maglisto 5m plasmid extraction kit - bioneer · i. overview 1 ii. kit components 1 iii. storage 2...
TRANSCRIPT
K-3600 K-3601
.
User’s Guide
MagListo™ 5M Plasmid Extraction Kit
MagListo™ 5M Plasmid Extraction Kit
MagListo™ 5M Plasmid Extraction Kit
Kit for the extraction of plasmid from bacterial cultures using MagListo™
User’s Guide
K-3600 K-3601
Version No.: 2.0 (2017-03)
Please read all the information in booklet before using the unit
Bioneer Corporation
8-11, Munpyeongseo-ro, Daedeok-gu, Daejeon
34302, Republic of Korea
Tel: +82-42-930-8777
Fax: +82-42-930-8688
Email: [email protected]
www.bioneer.com
MagListo™ is a trademark of Bioneer Corporation.
Copyright 2017. Bioneer Corporation. All Rights Reserved.
MagListo™ 5M Plasmid Extraction Kit
Contents
I. Overview 1
II. Kit Components 1
III. Storage 2
IV. Intended Use 2
V. Safety Warnings and Precautions 2
VI. Warranty and Liability 3
VII. Technical Assistance 3
VIII. Quality Management 3
IX. Kit Specifications 4
X. Sample Preparation 4
XI. Principle 6
XII. Magnetic Nano Bead Information 6
XIII. Guidelines for MagListo™ Magnetic Separation Rack 7
XIV. Materials and Equipment Needed But Not Provided 8
Types of the Magnetic Separation Rack 8
XV. Procedure 9
XVI. Protocols 10
Before You Begin 10
Bacteria Culture and Collection 10
Plasmid Extraction Protocol for Mini/Midi/Maxi/8 channel 11
Summary of Reagents Volume in Each Step 14
MagListo™ 5M Plasmid Extraction Kit
XVII. Appendix 15
Troubleshooting guide 15
Experimental data 18
XVIII. Ordering Information 20
XIX. Explanation of Symbols 21
4
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
I. Overview
Description
MagListo™ 5M Plasmid Extraction Kit utilizes Magnetic Nano Beads to extract plasmid DNA rapidly from
bacterial cultures with the aid of the MagListo™ Magnetic Separation Rack. The use of MagListo™
Magnetic Separation Rack along with the kit greatly increases user convenience by shortening the
extraction time without centrifugation.
Features and Benefits
- Magnetic Nano Beads enable the rapid nucleic acid extraction
- No requirement of expensive instruments
- A single kit serves mini or midi scale experiment
Applications
Gene Cloning, PCR, Sequencing, Transformation, Transfection, In-vitro Transcription/Translation
II. Kit Components
MagListo™ 5M Plasmid Extraction Kit *K-3601 **K-3600
Buffer ① (Resuspension) 25 ml x 1 ea 110 ml x 1 ea
Buffer ② (Lysis) 25 ml x 1 ea 110 ml x 1 ea
Buffer ③ (Neutralization) 25 ml x 1 ea 110 ml x 1 ea
Buffer ④ (Binding) 75 ml x 1 ea 180 ml x 2 ea
Buffer ⑤ (3rd Washing) 120 ml x 1 ea 250 ml x 2 ea
Buffer ⑥ (Elution) 15 ml x 1 ea 50 ml x 1 ea
Magnetic Nano Bead 1.2 ml x 5 ea 30 ml x 1 ea
RNase A powder, lyophilized 3 mg x 1 ea 12 mg x 1 ea
*mini – 100 rxn, midi – 10 rxn, maxi – 4 rxn **mini – 500 rxn, midi – 50 rxn, maxi – 18 rxn
5
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
III. Storage
MagListo™ 5M Plasmid Extraction Kit should be stored at room temperature. It can be stored for up to 2
years if it remains sealed. Buffers may form precipitates during storage. If this occurs, please warm the
buffer to 37℃ until the precipitates are completely dissolved. After addition of RNase A powder, Buffer ①
(Resuspension) is stable for 6 months when stored at 2-8℃. RNase A powder can be stored for two years
at room temperature. A white precipitate may form in Buffer ② (Lysis) or Buffer ④ (Binding) after
prolonged storage at low temperature. Incubating at 60℃ should dissolve any precipitate in Buffer ②
(Lysis) or Buffer ④ (Binding).
