Copyright CONTRACT DRAWINGS FOR THE CONSTRUCTION OF MAIN WIND CONE REPLACEMENT PROJECT HALF MOON BAY AIRPORT LOCATION MAP NO ALTERATION PERMITTED HEREON EXCEPT AS PROVIDED UNDER THE APPROVED REVISION PROCESS TO THE BEST OF OUR KNOWLEDGE, INFORMATION AND BELIEF THE PLANS AND SPECIFICATIONS FOR THIS PROJECT ARE IN COMPLIANCE WITH THE BUILDING CODE OF THE STATE OF CALIFORNIA NOT TO SCALE C&S PROJECT # I16.002.002 FAA AIP PROJECT # 3-06-0097-015-2015 (DESIGN) SAN MATEO COUNTY STATE OF CALIFORNIA MARCH 2016 PROJECT LOCATION APPROVED _________________________________

Upload: duongkien

Post on 16-Jul-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Copyright ©

CONTRACT DRAWINGSFOR THE CONSTRUCTION OF

MAIN WIND CONE REPLACEMENT PROJECT

HALF MOON BAY AIRPORT

LOCATION MAP

NO ALTERATION PERMITTED HEREON EXCEPT AS PROVIDEDUNDER THE APPROVED REVISION PROCESS

TO THE BEST OF OUR KNOWLEDGE, INFORMATION AND BELIEF THEPLANS AND SPECIFICATIONS FOR THIS PROJECT ARE IN

COMPLIANCE WITH THE BUILDING CODE OF THE STATE OF CALIFORNIA

NOT TO SCALE

C&S PROJECT # I16.002.002

FAA AIP PROJECT # 3-06-0097-015-2015 (DESIGN)

SAN MATEO COUNTYSTATE OF CALIFORNIA

MARCH 2016

PROJECTLOCATION

APPROVED

_________________________________

PROPOSED TAXIWAY EDGE LIGHT

EXISTING CONTOUR LINE40

EXISTING FENCE LINE

EXISTING STORM DRAIN PIPE

EXISTING HEADWALL

EXISTING WATER LINE

EXISTING SANITARY SEWER LINE

EXISTING SANITARY SEWER MANHOLE

EX G

EXISTING GAS LINE

EXISTING OVERHEAD TELEPHONE LINE

EX T

OH/T

EXISTING UNDERGROUND ELECTRIC LINE

EXISTING OVERHEAD ELECTRIC LINE

OH/E

EXISTING UNDERGROUND TELEPHONE LINE

EXISTING LIGHT POLE

LP

UP

EXISTING UTILITY POLE

EXISTING CONCRETE DUCT MARKER

EXISTING CONCRETE CABLE MARKER

EXISTING CONCRETE SPLICE MARKER

D

C

S

EXISTING BOLLARD OR POST

EXISTING EDGE OF SHRUBS

EXISTING FLOW LINE

EXISTING BLOCK WALL

EXISTING RUNWAY OR TAXIWAY EDGE LIGHT

EXISTING AIRFIELD GUIDANCE SIGN

MW

EXISTING MONITORING WELL

EXISTING ELECTRICAL MARKER

EXISTING ELECTRICAL MANHOLE

EMH

EXISTING PULLBOX

PB

EXISTING DUCT BANK

EXISTING AIRFIELD LIGHTING CABLE IN TRENCH

EXISTING TRANSFORMER

EXISTING WIND CONE

EXISTING LIGHTED WIND CONE

EXISTING SURVEY CONTROL POINT

EXISTING AVIATION EASEMENT BOUNDARY

EXISTING DOUBLE SWING GATE

EXISTING CANTILEVER GATE

RUNWAY/TAXIWAY CENTERLINE

EXISTING AIRPORT PROPERTY LINE

EXISTING GUY WIRE AND ANCHOR

EXISTING ROAD

EXISTING AIRFIELD LIGHTING CABLE IN TRENCH

EXISTING TAXIWAY EDGE LIGHT

ABANDON IN PLACE

EXISTING POWER POLE

A

FLAGPERSON LOCATION

BARRICADE LOCATION WITH WORK

WORK AREA LIMITS / STAGING AREAS

APPROX. - APPROXIMATE

ASPH. - ASPHALT

BC - BEGIN CURVE

BLDG. - BUILDING

CIP - CAST IRON PIPE

CONC. - CONCRETE

CSP - CORRUGATED STEEL PIPE

DIA. - DIAMETER

ELEV. - ELEVATION

FND. - FOUNDATION

LT - LEFT

LP - LOW POINT

MAX. - MAXIMUM

MIN. - MINIMUM

MISC. - MISCELLANEOUS

NA - NOT APPLICABLE

OFA - OBJECT FREE AREA

PAV'T. - PAVEMENT

PC - POINT OF CURVATURE

PT- POINT OF TANGENCY

PVI - POINT OF VERTICAL INTERSECTION

PVC - POINT OF CURVATURE (VERTICAL CURVE)

