malema excess flow valves confidential 1. use & applications malema excess flow valves are used...
TRANSCRIPT
Malema Excess Flow Valves
Confidential
1
Use & Applications
Malema Excess flow valves are used as safety devises to shut-off the flow of hazardous and expensive fluids in the event of rupture caused in downstream piping
Applications: Various fluids used in Oil & Gas, Petrochemical industries, Chemical industries
Confidential
2
M-XF Applications- Transfer lines in the petroleum and chemical industries
Confidential
3
LPG TRUCK/TANKER LOADING STATIONS
Another most common M-XF application
Confidential
4
Design
Confidential
5
How It Works
• Poppet position is set for a given flow rate by adjusting the set screw.
•During normal operation poppet is open thereby allowing flow through seat.
•During the excess flow condition the poppet is closed due to suction effect and the fluid is held back.
Confidential
6
Technical Data
Confidential
7
Available Sizes: ¾” to 12” Optional up to 20”
Pressure Ratings: ANSI #150, 300, 600, 900, 1500Optional : Other standards and ratings
Material of Construction: Carbon Steel, SS 304, 316, 316LOptional: Hastalloy and Monel
Shut off Range: Water: 0.1 to 2500 US GPMAir: 0.5 to 40000 SCFM
Applicable Standards: Face to Face dimension as per ASME/ANSI B16.10 Flange Dimension as per ASME/AMSI B16.5Hydro test as per API 598 .
Confidential
8
Testing and Calibration:
Testing: Hydro test
Calibration: If factory setting is required the valve
will be calibrated using water flow
rate equivalent to the application
fluid’s shut of flow rate.
Optional testing: Liquid dye penetration
Positive Material Identification
Hydro test as per API 598
Radiography
Sizing & Selection
Confidential
9
A Typical Installation:By-pass Line Configuration
A reset valve is installed on a by-pass line
To Reset a closed excess flow valve:
•Close the isolation valve and
•Open valve in bypass line to equalize pressure in the main line
Confidential
10
Malema Excess Flow Valve with built-in Reset
Reset mechanism is integrated to the excess flow valve
Eliminates additional piping and hardware required upstream of the valve
Reduces the cost installation
Confidential
11
Additional Accessories Excess valve OPEN/CLOSE indication can be
provided with a use of differential pressure gauge.
Remote OPEN/CLOSE contact signal can be provided with a use of differential pressure switch. Useful for integrating with safety shutdown systems and other control strategies.
A combination of built-in reset with above features is also available as an option.
Confidential
12
Confidential
13
Local On/Off Indication
Local On/Off Indication and integral bypass reset valve
Benefits Field Adjustable Set Point
– Adjustments can be made without removing the valve Easier Reset Variety of pressure ratings Variety of wetted parts to suit the application Preventive Maintenance Performed in Line
– Valve does not have to be removed– Reduces down time
2 Year Warranty Lower Cost of Ownership
Confidential
14
Excess Flow Valve model M-VF
- for low flow, high/low pressure sample lines, gas supply lines and analyzer panels
Confidential
15
Standard Excess Flow Valve
Excess Flow Valve with integral reset option
Operation
Confidential
16
As the fluid (liquid or gas) enters the valve, the pressure differential across the piston creates a venturi effect, accelerating the flow through the valve.
At a preset flow rate, when the differential exceeds the magnetic attraction between the piston magnet and the adjusting screw magnet, the piston travels instantaneously over towards the output port, thereby shutting off the flow.
When the pressure is equalized between both sides of the valve, the piston automatically returns to its previously adjusted flow set-point.
The shut off set point is field adjustable and this is achieved by turning the adjusting screw.
Various Options: Bleed to Atmosphere
Manual Rest option for non Hazardous medium
Confidential
17
Excess Flow Valve with Intrinsic Reset Option
Suitable for hazardous fluid applications where even a small amount leak to the atmosphere during reset is not permissible.
Confidential
18
Bleed to Sample container
Suitable for costly and hazardous liquids where bleed during reset is directed towards a customer provided container. The integral bleed valve helps achieves this function.
Confidential
19
M-VF FOR GAS CHROMOTOGRAPHS
M-VF can be used in the hydrogen carrier lines which helps hydrogen leaksInto atmosphere in the event of accidental line rupture.
Confidential
20
Customer Reference List ADM BASF Corporation Bechtel BMW CITGO Petroleum Corporation Caterpillar Dairen Chemical Earthsafe Systems, Inc. Florida Gas Transmission General Mills Operation, Inc. Georgia-Pacific General Electric
• Glaco Midwest, Inc.
• Hoerbiger Corporation of America
• Hoidale Co, Inc.
• Hyundai Heavy Industries
• Hunt Refining Company
• JGC Corporation
• Lanza, Inc.
• Lyondell Chemical Company
• Roberts Oxygen Company
• Sherwin Williams
• Tampa Electric
• Trigon Engineering
Confidential
21
Confidential
22
Our Commitment A Safety product is bought on trust that the
customer has in the product and the company that stands behind it.
Malema’s two decade of experience in manufacturing excess flow valves delivers you a trusted product.
Our engineers will be available to install the first units to train your engineers .
Confidential