Wall Drill for cable 3 1/4" (83mm) from end of system and 1/2" (13mm) from top of system. WARNING: The sub-brackets for each shade tube should be mounted to support a weight of at least 300 pounds (136kg). The fasten- ers provided with the sub-brack- ets may not be appropriate for use in all applications.

TRANSCRIPT

Sivoia QEDTM

InstallationInstructions

Ceiling MountRoller Shade

Note: If installing a coupled system,

use In-Line Coupled Roller

Shade Addendum as the

primary installation guide.

Sivoia QEDTM | ceiling mount roller shade

Installation Instructions

SIVOIA QEDTM Ceiling Mount Installation Instructions 1

Tools Required:Tape Measure 1/4” Hex-Head DriverWire Cutter/Stripper LevelPliers Power Drill#2 Phillips Screwdriver

Box Contents:

Sivoia QED Roller Shade (2) Ceiling Sub-Brackets

Left and Right Side Bracket (attached)

(8) Mounting Screws (#8x1-3/4" (#8x44mm) Hex Head Screws)

(1) 7 Pin Terminal Block

(2) Extra Retaining Screws(#6x1/4" (#6x6mm) Phillips Head Screws)

(Actual Size)(Actual Size)

(2) 4” (102mm) Cable Ties

Notes:

1) For In-Line Coupled Shade Systems, begin with Sivoia QED In-Line Coupled Roller Shade Addendum, P/N 045-048. The Addendum will indicate when to use this document.

2) Complete wiring and programming information can be found in the Sivoia QED Wire and Programming Guide, P/N 045-038 or at www.lutron.com.

3) The Electronic Drive Unit (EDU) will need to be powered to complete installation.

(2) 7” (178mm) Cable Ties

SIVOIA QEDTM Ceiling Mount Installation Instructions 2

1 Match Shade to Window1 Match Shade to Window

System Width System Height

Confirm system dimensionson package label and window dimensions to verify appropriatewindow/shade combination.

1.1Package Label

System Width

Sys

tem

Hei

ght

SIVOIA QEDTM Ceiling Mount Installation Instructions 3

2 Pre-drill for Cable

Determine where to drill for cableaccess. See options below.

Cable should exit from wall, ceiling or jamb on EDU side of system.

Note: Leave 12-18" (305-457mm)of cable exposed.

WallDrill for cable 3 1/4" (83mm) from end of system and 1/2" (13mm) from top of system.

Wall

Ceiling

JambDrill for cable 1/2" (13mm) from top of system and3/4" (19mm) behind back of sub-bracket.

Jamb

2.1

CeilingDrill for cable 1 1/4" - 2" (32-51mm) from end of system and 1 1/4" - 1 3/4" (32-45mm)from back of sub-bracket.

3 Mount Sub-Brackets

SIVOIA QEDTM Ceiling Mount Installation Instructions 4

FabricAlignmentHoles

Once their position hasbeen established, mount sub-brackets usingappropriate fasteners.

3.2

3/4” 3/4”

System Width

Shade Width

WARNING:The sub-brackets for each shade tube should be mountedto support a weight of at least300 pounds (136kg). The fasten-ers provided with the sub-brack-ets may not be appropriate foruse in all applications.

Use fabric alignment holes toposition the sub-bracket rightto left. The fabric alignmentholes will line up with the out-side edge of the shade tube.

Note: Distance between fabric edge and end of system is 3/4" (19mm) per side.

Note: Fabric edge may notline up with edge of tube.

3.1(19mm) (19mm)

SIVOIA QEDTM Ceiling Mount Installation Instructions 5

4 Wire 7-Pin Terminal Block

SCALE 1:1

Strip jacket off entire lengthof exposed cable.12-18"(305-457mm)

Note: If cable exits from jambleave 2-3" (51-76mm) ofjacket on cable.

4.1

4.2

To EDUConnector

EGND (Yellow/Green)

24 VAC (Red)

24 VAC (Red/White)

MUX (Purple)

MUX (Gray)

+12 VDC (Blue)

Common (Yellow)

Wire 7-Pin terminal block(provided) to cable.

Note: SVQ-CBL-250 shown

SIVOIA QEDTM Ceiling Mount Installation Instructions 6

5 Mount Shade to Sub-Brackets

Remove retaining screwsfrom shade brackets.

5.1

Slide back of shade bracketinto slot of sub-bracket

5.2

Confirm shade bracketis fully engaged onto sub-bracket.

5.4

Route cable wires fromwall, ceiling, or jambbetween the shade bracketand sub-bracket beingcareful not to pinch wire.