PVC - POLYVINYL CHLORIDE PIPE

PVT - POINT OF TANGENCY (VERTICAL CURVE)

R - RADIUS

RCP - REINFORCED CONCRETE PIPE

RSA - RUNWAY SAFETY AREA

ROW - RIGHT OF WAY

RPZ - RUNWAY PROTECTION ZONE

RT - RIGHT

RW - RUNWAY

SHDR. - SHOULDER

SICPP - SMOOTH INTERIOR CORRUGATED

POLYETHYLENE PIPE

STA. - STATION

TOFA - TAXIWAY OBJECT FREE AREA

TSA - TAXIWAY SAFETY AREA

TW - TOP OF WALL

TYP. - TYPICAL

PI - POINT OF INTERSECTION

ABAN. - ABANDONED

CMP - CORRUGATED METAL PIPE

UD - UNDERDRAIN

PCC - PORTLAND CEMENT CONCRETE

PAVEMENT

BM - BENCH MARK

EC - END OF CURVE

FS - FINISH SURFACE

EOP - EDGE OF PAVEMENT

FF - FINISH FLOOR

GB - GRADE BREAK

W

EXISTING SANITARY SEWER CLEANOUT

EX E

EX SS

EX W

HAF 3

E

EXISTING DOMESTIC WATER METER

FG - FINISH GRADE

CMPA - CORRUGATED ARCHED METAL PIPE

FL - FLOW LINE

IE - INVERT ELEVATION

AST - ABOVE GROUND STORAGE TANK

TC - TOP OF CURB

TD - TOP OF DIKE

TF - TOP OF FOOTING

HP - HIGH POINT

ROFA - RUNWAY OBJECT FREE AREA

O.C. - ON CENTER

AREA DESIGNATION

BC-1

TP-1

TEST BORING LOCATION

TEST PIT LOCATION

EXISTING TAXIWAY EDGE LIGHT TO REMAIN

EXISTING AIRFIELD GUIDANCE SIGN

EXISTING RUNWAY OBSTACLE FREE ZONE

EXISTING RUNWAY SAFETY AREA

EXISTING RUNWAY OBJECT FREE AREA

ROFA

ROFZ

RSA

EXISTING POWER POLE

8950 Cal Center Drive

Suite 112

Sacramento, California 95826

Phone: 916-364-1470

www.cscos.com

C&S Engineers, Inc.

PROPOSED TRANSFORMER

AMPS - AMPERES

AWG - AMERICAN WIRE GAUGE

BFG - BELOW FINISHED GRADE

PROPOSED AIRFIELD LIGHTING CABLE IN

CONDUIT. "WC/I" DENOTES ONE #8 AWG, 600V,

I/C AIRFIELD LIGHTING CABLE IN EXISTING 2"

PVC CONDUIT (REMOVE EXISTING CABLE AND

PROVIDE THIS CABLE).

PROPOSED LIGHTED WIND CONE. ALL WIND CONE

MATERIALS SHALL BE RESISTANT TO CORROSION

AND RUST

TWY - TAXIWAY

SHEET NO. SHEET REFERENCE NO. TITLE

1 G-001 TITLE SHEET

2 G-002 SHEET INDEX, SURVEY CONTROL AND LEGEND

3 G-003 MAIN WIND CONE GENERAL NOTES

4 G-101 WIND CONE GENERAL PLAN

5 G-102 CONSTRUCTION SAFETY PHASING PLAN

6 G-103 MISCELLANEOUS DETAILS

7 CG-101 WIND CONE REPLACEMENT AND EROSION CONTROL PLAN

8 CG-501 WIND CONE DETAILS

WC/1

WC/1 - (SEE LEGEND ABOVE)

PROPOSED DIRECTION OF

CONSTRUCTION TRAFFIC

HORIZONTAL DATUM:

CALIFORNIA COORDINATE SYSTEM, ZONE 3

NORTH AMERICAN DATUM OF 1983 (NAD83), EPOCH 2005.69

VERTICAL DATUM:

NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88)

PROJECT CONTROL:

HAF 3 HAF 8 HAF 9

N: 2016698.56 N: 2016025.82 N: 2017650.02

E: 5982244.66 E: 5981499.90 E: 5979771.41

ELEV: ELEV: ELEV:

PROPOSED STABILIZED CONSTRUCTION

ENTRANCE

CND - CONDUIT

8950 Cal Center Drive

Suite 112

Sacramento, California 95826

Phone: 916-364-1470

www.cscos.com

C&S Engineers, Inc.

