magnetic level indicator - orion · pdf fileevery floatis manufactured specificallyfor each...
TRANSCRIPT
MAGNETIC LEVEL INDICATOR
TM
Vector™ is a rugged, reliable and cost-
effective Magnetic Level Indicator (MLI).
Suitable for a variety of installations, Vector
has many basic features and is precision-
engineered and manufactured to ensure a
long service life.
MLIs are widely used to replace high-
maintenance sight and gauge glass
indicators and are increasingly used in
new applications. Optional switches and
transmitters are available to provide various
output signals for level control.
• Feedwater heaters
• Oil/water separators
• Flash drums
• Surge tanks
• Gas chillers
• Deaerators
• Blowdown flash tanks
• Hot wells
• Vacuum tower bottoms
• Alkylation units
• Propane vessels
• Storage tanks
...and many others
TM
2
• Rugged,industrial-gradeconstruction
• Fieldadjustablevisualindicatorforconvenientviewing
• Continuousmeasuringrangeupto216in.(549cm)
• Compatiblewithelectronicpointswitchesandcontinuousleveltransmitters
• Mediaspecificgravityaslowas0.54
• Shatter-resistantviewingwindow
• Singlemagnetperflagtoenhancefloatcouplingeffectandself-alignment
Features
Principle of Operation
Afloattravelsupanddowninachamberthatismountedtoaliquid-
containing vessel. The float contains a magnetic assembly that
interactswithanexternally-mountedvisualindicator.Asthefloat
followstheliquidsurfaceorliquid-liquidinterface,themagneticfield
causeshighlycontrastingflagsinthevisualindicatortorotate.The
resultisaclearlydefinedrepresentationoftheliquidlevelinthevessel.
TheVector™floatcontainshigh-strengthalloymagnetsthatfacilitateastrongcouplingwiththeexternally-mountedvisualindication,aswellasanyswitchesortransmitters.
Everyfloatismanufacturedspecificallyforeachapplication.Processpressure,temperature,andmediaspecificgravityareallfactoredintothecustomdesign.
The Vector™ high-visibility visual indicator is constructed withqualitymaterialsandengineeredforreliableperformance.
Eachflagcontainsanalloymagnetthatmaximizescouplingwiththefloat. Theflagsaremechanically limited toahalf-rotation,which eliminates the possibility of over-rotation commonwithothermagneticlevelindicators.
3
4 Vector™MagneticLevelIndicator
E English(inches)
M Metric(centimeters)
A 150#
B 300#
A 316/316LStainlessSteelChamber
B 316/316LStainlessSteelChamberwithCarbonSteelFittings&Flanges
C 304/304LStainlessSteelChamber
D 304/304LStainlessSteelChamberwithCarbonSteelFittings&Flanges
1 PVCplastic
2 CPVCplastic
1 IndustrialGrade
N NoChamberFlange(requiredifmodelcode3iseitherAorB)
A RaisedFaceSlip-OnFlange(requiredifmodelcode3iseither1or2)
P FullFaceSocketFlange(forPVCandCPVCmaterialonly)
A RaisedFaceFlange,Slip-OnStyle
M MaleThreaded(NPT)
R ButtWeld
1 VanStoneFlange(PVC/CPVConly)
A 1/2”
B 3/4”
C 1”
D 1-1/2”
E 2”
N None(requiredifmodelcode3iseitherAorB)
A FlexibleGraphiteRing(requiredifmodelcode3iseither1or2)
P EPDMRubber(requiredifmodelcode5iseither1or2)
N None(requiredifmodelcode3iseitherAorB)
Q AlloySteelwithCadmiumPlating(requiredifmodelcode3iseither1or2)
Connection Orientation Chamber Top Chamber BottomA Side/Side WeldedFlatCap ThreadedPlug(NPT)B Side/Side ThreadedPlug(NPT) WeldedFlatCap1 Side/Side WeldedFlatCap Flange2 Side/Side Flange WeldedFlatCap
1
2
3
3
8
4
5
6
7
8 9
10
11
1 2 3 4
ProductName
UnitofMeasureforCenter-to-Center
MountingConfiguration&ChamberConstruction
MountingConfiguration&ChamberConstruction
ProcessConnectionType
RequiredFlangeRating
MaterialofConstruction
ConstructionGrade
ChamberFlangeType
ProcessConnectionType ProcessConnectionSize
GasketStyleforChamberFlange(ifapplicable)
ChamberBoltingMaterial
5 6 7 8 9 10 11 12 13 14 15 16 17 18
OptionA
Option1
OptionARFSOFlange
OptionMThreadedNPT
OptionRButtweld
OptionB
Option2
19 20 21 22 23 24 25
4
Othergasketoptionsavailable.Consultfactory.�
N None
T TransmitterPad:RequiredforJupiterorOCTbetween165°Fto375°F(74°Cto191°C)
V Indicator&JupiterPad:Requiredbetween376°Fto850°F(192°Cto454°C)
W Indicator&OCTPad:Requiredbetween376°Fto425°F(192°Cto218°C)
Y PadforIndicatorOnly:Requiredwhentemperaturesgreaterthan375°F(191°C)
A InsulationBlanketforChamber:Optionalupto500°F(260°C)
XXX Thesecodesarefactoryassignedbasedonapplicationdata
XXX SpecifyinINCHESwhenmodelcode2isESpecifyinCENTIMETERSwhenmodelcode2isM
1 Orange/BlackFlags
2 Yellow/BlackFlags
3 Red/WhiteFlags
4 Red/SilverFlags
5 Orange/BlackFlags
6 Yellow/BlackFlags
7 Red/WhiteFlags
8 Red/SilverFlags
N None
1 Feet/Inches
2 Meters/Centimeters
3 RunningInches
4 Percent(markingsinincrementsof5%)
N None
1 JupiterTransmitter(TopMount)
2 JupiterorOCTTransmitter(TopMountOffset&TopMountHighTemperature)
3 JupiterorOCTTransmitter(BottomMount,BottomMountHighTemperature)
19
23‒25
16
1 2 3 4
MeasuringScale
Center-to-Center&VIL
OtherConsiderationsforChamberConstruction�
5 6 7 8 9 10 11 12 13 14 15 16 17
Option1OptionN Option2 Option3
18 19 20 21 22 23 24 25
17
18
19
20‒22
23‒25
InsulationOptions
MeasurementType&IndicationStyleTotallevel Interfacelevel
MeasuringScale
FactoryAssignedCodes
Center-to-Center&VisualIndicationLength
I N S T R U M E N T SI N S T R U M E N T SI N S T R U M E N T SI N S T R U M E N T S
NN None
11 1/2”NPTwithHexPlug
21 3/4”NPTwithHexPlug
14‒15 DrainSize&Type
NN None
11 1/2”NPTwithHexPlug
21 3/4”NPTwithHexPlug
12‒13 VentSize&Type
Vectorcanbecombinedwithvariousexternally-mountedaccessories,includingswitchesandtransmitters.Transmitter,however,requirestheMLIchambertobelengthenedslightlytoaccommodatetheprobe.
