marsen catalog v6.0

Upload: seckin80

Post on 14-Apr-2018

307 views

Category:

Documents


1 download

TRANSCRIPT

  • 7/29/2019 Marsen Catalog v6.0

    1/26

  • 7/29/2019 Marsen Catalog v6.0

    2/26

  • 7/29/2019 Marsen Catalog v6.0

    3/26

    World reading company inside measuring and control

    04

    www.m

    arsen.c

    o.k

    r

    Cargo Tank Monitoring System with Pressure/Temp

    General Information

    Principle of operation

    The radar sensor gauge is the best version of radar level gauge for marine tankers which has been made based on the longtime field experience & stopless research and development. It is designed solely for measuring the distance, level, volume

    and reflectivity of liquids, pastes, slurries, and solids. Radar sensor can form part of an overfill protection system as defined

    in WHG if ordered with the the appropriate options. Radar sensor is a level metter based upon FMCW radar. It is used for

    measuring Level, Volume, distance to surface, reflectivity of liquids, pastes and slurries. Radar sensor is a newgeneration

    level meter with a wizard-driven setup, fully-potted electronic subassemblies, an online help functions. Radar sensor gauge

    safety module located in the cargo control room by means of the pressure and temp.

    The radar sensor gauge is Radar Type level transmitter using a frequency

    modulated continuous wave(FMCW) electromagnetic signal to measure the

    distance between its antenna and the cargo tank content surface(ullage).

    Frequency difference between transmitted and received wave is directly

    proportional ullage. An adapted data processing is able to be calculated. The

    micro wave signal issued from the antenna is directly processed, then we can

    obtain the distance between antenna and liquid surface(ullage).

    Application

    Ship's Radar tank gauging in storage vessels.

    Level measurement in processing vessels, reactors, blenders, scrubbers

    and mixers.

    Hygienic radar systems for distillation and purified water vessels even with

    water sprays.

    Interfaces on some special applications/liquids.

    Monitoring handling of high temperature molten products, inc metals

    minerals and coke products.

    www.marsen.co.kr

    RADAR LEVEL TRANSMITTER

    05

    www.m

    arsen.c

    o.k

    r

    CARGO-2000 (Radar Type)

    Technical Data

    Measuring rangeAccuracy(at reference conditions)

    Repeatability

    Measured value resolution

    Operating mode

    Beam angle

    Local Display

    Hazardous locations

    Ambient temperature(signal converter)

    Flange temperature

    Ingress protection(signal converter)

    Media

    Physical properties

    Dielectric constant

    Product limitations

    Process temperature

    Signal converter

    Flange system/antenna

    Gaskets

    Process temperature

    Powered by

    Protocols

    Current output

    Ex approvals

    IACS approvals

    0~40m / 0~132ftup to 20m / 66ft 2mm / 0.08

    0.5% error of measurement

    0.1mm / 0.04

    FMCW[Frequency Modulated Continuous Wave]24Ghz

    5

    Graphical LCD with to touch screen

    Intrinsically safe, zone 0, 1, 2

    Temperature classes : T6 T1

    Explosion groups : llA llC

    -40 +200 / -40+160

    -40 +200 / -40+390

    opt iona l -60 +250 / -75 +480

    lP67

    Measures all liquids and solids

    no effect on measurement results

    1.5

    liquid ammonia, liquid hydrogen, liquid helium

    unrestricted(but be aware of ambient and flange temperatures)

    stainless steel 316L

    stainless steel 316L[1.4404][standard]or 3% Molybden Mo

    FPM[Viton], Kalrez 6375[others optional]

    DIN 2501 DN 125 / PN 16[standard]

    DC 24V

    HART

    4~20mA passive

    Intrinsically safe according to ATEX

    DNV, ABS, GL, LR, BV, CCS, KR NK, RINA[pending]

  • 7/29/2019 Marsen Catalog v6.0

    4/26

    07

    www.m

    arsen.c

    o.k

    r

    06

    www.m

    arsen.c

    o.k

    r

    Cargo Tank Monitoing System with Magnetic Float CARGO-2000 (Magnetic Float Type)

    General Information Specification

    VALUE

    Detection unit

    Measuring range

    Accuracy

    Material

    Ex. Proof

    Enclosure

    Indication

    Out put

    Ambient temp

    Specific gravity

    Power

    SPECIFICATIONAlarm inside measuring range (0 to 35meter)

    Level: 0~35 meter users request

    Temp: PT100 or PT1000

    Level: 0~35 meter (or users r equest)

    Temp: basic 3 point -30 to 200 (expand available)

    Level: 10mm (option 5mm)

    Temp: +/- 1.0

    SUS 304/ SUS 316 / PTFE

    intrinsicallay safety Ex ia C T6

    IP 56 & IP 67 & IP 68

    wide lcd display

    7- segment available

    Level: 5mm indication (1mm indication option)

    Total 0 to 35,000mm

    & alarm condition display

    Temp: 3 point (more point option)

    or available 0 -999 range

    4~20mA analog signal

    RS 232 / RS 422 / RS 485 (option)

    contact output (for outer alarm)

    -25 to 75

    min 0.65 max 1.5

    AC 110/220 & 50/60Hz

    The CARGO-2000 is the best version of magnetic float level gauge for marine tankers which has been made based on thelong time field experience & stopless research and developments.

    It is a magnetic float type tank level gauge featuring an S.O.S (System One Sensor) that tank level, temperature, vapour

    pressure as well as issuing an alarm when limits are exceeded.

    This system is widely suitable for measurement and control of cargo liquid levels at crude oil tanker, coaster tanker, product

    carriers and chemical carriers etc.

    A key feature of the tank monitoring system is its easy of handling, because the sensors in the detector are flexible, it can be

    lifted up by hand without the need to enter tanks, even in the case of cargo tanks of all liquid carrier.

    All system is automatically operation and easy installation.

    Features

    Compact & cost saving design

    Reliable Reed Switch

    3 Point Temp sensor available

    Microprocessor based operating program

    Easy widely spread LCD display

    Patent product in case of sensorAll product & liquid measuring

    Application

    TANKER

    CHEMICAL TANKER

    OFFSHORE

    CRUDE OIL

    CHEMICAL

    SEA WATERFRESH WATER

    GAS STATION

    OIL or LIQUID A STORING PLACE

    FRESH WATER

    GAS STATION

    Component

    Controller

    - Wide LCD panel

    - 7-Segment available

    - Power supply

    - Signal Converter

    Barrier Cabinet

    - Intrinsically Safety Barrier

    Sensor

    - Float Level Sensor

    - Temperature sensor 3 point

    - Environmental Housing

    World reading company inside measuring and control

    www.marsen.co.kr

  • 7/29/2019 Marsen Catalog v6.0

    5/26

    09

    www.m

    arsen.c

    o.k

    r

    08

    www.m

    arsen.c

    o.k

    r

    Independent Type Cargo Tank High/Overfill Alarm System HAI-2000 (Magnetic Float/Capacitance Type)

    General Information Specification

    Magnetic Float TypeValve Specification

    Sensor type

    Sensor material

    Max pressure

    Measuring range

    Working temp

    Accuracy

    Enclosure

    Ex proof

    Contact

    Temp accuracy

    Specific gravity

    Nominal range

    single / dual / add to temp

    SUS 316

    5 Kgf/cm2

    0~2,500mm users request

    -20 ~ +150

    Level: 10mm (option 5mm)

    IP 68

    Ex ia C T6

    spst or users request

    +/- 1

    0.6 above

    95% at volume (high)

    98% at volume (overfill)

    Capacitance TypeValve Specification

    Model

    Conn. Size

    Material

    Power Supply

    Output

    Operating Temp.

