OF COMPUTING
![Page 2: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/2.jpg)
SUPERVISED BY:
Dr. Prasad Wimalaratne
S.W.K.P. Abeysinghe 2009MCS002
STUDENT:
![Page 3: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/3.jpg)
Sections Introduce research domain Aims & Objectives Literature Review Design & Methodology Limitations Future work
![Page 4: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/4.jpg)
OCT (Optical coherence tomography)Captures micrometer-resolution,
three-dimensional images from within optical scattering media (biological tissue)
Usages◦In ophthalmology – Obtained detail
images within the retina.◦In cardiology – Help diagnose
coronary artery disease.
![Page 5: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/5.jpg)
World Health Organization (WHO) (Fact sheet,2013)There are 285 million people are
estimated to be visually impaired in worldwide and about 90% of them live in developing countries.
80% of all visual impairment can be avoided or cured if it identifies as early as possible.
This is possible through OCT reports in ophthalmology.
![Page 6: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/6.jpg)
ProblemNot all medical centers /
hospitals having OCT scanning facility.
Doctor needs to identifies the disease using the printed report.
Manually needs to keep patient report history.
Comparison can be done by checking each reports manually.
![Page 7: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/7.jpg)
AimCreate a platform independent
3D eye diagnosing tool.◦Show the report as a 3D model and
let doctors easily diagnose.◦Let doctors to compare multiple
scans at once within a single view.◦Keep patient’s OCT report history.
![Page 8: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/8.jpg)
ObjectivesIdentify each color thickness in
each OCT machine from the false-color representation in the report.
Model 3D image on the report using the OCT machine color thickness map.
Produce a simple, light weight DBMS to handle and keep scanned data of the patient.
![Page 9: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/9.jpg)
Literature Review On various OCT scan based 3D eye diagnosing
products. On how to examine each OCT machine thickness
based color map. On various data structures to handle functionality of
the color map. On color comparison techniques to identify thickness
from the color map. On various 3D modeling tools. On various DBMS to store data and image/pdf storing
techniques. On various techniques to improve the product external
and internal qualities like correctness, performance, robustness, reusability and maintainability etc.
![Page 10: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/10.jpg)
Sample OCT reportInputs
◦ILM-RPE view◦Color map
![Page 11: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/11.jpg)
Design & MethodologyThickness Map Generation by
Color
![Page 12: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/12.jpg)
Design & Methodology Cont…Thickness color map generator
![Page 13: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/13.jpg)
Design & Methodology Cont…Report thickness identification
using color map◦Need to compare the most suitable
color with the color map◦Use the formula of ;
Low-cost approximation with gamma correction
![Page 14: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/14.jpg)
Design & Methodology Cont…OCT report thickness
identification
![Page 15: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/15.jpg)
Design & Methodology Cont…System architecture
![Page 16: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/16.jpg)
Business layer class diagram
![Page 17: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/17.jpg)
Storage structure
![Page 18: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/18.jpg)
LimitationsLimited number of OCT report
samples available due to the personal information of the patient.
Color scales/ color maps will differ by the OCT machine.
If OCT report was not in a good quality then there might have some thickness identification issues.
![Page 19: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/19.jpg)
Future Work Can be use more advanced image processing
technologies to increase performance of the 3D modelling tool.
Increase security options and advanced features like the report comparison to be handled in parallel with multiple users.
Develop this product to use in mobile devices. With the time of the usage has been increased of the
system, a data mining module can be developed. Report generation and email can also be provided to the
user. All the business components are made generic way,
hence this system also supports to developed to handle other OCT based examinations.
Finally, user interface can also be improved.
![Page 20: Macular Thickness Diagnosis in 3D Environment](https://reader035.vdocument.in/reader035/viewer/2022070517/58cfa89d1a28ab6b088b59c7/html5/thumbnails/20.jpg)
Thank You.