TRANSFORMERS, INDUCTORS, POWER SUPPLY UNITS

441

TRANSFORMERS442

POWER SUPPLY UNITS447

ELECTRONIC TRANSFORMERS451

441

441

KAPITEL_09_AK1 24.03.2005 17:45 Uhr Seite 441

Page 2: Main Catalogue 9 Transformerer Power Supply

W TECHNICAL DATA• EN 61 558

• Taps, primary side ± 5%

• Finger-proof terminals according to VBG4

• Temperature class T 40/E

• Frequency 50/60 Hz

• Primary voltages: 400 V or 230 V, others upon request

• Secondary voltages: 230 V, 24 V, or 12 V, others upon request

• With optional fuse: LP 61....

• Optional snap-on fastening for DIN rail mounting (up to 200 VA): LP699001—

W OVERVIEW TABLE

POWER RATING VA 400/230 400/24 230/230 230/24 230/12

30 - LP603003 - LP602003 LP601003

40 - - - LP602004 LP601004

50 LP604005 - - LP602005 LP601005

63 - - - LP602006 LP601006

100 LP604010 LP603010 LP605010 LP602010 LP601010

160 LP604016 LP603016 - LP602016 LP601016

200 LP604020 LP603020 - LP602020 LP601020

250 LP604025 LP603025 LP605025 LP602025 -

320 LP604032 - - LP602032 -

400 LP604040 LP603040 - LP602040 -

500 LP604050 LP603050 LP605050. LP602050 -

630 LP604063 - - LP602063 -

700 - - - LP602070 -

800 LP604080 - - LP602080 -

1000 LP604100 - LP605100 LP602100 -

W GENERAL NOTESThe safety features of installing devices and controls have become more and more important. The use of transformers to

provide protective electric separation and extra-low voltage safety is a simple way of increasing the safety characteristics of

a device or control. Transformers are isolating and safety transformers in one. Safety- or isolating transformers with

enhanced or double insulation.

They have been constructed and tested according to EN 61558. Isolating transformers are used when a high degree of

protection is required between input and output winding. The maximum output voltage of isolating transformers is 1000 V

AC.

Safety transformers are isolating transformers with an output voltage of ≤ 50 V AC. They are predominantly used in

systems with extra low-voltage safety (SELV).

These transformers are also control transformers used to supply control circuits. They have been built and tested in

accordance with EN 61558. EN 60 204 prescribes the use of a transformer in only two exceptional instances involving

control circuits. The control transformers meet all requirements set out in this directive.

W CONTROL-, ISOLATING- AND SAFETY TRANSFORMERS

TRANSFORMERS

442

KAPITEL_09_AK1 24.03.2005 17:45 Uhr Seite 442

Page 3: Main Catalogue 9 Transformerer Power Supply

TRANSFORMERS

443

Terms

• Rated values

Rated values are rated voltage, rated currents (rms values), rated power output, rated frequency and rated transfor-

mation ratio, with which transformers are labelled and for which they have been measured and established.

• Rated input voltage

The rated input voltage is the supply voltage of a transformer under pre-defined operating conditions.

• Rated output voltage

The rated output voltage is the voltage at the output end of a transformer with a rated input voltage, rated

frequency, rated output current and rated power factor.

• No-load voltage

The no-load voltage is the output voltage of an unloaded transformer at the rated frequency.

• No-load current

The no-load current is the current at the input end of an unloaded transformer at the rated input voltage and rated

frequency.

• Rated power

The rated power is the power at the output side of the transformer. It is the product of the rated output voltage and

rated output current. If the transformer has additional secondary taps, the rated power is the sum of the products of

rated output voltage and rated output current of all loadable control circuits at the same time.

• Stand-by power

The stand-by power is the power on the output end of a control transformer when the p.f. = 0,5 and given a maxi-

mum voltage drop of 5% compared with the rated output voltage.

• Short-circuit voltage

The short-circuit voltage is the voltage which must be produced in the input winding in order that the rated output

current still flows even with a short-circuit on the secondary side (windings at room temperature). It is expressed as a

% of the rated input voltage.

• No-load losses = core losses

The active input with a rated input voltage on the input winding at the rated frequency and the output winding is

unloaded.

• Short-curcuit losses = copper losses

The active input when there is a short-circuit across the secondary side at rated output current.

KAPITEL_09_AK1 24.03.2005 17:45 Uhr Seite 443

Page 4: Main Catalogue 9 Transformerer Power Supply

Quality

• Core

Dynamo sheets or cold-rolled grain-oriented electric plates are used to form the core.

