8
MagFlo Series Product Manual TM Important Information........................ 2 Package Contents............................. 3 Installing Your MagFlo Pump................. 4-5 Maintaining Your MagFlo Pump .............. 6-7 Troubleshooting .............................. 7 Technical Specs ............................... 8 Replacement Parts ........................... 8 Warranty Information......................... 8 Table of Contents: For Models: • MagFlo 290 (Item #120930) • MagFlo 460 (Item #120932) • MagFlo 590 (Item #120933) • MagFlo 1000 (Item #120935) • MagFlo 1340 (Item #120936) • MagFlo 2160 (Item# 120938)

Upload: others

Post on 22-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MagFlo Series - Amazon S3...failure to follow safety precautions, misuse or abuse of equipment. Power Cord Drip Loop 2 thepondguy.com 866-POND-HELP (766-3435) Package Contents MAGFLO

MagFlo™ Series Product Manual

TM

Important Information. . . . . . . . . . . . . . . . . . . . . . . . 2Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Installing Your MagFlo Pump. . . . . . . . . . . . . . . . . 4-5Maintaining Your MagFlo Pump . . . . . . . . . . . . . . 6-7 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Technical Specs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Warranty Information. . . . . . . . . . . . . . . . . . . . . . . . . 8

Table of Contents:

For Models:

THANK YOU FOR CHOOSING:

• MagFlo 290 (Item #120930)

• MagFlo 460 (Item #120932)

• MagFlo 590 (Item #120933)

• MagFlo 1000 (Item #120935)

• MagFlo 1340 (Item #120936)

• MagFlo 2160 (Item# 120938)

Page 2: MagFlo Series - Amazon S3...failure to follow safety precautions, misuse or abuse of equipment. Power Cord Drip Loop 2 thepondguy.com 866-POND-HELP (766-3435) Package Contents MAGFLO

IMPORTANT INFORMATION:Please read these instructions thoroughly before use. Failure to follow instructions may result in equipment damage or failure, losses, injury or death.

DANGER: To avoid possible electric shock:

• If the power cord has been damaged, DO NOT operate, the MagFlo Pump should be replaced.

• Close supervision is necessary when the unit is used by or near children.

WARNING: To reduce the risk of electric shock:

• Connect only to a properly grounded receptacle, which is serviced by a Ground Fault Circuit Interrupter and never remove the ground pin from the plug.

• Provide a “drip loop” for the power cord. This is a loop in the cord below the level of the receptacle or plug that prevents water from traveling along the cord in the direction of the receptacle.

• ALWAYS unplug the MagFlo Pump from power source when it is not in use, and before installing, removing or servicing the MagFlo Pump components.

• If an extension cord is necessary, a cord 14 gauge up to 100 ft. must be used. A cord may overheat if the cord is rated for less amperes or watts than the unit rating.

• DO NOT immerse the MagFlo Pump plug in water or attempt to use a wet plug.

• The MagFlo Pump is NOT suitable for use in swimming pools, swimming ponds, or other situations where bodily contact is made with the water.

Important – This unit is equipped with a permanent magnet. The magnetic field may affect the function of pacemakers.

CAUTION: To reduce the risk of equipment damage or failure:

• This pump has been evaluated for use with fresh water only.

• DO NOT place MagFlo Pump near flammable or other dangerous materials or objects.

• ALWAYS unplug the unit if there is no water running through it to prevent over heating.

• DO NOT run the pump dry.

• DO NOT operate during freezing conditions. Drain MagFlo Pump and store in a protected location.

IMPORTANT: The Pond Guy is not responsible for equipment damage or failure, losses, injury or death resulting from failure to follow safety precautions, misuse or abuse of equipment.