5.5

Slide shade back whileswinging front of shadebracket up to hook onsub-bracket.

5.3

WARNING:Shades wider than 4ft (1.2m)require two people to install.

Note: Leave protectivewrapping on shade duringinstallation.

SIVOIA QEDTM Ceiling Mount Installation Instructions 7

6 Center and Secure Shade

Move the shadeleft or right untilcentered.

6.1

Insert and tighten retainingscrews on BOTH shadebrackets to secure theshade into position. Screwsshould be tightened down allthe way.

6.2

WARNING:After installing retainingscrews, gently push andpull on the rollershade toensure a secure installation.

WARNING:Shade is not securedto the wall during theadjustment procedure.Extreme movementfrom side-to-side maycause shade to fall.Attention should bepaid to the shadebrackets’ engagementinto the sub-bracket asside-to-side movementis not restricted at thispoint. Shades widerthan 4ft (914mm)require two people tocenter the shade.

SIVOIA QEDTM Ceiling Mount Installation Instructions 8

7 Adjust Shade Level

Confirm roller tube turnsfreely without rubbingon anything.

Turn leveling screw to raise or lower idlerside of shade untillevel.

7.1

7.3

Adjust shade projectionfrom window so that itclears any window trim orhardware when operating.

7.2

SIVOIA QEDTM Ceiling Mount Installation Instructions 9

8 Connect Terminal Blocks

Plug 7-pin terminal block on cable into EDU terminal blockattached to shade bracket

Note: EDU terminal blockclips onto shade bracketto hold connected terminal block in place.

8.1

Ensure terminal blocks are oriented as shown.

8.2

Secure terminal blockswith 7” cable tie.

8.3

Use 4” (102mm) Cable Ties to dresswires to preventthem from rubbing against shade fabric.

8.4

7” (178mm) cable tie

SIVOIA QEDTM Ceiling Mount Installation Instructions 10

9 IR Receiver Connection (if applicable)

Plug in EDU IR con-nector to remote eye connector (SV-IR).

9.1

Position IR eye whereit is not covered from view of remote control.

9.2

Ensure IR connectordoes not rub on shade.

9.3

EDU IR connector

SV-IR connector

SIVOIA QEDTM Ceiling Mount Installation Instructions 11

10 Programming Setting Limits from the EDU

Press and release the“Open Limit Button” ( ),the LED on the roller ShadeEDU will turn on steady,indicating that the EDU is in“Set Open Limit Mode”.

10.1 Press and Release theOpen Limit Button.

Steady LED

Adjust the position of theEDU to the desired OpenLimit using the adjustmentbuttons ( ).

10.2

Use the Adjustmentbuttons to move theEDU position.

The Open and Close Limits determine how far an EDU will travel. When the open button is pressed on aKeypad, IR transmitter, or CCI, the EDU will move to the Open Limit. When the close button is pressed ona keypad, IR transmitter, or CCI, the EDU will move to the Close Limit. The EDU will not move higher thanthe Open Limit or lower than the Close Limit.

Note: Setting the Open Limit lower than the Close Limit will cause the shade to move downwhen raise is pressed and up when lower is pressed.

Setting the Open Limit from the EDU

SIVOIA QEDTM Ceiling Mount Installation Instructions 12

10 Programming Setting Limits from the EDU(continued)

Press and hold the “OpenLimit Button” ( ) for 5 sec-onds, the LED on the rollershade EDU will flash for 2seconds, then go dark,indicating that the currentposition has been stored asthe Open Limit.

10.3 Press and hold theOpen Limit Buttonfor 5 seconds.

Press and release the“Close Limit Button” ( ),the LED on the roller Shade EDU will turn onsteady, indicating that theEDU is in “Set Close LimitMode”.

10.4

Setting the Open Limit from the EDU

Setting the Close Limit from the EDUPress and Release theClose Limit Button.

Steady LED

Flashing LED

SIVOIA QEDTM Ceiling Mount Installation Instructions 13

10 Programming Setting Limits from the EDU(continued)

Adjust the position of theEDU to the desired CloseLimit using the adjustmentbuttons ( ).

10.5

Use the Adjustmentbuttons to movethe EDU position.

Press and hold the “CloseLimit Button” ( ) for 5 sec-onds, the LED on the rollershade EDU will flash for 2seconds, then go dark,indicating that the currentposition has been stored asthe Close Limit.

10.6

Setting the Close Limit from the EDU

Press and hold theClose Limit Buttonfor 5 seconds.