• Windings

Both the input and output windings are made from enamel-insulated copper wire. To ensure optimal heat transfer

and resistance to moisture, the windings are soaked in resin in a vacuum before being oven-baked.

• Insulation class

The transformers are designed according to insulation class B. This means a maximum continuous temperature of

130° C. According to IEC 85 und IEC 216, other standard insulation classes are: A (105° C), E (120° C) and

F (155° C).

• Degree of protection:

The transformers have the degree of protection IP00 as standard. Accessories can be used to increase this degree of

protection to IP 23 or IP 65.

W THE NEW EUROPEAN TRANSFORMER STANDARD EN61558:The standard EN61558 is the first European standard to cover all types of transformers.

Part EN61558-1

This standard is the basic part and describes the underlying requirements for transformers, supply currents, etc..

This standard replaces: VDE0550 part 1-6

VDE0551

EN60742

Part EN61558-2-1

This standard is for small transformers for general application.

It applies to: Single-phase transformers up to 1 kVA

Three-phase transformers up to 5 kVA

This standard replaces: VDE0550

Part EN61558-2-2

This standard applies to control transformers and applies to all newly developed transformers.

All transformers produced after 31/12/2001 must meet this standard.

Part EN61558-2-4

This standard is for isolating transformers (Usec > 50 V and < 1000 V).

It applies to: Single-phase transformers up to 25 kVA

Three-phase transformers up to 40 kVA

Part EN61558-2-6

This standard is for safety transformers (Usec < 50 V)

It applies to: Single-phase transformers up to 25 kVA

Three-phase transformers up to 40 kVA

This part is binding for all newly-developed transformers.

The entire range of Schrack safety and isolating transformers have been produced to this standard since 1/7/2001.

The ÖVE mark has been replaced by the ENEC mark.

W CAUTION:The copper weight, where specified, has not been included in the calculated price.

TRANSFORMERS

444

KAPITEL_09_AK1 24.03.2005 17:45 Uhr Seite 444

Page 5: Main Catalogue 9 Transformerer Power Supply

W TECHNICAL DATA• Primary voltage 400 V, others upon request

• Secondary voltage 230 V, others upon request

• With optional fuse: ... secondary (SIS)

• All transformers with a secondary voltage < 50 V

have been designed and are labelled as safety trans-

formers.

• No package screws, fastening holes freely accessible

W CERTIFICATIONSEN 61 558

PGR 4540W SINGLE PHASE CONTROL TRANSFORMERS

TRANSFORMERS

445

f

bb1

ea

c

g

bis 2500 VA

masstabelle_einphasentrafos.eps

lp612006.eps lp60x_m2.eps

DESCRIPTION DIM. (WXHXD) PU CU WEIGHT WEIGHT ORDER NO.

230/12 V 30 VA 85x77x91 1 500 1,5 LP601003T-

230/12 V 60 VA 85x77x91 1 600 1,5 LP601006T-

230/12 V 100 VA 85x91x91 1 600 2 LP601010T-

230/12 V 160 VA 85x118x103 1 600 2,3 LP601016T-

230/12 V 200 VA 106x103x124 1 1000 3 LP601020T-

230/12 V 315 VA 121x107x131 1 1300 4,3 LP601032T-

230/12 V 500 VA 121x89x117 1 1500 6,8 LP601050T-

230/24 V 30 VA 85x77x91 1 500 1,5 LP602003T-

230/24 V 60 VA 85x77x91 1 600 1,5 LP602006T-

230/24 V 100 VA 85x91x91 1 600 2 LP602010T-

230/24 V 160 VA 85x100x91 1 600 2,3 LP602016T-

230/24 V 200 VA 106x85x112 1 1000 3 LP602020T-

230/24 V 250 VA 106x112x124 1 1000 3,8 LP602025T-

KAPITEL_09_AK1 24.03.2005 17:45 Uhr Seite 445

Page 6: Main Catalogue 9 Transformerer Power Supply

DESCRIPTION DIM. (WXHXD) PU CU WEIGHT WEIGHT ORDER NO.