    Protection

    Safety

    CLS-420

    JIS 5K 100A (standard)

    Housing-SCS13

    Flange-SUS304 or SUS316

    Sensor Probe-SUS316L/PTFE

    18 to 28 VDC

    4~20mA current loop with

    8mA-no alarm

    16mA-alarm

    AMB-25 to 70

    LIQUID-40 to 150

    IP56 over

    Ex ia C T6

    The HAI-2000 is the best version of magnetic float alarm and capacitance type for marine tankers which has been made

    based on the long time field experience & stopless research and developments. It is a magnetic float type tank high overfill

    alarm sensor featuring an stable function. This signal is connected to alarm modulator through safety barrier. The 95% of

    volume is normally for high alarm and 98% of volume is normally overfill alarm. A test lever is provided for manually functional

    test to check integrity of high level alarm system before cargo loading. In hazardous areas, this equipment should be used in

    conjunction with an intrinsically safety barrier. Generally our made other system can be add up for low costs.

    Features

    Simultaneous measurement of level alarm and high

    temperature alarm by one unit.

    Designed for all kind of liquid.

    Most advanced electric technology.

    for high reliability and durability.

    Patent product in case of sensor.

    Simple for construction.

    Certified by major certifying authorities.

    Application

    TANKER

    CHEMICAL TANKER

    LPG TANKER

    CRUDE OIL TANKER

    PRODUCT OIL TANKER

    LNG TANKER

    This systems are used for the level alarm in cargo tanks

    of all kinds of oil & chemical carriers.

    Component

    Controller

    - LED panel

    Barrier Cabinet

    - Intrinsically Safety Barrier.

    Sensor

    - Float Level Sensor/ Capacitance Level Sensor

    - Temperature sensor (Option)

    World reading company inside measuring and control

    www.marsen.co.kr

  • 7/29/2019 Marsen Catalog v6.0

    6/26

    Components of System

    11

    www.m

    arsen.c

    o.k

    r

    10

    www.m

    arsen.c

    o.k

    r

    Ballast & Draft Level Gauging System BAL-2000 (Pure Pneumatic Type)

    Principle of operationThe principle of operation is based on the measurement of the hydrostatic pressure by providing a constant low flow of air

    or neutral gas into a probe which opens at the tank bottom.

    The flow regulator is discharged through the purge mouth at the tank bottom and ensure a constant at the end of the

    sounding pipe in the tank irrespective of the supply pressure.

    Gauge saver is used for protecting the level indicator against over pressure.

    The blowing valve in sued for isolation from other channel without any influence.

    The air supply valve in used for sending the full air pressure through the signal line for cleaning purposes.

    The output pressure of this constant flow regulator (Corresponding to the hydrostatic pressure at the bottom of the

    sounding pipe) is connected to the level indicator.

    The indicator and constant flow regulator are built in interconnecting assembly ready for panel mounting.

    Features

    Liquid level of measuring depth pressure is indicated for direct r eading, and then the high precision is achieved.

    The construction is simple and the handling and maintenance is easy.

    Since no electricity is used, the explosionproof measures is not necessary.

    Included stop valve, other pressure is no need for line leakage test.

    Application

    Ballast tank remote reading

    Draft remote readingHeeling and trim remote reading

    Fuel oil tank remote reading

    Cargo oil tank remote reading

    All liquids even viscous ones

    (molasses, bitumen, etc.)

    World reading company inside measuring and control

    www.marsen.co.kr

    DOUBLE CHECK VALVE

    - MODEL : DCV-

    - Body material : Nabal brass

    - Connection size : JIS 5K or 10K Flange

    - Working pressure : Max 10 kg/cm2

    FLOW REGULATOR

    - MODEL : FRU-200

    - Body material : AL

    - Air supply : 4.5 kg/cm2

    - Flow rating : 10~80 NL/H

    - Blowing pressure : 4.5 kg/cm2

    GAUGE SAVER

    - MODEL : GSU-200

    - Body material : AL

    - Differential : Below 0.01 kg/cm2

    LEVEL INDICATOR

    - MODEL : PLG-200

    - Dimension : 144 144 55.5mm

    - Accuracy : 1.5% of Full Scale

    - Scale Range :

    - Working Temperature

    Gas : -20~65

    Fluid : -20~80

    3 WAY COCK- MODEL : MCK-200- Fluid : Air/Inert Gas- Operating Pressure : 0 to 1.0 MPa

    - Ambient and Fluid Temperature : -5 to 60(No Freezing)

    - Effective Area : 19 sqmm- Lubrication : Not Required(Use Turbine Oil Glass 1 ISO VG32, lf Lubricated)

    - Port Size : 1/4

    Specification

    VALUE

    System type

    Work temperature

    Signal pipe

    Operating air pressure rating

    Flow rating

    Range

    Accuracy

    SPECIFICATION

    one line air purge system

    -30 ~ 70

    OD 8mm

    4~7 kg/cm2

    10 ~ 80 Nl/hour

    1 to 40 meter

    0.5% os F.S(option)

    1.0% os F.S

    Air Purge Type Remote Level Gauging System

  • 7/29/2019 Marsen Catalog v6.0

    7/26

    Components of System

    13

    www.m

    arsen.c

    o.k

    r

    12

    www.m

    arsen.c

    o.k

    r

    Ballast & Draft Level Gauging System BAL-2000 (Electric/Pneumatic Type)

    Principle of operation

    Specification

    VALUE

    System type

    Work temperature

    Signal pipe

    Operating air pressure rating

    Flow rating

    Range

    Power supply

    Output

    Accuracy

    SPECIFICATION

    one line air purge system

    -30 ~ 70

    OD 8mm

    4~7 kg/cm2

    10 ~ 80 NI/hour

    1 to 40 meter

    16 to 32 VDC

    4 ~ 20mA 2 wire system

    0.5% os F.S (option)

    1.0% os F.S

    The principle of operation is based on the measurement of the hydrostatic pressure by providing a constant low flow of airor neutral gas into a probe which opens at the tank bottom.The output pneumatic signal of the modulator is fed into P/I converter and is changed to electric signal (4~20mA) in 2 wireby P/I convertor.The electric output signal(4~20mA) can be connected to C.R.T display cargo system, Digital indicator, analogue typeindicators, etc. or a combination of these system.

    FeaturesLiquid level of measuring depth pressure is indicated fordirect reading, and then the high precision is achieved.The constr uction is simple and the handlin g a ndmaintenance are easy.4~20mA output signal 2-wires.Blowing valve is select type(change over type).So blowing is very easy.Included stop valve at air purge head, other pressure isno need for line leakage test.

    ApplicationBallast tank remote readingDraft remote readingFuel oil tank remote readingAll liquids even viscous ones (molasses, bitumen, etc.)

