MAG8 Conventional Fire Alarm Panel Main Power Supply......................... ~230 ± 10% Frequency ............................... 50/ 60Hz Back-up Power Supply ...................... 1 battery, 12V/ 7Ah Power availability .......................... 0.7A Main power supply fail consumption............. 125mA Outputs (sounder circuits on the control PCB module) . . . 2; 24V/ 0.5A fuse Output, FAULT Relay ........................ 1; 2A@120VAC; 3A@24VDC Output, FIRE Relay ......................... 1; 2A@120VAC; 3A@24VDC Auxiliary output ........................... 24VDC/ 0.3A fuse Fixed zones .............................. 8 Detectors per zone / max. number of detectors ..... 32/ 256 Multi language front panels ................... YES Operating temperature ...................... 0°C to +40°C Relative humidity resistance .................. (93 ± 3)% @ 40°C Weight (without battery) ..................... ~2.4kg Dimensions of plastic box .................... 340x290x100mm Description Technical and Environmental Specifications Teletek Electronics JSC 14A Srebarna Str, 1407 Sofia, Bulgaria Tel.:+359 2 9694 800 Fax: +359 2 9625 213 [email protected] www.teletek-electronics.com Contact Information: EN54-2/4 MAG8 is a conventional fire alarm panel certificated by EN54-2/4, providing 8 fixed zones. Up to 20 (32 SensoMAG Series) fire detectors can be connected to every fire zone. Unlimited number of call points can be connected to every of the fire zones. MAG8 is situated in a plastic box. The panel is easy for installation and maintenance and provides user-frendly daily operation. The panel is suitable for residential, small and middle office applications with 2 protected area up to 3000m . The panel is available in different language versions for the front panel. 340 290 100 FIRE GENERAL FAULT OUTPUT DELAYED SOUNDER FAULT/DISABLE P FAULT ENABLE / DISABLE TEST POWER SUPPLY 230V

Upload: others

Post on 22-Mar-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MAG8 Conventional Fire Panel Datasheetmedia.bc.pt/multimedia/ARTIGOS_DOCS/MAG 8 - Datasheet.pdfinfo@teletek-electronics.bg Contact Information: EN54-2/4 MAG8 is a conventional fire

MAG8Conventional Fire Alarm Panel

Main Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . ~230 ± 10%Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/ 60HzBack-up Power Supply . . . . . . . . . . . . . . . . . . . . . . 1 battery, 12V/ 7AhPower availability . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7AMain power supply fail consumption. . . . . . . . . . . . . 125mAOutputs (sounder circuits on the control PCB module) . . . 2; 24V/ 0.5A fuse Output, FAULT Relay . . . . . . . . . . . . . . . . . . . . . . . . 1; 2A@120VAC; 3A@24VDCOutput, FIRE Relay . . . . . . . . . . . . . . . . . . . . . . . . . 1; 2A@120VAC; 3A@24VDCAuxiliary output . . . . . . . . . . . . . . . . . . . . . . . . . . . 24VDC/ 0.3A fuseFixed zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Detectors per zone / max. number of detectors . . . . . 32/ 256Multi language front panels. . . . . . . . . . . . . . . . . . . YES Operating temperature . . . . . . . . . . . . . . . . . . . . . . 0°C to +40°CRelative humidity resistance . . . . . . . . . . . . . . . . . . (93 ± 3)% @ 40°CWeight (without battery) . . . . . . . . . . . . . . . . . . . . . ~2.4kgDimensions of plastic box . . . . . . . . . . . . . . . . . . . . 340x290x100mm

Description

Technical and Environmental Specifications

Teletek Electronics JSC14A Srebarna Str, 1407 Sofia, Bulgaria

Tel.:+359 2 9694 800Fax: +359 2 9625 213

[email protected]

Contact Information:

EN54-2/4

MAG8 is a conventional fire alarm panel certificated by EN54-2/4, providing 8 fixed zones. Up to 20 (32 SensoMAG Series) fire detectors can be connected to every fire zone. Unlimited number of call points can be connected to every of the fire zones.MAG8 is situated in a plastic box. The panel is easy for installation and maintenance and provides user-frendly daily operation.The panel is suitable for residential, small and middle office applications with

2protected area up to 3000m .The panel is available in different language versions for the front panel.

340

29

0

100

FIRE

GENERAL FAULT

OUTPUT DELAYED

SOUNDER FAULT/DISABLE

P FAULT

ENABLE / DISABLE

TEST

POWER SUPPLY 230V

Page 2: MAG8 Conventional Fire Panel Datasheetmedia.bc.pt/multimedia/ARTIGOS_DOCS/MAG 8 - Datasheet.pdfinfo@teletek-electronics.bg Contact Information: EN54-2/4 MAG8 is a conventional fire

•English •German •Portugal •Estonian•Italian •Dutch •French •Finnish•Bulgarian •Turkish •Spanish •Hebrew

Available Languages

Packing Information

Teletek Electronics JSC14A Srebarna Str, 1407 Sofia, Bulgaria

Tel.:+359 2 9694 800Fax: +359 2 9625 213

[email protected]

Contact Information:

•Single packing box - 1 unit MAG8 Fire Alarm Panel, dimensions 342x295x103mm•Carton packing box - 5 units MAG8 Fire Alarm Panel, dimensions 560x362x320mm

EN54-2/4MAG8Conventional Fire Alarm Panel

•SensoMAG Series - Conventional detectors•SF105, SF110, SF200, SF300 - Conventional sounders•ML - LOG module for recording and viewing event•MR8 - 8 relay expander module

Compatible Product Range