230/24 V 315 VA 121x107x131 1 1300 3 LP602032T-

230/24 V 400 VA 121x119x131 1 1300 5,2 LP602040T-

230/24 V 500 VA 121x139x131 1 1500 6,8 LP602050T-

230/24 V 630 VA 151x108x211 1 2000 7,7 LP602063T-

230/24 V 800 VA 151x125x211 1 2300 9,6 LP602080T-

230/24 V 1000 VA 151x151x211 1 3000 13,4 LP602100T-

400/24 V 30 VA 85x77x91 1 500 1,5 LP603003T-

400/24 V 100 VA 85x91x91 1 600 2 LP603010T-

400/24 V 160 VA 85x100x91 1 600 2,3 LP603016T-

400/24 V 200 VA 106x85x112 1 1000 3 LP603020T-

400/24 V 250 VA 106x112x124 1 1000 3,8 LP603025T-

400/24 V 400 VA 121x119x131 1 1000 5,2 LP603040T-

400/24 V 500 VA 121x139x131 1 1500 6,8 LP603050T-

400/230 V 60 VA 85x77x91 1 600 1,5 LP604006T-

400/230 V 100 VA 85x91x91 1 600 2 LP604010T-

400/230 V 60 VA 85x100x91 1 600 2,3 LP604016T-

400/230 V 200 VA 106x85x112 1 1000 3 LP604020T-

400/230 V 250 VA 106x94x112 1 1000 3,8 LP604025T-

400/230 V 320 VA 121x89x119 1 1300 4,3 LP604032T-

400/230 V 400 VA 121x101x119 1 1300 5,2 LP604040T-

400/230 V 500 VA 121x121x119 1 1500 6,8 LP604050T-

400/230 V 630 VA 151x108x145 1 2000 7,7 LP604063T-

400/230 V 1000 VA 151x151x145 1 3000 13,4 LP604100T-

400/230 V 1600 VA 195x152x174 1 4500 17,4 LP604160T-

400/230 V 2000 VA 195x154x174 1 5500 21,5 LP604200T-

400/230 V 2500 VA 195x160x186 1 5500 21,5 LP604250T-

400/230 V 3000 VA 230x185x295 1 8000 26 LP604300T-

400/230 V 4000 VA 230x210x295 1 10400 35 LP604400T-

230/230 V 100 VA 85x91x91 1 600 2 LP605010T-

230/230 V 250 VA 106x94x112 1 1000 3,8 LP605025T-

230/230 V 500 VA 121x121x119 1 1500 6,8 LP605050T-

230/230 V 1000 VA 151x151x145 1 3000 13,4 LP605100T-

230/230 V 1300 VA 175x141x157 1 4000 14,9 LP605130T-

230/230 V 2000 VA 195x154x174 1 5500 21,5 LP605200T-

230/230 V 2500 VA 195x160x186 1 5500 21,5 LP605250T-

230/115 V 1000 VA 151x151x145 1 3000 13,4 LP606100T-

230/24 V 30 VA sec. fuse 85x77x91 1 500 1,5 LP612003T-

230/24 V 60 VA sec. fuse 85x77x91 1 600 1,5 LP612006T-

230/24 V 100 VA sec. fuse 85x77x91 1 600 3 LP612010T-

230/24 V 200 VA sec. fuse 106x85x112 1 1000 3 LP612020T-

230/24 V 250 VA sec. fuse 106x112x124 1 1000 6,8 LP612025T-

TRANSFORMERS

446

KAPITEL_09_AK1 24.03.2005 17:45 Uhr Seite 446

Page 7: Main Catalogue 9 Transformerer Power Supply

POWER SUPPLY UNITS

447

W TECHNICAL DATA• Taps, primary side ± 5%

• Input voltage 230 V 50/60 Hz, others upon request

• Output voltage 24 V DC according to EN 61558 & EN 61131,

Other voltages upon request

• Residual ripple < 5%

• Primary protection: thermal release, secondary side: replacable fuse

• Self-cooling

• LED function display

• With double insulation

• Operating temperature: -25° C to +40° C

• Storage temperature: -25° C to +65° C

W CERTIFICATIONSEN 60742 T2-6

W CAUTION:The copper weight, where specified, has not been included in the calculated price.

PGR 4540W UNSTABILISED SINGLE-PHASE DC SUPPLYFULLY ENCAPSULATED, 1,5 TO 10 A

OUTPUT CURRENT/MAX. POWER OUTPUT/OUTPUT VOLTAGE DIM. (WxHxD) PU TYPE WEIGHT ORDER NO.

1,25 A/30 W/24 V DC 51x90x65 1 LP746101 0,3 LP746101—

2.5 A/30 W/12 V DC 51x90x65 1 LP7431C2 0,3 LP7431C2—

W TECHNICAL DATA• Supply voltage: 230 V AC

• Frequency range: 48-63 Hz

• Output voltage: 12 V DC or 24 V DC

• Power loss: 4 VA

• Storage temperature: -20° to +60° C

• Ambient operating temperature: -20° to +40° C

• Test voltage: 4 kV

• Degree of protection: IP 20

• Terminals: 2.5 mm2

W CERTIFICATIONSEN 60742

PGR 4546W STABILISED POWER SUPPLIES, INSTALLATION DESIGN TYPE

lp746101.eps

DESCRIPTION DIM. (WxHxD) PU CU WEIGHT WEIGHT ORDER NO.