    World reading company inside measuring and control

    www.marsen.co.kr

    P/I CONVERTER

    - MODEL : PHDH-200

    - Excitation(Calibration Voltage) : DC 24V

    - Excitation : DC 11~28V

    - Output : 4~20mA (2wire)

    - Accuracy(RSS) : 0.5% F.S

    - Compensated Temerature Range : 0~70

    - Operating Temperature Range : -20~80

    - Thermal Effect on Zero : 0.03% F.S/

    - Thermal Effect on Span : 0.03% F.S/

    ANALOGUE INDICATOR

    - MODEL : MAG-200

    - Input : 4~20mA

    - Internal resistence : 10 ohm

    - Indicating accuracy :

    High value of 1.0 Full Scale

    - Dimension : 110 110

    - Color : Black

    Air Purge Type Remote Level Gauging System

  • 7/29/2019 Marsen Catalog v6.0

    8/26

    15

    www.m

    arsen.c

    o.k

    r

    14

    www.m

    arsen.c

    o.k

    r

    Tank Level Gauging System BAL-2000 (Electric Pressure Type)

    Principle of operation Specification

    VALUE

    Principle

    Output

    Accuracy

    Supply voltage

    Material

    Measuring cell

    Explosion protection

    Operating temperature range

    SPECIFICATIONConverting hydrostatic pressure of a column of

    liquid into a level-L-proportional signal.

    4~20mA

    0.2% of F.R

    12~30V DC

    Diagram-AI2O3aluminum oxide ceramic probe

    housing-SUS 316 Seal-viton

    oil-free dry sensor

    Ex ia C T6

    -20~100

    The ceramic measuring cell is oil-free, I.e the process pressure acts directly on the rugged ceramic diaphragm of pressure

    transmitter and causes it to move by a max, 0.025mm.

    A pressure-dependent change in capacitance is measured by the electrodes in both the ceramic substrate and the

    diaphragm.

    The measuring range is determined by the thickness of this ceramic diaphragm.

    Features

    With is high electrical and mechanical stability, pressure

    transmitter fulfills all plant construction standards.

    Ceramic measuring cell-extremely resistant to overload,

    alternating loads and aggressive media.

    Support cable with hard-wearing conical seal on the

    probe tube and climatic protection in the pressure

    compensation tube.

    Potted electronics with 4-20mA output signal andintegrated overvoltage protection.

    Certified for hazardous area Ex ia C T6.

    Application

    Ballast tank remote reading

    Draft remote reading

    Fuel oil tank remote reading

    Wast waters, wells, locks, revers etc.

    World reading company inside measuring and control

    www.marsen.co.kr

  • 7/29/2019 Marsen Catalog v6.0

    9/26

    17

    www.m

    arsen.c

    o.k

    r

    16

    www.m

    arsen.c

    o.k

    r

    Pressure Monitoring System VIP-2000

    General Information Specification

    VALUESensor type

    Sensor material

    Max pressure

    Measuring range

    Working temp

    Accuracy

    Enclosure

    Ex proof

    Signal

    Gas kinds

    Display

    SPECIFICATIONCeramic (silicon) type pressure transmitter

    SUS 316L/PTFE

    up to over pressure (range X2)

    -500~500mbar (or users request)

    -20 ~+150

    F.S +/- O.5% (or users request F.S +/- 0.25%)

    IP 68 in case of housing

    Ex ia C T6

    4~20 mA analog signal

    oil/chemical

    LCD or 7-Segment display Including alarm condition

    The "Cargo Tank Ullage Space Monitoring System including High & Low Pressure Alarm" (VIP-2000) is newly required by

    IMO SOLAS 74, Chap. -2 Req. 59 become effective on 1. July 1998 for preventing serious deformation of the tank

    structure from such over/under pressure in case of P/V valve failure.

    The pressure monitoring system is designed for cargo tank & manifold pressure monitoring for any number of tanks.

    The ceramic measuring cell is very strong about environmental condition.

    Also this system can be reduce a calibration fee compared with P/V valve a period calibration because not need a separate

    that local area can be a calibration.

    Generally our made other system can be add up for low costs.

    Features

    Intrinsically safety detecting is applicable to all of

    inflammable.

    Ceramic measuring cell- extremely resistant to overload,

    alternating loads and aggressive media.

    Each sensor module pressure display

    Patent product in case of sensor

    Certified for hazardous area ex proof

    Certified by major certifying authorities

    High accurate reading vacuum and press figure

    Application

    TANKER

    CHEMICAL TANKER

    CRUDE OIL TANKER

    PRODUCT OIL TANKER

    If user's installed it's system instead of P/V valve, get in a

    profit both maintenance and cost of certificate

    System Principle

    The intrinsically safety type cargo tank vapour pressure monitoring system is intended for cargo tank pressure and vacuum

    pressure monitoring.

    The ceramic measuring cell is oil-free, ie, the precess pressure acts directly on the rugged ceramic diaphragm of pressure

    transmitter & causes it to move by a max pressure.

    The electrical signals from the pressure transmitters on deck are connected to zener barrier in the in the monitoring cabinet

    equipped with pressure alarm lamp, buzzer and pressure figure indicator in the cargo control room.

    If expanded system, have a easy expanded designed.

    World reading company inside measuring and control

    www.marsen.co.kr

  • 7/29/2019 Marsen Catalog v6.0

    10/26

    Main Component

    19

    www.m

    arsen.c

    o.k

    r

    18

    www.m

    arsen.c

    o.k

    r

    Vapour Emission & Control System VECS-2000

    General Information Specification

    System

    Press. Transmitter

    Oxygen sensor

    Main power supply - AC 110/220V, 50~60HzSystem power - DC 24V

    Air supply - 4~7 bar

    Range - 0~200mbar

    Power supply - DC 24V

    Output - 4~20mA

    Range - 0~25% O2

    Power supply - DC 24V

    Function -Accept horn, Accept flash, Test function

    This system is intended for measuring oxygen gas content analyzing the waste VOSs gas contents and manifold lines form

    Oil/Chemical Tanker.

    All tanker and chemical tanker should be install from19. May. 2005 according to IMO MSC/Cire 585.

    All necessary parts are intrinsically safety certified product.

    The Sampling Cabinet in steel case is installed on deck nearby the vapur manifolds and the controller is mounted in the

    cargo control room. (C.C.R)

    Features

    Intrinsically safety detecting is applicable to all of sensing

    zone.

    Material is reliable to secure body.

    Setting figure adjustable in factory.

    Program Operating Control (P.O.C) Type is easy install

    and small size.

    Selectable vapour oxygen contents measure.

    Another gas can be measure by sensor tip replace only(option).

    Anot her gas, pre ssur e a nd temp erat ure can be

    expanded easy.

    Offshore terminal interface function.

    Operation principle

    The system has fourth sample points and only one sample

    is directed and monitored individually through selecting

    valve at the time.

    The sa mpling cabinet has a include oxygen sensor,

    vapour pressure transmitter and nonflow sensor with

    intrinsically safety certified.

    Measuring oxygen, vapour pressure and non-flow signal

    send to controller through I.S barrier.All signal is display within wide LCD as to figure and alarm

    condition.

    If alarm is occur, controller sound a buzzer, flickering and

    external signal.

