marine generators - smart energy shop performance extremely quiet water-cooled compact light power -...
TRANSCRIPT
High Performance
Extremely Quiet
Water-Cooled
Compact
Light
Power - wherever you are
Catamarans
Motorboats
Lifeboats
Commercial Vessels
Yachts
Houseboats
Marine Generators
� �
Fischer Panda GmbH manufactures compact and quiet diesel generators for marine and vehicle applications. These are sold in over sixty countries worldwide under the trade name “Fischer Panda.”The company, based in Paderborn-Germany, was originally founded in 1977 under the name Icemaster GmbH and renamed to Fischer Panda GmbH in �007.The water-cooled diesel generators from Fischer Panda are renowned worldwide for being innovative, reliable and extremely quiet. The product range includes over two hundred different generators and covers a performance range from �.5 kW to 100 kW.Fischer Panda Generators feature an effective water-cooling system and a lightweight compact construction. This ensures Fischer Panda generators are the No. 1 in Europe for mobile super-silent diesel generators. These highly-proven marine and vehicle generators supply power to on-board electrical systems, electric drives and complete mobile energy systems.
Panda Marine Generators
Since 1988, Fischer Panda has manufactured more than 18.000 marine generators with this technology. One of the reasons for the superior efficiency of Panda generators is the very effective cooling system, it ensures that the temperatures inside the sound insulation capsule remains within an acceptable range even in tropical conditions at the same time achieving the best possible sound insulation as free-flowing cooling air is not required.Dual-circuit cooling for generator and engine
Seawater with high-salt content and tropical temperatures increases the danger that metal can be affected by galvanic corrosion (Electrolysis).
Water-cooled windings
Dual-circuit cooling
Water-cooling for engine and generator
No appreciable warming of engine room
Performance stability through dual-circuit cooling
Stainless-steel sound-insulation capsule “MPL” for generators from 30 kW.
GFK Sound insulation capsule is standard for generators up to 25 kW.
Panda Marine generators up to �5 kW, are delivered with a GFK sound insulation capsule with “�D” sound insulation material as standard (optional: sound insulation material: “4DS”).
From �0 kW, the capsule is delivered as a stainless steel-version MPL. The MPL sound insulation casing can be split up and consists of 6 - 11 parts, depending on the size of the generator. The MPL capsules are also available at an extra cost for generators from 6 kW to �5 kW.
The sound insulation material is available in three different versions:“�D” - � layers, up to �5 mm thick“4DS” - up to 5 layers, up to 40 mm thick“6DS” - up to 6 layers, up to 60 mm thick
Less space required for installation
Can be installed anywhere onboard
Generator can be fitted in centre of gravity
Hermetically sealed capsule
All connections prefitted on capsule
Super-Silent Sound Insulation System
Even a very small current can have a destructive effect. Therefore, Fischer Panda uses for all Panda generators from �.� kW upwards, a dual-circuit cooling system. The engine and generator are cooled by freshwater. Seawater only comes into contact with the heat exchanger, which is manufactured from a top quality alloy (CuNi10Fe).
Water-cooled
Complete Program
AC Marine Generators
DC Marine Generators
Representatives Worldwide
Distributors Worldwide
Service Stations Worldwide
Reliable
Voltage Stability
High Performance
Water-cooled
Compact - Lightweight - Quiet
Super-silent
Compact, Lightweight and Quiet
4 5
For more than ten years, Fischer Panda Generators have used their own patented electronic Voltage Control System (VCS) for controlling the generator and engine. The engine speed is progressively controlled. This ensures that the output voltage of the asynchronous generator has a tolerance of ± �V. The Panda combines
all the advantages of the asynchronous generator with the voltage control of a synchronous generator.
The HP1 is the standard version for ��0V AC 50 Hz, (1�0 / �40V - 60 Hz). This is available up to �5 kW. From 1� kW, a three-phase version should be considered, as the Panda generator permits dissymmetrical loads up to 50% per phase.A check should always be made as to whe-ther a DC-AC Power System would be the better solution (see DAPS DC-AC Power System) for small to middle range on-board power systems.
230V - 50 Hz AC or120V / 240V - 60 Hz
400V - 50 Hz AC or208V - 60 Hz AC
The “DVS” Combi-Winding is a special version consisting of two separate coils without the additional cost. A 400V three-phase winding is combined with a single-phase winding. This permits the use of three-phase motors such as water-making units and diving compressors. The separate one-phase winding can supply the full nominal performance of the generator without “dissymmetrical load pro-blems” on a phase, which simplifies the electrical installation.
