Managing The Infrastructure Of Data Centers
David CuthbertsonSquare Mile Systems Ltd
![Page 2: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/2.jpg)
Square Mile Background• Develop toolsets, training and
techniques for operational management of complex IT infrastructure
• Focus areas– Data center management– Connectivity management– System change impact analysis – Documentation techniques– Infrastructure visualisation
• All technologies!
Business ProcessesDepartmental, Company
ServicesEnd user, infrastructure, supplier
ApplicationsPC, server, mainframe, SOA
Fixed Infrastructure(Cabling, Power, Cabinets, Buildings)
Hardware InfrastructureNetwork, Servers, UPS, Storage, Other
Virtual InfrastructureNetwork, Servers, Storage, DBMS
Data Center Infrastructure
![Page 3: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/3.jpg)
Seminar overview• Understand management issues to aid
selection of technology and techniques• Communicating “best practice”• Develop your own perspectives and learn
from others• Exercises covering typical DC issues• Have a few laughs on the way• Only two uses of the word “green”
![Page 4: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/4.jpg)
Common Management Issues• Data Centre is often not visible, nor are the staff• “If it’s not broke” attitude isn’t good,
infrastructure risks need to be managed• IT groups are often task and project orientated,
less focus on operational issues• Getting funds allocated for improving
management techniques is difficult• Skills sets need to evolve with technology and
organisation control requirements
![Page 5: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/5.jpg)
Defining “Management”• Planning what needs to be done to
achieve a particular result• Organising and directing resources.• Controlling and making adjustments as
needed• Motivating all those involved.
![Page 6: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/6.jpg)
Management Maturity
Reactive Repeatable Defined Managed Optimised1 2 3 4 5
Process open to external review and
updated regularly
Process checked and reviewed for
gaps
Individualapproach
Some process, often informal
Process documented
and explained
Where might you be if youa) Didn’t label patch cablesb) Labelled patch cables consistently?c) Audited records against patching documentation?
![Page 7: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/7.jpg)
Why Improve DC Management?1. New technology demands
– Cooling, power, cabling, weight2. Save on capital and operational costs
– Optimise existing facilities– Reduce power and other costs
3. Less tolerance of outages and disruption4. Speed of change5. External need for evidence of control
![Page 8: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/8.jpg)
Changing Requirements
BEFORE AFTERNo. of Servers per cabinet 3-6 30-40Power Disipated per cab. 300-2000W 3kW - 25kWCurrent service to cabinet 16A 2x32 A or 3 phaseTypes of Equipment Servers Blade Servers
Monitor Power Distribution UnitsKVMs MidSpan Boxes
Power Strips Disk Arrays (Storage)UPS Smart Power Strips
Regular Power StripsNetwork types 100M 1G, 10G, SANNo. of Cables Power 1 or 2 2 to 6(per server) Network 1 or 2 5 to 10
Cabinet Total 20-30 300 - 400
![Page 9: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/9.jpg)
New Technology ChallengesSun Blade 8000 Blade Chassis
– 4 Power supplies (N+1) 9kW– 3 chassis per rack – 27kW?
HP C7000 Blade Chassis– Up to 6 Power Supplies 13kW– 4 chassis per rack
Cisco Nexus 7000 Data Center Switch– 3 Power Supplies 12kW– Up to 384 ports
And in the next few weeks?
![Page 10: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/10.jpg)
Starting Well1. Specify and build the infrastructure using
a standards based approach1. TIA942 data centre design2. Other standards TIA, EN, etc.
2. Test installation for conformance to requirements
3. Handover of documentation, skills transfer and operational procedures to customer
![Page 11: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/11.jpg)
So How Did This Happen?
![Page 12: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/12.jpg)
Different Working Practices
![Page 13: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/13.jpg)
Exercise 1 Cable ManagementBoth are cabling implementations using
different management styles
1. Explain why the cabinet on the left is preferred
2. Explain what you may have to do to keep the left cabinet maintained in the same style
![Page 14: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/14.jpg)
Exercise 1 Review
Risk Organisation
Speed Process
Cost Technology
![Page 15: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/15.jpg)
So…You may understand, but you can’t assume
others do
Professionally designed infrastructure will be compromised without professional management practices!