    World reading company inside measuring and control

    www.marsen.co.kr

  • 7/29/2019 Marsen Catalog v6.0

    11/26

    21

    www.m

    arsen.c

    o.k

    r

    20

    www.m

    arsen.c

    o.k

    r

    Fixed Gas Monitoring & Alarm System BGAS-2000

    Principle of operation

    The fixed gas monitoring system(BGAS-2000) is and automatically scanning Gas sampling system permanent installed for a

    number of sampling points. The BGAS-2000 are common for all sampling points, allowing the use of high quality gas

    detectors with good accuracy. A gas monitoring is taken from each sampling point in turn, according to the sampling

    sequence, and transported through the sampling pipe to the gas detectors. The sampling time for each points is individually

    adjustable corresponding to the pipe length of each sampling point. This gives an optimally short cycle time.

    The fixed gas monitoring system(BGAS-2000) is intended for detection of explosive and toxic gases in cofferdams, pipe

    tunnels, stools, ballast tanks, slop tanks and other areas adjecent to cargo tanks.

    A pump room installation is normally a separate system.

    The BGAS-2000 is designed to meet the requirements of IMO/SOLAS and classfication rules.

    Features

    Intrinsically safe sample cabinet

    Up to 48 sample points

    Expandable in the field with plug-in solenoids

    Auto and manual purge cyclesAuto shutdown and alarm on point flow failure

    Multiple remote displays on multi-drop network

    All sensor locations displayed on screen

    Application

    Sampling of the ballast tanks and void spaces in done

    by our sampling cabinet.

    The unit is powered equally by 110 or 220 VAC.

    The system is connected to ships computer network forviewing, logging and control of the system from any

    authorized computer on the network.

    World reading company inside measuring and control

    www.marsen.co.kr

    Specification

    VALUE

    Power supply

    Pump capacity

    Gas detectors

    Sampling points

    Suction pipes

    Outputs

    Installation accessories

    Option

    SPECIFICATION

    110~220 VAC (50~60Hz), 2A

    151/min

    Up to 4 pieces (HC, O2, H2S etc)

    Maximum 48 with or without counter pressure

    OD 8 or 10, ID approx. 6

    6 relays with 2 switching 5A contacts

    each standard or custom defined

    Flame traps, shut off valves, filters, cones, etc.

    Printer(RS232), NMEA protocol(RS485),

    Pre-suction pump 151/min,

    1~4 Repeater units, pump redundancy,

    other special arrangements

    Components of System

    System Example

  • 7/29/2019 Marsen Catalog v6.0

    12/26

    23

    www.m

    arsen.c

    o.k

    r

    22

    www.m

    arsen.c

    o.k

    r

    Oil Discharge Monitoring Equipment

    General Information

    The ODM-2000 has an oil discharge monitoring and control system installed, incorporating an approved oil content meter

    with a starting interlock and an automatic overboard valve control system. The system is fully intrinsically safe using optical

    fibers. Automatic cleaning is achieved by a pneumatic actuated wiper, all part in contact with the fluid are corrosion proof for

    long-life in harsh environment. A self-calibration and washing system eliminates most of the mainenance. The system is a

    high quality product and the components are designed for obtaining long lifetime in a rough environment.

    Features

    The measuring range is 0-1000ppm

    Easy to operate as it is a minimum of button to press and self explanatory menus

    Robust, easy to install and easy to maintain

    A unique self-cleaning feature, making manual cleaning virtually unnecessary.

    Intrinsically safe type, DP transmitter

    Short response time(15sec)

    Insensitive to ships motion and vibration

    Flowmeter working by differential press.

    IMO RES. MEPC. 108[49]

    Input information : PPM, Flow Rate, Ship's Speed, GPS(Latitude & Longitude), Date & Time.

    Starting interlock

    Discharge Valve Control

    Output Information(Displayed and printed) : L/N.M, Total Quantity, Date & Time, PPM, GPS(Latitude & Longitude)

    World reading company inside measuring and control

    www.marsen.co.kr

    ODM-2000

    Specification

    NAME

    Oil content

    Method of communication

    Discharge flowrate

    Log speed

    Gps

    Discharge valve

    Valve position

    VALUE

    0 to 1000ppm

    Max. 1,225m3/h

    21knots max.

    SIGNAL

    Display

    Current Loop

    4-20mA

    Impulses

    NMEA0183

    Dry contact

    Dry contact

    Controller and oil content meter power supply : 220V-60Hz or 110V-50Hz

    Motor/pump power supply : 440V-60Hz or 380V-50Hz, tree phase

    Ambient temperature : 0~+55

    roll and pitch : 22.5 respecting normal installation specifications

    Humidity : 95%RH at the most at 55

    Vibration : 2-13.2 Hz amplitude+1mm

    Input and output signals

    OIL CONTENT METER HYD. PACAGE

    CONTROLLER

  • 7/29/2019 Marsen Catalog v6.0

    13/26

    25

    www.m

    arsen.c

    o.k

    r

    24

    www.m

    arsen.c

    o.k

    r

    Temp Monitoring System

    General Information

    The TEMP-2000 has been specially developed in conformity with SOLAS 2000 Amendments Chap -2 Reg 4 amended

    for protecting the cargo pump room in tanker.

    It consists of temperature sensors, safety I.S barriers and temperature monitoring unit having digital display and alarm

    status.

    Cargo pumps, Ballast pumps and stripping pumps, installed in cargo pump rooms and driven by shift passing through

    pump room bulkheads shall be fitted with temperature sensing devices for bulkhead shaft glands, bearings and pump

    casings. The continuous and audible and visual alarm shall be automatically effected in the cargo control room or the pump

    control room.

    Our system is installed special program in temperature measuring and control only.

    If you spread or special purpose request, will be convert to fast fitted your request.

    Features

    Easy installation

    Micro processor type controller

    Long life sensor

    Digital displayHigh, Low and another setting available

    Widely strong interface function

    Most advanced electric technology for high reliability and

    durability

    Application

    The pumps temperature monitoring & alarm panel gives

    an audible, visible alarm with digital display.

    The individual external sound and visual alarm device

    may be prepare in accordance with user's requestspecial option.

    Another system like as P/R bilge alarm, gas alarm may

    be prepared with our system if user's request.

    World reading company inside measuring and control

    www.marsen.co.kr

    TEMP-2000

    Specification

    VALUESensor type

    Sensor material

    Max measuring temp

    Measuring range

    Working temp

    Accuracy

    Enclosure

    Ex proof

    Signal

    Fault

    Installation

    SPECIFICATIONRTD/ TC/ SEMICONDUCTOR

    SUS 316/VITON

    UP TO 600

    NOMINAL 0~200

    -30~ +80

    +/- 1.0 (or USERS REQUEST F.S +/-0.5 )

    IP 56 IN CASE OF HOUSING

    Ex ia C T6

    RTD/TC/or 4~20mA ANALOG SIGNAL

    LINE BREAK/SHORT MEASURING

    BEARING1, BEARING2, INTERMEDIATE BEARING

    CASING, BULKHEAD SHAFT GLAND

    FITTING MOUNTING

  • 7/29/2019 Marsen Catalog v6.0

    14/26

  • 7/29/2019 Marsen Catalog v6.0

    15/26

    Specification

    29

    www.m

    arsen.c

    o.k

    r

    28

    www.m

    arsen.c

    o.k

    r

    Valve Remote Control System

    General Information

    The VRC-2000 is designed for position indication and

    electro-hydraulic remote control of hydraulically actuated

    valves.