IV. Intended Use
MagListo™ 5M Plasmid Extraction Kit is intended for research use only. This kit is not intended for human
or veterinary diagnostics.
V. Safety Warnings and Precautions
Please inquire BIONEER’s Customer Service Center to obtain a copy of the Material Safety Data Sheet
(MSDS) for this product.
Before, during and after using this kit, all potentially hazardous materials (i.e. materials that may have
come in contacted with genetically recombinant samples) including tubes, tips and other kit contents
should be processed and discarded in accordance with applicable and appropriate regulations of the
municipality/government in which this product is being used. A user must also be equipped with basic
experimental techniques required for correct execution of the extraction experiments described in this
User’s Guide.
Some inventions applied in this kit may infringe existing patents in certain countries. The purchase of this
kit does not include or provide a license to perform such patented inventions. Users may be required to
obtain a license depending on the patent law of the country where this product is being used. We do not
condone nor recommend the unlicensed use of patented inventions.
6
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
VI. Warranty and Liability
All BIONEER products are manufactured and tested under strict quality control protocols. BIONEER
guarantees the quality of all directly manufactured products during the warranty period of one (1) year from
the date of purchase. If any issues are discovered relating to compromise in product quality, immediately
contact BIONEER’s Customer Service Center ([email protected]).
BIONEER does not assume any liability for the misuse of the product, i.e. usage of the product for any
purposes other than its intended purpose as described in the User’s Guide. BIONEER assumes liability
under the condition that users disclose all information related to the problem to BIONEER in written form
within 30 days of occurrence.
VII. Technical Assistance
At Bioneer, we pride ourselves on being responsive to your needs. Our Technical Service Departments are
staffed by experienced scientists with extensive practical and theoretical expertise in Molecular Biology and
the use of Bioneer products. If you have any questions or would like to find out more information about
MagListo™ products, please contact us. We look forward to hearing from you!
Technical Support
For all technical questions and troubleshooting on Bioneer products and applications.
Tel: +82-42-930-8777
Email: [email protected]
In North America
Tel: +1-877-264-4300
Email:[email protected]
VIII. Quality Management
Every aspect of our quality management system from product development, production to quality
assurance and supplier qualification meets the world-class standards. Each lot of MagListo™ 5M Plasmid
Extraction Kit is carefully tested by the quality control team.
7
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
IX. Kit Specifications
Scale Micro scale Mini scale Midi scale Maxi scale
Starting culture volume 1 - 1.5 ml 1 - 5 ml 20 - 50 ml 100 - 200 ml
Preparation time < 20 min < 5 min < 10 min < 15 min
Elution volume 100 µl 100 µl 500 µl 1 ml
Expected DNA yield Up to 10 µg Up to 20 µg Up to 200 µg Up to 500 µg
Expected purity A260/280 > 1.8
* The yield of low copy plasmid could be less than the amount shown in this table.
X. Sample Preparation
Starting material
Several factors such as plasmid copy number, bacterial strain, antibiotics, inoculation and type of culture
medium may influence the yield of plasmid DNA. It is recommended to extract plasmids from the bacterial
cultures that have been inoculated with a single pure colony from the agar plate.
Copy number of plasmid
Plasmids used in molecular cloning usually contain pMB1 derived replicons (e.g. pUC plasmid). Plasmids
that contain pMB1 derived replicons have a relaxed control of replication and thus have very high copy
numbers. In contrast, pSC101 plasmid has a stringent control of replication and maintain a low copy
number. Generally, high-copy number plasmids will result in higher yield than low-copy number plasmids.