![Page 16: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/16.jpg)
Defining Best Practices• You could define your own best practice
– Authority– Experience– Technically qualified– Best communicator– Management information
• Or you could adopt a framework– Quicker path to end result with less opinions
![Page 17: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/17.jpg)
Management FrameworksITIL / ISO20000Service Management
BS25999 Business Continuity
ISO27001 Information Security
CoBit IT GovernancePlan
Act
Check
Do
All have a continuous process
But no equivalent for data centermanagement!
![Page 18: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/18.jpg)
ISO20000/ITIL V2Service Delivery Processes
Security Management
Service Continuity & Availability Management
Service Level Management
Service Reporting
Capacity Management
Financial Management
Release ProcessesRelease Management
Resolution Processes
Incident Management
Problem Management
BusinessRelationship Management
Supplier Management
Control ProcessesConfiguration Management
Change Management Relationship Processes
![Page 19: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/19.jpg)
Why have a framework?• Common understanding of complex issues
– Terms, Processes, Roles– Measurement, identification of gaps– Communication– Training for individuals and teams
• Focus provided– Easier adoption of industry techniques– Overcomes internal reluctance to change
![Page 20: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/20.jpg)
Example of Best PracticeProcuring a new server
– Policies - sign off, payment– Ordering process – life cycle– Purchase orders – common reference– Roles and responsibilities – specify, order and
approve
![Page 21: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/21.jpg)
Best Practice in Data Centers
• Design– TIA942 standard, Uptime Institute,
manufacturer guidelines• Build and Install
– Standards and regulations TIA, etc.• Operate
– ???– EU Code of Conduct for Data Centers –New!
![Page 22: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/22.jpg)
Different Power Views
LINK 10/100FEATURE
LANSERIAL
CURRENT���������������
ON = I OFF = U
BLINK = REMOTE
OUTLET #I/U TOGGLE
RESERVED
STATUS 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
100-240V
~
50~60Hz
1.2A
KVM
Servers
What should the working limit be for the power strip?
16A feed 16A feed
LINK 10/100FEATURE
LANSERIAL
CURRENT�������������
ON = I OFF = U
BLINK = REMOTE
OUTLET #I/U TOGGLE
��
![Page 23: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/23.jpg)
Exercise 2 Power CalculationsWhat types of equipment power/current
rating should be known and used when assessing and planning changes?
![Page 24: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/24.jpg)
So….• Monitoring tools are useful, but they only
tell you what they see• For managing power infrastructure we
may need multiple values– Manufacturer power rating– Derated power – often 60% of manufacturer– Design power– Actual power
![Page 25: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/25.jpg)
Data Center Management• No public framework exists for data
centers – yet…• In other areas it is easier
– ITIL, ISO20000 Service Management– ISO27001 Information Security– Cobit IT Controls– Prince 2 Projects– ISO9000/6 Sigma Quality
![Page 26: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/26.jpg)
Exercise 3- Wasted CostsGive an example where because of lack of
knowledge or understanding, unplanned or unnecessary costs were incurred
![Page 27: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/27.jpg)
Exercise 4 Server Provisioning• You have received a request to move 10
existing servers into a data centre.
• What tasks might have to be done to fulfil this request?
![Page 28: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/28.jpg)
Exercise 4 Server Provisioning
Assess
Plan
Implement
Test
Completion
Concentrate on these two and
the tasks appropriate to
each
It is important to identify specific tasks and whether they should be in the assessment or detailed planning phases
![Page 29: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/29.jpg)
Provisioning ReviewWhat did we learn?