    The principle of the VRC-2000 is that pressurized oil,

    generated by the power pack, is used to open or close the

    valve by means of the solenoid controlled actuator.

    Our wide array of valve remote control systems includes

    hydraulic, pneumatic, electric and electro-hydraulic

    options.

    Pneumatic/Hydraulic Actuator

    Source : Pneumatic or Hydraulic

    Acting : Single or Double

    Connection : G 1/2"

    MAX press : 10BAR (Pneumatic) 350 BAR(HYD)

    MIN PRESS : 4BAR (Pneumatic) 80 BAR(HYD)

    Connection valve : Butterfly or Ball

    Indication : option -Use : Ballast Tank

    Easy to install & Simple operating.

    Fast delivery time & low price.

    At least maintenance & Long life.

    Electric actuator

    Source : AC220/110V 50/60Hz

    Valve : Butterfly of Ball

    Enclosure : IP 68

    Size : 40~100A

    Manual : Available

    Indication : Visual indication

    Use : Dry space

    World reading company inside measuring and control

    www.marsen.co.kr

    VRC-2000

    VALUE

    Certified to

    Ambient temperature

    Liquid temperature

    Protection class

    Normal voltage

    Normal current

    Measuring voltage

    SPECIFICATION

    Class Drawing

    -25 ~ +70

    -20 ~+70

    IP56, IP65, IP68

    4.6V to 30V DC

    Unswitched < 0.5A

    switched > 2.0A

    AC 110/220V

  • 7/29/2019 Marsen Catalog v6.0

    16/26

    31

    www.m

    arsen.c

    o.k

    r

    30

    www.m

    arsen.c

    o.k

    r

    Water Ingress Alarm System

    General Information

    This system comprises of alarm monitoring cabinet, Intrinsically safety Barrier and types capacitance liquid detectors

    installed in each cargo holds and compartment.

    Our model provide our customer with suitable method for new ships and existing ships.

    Features

    Intrinsically safety detection can be applicable to all of

    inflammable area, if required.

    No fault and any mechanical moving device for sensor.

    No moving part and reliable sensing system.

    A lot of any number of detecting points.

    Complete dust-proof and waterproof (IP68 - 5bar

    according to IEC 60529)

    Available for the overriding device for which the alarm

    can be de-activated.

    No electrical and mechanical corrosion.

    Easy maintenance and installation.

    Operating by microprocessor.

    Passed the EMI, EMC testing completely.

    Rules & Regulation

    SOLAS X /12 & X /13

    IMO RES MSC 145(77)

    IACS SC180

    Technical specification

    Main Power : AC 110/220V

    Emcy Power : DC 24V

    Max. detecting points : 80 points

    Ambient Temp' : -25 ~ 70

    Sensor Housing Material : SUS 316

    Accuracy : +/- 5mm available

    Sensor enclosure: IP68

    Sensor Ex. Grade : Ex ia B T4

    Indicating system: LED

    Pressure : 5 bar

    Time delay : abt 10 second (by microprocessor control)

    I.S barrier Grade : [Ex ia] C

    Overriding point : Max. 48 points

    Alarm sound : Dual type alarm sound.

    Interface & Simulation : RS 485 (422) & Simulation test

    available

    World reading company inside measuring and control

    www.marsen.co.kr

    WIA-2000

    Specification

    VALUESensor type

    Sensor material

    Max pressure

    Working temp

    Accuracy

    Enclosure

    Ex proof

    Signal

    Fault

    Level kinds

    Installation

    SPECIFICATIONPressure / Capacitance / Electrode / Float

    SUS 304 / SUS 316

    MAX 5 KG/cm2

    -10 ~ +60

    +/- 5 mm

    IP 68 in case of sensor

    Ex ia C T6

    4-20mA Analog Signal

    Line break / Short measuring / Earth

    Liquid / Coal / Sea water / Chemical / Solid etc

    Wall mounting / Penetration mounting

  • 7/29/2019 Marsen Catalog v6.0

    17/26

    33

    www.m

    arsen.c

    o.k

    r

    32

    www.m

    arsen.c

    o.k

    r

    De Watering System

    General Information

    This system (WIP-2000) is adapted in SOLAS Reg XZI/13 for Bulk Carrier, is designed and developed in compliance with

    IACS SC 180 rule requirements.

    This system is for discharging of water from ballast tank or forward dry spaces to overboard remotely.

    This system is available several method like as Electro, Pneumatic, Hydraulic operating.

    Controller

    Source : AC 110V/220V & 50/60Hz

    Material : SS400

    Function :

    1) Alarm function

    2) Valve operating function (open/close)

    3) Power fail (option)

    4) Power on/off

    5) Horn/Outdoor lamp (option)

    6) Digital or Mimic type

    Pneumatic/Hydraulic Actuator

    Source : Pneumatic or Hydraulic

    Acting : Single or Double

    Connection : BSPT 1/4"

    MAX press : 10BAR (Pneumatic) 350 BAR(HYD)

    MIN PRESS : 4BAR (Pneumatic) 80 BAR(HYD)

    Connection valve : Butterfly or Ball

    Indication : option -Use : Ballast Tank

    Easy to install & Simple operating.

    Fast delivery time & low price.

    At least maintenance & Long life.

    Hydraulic Power Pack

    Source : AC 220V/60HZ

    MAX. Prexx : 120 BAR

    Port : 2 Port

    Enclosure : IP 68

    EM'CY operating : YES (BY HAND PUMP)

    Weight : 35KG

    Option : Lock indication. Pneumatic operating

    World reading company inside measuring and control

    www.marsen.co.kr

    WIP-2000

    Electric actuator

    Source : AC110/220V 50/60Hz

    Valve : Butterfly of Ball

    Enclosure : IP 68

    Size : 40~800A

    Manual : Available

    Indication : Visual indication

    Use : Dry space

    Major Function

    F.P.T TANK Discharge

    Bosun store discharge

    Valve open/close indicating

    Direct/Reverse operation

    Another panel available

    Specification

    VALUE

    Certified to

    Ambient temperature

    Liquid temperature

    Protection class

    Normal voltage

    Normal current

    Measuring voltage

    SPECIFICATION

    Class Drawing

    -25 ~ +70

    -20 ~+70

    IP56, IP65, IP68

    4.6V to 30V DC

    Unswitched < 0.5A

    switched > 2.0A

    AC 110/220V

  • 7/29/2019 Marsen Catalog v6.0

    18/26

    35

    www.m

    arsen.c

    o.k

    r

    34

    www.m

    arsen.c

    o.k

    r

    General Information

    This system (TIN-2000) has a function monitoring and measuring for inclino and tilt by digital automatic program.

    Also this system have a function like as digital display, alarm warning, output signal, interface etc.

    This system is use for construction, ship's building, ship, offshore, crane etc.

    TIN-2000 may be match several machinery and system like as heeling control system in case of container ship, level

    gauging system in case of ship's F.O & D.O tanks etc.

    All control is automatic control by program but in case of emergency control and measuring, may be convert to manual

    mode.

    This system is prepare wide range like as 5, 30, 60, 90, 180 and user's request.

    And all direction is use for from left to right and front to rear or side to side, Its system is measuring to 16 channel basically.