230/24 V 1,5 A unstabilised 121x100x77 1 380 1,4 LP7331B1I—

230/24 V 3 A unstabilised 133x108x89 1 600 1,8 LP733103I—

230/24 V 5 A unstabilised 133x121x89 1 660 2,7 LP733105I—

230/24 V 10 A unstabilised 172x152x110 1 1300 5,2 LP733110I—

lp7331_m5.eps

KAPITEL_09_AK1 24.03.2005 17:45 Uhr Seite 447

Page 8: Main Catalogue 9 Transformerer Power Supply

W TECHNICAL DATA• Stabilised supply voltage and current

• Input range from 0,9 Un to 1,1 Un

• Input voltage 230 V 50/60 Hz or input voltage 400 V 50/60 Hz,

others upon request

• Output voltage 24 V DC according to EN 61 558 / EN 61 131

• Residual ripple < 150 m Vpp

• Thermal release on primary side;

electronic current limiter on secondary side

• With double insulation

• LED function display

• Short-circuit and tamper-proof

• Self-cooling

• Operating temperature: -25° C to +40° C

• Storage temperature: -25° C to +65° C

W CERTIFICATIONSEN 60,742 T2-6

W CAUTION:The copper weight, where specified, has not been included in the

calculated price.

PGR 4540W STABILISED SINGLE-PHASE DC SUPPLYFULLY ENCAPSULATED, 1,5 TO 5 A

POWER SUPPLY UNITS

448

lp7231_m2.eps

DESCRIPTION DIM. (WxHxD) PU CU WEIGHT WEIGHT ORDER NO.

230/24 V 1,5 A stabilised 121x117x77 1 380 1 LP7231B1I-

230/24 V 3 A stabilised 133x124x89 1 600 1,3 LP723103I-

230/24 V 5 A stabilised 172x170x107 1 660 1,6 LP723105I-

lp723_mtab.eps

KAPITEL_09_AK1 24.03.2005 17:45 Uhr Seite 448

Page 9: Main Catalogue 9 Transformerer Power Supply

POWER SUPPLY UNITS

449

W TECHNICAL DATA• Output voltage 24 V DC

according to DIN 19240

• Residual ripple < 5%

• Self-cooling

• Taps, primary side ± 5%

W CERTIFICATIONSEN 61 558

W SINGLE-PHASE DC SUPPLY,FILTERED OUTPUT UP TO 25 A

lp702110.eps lp7021m1.eps

LP7031B1LP703103LP703105LP703108LP703110

Typ Current WeightDimensions in mm kgA / DC

1,5 3 5

8 10

a b1 e f g

1,4 2 2,53,654,45

85 85 85106121

71 85 93 95100

60 74 83 87 86

130130130146164

64 64 6480,5 90

4,8 4,8 4,8 5,8 5,8

46,560,5 6969,5 70

b c

LP703115LP703120LP703125

1520

25

8,5511,1014,80

151 151 151

130 130 147

104 121 147

248248248

122122122

7 7 7

82 99125

lp7021m2.eps

masstab_einphasennetzg_230.eps

DESCRIPTION DIM. (WxHxD) PU CU WEIGHT WEIGHT ORDER NO.

230-400/24 V 3 A 85x98x135 1 400 2,5 LP702103T-

230-400/24 V 5 A 106x92x151 1 600 3 LP702105T-

230-400/24 V 8 A 121x105x169 1 850 4 LP702108T-

230-400/24 V 10 A 121x137x169 1 1100 6,8 LP702110T-

230-400/24 V 15 A 151x135x253 1 1400 11,1 LP702115T-

230-400/24 V 20 A 151x152x253 1 1700 14 LP702120T-

230-400/24 V 25 A 151x152x253 1 2500 14,8 LP702125T-

PGR 4540W 230/400 V 50/60 Hz

DESCRIPTION DIM. (WxHXD) PU CU WEIGHT WEIGHT ORDER NO.

