magnew3000 plus smart electromagnetic flowmeter … · - 1 - 6th edition no. ss2-mgg200-0110...

12
- 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D Remote model (Diameter 15 to 100 mm) OVERVIEW The MagneW3000 PLUS ceramic lining detec- tor is a high-performance and highly-reliable flow meter based on Azbil Corporation's proven MagneW3000 flow measurement technologies. A broader portfolio of MagneW3000 PLUS meets various applications. FEATURES A unique high-quality electrode structure offers the strongest ceramic lining detector against thermal shock. • Ceramic lining detectors range in size from 15 mm to 100 mm are available and meet various severe applications, such as high-temperature, high-pres- sure, and wearing applications. • Mirror finish surface of the ceramic lining is avail- able for scaling applications.| • The standard accuracy is +/- 0.5 % of rate. Also available is an optional high accuracy calibration rated at +/- 0.35 % of rate (sizes of 40 mm to 100 mm (1-1/2 to 4 inches) , combined with MGG14C). APPLICATIONS Applicable to a wide range of applications in various industries. Pulp and paper Liquid, pulp, chemicals, corrosive liquids, etc. Petroleum/petrochemical/chemicals Corrosive liquids, dyes, chemicals, etc. Public utilities Service water, sewage, excrement, sludge, sedi- ment slurry etc. Steel/non-ferrous metals/ceramics Aluminum slurry, corrosive liquids, etc. Machinery/equipment/electric machinery Corrosive liquids, etc. Construction Construction material slurry, sediment slurry, cement slurry, etc. Shipbuilding Sediment slurry, etc.

Upload: ledan

Post on 17-Apr-2018

222 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

- 1 - 6th edition

No. SS2-MGG200-0110

MagneW3000 PLUS Smart Electromagnetic Flowmeter

Detector (Ceramic lining)Model MGG18D

Remote model(Diameter 15 to 100 mm)

OVERVIEWThe MagneW3000 PLUS ceramic lining detec-tor is a high-performance and highly-reliable flow meter based on Azbil Corporation's proven MagneW3000 flow measurement technologies.A broader portfolio of MagneW3000 PLUS meets various applications.

FEATURES

• A unique high-quality electrode structure offers the strongest ceramic lining detector against thermal shock.

• Ceramic lining detectors range in size from 15 mm to 100 mm are available and meet various severe applications, such as high-temperature, high-pres-sure, and wearing applications.

• Mirror finish surface of the ceramic lining is avail-able for scaling applications.|

• The standard accuracy is +/- 0.5 % of rate. Also available is an optional high accuracy calibration rated at +/- 0.35 % of rate (sizes of 40 mm to 100 mm (1-1/2 to 4 inches) , combined with MGG14C).

APPLICATIONS

Applicable to a wide range of applications in various industries.

Pulp and paperLiquid, pulp, chemicals, corrosive liquids, etc.

Petroleum/petrochemical/chemicalsCorrosive liquids, dyes, chemicals, etc.

Public utilitiesService water, sewage, excrement, sludge, sedi-ment slurry etc.

Steel/non-ferrous metals/ceramicsAluminum slurry, corrosive liquids, etc.

Machinery/equipment/electric machineryCorrosive liquids, etc.

ConstructionConstruction material slurry, sediment slurry, cement slurry, etc.

ShipbuildingSediment slurry, etc.

Page 2: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

No. SS2-MGG200-0110 Azbil Corporation

- 2 -

FUNCTIONAL SPECIFICATIONS

Type of protectionJIS C 0920 waterproof modelNEMA ICS6-110 TYPE4IEC PUBL 529 IP66

Ship classificationApproved by NK (Nippon Kaiji Kyokai)Approval No.: 11A008

Note: The MGG18D cannot be installed on the bridge or deck of the ship.In the case of a remote model, the cables between the converter and detector must be covered with a flexible metal conduit.

Temperature range of liquid to be measuredCeramic lining

Thermal shockIncrease T= 150°C (270°F)/sec max.Decrease T= 100°C (180°F)/sec max.

Measurable process fluid pressure

Measurable electrical conductivityCombined with model MGG14C converter 3 μS/cm or more (in case of less than 3 μS/cm, consult an Azbil Corp. representative)

Vibration effectIntegral style: 4.9 m/s2(0.5G) max.Remote style converter: 4.9 m/s2(0.5G) max.Remote style detector: 19.6 m/s2(2G) max.

Measurement flow range Refer to the minimum/maximum set ranges shown in the table below.