Types of information required at each stageTracking and controlCommunication needsComplexity of infrastructure changes
![Page 30: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/30.jpg)
Managing Existing Data Centers• Environment limits• Information sets - formal and informal • Working practices - formal and informal• Roles / responsibilities• Current issues• Establish priorities
![Page 31: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/31.jpg)
PDU
Power Strips
Power Strips
Power Strips
100A 100A 100A
Incoming feeds
UPS
3 Phase
32 & 16 Amp Sockets
Remote Controlled Power Strips
10A 16A Ethernet
Circuit Breakers
32A 16A16A
Typical Power Distribution
![Page 32: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/32.jpg)
Exercise 5 – Power Trips• Your first objective as the new data centre
manager is to prevent circuit breakers tripping unexpectedly due to loading issues.
• What would you do and in what order?– One day– One week– One month
![Page 33: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/33.jpg)
Establishing a Baseline• Know your environment design limits• Understand the “gaps”
– Roles– Knowledge– Practices
• Decide on priorities and actions
![Page 34: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/34.jpg)
Baseline – troubleshooting1. Establish control2. Assess information provided3. Create plan of action4. Gather more information if required5. Stabilise6. Change process7. Optimise
![Page 35: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/35.jpg)
Establish Design Limits• Room• Architectural and Structural - Weight• Mechanical - Cooling, fire detection
/suppression• Electrical – Power• Cabling standards and limitations
![Page 36: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/36.jpg)
Controlling the Environment• Known design limits• A baseline of the current estate• Change approval process • Forward planning for capacity• Regular reviews against limits• Maintenance practices
– Routine– Verification on process adoption
![Page 37: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/37.jpg)
Is this Rack Full?01-07 - FRONT
A005 A006 A007 A008A001 A002 A003 A004 A009 A010 A011 A012 A013 A014 A015 A016 A017 A018 A019 A020 A021 A022 A023 A024 PP01-07-01PWR01-07-APWR01-07-B
PROLIANT
DRIVE SURFACESMAY BE HOTALLOW TO COOLBEFORE TOUCHING
WARNING:
SVR-BHAM-010701
mic r os ys t em s®
1120
UK_BIRM_UX05
mic r os ys t em s®
1120
UK_BIRM_UX06
mic r os ys t em s®
1120
UK_BIRM_UX07
mic r os ys t em s®
1120
UK_BIRM_UX08
Cable Mgmt 01-07-04
It depends on SpaceWeightPowerCoolingConnectivity
![Page 38: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/38.jpg)
Data Center Documentation• It’s common sense that you should know
what is in your data centre and how it is configured
• But achieving this is not so easy
• Why is it so difficult?
![Page 39: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/39.jpg)
Data Center Documentation• Commissioning documentation
– Project plans and designs– Testing results– Initial systems provision – BMS
• Operational documentation– Various sets for ongoing management
![Page 40: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/40.jpg)
Exercise 6 – Data Center RecordsThe 10 servers have been
successfully installed in the data center.
What records or systems would you expect to have been updated or modified directly as a result of the additional servers?
Data Center
A to Z
![Page 41: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/41.jpg)
Different Teams, Different Focus
Fixed Infrastructure(Cabling, Power, Racks, Rooms, Buildings)
Hardware InfrastructurePCs, Network, Servers, UPS, Storage, Other
Virtual InfrastructurePCs, Network, Servers, Storage, DBMS
ApplicationsPC, server, mainframe, SOA
ServicesEnd user, infrastructure, supplier
Business ProcessesDepartmental, Company
ServiceManagement
DataCentre
NetworksLAN/SAN
Applications
Mid-range Servers
Systems
DesktopsIMAC
![Page 42: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/42.jpg)
Different views of a server
Floor Plan
Rack Position
Service impact
Power Supply
Network Connections
BLADE_BIRM01
UK_BIR
M01_BLAD
E-01
UK_BIR
M01_BLAD
E-02
UK_BIR
M01_BLAD
E-03
UK_BIR
M01_BLAD
E-04
BLADE-BIR
M01.BLAD
E-SW1
BLADE-BIR
M01.BLAD
E-SW2
UK_BIR
M01_BLAD
E-05
UK
_BIRM
01_BLADE-09
UK
_BIRM
01_BLADE-10
UK
_BIRM
01_BLADE-12
H/W Build
![Page 43: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/43.jpg)
Recommended Information Sets• Space • Environment (power, cooling)• Connectivity (power, networks)• Asset and Inventory controls • Device management• Service management
![Page 44: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/44.jpg)
Space Management• Space management systems• Floor layouts and plans• Rack layouts• Floor loading• Cabinet functions (customer, comms,
servers etc.)