    World reading company inside measuring and control

    www.marsen.co.kr

    Auto Heeling with Inclinometer System

    Specification

    Auto heeling with inclinometer system (TIN-2000-P)

    VALUE

    Sensor type

    Direction

    Measuring degree

    Display degree

    Working temp

    Accuracy

    Enclosure

    Max channel

    Output signal

    Output alarm

    Source

    Alarm setting

    SPECIFICATION

    Analog or Digital type

    All direction (basic 2 direction)

    1 , 2 , 3 , 5 , 10 and user's request.

    1 , 2 , 3 , 5 , 10 and user's request.

    -20 ~ +60

    F.S 1% (or User's request F.S 0.5%)

    IP44(controller), IP56 (horn & lamp)

    16 channel

    4~20mA Analog signal

    2 Channel contact (widely available)

    AC 110V/220V, 50~60Hz or DC 24V

    User's request (basic alarm 2 point)

    Specification

    Anti heeling with inclinometer system (TIN-2000-A)

    VALUE

    Model

    Main power

    Accuracy

    Response time

    Operating temperature

    Operating humidity

    Measuring degree

    Ingress Protection

    SPECIFICATION

    TIN-2000-AH

    AC 100~240V, 1 50/60 Hz

    1.5% F.S

    1.0 sec.

    0~45

    25~90% RH(NO CONDENSATION)

    1 , 2 , 3 and user's request.

    IP44

    VALUE

    Model

    Use voltage

    Max. current

    Casing material

    Operating temperature

    Ingress Protection

    SPECIFICATION

    TIN-2000-AL

    DC 24V

    0.480A

    SUS 304

    -25 ~50

    IP56

    Auto Heeling with Inclinometer System (TIN-2000-P)

    Anti Heeling with Inclinometer System (TIN-2000-A)

    TIN-2000

  • 7/29/2019 Marsen Catalog v6.0

    19/26

    37

    www.m

    arsen.c

    o.k

    r

    36

    www.m

    arsen.c

    o.k

    r

    Bridge Navigation Watch Alarm System (B-WATCH-2000)

    World reading company inside measuring and control

    www.marsen.co.kr

    Dead Man Alarm System (E-WATCH-2000)

    General Information

    Dead Man Alarm System is designed to monitor bridge activity and alert the master or other qualified navigators if the bridge

    becomes unattended.

    The system first alerts the officer of the watch through local alarm indication at the bridge unit and, if he is not responding,

    then alerts the master or other qualified officer.

    Our Dead Man Alarm System conforms to the requirements of IMO resolution MCS. 128(75)

    Performance standards for a Bridge Navigational Watch Alarm System (BNWAS) and the bridge class notations for "one-

    man bridge operation".

    General Information

    Dead Man Alarm System should be equipped inside the engine room. The infrared rays sensor catches the on-duty crews

    position and controller makes alarm for preventing them from nap/sleeping.

    This aims on its work for prevending crews from the nap/sleeping for safe sailing.

    This device is for neither catching the sleeping crew, nor making alarm to wake them up.

    Operation Principle

    System on/off (password protected)

    Adjust system timers(password protected)

    Audible and visual alarm indications

    Keys for sound off and acknowledge of alarms

    Selection of back-up navigator in duty

    Call back-up navigator

    Requirement

    Operating temperature : -15 to +70

    Maximum humidity : 96% no condensation

    Supply voltage : 18 - 32 VDC. 5% ripple

    Power consumption : 26W (typical)

    Printer (option)

    Type Approval by Ships Class

    Specification

    VALUE

    Size (high wide depth)

    Painting color

    Cover

    Body

    Weight

    Power supply voltage

    Sensor

    Start(Touch Screen)Alarm Buzzer

    Extensin Buzzer

    Contact point signal

    (for the alarm Panel)

    Material

    Number of input

    Number of output

    SPECIFICATION

    400 320 180(mm)

    7.5 BG 7/2

    SS400

    SS400

    8kg

    Main AC 110/220V 50/60Hz, Emcy DC 24V

    1~6points

    1point1point

    1~16point

    1point

    CONTROLLER

    SENSOR ALARM BOX

  • 7/29/2019 Marsen Catalog v6.0

    20/26

    39

    www.m

    arsen.c

    o.k

    r

    38

    www.m

    arsen.c

    o.k

    r

    World reading company inside measuring and control

    www.marsen.co.kr

    Ship's CCTV System (CCTV-2000)

    Specification

    Source : AC 220V/110V 50/60Hz

    Camera is color type basic.

    Camera indoor/outdoor type.

    Camera rotator/static type.

    Basic camera 4/8/16 installation.

    If you can install Deck marine. Should be check IP

    enclosure.

    Cable should be sore mold cable.

    Component

    O2 Analyzer (IGO-200)

    General Information

    In our supply an O2 analyzer with continous reading and alarm will be included. There will be two alarms, low and high O2

    content. The high alarm protects the tanks atmosphere against high O2 contents and the low alarm protects the unit stop

    the henerator, so the operator can adjust the equipment to correct the O2 content. When the O2 content is too high the

    inert gas purged to the atmosphere.

    Specification

    VALUE

    Size (high wide depth)

    Painting color

    Material

    Weight

    Power supply voltage

    External output signal

    Alarm point

    Signal

    O2 sensor PointRange

    SPECIFICATION

    Size (high wide depth)

    7.5 BG 7/2

    SS400

    5kg

    AC 100~240V 50/60Hz

    4~20mA(DC)

    Low & High alarm

    4~20mA(DC)

    1 or 2 points0~5, 0~10, 0~25%

    L.C.D MONITOR(16:9)

    - Source : AC 200~240V 50/60Hz- Size : 19inch

    DIGITAL VIDEO RECORDER(DVR)

    - Source : AC 200~240V 50/60Hz

    - D imension : 380 308 65(W D H)- Operating System : Embedded Linux

    - Compression : MPEG-4

    - Multiplexer Functionality : Triplex(Record, Playback,

    and Network at same time)

    CAMERA

    - Pick up Device : 1/3" Color Sony Super Had CCDII

    - Color System : PAL(811H 508V)

    NTSC(768H 494V)- Horizontal Resolution : 380tv Lines

    - Minimum Illumination : 0 Lux(20M Range) : LED ON

    : 0.1 Lux(F/1.2) : LED OFF

    - S/N Ratio : -45db 10%- Source : DC 12V

  • 7/29/2019 Marsen Catalog v6.0

    21/26

    41

    www.m

    arsen.c

    o.k

    r

    40

    www.m

    arsen.c

    o.k

    r

    World reading company inside measuring and control

    www.marsen.co.kr

    Oil Mist Detector (OMD-200)

    General Information

    Oil mist detection system adopting newest microprocessor and intrared technology was designed for detecting oil mist

    existence which may possibly happen in the air of both crank chamber of marine engine and such as environments, engine

    oil pump, purifier room and other machine rooms etc. of the vessel.

    Features

    Fast response to notify of exceeding allowable limit.

    Alarm in a potentially dangerous situation.

    Easy to installation and maintenance

    Not affected by oil condensation in the air and electrical interference.

    Specification

    VALUE

    Measurable range

    Accuracy

    Alarm contact

    Power sourceProtection degree

    SPECIFICATION

    0-2.2mg/L

    0.5%

    Free Contact

    DC 24VIP54

    Bilge Alarm System (BOA-2000)

    General Information

    The BOA-2000 is developed to get an sound & visible alarm for high level of pump room bilge well or engine room bilge well.

