marcus · marcus single phase control transformer marcus transformer ltd phone: 1-800-267-7376 fax:...

24
VA 100 Primary (Volts) 120 / 240 Secondary (Volts) 12 / 24 Input /Output Amps 0.83 , 0.42 / 8.33 , 4.17 Approvals 7HPSHUDWXUH 5LVH & ,QVXODWLRQ &ODVV % & Frequency 50 / 60Hz Polarity additive Noise level less than 40DB DESCRIPTION Type Open Winding Copper UL listed CE compliant CSA approved WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : MODEL MTB100A Notes: H1-H4 120 240 INTERCONNECT: H1-H3 AND H2-H4 H2-H3 VOLTS 12 24 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 CONNECT LINES TO : X1-X4 H1-H4 X1-X4 E A D B C 0.21 x 0.625 MOUNTING INCHES / MM WEIGHT SHIP HOLES B D C E 2.75 1.3 5.3 x 15.9 4.00 3.00 67.3 2.50 2.50 101.6 63.5 63.5 DIMENSIONS 2.65 76.2 A LBS / KG INCHES / MM VA 100 CONNECTION DIAGRAM H4 H1 X1 X3 X2 X4 H2 H3 0V 0V TECHNICAL DATA MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: [email protected]

Upload: others

Post on 23-Jan-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 120 / 240

Secondary (Volts) 12 / 24

Input /Output Amps 0.83 , 0.42 / 8.33 , 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100A

Notes:

H1-H4

120

240

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 2: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 120 / 240

Secondary (Volts) 120 / 240

Input /Output Amps 0.83 , 0.42 / 0.83 , 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100B

Notes:

H1-H4

120

240

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 3: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 208 / 416

Secondary (Volts) 12 / 24

Input /Output Amps 0.48 , 0.24 / 8.33 , 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100C

Notes:

H1-H4

208

416

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2

H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 4: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 208 / 416

Secondary (Volts) 120 / 240

Input /Output Amps 0.48 , 0.24 / 0.83 , 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100D

Notes:

H1-H4

208

416

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 5: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 240 / 480

Secondary (Volts) 120 / 240

Input /Output Amps 0.42 , 0.21 / 0.83 , 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100E

Notes:

H1-H4240

480

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2

H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 6: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 240 / 480

Secondary (Volts) 12 / 24

Input /Output Amps 0.42 , 0.21 / 8.33 , 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100F

Notes:

H1-H4240

480

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 7: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 277

Secondary (Volts) 120 / 240

Input /Output Amps 0.36 / 0.83 , 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100G

Notes:

H1-H2277

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

120/240 X2-X3 X1-X3-X4

CONNECTION DIAGRAM

H2

H1

X1 X2

0V

0V

X4X3

277 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 8: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 347 / 380

Secondary (Volts) 120 / 240

Input / Output Amps 0.29 , 0.26 / 0.83 , 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100H

Notes:

H1-H2347

380

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H3

X1-X4

Pos.

Volts

CONNECTION DIAGRAM

0V

H2

H3H1

X1X2X3

0V

347 380

X4

0V

H2 H3H1

Primary Tabs

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 9: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 600

Secondary (Volts) 12 / 24

Input /Output Amps 0.17 / 8.33 , 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100I

Notes:

H1-H2600

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

12/24 X2-X3 X1-X3-X4

CONNECTION DIAGRAM

H2

H1

X1 X2

0V

0V

X4X3

600 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 10: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 600

Secondary (Volts) 120 / 240

Input /Output Amps 0.17 / 0.83 , 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100J

Notes:

H1-H2600

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

120/240 X2-X3 X1-X3-X4

CONNECTION DIAGRAM

H2

H1

X1 X2

0V

0V

X4X3

600 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 11: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 347 / 380

Secondary (Volts) 12 / 24

Input / Output Amps 0.29 , 0.26 / 8.33 , 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100K

Notes:

H1-H2347

380

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H3

X1-X4

Pos.

Volts

CONNECTION DIAGRAM

0V

H2

H3H1

X1X2X3

0V

347 380

X4

0V

H2 H3H1

Primary Tabs

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 12: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 120

Secondary (Volts) 12

Input /Output Amps 0.83 / 8.33

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100M

Notes:

H1-H2120

CONNECT LINES TO :

VOLTS

X1-X212

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

120 V

12 V

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 13: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 120

Secondary (Volts) 24

Input /Output Amps 0.83 / 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100N

Notes:

H1-H2120

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

120 V

24 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 14: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 208

Secondary (Volts) 120

Input /Output Amps 0.48 / 0.83

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100O

Notes:

H1-H2208

CONNECT LINES TO :

VOLTS

X1-X2120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

208 V

120 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 15: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 240

Secondary (Volts) 24

Input /Output Amps 0.42 / 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100P

Notes:

H1-H2240

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

240 V

24 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 16: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 240

Secondary (Volts) 120

Input /Output Amps 0.42 / 0.83

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100Q

Notes:

H1-H2240

CONNECT LINES TO :

VOLTS

X1-X2120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

240 V

120 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 17: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 480

Secondary (Volts) 24

Input /Output Amps 0.21 / 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100R

Notes:

H1-H2480

CONNECT LINES TO :

VOLTS

X1-X224

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

480 V

24 V

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 18: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 480

Secondary (Volts) 120

Input /Output Amps 0.21 / 0.83

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100S

Notes:

H1-H2480

CONNECT LINES TO :

VOLTS

X1-X2120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

480 V

120 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 19: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 600

Secondary (Volts) 12

Input /Output Amps 0.17 / 8.33

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100T

Notes:

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X212

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

12 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 20: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 600

Secondary (Volts) 24

Input /Output Amps 0.17 / 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100U

Notes:

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

24 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 21: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 600

Secondary (Volts) 120

Input /Output Amps 0.17 / 0.83

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100V

Notes:

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X2120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

120 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 22: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 600

Secondary (Volts) 240

Input /Output Amps 0.17 / 0.42

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100W

Notes:

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X2240

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

240 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 23: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 120 / 240

Secondary (Volts) 16 / 32

Input /Output Amps 0.83 , 0.42 / 6.25 , 3.13

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100X

Notes:

H1-H4120

240

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

16

32

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

CONNECTION DIAGRAM

H4 H1

X1 X3

X2 X4

H2

H3

0V

0V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 24: MARCUS · MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 100 Primary (Volts) 120 Secondary

VA 100

Primary (Volts) 208

Secondary (Volts) 24

Input /Output Amps 0.48 / 4.17

Approvals

Temperature Rise 80°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Open

Winding Copper

UL listed

CE compliant

CSA approved

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

MODEL MTB100Y

Notes:

H1-H2208

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

208 V

24 V

E

A

D

B

C

0.21 x 0.625

MOUNTING

INCHES / MM

WEIGHT

SHIP

HOLES

B DC E

2.75

1.35.3 x 15.9

4.003.00

67.3

2.502.50

101.6 63.563.5

DIMENSIONS

2.65

76.2

A

LBS / KG

INCHES / MM

VA

100

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]