Table 1. Replicons carried by various plasmid vectors
Plasmids Copy number Replicon Classification
pUC 500-700 pMB1* High copy
pGEM 300-500 pMB1* High copy
pBluescript 300-500 ColE1* High copy
pTZ >1000 pMB1* High copy
pET 15-20 pMB1* Low copy
8
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
pAYC 10-12 P15A Low copy
pBR322 15-20 pMB1* Low copy
pSC101 ~5 pSC101 Very low copy
* The pMB1 origin of replication (ori) is closely related to that of ColE1 and belongs in the same incompatibility group
of ColE1. The high-copy plasmids listed above contain pMB1 derived replicons.
Host strains
Some strains, especially endA+ strains such as JM101, JM110, HB101, TG1 and their derivatives may
produce lower yield and quality of plasmid DNA than DH1, DH5α and XL1-Blue strains. In addition, strains
derived from HB101 strains can produce large amounts of carbohydrates, which may inhibit activity of many
restriction enzymes and polymerases.
Antibiotics
Antibiotics used in bacterial selection can influence growth of bacteria at all stages. As antibiotics are
sensitive to storage condition and high temperatures, stock solutions of antibiotics should be stored in
aliquots at -20℃. To test whether antibiotics are still effective, fresh cultures inoculated from freshly prepared
bacterial culture plates should be used.
Table 2. Recommended concentrations of commonly used antibiotics
Antibiotics Stock solution Storage Working concentration
Ampicillin 40mg/ml in H2O -20℃ 80μg/ml
Tetracycline HCl 10mg/ml in 50% Ethanol -20℃ 50μg/ml
Kanamycin 10mg/ml in H2O -20℃ 50μg/ml
Culture medium
The Luria Bertani (LB) medium is one of the most commonly used media to grow bacterial cells. MagListo™
5M Plasmid Extraction Kit is optimized for use with LB media. As the ratio of plasmid DNA to RNA is higher
during the logarithmic phase, it is recommended to collect bacterial cells cultured for approximately 12 h to
16 h (when stationary growth phase starts).
9
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
XI. Principle
MagListo™ 5M Plasmid Extraction Kit is designed for the extraction of highly purified plasmid from
cultured bacterial cells as fast as 5 min. The overall principle is based on the modified alkaline lysis
method (Birnboim et al, 1979) and Bioneer’s novel Nano-Technology (Patent pending).
Collected cells are re-suspended in Buffer ① (Resuspension) that contains Nano Beads, followed by a
lysis step with the addition of Buffer ② (Lysis). When Buffer ③ (Neutralization) is added to the lysate, the
chromosomal DNA and cell debris forms insoluble aggregates. While forming aggregates, Bioneer’s Nano
Beads effectively facilitate the process by binding to protein and cell debris aggregates and increasing the
total weight of the complex. The aggregates are separated using a magnetic force from supernatant
including plasmid, which is then transferred to a new tube for an ensuing process. Guanidine hydrochloride,
as chaotropic agents in Buffer ④ (Binding), removes water molecules around DNA and silica coated
magnetic bead surface resulting in plasmid then being captured by silica coated magnetic beads. The
magnetic bead and nucleic acid complexes are pulled and fixed on the tube wall using a magnetic force,
followed by washing with 80% ethanol to remove debris and excessive salts. The captured nucleic acids
are then eluted by Buffer ⑥ (Elution), an aqueous solution with optimal pH.
Sample Lysis Binding Washing Elution
XII. Magnetic Nano Bead Information
Description
Magnetic Nano Beads have been developed to overcome shortcomings of existing resin and to automate
purification process. The principle of extraction using the Magnetic Nano Beads is that coated functional
group on the surface of the Magnetic Nano Beads bind with DNA and the Magnetic Nano Beads are then
isolated using external magnetic field.
10
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
Features
⚫ Fast binding guarantees higher throughput automation
⚫ Large Surface Area enables more sensitive assay
⚫ Globular structure increases specificity by decreasing non-specific binding
Specification
AccuNanoBead™ Silica Magnetic Nano Beads
Matrix Silica-coated Fe3O4
Average size 400nm
Ligand -OH
Working Temp. 0-100℃
Storage Store at room temperature upon receipt
XIII. Guidelines for MagListo™ Magnetic Separation Rack
Description
MagListo™ Magnetic Separation Rack is designed for a fast, easy separation of the Magnetic
NanoBeads. These racks of different sizes allow users to choose the product according to their needs.