Note: Generators with DVS windings supply only 85% of the nominal performance compa-red with the HP1 or HP3 windings.
Overload protection
Water-cooled
Short-circuit stability
Monitoring and OperationThe standard version remote control panel (from Panda 6000 ND upwards) monitors the following eight functions:
Engine coolant temperature
Engine exhaust temperature
Engine oil temperature
Engine oil pressure
Battery charging
230 Volt AC
Insufficient AC voltage
Cooling-water leakage (optional)
All the benefits of the asynchronous generator and more....
Dual Voltage System (DVS) - only from Fischer Panda
The Panda offers all the advantages of the classic asynchronous generator and with the patented Voltage Control System (VCS), produces control precision that cannot be beaten by a conventional synchronous generator. The excellent qualities of the controlled Panda asynchronous generator have been impressively proven in many tests over the past years.The asynchronous generator has always set high standards with regard to operational security and operational life. Therefore, the asynchronous generator is often the compulsory choice where a high degree of safety and reliability is demanded.
Remote Control Panel for Panda 4500
Remote Control Panel for Panda 6000ND and above
Water-cooled
AC Winding available in three different versions to suit your power needs:
Voltage Stability
Single-phase winding HP1
Three-phase windings HP3
The 400V three-phase winding has the highest level of efficiency and the best qualities. This winding can also supply single-phase AC with the appropriate phase distribution. This enables each phase to be overloaded by up to 50%. A three-phase generator should always be chosen above �5 kW (from Panda �0 NE).
Panda “DVS” (Duo Voltage System) 1-phase plus 3-phase
Voltage Stability with patented Voltage Control System (VCS) Tolerance ± 3V
Reliable
The generator switches itself off when any of these functions are not in the normal state. The standard remote control panel can be upgraded with an additional automatic module to enable the generator to be started (and stopped) by external devices such as timers.
This is of particular importance for professional applications, emergency services and technical response units.Fischer Panda even warrants the rotor with a lifetime guarantee - the rotor is often the most sensitive part of other generator systems. As the components which produce the most heat are located on the stator, the asynchronous generator continues to be the best suited for water-cooling. The electrical generator is warranted with a 5-year guarantee against corrosion.
High Performance
The outstanding sine wave of the Panda generator
The Panda asynchronous generator supplies a particularly clean sine wave and has achieved the best results during numerous tests in this category. This is essential for the smooth running of sensitive electronic devices such as air conditioners, charging devices, laser printers etc.
Extremely Clean Sine Wave
Perfect sine wave
High protection rating
Precise control
No rotating coils
No diodes
No signal noise
Highly efficient
Brushless
Highest operating protection
Patented (VCS) Voltage Control System
Overload Protection
6 7
Generators for battery charging andon-board power supply
Panda Advanced Generator Technology (AGT-DDC) DC Marine Generator
Panda Advanced Generator Technology Heavy Duty (AGT-HD) DC Marine Generators
1�V / �4V / 48V DC(other voltages on request)
48V DC
Generators for on-board power supply
Fischer Panda’s innovative and integrated energy systems provide on-board power for vehicles and marine vessels without the requirement to have a permanently running generator. The extremely robust AGT Generators have proven their reliability
under extremely adverse conditions.this Fischer Panda technology impressively solves problems with independent power supplies and empty batteries. The 75 lifeboats
of the Royal Navy Lifeboat Institute are a great example of their reliability. These boats which
are equipped with Fischer Panda AGT generators, have been operating problem-free since 1997.
In order to offer optimal power solution for your marine application, we provide two main types of generators for providing on-board power.1. Panda Asynchronous Generators (PSA and PSA-HD) directly produce alternating current whilst running. These generators are ideal for continual operation.�. Permanent Magnet Generators (AGT and AGT-HD) produce direct current and function as part of
a DC-AC Power System (DAPS). A battery bank is used with an inverter within this system to supply the on-board power circuit. The level of the batteries are monitored and automatically charged by an AGT Generator. This system is optimal when power is required and the generator should not always be running.