    This system consists of bilge alarm controller, intrinsically safety barrier and level switch.

    When the liquid level reaches a set point, a level switch or transmitter on the bilge well is acting and the alarm signal is given

    to the controller through intrinsically safety barrier.

    The audible and visual alarm on the alarm controller should be operated.

    The level switches shall be modelling into three types float type, capacitance type and displacement type.

    All sensor is reliable and strong function.

    This system can be spread up to 500 units sensor sensing.

    Generally our made other system can be add up for low costs.

    Specification

    VALUE

    Sonnection

    Set point

    Accuracy

    Max. PressureOver pressure

    Min. Sp gr

    Contact

    Signal (4~20ma)

    Enclosure

    Ex-proof

    Material

    Source

    CAPACITANCE TYPE

    PF 3/4" STND

    200 ~ 20,000mm

    5mm

    5 Bar7 Bar

    0.5

    Available

    Available

    IP 56 (option IP65)

    Ex ia C T6

    SUS304/SUS316

    4~20mA

    DISPLACEMENT TYPE

    JIS 5K 100A STND

    220~5000 mm

    8mm

    5 Bar7 Bar

    0.85

    Available

    Available

    IP 56 (option IP65)

    Ex ia C T6

    ALDC/SUS316

    MAX 250V 15A

    FLOAT TYPE

    JIS 5K 50A STND

    120~5000 mm

    5mm

    5 Bar7 Bar

    0.85

    Available

    Available

    IP 56 (option IP65)

    Ex ia C T6

    ALDC/SUS316

    MAX 250V 0.5A

  • 7/29/2019 Marsen Catalog v6.0

    22/26

    43

    www.m

    arsen.c

    o.k

    r

    42

    www.m

    arsen.c

    o.k

    r

    Valve Operating Viewer Controller

    World reading company inside measuring and control

    www.marsen.co.kr

    V-CON

    General Information

    This device can be use a control at automatic control valve like as pneumatic and electric.

    This device using purpose is control and degree like as open/close.

    Pneumatic and Electric automatic control valve controller

    Upper/Down or Rotary control.

    Source : AC 110V/220V or DC 24V

    User setting convert to easy by digital.

    Valve open/close indication.

    Temp, Press, Humidity, Flow,

    Level Vibration, Iclinometer

    Some valve control available.

    3-Way valve control available.

    Dimension : About 300 200 180mm

    Weight : About 2.0 kg

    Input

    Temp Transmitter (4-20mA)

    Temp Sensor (RTD, PT-100)Pressure Transmitter (4-20mA)

    Diff. Press Transmitter (4-20mA)

    Level Transmitter (4-20mA)

    Level Resis Transmitter (Potentio meter)

    Flow Transmitter (4-20mA)

    Vibration Transmitter (4-20mA)

    Ultrasonic Transmitter (4-20mA)

    Gas Transmitter (4-20mA)

    Magnetic Transmitter (4-20mA)

    Opto Transmitter (4-20mA)

    Output

    Contact, 4-20mA (Option), RS-232 (Option)

    Aux. Function

    P/P Reducer & Control

    E/P Converter

    Specification

    Control Fluids

    Control Target

    Ambient Temp'

    Working Voltage

    Air Press

    Components

    Aux. Function

    Output

    Option/Accessory

    ETC

    Air, Water, Oil

    Temp, Press, Level, Flow, Gas, Inclino ETC

    0~60

    AC 110/220V 50/60Hz or DC 24V

    4-7 kg/cm2 (Max. 10 kg/cm2)

    Controller, Sensor, Actuator

    Alarm, Valve Open/Close Percent

    Contact, 4-20mA(Option), RS-232(Option)

    Shelter, Digital Valve Positioner (VOV_420)

    Integration System, Actuator, Alar

    Control Valve

  • 7/29/2019 Marsen Catalog v6.0

    23/26

    Marsen Portable Gauging SystemGeneral Information

    45

    www.m

    arsen.c

    o.k

    r

    44

    www.m

    arsen.c

    o.k

    r

    Ullage Interface Detector (UTL-200) UTL-200

    World reading company inside measuring and control

    www.marsen.co.kr

    Tankers shall be provided with an effective oil/water interface detectors approved by the administration.

    And U.T.I shall be provided for a rapid and accurate determination of the oil/water interface in slop tanks and shall beavailable for use in other tanks where the separation of oil and water is effected and from which it is intended to discharge

    effluent direct to the sea.

    Features

    High accuracy & Responsibility

    Protect operator

    Prevent environmental pollution

    Easy construction

    Easy operation & Maintenance

    Operation Principle

    Detecting a change in impedance using ultra sonic

    technology.

    Measuring the different voltage according to conductivity of

    water.

    Temperature measurement is obtained by the output voltage

    of the built-in semiconductor element.

    Specification

    Accuracy of ullage, interface detection

    Indication of level divided by ullage and interface

    Tape length

    Tape graduation

    Tape resolution

    Tape accuracy

    Diameter of probe

    Minimum detectable level

    Ambient temperature range

    Temperature sensor measurement range

    Temperature measurement resolution

    Accuracy over calibration range

    Temperature reading mode

    LCD display

    Top Coupling(Connection)

    Battery

    Intrinsically safe type

    +/- 2mm

    Visible and Audible

    15M / 30M / 40M

    Metric

    1mm

    +/-3.2mm

    23mm

    10mm

    -20 to 70

    -20 to 110

    0.1

    +/-0.2 (0 to 70 )

    (Celsius)

    2 Line 16 character

    PF 2-1/4 TAP

    9Volt (Model : MN1604)

    Ex ia B T4

    SAMPLERUTL

    MODEL SPECIFICATIONAccuracy of Sensor Probe

    Tape Graduation

    Tape Resolution

    Tape Length

    Measurement Temperature Range

    Ex Grade

    2 mm

    Metric

    1mm

    10M, 15M, 20M, 30M, 35M

    -10 to 90

    Ex ia C T4

    Metric

    1mm

    10M, 15M, 20M, 30M

    O.D 8mm I.D 6mm

    15M

    1

    UTL-200

    (OIL-WATER INTERFACE

    DETECTOR)

    Tape Graduation

    Tape Resolution

    Tape Length

    2UTL-SPL-L

    (LIQUID SAMPLER)

    Hose Size

    Hose Length3

    UTL-SPL-G

    (GAS SAMPLER)

    2"(50A)

    1"(25A)4 DECK VALVE

    NO

  • 7/29/2019 Marsen Catalog v6.0

    24/26

    47

    www.m

    arsen.c

    o.k

    r

    46

    www.m

    arsen.c

    o.k

    r

    World reading company inside measuring and control

    www.marsen.co.kr

    Portable Gas Detector & Sensor

    Portable Gas Detector & Sensor

    Suction type

    Fixed Gas Sensors

    Service

    Salinity Meter (SAL-2000)

    General Information

    This salinity ppm alarm indicator developed for confirm to salinity density at fresh water generator or boiler feed water, etc.

    This device is very easy operate because made by digital programming technology. Also this device is simple a componentand has a low maintenance. All components are made for endure marine environmental condition. For insurance to user's

    trust, all product should be publish to certificate.