The following are recommended when handling the MagListo™ Magnetic Separation Rack
⚫ The product is made of acryl and plastic. Be careful not to drop the product as the dropping may
break the product.
⚫ When moving the product, take extra care not to drop the product as it may cause injury.
⚫ If the product is broken, do not discard it with bare hands as the sharp edges may cause injury.
⚫ When an extracted or purified nucleic acid is spilled on the product, immediately rinse it with running
water and clean it with 70% ethanol.
⚫ Acetone, Toluene, or organic solvent may damage the acrylic and plastic part of the product, which
may lead to malfunction of the product. Rinse the product immediately when spillage of any above
mentioned solvents occurs as the expected DNA yield may not be obtained if the product is
damaged.
⚫ Make sure that a corrosive liquid on the magnet plate part of the product. If spillage occurs,
immediately rinse it off with running water as it may corrode the magnet during storage and may
11
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
degrade its performance.
XIV. Materials and Equipment Needed But Not Provided
1. Centrifuge with rotor capable of 3,000 x g (midi & maxi scale)
2. 2 ml tube (mini scale), 15 ml tube (midi scale), 50 ml tube, (maxi scale), 1 ml tube (8-channel prep)
3. 96-well plate
4. Vortex mixer
5. 80% ethanol
6. MagListo™ Magnetic Separation Rack
7. (Optional) Table-top microcentrifuge, 16,000 x g (>13,000 rpm) (mini scale), High speed centrifuge
(capable of ≥12,000 rpm, e.g., Beckman Avanti® J Series, Sorvall® RC-5B Plus, Hanil Supra series)
(midi, maxi scale)
Types of the Magnetic Separation Rack
Tube MagListo™ Magnetic Separation Rack
1 ml tube with 8-cap strip MagListo™-8Ch Magnetic Separation Rack
(Cat. no. TM-1000)
1.5 ml or 2 ml microcentrifuge tube MagListo™-2 Magnetic Separation Rack
(Cat. no. TM-1010)
15 ml tube MagListo™-15 Magnetic Separation Rack
(Cat. no. TM-1020)
50 ml tube MagListo™-50 Magnetic Separation Rack
(Cat. no. TM-1030)
(Note) Please refer to the ordering information in this User’s Guide for more information
regarding catalog number of racks designed for specific size of tubes.
12
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
XV. Procedure-Plasmid Extraction
13
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
XVI. Protocols
Before You Begin
1. Completely dissolve RNase A powder in Buffer ① (Resuspension). After addition of RNase A powder,
Buffer ① (Resuspension) is stable for 6 months when stored at 2 - 8℃.
2. Buffer ④ (Binding) contains chaotropic salt. You should take the appropriate laboratory safety
precautions and wear gloves when handling.
3. The relative centrifugal force (RCF) is calculated in g as follows:
RCF = 1.12 x r x (rpm/1,000)2
Where ‘r’ is the radius of a rotor in cm, and ‘rpm’ is the speed of the rotor in revolutions per minute.
4. If there is any precipitate in Buffer ② (Lysis), incubate on a heating block at 56℃
Bacterial Culture and Collection
⚫ For mini prep / 8-channel prep
1. Pick up a single pure colony from freshly cultured LB (Luria-Bertani) agar plate or your media of choice
containing antibiotics, and inoculate into 1 ml to 5 ml of fresh LB liquid media or your liquid media in a
shaking incubator at 37℃ for 12 h to16 h.
(Note) The overgrowth of E. coli cells may cause cell death, which may lead to lower yield of plasmid
DNA due to inefficient lysis.
For high copy number plasmid: 1 - 5 ml of E. coli cells.
For low copy number plasmid: 2 - 10 ml of E. coli cells.
2. After incubation, collect the E. coli cells by centrifuging at 6000 x g for 15 min at 4℃. Remove the
supernatant (liquid media) completely using a paper towel by blotting action.