DC-AC Power System (DAPS)
“Fast runners” - the ideal alternative up to 30 kW
The application and installation should be considered in each individual case.�000 / �600 rpm = fast-runner (Panda PSA)1500 / 1800 rpm = slow-runner (Panda PSA-HD)Low frequencies contain more energy and their energy-rich vibrations are transmitted to all components within the surrounding area. The generator is “noticeable” throughout the whole ship. A correctly installed fast-runner that is housed within an insulation capsule is quieter than a slow runner (often the opposite is presumed).Slow-runners are heavier and larger than their fast-running counterparts. As weight and space play such an important role in modern ship’s construction the fast-runner has considerable advantages.
Panda Standard Asynchronous (PSA)AC Marine Generators�000 rpm - 50 Hz - ��0V�000 rpm - 50 Hz - 400V�600 rpm - 60 Hz - 1�0 / �40V AC�600 rpm - 60 Hz - �08V AC
1500 rpm - 50 Hz - ��0V1500 rpm - 50 Hz - 400V1800 rpm - 60 Hz - 1�0 / �40V1800 rpm - 60 Hz - �08V AC
Panda Standard AsynchronousHeavy Duty (PSA-HD) AC Marine Generators
Battery12 / 24 / 48V DC
Inverter
230V / (120/240V ) AC12V / 24V DC
Frequency Converter
400V 3-phase
Professional solutions for all recreational and commercial marine applications
Reduced weight
Smaller dimensions
Reduced fuel consumption
Reduced purchase price
Complete Program
Now even better with VICTRON Energy
Reduced maintenance costs
Reduced environmental pollution
Reduced exhaust emissions
Reduced fuel consumption
Normally, a yacht’s generator is not usually used for more than 500 hours per year and therefore the question concerning an increase in engine life (exceeding 10.000 hours) is hardly relevant.The high reliability and longer life of a slow-runner is not always an important aspect because the modern diesel engine operates within its ideal speed range. This is closer to �000 / �600 revolutions per minute than 1500 / 1800.As a result of their effective water-cooling, even at higher surrounding temperatures, Panda generators can be up to �0% more efficient than other units of a comparable size.
Panda Advanced Generator Technology Diesel Electric(AGT-DE) AC Marine Generators
�40-480V AC variable speed
Generators for drive purposes and on-board power supply
Less noise onboard and outside
Longer lifespan for generator
Smaller battery bank possible
Up to 30 % smaller and lighter
Automatic start is standard AGT 4000
Automatic start as option for AGT 4000
Dual-circuit cooling as standard
8 9
ND VersionsThe Panda Generator ND version is an ideal solution for those interested in gaining a fair price. The generators are identical to the
corresponding NE models in respect of all main components, such as motor, generator, sound insulation casing, water-cooling etc. In
the case of ND generators, the electronic speed control is not fitted. The voltage tolerance lies therefore within an acceptable range of
±8 %. This is similar to a land power connection.
NE (and HD) VersionsThe Panda generator NE version has been fitted for many years with the tried and tested VCS (Voltage Control System) whereby the
motor speed is progressively controlled. This has an enormously positive effect on the exhaust emission and ensures that the generator
achieves up to 15 % more effective performance than other non-controlled generators. The VCS adjusts the voltage with a tolerance of
+/- � volts in the range up to 80 % of the nominal performance. An external AC control box contains the VCS and the capacitors which
are used for boosting the starting current. This is standard for models from Panda 4500 SCB/FCB and 5000 LPE up to 18NE.
Panda AC Marine Generators 50 Hz
KEY:EK = Single-circuit cooling (generator and engine are cooled directly with seawater)ZK = Dual-circuit cooling (generator and engine are cooled directly with fresh water)LP = Low profile (especially low construction) SC = Seawater cooling for generator und engine FC = Freshwater cooling for generator und engine B = Automatic Start Booster (ASB) for boosting start-current
The dimensions apply for the sound insulation capsule only. They do not take into consideration latches, fittings etc. Also be aware that additional room will need to be calculated for installation to include hoses, cables and capsule mountings. Additional compo-nents or alternators may also affect capsule dimensions.