Measurement flow velocity range 0 to 10 m/s

Flange ratingJIS 10K, 20K, 30K, 40KANSI 150, 300, JPI 150, 300DIN PN10, 16, 25, 40JIS G3443-2 F12 (diameter 80 to 100 mm)

Reference flange standardJIS; JIS B2210 (1984)ANSI; ANSI B16.5 (1988)JPI; JPI-7S-15-93

Ambient temperature limits-25 to +60°C (integral model)-30 to +80°C (integral model)

Ambient humidity limits10 to 90 % RH

Optional specifications

Test reportCalibration certificate, withstand voltage test, insu-lation resistant, hydrostatic pressure test, physical inspection are included.

Traceability certificateThe following three documents are included.

• Traceability system chart• Traceability certificate• Test report

Attaching the tag number to the terminal boxStamp the tag with the specified number and attach to the terminal box. The maximum number of char-acters in the tag number is 8.

Attaching the tag number to the neck sectionStamp the tag with the specified number and attach to the neck section of the detector. The maximum number of characters in the tag number is 16.

Diameter (mm)

Temperature of the liquid to be measured

Integral model Remote model

15 to 100 -40 to +120°C -40 to +180°C

3.92MPa

-0.098 MPa-40 C 120 C

Integral style

3.92MPa

-0.098 MPa-40 C 180 C

Remote style

Diameter (mm)

Minimum set range (m3/h) (Minimum

constant flow speed of 0 to 0.1

m/s)

Maximum set range (m3/h) (Maximum

constant flow speed of 0 to 0.1

m/s)

Flow conversion

factor K

15 0 to 0.0637 0 to 6.36 1.572

25 0 to 0.177 0 to 17.6 0.5659

40 0 to 0.453 0 to 45.2 0.2210

50 0 to 0.707 0 to 70.6 0.1415

80 0 to 1.81 0 to 180 0.005526

100 0 to 2.83 0 to 282 0.03537

Page 3: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

Azbil Corporation No. SS2-MGG200-0110

- 3 -

Mirror finish for ceramic liningPolish the surface of ceramic lining.

For additional specifications, please contact the Azbil Group representative.

PERFORMANCE SPECIFICATIONS

Accuracy(in combination with the model MGG14C converter)<diameter 15 mm>Vs = Velocity of setting range

<diameter 25 to 100 mm>Vs = Velocity of setting range

*)High accuracy calibration is available for sizes of 40 to 100mm (1½ to 4 inches).Reference Conditions for high accuracy calibration:

• Fluid:Tap water• Fluid temperature:15 to 30°C• Ambient temperature:15 to 30°C• Ambient humidity:30 to 70 %• Lengh of straight pipe:

Upstream > 20×DNDownstream > 5×DN(DN:Pipe diamter nominal)

• Properly grounded• Properly centered

Accuracy is guaranteed by the totalized flow volume under the condition of continuous flow measurement for 30 seconds or longer.

PHYSICAL SPECIFICATIONS

FinishCorrosion-preventive acrylic resin

ColorLight beige (Munsell 4Y7.2/1.3, terminal box)Dark beige (Munsell 10YR4.7/0.5, detector housing)

Main body material

Measuring pipe materialCeramic (Al2O3 99.7 %)

Housing Cast steel (diameter 15, 25 mm) Aluminum alloy (diameter 40 to 100 mm)

Terminal box Aluminum alloy (remote model)

Material of parts in contact with liquid

LiningCeramic (Al2O3 99.7 %)(diameter 15 to 100 mm)

ElectrodeSUS316L, Hastelloy C, Titanium, Zirconium, Tan-talum, Tungsten-carbide, Platinum-iridium

Grounding ringNone, Platinum metallize

Structure of electrodeInternal insertion type(electrode can not be removed)

Vs (m/s)Velocity during

measurement > Vs × 40 %

Velocity during measurement < Vs

× 40 %

1.0 < Vs < 10 ± 0.5 % of rate ± 0.2 % of Vs

0.1 < Vs < 1.0 ± (0.1/Vs+0.4)% of rate

± 0.4(0.1/Vs+0.4)% of Vs

Vs (m/s)

Velocity during measurement > Vs × 20 %

Standard Accuracy

(Calibration Code A)

*)High Accuracy (Calibration Code

U)

1.0 < Vs < 10 ±0.5 % of rate ±0.35 % of rate

0.1 < Vs < 1.0±(0.1/Vs+0.4)% of

rate±(0.1/Vs+0.25)% of

rate

Vs (m/s)

Velocity during measurement < Vs × 20 %

Standard Accuracy

(Calibration Code A)

*)High Accuracy (Calibration Code

U)