3. Continue with “Plasmid Extraction Protocol” in page 10 for extraction of plasmids.
⚫ For midi prep / maxi prep
1. Pick up a single pure colony from freshly cultured LB (Luria-Bertani) agar plate or your media of
choice containing antibiotics, and inoculate into 1 ml to 5 ml of fresh LB liquid media in a shaking
incubator at 37℃ for 12 h to 16 h.
2. After incubation, re-inoculate 50 μl of cultured liquid media into 20 - 50 ml (midi) / 100 - 200 ml (maxi)
of fresh LB liquid media or your liquid media of choice containing antibiotics. Incubate the inoculated
liquid media in a shaking incubator at 37℃ for 12 h to 16 h.
3. After incubation, collect the E. coli cells by centrifuging at 6 000 x g for 15 min at 4℃. Remove the
supernatant (liquid media) completely using a paper towel by blotting action.
4. Continue with “Plasmid Extraction Protocol” in page 10 for extraction of plasmids.
14
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
Plasmid Extraction Protocol for Mini / Midi / Maxi / 8-channel
1. (Resuspension of E. coli pellet) Add 200 μl (mini) / 2 ml (midi) / 6 ml (maxi)/ 100 μl (8-channel) of
Buffer ① (Resuspension) to the harvested cell pellet and completely resuspend by vigorous vortexing
or several pipetting.
(Note) You must completely resuspend the cell pellet to achieve maximum lysis efficiency. Given that
buffer ① (Resuspension) contains Magnetic Nano Beads, please shake well the bottle before
use. If you have harvested cell pellet in a 15 ml (mini) / 50 ml (midi) / 100-250 ml (maxi) / 1.5
ml (8-channel) tube, please transfer the resuspended cells to a 2 ml or 1.5 ml (mini) / 15 ml
(midi) / 50 ml (maxi) / 1 ml (8-channel) tube.
*Caution! Please check the magnetic bead completed suspended in solution. Incomplete suspension
can lead to partial removal of aggregation.
2. (Lysis of cell) Add 200 μl (mini) / 2 ml (midi) / 6 ml (maxi) / 100 μl (8-channel) of Buffer ② (Lysis) to
the each tube and mix by inverting the tube 3-4 times gently.
(Note) Do not vortex but just invert gently. Vortexing can cause shearing of genomic DNA.
3. (Neutralization) Add 200 μl (mini) / 2 ml (midi) / 6 ml (maxi) / 100 μl (8-channel) of Buffer ③
(Neutralization) to the each tube and immediately mix by inverting the tube 3-4 times gently.
(Note) Genomic DNA and cell debris will form an insoluble complex with Nano Beads in this step.
Again, be cautious to handle the lysate gently not to shear genomic DNA.
4. (Debris removal: 4-6) Place the tube on the MagListo™-2 (mini) / -15 (midi) / -50 (maxi) /-8Ch (8-
channel) rack Magnetic Separation Rack with the magnet plate attached and invert the rack gently 3-4
times until the beads bind tightly to magnet.
(Optional) For better yield, centrifuge the tube at 13,000 rpm for 1 min (mini) / 5 min (midi) / 10 min
(maxi). Transfer cleared lysate to a new 2 ml or 1.5 ml (mini) / 15 ml (midi) / 50 ml (maxi)
tube and go step 7.
- Attachment of the magnet plate
Combine the magnet plate to the stand.
15
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
5. Without removing the tube from MagListo™ Magnetic Separation Rack, transfer the supernatant
carefully to a new 2 ml (or 1.5 ml) (mini) / 15 ml (midi) / 50 ml (maxi) / 1 ml (8-channel) tube.
6. Repeat the above step 4 and 5 for clearer supernatant. We strongly recommend the repetition for
better results.