![Page 45: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/45.jpg)
Environment Management• Building management systems
– Fire, cooling, temperature, power, humidity• Power management systems
– PDU, UPS, power strips• Access controls• Power distribution diagrams and lists• Current and projected power / cooling
– Hot/cold aisle views
![Page 46: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/46.jpg)
Connectivity Management
TIA 942
Cabling architecture involving rooms, zones,
cabinets, paths
![Page 47: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/47.jpg)
Where to Start? Structured cabling only
KVM ArchitectureLAN diagrams
Storage diagramsPatching spreadsheetsInventory list
KVM WAN diagrams Point to Point Cabling
Building wiring diagramsAsset listLegacy systems
Backbone switches
IIS ArchitecturePower distributionEdge switchesPower architecture
Blade switchesComputer room layoutPDUs
Circuit breakers Labelling standards SAN Architecture
PABX port mapping Power strip connectionsLAN Architecture
![Page 48: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/48.jpg)
Use the Boston Matrix MethodIdentifying Focus for a Power Baseline
PDUCircuit BreakersUPSMainframeStorageFirewalls
Amount of Connections
Impa
ct o
f Pow
er O
utag
eLo
w
H
igh
Low High
Power StripsServersNetworks
ModemsManagement Tools
LightingOffice outlets
![Page 49: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/49.jpg)
Exercise 7 – LAN ConnectivityIdentifying Focus for LAN Baseline Project
4
2
Amount of ConnectionsLow High
3
1
1. Backbone cabling2. Cabinet/Zone cabling3. Floor boxes4. Servers5. Core Switches6. Edge Switches7. Wireless Access Points8. Routers9. Firewalls10.SANs11.Power strips12.KVMs13. IP phones14.Desktops
Use
r Im
pact
of D
isco
nnec
tLo
w
H
igh
![Page 50: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/50.jpg)
To Manage Connectivity1. Document the fixed infrastructure first
– Backbone, power, vertical2. The active components
– Switches, servers, SAN etc.3. Finally the connectivity
– Local, path and endpoints
![Page 51: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/51.jpg)
Defining the Level of Detail1. Local patch?
PatchPanel
2. End to End path?
PatchPanel
PatchPanel
3. All devicesconnected to theswitch?
PatchPanel
PatchPanel
![Page 52: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/52.jpg)
Asset Controls• Lists of all devices and assets• Their current status and location• Previous history and audit trail• Often combined with maintenance and
procurement data• Auto-discovery can help, but often limited
in value in data centers.
![Page 53: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/53.jpg)
Device or Element Management• Network, server, storage monitoring• Configuration systems• Automated deployment / provisioning• Network and other architecture diagrams• Automated discovery and scanning• Backup and failover
![Page 54: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/54.jpg)
Service & Risk Management• Help or service desk system• Project control or workflow system• Services maps
– Devices mapped to critical services• Service monitoring tools• Billing and charging• Recovery planning and testing
![Page 55: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/55.jpg)
DC Capacity Management• Demand management to capture requests• Existing + allocated demand recorded• Capacity Plan and “database”• Reporting and trending on
– Space– Power– Cooling– Network, SAN Port availability– Resource (staff)
• “Green” reporting
![Page 56: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/56.jpg)
Charging and FundingDifferent perspectives
SpacePowerCoolingNetwork Ports usedShared Infrastructure Costs and Support Hardware Maintenance Costs and Support Operations Costs and Support
![Page 57: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/57.jpg)
Exercise 8 - Reducing Costs• Without buying new technology, or
changing staffing, you are targeted with improving the cost base of the data center.