    Features

    High accuracy

    Easy using method

    Easy installation

    Several accessory

    Digital and Analog output available

    Pump stop / start function available

    Low price

    Easy spread function with another system

    rapidly delivery time

    Consists Of System

    1. Monitor

    LCD display key pad

    buzzer lamp

    2. Sensor cell

    3. Solenoid valve

    4. Serial interface (option)

    Application

    Boiler Cascadetonk

    Fresh Water Generator

  • 7/29/2019 Marsen Catalog v6.0

    25/26

    49

    www.m

    arsen.c

    o.k

    r

    48

    www.m

    arsen.c

    o.k

    r

    World reading company inside measuring and control

    www.marsen.co.kr

    MGO-HFO Changeover System

    General Information

    This product is Low Sulphur Fuel Oil switching equipment that prevent marine air pollution caused by ships and meet air

    pollution regulations, international maritime ship costs take up most of the fuel to ensure the reduction.Currently most of the ship to sail the oceans is used the primary fuel as the HFO (Heavy Fuel Oil), but it is being regulated to

    used the low sulfur oil fuel MGO (Marine Gas Oil) in certain areas due to sulfur dioxide (SOx) emissions regulations, these

    regulations will be strengthened in addition.

    Features

    1cSt ~ 10cSt measurable Viscosity Sensor and

    Measurement Algorithm

    Fuel oil pollution prevention, and automated

    monitoring structures obtained Low Sulphur Oil

    cooling system

    1 minute 2 temperature variations controlled Oil

    Changeover Unit to prevent thermal shock

    Integrated Control Panel and the sequence of H.M.I

    Type

    LSFO Auto Changeover Control System Model

    IMO/EU/USA/CANADA Rule SOx Discharge Restricted Area.

    Specification

    Contents

    Rated Current

    Rated Voltage

    Safety Parameter

    Wmax

    Absorption Force

    Duty Rating

    Working Pressure

    Ex Grade

    SPECIFICATION

    0.12A

    DC 12V

    Ui=13V Ii=2A Li=0mh Ci=0nF

    4~5Watt

    MIN 0.5N, MAX 1.5N

    Continuous(100%)

    160 bar, Max. 250bar(busting)

    -20~+50

    Ex Solenoid Valve (Model: HAS12)

    Specification

    Contents

    Supply Voltage

    Input Signal

    Output Voltage

    Storage

    Temperature

    Ex. Certification

    Intrinsic

    Associated

    Devices parameter

    SPECIFICATION

    AC220V

    DC24V

    DC12V

    -20 Ta +60

    [Ex ia] C

    Ui(4,6)=AC230V, Ui(1,2,3)=DC24V

    Po = 1W

    Uo = DC14V

    Io = 290mA

    Lo = 0.35mH

    Co = 450nF

    Ex Power Supply (Model: HAP12)

    Specification

    Contents

    Location of Unit

    Housing Material

    Connection

    Print Circuit Board

    Supply Voltage

    Input Signal

    Output Voltage

    Storage Temperature

    SPECIFICATION

    Safety Area

    Polycarbonate (Light Gray)

    Blade Pin Terminals

    FR-4

    DC24V

    DC 4-20mA

    Contact Point

    -20 Ta +60

    Current Signal Converter (Model: DAC420)

    General Information

    Ex Certification

    Kr Certification for Explosion Proof Equipment

    Patent application

  • 7/29/2019 Marsen Catalog v6.0

    26/26

    50

    www.m

    arsen.c

    o.k

    r

    World reading company inside measuring and control

    General InformationDPT-420 is use for the purposed of measurement for flow rate of liquid, gas, steam flow rate. It is output of the analog signal

    of DC 4-20ma measured Pressure corresponding.

    VALUE

    Supply PowerOutput Signal

    Accuracy

    Stability

    Temperature

    Ex Grade

    Max Static Pressure

    Pressure Range

    SPECIFICATION

    10~48VDC4-20mA, HART

    0.050%

    0.25%

    -30 ~ +85

    Ex ia C T5

    40 Bar

    0~0.2, 0~0.4, 0~1, 0~4, 0~10 BarD

    General Information

    Flow rate of fluid transport in marine is required the product of accuracy and reliability for a typical measurement

    requirements. Pipe to measure the flow rate in the APT-200 by inserting a pressure differential voltage and the static

    pressure generated by the average and the average differential pressure generated by the instrument to recognize the

    device so that the signal is output.VALUE

    Measuring fluid

    Material

    Size

    Temperature

    Working Pressure

    Accuracy

    repeatability

    SPECIFICATION

    Liquid, Gas, Steam Etc.

    STS316, 304

    Option : STS 316L

    100A ~ 800A

    300

    Option : -196

    20 Bar

    1.0% FS

    0.1% FS

    VALUE

    Main Power SupplyCommunication Mode

    Valve Position Resolution

    Delay Time Adjustment

    Dead Band Adjustment

    Duty Cycle (On-Off Duty)

    Type of Protection

    Degree of protection of

    enclosure

    Ambient Temperature

    Fluid temperature

    SPECIFICATION

    V1 : AC220V 60Hz, V2 : DC24VRS232, RS422

    MIN. 1/100

    1~10 SEC. (1 STEP 1SEC 0~10 STEP)

    0~20% (1 STEP 1% 0~20STEP)

    S2, Max 30 Minutes

    S4 50%

    Ex d C T4

    IP56

    -20 ~ +60

    -10 ~ +60

    Differential Pressure Transmitter (Model:DPT-420)

    Averaging Pitot Tube (Model:APT-200)

    Electro-Hydraulic Power Pack (Model:EHPP-200)

    51

    www.m

    arsen.c

    o.k

    r

    www.marsen.co.kr

    Pressure Pump

    FeaturesThe dry block principle excludes the use of oil or other liquids.

    A dry block with various diameters ensure thermal contact to sensor being tested.

    Simply place the sensor to be calibrated in the calibrator. Set the temperature.

    When stabilisation occurs, read the true temperature from the calibrator and recalibrate the sensor or system accordingly.

    VALUE

    Temperature range

    Resolution (display)

    Accuracy

    Stability

    Heating time to max

    Cooling time to min

    Thermostat test

    Well depth

    Well diameter

    Power supply

    Power consumpsion

    Operating temperature

    Dimension

    Weight

    SPECIFICATION

    30 to 650

    0.1

    1.5

    0.5

    40 min

    65 min

    Yes

    155 mm

    26 mm

    230 VAC, 50Hz

    1600 Watt

    110VAC, 60Hz

    0 to 40

    115 280 220

    Abt. 5.5 kgs

    VALUE

    Pressure media

    Pressure range

    Reference

    Test device

    Housing

    Weight

    Including accessories

    SPECIFICATION

    Air

    -1(-950mbar)... 40bar

    G 3/8 A female, with quickconnection

    G 1/4 A female, with hose(1.0m) & cup nut

    220 105 63 mm

    app. 500g

    seals, service & case

    Process

    connection

    Digital Reference Test Gauge

    VALUE

    Pressure connection

    Display

    Housing

    Power supply

    Accuracy

    Measuring range

    SPECIFICATION

    G1/4" male tread

    Multifunction LCD, 30x30mm

    D=70, L=100, H=30mmweight app. 130g

    protectin class IP68

    3 V-battery

    +/-0.5% FS +/-1 digit

    -1......(30)40 bar / 0.01

    Temperature Calibrator

    Pressure Calibrator