7. (Plasmid binding with Magnetic Nano Bead: 7-9) Add 600 μl (mini) / 6 ml (midi) / 18 ml (maxi) / 300 μl
(8-channel) of Buffer ④ (Biding) and then add 50 μl (mini)/ 300 μl (midi)/ 1.5 ml (maxi)/ 25 μl (8-
channel) of evenly mixed Magnetic Nano Bead solution to the each tube. Close the cap and mix by
inverting the each tube 3-4 times with the magnet plate detached.
(Note) Magnetic Nano Bead solution contains Magnetic Nano Beads. Please shake well before use.
8. Place the tube on the MagListo™ Magnetic Separation Rack with the magnet plate attached and invert
the rack gently 3-4 times until the beads bind tightly to magnet.
9. Without removing the each tube from MagListo™ Magnetic Separation Rack, discard the supernatant
carefully completely remove the remaining supernatant on a paper towel by using blotting action.
During this process, the magnetic crude pellet remains attached to the side of tube.
- How to discard the supernatant
Discard the supernatant by inverting the MagListo™ Magnetic Separation Rack. The silicone
immobilizer inside the stand prevents the tubes from falling. When discarding the supernatant, invert
the rack completely so that the solution does not to spill on the rack.
10. (Washing: 10-12) Detach the magnet plate from MagListo™ Magnetic Separation Rack. Add 1 ml
(mini) / 10 ml (midi) / 30 ml (maxi) / 500 μl (8-channel) of 80% ethanol to the tube and close the cap.
Mix by inverting until the beads are fully resuspended.
- Detachment of the magnet plate
16
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
Detach the magnet plate gently by pulling it upwards.
11. Attach the magnet plate and invert the rack gently 3 to 4 times until the beads bind tightly to the
magnet.
12. Without removing the tube from MagListo™ Magnetic Separation Rack, discard the supernatant and
completely remove the remaining supernatant on a paper towel by blotting action.
13. Repeat the above step 10-12 by adding 1 ml (mini) / 10 ml (midi) / 30 ml (maxi) / 500 μl (8-channel)
of 80% ethanol for additional washing.
14. (3rd Washing) Without removing the tubes from the MagListo™ Magnetic Separation Rack, add 700 μl
(mini, 8-channel) / 10 ml (midi) / 25 ml (maxi) of Buffer ⑤ (3rd Washing) to “the opposite side of bead
pellet”. Close the cap and invert the rack twice in order to remove ethanol from the sample.
(Note) Direct pipetting of Buffer ⑤ onto the bead pellet, vortexing and/or vigorous shaking of the
tubes may release nucleic acid from the beads, which results in lower DNA yield.
15. Discard the supernatant and completely remove the remaining supernatant by blotting action.
- Add Buffer ⑤ and discard the supernatant
16. (Elution: 16-20) Detach the magnet plate from the MagListo™ Magnetic Separation Rack. Add 100 μl
(mini, 8-channel) / 500 μl (midi) / 1 ml (maxi) of Buffer ⑥ (Elution) or distilled water to the each tube
with the magnet plate detached and resuspend by tapping the tube wall.
17
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
17. Incubate the tubes at 60℃ for 1 min.
18. Place the tubes on the MagListo™ Magnetic Separation Rack. Attach the magnet plate and invert the
rack gently 3 to 4 times until the beads bind tightly to the magnet.
19. Without removing the tube from the MagListo™ Magnetic Separation Rack, transfer supernatant
containing DNA carefully to a new sterile microcentrifuge tube.
20. Discard the tubes with the remaining Magnetic Nano Bead pellet. Do not reuse the beads.
Summary of Reagents Volume in Each Step
Step Buffer 8-channel Mini Midi Maxi Page
Sample
collection
Culture
volume 1-1.5 ml 1-10 ml 20-50 ml 100-200 ml P. 10
Resuspension Buffer ① 100 μl 200 μl 2 ml 6 ml P. 11
Lysis Buffer ② 100 μl 200 μl 2 ml 6 ml P. 11
Neutralization Buffer ③ 100 μl 200 μl 2 ml 6 ml P. 11
Plasmid Binding Buffer ④ 300 μl 600 μl 6 ml 18 ml P. 12
Bead Binding Magnetic
Nano Bead 25 μl 50 μl 300 μl 1.5 ml P. 12
1st, 2nd Washing 80% Ethanol 500 μl 700 μl 10 ml 30 ml P. 12
3rd Washing Buffer ⑤ 700 μl 700 μl 10 ml 25 ml P. 13
Elution Buffer ⑥ 100 μl 100 μl 500 μl 1 ml P. 13
18
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
XVII. Appendix
Troubleshooting guide
The guide will help you to solve problem that may arise during DNA extraction. For other technical
assistance or more information, please contact our technical assistance team.