• What management initiatives can you undertake that will reduce direct costs?– You have your team, they need direction
![Page 58: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/58.jpg)
Meeting the Needs of 3rd Parties• SOX, PCI, FSA, auditors, etc.• Building & planning requirements• Employment and buildings legislation
– Disability– Health and safety– Electricity at work– Carbon tax– And others
• Insurance
What would be sufficient evidence to satisfy them of your controls in most cases?
![Page 59: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/59.jpg)
Energy Issues• EU Regulations already in place
– Energy performance of buildings– Energy using product directive (colour codes on white goods)– WEEE and RoHS directives
• US Green Building Council LEED Program– Leadership in Environmental Design
• The Green Grid programme• EU Code of Conduct for Data Centres
– Completed 1Q2009– Covers all data center, server and equipment rooms
• UK draft climate change bill• Carbon trading
![Page 60: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/60.jpg)
EU Code of Conduct• Aim is to inform and stimulate data center
owners to reduce energy consumption– Understand energy usage– Raise awareness– Communicate practices which will reduce
energy consumption• Voluntary at present• Available at http://dcsg.bcs.org
![Page 61: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/61.jpg)
EU Code of Conduct• Measurements against best practices for
– Cooling– Power equipment– Other data center equipment– Data center utilisation, management & planning– IT equipment and services– Energy monitoring
• Temperature and humidity requirements for equipment– Suggested limits are 5ºC- 40ºC
![Page 62: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/62.jpg)
EU Code of Conduct• Additional best practices document is
useful for all as it covers– Design– Operate– New equipment and retrofit issues– IT equipment selection– Power, cooling, storage– Monitoring and reporting
![Page 63: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/63.jpg)
Managing Risk
What presents the greatest risk?
![Page 64: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/64.jpg)
Evidence of Conformance• Policies covering control, security etc.• Evidence of processes that support the
policies– Change records– Build and test records– Written material or email trails– Communications– Incident reviews– Access lists
![Page 65: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/65.jpg)
Access and Security Practices• Secure access is a common feature in data centres• Access control will depend on organisational issues
– Building access– Room access– Cabinet, equipment– Layering - multiple needs to authenticate access
• Many types– What you have Card or token– What you know Pass code, keypad– Who you are Biometric (finger, eye)
• Use a standard framework (ISO27001, CoBit etc.)
![Page 66: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/66.jpg)
Security Impacts• Physical access will be more difficult
– Access requests and tracking• Changes will have to be logged at an
increased level of detail• Verification / audits will be more common
to meet auditor / customer needs• Without improving the infrastructure
documentation, changes will take longer
![Page 67: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/67.jpg)
Current IssuesSecurity of data on individual’s financial and
personal lives is becoming high profile. The data in the data center is valuable!
www.idtheftcenter.org
ITRC20090304-01NYPD Pension Fund 3/4/2009A civilian official of the NYPD’s pension fund has been charged with stealing the identities of 80,000 current and retired cops, sources said. He allegedly got into a secret backup-data warehouse on Staten Island last month and walked out with eight tapes packed with Social Security numbers, direct-deposit information for bank accounts, and other sensitive material.
Example
![Page 68: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/68.jpg)
Management Maturity
Reactive Repeatable Defined Managed Optimised1 2 3 4 5
Process open to external review and
updated regularly
Process checked and reviewed for
gaps
Individualapproach
Some process, often informal
Process documented
and explained
What will be different next year?
![Page 69: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/69.jpg)
Managing the Infrastructure• Planning what needs to be done to
achieve a particular result• Organising and directing resources.• Controlling and making adjustments as
needed• Motivating all those involved
![Page 70: Managing The Infrastructure Of Data Centers - Square Mile](https://reader031.vdocument.in/reader031/viewer/2022020704/61fb61132e268c58cd5d7905/html5/thumbnails/70.jpg)
Thank you for your attention
Questions or feedback?