Due to our policy of continual product development, we reserve the right to alter these specifications without notice. Fischer Panda GmbH reserves the right to change technical information such as performance, dimensions, weight, material specifications without prior notice. Please note that the data in this publication reflects the technical state at time of print. All performance data relates to air and water temperatures of �0°C. Performance reduction (approx. 1% per 100m height and approx �% per 5°C air temperature and approx. 1% per 1°C water temperature above �0°C)
1)2)3)
Panda Generator
Model / Type
Generator Nominal Performance
Volta
ge T
oler
ance
Coo
ling
Cap
sule
Typ
e
Soun
d In
sula
tion
Engi
ne M
anuf
actu
rer
Engi
ne T
ype
Engi
ne
Dis
plac
emen
t cm
�
Num
ber
of C
ylin
ders
Soun
d Le
vel
7m /
�m
/ 1
m (d
bA)
Cap
sule
Dim
ensi
ons
L x
W x
H (m
m)
Wei
ght i
ncl.C
apsu
le
(kg)
HP1��0V
1-phase 50 Hz
HP3400V
�-phase 50 Hz
DVS��0/400V
1- plus �-phase 50 Hz
Nominal Performance Nominal Performance Nominal Performance (kW)
kW kVA kW kVA 1-phase �-phase
A. 3000 rpm - 50 Hz Panda Marine Generators without electronic regulation
Pa
nd
a N
D
1 Panda �,8 ND PMS �,� �,8 - - - - ±8 % EK 1) GFK �D Farymann 18W �98 1 54 / 64 / 68 5�0x�65x5�5 100
� Panda 4.5 ND PMS �,8 4,5 - - - - ±8 % EK 1) GFK �D Farymann 18W �98 1 54 / 64 / 68 5�0x�65x5�5 100
� Panda 4500 SCB PMS �) �,8 4,5 �,8 4,5 �,� �,� ±8 % EK 1) GFK �D Farymann 18W �98 1 54 / 64 / 68 5�0x�65x5�5 100
4 Panda 4500 FCB PMS �) �,8 4,5 �,8 4,5 �,� �,� ±8 % ZK �) GFK �D Farymann 18W �98 1 54 / 64 / 68 5�0x�65x5�5 110
5 Panda 6000 ND PMS 5,1 6,0 5,1 6,0 - - ±8 % ZK �) GFK �D Kubota Z48� 479 � 5� / 6� / 67 595x440x590 164
6 Panda 9000 ND PMS 7,7 9,0 7,7 9,0 - - ±8 % ZK �) GFK �D Kubota D7�� 719 � 5� / 6� / 67 705x445x590 195
B. 3000 rpm - 50 Hz Panda Marine Generators with VCS Voltage Control
Pa
nd
a N
E
1 Panda 4500 SCE PMS �) �,8 4,5 �,8 4,5 �,� �,� ±� V EK 1) GFK �D Farymann 18W �98 1 54 / 64 / 68 5�0x�65x5�5 100
� Panda 5000 LPE PMS �) 4,0 4,8 4,0 4,8 �,5 �,5 ±� V ZK �) GFK �D Kubota EA�00 �09 1 54 / 64 / 68 597x5�5x407 117
� Panda 8.000 NE PMS 6,8 8,0 6,8 8,0 6,0 6,0 ±� V ZK �) GFK �D Kubota Z48� 479 � 5� / 6� / 67 595x440x590 164
4 Panda 1�.000 NE PMS 10,� 1�,0 10,� 1�,0 9,0 9,0 ±� V ZK �) GFK �D Kubota D7�� 719 � 5� / 6� / 67 705x445x590 195
5 Panda 14.000 NE PMS 11,9 14,0 11,9 14,0 10,5 10,5 ±� V ZK �) GFK �D Kubota D78� 780 � 54 / 64 / 68 740x480x600 ��9
6 Panda 18 NE PMS 15,� 18,0 15,� 18,0 1�,5 1�,5 ±� V ZK �) GFK �D Kubota D1105 11�� � 55 / 65 / 69 8�0x515x660 �97
7 Panda �4 NE PMS �0,4 �4,0 �0,4 �4,0 18,0 18,0 ±� V ZK �) GFK �D Kubota V1505 1498 4 55 / 65 / 69 1010x515x670 �55
8 Panda �0 NE PMS �5,5 �0,0 �5,5 �0,0 ��,4 ��,4 ±� V ZK �) GFK �D Kubota V1505TD 1498 4TD 55 / 65 / 69 1010x515x670 40�
