magnet measurement device for mice f. garnier , p-a. giudici , f.bergsma cern
DESCRIPTION
Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN MICE Collaboration Meeting No. 30 6-9 July 2011 Oxford technical drawings by O.Jamet. Layout CM29. Rails. Trolley with B-sensors. ¼ pipe of aluminum. Cradles. Service module. Tooth belt. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/1.jpg)
Magnet Measurement Device for MICE
F. Garnier, P-A. Giudici, F.BergsmaCERN
MICE Collaboration Meeting No. 306-9 July 2011 Oxford
technical drawings by O.Jamet
![Page 2: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/2.jpg)
Layout CM29
Servo motor with encoder
Trolley with B-sensors
Rails
Cradles
¼ pipe ofaluminum
Tooth belt
Service module
![Page 3: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/3.jpg)
supports
supports
No support inside magnetindependent of magnet shape
Layout CM29
Revolving discstep size 5 degree
![Page 4: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/4.jpg)
5 m
2 m
400 mm
cradlesCradles need rectification
![Page 5: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/5.jpg)
sticks outstays inside 400 mmdiameter
Non-conducting materials usedagainst eddy currents
![Page 6: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/6.jpg)
sticks outnot inside400 mmdiam.
gearbox 1/12no clearance
![Page 7: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/7.jpg)
target support forsurvey
disk for spectrometersolenoid
disk for AFC
![Page 8: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/8.jpg)
removableextension plate
![Page 9: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/9.jpg)
detachableservice module
NMR test stand forB-sensors
Check on B-sensor calibration
For details on calibration see IMMW15 workshop
![Page 10: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/10.jpg)
Rotation in steps of 45 deg.over two axes
NMR
![Page 11: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/11.jpg)
5m version for spectrometer solenoids2m version for focus absorber solenoids.
Extension disk to by-pass internal flange AFCNeed to measure from both sides
2m version could be used to measure eventually coupling coils
Extension disk for AFC
dismountable
This flange cannot be removed andcannot be surpassed by rail support
![Page 12: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/12.jpg)
Mounting of B-sensors
main disk
![Page 13: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/13.jpg)
extension disk
Mounting of B-sensors
![Page 14: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/14.jpg)
Measurement grid
Disk can be rotated in steps of5 degree
180 mm sensor has to be removed for this region
/R140
![Page 15: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/15.jpg)
![Page 16: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/16.jpg)
Strategy mechanics:1 build 5 m version , test precision with laser tracker 2 if precision insufficient add encoder and rack and/or foresee laser tracker during measurements etc3 build 2 m version
DAQ:Build simple read-out for 7 B-sensorsAnticipate to have interface outside high field region
Accuracy:
< 0.5 mm longitudinal+/- 0.5mm radialTheta +/- 1 mradBx,By,Bz +/- 2 mT Check in situ with NMR on service module
very unlikely
![Page 17: Magnet Measurement Device for MICE F. Garnier , P-A. Giudici , F.Bergsma CERN](https://reader036.vdocument.in/reader036/viewer/2022062323/56815b28550346895dc8e736/html5/thumbnails/17.jpg)
Status
Rail support send to company to rectifyWill come back this week => bench ready for final assembly
Motion: motor with gearbox tested in vertical bench with 2.5 kgf load and 7.5 kg mass. Works fine, clearance within limits
B-sensors ready and calibrated
Read-out: basics exist ( used in calibrator with 4 cards), parts exist duplicate electronics board
Ready at August 2011 for AFC (small version)
should be send to CERN !