8950 Cal Center Drive

Suite 112

Sacramento, California 95826

Phone: 916-364-1470

www.cscos.com

C&S Engineers, Inc.

PROPOSED DIRECTION OF

CONSTRUCTION TRAFFIC

WORK AREA LIMITS / STAGING AREAS

LEGEND

8950 Cal Center Drive

Suite 112

Sacramento, California 95826

Phone: 916-364-1470

www.cscos.com

C&S Engineers, Inc.

NOTES:

1. CONTRACTOR SHALL COMPLY WITH REQUIREMENTS OF AC150/5370-2,

LATEST EDITION, AT ALL TIMES. SPECIAL ATTENTION IS DIRECTED TO

SECTION 80 OF THE FAA GENERAL PROVISIONS.

2. ALL FLAG PERSONS AND CONTRACTOR PERSONNEL SHALL ATTEND AN

AIRPORT SAFETY TRAINING MEETING CONDUCTED BY THE OWNER.

3. ALL CONSTRUCTION PERSONNEL AND EQUIPMENT OUTSIDE OF THE

DESIGNATED WORK AREAS SHALL BE IN RADIO CONTACT WITH AIRPORT

OPERATIONS OR BE ESCORTED. NO DELIVERY DRIVERS OR EQUIPMENT

SHALL ACCESS ACTIVE TAXIWAY PAVEMENT UNLESS PROPERLY

ESCORTED AS APPROVED BY THE OWNER.

4. A GATE GUARD SHALL BE STATIONED AT ANY ACCESS GATE BEING

ACTIVELY USED BY THE CONTRACTOR. ACCESS GATES SHALL BE

CLOSED AND LOCKED WHEN NOT IN USE AND WHILE NOT MANNED BY

GATE GUARD.

8950 Cal Center Drive

Suite 112

Sacramento, California 95826

Phone: 916-364-1470

www.cscos.com

C&S Engineers, Inc.

FLOW

12" MIN.

TRENCH DETAIL

8' MAXIMUM SPACING WITH

6' MAXIMUM SPACING WITHOUT

WIRE SUPPORT FENCE

WIRE SUPPORT FENCE

WOOD POST

WOOD POST

FLOW

18"

ISOMETRIC VIEW

NOTES:

1. SILT FENCE SHALL BE PLACED ON SLOPE CONTOURS TO MAXIMIZE PONDING EFFICIENCY.

2. INSPECT AND REPAIR FENCE AFTER EACH STORM EVENT AND REMOVE SEDIMENT WHEN NECESSARY.

9" (228mm) MAXIMUM RECOMMENDED STORAGE HEIGHT.

3. REMOVED SEDIMENT SHALL BE DEPOSITED TO AN AREA THAT WILL NOT CONTRIBUTE SEDIMENT

OFF-SITE AND CAN BE PERMANENTLY STABILIZED.

4. WHEN TWO SECTIONS OF SILT FENCE FABRIC ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY

6" AND FOLDED.

ATTACH FILTER FABRIC

SECURELY TO UPSTREAM

SIDE OF POST

EXTRA STRENGTH FILTER FABRIC

NEEDED WITHOUT WIRE MESH SUPPORT

4"x6" (102 X 152mm)

TRENCH WITH COMPACTED BACKFILL

FURNISH AND INSTALL PROVIDE NEW PRIMARY WIND CONE AND

SUPPORT STRUCTURE. REFER TO SHEET CG-501 FOR DETAILS

REMOVE AND DISPOSE OF EXISTING

PRIMARY WIND CONE ASSEMBLY, CABLE,

FOUNDATION, AND OTHER INCIDENTALS

AND DISPOSE OFF-SITE

CIRCULATORY SEGMENTED CIRCLE CONCRETE TO

REMAIN, PROTECT IN PLACE

REMOVE EXISTING CABLE FROM EXISTING CONDUIT AND

REPLACE WITH NEW CABLE, REFER TO DETAILS ON CG-501.

CONDUIT IS EXISTING TO REMAIN. VERIFY ALL EXISTING

CONDUIT PROPOSED FOR USE IS CLEAR, OPEN, AND FREE

OF DAMAGE. NOTIFY ENGINEER OF ANY BLOCKAGE OR

DAMAGE IN EXISTING CONDUIT, AND REPLACE DAMAGED

CONDUIT SEGMENT WITH NEW 2" SCHEDULE 40 PVC

CONDUIT. THIS WORK IS PAID FOR UNDER ITEM L-110.