9 Panda 40 YA PMS - - �5,0 41,1 - - ±� V ZK �) MPL 4DS Yanmar 4TNV84T 1995 4 57 / 67 / 71 1170x680x780 588
10 Panda 50 YA PMS - - 4�,5 50,0 - - ±� V ZK �) MPL 4DS Yanmar 4JH4TE 1995 4TD 57 / 67 / 71 1150x660x780 71�
11 Panda 65 YA PMS - - 55,� 65,0 - - ±� V ZK �) MPL 4DS Yanmar 4JH4HTE 1995 4TD 57 / 67 / 71 1�60x700x800 7�5
14 Panda 75 MB PMS - - 6�,8 77,0 - - ±� V ZK �) MPL 4DS Merc.Benz OM 60�A �.5 �000 6 57 / 67 / 71 on request on request
15 Panda 85 MB PMS - - 7�,� 85,0 - - ±� V ZK �) MPL 4DS Merc.Benz OM 60�A �.5 �000 6 57 / 67 / 71 on request on request
C. 1500 rpm - 50 Hz Panda Marine Heavy Duty Generators with VCS Voltage Control
Pa
nd
a H
D
1 Panda 7,5-4 HD PMS 6,5 7,6 ./. 4) ./. 4) - - ±� V ZK �) GFK �D Kubota D905 898 � 5� / 6� / 66 8�0x515x660 �78
� Panda 9-4 HD PMS 8,0 9,4 ./. 4) ./. 4) - - ±� V ZK �) GFK �D Kubota D 1105 11�� � 5� / 6� / 66 8�0x515x665 �94
� Panda 1�-4 HD PMS 10,5 1�,� ./. 4) ./. 4) - - ±� V ZK �) GFK �D Kubota V 1505 1498 4 5� / 6� / 66 950x515x665 �15
4 Panda 17-4 HD PMS 14,7 17,5 14,7 17,5 - - ±� V ZK �) MPL 4DS Kubota V ��0� �197 4 5� / 6� / 67 1100x6�0x780 557
5 Panda ��-4 HD PMS 18,6 �1,9 18,6 �1,9 - - ±� V ZK �) MPL 4DS Kubota V�40�M �4�4 4 5� / 6� / 67 on request on request
6 Panda �0-4 HD PMS �5,0 �9,4 �5,0 �9,4 - - ±� V ZK �) MPL 4DS Kubota V��00 ��18 4 on request 1�70x680x880 75�
7 Panda 40-4 HD PMS - - �5,0 41,1 - - ±� V ZK �) MPL 4DS Kubota V��00T ��18 4TD on request 1��0x700x900 809
8 Panda 60-4 DZ PMS - - 50,4 59,� - - ±� V ZK �) MPL 6DS Deutz BF4M�01�C 4040 4 on request 1�60x710x950 8�0
9 Panda 70-4 DZ PMS - - 61,6 7�,5 - - ±� V ZK �) MPL 6DS Deutz BF4M101�E 4764 4 on request 1540x940x940 on request
10 Panda 85-4 DZ PMS - - 7�,6 86,6 - - ±� V ZK �) MPL 6DS Deutz BF4M101�EC 4764 4 on request on request on request
11 Panda 110-4 DZ PMS - - 9�,8 109,� - - ±� V ZK �) MPL 6DS Deutz BF6M101�E 7146 6 on request on request on request
1� Panda 1�0-4 DZ PMS - - 111,� 1�0,8 - - ±� V ZK �) MPL 6DS Deutz BF6M101�EC 7146 6 on request on request on request
10 11
Paderborn
AGT 4000-1� PMS 4 �,� 1� ��0 �80 Kubota EA�00 �400-�000 �09 1 GFK �DS 595x�90x�95 90
AGT 4000-�4 PMS 4 �,� �4 110 140 Kubota EA�00 �400-�000 �09 1 GFK �DS 595x�90x�95 90
AGT 5000-1� PMS 4,5 �,6 1� �50 �80 Kubota Z48� 1800-��00 479 � GFK �DS 590x5�0x600 1�9
AGT 6000-�4 PMS 6,0 4,8 �4 170 �10 Kubota Z48� �400-��00 479 � GFK �DS 590x5�0x600 1�9
AGT 8.000-�4 PMS 8,0 6,4 �4 ��0 �80 Kubota D7�� ��00-�600 719 � GFK �DS 655x505x600 165
AGT 14.000-48 PMS 1� 10,� 48 180 ��0 Kubota D78� �400-��00 78� � GFK �DS 655x505x600 �00
AGT 15.000-48 PMS 14 11,� 48 �00 �50 Kubota D1105 �000-�800 11�� � MPL 4DS 7�5x505x660 �50
AGT 16.000-48 PMS 16 1�,8 48 ��0 �80 Kubota V1505 �000-�400 1498 4 MPL 4DS 840x505x660 �00
AGT �5.000-7� PMS �5 �0,0 7� ��0 �80 Kubota V1505TD ��00-�000 1498 4TD MPL 4DS request �40