230/24 V 1,5 A 85x76x135 1 170 1,4 LP7031B1T-

230/24 V 3 A 85x85x130 1 170 2,5 LP703103T-

230/24 V 5 A 85x90x135 1 280 2 LP703105T-

230/24 V 8 A 106x100x151 1 540 3,65 LP703108T-

230/24 V 10 A 121x105x169 1 780 4,45 LP703110T-

230/24 V 15 A 151x135x253 1 1600 11,1 LP703115T-

230/24 V 20 A 151x135x253 1 2000 8,55 LP703120T-

PGR 4540W 230 V 50/60 Hz

KAPITEL_09_AK1 24.03.2005 17:45 Uhr Seite 449

Page 10: Main Catalogue 9 Transformerer Power Supply

W SUPPLY VOLTAGE 3 A STABILISED

DESCRIPTION DIM. (WxHxD) PU CU WEIGHT WEIGHT ORDER NO.

400/24 V 5 A 85x95x135 1 280 2,5 LP704105T-

PGR 4540W 400 V 50/60 Hz

POWER SUPPLY UNITS

450

WTECHNICAL DATAThe NG 24 supply voltage is a compact, dimensioned and good value module designed for

rapid mounting using a snap-on fastening mountable on DIN rails.

Upon request, the NG 24 power supply can also be integrated into transformers.

• Input: max. 30 V AC/DC

• Output: Stabilised 24 V DC,

• Max. 1% variance with current consumption 3 A

• Short-circuit proof

• Fine-wire fuse 20 x 5, 6,3 A, quick-break

• Adjustable output voltage 16-28 V DC

• Ex-factory setting 24 V DC

• Residual ripple ≤ 1%

PGR 4090W NG 24/3 A

DIM. (WxHxD) PU ORDER NO.

85x65x72 1 YY494012—

W TECHNICAL DATAThe NG 12 supply voltage is a compact, dimensioned and good value module designed for

rapid mounting using a snap-on fastening mountable on DIN rails.

Upon request, the NG12 power supply can also be integrated into transformers.

• Input: 15 V AC/DC

• Output: Stabilised 12 V DC

• Max. 1% variance with current consumption ≤ 2,2 A

• Short-circuit proof

• Fine-wire fuse 20 x 5, 6,3 A, quick-break

• Adjustable output voltage 5-15 V DC

• Ex-factory setting 12V DC

• Residual ripple ≤ 1%

• Design type for enclosures, can be snapped onto DIN rail

• Input voltage 28 V ± 15% to 10%, 16 - 63 Hz

• Output voltage: continuously adjustible between 5 - 24 V using LED display

• Output current = 2,5 A

PGR 4090W NG 12/3 A

yy494004.eps

DIM. (WxHxD) PU ORDER NO.

85x65x72 1 YY494004-A

yy494004.eps

KAPITEL_09_AK1 24.03.2005 17:45 Uhr Seite 450

Page 11: Main Catalogue 9 Transformerer Power Supply

ELECTRONIC TRANSFORMERS

451

W 2 INPUT AND 3 OUTPUT TERMINALS, OPPOSED

DESCRIPTION DIM. (WxHxD) PU TYPE ORDER NO.

Micro 60 PFS, 10 - 60 VA 31x91x20 1 RN 1608 YY160800—

FOXS 105 PFS, 20 - 105 VA 38x112x28 1 RN 1600 YY160000—

W INPUT AND OUTPUT TERMINAL ON SAME SIDE

W TECHNICAL DATA• Meets EURONORM EN 61046/61047

• protection class II

• Rated voltage: 230 V/50-60 Hz/12 V

• Suitable for mounting onto combustible base

• Tamper-proof and temperature protection

• Electronic short-circuit switch-off

• Soft start

• Dim function with digital phase dimmer

W ELECTRONIC TRANSFORMERS

re_trafogf.eps

re_trafo2.eps re_trafo1.eps

XC DESCRIPTION DIM. (WxHxD) PU TYPE ORDER NO.

ICE 60 PFS, 10 - 60 VA 39x145x28 1 RN 1602 YY160200—

ICE 105 PFS, 35 -105 VA 39x145x28 1 RN 1604 YY160400—

ICE 160 PFS, 100 - 160 VA 46x185x38 1 RN 1613 YY161300—

ICE 200 PFS, 100 -200 VA 46x185x38 1 RN 1614 YY161400—

ICE 250 PFS, 100 - 250 VA 50x225x39 1 RN 1532 YY153200—

re_trafo4.eps

KAPITEL_09_AK1 24.03.2005 17:46 Uhr Seite 451

Page 12: Main Catalogue 9 Transformerer Power Supply

ELECTRONIC TRANSFORMERS

452

DESCRIPTION DIM. (DxD) PU TYPE ORDER NO.

Zeus electronic starter, 4 - 65 W Ø21x35 1 p. 53999 YY539970—

W ELECTRONIC STARTER

re_start.eps

KAPITEL_09_AK1 24.03.2005 17:46 Uhr Seite 452