CONNECT NEW CABLE TO EXISTING WIND CONE STEP-UP

TRANSFORMER IN ELECTRICAL VAULT. REFER TO A1/CG-101

AND C1/CG-501.

CLEAR AND GRUB ALL VEGETATION AND ORGANIC MATERIAL

A MINIMUM OF 5' WIDTH ALONG LENGTH OF CONDUIT TO BE

REMOVED. DISPOSE OF ALL REMOVED MATERIAL OFF-SITE.

CLEAR AND GRUB ALL VEGETATION AND ORGANIC MATERIAL

AND DISPOSE OFF-SITE

8950 Cal Center Drive

Suite 112

Sacramento, California 95826

Phone: 916-364-1470

www.cscos.com

C&S Engineers, Inc.

INSTALL SILT FENCE PER DETAIL B1/G-103

PROPOSED LIGHTED WIND CONE

FURNISH AND INSTALL

TWO #12 AWG AND

ONE #12 AWG

GROUND IN 3/4"

CONDUIT

FURNISH AND INSTALL

1 KVA 600V- 120/240V

TRANSFORMER

FURNISH AND INSTALL

TWO #8 AWG 600V 1/C

AIRFIELD LIGHTING

CABLES IN 2" CONDUIT

FURNISH AND INSTALL

600V, 30A, 2-POLE

DISCONNECT SWITCH

FUSED AT 15 AMPS

EXISTING

PULL BOX

TWO #8 AWG 600V 1/C AIRFIELD

LIGHTING CABLES IN EXISTING

CONDUIT (REFER TO AIRFIELD

LIGHTING PLANS)

EXISTING

VAULT

EXISTING WIND CONE

STEP-UP TRANSFORMER

TO REMAIN

TO EXISTING BRANCH

CIRCUIT PANEL

EXISTING BRANCH

CIRCUIT TO REMAIN

PROVIDE TWO #8 AWG, 600V, 1/C AIRFIELD LIGHTING

CABLES IN 2" SCHEDULE 40 PVC CONDUIT. COORDINATE

BURIAL DEPTH IN FIELD WITH EXISTING PULL BOX.

PROVIDE SINGLE PHASE 1KVA 600V -

120/240V STEP-DOWN TRANSFORMER

IN NEMA-3R 304 STAINLESS STEEL

ENCLOSURE. BASIS OF DESIGN SHALL

BE CROUSE-HINDS SG0G11P01P OR

APPROVED EQUAL. PROVIDE 600V,

2-POLE, 30A DISCONNECT SWITCH

FUSED AT 15A ADJACENT TO

TRANSFORMER. REFER TO C1, THIS

SHEET FOR WIRING DIAGRAM.

BASIS OF DESIGN FOR PROPOSED WIND CONE

SHALL BE HALI-BRITE L-807-S2-IN-120-5

INTERNALLY LIGHTED LED OR APPROVED EQUAL.

PROVIDE ZINC-RICH PRIMER AND POWDER

COATING FOR WIND CONE SUPPORT STRUCTURE

AND FRAMEWORK, FOR CORROSION

RESISTANCE. BASIS OF DESIGN SHALL BE TIGER

SHIELD SERIES 69 OR APPROVED EQUAL.

PROVIDE 120V LED OBSTRUCTION LIGHT,

CROUSE-HINDS RTLSF/120 OR APPROVED EQUAL.

PROVIDE TWO #12 AWG TYPE THHN/THWN

CABLE AND ONE #12 AWG GROUND

CONDUCTOR IN 3/4" SCHEDULE 40 PVC

CONDUIT. DIRECT BURY AT 24" BFG TO

TOP OF CONDUIT.

CIRCULATORY CONCRETE TO

REMAIN, PROTECT IN PLACE

PROVIDE TWO #8 AWG, 600V, 1/C

AIRFIELD LIGHTING CABLES IN

EXISTING CONDUITS. REFER TO

A1/CG-101 FOR CONTINUATION.

3'-0"

OR

A

S R

EQ

UIR

ED

BY

M

AN

UF

AC

TU

RE

R

2'-0"

1'-0"

M

IN

.

2'-6" x 2'-6"

1'-6"

(T

YP

.)

2' TO 5'

1'-0"

CONNECT NEW #8 AWG

CABLE TO EXISTING

STEP-UP TRANSFORMER

8950 Cal Center Drive

Suite 112

Sacramento, California 95826

Phone: 916-364-1470

www.cscos.com

C&S Engineers, Inc.