AGT �8.000-96 PMS �8 ��,4 96 190 �40 Yanmar 4JH4-E ��00-�000 �190 4TD MPL 4DS request 500
AGT 40.000-96 PMS 40 �0,0 96 �70 �80 Yanmar 4JH4-DTE ��00-�000 1995 4TD MPL 4DS request 550
Panda 4�00 SC *) PMS 4,� n.a Farymann 18W GFK �D 5�0x�70x5�0 105
Panda 4�00 FC *) PMS 4,� n.a Farymann 18W GFK �D 5�0x�70x5�0 105
Panda 6000 PMS 6,0 n.a Kubota Z48� GFK �D 600x450x580 16�
Panda 8 Mini PMS 7,5 VCS Kubota Z48� GFK �D 600x450x580 16�
Panda 1� Mini PMS 11,5 VCS Kubota D7�� GFK �D 700x470x580 199
Panda 16 PMS 15,5 VCS Kubota D1005 GFK �D 8�0x510x670 �08
Panda �� PMS �1,6 VCS Kubota V1�05 GFK �D 940x510x670 �55
Panda 7,5-4 HD PMS 7,8 VCS Kubota D905 GFK �D 8�0x505x658 �45
Panda 09-4 HD PMS 9,6 VCS Kubota D1105 GFK �D 8�0x505x660 �84
Panda 1�-4 HD PMS 1�,6 VCS Kubota V1505 GFK �D 950x515x665 �15
Panda 17-4 HD PMS 17,6 VCS Kubota V��0� MPL 4DS 1140x6�0x800 560
Panda ��-4 HD PMS ��,� VCS Kubota F�80� MPL 4DS 1�00x6�0x780 665
Panda �0-4 HD PMS �0,0 VCS Kubota V��00 MPL 4DS 1�70x680x880 7�8
Panda 40-4 HD PMS 40,9 VCS Kubota V��00T MPL 4DS request request
Panda 60-4 DZ PMS 60,0 VCS Deutz BF4M�01�C MPL 6DS request request
Panda 70-4 DZ PMS 70,9 VCS Deutz BF4M101�E MPL 6DS request request
Panda 85-4 DZ PMS 85,9 VCS Deutz BF4M101�EC MPL 6DS request request
Panda 110-4 DZ PMS 110,7 VCS Deutz BF6M101�E MPL 6DS request request
Panda 1�0-4 DZ PMS 1�0,9 VCS Deutz BF6M101�EC MPL 6DS request request
Please note that the data in this publication reflects the technical state at time of print. Deviations within the usual tolerances are permissible. Changes that serve technological advance could be carried out without notice. All performance data relates to air and water temperatures of �5°. In the case of AGT generators, the performance, when batteries are used must be limited to the constant performance.
*) SC = Sea-water cooling for generator and engine FC = Freshwater cooling for generator and engine
Panda AC Marine Generators 60 Hz
Panda DC Marine Generators
Fischer Panda is the company to consult for your individual on-board solution.
Antigua, Australia, Austria, Bahamas, Bahrain, Bangladesh, Bermudas, Brazil,
British Virgin Islands, Caribbean, China, Croatia, Cyprus, Czech Republic, Denmark,
Dominican Republic, Estonia, Faroe Islands, France, Germany, Grand Canaries, Greece,
Greenland, Grenada, Guadeloupe, Hong Kong, Hungary, Iceland, India, Iran, Israel, Italy, Japan,
Kuwait, Latvia, Lebanon, Lithuania, Mallorca, Malta, Martinique, Netherlands, Netherlands Antilles,
New Caledonia, New Zealand, Norway, Oman, Philippines, Poland, Portugal, Russia, Singapore, South
Africa, South Korea, Spain, St. Michael, Sweden, Switzerland, Taiwan, Thailand, Turkey, Ukraine, United
Arab Emirates, United Kingdom, United States, Venezuela, West Indies
Distributors and service-stations in over 60 countries worldwide.