1.0 < Vs < 10 ±0.1% of Vs ±0.07% of Vs

0.1 < Vs < 1.0±0.2(0.1/

Vs+0.4)% of Vs±0.2(0.1/Vs+0.25) %

of Vs

Page 4: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

No. SS2-MGG200-0110 Azbil Corporation

- 4 -

INSTALLATION

Electrical connection

Integral modelConnection to converter

Remote modelG1/2 (PF1/2) internal thread, 1/2 NPT internal thread, CM20 internal thread, Pg 13.5 internal thread

Pipe connectionWafer

GroundingResistance lower than 100 Ω

MountingHorizontally-mounted electrode

Length of straight pipe

Upstream sideA minimum five straight pipe diametersA minimum 10 straight pipe diameters is required if a diffuser/valve/pump is installed upstream side.

Downstream sideTwo straight pipe diameters is recommended.

Cable (between remote detector and con-verter)

Maximum length300 m (depending on fluid conductivity)

Outer diameter10 to 12 mm

Signal cable

Dedicated cable (11.4 mm, 0.75 mm2)or equivalent (CVVS, CEEV, etc.)

Excitation cableDedicated cable MGA12W

(O.D. 10.5 mm, 2 mm2)or equivalent (CVV and others)

Maximum cable length of MGA12W cable

detector

detector

detector

detector

detectordetector

Right-angle joint

Upstream side

Greater than 5 dia.

T joint

Gate Value(completely open)

Greater than 5 dia.

Greater than 5 dia.

Greater than 5 dia.

Greater than 10 dia.

Greater than 10 dia.

Greater than 10 dia.

Any Control Value

Concentrator(considered as

straight-pipe section)

Any pump

Diffuser with cone angle greater than 15

(If cone angle is 15 or less, considered as straight pipe)

P

Figure 1

Figure 2 Maximum cable length of MGA12W cable

300

2

5

10

20

200

50

100

13 5 10 20 50 100 200 500 1000

Process fluid conductivity [µ S/cm]

Cab

le le

ng

th [m

]

Page 5: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

Azbil Corporation No. SS2-MGG200-0110

- 5 -

Notice for installation

To fully enjoy the performance of the device, please choose an appropriate location according to the fol-lowing.

Notice after installation

� WARNING

When removing the device from the piping, make sure that there is no line pressure or process fluid inside of the device. Removing the device before depressurizing may result in serious injury.

� CAUTION

Do not use the device as a foothold. It may cause injury or damage of the device.

Notice for environment• Install the flowmeter in a location with an

ambient temperature of -25°C to 60°C (-13°F to 140°F) and an ambient humidity of 5 to 100 %RH to prevent equipment malfunction or out-put errors.

• Do not install the flowmeter near high-current power lines, motors or transformers to prevent damage from electromagnetic induction, which can cause equipment malfunction or output errors.

• Do not install the flowmeter in a location sub-ject to severe vibration or in a highly corrosive

atmosphere. The converter and detector can be damaged.

• When install some electromagnetic flowmeters in closer location, keep minimum 500 mm (20 inch) space from each flowmeter. Closer elec-tromagnetic flowmeter installation may cause magnetic interference each other and results in output errors.

Notice for application• Electrochemically homogeneous fluid

Install the device where the process fluid is electrochemically homogeneous. If two kind of process fluids are mixed at the upstream side, the process fluid must be uniformly mixed.

• The application which the electric conductivity changes or non-homogeneous fluidDo not use the device for the following fluid conditions even if the electric conductivity, temperature, and pressure are within the device specifications. Those fluid may cause of inac-curate flow measurement.

• Fluids that have sufficient conductivity at high temperature but do not meet the conductivity requirement at room temperature (about 20°C (68°F)).(e.g. fatty acids and soap)

• Some fluids contain surfactant(e.g. rinse, shampoo and CWM (coal water mix-ture))

• Insulating adhesive materials(eg. kaolinite, kaolin, calcium stearate)

Page 6: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

No. SS2-MGG200-0110 Azbil Corporation

- 6 -

MODELSELECTIONS

Wafer type (15 to 100 mm ) Ceramic (Al203 99.7 %) linerModel MGG18D - I II III IV V VI VII VIII IX - X XI - Y/Options (some options can be selected per each model)

Basic model no. Selections Optional selections

Note: 1. This specification (without grounding ring) is applicable when the grounding is possible through pipe line. In case of plastic pipes or lined pipes, this selection is not applicable. Please select “M” as grounding ring selection code.2. Must be selected for CSA/FM NI approval