Power Cord

Drip Loop

thepondguy.com | 866-POND-HELP (766-3435) 2

Page 3: MagFlo Series - Amazon S3...failure to follow safety precautions, misuse or abuse of equipment. Power Cord Drip Loop 2 thepondguy.com 866-POND-HELP (766-3435) Package Contents MAGFLO

Package Contents MAGFLO PUMP:

A

B

*MagFlo 1340 shown here. All MagFlo units include suction cup feet with exception to the Magflo 290. **Venturi Adapter can be used to add small amounts of aeration to into pump line

C FED

M

L

K

MagFlo Pump

A 1 - MagFlo Pump H 1 - Venturi Adapter**

B 4 - Suction Cup Feet* I 1 - Inlet Male Tubing Adapter

C 1 - Diverter Assembly J 2 - Outlet Male Tubing Adapters

D 1 - Fountain Extension Tube K 1 - Volcano Spray Pattern

E 1 - Coupler L 1 - Water Bell Spray Pattern

F 1 - Pivot Attachment M 1 - Double Volcano Spray Pattern

G 2 - Female Tubing Adaptors

H

G

CLEANING THE PUMP

I J

Please Note: Kits may vary depending on pump purchased.

15425 Chets Way | Armada, MI 48005 3

Page 4: MagFlo Series - Amazon S3...failure to follow safety precautions, misuse or abuse of equipment. Power Cord Drip Loop 2 thepondguy.com 866-POND-HELP (766-3435) Package Contents MAGFLO

For Best Results

INSTALLING YOUR MAGFLO PUMP:

Step 1Determine Installation MethodThe MagFlo’s versatile nature allows you to configure your pump set up in multiple ways. Select the method below that best suits your use.

Fountain Only1. Connect fittings to the pump outlet in this

order; diverter assembly (C), pivot attachment (F), coupler (E), fountain extension tube (D).

2. Select the fountain spray pattern (K, L, M) you will be using and press on to the extension tube (D).

3. Continue with step 2.

Fountain & Waterfall/Feature1. Complete set up for “fountain only” first.2. Unscrew the diverter cap on the diverter (C) and

attach one of the female tubing adaptors (G).3. Connect and secure tubing to the diverter (C)

and your waterfall/feature.4. Continue with step 2.

• MagFlo Pump should be placed on a flat surface away from sludge or algae mats.

• Keep MagFlo Pump pre-filter free of debris.

• DO NOT operate during freezing conditions. Drain the MagFlo Pump and store in a protected area.

Note: All MagFlo units can function as both a waterfall or fountain simultaneously with exception to the Magflo 290.

thepondguy.com | 866-POND-HELP (766-3435) 4

Page 5: MagFlo Series - Amazon S3...failure to follow safety precautions, misuse or abuse of equipment. Power Cord Drip Loop 2 thepondguy.com 866-POND-HELP (766-3435) Package Contents MAGFLO

INSTALLING YOUR MAGFLO PUMP:

Step 3Plug in PumpPlug the power cord into a standard 120-volt GFCI protected outlet.

Step 4Adjust Water FlowAdjust water flow using the diverter valve flow control, if applicable, for your installation. For the Water Bell fountain pattern, it may also be necessary to unscrew or tighten the deflector disc on the top of the nozzle for proper flow.

Step 5Adjust Fountain SprayTo compensate for uneven surfaces, adjust the fountain spray direction by tilting the fountain assembly gently at the pivot attachment (F)

Step 2Submerge PumpSubmerge the MagFlo Pump in a flat area in your pond. For ideal water circulation, the pump should be at the opposite end of the pond from where the water will discharge. If the fountain feature will be used, be sure the nozzle is at least a few inches above the water’s surface.

Waterfall/Feature Only1. Connect one of the male adaptors to the

pump outlet.2. Connect and secure tubing to the pump and

waterfall/feature.3. Continue with step 2.

Note: You may also choose to use a separate pre-filter inline by removing the pump intake screen and connecting the Inlet Male Tubing Adaptor (I). This pump can also be used in-line, out of the water for the waterfall/feature only option but it must still be placed below water level. This pump has a flooded suction intake and will not suction lift.

15425 Chets Way | Armada, MI 48005 5

Page 6: MagFlo Series - Amazon S3...failure to follow safety precautions, misuse or abuse of equipment. Power Cord Drip Loop 2 thepondguy.com 866-POND-HELP (766-3435) Package Contents MAGFLO

WARNING: Before performing any maintenance, always unplug the MagFlo Pump from the power source.

Perform maintenance anytime there is a reduction in water flow or before being stored for the winter.

MAINTAINING YOUR MAGFLO PUMP:

Step 1Unplug and RemoveUnplug the pump and move to a dry area.