Representatives Worldwide
Fischer Panda GmbHOtto-Hahn-Str. 32-34 • D-33104 Paderborn Germany
Telefon +49 (0) 52 54 / 9202-0 • Telefax +49 (0) 52 54 / 9202-550E-Mail: [email protected]
www.fischerpanda.net
AGT Standard Generator with sound insulation capsule N
omin
al
Perfo
rman
ce (
kW)
Con
tinuo
usPe
rform
ance
(kW
)
Nom
inal
vol
tage
(DC
)
Con
stan
t cur
rent
Peak
cur
rent
rat
e (A
)
Engi
ne M
anuf
actu
rer
Engi
ne T
ype
Engi
ne R
evol
utio
ns
Dis
plac
emen
t cm
�
Cyl
inde
rs
Cap
sule
Typ
e
Soun
d In
sula
tion
Dim
ensi
ons
L x
W x
H (m
m)
Wei
ght i
ncl..
Cap
sule
A. 3600 rpm - 60 Hz Panda Marine Generators without electronic regulation
B. 3600 rpm - 60 Hz Panda Marine Generators with VCS Voltage Control
C. 1800 rpm - 60 Hz Panda Marine Heavy Duty Generators with VCS Voltage Control
Model Nom
inal
Perfo
rman
ce (k
W)
Volta
ge C
ontro
l
Engi
ne
Man
ufac
ture
r
Engi
ne T
ype
Cap
sule
Typ
e
Soun
d In
sula
tion
Dim
ensi
ons
L x
W x
H (m
m)
Wei
ght i
ncl.
Cap
sule
(kg)
Panda AGT Battery Charging Generators , Type AGT-DDC PMS
mar
ine_
com
bine
dSt
and:
07.
09.�
007
Fischer Panda GmbHOtto-Hahn-Str. 32-34 • 33104 Paderborn, Germany
Telefon +49 (0) 52 54 / 9202-0 • Telefax +49 (0) 52 54 / 9202-550E-Mail: [email protected]
www.fischerpanda.net
- Generators for the futureWhisperprop-System with Diesel-Electric Drive Complete drive system comprising generator and electric motor with control. The AGT-DE Generator and permanent -magnet motor are extremely efficient and compact. When combined with a Victron Power System it can completely replace the existing on-board power system.
Advanced AGT DC Battery Charging GeneratorsDiesel battery-charging generators with 1�, �4 or 48V. The “AGT” technology is available from �.5 to approx. 50 kW. Very efficient, compact and only available from Fischer Panda.
VICTRON Battery ChargersProfessional charging units in 1�, �4 and 48V DC with up to 600A. Also available as combi-units (inverter and charger).
VICTRON Inverters and Combi Units up to 12,5 kW Victron inverters are available for 1�, �4 and 48V DC. They can supply up to 1�.5 kW parallel or be switched to a �-phase system. Combi-units including high performance battery chargers are also available.
Radiators and Installation PartsAll vehicle and stationary generators are cooled either via an integrated or externally mounted DC or AC powered radiator. Solutions for specific customer requirements are possible. Installation parts for vehicle and marine generators are part of the standard product range.
Vehicle Generators - PVMV-NWith integrated water-cooled primary- and secondary silencers. Suitable for stationary operation. The PVMV-N generator is a compact, standard solution for use in vehicle applications.
Vehicle Generators PVK-U Generators housed in sound-insulated stainless steel capsules which are suitable for mounting externally beneath vehicles.
AGT-HD DC GeneratorSpecial high-technology generators. Low weight and compact dimensions. Also suited for diesel-electric drive systems. The AGT-DC Generator is fitted with an enhanced cooling system.
Vehicle Generators PVK-UKExtremely compact and quiet generators for vehicles which feature an integrated radiator. Suitable for mounting externally beneath vehicle.
Whisperprop Bow Thrusters
Complete bow thrusters with AC electric motors for performance ranges from 15 kW to 100 kW. A �-phase Panda AGT generator is required for power supply.
Marine Generators - PMSWorld famous Panda Generators with seawater-cooled heat exchanger, dual-circuit cooling and wet exhaust
AGT-DE Drive GeneratorThis generator is specifically designed for diesel-electric drive systems. High efficiency and economical running are particular characteristics of this generator.
Aziprop Shaft Saildrive
High-Performance AlternatorsCompact “High Output” alternators up to 4 kW, charging rate up to �60A at 1�V DC. Available in 1�V or �4V DC.
Battery MonitorsEasy to use and convenient battery monitoring. The charge level is displayed and prevents batteries from being unexpectedly discharged. This device can automatically start and stop the generator.