Refertopages6&7foradditionalinformationregardingaccessories.
5
orionxpresss h i p m e n t p r o g r a m
Expedited3 weekleadtimeatnoadditionalcost.Seebackcoverforadditionaldetails.
some restrictions apply
�
ConfigurationA
ConfigurationA
ConfigurationB
ConfigurationB
Notes:Lowerchamberdimensionvariestoaccommodateextendedfloats.Lowerspecificgravitiesnormallyresultinlongerfloatstoachieverequiredamountofbuoyancyforce.
�
�
�
�
�
UpperchamberdimensionwillvaryifaJupiterorOCTleveltransmitterisspecified.�
�
�
�
�
6
ProductName Vector™
MaterialsofConstruction–MLI 316/316Lstainlesssteel304/304Lstainlesssteel
CarbonSteelprocessconnectionsandfittingsavailable
Chamber material must be non-ferromagnetic
MaterialsofConstruction–Float Stainlesssteelandtitanium-varies depending on process conditions
ConstructionGrade Industrial
Certifiedmaterialtestreport(CMTR) Availableuponrequest
PressureClassRatings ANSI150#&300#
ProcessConnectionSizes 1/2”3/4”1”1-1/2”2”
ProcessConnectionTypes Raisedfaceslip-onstyleflange,threadednipple,buttweldnipple
MeasuringRange 12to216in(30to549cm)
TemperatureRange -40°to+500°F(-40°to+260°C)
PressureRange Fullvacuumto740psig(51.02bar)
All chambers are hydrostatically tested at 1.5x design pressure
SpecificGravityRange ≥0.54
VisualIndicators Magneticallyactuatedflagassemblyincontrastingorange/black,yellow/black,
red/white,orred/silvercolors
MaximumViewingDistance Approximately100feet(31meters)
MeasuringScale Feet/Inches,Meters/Centimeters,RunningInches
SwitchOptions ModelOESelectriccamoperatedsnapaction(refertoOrionbulletin:OES-100)
ModelORSelectricreedtype(refertoOrionbulletin:ORS-300)
TransmitterOptions Model2xxJupiterMagnetostrictive(refertoOrionbulletin:ORI-148)
ModelOCTanalogreedchain(refertoOrionbulletin:OCT-400)
HighTemperatureInsulation Fiberglassmaterialwithweather-resistantsiliconejacket
SPECIFICATIONS | VECTOR™ MAGNETIC LEVEL INDICATOR
ACCESSORIES
Model:OES10.1AmpDPDTSnapActionSwitchrefer to bulletin: OES-100
Idealforprocessmediacontainingferrousparticles.TheseparticlescanentertheMLIchamberandcoatthemagneticfloatrenderingitinoperable.Thetrapwillcollecttheseparticlessothattheycanbeperiodicallyremoved.
Model:OCTReedChainTransmitterrefer to bulletin: OCT-400
Electronic Point Level Switches
Magnetic Particle Trap
Continuous Level Transmitters
Model:ORS1AmpSPDTReedSwitchrefer to bulletin: ORS-300
Model:JupiterMagnetostrictiveTransmitterrefer to bulletin: ORI-148
7
2105OakVillaBoulevard•BatonRouge,Louisiana70815•225-906-2343•TollFree866-55-ORION(866-556-7466)•Fax225-906-2344•www.orioninstruments.com
Copyright©2012OrionInstruments,LLC.Allrightsreserved.PrintedintheUSA.Performancespecificationsareeffectivewithdateofissueandaresubjecttochangewithoutnotice.
Orion,Orionlogotype,Magnetrol,Magnetrollogotype,Aurora,andEclipseareregisteredtrademarksofMagnetrolInternational.Atlas,Gemini,Vector,Jupiter,andInstaSealaretrademarksofMagnetrolInternational.
BULLETIN: ORI-140.0EFFECTIVE: JULY 2012
REGISTERED TO ISO 9001:2008
MagnetostrictiveTansmitterDual-ChamberMLIMagneticLevelIndicator(MLI) MLIwithIntegralGuidedWaveRadar
OrionInstrumentsisdedicatedtoreducingproductleadtimesthroughongoingefficiencyinitiativesandstrategicinventorymanagement.OrionXpressisavailableforselectproductconfigurationsandwillallowyourproducttoshipwithin3weeksofplacingtheorder.
Lookfortheblueshadedoptionsthroughoutthemodelnumber: E Example
orionxpresss h i p m e n t p r o g r a m