Comments and suggestions
Low or no yield
Performance of buffers or other reagents may have been lowered. Please
make sure that reagents are stored at room temperature at all times upon
arrival and that all reagent bottles are closed tightly, in order to preserve
pH and stability, and to avoid contamination.
Cell debris is not fully removed. Include debris removal step, especially for
mini (8-Channel?) scale. Refer to step 4 (optional) in page 8 for detail.
The cells may not have been completely resuspended with Buffer ①
(Resuspension). Make sure that cells are completely resuspended.
Excess amount of starting sample was used to extract DNA. Add
appropriate amount of starting sample (see “Kit Specification” in page 4)
for efficient extraction of genomic DNA.
Elution may have been incomplete. Extend incubation time up to 3 minutes
at elution step to improve the yield, In addition, make sure that Magnetic
Nano Beads are suspended completely in the eluting solution during
incubation.
Pellet of Magnetic Nano Bead could be lost while discarding solution.
Check that all of the Nano Beads bind tightly to magnet when you discard
solution.
Insufficient shaking or vortexing during lysis step may lead to low DNA
yield than expected. Shake or mix with a vortex mixer sufficiently during
incubation step.
19
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
Low A260/280 ratio
Beads may have been washed insufficiently. Wash the beads properly in
the 3rd washing step. Remaining ethanol can decrease the purity of DNA.
Take enough time to properly wash the beads.
Incomplete suspension of beads during the washing step causes salts to
remain in the purified DNA. Make sure that the beads are suspended
thoroughly during the washing process.
Contamination
of chromosomal DNA
During neutralization step, it is important that you do not vortex or shake
sample tubes vigorously. Also, total lysis reaction should not be longer
than 5 min. These conditions can shear chromosomal DNA. Make sure
that the lysate was handled gently.
Aggregation of Magnetic
Nano Bead
Excess amount of starting sample is used to extract DNA. Add appropriate
amount of starting material (see “Kit Specification” in page 4) for efficient
extraction of genomic DNA.
Presence of white precipitate
in some buffer
A white precipitate may form in Buffer ④ (Binding) due to prolonged
storage at low temperatures. Incubate Buffer ④ (Binding) at 60℃ to
dissolve any precipitate in the buffer.
Too many background bands
in sequencing analysis
There may be high endonuclease activity in your strain of host E. coli, such
as HB101, JM series etc. EndA- strain instead of EndA+ strain instead.
Sample
containing RNA
RNase A activity becomes lowered, especially in the case that it has been
over 6 months since RNase A powder was added to Buffer ①
(Resuspension). Add more RNase A powder, up to 100 ng/μl, or use fresh
RNase A.
20
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
Degraded DNA
The DNA from old or inappropriately stored sample may often be
degraded. As the DNA yield is highly dependent on storage conditions of
samples, please use fresh samples for optimal results. In case of using
stored tissue sample, it is recommended to use sample stored at -70℃.
Frequent freezing and thawing may result in lower DNA yield. Avoid
repeated freezing and thawing.
Flotation of extracted DNA
when loaded on an agarose
gel
Floating of DNA on an agarose gel is caused by the remaining ethanol in
the eluted DNA. Ensure that the 3rd Washing (ethanol removing) step in the
protocol is properly performed. Remaining ethanol may also interrupt the
enzymatic reaction.