Step 2Remove Pre-FilterPull firmly to remove the pump pre-filter from the pump motor.

Step 3Wash Pre-Filter SpongeRemove pump pre-filter sponge and wash thoroughly with water.

CLEANING THE PUMPTools Required: • Damp Cloth or Small Brush

• Descaler such as Airmax© D-Scale™

thepondguy.com | 866-POND-HELP (766-3435) 6

Page 7: MagFlo Series - Amazon S3...failure to follow safety precautions, misuse or abuse of equipment. Power Cord Drip Loop 2 thepondguy.com 866-POND-HELP (766-3435) Package Contents MAGFLO

TROUBLESHOOTING:Pump does not turn on:• Check that the power cord is connected. • Check to see if the circuit breaker is tripped. • GFCI may be faulty. • Check power cord for damage.Pump turns on and then shuts off:• Verify pump is completely submerged for proper cooling.• Check for debris clogging the pump intake.• If using an extension cord, verify that it is of the proper rating for the pump’s electrical requirements. Reduced water flow:• Check for debris clogging the pump pre-filter. • Perform maintenance cleaning of the pump.• Verify that water level is not low.• Check plumbing for clogs.

MAINTAINING YOUR MAGFLO PUMP:

Step 4Remove Impeller CoverRemove the impeller cover by turning counter-clockwise and then pull to separate. Remove the Impeller.

Step 5Clean ImpellerClean impeller and impeller chamber with water. A small brush or descaler may be helpful.

Step 6Reassemble PumpReassemble impeller, impeller cover and pump pre-filter.

Please note: Lower the impeller carefully into the chamber. Allowing the impeller to drop into the chamber with too much force can damage the pump.

15425 Chets Way | Armada, MI 48005 7

Page 8: MagFlo Series - Amazon S3...failure to follow safety precautions, misuse or abuse of equipment. Power Cord Drip Loop 2 thepondguy.com 866-POND-HELP (766-3435) Package Contents MAGFLO

View other great products on-line at www.thepondguy.com

PRODUCT WARRANTY:MagFlo Pumps carry a 5-year warranty. The Pond Guy will repair or replace any unit found to be defective. This limited warranty is extended exclusively to the original purchaser and begins from the date of original purchase receipt. Abuse or misuse of this product or power cord alterations void all warranty. Impeller and filter sponge are wear items and are not covered by this warranty. Please call for a RMA number prior to returning product by calling our Customer Care Department at 866-766-3435. Failure to request an RMA number may result in delay or dismissal of your warranty claim.

THANK YOU FOR CHOOSING:The Pond Guy® Inc.We Know Ponds™

15425 Chets WayArmada, MI 48005

866-POND-HELP (766-3435)thepondguy.com

REPLACEMENT PARTS: MAGFLO PUMP

013_RES V2

MAGFLOPUMP MODEL

REPLACEMENT IMPELLER

REPLACEMENTFILTER SPONGE REPLACEMENT FOUNTAIN KIT

MagFlo 290 #120939 #120948 #120956

MagFlo 460 #120941 #120950 #120958

MagFlo 590 #120942 #120950 #120958

MagFlo 1000 #120944 #120952 #120960

MagFlo 1340 #120945 #120953 #120960

MagFlo 2160 #120947 #120955 #120963

TECHNICAL SPECS:MODEL VOLTAGE WATTAGE CORD GPH @ 3’ HEAD MAX HEAD DISCHARGE INLET FITTING

MagFlo 290 120V / 60 Hz 17 Watts 20’ 197 GPH 6.5’ ½” 1” ½” & ¾”

MagFlo 460 120V / 60 Hz 45 Watts 20’ 260 GPH 7’ ½” 1” ½” & ¾”

MagFlo 590 120V / 60 Hz 40 Watts 20’ 420 GPH 7.5’ ½” 1” ½” & ¾”

MagFlo 1000 120V / 60 Hz 70 Watts 20’ 760 GPH 9’ ½” 1” ¾”

MagFlo 1340 120V / 60 Hz 125 Watts 20’ 1250 GPH 13.5’ ¾” 1¼” ¾” & 1”

MagFlo 2160 120V / 60 Hz 226 Watts 20’ 1790 GPH 16.5” 1” 1¼” ¾”, 1” & 1¼”