Remote type Integral type

Note: 3. Must be selected for Tag no. requirement

MGG18D - -

I Line size 15 mm 01525 mm 02540 mm 04050 mm 05080 mm 080100 mm 100

II Linear Ceramic (Al2O3 99.7 F%) C

III Piping connection Wafer JIS 10K 11Wafer JIS 20K 12Wafer JIS 30K 13Wafer ANSI 150 21Wafer ANSI 300 22Wafer JIS G3443-2 F12 (Size 80 mm or larger) 31Wafer DIN PN10 41Wafer DIN PN16 42Wafer DIN PN25 43Wafer DIN PN40 44Wafer JPI 150 61Wafer JPI 300 62

IV Electrode SUS316L LASTM B574 (Hastelloy C-276 equivalent) CTitanium KZirconium HTantalum TTungsten carbide WPlatinum iridium for ceramic lining P

V Grounding ring None (Note 1) XPlatinum metallize M

VI Electrical connec-tion / watertight gland

Integral type 1Remote type

G1/2 internal thread / without watertight gland 2G1/2 internal thread / with brass (Ni-plated) watertight gland 3G1/2 internal thread / with plastic watertight gland 41/2NPT internal thread / without watertight gland (Note 2) 5CM20 internal thread / without watertight gland 6Pg 13.5 internal thread / without watertight gland 7G1/2 internal thread / with SUS304 watertight gland 8

VII Face-to-face dimensions

Standard A

VIII Installation / wir-ing direction

Integral type HRemote type

Upstream side (horizontal / vertical piping mounting) ADownstream side (horizontal / vertical piping mounting) BHorizontal piping mounting / left side viewed from upstream CHorizontal piping mounting / right side viewed from upstream D

IX Calibration Standard A

+/- 0.35 % of rate calibration (Size 40 to 100 mm (1 1/2 to 4 inches)) UOthers

X Finish Standard XCorrosion-resistant finish 1Corrosion-proof finish 2

XI Bolt / nut None XCarbon steel 1SUS304 2

Opt

ions Azbil Corporation version (must be selected) Y

Opt

ions Azbil Corporation version (must be selected) Y

Calibration certificate (sent to ordering location separately) A Calibration certificate (sent to ordering location separately) ATraceability certificate for detector B Traceability certificate for detector BAttachment of the TAG number plate to neck section for detec-tor (Note 3)

LAttachment of the TAG number plate to neck section for detector (Note 3)

L

Mirror-finish ceramic lining U Mirror-finish ceramic lining U

Page 7: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

Azbil Corporation No. SS2-MGG200-0110

- 7 -

DIMENSIONS

Integral style (15 to 25 mm) (Unit : mm (inch))

Integral style (40 to 100 mm)

Sizemm 15 25 40 50 80 100

(inches)

Face to face dimension L mm 56 56 80 86 106 120(inches)

Height

H1 mm 82 89 88 95 109 121(inches)

H2 mm 73 80 55 64 78 90(inches)

H3 mm 314 328 302 318 346 370(inches)

Width W mm 84 94 116 132 161 185(inches)

Outer diameter D mm 48.5 65 86 102 132 156(inches)

Weight included a converter model MGG14C

kg 5.5 5.5 5.2 5.8 7.6 9.0(lb)

Page 8: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

No. SS2-MGG200-0110 Azbil Corporation

- 8 -

Remote style (15 to 25 mm) (Unit : mm (inch))

Remote style (40 to 100 mm)

Sizemm 15 25 40 50 80 100

(inches)

Face to face dimension Lmm 56 56 80 86 106 120

(inches)

Height

H1mm 82 89 88 95 109 121

(inches)

H2mm 73 80 55 64 78 90

(inches)

H3mm 202 216 190 206 234 258

(inches)

H4mm 107 114 113 120 134 146

(inches)

Width Wmm 84 94 116 132 161 185

(inches)

Outer diameter Dmm 48.5 65 86 102 132 156

(inches)

Weight (kg)kg 2.5 2.8 2.4 3.0 4.8 6.3(lb)

X

Y

A

B

C

Terminal connection table

Symbol Description

Excitationcurrent input

Flow ratesignal output

Page 9: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

Note

Page 10: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

Note

Page 11: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

Note

Page 12: MagneW3000 PLUS Smart Electromagnetic Flowmeter … · - 1 - 6th edition No. SS2-MGG200-0110 MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector (Ceramic lining) Model MGG18D

Please, read ‘Terms and Conditions’ from following URL beforethe order and use.

http://www.azbil.com/products/bi/order.html

(11)

1-12-2 Kawana, FujisawaKanagawa 251-8522 Japan

http://www.azbil.com/

Specifications are subject to change without notice.

No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation.

1st edition: Feb. 19976th edition: July 2015