21
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
Experimental data
Figure 1. Electrophoresis data of several sizes of plasmid purified with MagListo™ 5M Plasmid Extraction Kit
M1 1 2 3 M2
M1: Bioneer 100bp ladder
1: 3.5 kb plasmid
2: 5.4 kb plasmid
3: 8 kb plasmid
M2: Bioneer 1kb ladder
Figure 2. Electrophoresis data of restriction endonuclease-treated plasmid (500 ng/lane) after extracted with
MagListo™ 5M Plasmid Extraction Kit in three different scales: mini, midi and maxi
Mini Midi Maxi
M1 1 2 3 4 5 6 7 8 9 10 M2
plasmid
insert
M1: Bioneer 100 bp ladder 1, 3: Plasmid (mini prep) 2, 4: Plasmid (mini prep) digested by EcoRI 5, 7: Plasmid (midi prep)
6, 8: Plasmid (midi prep) digested by EcoRI
9: Plasmid (maxi prep)
10: Plasmid (miaxi prep) digested by EcoRI
M2: Bioneer 1 kb ladder
22
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
Figure 3. High quality sequencing data (ABI3730) of pGEM-B1 purified with MagListo™ 5M Plasmid Extraction
Kit
23
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
XVIII. Ordering Information
Cat no. Product Description Size
K-3601 MagListoTM 5M Plamid Extraction Kit, 100 reactions (mini) 1 kit
K-3600 MagListoTM 5M Plamid Extraction Kit, 500 reactions (mini) 1 kit
K-3603 MagListoTM 5M Genomic DNA Extraction Kit, 100 reactions (mini) 1 kit
K-3605 MagListoTM 5M Plant Genomic DNA Extraction Kit, 100 reactions (mini) 1 kit
K-3607 MagListoTM 5M Gel Extraction Kit, 100 reactions (mini) 1 kit
K-3609 MagListoTM 5M PCR Purification Kit, 100 reactions (mini) 1 kit
K-3611 MagListoTM 5M Cell Total RNA Extraction Kit, 100 reactions (mini) 1 kit
K-3613 MagListoTM 5M Tissue Total RNA Extraction Kit, 100 reactions (mini) 1 kit
K-3615 MagListoTM 5M Forensic Sample DNA Extraction Kit, 100 reactions (mini) 1 kit
K-3617 MagListoTM 5M Viral DNA / RNA Extraction Kit, 100 reactions (mini) 1 kit
K-3619 MagListoTM 5M Circulating Cell Free DNA Extraction Kit, 50 reactions (mini) 1 kit
TM-1000 MagListoTM-8Ch Magnetic Separation Rack 1 ml tube x 8 holes
TM-1010 MagListoTM-2 Magnetic Separation Rack 2 ml tube x 8 holes
TM-1020 MagListoTM-15 Magnetic Separation Rack 15 ml tube x 6 holes
TM-1030 MagListoTM-50 Magnetic Separation Rack 50 ml tube x 3 holes
HT-15-NG 1.5 ml microcentrifuge tube 500 ea / pk
HT-20-NG 2 ml microcentrifuge tube 500 ea / pk
24
www.bioneer.com
BQ-042-101-01
Revision : 2 (2016-11-04)
MagListo™ 5M Plasmid Extraction Kit
XIX. Explanation of Symbols
Catalog
Number
Contains sufficient for
(n) tests USE BY
Batch code
Caution, consult
accompanying
documents
Temperature
Limitation
Manufacturer
Caution, Potential
Biohazard
DO NOT
REUSE
Consult Instruction
For Use
8-11 Munpyeongseo-ro, Daedeok-gu, Daejeon, 34302, Republic of Korea
+82-42-930-8777 (Korea: 1588-9788)
+82-42-930-8688
www.bioneer.com
1301 Marina Village PKWY, Suite 110, Alameda, CA 94501, USA
+1-877-264-4300 (Toll-free)
+1-510-865-0350
us.bioneer.com
Korea Bio Park BLDG #B-702, 700 Daewangpangyo-ro, Bundang-gu, Seongnam-si
Gyeonggi-do, 13488, Republic of Korea
+82-31-628-0500
+82-31-628-0555
www.bioneer.co.kr