Flashing LED

SIVOIA QEDTM Ceiling Mount Installation Instructions 14

11 Finish System Programming

The Sivoia QED shade is now installed, wired, and the OPEN/CLOSE limits for each shadehave been set.

The next step is to finish programming the system.

Use the instructions in the Wiring and Programming Guide (p/n 045-038) or the TechnicalReference Guide (p/n 367-592) and perform these four easy steps:

1. Address the system. This gives each EDU, keypad and contact closure interfacein the system a unique address number or “name”, allowing proper communicationbetween components.

2. Verify wiring of each EDU, keypad and interface using the LED feedback fromeach system component.

3. Assign shades (EDUs) to keypads, IR hand controls and/or contact closure inter-faces. Tell system which shades (EDUs) respond to which keypads and IR handcontrols and contact closure Interfaces.

4. Set and save PRESET shade positions if you desire them to be different fromthe factory defaults.

12 Troubleshooting

SymptomEDU will not move...

Solution...EDU is not powered - check EDU Power....Shade is caught on something - free shade....Shade is not assigned to keypad, IR, or CCI.

Shade does not fully open or fully close... ...Limits have been set incorrectly - refer to “setopen limit” and “set close limit” sections.

...Shade fabric is caught on something - free shade.

Fabric not level... ...Adjust using level adjustment screw....Check that brackets are mounted level....Check that fabric is tracking correctly on

the shade tube.

Fabric not centered over window... ...Center shade using center adjustment....Check that brackets are centered.

Shade does not move smoothly... ...Check for binding of shade fabric on side channels.

...Check fabric tracking.

IR controls will not operate shade.... ...IR transmitter does not have line-of-sight to IRreceiver.

...Out of range - move to within 40 feet (12m) of IRreceiver.

...EDUs not assigned to IR receiver.

...IR receiver not plugged into any EDU within range.

...Batteries are not providing power, replace them.

SIVOIA QEDTM Ceiling Mount Installation Instructions 15

Limited WarrantyLutron Shading Solutions by VIMCO offers an 8-year limited warranty for our shading systems. Please contact customer service or visit our website for a complete warranty statement.

Lutron Shading Solutions by VIMCO reservesthe right to make improvements or changes to these products without prior notice.Although every attempt is made to ensure thatthis information is accurate and up to date,please check with Lutron Shading Solutions by VIMCO to confirm product availability, the latest specifications, and suitability for your application.

These products may be covered by one ormore of the following US patents:

5,671,387; 6,100,659

and corresponding foreign patents. US and foreign patents pending.

Lutron, the Sunburst logo, and Sivoia are registered trademarks, and Sivoia QED and“Lutron controls your light” are trademarks ofLutron Electronics Co., Inc.

©2005 LUTRON Electronics Co., Inc.Printed in the U.S.A.P/N 045-046 REV. C

Technical AssistanceWORLD HEADQUARTERSLutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036United StatesTel: +1-610-282-3800Fax:+1-610-282-1243

EUROPEANHEADQUARTERSLutron EA Ltd.6 Sovereign CloseLondon, E1W 3JFUnited KingdomTel: +44-(0)20-7702-0657Fax: +44-(0)20-7480-6899

CUSTOMERSERVICE/ORDERINGUK +44-(0)20-7702-0657 – 09.00 - 18.00 GMTUSA +1-610-282-3800 – 08.00 - 20.00 EST

CUSTOMER SERVICE/[email protected]

TECHNICAL SUPPORT & SERVICESUSA +1-610-282-3800 – 24 hours/7 daysUK +44-(0)20-7702-065709.00 - 18.00 GMT

INTERNET:www.lutron.com

ADDITIONAL LUTRONSALES OFFICES:GermanyTel: +49-309-710-4590 Fax: +49-309-710-4591 FREEPHONE 00800-5887 6635

France Tel: +33-(0)1-44-70-71-86 Fax: +33-(0)1-44-70-70-97 FREEPHONE 0800-90-12-18

Spain-MadridTel: +34-91-567-84-79 Fax: +34-91-567-84-78 FREEPHONE 0900-948-944

Spain-BarcelonaTel: +34-93-496-57-42 Fax: +34-93-496-57-50 FREEPHONE 0900-948-944

Hong KongTel: +852-2104-7733 Fax: +852-2104-7633

Beijing Tel: +86-10-5877-1817Fax: +86-10-5877-1816

ShanghaiTel: +86-21-6288-1473Fax: +86-21-6288-1751

SingaporeTel: +65-6220-4666Fax: +65-6220-4333

JapanTel: +81-3-5575-8411 Fax: +81-3-5575-8420